首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
The effects of different surface modifications on the adhesion of copper to a liquid‐crystalline polymer (LCP) were investigated with X‐ray photoelectron spectroscopy, scanning electron microscopy, atomic force microscopy, contact‐angle measurements, and pull tests. High pull‐strength values were achieved when copper was sputter‐deposited onto plasma and reactive‐ion‐etching (RIE)‐pretreated LCP surfaces. The values were comparable to the reference pull strengths obtained with laminated copper on the LCP. The adhesion was relatively insensitive to the employed feed gas in the pretreatments. The surface characterizations revealed that for RIE and plasma treatments, the enhanced adhesion was attributable to the synergistic effects of the increased surface roughness and polar component of the surface free energy of the polymer. However, if the electroless copper deposition was performed on RIE‐ or plasma‐treated surfaces, very poor adhesion was measured. Good adhesion between the LCP substrate and electrolessly deposited copper was achieved only in the case of wet‐chemical surface roughening as a result of the creation of a sufficient number of mechanical interlocking sites, together with a significant loss of oxygen functionalities, on the surface. © 2003 Wiley Periodicals, Inc. J Polym Sci Part B: Polym Phys 41: 623–636, 2003  相似文献   

2.
Material surface properties of polymers, plastics, ceramics and textiles can be modified by atmospheric or low‐pressure glow discharge plasma. The aim of the present work is to study the surface modification of biaxially oriented polypropylene (BOPP) film in order to improve its hydrophilic and wetting properties. In this article we used low‐pressure, low‐temperature oxygen plasma for the surface treatment of BOPP. Scanning electron microscopy indicates that plasma treatment causes mainly physical changes by creating microcraters and roughness on the surface and increasing surface friction. Attenuated total reflectance infrared spectra show oxygen‐containing groups such as ? OH at 3513 cm?1 and C?O at 1695 cm?1. Microscopic investigations of water droplets on BOPP (treated, untreated) show that the interfacial adhesion of treated surfaces is increased. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

3.
Micropatterns of cells on a poly(vinyl chloride) (PVC) film surface were created by using ion irradiation. A PVC film was irradiated with H+ ions through a pattern mask in order to create patterns of the hydrophilic/hydrophobic regions on the PVC surface. The effect of ion irradiation on the surface properties of the PVC film was characterized by using Fourier transform‐infrared spectroscopy (FT‐IR), water contact angle measurement, and X‐ray photoelectron spectroscopy (XPS). The results revealed that the chemical environment of the PVC film surface was effectively changed by ion irradiation due to dehydrochlorination and oxidation. The in vitro cell culture on the patterned PVC film surface showed selective adhesion and proliferation of the cells on the ion‐irradiated regions. Well‐defined 50 µm patterns of the cells were obtained on the PVC film surface irradiated to 1 × 1015 ions/cm2. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

4.
The surface of poly(p-phenylene terephthalamide) (PPTA) films was modified by oxygen plasma, and the modified film surface was analyzed by an advancing contact meter and X-ray photoelectron spectroscopy (XPS). The advancing contact measurement showed that the oxygen plasma treatment made the surface of the PPTA film hydrophilic. The XPS analyses also showed the increase in the O/C and N/C atom ratio, especially the O/C atom ratio, at the PPTA film surface by the oxygen plasma treatment. A main oxygen functionality formed by the oxygen plasma treatment is a carboxylic acid group, and a main nitrogen functionality formed is a protonated amino group. The formation of the oxygen and nitrogen functionalities formed by the oxygen plasma treatment is not restricted to the surface of the PPTA film, but penetrates at least 35 Å deep from the film surface. The formation of these carboxylic acid and protonated amino groups is a result of the bond scission of the amide linkages in the PPTA film. Interactions of photons in the oxygen plasma rather than interactions of electrons and activated oxygen atoms contribute greatly to the bond scission. © 1995 John Wiley & Sons, Inc.  相似文献   

5.
We present an XPS method to determine the termination of the ZnO(0001) surface. By measuring O 1s and Zn 2p3/2 core‐level x‐ray photoelectron spectra at photoemission angles of 0° and 70° and comparing the intensity ratio (IO1s/IZn2p3)θ=0/(IO1s/IZn2p3)θ=70, the Zn and O termination can be distinguished. Calculations show that these two terminations have intensity ratios differing by ~17%. This difference is not affected by a contamination layer provided that the contamination layer thickness is the same for these two differently terminated surfaces. Although this determination method prefers a clean ZnO(0001) surface (in situ measurement), it seems also feasible for surfaces with known contamination layer thickness (ex situ measurement). We have measured ex situ ZnO(0001)‐Zn, ZnO(000&1macr;)‐O single crystals and an epitaxial ZnO film deposited on Al2O3(0001). The measured intensity ratios of the first two samples agree with the calculated values for a 0.2 and 0.26 nm contamination layer, respectively. The intensity ratio and the O 1s contamination component intensity of the epitaxial ZnO film are close to those of the ZnO(0001)‐Zn single crystal thus pointing at Zn termination of the film. Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

