首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 484 毫秒
1.
Poly(N-isopropylacrylamide), one of the most utilized thermoresponsive polymers, brush-grafted monolithic-silica columns were prepared through surface-initiated atom transfer radical polymerization (ATRP) for effective thermoresponsive-chromatography matrices. ATRP initiator was grafted on monolithic silica-rod surfaces by flowing a toluene solution containing ATRP initiator into monolithic silica-rod columns. N-Isopropylacrylamide (IPAAm) monomer and CuCl/CuCl(2)/Me(6)TREN, an ATRP catalytic system, were dissolved in 2-propanol, and the reaction solution was pumped into the preprepared initiator-modified columns at 25 °C for 16 h. The constructed PIPAAm-brush structure on the monolithic silica-rod surface was confirmed by XPS, elemental analysis, SEM observation, and GPC measurement of grafted PIPAAm. The prepared monolithic silica-rod columns were also characterized by chromatographic analysis. PIPAAm-brush-modified monolithic silica-rod columns were able to separate hydrophobic steroids with a short analysis time (10 min), compared to PIPAAm-brush-modified silica-beads-packed columns, because of the horizontally limited diffusion path length of monolithic supporting materials. Additionally, diluted PIPAAm-brush monolithic silica-rod column gave a further shorting analysis time (5 min). These results indicated (1) surface-initiated ATRP constructed PIPAAm-brush structures on monolithic silica-rod surfaces and (2) PIPAAm-brush grafted monolithic silica-rod column prepared by ATRP was a promising tool for analyzing hydrophobic-bioactive compounds with a short analysis time.  相似文献   

2.
整体柱离子色谱的研究进展   总被引:1,自引:0,他引:1  
陈倩  于泓 《分析测试学报》2011,30(6):705-712
该文介绍了离子色谱的分类,整体柱的分类、制备及特点,并以此为依据归纳总结了常规整体柱在离子色谱中的应用和毛细管整体柱在毛细管离子色谱中的应用,其中包括硅胶基质整体柱和聚合物基质整体柱,评述并展望了整体柱离子色谱的发展前景.  相似文献   

3.
弱阴离子交换硅胶整体柱的制备及其电色谱性能   总被引:8,自引:0,他引:8  
采用溶胶-凝胶法,结合超分子模板技术,制备了一类新型有机-无机杂化硅胶离子交换整体柱。采用扫描电镜对整体柱的微观结构加以表征,证实孔结构均匀。将制备的弱阴离子交换整体柱应用于9种有机酸的分离,获得最高19万塔板数/米的柱效。探讨了pH值和有机改性剂浓度对分离的影响。  相似文献   

4.
Yan F  Chen B 《色谱》2011,29(5):426-429
以硅酸钾为硅源,甲酰胺为催化剂在毛细管内原位聚合形成干凝胶柱,制备了一系列致密度不同的整体柱。该法在柱制备及高温干燥过程中不会发生柱床断裂和塌陷现象,此特点明显优于以烷氧基硅烷为前驱体制备无机整体柱的方法。考察了不同模数硅酸钾对整体柱柱床结构的影响,用扫描电镜(SEM)和氮吸附法对整体柱结构进行了表征,考察了整体柱柱压与流速的关系;对整体柱进行十八烷基修饰后,测定了反相整体柱(C18整体柱)对蒽的柱效,通过考察甲苯在该柱上的突破曲线,获得了其对甲苯的柱容量。结果显示该整体柱柱床刚性好,在高温、高柱压、高流速时柱床能保持其物理结构的稳定性,对蒽的柱效达到41400理论塔板/m,对甲苯的柱容量为61 ng。  相似文献   

5.
介绍了毛细管电色谱开管柱、填充柱和整体柱的各种制备技术及其优势与不足,特别是对于近期发展的毛细管电色谱整体柱的制备方法及其应用进行了系统综述。引用文献100篇。  相似文献   

6.
Wu R  Zou H  Fu H  Jin W  Ye M 《Electrophoresis》2002,23(9):1239-1245
The mixed mode of reversed phase (RP) and strong cation-exchange (SCX) capillary electrochromatography (CEC) based on a monolithic capillary column has been developed. The capillary monolithic column was prepared by in situ copolymerization of 2-(sulfooxy)ethyl methacrylate (SEMA) and ethylene dimethacrylate (EDMA) in the presence of porogens. The sulfate group provided by the monomer SEMA on the monolithic bed is used for the generation of the electroosmotic flow (EOF) from the anode to the cathode, but at the same time serves as a SCX stationary phase. A mixed-mode (RP/SCX) mechanism for separation of peptides was observed in the monolithic column, comprising hydrophobic and electrostatic interaction as well as electrophoretic migration at a low pH value of mobile phase. A column efficiency of more than 280,000 plates/m for the unretained compound has been obtained on the prepared monoliths. The relative standard deviations observed for t(0) and retention factors of peptides were about 0.32% and less than 0.71% for ten consecutive runs, respectively. Effects of mobile phase compositions on the EOF of the monolithic column and on the separation of peptides were investigated. The selectivity on separation of peptides in the monolithic capillary column could be easily manipulated by varying the mobile phase composition.  相似文献   

