首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 968 毫秒
1.
In this work, thermospray flame furnace atomic absorption spectrometry (TS-FF-AAS) was employed for Cu, Mn, Pb, and Zn determination in beer without any sample digestion. The system was optimized and calibration was based on the analyte addition technique. A sample volume of 300 μl was introduced into the hot Ni tube at a flow-rate of 0.4 ml min−1 using 0.14 mol l−1 nitric acid solution or air as carrier. Different Brazilian beers were directly analyzed after ultrasonic degasification. Results were compared with those obtained by graphite furnace atomic absorption spectrometry (GFAAS). The detection limits obtained for Cu, Mn, Pb, and Zn in aqueous solution were 2.2, 18, 1.6, and 0.9 μg l−1, respectively. The relative standard deviations varied from 2.7% to 7.3% (n=8) for solutions containing the analytes in the 25–50 μg l−1 range. The concentration ranges obtained for analytes in beer samples were: Cu: 38.0–155 μg l−1; Mn: 110–348 μg l−1, Pb: 13.0–32.9 μg l−1, and Zn: 52.7–226 μg l−1. Results obtained by TS-FF-AAS and GFAAS were in agreement at a 95% confidence level. The proposed method is fast and simple, since sample digestion is not required and sensitivity can be improved without using expensive devices. The TS-FF-AAS presented suitable sensitivity for determination of Cu, Mn, Pb, and Zn in the quality control of a brewery.  相似文献   

2.
As a result of the accident at the Chernobyl nuclear power plant (NPP) the environment was contaminated with spent nuclear fuel. The 236U isotope was used in this study to monitor the spent uranium from nuclear fallout in soil samples collected in the vicinity of the Chernobyl NPP. Nuclear track radiography was applied for the identification and extraction of hot radioactive particles from soil samples. A rapid and sensitive analytical procedure was developed for uranium isotopic ratio measurement in environmental samples based on double-focusing inductively coupled plasma mass spectrometry (DF–ICP–MS) with a MicroMist nebulizer and a direct injection high-efficiency nebulizer (DIHEN). The performance of the DF–ICP–MS with a quartz DIHEN and plasma shielded torch was studied. Overall detection efficiencies of 4×10–4 and 10–3 counts per atom were achieved for 238U in DF–ICP–QMS with the MicroMist nebulizer and DIHEN, respectively. The rate of formation of uranium hydride ions UH+/U+ was 1.2×10–4 and 1.4×10–4, respectively. The precision of short-term measurements of uranium isotopic ratios (n = 5) in 1 μg L–1 NBS U-020 standard solution was 0.11% (238U/235U) and 1.4% (236U/238U) using a MicroMist nebulizer and 0.25% (235U/238U) and 1.9% (236U/238U) using a DIHEN. The isotopic composition of all investigated Chernobyl soil samples differed from those of natural uranium; i.e. in these samples the 236U/238U ratio ranged from 10–5 to 10–3. Results obtained with ICP–MS, α- and γ-spectrometry showed differences in the migration properties of spent uranium, plutonium, and americium. The isotopic ratio of uranium was also measured in hot particles extracted from soil samples.  相似文献   

3.
A micro-scale flow system is proposed for on-line preconcentration of Cd, Cu, Mn, Ni and Pb in saliva samples and their determination by inductively coupled plasma optical emission spectrometry (ICP-OES). A small column containing 8 μl of AG50W-X8 resin was inserted into the flow system, assembled with capillary tubes and connected to a micro-concentric nebulizer. The elution of the analytes was performed with 3 mol l−1 HCl at a flow rate of 82 μl min−1. The ICP-OES signal acquisition program permits measurements for 5 s in the concentrated portion of the transient elution peaks. A sample volume of 1 ml was required to obtain enrichment factors of 46, 23, 17, 18 and 44 for Cd, Cu, Mn, Ni and Pb, respectively. The relative standard deviations for a 50-μg l−1 multi-analyte solution were ≤6.5%. The recoveries for Cd, Cu, Mn, Ni and Pb in digested human saliva samples were between 86 and 111%. The sample throughput was 24 h−1.  相似文献   

