首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The main challenges in the manufacture of composite materials are low surface energy and the presence of silicon‐containing contaminants, both of which greatly reduce surface adhesive strength. In this study, carbon fiber (CF) and E‐glass epoxy resin composites were surface treated with the Accelerated Thermo‐molecular adhesion Process (ATmaP). ATmaP is a multiaction surface treatment process where tailored nitrogen and oxygen functionalities are generated on the surface of the sample through the vaporization and atomization of n‐methylpyrrolidone solution, injected via specially designed flame‐treatment equipment. The treated surfaces of the polymer composites were analyzed using XPS, time of flight secondary ion mass spectrometry (ToF‐SIMS), contact angle (CA) analysis and direct adhesion measurements. ATmaP treatment increased the surface concentration of polar functional groups while reducing surface contamination, resulting in increased adhesion strength. XPS and ToF‐SIMS showed a significant decrease in silicon‐containing species on the surface after ATmaP treatment. E‐glass composite showed higher adhesion strength than CF composite, correlating with higher surface energy, higher concentrations of nitrogen and C?O functional groups (from XPS) and higher concentrations of oxygen and nitrogen‐containing functional groups (particularly C2H3O+ and C2H5NO+ molecular ions, from ToF‐SIMS). Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

2.
Polypropylene (PP) is used in many automotive applications where good paint adhesion is of primary importance. PP is widely known for its low surface energy which impacts negatively on its adhesion strength. PP surfaces were modified using a new industrial surface‐treatment process known as the Accelerated Thermo‐molecular adhesion Process (ATmaP). ATmaP grafts functional groups to the polymer surface derived from an atomised and vapourised nitrogen‐containing coupling agent. The surface properties and adhesion performance of PP samples treated using the ATmaP process and two different flame processes were compared using XPS, time‐of‐flight secondary ion mass spectrometry (ToF‐SIMS) and mechanical testing (pull‐up tests). The latter showed that ATmaP improved adhesion strength significantly in comparison with conventional flame treatments. XPS showed an increase in oxygen and nitrogen concentration on the surface of ATmaP‐treated samples compared with untreated and flame‐treated samples. Principal components analysis (PCA) of the ToF‐SIMS data revealed the major phenomena occurring during the surface treatment of PP samples. Early stage events, including the chain scission of the PP backbone chain and the subsequent reaction of these chains with the surrounding air, are captured by the first principal component (PC1). The increase in the concentration of NO surface functional groups resulting from ATmaP treatment is captured by the second principal component (PC2). Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

3.
This report provides detailed experimental results of thermal and surface characterization on untreated and surface‐treated halloysite nanotubes (HNTs) obtained from two geographic areas. Surface characterization techniques, including XPS and time‐of‐flight secondary ion mass spectrometry (ToF‐SIMS) were used. ToF‐SIMS surface analysis experiments were performed with both atomic and cluster ion beams. Higher ion yields and more high‐mass ions were obtained with the cluster ion beams. Static ToF‐SIMS spectra were analyzed with principal component analysis (PCA). Morphological diversities were observed in the samples although they mainly contained tubular structures. Thermogravimetric data indicated that aqueous hydrogen peroxide solution could remove inorganic salt impurities, such as alkali metal salts. The amount of grafting of benzalkonium chloride of HNT surface was determined by thermogravimetic analysis. PCA of ToF‐SIMS spectra could distinguish the samples mined from different geographical locations as well as among surface‐treated and untreated samples. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

4.
Electropolymerization of pyrrole‐3‐acetic acid was performed by cyclic voltammetry on titanium and Ti90Al6V4 substrates with the aim of developing a multilayer structure for applications in advanced biomaterials. The polymeric films obtained were characterized by both XPS and time‐of‐flight secondary ion mass spectrometry (ToF‐SIMS). Information on the poly(pyrrole‐3‐acetic acid) (PPy‐3‐acetic) surface structure was achieved by a detailed XPS analysis of C 1s and N 1s signals. The number of COOH groups was quantified by XPS coupled to a chemical derivatization reaction in which esterification with trifluoroethanol was exploited so that the presence of fluorine (or the CF3 component in C 1s spectra) could be used as a marker for COOH groups. As a result, it was found that more than 90% of the monomer units along PPy‐3‐acetic chains bear carboxylic functionalities, of which 60% are protonated and 40% are present as carboxylate groups. Some decarboxylation occurs with film ageing. The PPy‐3‐acetic films were also investigated by ToF‐SIMS in the negative ion mode, thus obtaining, for the first time, interesting information on the structure of the top surface layers of a polymer belonging to the polypyrrole family. In particular, clusters of peaks related to PPy‐3‐acetic oligomers were detected and the decarboxylation phenomenon on top of the polymer surface was confirmed. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