7.
以蜂窝陶瓷为载体、γ-Al2O3为惰性涂层、C301/HZSM-5为活性组分制备出一种整体式合成二甲醚催化剂。BET、XRD和SEM分析结果表明,活性组分均匀负载在载体表面上,催化剂具有良好的结构和织构特点。在固定床反应器中考察了整体式催化剂上CO加氢一步法合成二甲醚的反应性能,并与C301/HZSM-5颗粒(粉末)催化剂进行了比较。在温度260℃、压力4.0MPa、合成气空速1500mL/(g·h)的条件下,整体式催化剂上CO转化率达到79.62%,二甲醚选择性为70.58%,分别比C301/HZSM-5颗粒催化剂高出7.78%和9.44%。100h的稳定性实验结果表明,整体式催化剂可以保持较高的活性和选择性,而颗粒状催化剂的活性有明显的下降。
  相似文献   

8.
采用溶胶-凝胶法,以四乙氧基硅烷和苯基三乙氧基硅烷作为反应单体,通过酸碱两步催化在毛细管中进行原位缩聚反应,制备了新型有机-无机杂化硅胶基质毛细管整体柱,制备过程简单。整体柱基质中均匀分布的苯基基团可直接用于反相毛细管电色谱的分离,因而不需要对基质再进行衍生化。优化了整体柱的制备条件,采用扫描电镜和压汞法对整体柱的微观结构和孔径分布进行了表征。分别考察了溶胶-凝胶初始反应液中水的用量对柱床结构的影响和两种单体的配比对材料孔径分布的影响。研究了稠环芳烃类化合物在整体柱上的保留行为,用所制备的整体柱分离了7种苯酚类化合物,平均柱效达100000塔板/m。  相似文献   

9.
Monolithic columns invented in chromatographic praxis almost 40 years ago gained nowadays a lot of popularity in separations by liquid chromatographic technique. At the same time, application of monolithic columns in gas chromatography is less common and only a single review published by Svec et al. [1] covers this field of research. Since that time a lot of new findings on application and properties of monolithic columns in gas chromatography have been published in the literature deserving consideration and discussion. This review considers preparation of monolithic columns for GC, an impact of preparation conditions on column performance, optimization of separation conditions for GC analysis on monolithic columns and other important aspects of preparation and usage of monolithic capillary columns in GC. A final part of the review discusses the modern trends and possible applications in the future of capillary monolithic columns in GC.  相似文献   

10.
Wang J  Wang X  Li J  Lü H  Lin X  Xie Z  Zhang Q 《色谱》2011,29(12):1222-1229
采用N-丙烯酰琥珀酰亚胺(NAS)为基质单体,乙二醇二甲基丙烯酸酯(EDMA)为交联剂,原位聚合制备聚(NAS-co-EDMA)毛细管整体柱,并通过化学键合法将自合成的纤维素-三(4-甲基苯甲酸酯)(CTMB)共价键合到整体柱上,制备用于快速手性分离的纤维素键合型手性整体柱.优化了整体柱制备和衍生化条件;通过对固定相红...  相似文献   

11.
用共浸渍法制备了Co-Ni2P/SBA-15前躯体,将其调制成活性胶后均匀涂覆到预处理后的堇青石载体上,程序升温还原后制备了一系列Co-Ni2P/SBA-15/堇青石整体式催化剂。采用XRD、N2吸脱附和XPS等对催化剂进行了表征,以1 wt%二苯并噻吩(DBT)/十氢萘溶液为模型化合物,在微型固定床反应器上对催化剂的加氢脱硫(HDS)性能进行了评价。结果表明,不同Co含量的Co-Ni2P/SBA-15/堇青石整体式催化剂中都形成了Ni2P相。Co的加入提高Ni2P/SBA-15/堇青石催化剂的比表面积和孔体积。Co含量为0.55wt%的Co-Ni2P/SBA-15/堇青石整体式催化剂有最好的二苯并噻吩加氢脱硫活性,在380℃,二苯并噻吩转化率能够达到98.8%。Co的加入能够提高二苯并噻吩直接加氢脱硫产物联苯的选择性。  相似文献   

