首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Drugs that are used as medicines and also as growth promoters in veterinary care are considered as emerging environmental contaminants and in recent years concern about their potential risk to ecosystems and human health has risen. In this paper we used a method based on liquid chromatography/electrospray tandem mass spectrometry to analyze eight coccidiostatic compounds: diclazuril, dinitrocarbanilide (the main metabolite of nicarbazin), robenidine, lasalocid, monensin, salinomycin, maduramicin and nasarin. Multiple‐stage mass spectrometry (MSn) based on the precursor ions [M+Na]+ (polyether ionophores), [M+H]+ (robenidine) and [M–H]? (diclazuril and dinitrocarbanilide) was used to study the fragmentation of these compounds. MSn data and genealogical relationships were used to propose a tentative assignment of the different fragment ions. Loss of water, decarboxylations, ketone β‐cleavages and rearrangement of cyclic ethers and amide groups were some of the fragmentations observed for these compounds. Liquid chromatography with a sub‐2 µm particle size column was coupled to tandem mass spectrometry (LC/MS/MS) allowing the separation of these compounds in less than 7 min. Method detection limits ranging from 11 to 71 ng L?1 and run‐to‐run values in terms of relative standard deviation (RSD) (up to 12%) were obtained. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

2.
The number of substances nominally listed in the prohibited list of the World Anti‐Doping Agency increases each year. Moreover, many of these substances do not have a single analytical target and must be monitored through different metabolites, artifacts, degradation products, or biomarkers. A new analytical method was developed and validated for the simultaneous analysis of peptides and organic molecules using a single sample preparation and LC‐Q‐HRMS detection. The simultaneous analysis of 450 target molecules was performed after cleanup on a mixed‐mode solid‐phase extraction cartridge, combined with untreated urine. The cleanup solvent and reconstitution solvent were the most important parameters for achieving a comprehensive sample preparation approach. A fast chromatographic run based on a multistep gradient was optimized under different flows; the detection of all substances without isomeric coelution was achieved in 11 minutes, and the chromatographic resolution was considered a critical parameter, even in high‐resolution mass spectrometry detection. The mass spectrometer was set to operate by switching between positive and negative ionization mode for FULL‐MS, all‐ion fragmentation, and FULL‐MS/MS2. The suitable parameters for the curved linear trap (c‐trap) conditions were determined and found to be the most important factors for the development of the method. Only FULL‐MS/MS2 enables the detection of steroids and peptides at concentrations lower than the minimum required performance levels set by World Anti‐Doping Agency (1 ng mL−1). The combination of the maximum injection time of the ions into the c‐trap, multiplexing experiments, and loop count under optimized conditions enabled the method to be applied to over 10 000 samples in only 2 months during the 2016 Rio Summer Olympic and Paralympic Games. The procedure details all aspects, from sample preparation to mass spectrometry detection. FULL‐MS data acquisition is performed in positive and negative ion mode simultaneously and can be applied to untargeted approaches.  相似文献   

3.
4.
The fact that the effects of herbal medicines (HMs) are brought about by their chemical constituents has created a critical demand for powerful analytical tools performing the chemical analysis to assure their efficacy, safety and quality. Liquid chromatography coupled to mass spectrometry (LC–MS) is an excellent technique to analyze multi-components in complex herbal matrices. Due to its inherent characteristics of accurate mass measurements and high resolution, time-of-flight (TOF) MS is well-suited to this field, especially for qualitative applications. The purpose of this article is to provide an overview on the potential of TOF, including the hybrid quadrupole- and ion trap-TOF (QTOF and IT-TOF), hyphenated to LC for chemical analysis in HMs or HM-treated biological samples. The peculiarities of LC–(Q/IT)TOF-MS for the analysis of HMs are discussed first, including applied stationary phase, mobile-phase selection, accurate mass measurements, fragmentation and selectivity. The final section is devoted to describing the applicability of LC–(Q/IT)TOF-MS to routine analysis of multi-components, including target and non-target (unknown) compounds, in herbal samples, emphasizing both the advantages and limitations of this approach for qualitative and quantitative purposes. The potential and future trends of fast high-performance liquid chromatography (HPLC) (e.g. rapid resolution LC and ultra-performance LC) coupled to (Q)TOF-MS for chemical analysis of HMs are highlighted.  相似文献   