5.
Poly(styrene) (PS), poly(2,3,4,5,6‐pentafluorostyrene) (5FPS) and their random copolymers were prepared by bulk radical polymerization. The spin‐cast polymer films of these polymers were analyzed using X‐ray photoelectron spectroscopy (XPS) and time‐of‐flight secondary ion mass spectrometry (ToF‐SIMS). The surface and bulk compositions of these copolymers were found to be same, implying that surface segregation did not occur. The detailed analysis of ToF‐SIMS spectra indicated that the ion fragmentation mechanism is similar for both PS and 5FPS. ToF‐SIMS quantitative analysis using absolute peak intensity showed that the SIMS intensities of positive styrene fragments, particularly C7H7+, in the copolymers are higher than the intensities expected from a linear combination of PS and 5FPS, while the SIMS intensities of positive pentafluorostyrene fragments are smaller than expected. These results indicated the presence of matrix effects in ion formation process. However, the quantitative approach using relative peak intensity showed that ion intensity ratios are linearly proportional to the copolymer mole ratio when the characteristic ions of PS and 5FPS are selected. This suggests that quantitative analysis is still possible in this copolymer system. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

6.
A series of 2,2‐bis(hydroxymethyl)propionic acid (Bis‐MPA) hyperbranched aliphatic polyesters with different molecular weights (generations) is analysed for the first time by time‐of‐flight secondary ion mass spectrometry (ToF‐SIMS). The main negative and positive low‐mass fragments are identified in the fingerprint part of the spectra (m/z < 400) and are principally assigned to fragmentation of the Bis‐MPA repeating units. In addition, it is shown that the fragmentation pattern is highly affected by the functional end‐groups. This is illustrated for a phthalic acid end‐capped hyperbranched polymer and for an acetonide‐terminated dendrimer analog. Also, typical fragments assigned to the ethoxylated pentaerythritol core molecule are detected. These ions show decreasing intensities with increasing molecular weight. This intensity dependency on the generation is used to calibrate the molecular weight of hyperbranched polyesters on the surface. To obtain quantitative information, a principal component analysis (PCA) multivariate statistical method is applied to the ToF‐SIMS data. The influence of different normalization procedures prior to PCA calculation is tested, e.g. normalization to the total intensity, to the intensities of ions assigned to the Bis‐MPA repeating unit or to intensities of fragments due to the core molecule. It is shown that only one principal component (PC1) is needed to describe most of the variance between the samples. In addition, PC1 takes into account the generation effect. However, different relationships between the PC1 scores and the hyperbranched mass average molecular weights are observed depending on the normalization procedure used. Normalization of data set ion intensities by ion intensities from the core molecule allows linearization of the SIMS intensities versus the molecular weight and allows the hyperbranched polymers to be discriminated up to the highest generations. In addition, PCA applied to ToF‐SIMS data provides an extended interpretation of the spectra leading to further identification of the correlated mass peaks, such as those of the Bis‐MPA repeating unit (terminal, dendritic and linear) and those of the core molecule. Finally, the work presented demonstrates the extreme potential of the static ToF‐SIMS and PCA techniques in the analysis of dendritic molecules on solid surfaces. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

