首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A new method of SS-RTP for the determination of trace silver has been established. This method is based on the fact that Ag+, when activated by ,-bipyridyl (bipy) in a media of HAc–NaAc (pH=4.9), can catalyze the reaction of Rhodamine B (RhoB) oxidized by K2S2O8, thus causing the Solid Substrate Room-Temperature Phosphorescence (SS-RTP) of RhoB to be quenched. The activating efficiency of bipy is 6.7 times higher than that of o-phenanthroline (phen). The reduction of the phosphorescence intensity (Ip) of RhoB is directly proportional to the concentration of Ag+ ions in the range of 1.6016.0agspot–1 (0.40µLspot–1). The regression equation of the working curve can be expressed as Ip=18.78+5.100mAg+ (agspot–1) (r=0.9994, n=6), the detection limit is 0.28agspot–1. This rapid, accurate and sensitive method has been successfully applied to the determination of trace silver in tea and human hair samples, and the results agree well with the Atomic Absorption Spectroscopy (AAS) method. The mechanism of the catalyzing reaction is also discussed.  相似文献   

2.
A sub-micrometer thin-layer DNA modified carbon fiber microcylinder electrode was prepared by electrodeposition of ct-DNA at 1.5V (vs. Ag/AgCl). The voltammetric behavior of dopamine (3-hydroxytyramine) was investigated at the modified electrode. It was found that the modified electrode exhibits a highly electrocatalytic activity toward dopamine oxidation. Differential pulse voltammetry was used for determination of dopamine in pH 7.4 phosphate buffer solution. A linear response of the peak current versus the concentration was found in the range of 4×10–6 to 10–4molL–1 at 10–4molL–1 AA (ascorbic acid) coexistence (R=0.9959) and the range of 6×10–5 to 10–3molL–1 at 10–3molL–1 AA (R=0.9960). The presence of a high concentration of ascorbic acid did not interfere with the determination. The proposed method exhibited good recovery and reproducibility. This method can be applied to the detection of DA in real samples.  相似文献   

3.
A simple and novel electrogenerated chemiluminescence (ECL) method for the determination of sulfite has been developed based on the energy transfer ECL process. It was found that a weak ECL signal of sulfite was electrochemically generated on a platinum electrode in neutral aqueous solution. The signal was strongly enhanced by rhodamine B as an energy receptor and further enhanced by the neutral surfactant Tween 80. In 0.10M phosphate buffer solution (pH=7.5) containing 2.0×10–6gmL–1 rhodamine B and 0.4% (v/v) Tween 80, the ECL response to the concentration of sulfite at a potential of 0.82V was linear over a range of 1.0×10–7gmL–1 to 8.0×10–6gmL–1, and the detection limit was 5×10–8gmL–1. The relative standard deviation (n=11, 1.0×10–6gmL–1) was 3.8%. The proposed method has been successfully applied to the determination of sulfite in pharmaceutical injections and white sugar samples.  相似文献   

4.
A new macrocyclic ligand, 1,4,8,11-tetraazacyclotetradecane-1,8-bis(methylphosphonic acid) (refered to as dipon) exhibits high thermodynamic and kinetic selectivity for Cu2+ compared to other transition metal ions. The initial-rate method (=310nm, pH=3.75, cL4.6×10–3molL–1) was chosen as an optimal experimental approach in order to achieve maximum sensitivity of determination. The dynamic range of the method is (5–200)×10–6molL–1, and the detection limit is 2.5×10–6molL–1. A standard addition procedure was applied to the kinetic determination of Cu2+ to eliminate the effect of interfering ions (e.g. Zn2+, Ca2+, Mg2+, Cd2+, Pb2+, Mn2+, Co2+, Ni2+, HCO3, Cl, SO42–, etc.). The method was tested on artificial and real samples (alloys, pure and spiked mineral water) and gave satisfactory results which are in agreement with the values for some certified materials. The advantage of the proposed method is rapidity, simplicity and robustness in the presence of other metal ions.  相似文献   

