首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 125 毫秒
1.
The paper reports on experimental studies of electron beams in the ISTTOK tokamak, those were performed by means of an improved four‐channel detector. The Cherenkov‐type detector measuring head was equipped with four radiators made of two types of alumina‐nitrate (AlN) poly‐crystals: machinable and translucent ones, both of 10 mm in diameter and 2.5 mm in thickness. The movable support that enabled the whole detectors to be placed inside the tokamak vacuum chamber, at chosen positions along the ISTTOK minor radius. Since the electron energy distribution is one of the most important characteristics of tokamak plasmas, the main aim of the study was to perform estimations of an energy spectrum of the recorded electrons. For this purpose the radiators were coated with molybdenum (Mo) layers of different thickness. The technique based on the use of Cherenkov‐type detectors enabled the detection of fast electrons (of energy above 66 keV) and determination of their spatial and temporal characteristics in the ISTTOK experiment. Measurements of hard X‐rays (HXR), which were emitted during ISTTOK discharges, have also been performed. Particular attention was paid to the correlation measurements of HXR pulses with run‐away electron beams. (© 2013 WILEY‐VCH Verlag GmbH & Co. KGaA, Weinheim)  相似文献   

2.
Recently, CdZnTe (CZT) detectors have been widely proposed and developed for room‐temperature X‐ray spectroscopy even at high fluxes, and great efforts have been made on both the device and the crystal growth technologies. In this work, the performance of new travelling‐heater‐method (THM)‐grown CZT detectors, recently developed at IMEM‐CNR Parma, Italy, is presented. Thick planar detectors (3 mm thick) with gold electroless contacts were realised, with a planar cathode covering the detector surface (4.1 mm × 4.1 mm) and a central anode (2 mm × 2 mm) surrounded by a guard‐ring electrode. The detectors, characterized by low leakage currents at room temperature (4.7 nA cm?2 at 1000 V cm?1), allow good room‐temperature operation even at high bias voltages (>7000 V cm?1). At low rates (200 counts s?1), the detectors exhibit an energy resolution around 4% FWHM at 59.5 keV (241Am source) up to 2200 V, by using commercial front‐end electronics (A250F/NF charge‐sensitive preamplifier, Amptek, USA; nominal equivalent noise charge of 100 electrons RMS). At high rates (1 Mcounts s?1), the detectors, coupled to a custom‐designed digital pulse processing electronics developed at DiFC of University of Palermo (Italy), show low spectroscopic degradations: energy resolution values of 8% and 9.7% FWHM at 59.5 keV (241Am source) were measured, with throughputs of 0.4% and 60% at 1 Mcounts s?1, respectively. An energy resolution of 7.7% FWHM at 122.1 keV (57Co source) with a throughput of 50% was obtained at 550 kcounts s?1 (energy resolution of 3.2% at low rate). These activities are in the framework of an Italian research project on the development of energy‐resolved photon‐counting systems for high‐flux energy‐resolved X‐ray imaging.  相似文献   

3.
EIGER is a single‐photon‐counting hybrid pixel detector developed at the Paul Scherrer Institut, Switzerland. It is designed for applications at synchrotron light sources with photon energies above 5 keV. Features of EIGER include a small pixel size (75 µm × 75 µm), a high frame rate (up to 23 kHz), a small dead‐time between frames (down to 3 µs) and a dynamic range up to 32‐bit. In this article, the use of EIGER as a detector for electrons in low‐energy electron microscopy (LEEM) and photoemission electron microscopy (PEEM) is reported. It is demonstrated that, with only a minimal modification to the sensitive part of the detector, EIGER is able to detect electrons emitted or reflected by the sample and accelerated to 8–20 keV. The imaging capabilities are shown to be superior to the standard microchannel plate detector for these types of applications. This is due to the much higher signal‐to‐noise ratio, better homogeneity and improved dynamic range. In addition, the operation of the EIGER detector is not affected by radiation damage from electrons in the present energy range and guarantees more stable performance over time. To benchmark the detector capabilities, LEEM experiments are performed on selected surfaces and the magnetic and electronic properties of individual iron nanoparticles with sizes ranging from 8 to 22 nm are detected using the PEEM endstation at the Surface/Interface Microscopy (SIM) beamline of the Swiss Light Source.  相似文献   