4.
An online hyphenation of capillary electrophoresis (CE) with inductively coupled plasma-mass spectrometry (ICP-MS) is developed, using a homemade nebulizer as the interface. The high resolution power of CE is used for the separation of metal species, whereas ICP-MS is taken for element specific detection with low detection limits. Metal species of standard solutions and real samples are separated and monitored by UV and ICP-MS. After optimization, electropherograms with high resolution were obtained, showing low detection limits around 1 μg/L (e.g. Pt-species) and very high resolution. Typical analysis times were below 22 min. Quality control aspects concerned species stability during the analytical procedure and stability of electrical current during nebulization. A possible interfering suction flow was estimated and found to be negligible. Received: 17 April 1996 / Revised: 12 June 1996 / Accepted: 20 June 1996  相似文献   

5.
As a result of the accident at the Chernobyl nuclear power plant (NPP) the environment was contaminated with spent nuclear fuel. The 236U isotope was used in this study to monitor the spent uranium from nuclear fallout in soil samples collected in the vicinity of the Chernobyl NPP. Nuclear track radiography was applied for the identification and extraction of hot radioactive particles from soil samples. A rapid and sensitive analytical procedure was developed for uranium isotopic ratio measurement in environmental samples based on double-focusing inductively coupled plasma mass spectrometry (DF-ICP-MS) with a MicroMist nebulizer and a direct injection high-efficiency nebulizer (DIHEN). The performance of the DF-ICP-MS with a quartz DIHEN and plasma shielded torch was studied. Overall detection efficiencies of 4 x 10(-4) and 10(-3) counts per atom were achieved for 238U in DF-ICP-QMS with the MicroMist nebulizer and DIHEN, respectively. The rate of formation of uranium hydride ions UH+/U+ was 1.2 x 10(-4) and 1.4 x 10(-4), respectively. The precision of short-term measurements of uranium isotopic ratios (n = 5) in 1 microg L(-1) NBS U-020 standard solution was 0.11% (238U/235U) and 1.4% (236U/238U) using a MicroMist nebulizer and 0.25% (235U/238U) and 1.9% (236U/P38U) using a DIHEN. The isotopic composition of all investigated Chernobyl soil samples differed from those of natural uranium; i.e. in these samples the 236U/238U ratio ranged from 10(-5) to 10(-3). Results obtained with ICP-MS, alpha- and gamma-spectrometry showed differences in the migration properties of spent uranium, plutonium, and americium. The isotopic ratio of uranium was also measured in hot particles extracted from soil samples.  相似文献   

6.
A method for the preconcentration and speciation of chromium was developed. On-line preconcentration and determination were obtained using inductively coupled plasma optical emission spectrometry (ICP-OES) coupled with flow injection. To determinate the chromium (III) present in parenteral solutions, chromium was retained on activated carbon at pH 5.0. On the other hand, a step of reduction was necessary in order to determine total chromium content. The Cr(VI) concentration was then determined by difference between the total chromium concentration and that of Cr(III). A sensitivity enrichment factor of 70-fold was obtained with respect to the chromium determination by ICP-OES without preconcentration. The detection limit for the preconcentration of 25 ml of sample was 29 ng l−1. The precision for the 10 replicate determinations at the 5 μg l−1 Cr level was 2.3% relative standard deviation, calculated with the peak heights. The calibration graph using the preconcentration method for chromium species was linear with a correlation coefficient of 0.9995 at levels near the detection limits up to at least 60 μg l−1. The method can be applied to the determination and speciation of chromium in parenteral solutions.  相似文献   

7.
The effects of nitric acid concentration and liquid flow rate on the signals obtained with an inductively coupled plasma mass spectrometer, operated with a microconcentric nebulizer (MCN-100), have been studied by the use of partial least squares regression. Thirteen elements, covering the mass range 51–238, were studied. The nitric acid concentration was varied in the range 0.14–2.8 mol l−1 and the acid effect was found to vary significantly between the elements — depending mainly on the value of the first ionisation potential of the element. The effect of the liquid flow rate was studied within the range 34.5–172.5 μl min−1 and it was only significant (P=0.05) for 107Ag and 109Ag. It is possible to compensate completely for the acid matrix effect by the use of a proper internal standard. The use of multivariate analysis methods, e.g. partial least squares regression is recommended in order to choose the most suitable internal standards.  相似文献   