7.
Amber is a polymerized plant resin having remarkable preservation potential in the geological record. Numerous analytical techniques have been applied to the study of amber organic chemistry in order to extract paleobotanical information. However, only exploratory work has been conducted using time‐of‐flight secondary ion mass spectrometry (ToF‐SIMS), despite its immense potential due to the high mass resolution and range that can be analyzed concurrently. Detailed assessments of ion fragmentation patterns are prerequisite, given that amber is comprised of a challenging range of terpenoids, carboxylic acids, alcohols, and associated esters. In recent work, we demonstrated the applicability and efficiency of ToF‐SIMS as a tool to investigate amber chemical composition. However, only two diterpene resin acid standards were considered in this preliminary study, namely abietic acid and communic acid. We now extend this work by documenting the ToF‐SIMS spectra of ten additional diterpene resin acids and ask whether ToF‐SIMS analysis can distinguish subtle differences within a larger set of diterpenoids. Both positive and negative ToF‐SIMS spectra were produced, although negative polarity appears particularly promising for differentiating diterpene resin acids. Principal component analysis (PCA) was used to distill the data and verified that purified diterpenes have distinct ToF‐SIMS spectra that can be applied to amber chemotaxonomy as well as to the analysis of modern resins of known botanical origin. While this work is pertinent to the study of the composition and histories of ambers, the mass spectra of the 12 diterpene standards could prove valuable to any system where diterpenoid chemistry plays a role. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

8.
In this paper, an improved approach to interpret results of principal component analysis (PCA) of time‐of‐flight secondary ion mass spectrometry (ToF‐SIMS) spectra is presented. Signals are typically observed in different intensity ranges in a single ToF‐SIMS spectrum due to different sensitivity factors and surface concentrations. This can complicate the PCA interpretation, because loadings are reported to be strongly affected by these intensity changes. In contrast, it is shown here that correlation loadings are unaffected by these differences. In particular, correlation loadings were successfully used to identify signals with relatively low intensity but high significance. These signals may be overlooked when only loadings are used. This is particularly true in failure analysis, where ToF‐SIMS is used to screen for initially unknown signals that may be relevant for the characteristics/failure of a product. As a model study, the concept was applied to investigate ageing of Li‐ion batteries by ToF‐SIMS. In this data set, the significance of impurities that affect the quality of Li‐ion batteries was identified only by correlation loadings, whereas the loadings were found to overestimate the influence of other matrix signals. In addition, correlation loadings aid in the chemical identification and helped to successfully assign unknown peaks.  相似文献   

9.
Time of flight secondary ion mass spectrometry (ToF‐SIMS) has been used to determine the extent of surface modification of highly ordered pyrolytic graphite (HOPG) samples that were exposed to radio‐frequency methane and hydrogen plasmas. The ToF‐SIMS measurements were examined with the multivariate method of principal component analysis (PCA), to maximise the amount of spectral information retained in the analysis. This revealed that the plasma (methane or hydrogen plasma) modified HOPG exhibited greater hydrogen content than the pristine HOPG. The hydrogen content trends observed from the ToF‐SIMS studies were also observed in elastic recoil detection analysis measurements. The application of the ToF‐SIMS PCA method also showed that small hydrocarbon fragments were sputtered from the hydrogen‐plasma‐treated sample, characteristic of the formation of a plasma‐damaged surface, whereas the methane‐plasma‐treated surface sputtered larger hydrocarbon fragments, which implies the growth of a polymer‐like coating. Scanning tunnelling microscopy measurements of the modified surfaces showed surface features that are attributable to either etching or film growth after exposure to the hydrogen or methane plasma. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