5.
6.
This paper describes the development of a high performance liquid chromatography/tandem mass spectrometric (MS/MS) procedure for the specific qualitative and quantitative analysis of lipid aldehydes in biological matrices. A derivatisation method, which results in molecules that exhibit a common product ion on MS/MS, permits informative precursor ion scans, at high sensitivity. This has been applied to the examination of plasma in order to examine the production of aldehydes consequent on in vitro lipid oxidation. Quantitative analysis of target molecules using multiple reaction monitoring has been developed to permit quantitation in the same matrices.  相似文献   

7.
8.
A rapid multiresidue method for the analysis of more than 40 herbicides (such as simazine, terbuthylazine and diuron) in waters has been developed and validated by ultra-performance liquid chromatography coupled to tandem mass spectrometry (UPLC/MS/MS). Prior to chromatographic determination, the samples were extracted using a solid-phase extraction procedure. The analysis was performed on an Acquity UPLC BEH C(18) column using a gradient elution profile and a mobile phase consisting of methanol and an aqueous solution of formic acid (0.01%). Other chromatographic and MS/MS parameters were optimised in order to improve selectivity and sensitivity of the analytes. The analytes were detected using electrospray ionisation (ESI)-MS/MS in positive ion mode with multiple reaction monitoring (MRM), optimising parameters such as voltage cone, capillary voltage, source and desolvation temperature, and desolvation and cone gas flow. The optimised method provides a rapid separation (less than 10 min) of the selected herbicides in the assayed matrices, and it was validated by the analysis of spiked blank matrix samples. Good linearity was obtained and the repeatability of the method was less than 20% for the lowest calibration point. The limits of detection ranged from 0.002 to 0.02 microg/L, and the limits of quantification from 0.005 to 0.05 microg/L, which were below the values specified by the European Union. Finally, the method was successfully applied to real environmental samples from Andalusia (southern Spain). Terbuthylazine, simazine, atrazine desisopropyl and desethyl terbuthylazine were the herbicides most frequently found in water samples.  相似文献   

9.
A rapid and reliable method was established for simultaneous determination of main triterpenoids in Ganoderma lucidum spores using ultra‐high‐performance liquid chromatography coupled with triple quadrupole mass spectrometry (UPLC‐TQ‐MS). The established method was validated in terms of linearity, sensitivity, precision, accuracy and stability, and was successfully applied to determine the contents of 10 main triterpenoids in different batches of G. lucidum spores. The analysis results showed that moderate levels of triterpenoids were found in G. lucidum spores. In addition, a MS full scan with a daughter ion scan experiment was performed to identify the potential derivatives of triterpenoids present in G. lucidum spores. As a result, a total of 22 triterpenoids from different G. lucidum spores were unequivocally or tentatively identified via comparisons with authentic standards and literatures. This method provides both qualitative and quantitative results without the need for repetitive UPLC‐MS analyses, thereby increasing efficiency and productivity, making it suitable for high‐throughput applications. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

10.
11.
12.
13.
The fragmentation pathways of three explosive compounds with similar structures, hexanitrostilbene (HNS), cyclotrimethylene trinitramine (RDX), and 2,4,6-trinitrotoluene (TNT), have been investigated by multiple mass spectrometry (MSn, n = 1, 2, 3) with electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) sources. The electron capture mechanism for these compounds in negative ion APCI and ESI mode differs from the usual negative ion mechanism, deprotonation or addition of other species. This was shown for HNS and TNT, which both gave a [M]- anion but not a [M-H]- ion in APCI, and the [M]- anion of HNS was observed in ESI. The quantitative analysis of HNS was performed by liquid chromatography (LC)/ESI-MS, and the results obtained by the internal standard (ISTD) method were compared with those from the external standard (ESTD) method, demonstrating that both quantitation approaches are useful, with good sensitivity, reproducibility and linearity, and ESTD is preferable in routine applications.  相似文献   