8.
Different nebulizer/expansion chamber combinations were evaluated to assess their performance for sample introduction in the direct coupling with an axial view inductively coupled plasma multielement spectrometer for on-line determination of As and Se species previously separated by ion exchange–high performance liquid chromatography. The column effluents were injected into the plasma without prior derivatization. The instrument operation software was adapted for data acquisition and processing to allow multi-wavelength recording of the transient chromatographic peaks. After optimization of the chromatographic operating conditions, separation of mixtures of inorganic As and Se species, and of inorganic and two organic As species (monomethylarsonic and dimethylarsinic acids), was achieved with excellent resolution. Species discrimination from mixtures of As and Se oxyanions was further improved by the simultaneous element detection at specific analytical wavelengths. Three nebulizers and three spray chambers, employed in seven combinations, were tested as interfaces. Concentric nebulizers associated to a glass cyclonic chamber appear most suitable regarding sensitivity and signal to noise ratio. Measured element detection limits (3 σ) were around 10 ng ml 1 for all the species considered, making the method a viable alternative to similar procedures that employ volatile hydride generation previous to sample injection into the plasma. Analytical recoveries both for inorganic and organic species ranged between 92 and 107%. The method was demonstrated to be apt for the analysis of surface waters potentially subjected to natural contamination with arsenic.  相似文献   

9.
A method has been developed for the direct simultaneous determination of Cd and Pb in white and red wine by electrothermal atomic absorption spectrometry (ET-AAS) using a transversely heated graphite tube atomizer (THGA) with longitudinal Zeeman-effect background correction. The thermal behavior of both analytes during pyrolysis and atomization stages were investigated in 0.028 mol l−1 HNO3 and in 1+1 v/v diluted wine using mixtures of Pd(NO3)2+Mg(NO3)2 and NH4H2PO4+Mg(NO3)2 as chemical modifiers. With 5 μg Pd+3 μg Mg as the modifiers and a two-step pyrolysis (10 s at 400°C and 10 s at 600°C), the formation of carbonaceous residues inside the atomizer was avoided. For 20 μl of sample (wine+0.056 mol l−1 HNO3, 1+1, v/v) dispensed into the graphite tube, analytical curves in the 0.10–1.0 μg l−1 Cd and 5.0–50 μg l−1 Pb ranges were established. The characteristic mass was approximately 0.6 pg for Cd and 33 pg for Pb, and the lifetime of the tube was approximately 400 firings. The limits of detection (LOD) based on integrated absorbance (0.03 μg l−1 for Cd, 0.8 μg l−1 for Pb) exceeded the requirements of Brazilian Food Regulations (decree #55871 from Health Department), which establish the maximum permissible level for Cd at 200 μg l−1 and for Pb at 500 μg l−1. The relative standard deviations (n=12) were typically <8% for Cd and <6% for Pb. The recoveries of Cd and Pb added to wine samples varied from 88 to 107% and 93 to 103%, respectively. The accuracy of the direct determination of Cd and Pb was checked for 10 table wines by comparing the results with those obtained for digested wine using single-element ET-AAS, which were in agreement at the 95% confidence level.  相似文献   

10.
A new and sensitive method for Cd and Pb determinations, based on the coupling of thermospray flame furnace atomic absorption spectrometry and a preconcentrator system, was developed. The procedure comprised the chelating of Cd and Pb with ammonium pyrrolidinedithiocarbamate with posterior adsorption of the chelates on a mixture (40 mg) of C60 and C70 at a flow rate of 2.0 ml min−1. These chelates were eluted from the adsorbent by passing a continuous flow of ethanol (80% v/v) at 0.9 ml min−1 to a nickel tube placed in an air/acetylene flame. After sample introduction into the tube by using a ceramic capillary (0.5 mm i.d.), the analytical signals were registered as peak height. Under these conditions, improvement factors in detectability of 675 and 200 were obtained for Cd and Pb, respectively, when compared to conventional flame atomic absorption spectrometry. Spiked samples (mineral and tap waters) and drinking water containing natural concentrations of Cd were employed for evaluating accuracy by comparing the results obtained from the proposed methodology with those using electrothermal atomic absorption spectrometry. In addition, certified reference materials (rye grass, CRM 281 and pig kidney, CRM 186) were also adopted for the accuracy tests. Due to the good linearity ranges for Cd (0.5–5.0 μg l−1) and Pb (10–250 μg l−1), samples with different concentrations could be analyzed. Detection limits of 0.1 and 2.4 μg l−1 were obtained for Cd and Pb, respectively, and RSD values <4.5% were observed (n=10). Finally, a sample throughput of 24 determinations per hour was possible.  相似文献   