6.
Hydroxyapatite was surface-modified by adsorption of nonionic polymers carrying phosphate groups as anchoring groups. A combination of alcohol ethoxylate and alkyl phosphate was also used. The possibility of interfering with early microbial colonization on apatite, mimicking the tooth surface, was investigated using radiolabelledStreptococcus mutans as model bacteria. The polymers, a nonionic cellulose ether and an EO/PO block copolymer based on polyglycerol as starting alcohol, were effective in buffer but gave only limited reduction of bacterial adhesion when the apatite had been pretreated with saliva. A 11 molar mixture of alcohol ethoxylate and alkyl phosphate was effective both with and without saliva, however. Studies with14C-labeled compounds, as well as microelectrophoresis experiments, indicate that an unsymmetrical double layer is formed on the apatite surface with predominantly alkyl phosphate in the inner layer and with alcohol ethoxylate pointing towards the water phase.  相似文献   

7.
Poly(dimethylsiloxane) (PDMS) has a long history of exploitation in a variety of biological and medical applications. Particularly in the past decade, PDMS has attracted interest as a material for the fabrication of microfluidic biochip. The control of cell adhesion on a PDMS surface is important in many microfluidic applications such as cell culture or cell‐based chemicals/drug testing. Unlike many complicated approaches, this study reports simple methods of PDMS surface modification to effectively inhibit or conversely enhance cell adhesion on a PDMS surface using Pluronic surfactant solution and poly‐L ‐lysine, respectively. This research basically succeeded our prior work to further confirm the long‐term capability of 3% Pluronic F68 surfactant to suppress cell adhesion on a PDMS surface over a 6‐day cell culture. Microscopic observation showed that the treated PDMS surface created an unfavorable interface, where chondrocytes seemed to clump together on day 2 and 6 after chondrocyte seeding, and there was no sign of chondrocyte spreading. On the opposite side, results demonstrated that the poly‐L ‐lysine‐treated surface significantly increased fibroblast adhesion by 32% in contrast to the untreated PDMS, which is comparable to the commercial cell‐culture‐grade microplate. However, fibronectin treatment did not have such an effect. All these fundamental information is found useful for any PDMS‐related application. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

8.
A novel and facile activation process for electroless nickel deposition was developed. The semi‐interpenetrating polymer network hydrogel biofilm was used to functionalize the inert poly(vinyl chloride) (PVC) surface, and then Cu nanoparticles, which can initial the subsequent electroless nickel deposition successfully seeded on the functionalized‐PVC surface. The samples were characterized by scanning electron microscopy, X‐ray photoelectron spectroscopy, X‐ray diffraction, and transmission electron microscopy. The results show that the hydrogel film provided the PVC surface with amino groups and Cu nanoparticles of 20–50 nm in size could be functioned as the catalytic nuclei for the subsequent electroless metal deposition on PVC plastic. It can be concluded that the novel Cu activation was effective for the nickel deposition on PVC surface, because of more chemisorption sites for Cu nanoparticles generated on PVC surface. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

9.
Poly(tetrafluoroethylene) (PTFE) films were treated with a low-temperature cascade arc torch (LTCAT) and radio-frequency (RF) plasmas of argon and hydrogen. The plasma-treatment effect on the PTFE surface was studied with contact-angle measurement and scanning electron spectroscopy (SEM). LTCAT argon plasma, which is recognized as a beam of excited argon neutrals, was very efficient at improving the surface hydrophilicity of PTFE. For both the LTCAT and RF operation, argon plasma was more effective at modifying the surface wettability of PTFE films than hydrogen plasma was. Furthermore, the sample positions (inside or beyond the glow region) had a strong impact on the efficiency of the plasma treatment. SEM surface images indicated that no significant morphology change was induced on the PTFE films exposed to a LTCAT and RF argon plasmas. © 1999 John Wiley & Sons, Inc. J Polym Sci A: Polym Chem 37: 4432–4441, 1999  相似文献   

10.
聚氯乙烯表面共价键合肝素及抗凝血性的研究   总被引:8,自引:0,他引:8  
采用Ar等离子体引发聚乙二醇(PEG)在聚氯乙烯(PVC)表面固定化,进一步对固定PEG后的PVC进行肝素化处理,以改善PVC材料的抗凝血性能。探讨了PEG浓度对Ar等离子体固定化反应效果的影响。通过X射线光电子能谱(XPS)、衰减全反射红外光谱(ATR-FTIR)、扫描电镜(SEM)和接触角测定研究了固定PEG前后PVC的表面性能和表面形貌的变化。XPS分析证实肝素已成功地共价键合于PVC表面。采用体外凝血时间测定和血小板粘附实验对材料的抗凝血性能进行评价,结果表明,被修饰PVC材料的抗凝血性能显著提高。  相似文献   

