首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
To determine sulphamethazine (SMZ) residues in edible animal foods (pig muscle, chicken muscle, egg, fish, milk and liver), a competitive direct enzyme-linked immunosorbent assay (ELISA) and a colloidal gold immunoassay were established. The limits of detection of the ELISA and the colloidal gold immunoassay were 0.02 and 0.5 μg kg−1, respectively. The specificity of the ELISA developed to the SMZ was high according to the results of cross-reactivity testing with 14 kinds of sulphonamides. To obtain a more sensitive immunoassay, buffer solution (30 mmol L−1 phosphate-buffered saline with 0.05% Tween 20, pH 8.5) was optimized through the whole test procedure. A simple and efficient extraction method for the rapid detection of SMZ residues in foods was developed, with recoveries between 74 and 117.5%. Matrix effects can be avoided by 1:10 dilution of pig muscle, chicken muscle, egg, fish, milk and liver with optimal buffer. The detection limit of SMZ was 5 μg kg−1 in liver and 2 μg kg−1 in the other five samples. For the validation of the ELISA tests, sample extracts were analysed by ELISA and high-performance liquid chromatography. The results obtained by these two methods showed a good correlation (r 2) which was greater than 0.9. The colloidal gold immunoassay presented in this assay was successfully applied to determine SMZ in pig muscle, milk and fish below or equal to the maximum residue level (20 μg kg−1).  相似文献   

2.
The development of a direct competitive enzyme-linked immunosorbent assay based on polyclonal antibodies for N-methylcarbamate insecticide metolcarb is described. Two new haptens for the metolcarb were designed and synthesized. Both haptens were conjugated with keyhole limpet hemocyanin to form the immunogens. Four rabbits were immunized with the immunogens for production of polyclonal antibodies against metolcarb. Antisera titers were tested on the homologous coating antigens using a noncompetitive indirect enzyme-linked immunosorbent assay. The high titer antisera were used to develop the direct competitive enzyme-linked immunosorbent assay for the detection of metolcarb. The antibody–antigen combination with the highest selectivity for metolcarb was further optimized and its tolerance to changes in chemical conditions (ionic strength, pH value, and organic solvent) was studied. Under optimum conditions, the sensitivity and the limit of detection were determined to be 22 μg L−1 and 1.2 μg L−1 respectively. Determination of metolcarb in fruit juices and vegetables was accomplished by simple, rapid, and efficient extraction methods. Recoveries of metolcarb from spiked samples ranged from 80.5% to 109.5%. Validation of the developed immunosorbent assay was conducted by comparison of results from high-performance liquid chromatography. The correlation between the data obtained using developed immunosorbent assay and high-performance liquid chromatography was high (R 2 = 0.9884). Therefore, the developed immunosorbent assay in this study was suitable for the rapid quantitative determination of metolcarb in agricultural products.  相似文献   

3.
Specific polyclonal antibodies against s-triazine herbicides were obtained by preparing immunogens coupling home-synthesized haptens derivatives of simazine (6-chloro-N-ethyl-N′-ethyl-1,3,5-triazine-2,4-diamine) to lysine groups of hemocyanin from keyhole limpets and bovine serum albumin carrier proteins. Three highly sensitive rabbit antisera were obtained and evaluated with a battery of six enzyme tracers derived from triazine structures in an optimized ELISA format. The antiserum As8 and the HRP-2f tracer, which yield the best assay sensitivity for simazine (detection limit 0.11 ± 0.02 μg L−1, IC50 0.88 ± 0.04 μg L−1), were applied to the development of a sensitive flow-through immunoassay for the analysis of this herbicide. The automated assay was based on a direct competitive immunosorbent assay and fluorescence detection. The optimized method presents an IC50 value of 0.35 ± 0.04 μg L−1 with a detection limit of 1.3 ± 0.9 ng L−1 and a dynamic range from 0.010 to 7.5 μg L−1 simazine. The generic nature of the antiserum was shown by good relative cross-reactivities with other triazines such as atrazine (420%) or propazine (130%) and a lower response to terbutylazine (6.4%) and desethyl-atrazine (2.2%). No cross-reactivity was obtained for nonrelated pesticides such as 2,4-dichlorophenoxyacetic acid or linuron and the assay could be applied as a screening method for triazine herbicides. The total analysis time was 30 min per determination and the immunosensor could be reused for more than 150 cycles without significant loss of activity. The immunosensor has been successfully applied to the direct analysis of simazine in surface water samples at the nanogram per liter level. The results obtained by comparative analysis of the immunosensor with a chromatographic procedure for triazines showed a close correspondence.  相似文献   

