首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
We propose a technique for measuring the nonlinear refractive index of fiber based on transmission-coefficient measurements in a fiber Sagnac interferometer. In contrast with traditional methods, the proposed method uses a single optical source operating in cw mode and direct intensity measurement, enabling one to avoid the errors caused by fiber dispersion and uncertainty of spectral peak difference measurements that occur with pulse-based methods. The nonlinear refractive index in 20-mol. % GeO(2) fiber was measured to be (3.1 +/- 0.2) x 10(-16) cm(2) W(-1) at 1064 nm.  相似文献   

2.
Under strong laser illumination, few-layer graphene exhibits both a transmittance increase due to saturable absorption and a nonlinear phase shift. Here, we unambiguously distinguish these two nonlinear optical effects and identify both real and imaginary parts of the complex nonlinear refractive index of graphene. We show that graphene possesses a giant nonlinear refractive index n(2)?10(-7) cm(2) W(-1), almost 9 orders of magnitude larger than bulk dielectrics. We find that the nonlinear refractive index decreases with increasing excitation flux but slower than the absorption. This suggests that graphene may be a very promising nonlinear medium, paving the way for graphene-based nonlinear photonics.  相似文献   

3.
We present a novel needle-based device for the measurement of refractive index and scattering using low-coherence interferometry. Coupled to the sample arm of an optical coherence tomography system, the device detects the scattering response of, and optical path length through, a sample residing in a fixed-width channel. We report use of the device to make near-infrared measurements of tissues and materials with known optical properties. The device could be used to exploit the refractive index variations of tissue for medical and biological diagnostics accessible by needle insertion.  相似文献   

4.
Using the phenomenon of total internal reflection and a beam splitting device, a technique of simultaneous phase-shift interferometry is proposed for measuring the full-field refractive index. Because this method applies a beam splitting device that mimics the characteristics of beam splitting and phase modulation, four interferemetric images of various phase distributions can be simultaneously captured. Therefore, this setup can avoid errors caused by non-simultaneous capturing of images and offers the benefits of high stability, ease of operation, and real-time measurement. Furthermore, using the phenomenon of total internal reflection, the phase difference between p- and s-polarized light varies considerably with the refractive index of a tested specimen. This can substantially increase the measurement resolution. The feasibility of this method is verified using an experiment, and the measurement resolution can be higher than 3.65 × 10−4 RIU.  相似文献   

5.
Baba JS  Boudreaux PR 《Optics letters》2012,37(9):1520-1522
Multispectral refractometers typically measure refractive index (RI) at discrete monochromatic wavelengths via a serial process. We report on the demonstration of a white light full-field imaging-based refractometer capable of instantaneous multispectral measurement of absolute RI of clear liquid-gel samples across the entire visible light spectrum. The broad optical bandwidth refractometer is capable of hyperspectral measurement of RI in the range 1.30-1.70 between 400 and 700 nm with a maximum error of 0.0036 units (0.24% of actual) at 414 nm for an η=1.50 sample. We present system design and calibration method details as well as results from a system validation sample.  相似文献   

6.
We demonstrate the feasibility of fabricating light-waveguiding microstructures in bulk single-crystal diamond by means of direct ion implantation with a scanning microbeam, resulting in the modulation of the refractive index of the ion-beam damaged crystal. Direct evidence of waveguiding through such buried microchannels is obtained with a phase-shift micro-interferometric method allowing the study of the multimodal structure of the propagating electromagnetic field. The possibility of defining optical and photonic structures by direct ion writing opens a range of new possibilities in the design of quantum-optical devices in bulk single-crystal diamond.  相似文献   

7.
Precision measurement of the refractive index of air with frequency combs   总被引:1,自引:0,他引:1  
Zhang J  Lu ZH  Wang LJ 《Optics letters》2005,30(24):3314-3316
We report an experimental method for high-precision refractive index measurement using a Michelson interferometer setup with a femtosecond optical frequency comb as the light source. We demonstrate this technique by measuring the refractive index of air, under different pressures, inside a 29 m multipass cell. Both spectral and temporal interferograms are recorded. The method has a sensitivity of 6.2 x 10(-9) and a standard error of 7.4 x 10(-8) at fixed parameters (pressure and temperature). The possible variation of the density factor from the Lorentz-Lorenz equation is also discussed.  相似文献   

