首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Suzuki A  Lim LW  Hiroi T  Takeuchi T 《Talanta》2006,70(1):190-193
Monolithic silica capillary columns dynamically modified with quaternary ammonium ions were evaluated for the determination of bromide in seawater samples. A quaternary ammonium ion such as cetyltrimethylammonium ion was dynamically introduced onto monolithic silica surfaces. The first layer of the modifier was introduced by electrostatic interaction, whereas the second layer was introduced by hydrophobic interaction. The latter layer worked as the anion-exchange sites. The modified monolithic silica capillary columns could be used for rapid separation of inorganic anions. Separation of authentic mixture of five anions was achieved within a few minutes. The addition of small amount of the modifier in the eluent improved the repeatability of the retention time. Seawater samples could be directly injected onto the prepared capillary columns, and bromide could be determined to be 63 mg/L.  相似文献   

2.
A rapid and simple capillary electrophoretic method was developed for the direct determination of bromide ion in seawater. We have found an effective method, based on the use of polyethyleneimine-coated capillaries and the addition of sodium chloride to the background electrolyte. The use of coated capillaries with a cationic polymer changes the direction of the electroosmotic flow in the capillary, which favors the migration speed of the bromide ion and enables the use of low salt concentrations in the separation electrolyte. Bromide ion in seawater can be determined within 2 min using this system and 20 mmol L-1 NaCl-containing separation electrolyte. The detection limit for the bromide ion was 0.45 g ml-1. The method was applied to the determination of bromide ion in seawater samples collected from the Bosphorus and the Black Sea. Bromide contents in samples from 0 to 72 m depths varied between 33.2 and 72.8 mg L-1 with a mean 3.0% RSD.  相似文献   

3.
An ion chromatographic method for rapid and direct determination of iodide in seawater samples is reported. Separation was achieved using a laboratory-made C30 packed column (100 mm × 0.32 mm i.d.) modified with polyoxyethylene oleyl ether, with an aqueous solution of 300 mM sodium chloride as eluent and using UV detection at 220 nm. Samples containing iodate, nitrate, iodide and thiocyanate were eluted within 8 min, and the relative standard deviations of the retention time, peak area and peak height were all smaller than 4.19% for all of the analyte anions. Effects of eluent composition on retention behavior of inorganic anions have been investigated. Both cation and anion of the eluent affected the retention time of analytes. When inorganic eluents, such as ammonium chloride, ammonium sulfate, lithium chloride, sodium chloride, sodium sulfate, magnesium chloride and magnesium sulfate were used, the retention time of analytes increased with increasing eluent concentration. The limit of detection of iodide was 19 μg l−1 (S/N = 3), while the limit of quantitation was 66 μg l−1 (S/N = 10). The present method was successfully applied to the rapid and direct determination of iodide in seawater samples.  相似文献   

4.
Conventional silica columns dynamically modified with cetyltrimethylammonium ions were evaluated for the determination of UV-absorbing bromide, nitrate, and nitrite in seawater samples. Cetyltrimethylammonium, which is a quaternary ammonium ion, was dynamically introduced onto silica surfaces. The first layer of the modifier was introduced by electrostatic interaction, whereas the second layer was introduced by hydrophobic interaction. The latter layer worked as the anion-exchange sites. The modified conventional silica columns could be used for separation of inorganic anions. Separation of authentic mixture of five anions was achieved within 17 min. The addition of 0.1 mM cetyltrimethylammonium ion to the eluent improved the repeatability of the retention time. Seawater samples could be directly injected onto the prepared conventional silica columns, and bromide, nitrate, and nitrite levels were determined to be 69, 0.13, and 0.016 ppm, respectively.  相似文献   