12.
In this study, eight benzophenones, which are commonly used as UV filters in various cosmetics and plastics, were analyzed by capillary electrochromatography with a methacrylate ester-based monolithic column. The effects of the composition and pH of mobile phase, porogenic solvent ratio, and 2-acrylamido-2-methyl-1-propanesulfonic acid (AMPS) content on benzophenone separations were examined. For all benzophenones, separation performances were markedly improved in monolithic columns with larger 1-propanol ratio and higher AMPS content. Furthermore, a twofold increase in AMPS content almost reduced the separation time in half when a monolithic column had an adequately high surface area, i.e. monolithic column was produced in a higher ratio of 1-propanol. As well, the retention behaviors of these analytes in the monolithic column were strongly influenced by the level of acetonitrile in the mobile phase, and the pH of the mobile phase also had an apparent influence on separation resolution.  相似文献   

13.
A novel monolithic silica column that has a polar‐embedded amide‐secondary amine group linking with C16 functionality for RP‐CEC is described. The amide‐secondary aminealkyloxysilane was synthesized by the reaction of 3‐(2‐aminoethylamino) propyltrimethoxysilane with hexadecanoyl chloride. Then, the silylant agent was bonded to the silica monolith matrix to produce hexadecanamide‐secondary amine bonded silica (HDAIS) monolithic column. The electrochromatographic performance of HDAIS monolithic column for the separation of neutral, basic and polar solutes was studied, which was compared to that using the hexadecyl bonded silica monolithic column. The HDAIS monolithic column displayed reduced hydrophobic retention characteristics in the separation of five hydrophobic n‐alkylbenzenes and four polar phenols when compared to the hexadecyl bonded silica monolithic column. A very much reduced silanol activity of HDAIS monolithic column was observed in the separation of test basic mixture including four aromatic amines, atenolol and metoprolol with 10 mM borate buffer (pH 7.5) containing 30% v/v ACN as the mobile phase. The comparison results indicate good performance for both polar and basic mixtures on HDAIS monolithic column in RP‐CEC, and also show promising results for further applications.  相似文献   

14.
Molecularly imprinted polymeric monolithic fiber is a new technique of solid-phase microextraction that focuses on selectivity. However, the inner mechanism of increasing the selectivity is not well understood. Here, a new approach to improve the selectivity is shown through controlling the surface of a molecular imprinted polymeric monolithic fiber. Sulfadimidine-imprinted polymeric monolithic fibers were fabricated using two kinds of molds, the polytetrafluoroethylene capillary and the silica capillary. A mixture of sulfadimidine, sulfamerazine, sulfadiazine, and sulfametoxypirydazine was used to test the selectivity of the fibers to sulfadimidine. This paper demonstrates that the extraction ratio for sulfadimidine in mixture is increased to more than 150% in sulfadimidine-imprinted polymeric monolithic fiber compared to nonimprinted polymeric monolithic fiber. The extraction ratio is increased to about 30% in sulfadimidine-imprinted polymeric monolithic fiber fabricated from silica capillary than in the counterpart from nonimprinted polymeric monolithic fiber. The sulfadimidine-imprinted polymeric monolithic fibers were also applied to extract standard mixtures spiked into Pearl River water and milk. The results indicated that polytetrafluoroethylene-sulfadimidine imprinted polymeric monolithic fiber showed highest selectivity to sulfadimidine in complex samples.  相似文献   

15.
A novel (3‐sulfopropyl methacrylate potassium)‐silica hybrid monolithic column for CEC has been prepared by a simple one‐pot approach based on efficient thiol‐ene click chemistry. In this process, the polycondensation of hydrolyzed alkoxysilanes and in situ click reaction of vinyl groups on 3‐sulfopropyl methacrylate potassium and thiol groups on the precondensed siloxanes simultaneously occurred in a pretreated capillary. Homogeneous monolithic matrix with large through‐pores tightly bonded to the inner wall of the capillary was shown by optical microscope and SEM. The minimum plate height of this hybrid monolithic column was determined as 3.9 μm for thiourea. Anilines, alkylbenzenes, and phenols were well separated on this hybrid monolithic column by CEC, which indicated typical reversed‐phase and cation‐exchange chromatographic retention mechanisms of the column.  相似文献   