4.
The use of olaquindox (OLA) as an additive in animal feedstuffs has been prohibited in the European Union and many other countries. In this study, a highly sensitive and specific indirect competitive enzyme-linked immunosorbent assay (ELISA) for determination of OLA in animal feed samples was developed. OLA was activated by NN-carbonyldiimidazole and coupled with bovine serum albumin (BSA) and ovalbumin (OVA). It was found that the sensitivity and specificity of the two antisera were very similar, with the IC50 values of 16 ng mL−1 and 19 ng mL−1, respectively. Cross-reactivity was less than 35% for four structurally related compounds and no recognition of five other antibiotics was observed. The better antiserum I was selected for further experiments, for example testing stability, solvent effect, accuracy, and precision. The IC50 value for eight standard curves was in the range 12–18 ng mL−1 and the LOD at a signal-to-noise ratio of 3 (S/N = 3) was 0.31 ± 0.11 ng mL−1. The ELISA tolerated 5% methanol without significant influence on IC50 value. The recoveries of spiked OLA in five different animal feed types including auxin, pig complex feed, fish complex feed, broiler concentrated feed, and pig premix feed were in the range 88.3–119.0% and the intra-assay relative standard deviation (RSD) was within 4.7–33.5% (n = 3). The ELISA for unspiked feed samples was confirmed by high-performance liquid chromatography (HPLC), with a high correlation coefficient of 0.9862 (n = 5). The proposed ELISA could be a feasible quantitative/screening method for OLA analysis in feed samples with the properties of high sensitivity, specificity, simplicity of sample pretreatment, high sample throughput, and low expense. Figure Polyclonal antibody based ELISA for detection of olaquindox  相似文献   

5.
A method for analysis of diethofencarb and pyrimethanil in apple pulp and peel was developed by using dispersive liquid–liquid microextraction based on solidification of a floating organic droplet (DLLME-SFO) and high-performance liquid chromatography with diode-array detection (HPLC–DAD). Acetonitrile was used as the solvent to extract the two fungicides from apple pulp and peel, assisted by microwave irradiation. When the extraction process was finished, the target analytes in the extraction solvent were rapidly transferred from the acetonitrile extract to another extraction solvent (1-undecanol) by using DLLME-SFO. Because of the lower density of 1-undecanol than that of water, the finely dispersed droplets of 1-undecanol collected on the top of aqueous sample and solidified at low temperature. Meanwhile, the tiny particles of apple cooled and precipitated. Recovery was tested for a concentration of 8 μg kg−1. Recovery of diethofencarb and pyrimethanil from apple pulp and peel was in the range 83.5–101.3%. The repeatability of the method, expressed as relative standard deviation, varied between 4.8 and 8.3% (n = 6). Detection limits of the method for apple pulp and peel varied from 1.2–1.6 μg kg−1 for the two fungicides. Compared with conventional sample preparation, the method has the advantage of rapid speed and simple operation, and has high enrichment factors and low consumption of organic solvent.  相似文献   

6.
Fumonisins B1 (FB1) and fumonisin B2 (FB2) are the main members of a family of mycotoxins produced by Fusarium verticillioides, Fusarium proliferatum, and other fungi species of the section Liseola. The present work shows the results of comparative studies using two different procedures for the analysis of fumonisins in maize and maize-based samples. The studied analytical methods involve extraction with methanol/water, dilution with PBS, and clean-up through immunoaffinity columns. Two reagents (o-phthaldialdehyde and naphthalene-2,3-dicarboxaldehyde) were studied for formation of fluorescent derivatives. The separation and identification were carried out by high-performance liquid chromatography with fluorescence detection. The optimized method for analysis of fumonisins in maize involved extraction with methanol/water (80:20), clean-up with an immunoaffinity column, and derivatization with naphthalene-2,3-dicarboxaldehyde (NDA). The limit of detection was 20 μg kg−1 for FB1 and 15 μg kg−1 for FB2. Recoveries of FB1 and FB2 ranged from 79% to 99.6% for maize fortified at 150 μg kg−1 and 200 μg kg−1, respectively, with within-day RSDs of 3.0 and 2.7%. The proposed method was applied to 31 samples, and the presence of fumonisins was found in 14 samples at concentrations ranging from 113 to 2,026 μg kg−1. The estimated daily intake of fumonisins was 0.14 μg kg−1 body weight per day.  相似文献   