11.
The species of Cr(III) and Cr(VI) in water samples were determined by flow injection on-line preconcentration and separation on two-microcolumn system-derivative flame atomic absorption spectrometry during a collaborative analysis for certification. The Cr(III) and Cr(VI) in water samples were retained on two microcolumns with ion exchange resin and were eluted directly to nebulizer by 15% HNO3 and 8% NH4NO3, respectively. The characteristic concentration (at the sensitivity grade of 2 mV min?1 for 1 min of preconcentration time) for Cr(III) and Cr(VI) were 0.130 and 0.0985 μg l?1, in the order which were 332- and 431-fold better than those of FAAS, and 45- and 47-fold better than those of FI-FAAS, respectively. The relative standard deviations were 3.27% and 3.66% with corresponding detection limits (3σ) of 0.244 and 0.235 μg l?1, respectively. The linear ranges of determinations for Cr(III) and Cr(VI) were 0~100 μgm l?1 with correlation coefficients of 0.9984 to 0.9996. The satisfactory recovery of 94.4%~106% for Cr(III) and Cr(VI) could be obtained from water samples.  相似文献   

12.
Methods for the atomic fluorescence spectrometric (AFS) determination of total arsenic and arsenic species in wines based on continuous flow hydride generation (HG) with atomization in miniature diffusion flame (MDF) are described. For hydride-forming arsenic, l-cysteine is used as reagent for pre-reduction and complexation of arsenite, arsenate, monomethylarsonate and dimethylarsinate. Concentrations of hydrochloric acid and tetrahydroborate are optimized in order to minimize interference by ethanol. Procedure permits determination of the sum of these four species in 5–10-fold diluted samples with limit of detection (LOD) 0.3 and 0.6 μg l 1 As in white and red wines, respectively, with precision between 2% and 8% RSD at As levels within 0.5–10 μg l 1.Selective arsine generation from different reaction media is used for non-chromatographic determination of arsenic species in wines: citrate buffer at pH 5.1 for As(III); 0.2 mol l 1 acetic acid for arsenite + dimethylarsinate (DMA); 8 mol l 1 HCl for total inorganic arsenic [As(III) + As(V)]; and monomethylarsonate (MMA) calculated by difference. Calibration with aqueous and ethanol-matched standard solutions of As(III) is used for 10- and 5-fold diluted samples, respectively. The LODs are 0.4 μg l 1 for As(III) and 0.3 μg l 1 for the other three As species and precision is within 4–8% RSDs.Arsenic species in wine were also determined by coupling of ion chromatographic separation on an anion exchange column and HG-flame AFS detection. Methods were validated by means of recovery studies and comparative analyses by HG-AFS and electrothermal atomic absorption spectrometry after microwave digestion. The LODs were 0.12, 0.27, 0.15 and 0.13 μg l 1 (as As) and RSDs were 2–6%, 5–9%, 3–7% and 2–5% for As(III), As(V), MMA and DMA arsenic species, respectively. Bottled red and white wines from Bulgaria, Republic of Macedonia and Italy were analyzed by non-chromatographic and chromatographic procedures and the As(III), arsenite, has been confirmed as major arsenic species.  相似文献   

13.
A method for determination of inorganic and total mercury by flow injection-cold vapor atomic absorption spectrometry (FI-CVAAS) with on-line oxidation was developed. Potassium peroxodisulphate and sulphuric acid were used as oxidizing agents so that decomposition of organomercury compounds could be achieved. Depending on the temperature selected, inorganic or total mercury could be determined with the same FI manifold. In order to assess the method performance, synthetic wastewater, wastewater, urine and saline water samples were spiked with inorganic mercury, methylmercury and phenylmercury. Quantitative recoveries were obtained for the three mercury species, except with the synthetic wastewater when the chemical oxygen demand value was higher than 1000 mg l−1. In most cases, the standard addition method was usually needed for calibration. LODs calculated as 3 σ/m were 0.47 μg l−1 for inorganic mercury and 0.45 μg l−1 for total mercury. R.S.D. values corresponding to peak height measurements were 1.5 and 2.2% for inorganic mercury and total mercury, respectively. The accuracy of the method was tested by analyzing 5 mol l−1 hydrochloric acid extracts of seven biological and environmental CRMs. LODs in the solid CRMs ranged from 0.032 to 0.074 μg g−1.  相似文献   