11.
We present a new method for creating surface chemical patterns where three chemistries can be periodically arranged at alternate positions on a single substrate without the use of top‐down approaches. High‐resolution chemical imaging by time‐of‐flight secondary ion mass spectrometry (ToF‐SIMS), with nanometer spatial resolution, is used to prove the success of the patterning and subsequent chemical modification steps. We use a combination of colloidal self‐assembly, plasma etching, self‐assembled monolayers (SAMs) and physical vapour deposition (PVD). The method utilizes a double colloid assembly process in which a first layer of close‐packed colloids is created, followed by plasma etching, coating with gold and deposition of a first SAM layer. A second particle layer is deposited on top of the first layer masking the interstitial spaces containing the first SAM. A second gold layer is deposited followed by a second SAM. After particle removal the surface consists of the pattern containing two different SAMs and a SiO2 layer that can be readily functionalized with silanes. The possibility in the replacement of the two different thiols is investigated by X‐ray photoelectron spectroscopy (XPS) and it was found that no replacement is taking place. ToF‐SIMS imaging is used to show the periodicity of the chemical patterns by tracking unique fragment ions from the different surface regions. The patterning method is adaptable to create smaller or larger chemical patterns by appropriate choice of particle sizes. The patterns are useful for immobilizing biomolecules for cell studies or as multiplexed biosensors.  相似文献   

12.
Angle‐resolved X‐ray photoelectron spectroscopy (ARXPS) data taken on a polystyrene film exposed to a nitrogen plasma are interpreted by the fitting of regularized depth profiles. Three ways of measuring the goodness of fit are compared—the χ2 statistic with variances drawn from the raw spectra, the χ2 statistic with variances drawn from the concentration figures obtained from the data analysis, and a simple sum of the squared differences (ssd) that does not require variances to be calculated. It is shown that for these data, the depth profiles obtained using an objective method for the choice of the regularization parameter are essentially identical irrespective of whether or how the variances are introduced into the calculation. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

13.
The X‐ray‐induced sample damage during mono XPS analysis of an oxygen‐plasma‐oxidized and subsequently wet‐chemically reduced poly(propylene) film was investigated as a showcase for plasma‐modified or plasma‐deposited samples. By doing this, the degradation index approach as introduced by Beamson and Briggs in the Scienta ESCA300 high‐resolution XPS database of organic polymers has been adopted. As to be expected, the sample degrades by loosing oxygen as revealed by observation of decreasing O/C and C OR/Csum ratios. However, the X‐ray degradation indices are definitely higher than those of conventional reference polymers. Moreover, the C OR/Csum degradation index is significantly higher in comparison with one obtained for the O/C ratio. In that context, there is no difference between the plasma sample and a conventional poly(vinyl alcohol) polymer. It is concluded that for reliable quantitative surface chemical analysis, the quality of spectra in terms of acquisition times must be optimized aimed to a minimization of X‐ray degradation. Finally, it is proposed to describe the photon flux of an X‐ray gun in an XPS experiment, which defines the degradation rate at the end, by using the sample current simply measured with a carefully grounded sputter‐cleaned reference silver sample. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

14.
Difference X‐ray photoelectron spectroscopy (D‐XPS) revealed the surface oxidation process of a diamond‐like carbon (DLC) film. Evaluation of surface functional groups on DLC solely by the C 1s spectrum is difficult because the spectrum is broad and has a secondary asymmetric lineshape. D‐XPS clarified the subtle but critical changes at the DLC surface caused by wet oxidation. The hydroxyl (C―OH) group was dominant at the oxidized surface. Further oxidized carbonyl (C?O) and carboxyl (including carboxylate) (COO) groups were also obtained; however, the oxidation of C?O to COO was suppressed to some extent because the reaction required C―C bond cleavage. Wet oxidation cleaved the aliphatic hydrogenated and non‐hydrogenated sp2 carbon bonds (C―H sp2 and C―C sp2) to create a pair of C―OH and hydrogenated sp3 carbon (C―H sp3) bonds. The reaction yield for C―H sp2 was superior at the surface, suggesting that the DLC film was hydrogen rich at the surface. Oxidation of aromatic sp2 rings or polycyclic aromatic hydrocarbons such as nanographite to phenols did not occur because of their resonance stabilization with electron delocalization. Non‐hydrogenated sp3 carbon (C―C sp3) bonds were not affected by oxidation, suggesting that these bonds are chemically inert. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