7.
A sensitive and effective method for simultaneous determination of triazolopyrimidine sulfonamide herbicide residues in soil, water, and wheat was developed using ultra-performance liquid chromatography coupled with tandem mass spectrometry. The four herbicides (pyroxsulam, flumetsulam, metosulam, and diclosulam) were cleaned up with an off-line C18 SPE cartridge and detected by tandem mass spectrometry using an electrospray ionization source in positive mode (ESI+). The determination of the target compounds was achieved in <2.0 min. The limits of detection were below 1 μg kg−1, while the limits of quantification did not exceed 3 μg kg−1 in different matrices. Quantitation was determined from calibration curves of standards containing 0.05–100 μg L−1 with r 2 > 0.997. Recovery studies were conducted at three spiked levels (0.2, 1, and 5 μg kg−1 for water; 5, 10, and 100 μg kg−1 for soil and wheat). The overall average recoveries for this method in water, soil, wheat plants, and seeds at three levels ranged from 75.4% to 106.0%, with relative standard deviations in the range of 2.1–12.5% (n = 5) for all analytes.  相似文献   

8.
A fully automated method has been developed for analysis of eighteen antibacterial compounds, including penicillins, cephalosporins and sulfonamides, in animal feed with limits of quantification in the range 0.25–5.79 μg kg−1. The method is based on pressurized liquid extraction of 3 g homogenized feed with water and online clean-up of 500 μL of the extract with C18HD cartridges. The purified sample was directly analysed by liquid chromatography–electrospray tandem mass spectrometry (SPE–LC–ESI-MS–MS). Chromatographic separation was achieved within 10 min by use of a C12 Phenomenex Hydro-RP reversed-phase analytical column and a mobile phase gradient (water + 0.1% formic acid–methanol + 0.1% formic acid). The method was validated, revealing capability for detection of concentrations as low as 0.09 μg kg−1, decision limits (CCα) and detection capabilities (CCβ) in the range 10–174 μg kg−1 and 22–182 μg kg−1, respectively, and inter-day precision ranging from 0.7 to 8.3%. Recovery, with internal standard correction, was in the range 93–134% for all analytes. The method was then applied to analysis of fifteen feed samples, nine of which contained at least one antimicrobial at concentrations between 0.006 and 1.526 mg kg−1. The performance data and results from the method were compared with those from a previous method developed by our group, using offline SPE, by analyzing the same set of samples by both methods. The online SPE approach resulted in slightly improved sensitivity, with LODs of 0.09–2.12 μg kg−1 compared with 0.12–3.94 μg kg−1 by the offline approach. In general, better recovery was achieved by use of online purification (for 72% of the analytes) and the correlation between the two methods was good. The main advantages of the new online method are rapid and automated sample pre-treatment, and reduction of sample manipulation, enabling high-throughput analysis and highly accurate results. Because of all these characteristics, the proposed method is applicable and could be deemed necessary within the field of food control and safety.  相似文献   