14.
A method for the determination of molybdenum in whole blood by atomic absorption spectrometry with electrothermal atomization was developed and evaluated. Erbium (25 μg) was chosen from several potential chemical modifiers (Sm, Lu, Ho, Eu and Pd+Mg) as the most appropriate for the sensitive and reliable determination of molybdenum in such sample. The process used was direct dilution of the sample in a ratio 1:2 with a 0.1% (v/v) Triton X-100 solution. The injection of 20 μl of a solution of 15% (w/v) hydrogen peroxide and running the temperature program after 5 firings greatly reduced the effect of build-up of carbonaceous residues within the atomizer. The limit of detection and working ranges, respectively, were 0.6 and 2.0–100.0 μg l−1, and the characteristic mass was 7.2 pg. The relative standard deviation varied from 0.8 to 1.5% for within and between batch determinations, respectively. The determination of molybdenum in Seronorm™ Trace Elements in Whole Blood with known added amounts of the analyte was performed to asses the accuracy. The optimized procedure has been applied to the determination of molybdenum in whole blood specimens of 20 subjects taken before and 10–12 h after receiving an over-supply of 1 mg of molybdenum. The molybdenum concentrations (±S.D.) were 10.9±0.4 μg Mo l−1 (range 9.9–11.6 μg Mo l−1) and 15.4±0.4 μg Mo l−1 (range 13.1–16.9 μg Mo l−1) for the individuals before and after the administration of molybdenum.  相似文献   

15.
An extended study of different sampling introduction approaches using inductively coupled plasma mass spectrometry (ICP-MS) is presented for the determination of boron in steel samples. The following systems for sample introduction were applied: direct sample solution nebulization by continuous nebulization (CN) using a cross-flow nebulizer and with flow injection (FI), applied to 0.1% (m/v) and 0.5% (m/v) sample solutions, respectively; FI after iron matrix extraction, using acetylacetone–chloroform, and isotopic dilution (ID) analysis as the calibration method; FI with on-line electrolytic matrix separation; and spark ablation (SA) and laser ablation (LA) as solid sampling techniques. External calibration with matrix-matching samples was used with CN, SA, and LA, and only acid solutions (without matrix matching) with FI methods. When FI was directly applied to a sample solution, the detection limit was of 0.15 μg g−1, improving by a factor of 4 that was obtained from the CN measurements. Isotopic dilution analysis, after matrix removal by solvent extraction, made it possible to analyse boron with a detection limit of 0.02 μg g−1 and, with the on-line electrolytic process, the detection limit was of 0.05 μg g−1. The precision for concentrations above 10 times the detection limit was better than 2% for CN, as well as for FI methods. Spark and laser ablation sampling systems, avoiding digestion and sample preparation procedures, provided detection limits at the μg g−1 levels, with RSD values better than 6% in both cases. Certified Reference Materials with B contents in the range 0.5–118 μg g−1 were used for validation, finding a good agreement between certified and calculated values.  相似文献   

16.
Selective sorption of the Sb(III) chelate with ammonium pyrrolidine dithiocarbamate (APDC) on a microcolumn packed with C16-bonded silica gel phase was used for the determination of Sb(III) and of total inorganic antimony after reducing Sb(V) to Sb(III) by l-cysteine. A flow injection system composed of a microcolumn connected to the tip of the autosampler was used for preconcentration. The sorbed antimony was directly eluted with ethanol into the graphite furnace and determined by AAS. The detection limit for antimony was significantly lowered to 0.007 μg l−1 in comparison to 1.7 μg l−1 for direct injection GFAAS. This procedure was applied for speciation determinations of inorganic antimony in tap water, snow and urine samples. For the investigation of long-term stability of antimony species a flow injection hydride generation atomic absorption spectrometry with quartz tube atomization (FI HG QT AAS) and GFAAS were used for selective determination of Sb(III) in the presence of Sb(V) and total content of antimony, respectively. Investigations on the stability of antimony in several natural samples spiked with Sb(III) and Sb(V) indicated instability of Sb(III) in tap water and satisfactory stability of inorganic Sb species in the presence of urine matrix.  相似文献   