15.
16.
17.
The covalent attachment of [60]fullerene (C60) to two poly(vinyl chloride) (PVC) samples with different isotactic content is achieved by direct reaction in o‐dichlorobenzene (o‐DCB) solution in the presence of AIBN. The extent of fullerenation is controlled by varying the C60 feed ratio. The pendant C60‐chemically modified PVC polymers are soluble in tetrahydrofuran (THF) and have been characterized by UV–vis, NMR, FTIR, DSC, TGA, cyclic voltammetry, and SEM. The quantitative microstructural analysis after covalent attachment of the bulky C60 moiety to the PVC has been followed by 13C NMR spectroscopy. From the results it can be concluded that the modification of PVC by graft reaction through free radical reaction proceeds by a stereoselective mechanism. This conclusion has been confirmed on the basis of the increase of the glass‐transition temperature (Tg) and the thermal stability of the C60‐chemical modified PVC samples. The fullerenated PVCs obtained show good electron acceptor properties, as evidenced by electrochemical investigations. © 2007 Wiley Periodicals, Inc. J Polym Sci Part A: Polym Chem 45: 5408–5419, 2007  相似文献   

18.

Three different chemical stabilizers were introduced into neat PVC and a wood/PVC composite (containing 50 phr wood flour) to improve their thermal and structural stabilities. The changes in CIE yellowness index, polyene index, %wt loss, and decomposition temperature (Td) were monitored. The effects of type and content of thermal stabilizers, thermal ageing time, and the presence of wood flour were our main interests. The experimental results suggested that the additions of Zn and Pb stearates into PVC and wood/PVC composite could improve the thermal stability of the PVC. At the test temperature of 177°C, the additions of Zn and Pb stearates could improve the thermal stabilities of PVC by retarding the upzipped reaction and by reducing the conjugated double bonds in PVC, Pb stearate being the most suitable for thermally stabilizing the PVC. Around the Td range (~264°C), the addition of Zn stearate reduced the Td value of PVC whereas that of Pb stearate had no effect on the change in Td value. Zeolite loading could shift the Td value of the PVC from 264 to 280°C. The addition of wood particles increased the polyene content and decreased the decomposition temperature of the PVC. The effect of wood flour on the thermal and structural changes of PVC overruled that of thermal stabilizer loading.  相似文献   

19.
Films of polyethylene terephthalate were deposited on quartz crystals and exposed to oxygen atoms to study their etching characteristics and quantify the etching rate. Oxygen (O) atoms were created by passing molecular oxygen through plasma created in a microwave discharge. The discharge power was fixed at 250 W, while the pressure of oxygen was 50 Pa. Before exposure to oxygen atoms, a thin polymer film of polyethylene terephthalate (PET) was deposited uniformly over a crystal with a diameter of 12 mm. The crystal was mounted on a quartz crystal microbalance to accurately determine the thickness of the polymer film. The polymer film was exposed to O atoms in the flowing afterglow. The density of O atoms was measured with a cobalt catalytic probe mounted next to the sample and was determined to be 1.2 × 1021 m–3. Samples were treated with O atoms for different periods of up to 120 min. The thickness of the film decreased linearly with treatment time. After 90 min of treatment, a 65‐nm‐thick polymer film was completely removed. Therefore, the etching rate was 0.5 nm/min, so the interaction probability between an O atom and an atom in the sample was extremely low, just 1.4 × 10–6. Samples treated for different periods were investigated by atomic force microscopy and X‐ray photoelectron spectroscopy to examine the etching characteristics of O atoms in the flowing afterglow. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

20.
Poly(glycidyl methacrylate), PGMA, chains in linear and arborescent structures were incorporated onto surfaces of poly(tetrafluoroethylene), PTFE, films by hydrogen plasma and ozone treatment and atom transfer radical polymerization. The epoxide groups of the PGMA chains were further reacted with acetic acid (AAc), oxalic acid (XAc), allyl amine (AA), and ethylenediamine (EDN) to introduce hydroxyl and amine groups to the surfaces of the PTFE films. Surface characterizations performed by Fourier Transform infrared attenuated total reflectance (FTIR-ATR) spectroscopy and X-ray photoelectron spectroscopy (XPS) confirmed the surface modification and the chemical structure. The PGMA chains in arborescent structures show a high effectiveness for the enhancement of the adhesion of PTFE films. The adhesion of PTFE films was also significantly enhanced by ring-opening reactions of the PGMA epoxide groups with acetic acid and amine compounds. A high value of 9.5 N cm(-1) in the optimum 180 degrees peel strength test was observed with PTFE/copper assemblies.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号