9.
A new molecularly imprinted polymer (MIP) has been prepared on silica beads using the radical “grafting from” polymerization method for selective extraction of minor contaminant mycotoxin of patulin (PTL). After the introduction of amino groups onto the silica surface with 3-aminopropyltriethoxysilane, azo initiator onto the silica surface was achieved by the reaction of surface amino groups with 4,4′-azobis(4-cyanopentanoic acid). The scale-up synthesis of MIP was then carried out in the presence of 6-hydroxynicotinic acid as template substitute, functional, and cross-linking monomers. The prepared sorbent was characterized using FT-IR spectroscopy, scanning electron microscopy, elemental analysis, and the adsorption–desorption selectivity, and the capacity characteristic of the polymer was investigated by a conventional batch adsorption test and Scatchard plot analysis. The results indicated that coated polymers had specific adsorption to PTL as compared with its co-occurring 5-hydroxymethyl-2-furaldehyde (hydroxymethylfurfural (HMF)), at the same bulk concentration for solution of PTL and HMF, the maximum absorbance in the solid-phase extraction (SPE) method to PTL were 93.97% or 0.654 μg/mg while to HMF they were 76.89% or 0.496 μg/mg. Scatchard analysis revealed that two classes of binding sites were formed in PTL-MIP with dissociation constants of 3.2 × 10−2 and 5.0 × 10−3 mg/mL and the affinity binding sites of 8.029 and 1.364 mg/g, respectively. The recoveries of PTL were more than 90% for the developed MISPE and around 75% for the traditional liquid–liquid extraction in spiked apple juice samples. It was concluded that the method is suitable for the scale-up synthesis of PTL-MIP grafted on silica, and the polymer can be effectively applied as SPE coupled with high-performance liquid chromatography (HPLC) for the determination of PTL in apple juice or other related products.  相似文献   

10.
A rapid fluorescence polarization (FP) immunoassay has been developed for the simultaneous determination of T-2 and HT-2 toxins in naturally contaminated wheat samples. Syntheses of four fluorescein-labelled T-2 or HT-2 toxin tracers were carried out and their binding response with seven monoclonal antibodies was evaluated. The most sensitive antibody-tracer combination was obtained by using an HT-2-specific antibody and a fluorescein-HT-2 tracer. The developed competitive FP immunoassay in solution showed high cross-reactivity for T-2 toxin (CR% = 100%) while a very low CR% for neosolaniol (0.12%) and no cross-reactivity with other mycotoxins frequently occurring in wheat. A rapid extraction procedure using 90% methanol was applied to wheat samples prior to FP immunoassay. The average recovery from spiked wheat samples (50 to 200 μg kg−1) was 96% with relative standard deviation generally lower than 8%. A limit of detection of 8 μg kg−1 for the combined toxins was determined. Comparative analyses of 45 naturally contaminated and spiked wheat samples by both the FP immunoassay and high-performance liquid chromatography/immunoaffinity clean-up showed a good correlation (r = 0.964). These results, combined with the rapidity (10 min) and simplicity of the assay, show that this method is suitable for high throughput screening as well as for quantitative determination of T-2 and HT-2 toxins in wheat.  相似文献   

11.
Neopterin is a valuable biomarker of cellular immunity associated with various pathological situations such as viral and bacterial infections, autoimmune, cardiovascular, neurodegenerative and malignant disorders. To produce specific antibodies against neopterin for a rapid multi-biomarker-based diagnosis, a novel hapten derivative was synthesized and attached to carrier proteins. The thoroughly characterized conjugates were used for immunization of BALB/c mice and rabbits. The produced monoclonal antibody reached in both direct and indirect enzyme-linked immunosorbent assay (ELISA) format LoD of 0.18 and 0.45 μg L−1, respectively, and was a superior immunoreagent for further biosensor developments with regard to assay sensitivity and material availability. The best polyclonal antibody was somewhat more sensitive in direct ELISA with LoD of 0.05 μg L−1. The optimized ELISA method was evaluated with blood samples collected from patients with renal insufficiency, patients with sepsis, patients without confirmed clinical diagnosis, and healthy volunteers. In plasma samples, neopterin concentrations ranging from 3.2 to 103 μg L−1 could be determined with the monoclonal ELISA whereas twofold lower results were obtained with the polyclonal ELISA. A satisfactory correlation of results was found between the polyclonal ELISA and IBL Neopterin ELISA kit within the concentration range 0.5–16 μg L−1 (R = 0.874; n = 40), and slightly lower correlation was found for monoclonal-based ELISA (R = 0.819; n = 40). These data show that the generated antibodies may be used as functional analytical reagents for the integration into multianalyte biochip detection systems.  相似文献   