5.
The interaction of indophenol blue (IPB) with proteins in aqueous solution has been studied by optical absorption and Rayleigh light scattering (RLS) spectroscopy. At pH 3.8, the weak RLS of IPB is enhanced by proteins. Based on this phenomenon, a novel method for the determination of proteins at nanogram levels using the RLS technique is developed. The method is simple, practical and sensitive. The linear range is 0.25–20.9µgmL–1 for BSA, and 0.25–17.6µgmL–1 for HSA. The detection limits (S/N=3) are 23ngmL–1 for BSA and 22ngmL–1 for HAS. The results for the determination of proteins in human serum samples are very close to those obtained by an established clinical method. There is very little interference from amino acids, metal ions or other coexisting compounds.  相似文献   

6.
A novel method for the determination of proteins in aqueous solutions has been developed based on the enhancement of resonance light scattering (RLS) of Ag nanoparticles in the presence of proteins. Factors including acidity of the media, concentration of Ag hydrosol, reaction time, temperature, and interference of non-protein substances were investigated. Under the optimal conditions, with the enhanced RLS signals at 452nm, the linear ranges of calibration curves were 0–0.8µgmL–1 for bovine serum albumin (BSA), 0–1.2µgmL–1 for human serum albumin (HSA), and 0–2.5µgmL–1 for human -IgG (-IgG), respectively. The detection limits were 1.3ngmL–1 for BSA, 10ngmL–1 for HAS, and 5.7ngmL–1 for -IgG.This method has been applied to the analysis of synthetic samples and real human serum samples, and the results were in good agreement with those reported by the hospital, indicating that the method presented here is not only sensitive and simple, but also reliable and suitable for practical applications.  相似文献   

7.
A spectrophotometric method for the selective determination of Al(III) in the presence of Be and Ln (lanthanide) cations is proposed. It is based on the selective reaction of SXO (Semi-Xylenol Orange) with Al(III) at pH 2.6. The presence of 8%v/v of 1,2-ethanediol serves to stabilize the chelate formed by heating at 100°C for 5min. 0.5mg each of Be(II), Ce(III), La(III), 4mg of Mn(II), 1.2mg of Pb(II), 1mg of Tl(I), 40mg each of Ca(II) and Mg(II) and 1.9mg of sodium dihydrogen phosphate are tolerable. A ligand buffer of HEDTA-Pb is incorporated to further enhance the selectivity of the color reaction. Under the specified conditions SXO reacts with Al(III) to form a 1:1 chelate. Its molar absorptivity at 526nm was found to be 3.3×104Lmol–1cm–1. The linear regression equation for 2–20µg of Al(III) is A=0.04458C+0.0112 (where C stands for the concentration of Al(III), µg per 25mL) and correlation coefficient =0.9988. The RSD at the level of 10µg (n=10) and LOQ were found to be 3.5% and 2µg, respectively.  相似文献   

8.
A flow-injection procedure for the determination of iron(III) in water is described. The procedure is based on the formation of an ion pair between the tetraphenylarsonium (Ph4As+) (TPA) or tetrabutylammonium (But4N+) (TBA) cations and the tetrathiocyanatoferrate(III) complex (TTF). This ion pair is extracted with chloroform, and the absorbance of the organic phase is measured at 503nm (for Ph4As+) or 475nm (for But4N+). Iron concentrations higher than 0.9×10–6molL–1 (50µgL–1) can be detected in the first case, with a relative standard deviation of 1.9% (n=12), a linear application rangeof between 1.34 and 54.0×10–6molL–1 (75–3015µgL–1), and a sampling frequency of 30h–1. For the ion pair with But4N+, the detection limit is 0.52×10–6molL–1 (29µgL–1), with a relative standard deviation of 1.6% and a linear application range between 0.73 and 54.0×10–6molL–1. Under the proposed working conditions, only Pd(IV), Cu(II) and Bi(III) interfere. With the application of the merging zones technique, considerable amounts of organic reagent can be saved. The TBA method was applied to the analysis of iron(III) in tap and industrial waste waters.  相似文献   