16.
A monolithic molecularly imprinted polymer (monolithic MIP) was designed and prepared for chiral separation of nateglinide and its L-enantiomer. The enantiomers were rapidly separated on this novel monolithic MIP based chiral stationary phase (MIP-CSP), whereas the enantioseparation was not obtained on the non-imprinted polymer (NIP). Chiral recognition was found to be dependent on the stereo structures and the arrangement of functional groups of the imprinted molecule and the cavities on MIP. Thermodynamic data (deltadeltaH and deltadeltaS) obtained by Van't Hoff plots revealed an enthalpy-controlled enantioseparation. The binding capacity was evaluated by frontal analysis. Monolithic nateglinide-MIP had an effective number of binding sites Bt = 41.15 micromol g(-1) with a dissociation constant of Kd = 7.40 mM. The morphological characteristics of the monolithic MIP were investigated by pore analysis and scanning electron microscope (SEM). Results showed that both mesopores and macropores were formed in the monolith. Over all, this study presents a new and practical possibility for providing high rates of mass transfer, fast separations and high efficiencies without the pressure constraints of the traditional bulk molecularly imprinted polymers, through the monolithic MIPs.  相似文献   

17.
A silica-bonded bovine serum albumin (BSA) chiral monolithic stationary phase for capillary electrochromatography(CEC) was introduced. An inorganic-organic hybrid monolithic column was firstly prepared by sol-gel chemistry with homogeneously distributed aminopropyl groups throughout the silica matrix. Then the chiral stationary phase was synthesized by the in situ covalent immobilization of BSA on the monolithic column activated with glutaraldehyde. The effects of pH value and concentration of phosphate buffer on the separation of D,L-tryptophan were investigated. The separation factor of D,L-tryptophan reached 3.37 on CEC mode.  相似文献   

18.
A convection interaction media (trade name CIM, BIA Separation, Ljubljana, Slovenia) isobutyl monolithic disc was prepared by incubating a CIM epoxy monolithic disc with isobutylamine, and it was then applied to the purification of secondary alcohol dehydrogenase (S-ADH) and primary alcohol oxidase (P-AOD). Both enzymes were adsorbed on this column and eluted with high purity. Thus, S-ADH was purified to an electrophoretically homogeneous state by four column chromatographies using CIM DEAE-8 and CIM C4-8 tube monolithic columns, blue-Sepharose column and CIM isobutyl disc monolithic column. P-AOD was also purified to an electrophoretically homogeneous state by three column chromatographies of CIM DEAE-8 tube, CIM C4-8 tube and CIM isobutyl disc columns.  相似文献   

19.
We developed a novel, convenient and low-cost one-pot strategy for preparing a zeolitic imidazolate framework-8 (ZIF-8)–silica hybrid monolithic column by adding ZIF-8 directly to a polymer solution of the silica matrix. The simulated stationary phase and monolithic column prepared under optimal conditions were characterized using X-ray diffraction, scanning electron microscopy, Fourier-transform infrared spectroscopy, thermogravimetric analysis nitrogen physisorption and zeta potential. The results obtained confirmed the successful introduction of ZIF-8 into the silica monolithic column, and the prepared monolithic column exhibited good permeability and physicochemical stability. A capillary electrochromatography method was developed based on a ZIF-8–silica hybrid monolithic column through which 15 mixed amino acids, 4 neutral compounds, 4 nipagin esters and 2 chlorinated fungicides were separated in 14, 5, 7 and 6 min, respectively, under optimal conditions. The relative standard deviations retention times and column efficiencies in run-to-run, day-to-day and column-to-column varied in the ranges of 1.90%–2.21%, 2.13%–2.51% and 3.08%–6.65%, respectively, which demonstrated that ZIF-8–silica hybrid monolithic column exhibited satisfactory reproducibility and stability. The incorporation of ZIF-8 into a silica monolithic column is a promising method for preparing novel monolithic columns composed of a metal–organic framework.  相似文献   

20.
以苯基三乙氧基硅烷(PTES)和1,4-双三乙氧基硅基苯(BTEB)为反应单体,分别采用盐酸和十二胺为催化剂,通过两步酸碱催化的溶胶-凝胶法制备了新型双苯基杂化硅胶毛细管电色谱整体柱。分别采用扫描电镜、红外光谱和压汞法对材料的结构特性进行了表征。结果表明,所制备的材料具有特定的网络结构特征,孔径主要分布在3.4μm左右,材料的总孔容为3.5 cm3/g,比表面积为145 m2/g。新型整体柱能够很好地分离烷基取代苯、稠环芳烃、取代苯胺和硝基苯酚异构体。整体柱重复性实验表明,6种苯的同系物保留时间和容量因子的相对标准偏差分别小于0.61%和0.30%(n=8)。不同批次的整体柱的保留时间和容量因子的相对标准偏差分别小于7.2%和5.6%(n=3)。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号