12.
A microfluidic system incorporating chemiluminescence detection is reported as a new tool for measuring antioxidant capacity. The detection is based on a peroxyoxalate chemiluminescence (PO-CL) assay with 9,10-bis-(phenylethynyl)anthracene (BPEA) as the fluorescent probe and hydrogen peroxide as the oxidant. Antioxidant plugs injected into the hydrogen peroxide stream result in inhibition of the CL emission which can be quantified and correlated with antioxidant capacity. The PO-CL assay is performed in 800-μm-wide and 800-μm-deep microchannels on a poly(dimethylsiloxane) (PDMS) microchip. Controlled injection of the antioxidant plugs is performed through an injection valve. Of the plant-food based antioxidants tested, β-carotene was found to be the most efficient hydrogen peroxide scavenger (SA HP of 3.27 × 10−3 μmol−1 L), followed by α-tocopherol (SA HP of 2.36 × 10−3 μmol−1 L) and quercetin (SA HP of 0.31 × 10−3 μmol−1 L). Although the method is inherently simple and rapid, excellent analytical performance is afforded in terms of sensitivity, dynamic range, and precision, with RSD values typically below 1.5%. We expect our microfluidic devices to be used for in-the-field antioxidant capacity screening of plant-sourced food and pharmaceutical supplements. Figure Assembled PDMS microchip sandwiched between two glass plates with the top plate containing capillary reservoirs  相似文献   

13.
Liquid chromatography with electrospray mass spectrometry (LC–ESI-MS) instrumentation equipped with a single quadrupole mass filter has been used to determine several benzoylphenylurea insecticides (diflubenzuron, triflumuron, hexaflumuron, lufenuron and flufenoxuron). Chromatographic and MS parameters were optimised to obtain the best sensitivity and selectivity for all pesticides. Solid-phase extraction (SPE) using C18 cartridges was applied for preconcentration of pesticide trace levels in river water samples. Recoveries of benzoylphenylurea pesticides from spiked river water (0.01 and 0.025 μg L−1) were between 73 and 110% and detection limits were between 3.5 and 7.5 ng L−1. The applicability of the method to the determination of benzoylphenylurea insecticides in spiked cucumber, green beans, tomatoes and aubergines was evaluated. Samples were extracted into dichloromethane without any clean-up step. The limits of detection ranged from 1.0 to 3.2 ng mL−1 (0.68 and 2.13 μg kg−1 in the vegetable samples). Mean recoveries ranged from 79 to 114% at spiking levels of 0.01 and 0.03 mg kg−1. The method was applied to determine traces of benzoylphenylureas in both river water and vegetable samples with precision values lower than 10%. Interferences due to the matrix effect were overcome using matrix-matched standards.  相似文献   

14.
A polyclonal antibody against ochratoxin A (OTA) was produced from rabbits immunized with the OTA–BSA conjugate. A competitive direct enzyme-linked immunosorbent assay (cdELISA) and a membrane-base colloidal gold immunoassay in flow-through format were developed for the rapid detection of OTA in various food matrices. In the cdELISA, the concentration causing 50% inhibition was 0.07 ng mL−1, and the effects of different chemical conditions (ionic strength, pH value, and organic solvent) were studied. The sensitivity of the assay was higher than those previously reported. A simple, rapid, and efficient extraction method was developed and 74–110% recoveries of spiked samples were obtained. Fifty percent methanol extracts of some food samples such as barley, wheat, oat, corn, rice, and raisins could be analyzed directly by immunoassay after dilution in PBS; grape juice and beer samples could be analyzed directly after dilution with PBS; for coffee samples, a more complex method was used to remove the matrix effect effectively. Membrane-based colloidal gold immunoassays had a visual detection limit of 1.0 ng mL−1 for OTA with a detection time of less than 10 min. For the validation of the cdELISA and membrane-based colloidal gold immunoassay, samples were analyzed by high-performance liquid chromatography. The correlation between data obtained using the microwell assay and HPLC was good (R 2 = 0.984). The developed immunoassay methods are suitable for the rapid quantitative or qualitative determination of OTA in food samples.  相似文献   