17.
This paper describes the development and design of a new, efficient, simple and robust interface for coupling capillary electrophoresis (CE) with inductively coupled plasma-mass spectrometry. The interface is based on a modified microconcentric nebulizer which permits a low flow rate of about 6 μL/min in the free aspiration mode. This interface construction provides an electrical connection for stable electrophoretic separations and adapts the flow rate of the electro-osmotic flow inside the CE capillary to the flow rate of the nebulizer for efficient transport of the analytes into the plasma. By optimization of the fluid mechanical properties the interface prevents the nebulizer from causing any laminar flow in the CE capillary and thus the high resolution power of CE can be preserved. Furthermore, this new device permits independent optimization of the nebulization from the CE whereby exact positioning of the CE capillary is not necessary, thus enabling fast exchange. A low dead volume spraychamber has been constructed which circumvents any band broadening of the sharp CE signals. Peak widths down to 3.5 s comparable to CE with UV detection are possible. Received: 5 February 1999 / Revised: 21 April 1999 / Accepted: 23 April 1999  相似文献   

18.
This paper describes the development and design of a new, efficient, simple and robust interface for coupling capillary electrophoresis (CE) with inductively coupled plasma-mass spectrometry. The interface is based on a modified microconcentric nebulizer which permits a low flow rate of about 6 μL/min in the free aspiration mode. This interface construction provides an electrical connection for stable electrophoretic separations and adapts the flow rate of the electro-osmotic flow inside the CE capillary to the flow rate of the nebulizer for efficient transport of the analytes into the plasma. By optimization of the fluid mechanical properties the interface prevents the nebulizer from causing any laminar flow in the CE capillary and thus the high resolution power of CE can be preserved. Furthermore, this new device permits independent optimization of the nebulization from the CE whereby exact positioning of the CE capillary is not necessary, thus enabling fast exchange. A low dead volume spraychamber has been constructed which circumvents any band broadening of the sharp CE signals. Peak widths down to 3.5 s comparable to CE with UV detection are possible. Received: 5 February 1999 / Revised: 21 April 1999 / Accepted: 23 April 1999  相似文献   

19.
A low flow, parallel path Mira Mist CE nebulizer designed for capillary electrophoresis (CE) was evaluated as a function of make-up solution flow rate, composition, and concentration, as well as the nebulizer gas flow rate. This research was conducted in support of a project related to the separation and quantification of cobalamin (vitamin B-12) species using microseparation techniques combined with inductively coupled plasma mass spectrometry (ICP-MS) detection. As such, Co signals were monitored during the nebulizer characterization process. Transient effects in the ICP were studied to evaluate the suitability of using gradients for microseparations and the benefit of using methanol for the make-up solution was demonstrated. Co signal response changed significantly as a function of changing methanol concentrations of the make-up solution and maximum signal enhancement was seen at 20% methanol with a 15 μl/min flow rate. Evaluation of the effect of changing the nebulizer gas flow rates showed that argon flows from 0.8 to 1.2 l/min were equally effective. The Mira Mist CE parallel path nebulizer was then evaluated for interfacing capillary microseparation techniques including capillary electrophoresis (CE) and micro high performance liquid chromatography (μHPLC) to inductively coupled plasma mass spectrometry (ICP-MS). A mixture of four cobalamin species standards (cyanocobalamin, hydroxocobalamin, methylcobalamin, and 5′ deoxyadenosylcobalamin) and the corrinoid analogue cobinamide dicyanide were successfully separated using both CE-ICP-MS and μHPLC-ICP-MS using the parallel path nebulizer with a make-up solution containing 20% methanol with a flow rate of 15 μl/min.  相似文献   

20.
There is demonstrated interest in combining capillary electrophoresis (CE) with inductively coupled plasma mass spectrometry (ICP-MS) for speciation determinations. When self-aspirating nebulizers are used for this application, it is important to offset the suction effect to avoid degradation of the separation. In this study, sample uptake rates for three microconcentric nebulizers of the same model, in combination with a cyclonic spray chamber, were characterized and compared for future utilization in CE–ICP-MS interfaces. The specific model studied was a MicroMist with a nominal uptake rate of 100 μl/min at 1 l/min argon gas flow rate per the manufacturer's specifications. Sample uptake rates at various nebulizer gas flows were measured by aspirating water from a weighed container and calculating the uptake rate in microliter per minute. The nebulizers studied provided good reproducibility from day to day, but a comparison of the different nebulizers reflected a significant difference in performance. A characteristic observed during the study was that uptake rates decreased with increasing nebulizer gas flow. This can be used for sample introduction for CE–ICP-MS. Interestingly, very different performance was observed when comparing the three different nebulizers of the same model. Uptake rates showed strong dependence on argon gas flow rates and the dimensions of the sample uptake tubing.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号