9.
A microcolumn on-line preconcentration and separation system was developed for the flame atomic absorption spectrometric (FAAS) determination of trace levels of gold and palladium. The analytes were selectively adsorbed onto the microcolumn packed with 2-mercaptothiazole immobilized silica gel (MBTSG) in an acidity range of 0.1 to 6.0M HCl at a sampling flow rate of 4.0mLmin–1. The analytes adsorbed could be desorbed by a thiourea solution with a flow rate of 2.0mLmin–1. Most of the common coexisting metal ions at a concentration of 25.0mgmL–1 and anions at a concentration of 50.0mgmL–1 did not interfere with the preconcentration and determination of Au and Pd. The limits of detection (LOD), defined as three times the standard deviation of the blank (3), of Au and Pd are 10ngmL–1 and 26ngmL–1, respectively, with a preconcentration time of 60s. The relative standard deviation (RSD) is about 2.0% for 0.20µgmL–1 Au and 0.30µgmL–1 Pd. With a sample loading time of 30min, 6.7ngmL–1 Au and 10ngmL–1 Pd can be preconcentrated quantitatively. A geological sample, an anode slime and a secondary nickel alloy were successfully determined with the proposed method, and the results obtained showed good agreement with the certified values.Received December 23, 2002; accepted May 14, 2003 Published online August 8, 2003  相似文献   

10.
A flow injection hydride generation graphite furnace atomic absorption spectrometric (FI-HG-GFAAS) method was applied to the determination of Se in Se-doped and undoped cereals and bakery products. For the purpose of doping, the soils used for the cultivation of the cereals were dosed with Se-doped foliar fertilizers. The samples were dissolved in a mixture of HNO3 and H2O2 solutions using microwave-assisted digestion. The decomposition of H2Se generated from the sample solutions and the trapping of elemental Se were performed at a temperature of 300°C on an Ir-pretreated integrated graphite platform of a transversally heated graphite atomizer (THGA). For release of the trapped Se within a fairly short atomization time (5s), an atomization temperature of 2200°C was observed to be optimal. The overall efficiency of hydride generation, transport and trapping was 86%.The upper limit of the linear dynamic range of calibration was 10µgL–1, which corresponds to 0.5µgg–1 for solid samples. Recovery of the samples spiked with SeVI solutions was found to be 93±6% on average. The relative standard deviation of the determinations was less than 8%. The limit of detection was found to be 0.06µgL–1, corresponding to 3ngg–1 for solid samples. The accuracy of the method was verified with the use of IAEA-155 (whey powder) certified reference material. End-capped THGA tubes resulted in an extension of the linear calibration range compared to that of standard THGAs.The Se content in bakery products made of undoped cereals ranged from 7.7 to 68ngg–1 (wet weight) in 18 samples, whereas the Se content of the corresponding cereals was found to be below 100ngg–1 (wet weight). The Se level of cereals grown on soils treated with Se-doped fertilizers ranged from 128 to 1046ngg–1 (wet weight), and it depended linearly on the Se concentration of the corresponding foliar fertilizer.  相似文献   

11.
Thallium in natural water samples was determined by electrothermal atomic absorption spectrometry after 1000-fold enrichment by mini solid-phase extraction from a 100-mL sample solution. A Tl-pyrrolidine-1-carbodithioate complex formed in a sample solution of pH 1.6 was extracted on fine particles of a cellulose nitrate resin dispersed in the sample solution. The cellulose nitrate resin was then collected on a membrane filter (25mmø) by filtration under suction using a glass funnel with an effective filtration area of 0.64cm2. As a result, a circular thin layer of the resin phase with a diameter of 9mm was obtained. Then the resin phase was carved out by an acrylate resin puncher with a 10-mmø hole to put it into a sample cup containing 100µL of 10mM HNO3 containing 0.5mM NaCl. The resin phase was suspended in the solution by ultrasonication. 1000-fold enrichment was thus attained within 15min, and the suspension was delivered to electrothermal atomic absorption spectrometry. The linear calibration graph was obtained in the range of 0–4ng of Tl in 100mL of a sample solution. The detection limit obtained by 3 method was 0.19ng. The proposed method was applied to the determination of Tl in natural water samples. The results showed the concentration of Tl in seawater was 12.1±1.8pgmL–1 for the calibration graph method and 12.6±1.4pgmL–1 for the standard addition method. A snowmelt sample contained 20.7±1.0pgmL–1 of Tl.  相似文献   