4.
5.
Third‐generation synchrotron radiation sources pose difficult challenges for energy‐dispersive detectors for XAFS because of their count rate limitations. One solution to this problem is the bent crystal Laue analyzer (BCLA), which removes most of the undesired scatter and fluorescence before it reaches the detector, effectively eliminating detector saturation due to background. In this paper experimental measurements of BCLA performance in conjunction with a 13‐element germanium detector, and a quantitative analysis of the signal‐to‐noise improvement of BCLAs are presented. The performance of BCLAs are compared with filters and slits.  相似文献   

6.
Typically, X‐ray absorption near‐edge structure measurements aim to probe the linear attenuation coefficient. These measurements are often carried out using partial fluorescence yield techniques that rely on detectors having photon energy discrimination improving the sensitivity and the signal‐to‐background ratio of the measured spectra. However, measuring the partial fluorescence yield in the soft X‐ray regime with reasonable efficiency requires solid‐state detectors, which have limitations due to the inherent dead‐time while measuring. Alternatively, many of the available detectors that are not energy dispersive do not suffer from photon count rate limitations. A filter placed in front of one of these detectors will make the energy‐dependent efficiency non‐linear, thereby changing the responsivity of the detector. It is shown that using an array of filtered X‐ray detectors is a viable method for measuring soft X‐ray partial fluorescence yield spectra without dead‐time. The feasibility of this technique is further demonstrated using α‐Fe2O3 as an example and it is shown that this detector technology could vastly improve the photon collection efficiency at synchrotrons and that these detectors will allow experiments to be completed with a much lower photon flux reducing X‐ray‐induced damage.  相似文献   

7.
The design and performance characterization of a new light‐weight and compact X‐ray scintillation detector is presented. The detectors are intended for use on the new I11 powder diffraction beamline at the third‐generation Diamond synchrotron facility where X‐ray beams of high photon brightness are generated by insertion devices. The performance characteristics of these detection units were measured first using a radioactive source (efficiency of detection and background count rate) and then synchrotron X‐rays (peak stability, light yield linearity and response consistency). Here, the results obtained from these tests are reported, and the suitability of the design for the Diamond powder beamline is demonstrated by presenting diffraction data obtained from a silicon powder standard using a prototype multicrystal analyser stage.  相似文献   

8.
9.
Precise monitoring of the incoming photon flux is crucial for many experiments using synchrotron radiation. For photon energies above a few keV, thin semiconductor photodiodes can be operated in transmission for this purpose. Diamond is a particularly attractive material as a result of its low absorption. The responsivity of a state‐of‐the art diamond quadrant transmission detector has been determined, with relative uncertainties below 1% by direct calibration against an electrical substitution radiometer. From these data and the measured transmittance, the thickness of the involved layers as well as the mean electron–hole pair creation energy were determined, the latter with an unprecedented relative uncertainty of 1%. The linearity and X‐ray scattering properties of the device are also described.  相似文献   

10.
《X射线光谱测定》2006,35(3):178-183
Improving the specificity and productivity of XRF is of great relevance for the determination of trace elements in samples of diverse origin. The advantages of using digital signal processing in energy‐dispersive polarized x‐ray fluorescence analysis are demonstrated by comparing the instrumental sensitivities achieved with those obtained by using a conventional analogue signal processing‐based spectrometer. A compact geometry secondary target arrangement was designed to increase the effective solid angles and to reduce the distances between secondary target, sample and detector, thus achieving larger x‐ray fluxes for both the excitation and detection process, resulting in improved instrumental sensitivities. The performance of both spectrometers was evaluated for two different detectors: an Si(Li) detector and a thermoelectrically cooled passivated‐implanted planar silicon detector (X‐PIPS). The uncertainties achieved and accuracy are illustrated for the analysis of a group of sediment and organic‐origin certified reference materials using two different quantitative procedures. Copyright © 2006 John Wiley & Sons, Ltd.  相似文献   