8.
In this paper, the accuracy of the numerical reconstruction of a fiber (or fiber preform) refractive index profile from the deflection function is investigated. A few methods of numerical reconstruction are proposed and compared with respect to accuracy and efficiency. The optimum algorithm is chosen for minimizing the reconstruction error and on-axis error that result from uncertainty of the data reading.  相似文献   

9.
大气气溶胶消光特性和折射率的测量   总被引:6,自引:0,他引:6       下载免费PDF全文
 介绍了一种综合利用能见度仪、微脉冲激光雷达和光学粒子计数器测量大气气溶胶折射率的新方法。首先使用能见度仪和激光雷达测量出大气气溶胶的消光系数和消光后向散射比,然后使用粒子计数器测量出粒子谱分布,结合气溶胶粒子折射率,根据球形粒子的米(Mie)散射理论,可以得到气溶胶消光系数和消光后向散射比。通过分析消光系数、消光后向散射比、粒子谱分布和折射率之间的关系,结合已知的消光系数和消光后向散射比,反演出大气气溶胶粒子的折射率。  相似文献   

10.
介绍了一种综合利用能见度仪、微脉冲激光雷达和光学粒子计数器测量大气气溶胶折射率的新方法。首先使用能见度仪和激光雷达测量出大气气溶胶的消光系数和消光后向散射比,然后使用粒子计数器测量出粒子谱分布,结合气溶胶粒子折射率,根据球形粒子的米(Mie)散射理论,可以得到气溶胶消光系数和消光后向散射比。通过分析消光系数、消光后向散射比、粒子谱分布和折射率之间的关系,结合已知的消光系数和消光后向散射比,反演出大气气溶胶粒子的折射率。  相似文献   

11.
Fringes of equal chromatic order in transmission across a thin liquid or a thin solid sample inside a wedge interferometer, followed with a grating spectrograph, are produced. A single-shot interferogram of the air and sample regions is recorded. Locations of fringes maxima in the air region are fitted in a numerical procedure based on Cauchy's dispersion function. Then it is used for measuring the interferometric gap thickness. The order of interference in the sample region is represented by a third-order polynomial in the wavenumber for deducing the sample group refractive index. An error analysis of the measured group refractive index is given. The method is applied for measuring the group refractive index of water and mica samples across the visible spectrum. The method measures both the sample thickness and its group refractive index. It is static with no moving parts and suitable for thin liquid or solid samples without immersion liquids.  相似文献   

12.
熊芬  胡中文  姜明达 《应用光学》2012,33(1):148-152
常用的测量折射率的方法如偏向角法、自准直法、临界角法、 V棱镜法等,这些方法通常需特制三棱镜与待测件。待测样品不一致且过程复杂,测试定标周期长,难于自动化。为了保证待测材料的完整及实现自动化测量,进行了基于平行平板的折射率非接触测量的尝试。运用该方法进行折射率的测量,不需特制三棱镜并且待测件与待测样品一致。分析表明,通过选择合适的测量角度,该方法旋转角度精度为a=0.003(即10),导轨精度为L=0.000 8 mm,平行平板厚度测量精度为d=0.001 mm。  相似文献   

13.
This study introduced the research and development of a portable and miniaturized system for the measurement of the refractive index of sub-microliter liquid based on a microfluidic chip. A technical method of double-beam interference, was proposed for use in the measurement. Based on this, by using a laser diode as a light source,changes in the refractive index were calculated by utilizing a complementary metal–oxide–semiconductor to detect the movement of interference fringes of the liquid. Firstly, this study simulated the effects of influencing factors on the interference infringes of two Gaussian beams, such as their spot sizes, distance between two beam spots, and detection range. Secondly, this research introduced the system design and construction of the doublebeam interference method and analyzed the results of refractive index tests on sub-microliter aqueous glucose solutions with different concentrations. The measurement accuracy reached 10~(-4) refractive index units. This system has a compact structure and is rendered portable by using batteries for its power supply. The entire system is designed to be a double Z-shaped structure with a length of about 15 cm, a width of 5 cm, and a height of about 10 cm. It can be used to measure changes in the refractive index of sub-microliter to nanoliter liquids based on the use of a microfluidic chip.  相似文献   