14.
This paper presents a method for the determination of acebutolol, betaxolol, bisoprolol, metoprolol, nebivolol and sotalol in human serum by liquid–liquid extraction and ultra‐high‐performance liquid chromatography coupled with ultra‐high‐resolution TOF mass spectrometry. After liquid–liquid extraction, beta blockers were separated on a reverse‐phase analytical column (Acclaim RS 120; 100 × 2.1 mm, 2.2 μm). The total run time was 6 min for each sample. Linearity, limit of detection, limit of quantification, matrix effects, specificity, precision, accuracy, recovery and sample stability were evaluated. The method was successfully applied to the therapeutic drug monitoring of 108 patients with hypertension. This method was also used for determination of beta blockers in 33 intoxicated patients.  相似文献   

15.
16.
On-line atmospheric pressure chemical ionization (APCI) and electrospray ionization (ESI) liquid chromatography/mass spectrometry (LC/MS) were evaluated for the analysis of a variety of steroids. Steroids were classified into three major groups based on the spectra and the sensitivities observed: (I) those containing a 3-one, 4-ene functional group, (II) those containing at least one ketone group without conjugation, and (III) those containing hydroxy group(s) only. In the APCI mode, the best sensitivity and the lowest detection limit for all three groups were obtained by using a mobile phase consisting of methanol and 1%–2% acetic acid in water. The APCI spectra were characterized by MH+, MH+-H2O, MH+-2H2O, etc., with the degree of H2O loss being compound dependent: group I steroids produced stable MH+ and group III steroids showed extensive water loss. In the electrospray mode the best sensitivity and the lowest detection limit for the first two groups were obtained when pure methanol and water were used as the mobile phase. This condition produced abundant stable MNa+ due to ubiquitous sodium. Detection limits in the 5–15 pg range can be easily achieved using ESI LC/MS. Addition of ammonium acetate or use of acetonitrile in the mobile phase, common in the LC/MS analysis of steroids, decreased the sensitivity for the group I and II steroids and thus should be avoided. For group III steroids, the detection limit can be improved by the addition of acetic acid to the mobile phase.  相似文献   

17.
18.
19.
Glycosylation is one of the most common posttranslational modifications (PTMs) of proteins, the characterization of which is commonly achieved through proteomic protocol, involving trypsin digestion followed by liquid chromatography/tandem mass spectrometry (LC/MS/MS). However, it is often not possible to characterize all glycopeptides in a complex sample because of the high complexity of glycoproteomic samples, and the relative lower abundances of glycopeptides in comparison to the unmodified peptides. We present here a targeted MS/MS analysis approach, which utilizes a previously developed computational tool, GlyPID, to guide multiple experiments, thus permitting a complete characterization of all N‐glycosylation sites of glycoproteins present in a complex sample. We have tested our approach using model glycoproteins analyzed by high‐resolution LTQ‐FT MS. The results demonstrate a potential use of our method for a high‐throughput characterization of complex mixtures of glycosylated proteins. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

20.
Hydrophilic interaction chromatography (HILIC) liquid chromatography/mass spectrometry (LC/MS) is appropriate for all native and reductively aminated glycan classes. HILIC carries the advantage that retention times vary predictably according to oligosaccharide composition. Chromatographic conditions are compatible with sensitive and reproducible glycomics analysis of large numbers of samples. The data are extremely useful for quantitative profiling of glycans expressed in biological tissues. With these analytical developments, the rate-limiting factor for widespread use of HILIC LC/MS in glycomics is the analysis of the data. In order to eliminate this problem, a Java-based open source software tool, Manatee, was developed for targeted analysis of HILIC LC/MS glycan datasets. This tool uses user-defined lists of compositions that specify the glycan chemical space in a given biological context. The program accepts high-resolution LC/MS data using the public mzXML format and is capable of processing a large data file in a few minutes on a standard desktop computer. The program allows mining of HILIC LC/MS data with an output compatible with multivariate statistical analysis. It is envisaged that the Manatee tool will complement more computationally intensive LC/MS processing tools based on deconvolution and deisotoping of LC/MS data. The capabilities of the tool were demonstrated using a set of HILIC LC/MS data on organ-specific heparan sulfates.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号