11.
Cerium-doped lanthanum bromide (LaBr3:Ce) crystals offer a range of improved scintillation properties over traditional NaI:Tl crystals for in situ gamma spectrometry. At present, however, it remains unclear whether the internal radioactivity of LaBr3:Ce detectors compromises their suitability for low-level activity radioisotope measurements of natural sedimentary deposits, such as those required in luminescence and electron spin resonance (ESR) dating. In this study we investigate the suitability of a commercial LaBr3:Ce detector for measuring individual concentrations of 40K, 238U and 232Th using predefined ‘energy windows’ from gamma ray spectra. Performance tests have been undertaken using reference materials with well-constrained radioisotope concentrations (the Oxford calibration blocks) and compared with results obtained for a NaI:Tl detector of the same geometry. These tests reveal that the LaBr3:Ce detector has a non-negligible intrinsic activity that needs to be accurately quantified prior to measuring any gamma ray spectra in the field. Compared to the NaI:Tl detector, the energy resolution of the LaBr3:Ce detector is improved by a factor of two, or more, for the main indicator isotope photopeaks in the 40K, 238U and 232Th decay series. Signal-to-noise ratios for the LaBr3:Ce detector show a 25-35% improvement over those of the NaI:Tl detector. In addition, the LaBr3:Ce detector is characterised by suitable energy linearity over the full spectral range of interest for the 40K, 238U and 232Th decay series. Replicate gamma ray measurements made with the LaBr3:Ce and NaI:Tl detectors for 20 natural sedimentary samples from the Lower Tejo River basin, Portugal, and the Duero River basin, Spain, yield consistent radioisotope concentrations and gamma dose rate estimates. These results are encouraging and suggest that LaBr3:Ce detectors can provide suitable estimates of individual radioisotope concentrations in low-level activity (0.5-1.5 Gy/ka) environments, providing that their intrinsic activity is adequately measured and subtracted from field spectra. Our comparison also reveals that subtraction of the intrinsic activity from LaBr3:Ce spectra produces a significant reduction in the precision with which radionuclide concentrations can be determined using the ‘energy windows’ approach. This shortcoming necessitates longer counting times in natural sedimentary environments and overshadows the practical advantages that LaBr3:Ce detectors might otherwise offer for luminescence and ESR dating applications.  相似文献   

12.
The high brilliance of third‐generation synchrotron sources increases the demand for faster detectors to utilize the available flux. The Maia detector is an advanced imaging scheme for energy‐dispersive detection realising dwell times per image‐pixel as low as 50 µs and count rates higher than 10 × 106 s?1. In this article the integration of such a Maia detector in the Microprobe setup of beamline P06 at the storage ring PETRA III at the Deutsches Elektronen‐Synchrotron (DESY) in Hamburg, Germany, is described. The analytical performance of the complete system in terms of rate‐dependent energy resolution, scanning‐speed‐dependent spatial resolution and lower limits of detection is characterized. The potential of the Maia‐based setup is demonstrated by key applications from materials science and chemistry, as well as environmental science with geological applications and biological questions that have been investigated at the P06 beamline.  相似文献   

13.
碲锌镉材料(CdZnTe)是目前探测X射线和γ射线的最好材料之一。将241 Am和137 Cs辐射源作用于像素CdZnTe探测器,通过实验和仿真分别得到能量谱估计、能量分辨率和峰值效率。由实验和仿真结果得出:在662keV的高能量下,厚度较大的CdZnTe探测器可获得更高的能量分辨率和峰值效率,但在59.5keV低能处会出现拖尾升高和电荷损失的现象;厚度较薄的探测器在低能处的特性反而更好。  相似文献   

14.
In order to achieve a high resolution in the spectroscopy of low energy X-rays, detectors based on superconducting tunnel junctions as sensors are presently investigated. The knowledge of the processes affecting the signal generation in such sensors is essential for the interpretation of the detector response. Starting from a diffusion model including decay and tunneling of excess quasiparticles in the metal layers of a superconducting tunnel junction detector, the detector response is determined as a function of absorption position and of rate constants. Model predictions agree very well with experimental data. The advantages of a detector employing quasiparticle trapping are pointed out and the parameters determining the signal gain are deduced. The linearity of the detector signal is much more affected by pair recombination of the quasiparticles during their tunneling rather than during their diffusive propagation into the tunneling region.  相似文献   

15.
An end‐station for X‐ray Raman scattering spectroscopy at beamline ID20 of the European Synchrotron Radiation Facility is described. This end‐station is dedicated to the study of shallow core electronic excitations using non‐resonant inelastic X‐ray scattering. The spectrometer has 72 spherically bent analyzer crystals arranged in six modular groups of 12 analyzer crystals each for a combined maximum flexibility and large solid angle of detection. Each of the six analyzer modules houses one pixelated area detector allowing for X‐ray Raman scattering based imaging and efficient separation of the desired signal from the sample and spurious scattering from the often used complicated sample environments. This new end‐station provides an unprecedented instrument for X‐ray Raman scattering, which is a spectroscopic tool of great interest for the study of low‐energy X‐ray absorption spectra in materials under in situ conditions, such as in operando batteries and fuel cells, in situ catalytic reactions, and extreme pressure and temperature conditions.  相似文献   