10.
Immiscible polymer systems are known to form various kinds of phase‐separated structures capable of producing self‐assembled patterns at the surface. In this study, different surface characterization methods were utilized to study the surface morphology and composition produced after annealing thin polymer films. Two different SIMS techniques—static time‐of‐flight secondary ion mass spectrometry (ToF‐SIMS) and dynamic nano‐SIMS—were used, complemented by x‐ray photoelectron spectrometry (XPS) and atomic force microscopy (AFM). Thin films (spin‐coated onto silicon wafers) of polystyrene (PS)–poly(methyl methacrylate) (PMMA) symmetric blends and diblock copolymers of similar molecular weight were investigated. Surface enrichment by PS was found on all as‐cast samples. The samples were annealed at 160 °C for different time periods, after which the blend and the copolymer films exhibited opposite behaviour as seen by ToF‐SIMS and XPS. The annealed blend surface presented an increase in the PMMA concentration whereas that of copolymers showed a decrease in PMMA concentration compared with the as‐cast sample. For blends, the nano‐SIMS as well as AFM images revealed the formation of phase‐separated domains at the surface. The composition information obtained from ToF‐SIMS and XPS, as well as the surface mapping by nano‐SIMS and AFM, allowed us to conclude that PS formed phase separated droplet‐like domains on a thin PMMA matrix on annealing. The three‐dimensional nano‐SIMS images showed that the PS droplets were supported inside a rim of PMMA and that these droplets continued from the surface like columnar rods into the film until the substrate interface. In the case of annealed copolymer samples, the AFM images revealed topographical features resembling droplet‐like domains on the surface but there was no phase difference between the domains and the matrix. In the case of copolymers, owing to the covalent bonding between the blocks, complete phase separation was not possible. The three‐dimensional nano‐SIMS images showed domain structures in the form of striations inside the film, which were not continuous until the substrate interface. Information from the different techniques was required to gain an accurate view of the surface composition and topographical changes that have occurred under the annealing conditions. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

11.
Layer‐by‐layer assemblies consisting of alternating layers of nitrilotris(methylene)triphosphonic acid (NTMP), a polyfunctional corrosion inhibitor, and zirconium(IV) were prepared on alumina. In particular, a nine‐layer (NTMP/Zr(IV))4NTMP stack could be constructed at room temperature, which showed a steady increase in film thickness throughout its growth by spectroscopic ellipsometry up to a final thickness of 1.79 ± 0.04 nm. At higher temperature (70 °C), even a two‐layer NTMP/Zr(IV) assembly could not be prepared because of etching of the alumina substrate by the heated Zr(IV) solution. XPS characterization of the layer‐by‐layer assembly showed a saw tooth pattern in the nitrogen, phosphorus, and zirconium signals, where the modest increases and decreases in these signals corresponded to the expected deposition and perhaps removal of NTMP and Zr(IV). Time‐of‐flight secondary ion mass spectrometry (ToF‐SIMS) confirmed the attachment of the NTMP molecule to the surface through PO?, PO2?, PO3?, and CN? signals. Increasing attenuation of the Al signal from the substrate after deposition of each layer was observed by both XPS and ToF‐SIMS. Essentially complete etching of the alumina by the heated Zr(IV) solution was confirmed by spectroscopic ellipsometry, XPS, and ToF‐SIMS. Atomic force microscopy revealed that all the films were smooth with Rq roughness values less than 0.5 nm. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

12.
Time‐of‐flight secondary ion mass spectrometry (ToF‐SIMS) has been used to perform a chemical analysis of long‐chain thiol (CH3(CH2)11SH)‐treated gold, silver, copper and platinum surfaces. All the mass peaks from positive and negative ion spectra within the range m/z = 0–2000 u are studied. ToF‐SIMS data revealed that on gold, silver and copper substrates 1‐dodecanethiol form dense standing‐up phases, but on platinum being a catalytically active substrate, we were able to identify also surface‐aligned parallel lying molecules in addition to a standing thiolate layer. Our study shows that when ToF‐SIMS spectra are analyzed, not only the existence of oligomers but also metal + hydrocarbon fragments give information about the order of SAM. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

13.
The efficient trapping of photogenerated thioaldehydes with functional shelf‐stable nitrile oxides in a 1,3‐dipolar cycloaddition is a novel and versatile photochemical strategy for polymer end‐group functionalization and surface modification under mild and equimolar conditions. The modular ligation in solution was followed in detail by electrospray ionization mass spectrometry (ESI‐MS). X‐ray photoelectron spectroscopy (XPS) was employed to analyze the functionalized surfaces, whereas time‐of‐flight secondary‐ion mass spectrometry (ToF‐SIMS) confirmed the spatial control of the surface functionalization using a micropatterned shadow mask. Polymer brushes were grown from the surface in a spatially confined regime by surface‐initiated atom transfer radical polymerization (SI‐ATRP) as confirmed by TOF‐SIMS, XPS as well as ellipsometry.  相似文献   