12.
Two different methods (one based on chromatography and spectrophotometry and the other on polarography) have been developed for the determination of glyoxylic acid in the form of a derivative with 2,4-dinitrophenylhydrazine (DNPHGA). The TLC method allows the separation of two DNPHGA isomers (trans and cis). Spectrophotometric measurements of the eluents of the separated compounds (=360 nm) allow the determination of GA within the range from 4 to 30 g. Using differential pulse polarography, the conditions of DNPHGA formation were examined. The reduction peak of this derivative (EP=–0.430 V), observed by dpp, was used to develop a polarographic determination of GA within the concentration range from 110-4 to 710–4 mol/l.  相似文献   

13.
A new ligand, 1-(2-furanthiocarbo)-3-thiosemicarbazide (H2ftsc), prepared from thiosemicarbazide and carboxymethyl-2-furandithioate, forms complexes [Mn(ftsc)(H2O)2], [Pd(ftsc)] · 2H2O, [M(Hftsc)(acac)2] (M=CoIII or CrIII), [M(Hftsc)2(acac)] (M=MnIII or FeIII) and [Zn(Hftsc)2] · 2H2O, which were characterized by elemental analyses, magnetic susceptibility, i.r., electronic and n.m.r. spectral data. The Mössbauer spectra of [Fe(Hftsc)2(acac)] at 298K and 80K suggest the presence of high-spin iron(III) with an S=5/2 state. In vivo and in vitro antitumour activity of the ligand and the complexes have been screened towards several tumour cell-lines.  相似文献   

14.
Osmocene (and decamethylosmocene) is characterized by a lowest-energy ligand field triplet which occurs at max=372nm (374nm) in absorption and 567nm (572nm) in emission. This orange–yellow phosphorescence is rather intense at 77K but is also visible at r.t.  相似文献   

15.
A simple commercial graphite pencil electrode (GPE) was utilized for monitoring caffeine using the square-wave anodic stripping voltammetry (SWASV) method. This method was applied to determine the caffeine levels in several tea samples, which yielded a relative error of 1% in the concentrations. Caffeine was deposited at 0.0V (vs. Ag/AgCl), then reduced at +1.40V to strip it on the GPE. Optimal experimental conditions for the analysis were found to be as follows: pH value of 9 for the medium; deposition potential of 0.0V; deposition time of 120s; SW frequency of 25Hz; SW amplitude of 45mV, and step potential of 6mV. Given these optimum conditions, a linear range was observed within the concentration of 0500mgL–1. At caffeine concentrations of 50.0, 250.0, and 500.0mgL–1, the relative standard deviations in measured concentrations (n=12) were 0.19, 0.09, and 0.11%, respectively. The detection limit was found to be 9.2mgL–1, which is comparable with the result obtained using a carbon paste electrode, equivalent to 8.2mgL–1.  相似文献   

16.
A new method for the simultaneous determination of heavy metal ions in Chinese herbal medicine by microwave digestion and reversed-phase high-performance liquid chromatography (RP-HPLC) has been developed. The Chinese herbal medicine samples were digested by microwave digestion. Lead, cadmium, mercury, nickel, copper, zinc, and tin ions in the digested samples were pre-column derivatized with tetra-(4-chlorophenyl)-porphyrin (T4-CPP) to form the colored chelates which were then enriched by solid phase extraction with C18 cartridge and eluted from the cartridge with tetrahydrofuran (THF). The chelates were separated on a Waters Xterra RP18 column by gradient elution with methanol (containing 0.05molL–1 pyrrolidine-acetic acid buffer salt, pH=10.0) and THF (containing 0.05molL–1 pyrrolidine-acetic acid buffer salt, pH=10.0) as mobile phase at a flow rate of 0.5mLmin–1 and detected with a photodiode array detector in the range of 350–600nm. In the original samples the detection limits of lead, cadmium, mercury, nickel, copper, zinc and tin are 4ngL–1, 3ngL–1, 6ngL–1, 5ngL–1, 2ngL–1, 6ngL–1, and 4ngL–1, respectively. This method was applied to the determination of lead, cadmium, mercury, nickel, copper, zinc and tin in Chinese herbal medicine samples with good results.  相似文献   