16.
The first X‐ray photon correlation spectroscopy experiments using the fast single‐photon‐counting detector PILATUS (Paul Scherrer Institut, Switzerland) have been performed. The short readout time of this detector permits access to intensity autocorrelation functions describing dynamics in the millisecond range that are difficult to access with charge‐coupled device detectors with typical readout times of several seconds. Showing no readout noise the PILATUS detector enables measurements of samples that either display fast dynamics or possess only low scattering power with an unprecedented signal‐to‐noise ratio.  相似文献   

17.
A GE Revolution 41RT flat‐panel detector (GE 41RT) from GE Healthcare (GE) has been in operation at the Advanced Photon Source for over two years. The detector has an active area of 41 cm × 41 cm with 200 µm × 200 µm pixel size. The nominal working photon energy is around 80 keV. The physical set‐up and utility software of the detector system are discussed in this article. The linearity of the detector response was measured at 80.7 keV. The memory effect of the detector element, called lag, was also measured at different exposure times and gain settings. The modulation transfer function was measured in terms of the line‐spread function using a 25 µm × 1 cm tungsten slit. The background (dark) signal, the signal that the detector will carry without exposure to X‐rays, was measured at three different gain settings and with exposure times of 1 ms to 15 s. The radial geometric flatness of the sensor panel was measured using the diffraction pattern from a CeO2 powder standard. The large active area and fast data‐capturing rate, i.e. 8 frames s?1 in radiography mode, 30 frames s?1 in fluoroscopy mode, make the GE 41RT one of a kind and very versatile in synchrotron diffraction. The loading behavior of a Cu/Nb multilayer material is used to demonstrate the use of the detector in a strain–stress experiment. Data from the measurement of various samples, amorphous SiO2 in particular, are presented to show the detector effectiveness in pair distribution function measurements.  相似文献   

18.
A multiple‐analyser‐crystal spectrometer for non‐resonant inelastic X‐ray scattering spectroscopy installed at beamline ID16 of the European Synchrotron Radiation Facility is presented. Nine analyser crystals with bending radii R = 1 m measure spectra for five different momentum transfer values simultaneously. Using a two‐dimensional detector, the spectra given by all analysers can be treated individually. The spectrometer is based on a Rowland circle design with fixed Bragg angles of about 88°. The energy resolution can be chosen between 30–2000 meV with typical incident‐photon energies of 6–13 keV. The spectrometer is optimized for studies of valence and core electron excitations resolving both energy and momentum transfer.  相似文献   

19.
The developed curved image plate (CIP) is a one‐dimensional detector which simultaneously records high‐resolution X‐ray diffraction (XRD) patterns over a 38.7° 2θ range. In addition, an on‐site reader enables rapid extraction, transfer and storage of X‐ray intensity information in ≤30 s, and further qualifies this detector to study kinetic processes in materials science. The CIP detector can detect and store X‐ray intensity information linearly proportional to the incident photon flux over a dynamical range of about five orders of magnitude. The linearity and uniformity of the CIP detector response is not compromised in the unsaturated regions of the image plate, regardless of saturation in another region. The speed of XRD data acquisition together with excellent resolution afforded by the CIP detector is unique and opens up wide possibilities in materials research accessible through X‐ray diffraction. This article presents details of the basic features, operation and performance of the CIP detector along with some examples of applications, including high‐temperature XRD.  相似文献   

20.
Abstract: Microplasma is a useful detector for analyzing the effluent of gas chromato-graphy due to its remarkable capacity for portability, high sensitivity, and excellent multielement selectivity. Compared to classical detectors, microplasma detectors have the advantages of small size, low cost, and low energy consumption in design and operation. We aim to provide an overview of microplasma detectors and show their applications in various chemical analyses. The operational characteristics and analytical performance of different microplasma detectors, such as capacitively coupled microplasma, glow discharge microplasma, and microhollow-cathode microplasma, are presented in detail to reveal the current status of microplasma detectors for gas chromatography. In addition, several approaches for the design of microplasma are discussed and the future trends in the development of microplasma detectors are highlighted at the end of this review. Various applications of microplasma detectors for gas chromatography systems are also presented in this review.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号