14.
ToF‐SIMS spectra are formed by bombarding a surface with a pulse of primary ions and detecting the resultant ionized surface species using a time‐of‐flight mass spectrometer. Typically, the detector is a time‐to‐digital converter. Once an ion is detected using such detectors, the detector becomes insensitive to the arrival of additional ions for a period termed as the (detector) dead‐time. Under commonly used ToF‐SIMS data acquisition conditions, the time interval over which ions arising from a single chemical species reach the detector is on the order of the detector dead‐time. Thus, only the first ion reaching the detector at any given mass is counted. The event registered by the data acquisition system, then, is the arrival of one or more ions at the detector. This behavior causes ToF‐SIMS data to violate, in the general case, the assumption of linear additivity that underlies many multivariate statistical analysis techniques. In this article, we show that high‐mass‐resolution ToF‐SIMS spectral‐image data follow a generalized linear model, and we propose a data transformation and scaling procedure that enables such data sets to be successfully analyzed using standard methods of multivariate image analysis. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

15.
Defects were created on the surface of highly oriented pyrolytic graphite (HOPG) by sputtering with an Ar+ ion beam, then characterized using X‐ray photoelectron spectroscopy (XPS) and time‐of‐flight secondary ion mass spectrometry (ToF‐SIMS) at 500°C. In the XPS C1s spectrum of the sputtered HOPG, a sp3 carbon peak appeared at 285.3 eV, representing surface defects. In addition, 2 sets of peaks, the Cx and CxH ion series (where x = 1, 2, 3...), were identified in the ToF‐SIMS negative ion spectrum. In the positive ion spectrum, a series of CxH2+• ions indicating defects was observed. Annealing of the sputtered samples under Ar was conducted at different temperatures. The XPS and ToF‐SIMS spectra of the sputtered HOPG after 800°C annealing were observed to be similar to the spectra of the fresh HOPG. The sp3 carbon peak had disappeared from the C1s spectrum, and the normalized intensities of the CxH and CxH2+• ions had decreased. These results indicate that defects created by sputtering on the surface of HOPG can be repaired by high‐temperature annealing.  相似文献   

16.
During the production of biofuels and/or bioproducts, wood and other lignocellulosic materials are frequently exposed to buffers during enzyme treatments. Buffer pH varies according to the activity profiles of the enzyme(s) used. Time‐of‐flight secondary ion mass spectrometry (ToF‐SIMS) is an increasingly valuable analytical tool for the surface analysis of lignocellulosic solids, allowing for characterization of the lignin and polysaccharides at the surface, along with other components such as protein and inorganic salts. Despite the use of ToF‐SIMS to characterize dilute acid and alkali pretreatments of wood, the exposure of wood to buffers of intermediate pH range has not been studied as it relates to ToF‐SIMS analysis. This leads to the question: “How does soaking wood in various pH buffers impact ToF‐SIMS spectra?” Accordingly, a softwood (spruce) and hardwood (birch) were soaked in universal buffers ranging from pH 5 to 10, and then positive ion ToF‐SIMS spectra were acquired from the washed wood. Deacetylation was evident for both wood species above pH 8. Additionally, at higher pH, birch ToF‐SIMS spectra revealed a relative loss in polysaccharide peaks attributed to hemicellulose and an increase in lignin peaks. This study provides a basis for understanding the pH‐dependent alteration of wood solids in aqueous solution, which is important for understanding the controls in enzyme treatments.  相似文献   

17.
Time‐of‐flight secondary ion mass spectrometry (ToF‐SIMS) is a powerful tool for determining surface information of complex systems such as polymers and biological materials. However, the interpretation of ToF‐SIMS raw data is often difficult. Multivariate analysis has become effective methods for the interpretation of ToF‐SIMS data. Some of multivariate analysis methods such as principal component analysis and multivariate curve resolution are useful for simplifying ToF‐SIMS data consisting of many components to that explained by a smaller number of components. In this study, the ToF‐SIMS data of four layers of three polymers was analyzed using these analysis methods. The information acquired by using each method was compared in terms of the spatial distribution of the polymers and identification. Moreover, in order to investigate the influence of surface contamination, the ToF‐SIMS data before and after Ar cluster ion beam sputtering was compared. As a result, materials in the sample of multiple components, including unknown contaminants, were distinguished. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