14.
本文叙述了折射近场法(简称RNF)测量光纤折射率剖面的基本原理及实验方法.提供了对单模光纤和多模光纤的测量结果,并与反射法、近场法进行了比较.实验中获得空间分辨率优于0.8μm,折射率灵敏度优于2×10~(-4).  相似文献   

15.
测劈尖角度及折射率的研究   总被引:1,自引:1,他引:0  
赵斌  何雄韬 《大学物理》2004,23(4):28-30
介绍了一种利用光的干涉测量劈尖角度及折射率的方法。  相似文献   

16.
The group refractive index of BK-7 glass material is accurately measured using a tandem low-coherence interferometer, which is composed of a Mychelson interferometer and a Fizeau interferometer, within a combined standard uncertainty of 8.4 ppm. The experimental results are compared with the value calculated from the conventional data base on the phase refractive index, within a difference of about 4.7 ppm. This new method is applicable to in situ measurement due to the principle of its common optical path.  相似文献   

17.
刘爱梅  吕昊 《光学技术》2008,34(3):476-478
自麦克斯韦鱼眼透镜理论模型提出后,长期以来学术界一直以为它只是一种绝对光学仪器,在实践中并没有应用的可能。但通过对麦克斯韦鱼眼微球透镜的理论研究表明,在一定条件下,它具有良好的成像性能和耦合效率。根据菲克定律推导出梯度折射率球透镜的折射率分布函数。并且熔制了含Li+硅酸盐玻璃和采用槽沉法以及Na+/Li+离子交换法制备直径为0.3—3.0mm的梯度折射率球透镜。通过干涉法测得了梯度折射率球透镜的折射率分布曲线,并研究了光线通过梯度折射率球透镜的轨迹。研究结果表明:在590℃,离子扩散系数为3.07×10-6mm2/s;所制备的梯度折射率球透镜的折射率分布是抛物线分布,并且和理论分析相吻合;梯度折射率球透镜的光线轨迹满足椭圆方程。  相似文献   

18.
An approach to the simultaneous measurement of refractive-index(RI) and temperature changes using optical ring resonators is proposed and theoretically demonstrated.With a liquid-core silica ring resonator as an example,two different-order whispering gallery modes(WGMs) might differ in not only RI but also temperature sensitivities.Thus,a second-order sensing matrix should be defined based on these WGMs to determine RI and temperature changes simultaneously.The analysis shows that the RI and temperature detection limits can be achieved on the order of 10 7 RI unit and 10 3 K at a wavelength of approximately 780 nm.  相似文献   

19.
用表面等离子波相位检测法测量液体折射率   总被引:6,自引:0,他引:6  
蒋弘 《光学技术》2000,26(1):41-42,45
表面等离子体波(SPW) 检测技术近年来已被应用在生物传感领域。它通过探测介质的折射率变化来探测生物反应。理论分析表明,利用SPW 相位检测的方法可以实现高分辨率的液体折射率测量。在优化测量参数的基础上,使用低频差横向塞曼激光器为光源,进行了验证实验,实验结果与理论相符合。  相似文献   

20.
Zhang J  Lu ZH  Wang LJ 《Optics letters》2007,32(21):3212-3214
We report a higher precision measurement of the refractive index of carbon dioxide using a frequency comb as the light source in a Mach-Zehnder interferometer setup. The experimental sensitivity can reach the level of 8.8x10(-9). Taking into account the measurement accuracy of temperature and pressure, the experimental accuracy has a value of 1.2x10(-8). The measurement result has a deviation from the commonly quoted result [Old , J. Opt. Soc. Am.61, 89 (1971)] by 6.4x10(-7) at 800 nm.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号