15.
The worldwide contamination of winery by-products by mycotoxins may present a serious hazard to human and animal health. Mycotoxins are secondary metabolites of fungi with possible adverse effects on humans, animals, and crops that result in illnesses and economic losses. Mycotoxins are under continuous survey in Europe, but the regulatory aspects still need to be set up for winery by-products, which may be used in animal feed. The aim of this study was to implement a simple but reliable analytical methodology for ochratoxin A (OTA) quantification in grape pomaces in order to perform a survey of samples from the Douro Demarcated Region, Portugal. The method involved a unique preparation step, solvent extraction, followed by high-performance liquid chromatography (HPLC) with fluorescence (FL) detection. A comparative study was performed with two extraction solvents (ethyl acetate and methanol) as well as using extraction on an immunoaffinity column. The linearity range for OTA analysis was 0.05–23.5 μg L−1 with a detection limit of 0.05 μg L−1 and a precision (expressed by the coefficient of variation under repeatability conditions) of 0.4–14.7%. The percentage of recovery was on average 23.5 ± 3.6% (extraction with ethyl acetate) or 70.1 ± 2.5% (extraction with 70% methanol). Accounting for the recovery factor and the chromatographic detection limit, as well as the preconcentration factor, the limit of detection in grape pomaces is 0.04 μg kg−1 (ethyl acetate extraction) and 0.33 μg kg−1 (methanol extraction). Samples from 12 out of 13 sites in the Douro Demarcated Region showed OTA presence with concentrations not exceeding 0.4 μg kg−1. Both developed methods for evaluation of OTA in grape pomace are simple but efficient. Figure Extraction of ochratoxin A (OTA) from grape pomaces allows simple but efficient quantification of OTA in winery by-products by HPLC-FL  相似文献   

16.
SiO2/ZrO2/C carbon ceramic material with composition (in wt%) SiO2 = 50, ZrO2 = 20, and C = 30 was prepared by the sol–gel-processing method. A high-resolution transmission electron microscopy image showed that ZrO2 and the graphite particles are well dispersed inside the matrix. The electrical conductivity obtained for the pressed disks of the material was 18 S cm−1, indicating that C particles are also well interconnected inside the solid. An electrode modified with flavin adenine dinucleotide (FAD) prepared by immersing the solid SiO2/ZrO2/C, molded as a pressed disk, inside a FAD solution (1.0 × 10−3 mol L−1) was used to investigate the electrocatalytic reduction of bromate and iodate. The reduction of both ions occurred at a peak potential of −0.41 V vs. the saturated calomel reference electrode. The linear response range (lrr) and detection limit (dl) were: BrO3 , lrr = 4.98 × 10−5–1.23 × 10−3 mol L−1 and dl = 2.33 μmol L−1; IO3 , lrr = 4.98 × 10−5 up to 2.42 × 10−3 and dl = 1.46 μmol L−1 for iodate.  相似文献   

17.
The new analytical method using Quick, Easy, Cheap, Effective, Rugged, and Safe (QuEChERS) procedure for simultaneous determination of diacylhydrazine insecticide residues in fruits and vegetables was developed using ultra-performance liquid chromatography coupled with tandem mass spectrometry (UPLC-MS/MS). The four insecticides (tebufenozide, methoxfenozide, chromafenozide, and halofenozide) were extracted from six fruit and vegetable matrices using acetonitrile and subsequently cleaned up using primary secondary amine (PSA) or octadecylsilane (C18) as sorbent prior to UPLC-MS/MS analysis. The determination of the target compounds was achieved in less than 3.0 min using an electrospray ionization source in positive mode (ESI+) for tebufenozide, methoxfenozide, and halofenozide and in negative mode (ESI−) for chromafenozide. The limits of detection were below 0.6 μg kg−1, while the limit of quantification did not exceed 2 μg kg−1 in different matrices. The QuEChERS procedure by using two sorbents (PSA and C18) and the matrix-matched standards gave satisfactory recoveries and relative standard deviation (RSD) values in different matrices at four spiked levels (0.01, 0.05, 0.1, and 1 mg kg−1). The overall average recoveries for this method in apple, grape, cucumber, tomato, cabbage, and spinach at four levels ranged from 74.2% to 112.5% with RSDs in the range of 1.4–13.8% (n = 5) for all analytes. This study provides a theoretical basis for China to draw up maximum residue limits and analytical method for diacylhydrazine insecticide in vegetables and fruits.  相似文献   