18.
Time‐of‐flight secondary ion mass spectrometry (ToF‐SIMS) has demonstrated applicability to the analysis of lignocellulosic samples including pulp, paper, plants, and wood. One such application is to use ToF‐SIMS as a tool for detecting the activity of enzymes applied to degrade or modify plant biomass. The use of buffers for pH control of these enzymatic reactions can pose problems due to the nature of the ToF‐SIMS measurement. Specifically, inorganic species (e.g. salts) from buffer components could introduce several concerns for quantitative or semi‐quantitative ToF‐SIMS analysis. First, salts can produce additional peaks in the mass spectra, which may overlap with lignocellulose peaks of interest (mass interference). Second, salts can alter the chemical environment, or ‘matrix’, altering the ionization probability of lignocellulose‐related secondary ions during the sputtering mechanism of the ToF‐SIMS measurement (matrix effects). Third, salts may physically coat the lignocellulose surface, decreasing the signal from the lignocellulose, causing poor signal‐to‐noise in the analysis. The current work presents a simple approach for identifying interferences due to buffers, using both principal component analysis (PCA) and previously established lignocellulose‐relevant peak ratios. Furthermore, a simple acetic acid rinsing protocol is compared to distilled water rinsing and is evaluated and for its effectiveness in removing buffer‐related salts. The data shows that briefly rinsing lignocellulose samples in dilute acetic acid can be effective in restoring the validity of lignocellulose composition interpretations using ToF‐SIMS. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

19.
Quantitative analyses in secondary ion mass spectrometry (SIMS) become possible only if ionization processes are controlled. The Storing Matter technique has been developed to circumvent this so‐called matrix effect, primarily for inorganic samples, but has also been extended to organic samples. For the latter, it has been applied to polystyrene in order to investigate the extent of damage in the polymer, its fragmentation during the sputter deposition process and the effect of the deposition process on the spectra taken by Time‐of‐Flight SIMS (ToF‐SIMS). In this work, a multi‐technique approach, which employs the Storing Matter technique for deposition and ToF‐SIMS and X‐ray photoelectron spectroscopy for characterization, is used to enhance the control of the deposition process, including the thickness of the deposit, the alteration of the source film and the influence of polymer composition on the Storing Matter process. Poly (methyl methacrylate) (PMMA) is used for this work. More detailed information about the sticking of polymer fragments on the metal collector is obtained by density functional theory calculations. This work allows for the conclusion that a part of the fragments deposited on the collector surface diffuses on the latter, reacts and recombines to form larger fragments. The behaviour observed for PMMA is similar to polystyrene, showing that oxygen has no major influence on the processes occurring during the sputter deposition process. Additionally, we have developed a new methodology using 2D ToF‐SIMS images of the deposit to monitor the deposit thickness and to identify surface contaminations. The latter are not only located at the position of the deposit but all over the collector surface. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

20.
A novel physical entrapment process has been explored as an approach to surface incorporation of proteins within pre‐formed alginate fibres under mild conditions. Entrapment of the protein of choice was achieved by exposing the alginate fibres to a Na+‐rich NaCl/CaCl2 mixture solution, which caused the formation of a moderate dissociation layer into which the protein could diffuse. Subsequent addition of a large excess of multi‐valent cations led to the collapse of the surface and entrapment of the protein within the surface. Bovine serum albumin (BSA) was used as a model protein to investigate the effect of process parameters on the entrapment efficiency. Scanning electron microscopy revealed that there was an increase in the surface roughness and a slight increase in the average diameter of the fibres after protein entrapment. The presence of the protein at the surface of alginates after the entrapment process was confirmed by means of confocal laser‐scanning microscopy, X‐ray photoelectron spectroscopy (XPS) and time‐of‐flight secondary ion mass spectrometry (ToF‐SIMS). The ion exchanges at the surface were evident, as detected by XPS and ToF‐SIMS. It was found that under fixed pre‐swelling conditions, the entrapment efficiency increased with increasing treatment time and, particularly, with protein concentration in the exposure solution. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号