17.
A sensitive and selective solid phase spectrophotometric method for the determination of trace amounts of inorganic mercury is described. Hg2+ was sorbed on a silica gel-packed column as an Hg2+N,N-bis(2-mercaptophenyl)ethanediamide (H2L) complex. The Hg2+ complex was eluted from the column using 7mL of acetone. Various parameters including pH, column flow rate, and ligand concentration were optimized. The complex was found to obey Beers law from 2.3 to 73.7µgmL–1 within the optimum range when the preconcentration factor was two. The effective molar absorption coefficient at 523nm was 1.17×103Lmol–1cm–1 at 523nm. The concentration limits in Beers law dropped from 0.09 to 2.95µgmL–1 within the optimum range when the preconcentration factor was 50. The relative standard deviation at a concentration level of 5µgmL–1 Hg2+ (9 repetitive determinations) was 1.6%. The detection limits are 0.34µgmL–1 and 0.015µgmL–1 when the preconcentration factors are 2 and 50, respectively. The method has been used for routine determination of trace levels of Hg2+ in natural waters. The potential application of this method for the removal of Hg2+ from natural samples (sea water and lake water) spiked with 100ngmL–1 of Hg2+ was studied. In order to validate the proposed method, LGC 6156 (harbour sediment – extractable metals) was analysed by this method. The results proved that excellent extraction of Hg2+ from both natural water samples was obtained by solid phase extraction using N,N-bis(2-mercaptophenyl) ethanediamide.  相似文献   

18.
A new method for the determination of nucleic acids at nanogram per mL level is proposed based on the enhanced resonance light scattering (RLS) signal resulting from the interaction of metalloporphyrins with nucleic acids. Under optimum conditions, the weak RLS signal of metalloporphyrin is enhanced by nucleic acids, and the enhanced RLS intensity is proportional to the concentration of nucleic acids. The detection limits of calf thymus DNA were 3.5ngmL–1, 2.9ngmL–1 and 1.0ngmL–1 for three metalloporphyrins, respectively. Synthetic samples were determined with satisfactory results.  相似文献   

19.
This study aims to investigate the distribution of Na, K, Rb and Cs in human brains (5 individuals, 12 brain parts, mean age: 75 years). Distribution of the trace metals between lipid fraction and brain tissue was investigated in solvent extraction experiments. Determinations were carried out by instrumental neutron activation analysis. The present results show a rather non-homogeneous distribution for Na and a relatively uniform distribution for K, Rb and Cs. The mean concentrations found are 7440µgNag–1 dry weight, 12800µgKg–1, 14µgRbg–1 and 50ngCsg–1. A highly significant positive correlation was found between Rb and Cs. Solvent extraction experiments showed that 19% of Rb and 26% of Cs of the total content is located in lipid fraction.  相似文献   

20.
The kinetics of formation and dissociation reactions of [Ru(CN)5L]3– with a series of heterocyclic ligands were studied in aqueous media. In this presence of an excess of heterocycle, the observed second order rate constants were calculated from the kobs versus [ligand] plot at =0.100m NaClO4. Activation parameters for the formation reactions (H=28±7kJmol–1 and S=140±35JK–1mol–1) are comparable for all systems, indicating a common mechanism. The kinetics of exchange of coordinated heterocycles for 1,3,5-triazine yielded a rate saturation typical of a limiting dissociative mechanism. Activation parameters of the limiting first order specific rate of dissociation reactions were H=85±7kJmol–1 and S=18±4JK–1mol–1. Equilibrium constants were calculated from the second order rates of formation and pseudo-first order rates of dissociation reaction.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号