18.
In this work, the potential of microwave-assisted alkali pretreatment in order to improve the rupture of the recalcitrant structures of the cashew able bagasse (CAB), lignocellulosic by-product in Brazil with no commercial value, is obtained from cashew apple process to juice production, was studied. First, biomass composition of CAB was determined, and the percentage of glucan and lignin was 20.54 ± 0.70% and 33.80 ± 1.30%, respectively. CAB content in terms of cellulose, hemicelluloses, and lignin, 19.21 ± 0.35%, 12.05 ± 0.37%, and 38.11 ± 0.08%, respectively, was also determined. Results showed that, after enzymatic hydrolysis, alkali concentration exerted influence on glucose formation, after pretreatment with 0.2 and 1.0 mo L−1 of NaOH (372 ± 12 and 355 ± 37 mg gglucan−1) when 2% (w/v) of cashew apple bagasse pretreated by microwave-assisted alkali pretreatment (CAB-M) was used. On the other hand, pretreatment time (15–30 min) and microwave power (600–900 W) exerted no significant effect on hydrolysis. On enzymatic hydrolysis step, improvement on solid percentage (16% w/v) and enzyme load (30 FPU gCAB-M−1) increased glucose concentration to 15 g L−1. The fermentation of the hydrolyzate by Saccharomyces cerevesiae resulted in ethanol concentration and productivity of 5.6 g L−1 and 1.41 g L−1 h−1, respectively.  相似文献   

19.
Ammonium sulphate cut protein extracts, and their pepsin hydrolysates, from the rhizomes of 15 plants in the Zingiberaceae family were screened for their in vitro angiotensin I-converting enzyme inhibitory (ACEI) activity. The protein extract from Zingiber ottensii had the highest ACEI activity (IC50 of 7.30 × 10−7 mg protein/mL) and was enriched for by SP Sepharose chromatography with five NaCl step gradients 0, 0.25, 0.50, 0.75 and 1 M NaCl collecting the corresponding five fractions. The highest ACEI activity was found in the F75 fraction, which appeared to contain a single 20.7-kDa protein, suggesting enrichment to or near to homogeneity. The ACEI activity of the F75 fraction was moderately thermostable (−20–60 °C), showed >80% activity across a broad pH range of 4–12 (optimal at pH 4–5) and appeared as a competitive inhibitor of ACE (K i of 9.1 × 10−5 mg protein/mL). For the pepsin hydrolysates, that from Zingiber cassumunar revealed the highest ACEI activity (IC50 of 0.38 ± 0.012 mg/mL), was enriched to a single active hexapeptide by RP-HPLC with a strong ACEI activity (IC50 of 0.011 ± 0.012 mg/mL) and acted as a competitive inhibitor of ACE (K i of 1.25 × 10−6 mg protein/mL).  相似文献   

20.
An indirect competitive enzyme-linked immunosorbent assay (ELISA) was developed in plate to detect three sulfonamide residues (sulfamerazine (SMR), sulfadimetoxine (SDM), and sulfadiazine (SDZ)) in gilthead sea bream (Sparus aurata) samples. Different extraction methodologies—using methanol/water 1:1 (v/v) + ethylene diamine tetraacetic acid (EDTA) 0.5% (m/v), acetonitrile, phosphate-buffered saline (PBS) 10 mmol L−1 pH 7 and acetate buffer 100 mmol L−1 pH 5—and cleanup steps, based on solid-phase extraction (C18, SCX, Si) or liquid extraction with hexane, were assayed. As optimum, a fast and simple method using acetonitrile was selected to extract the sulfonamide residues from the edible muscle of fish. Due to matrix effects, a standard addition calibration curve in fish extract is necessary for quantification purposes. Sulfonamide-free samples were spiked at different concentration levels (between 30 and 90 ng g−1, 5–15 ng mL−1 in plate) and average recoveries (n = 8), ranging from 71% to 95%, 65% to 79%, and 72% to 95%, were obtained for SMR, SDM, and SDZ, respectively. The assay detection limits for these antibiotics were lower than 100 μg kg−1 (maximum residue level established by the European Union). The accuracy was evaluated by spiking blank fish extracts at different concentrations (10–40 ng mL−1, 5–20 ng mL−1 in plate), and the relative errors ranged between ±20%. Finally, in order to confirm the utility of the developed ELISA as a screening methodology, fish samples from different supermarkets were analyzed, and results were compared with those obtained by a validated high-performance liquid chromatography (HPLC) method. The correlation between the results obtained by both ELISA and HPLC methods is satisfactory.   相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号