5.
An ion-chromatographic (IC) system with high selectivity for separation of nitrite is described. It is analogous to the EIC (electrostatic IC) previously reported and was established using 3-(N,N-dimethylstearylammonio)propanesulfonate (C23H49NO3S, a sulfobetaine type of zwitterionic surfactants) as the stationary phase and dilute aqueous HCl solutions as the mobile phase. Five inorganic anions, sulfate, chloride, bromide, nitrate, and nitrite were chosen as the model analytes and were analyzed using this EIC system. Sulfate was always eluted first, followed by chloride, bromide and nitrate. Nitrite, however, could be eluted either before or after nitrate, depending on the concentration of HCl in the eluent. An elution order nitrate< nitrite was always obtained simply by using >3 mmol L(-1) HCl as the eluent. For nitrite the detection limit was better than 2.1 x 10(-7) mol L(-1) (100 microL sample injection volume, S/N=3, UV at 210 nm). Bromide and nitrate could also be separated under these HPLC conditions. The detection limit for bromide was 7.2 x 10(-8) mol L(-1) and for nitrate 6.5 x 10(-8) mol L(-1). Both nitrite and nitrate in real seawater samples were successfully determined with direct sample injection using this EIC system.  相似文献   

6.
We describe capillary zone electrophoresis (CZE) for the simultaneous determination of bromide, nitrite and nitrate ions in seawater. Artificial seawater was adopted as the carrier solution to eliminate the interference of high concentrations of salts in seawater. The artificial seawater was free from bromide ion to enable the determination of bromide ion in a sample solution. For the purpose of reversing the electroosmotic flow (EOF), 3 mM cetyltrimethylammonium chloride (CTAC) was added to the carrier solution. A 100 microm ID (inside diameter) capillary was used to extend the optical path length. The limits of detection (LODs) for bromide, nitrite, and nitrate ions were 0.46, 0.072, and 0.042 mg/L (as nitrogen), respectively. The LODs were obtained at a signal to noise ratio (S/N) of 3. The values of the relative standard deviation (RSD) of peak area for these ions were 1.1, 1.5, and 0.97%. The RSDs of migration time for these ions were 0.61, 0.69, and 0.66%. Artificial seawater samples containing various concentrations of bromide, nitrite, and nitrate ions were analyzed by the method. The error was less than +/-12% even if the concentration ratio of bromide ion to nitrite or nitrate ion was 20-240. The proposed method was applied to the determination of bromide, nitrite, and nitrate ions in seawater samples taken from the surface and the seabed. These ions in other environmental waters such as river water and rainwater samples were also determined by ion chromatography (IC) as well as this method.  相似文献   

7.
An ion chromatography method for rapid and direct determination of iodide in seawater and edible salt is reported. Separation was achieved using a laboratory-made C30 packed column (100 mm x 0.32 mm i.d.) modified with poly(ethylene glycol) (PEG). Effects of eluent composition on retention behavior of inorganic anions have been investigated. Both cation and anion of the eluent affected the retention of analyte anions. The retention time of anions increased with increasing eluent concentration when lithium chloride, sodium chloride, potassium chloride, sodium sulfate, magnesium sulfate were used as the eluent, while it decreased with increasing eluent concentration when ammonium sulfate was used as the eluent. The detection limit for iodide obtained by injecting 0.2 microl of sample was 9 microg/l (S/N = 3). The present method was successfully applied to the rapid and direct determination of iodide in seawater and edible salt samples. Partition may be involved in the present separation mode.  相似文献   

8.
A new ion chromatographic (IC) system has been established by using micelles of 3-(N,N-dimethylmyristylammonio)propanesulfonate (Zwittergent 3-14) loaded onto a reversed-phase packed column as the separation column with an electronic rotary switching valve packed-bed suppressor for conductometric detection of inorganic anions. An aqueous H3BO3-Na2B4O7 solution has been demonstrated to be the most desirable eluent for this IC system. The relationship between retention time and the concentration of the borate eluent was determined for a series of model anionic analytes and this relationship was found to be opposite to that exhibited in a conventional anion-exchange IC system. The rapid elution and complete separation of monovalent inorganic anions were obtained by initially using a high-concentration borate solution as the eluent for a short-period, and then switching to a lower-concentration borate eluent to complete the separation. Detection limits for nitrite, bromide, nitrate, and chlorate were 0.85, 0.88, 0.95 and 4.8 microM, respectively, when a 7.0 mM Na2B4O7 eluent was used. Moreover, the ability to directly detect these monovalent anions in samples containing high concentrations of sulfate and/or chloride ions provided a major advantage of this approach.  相似文献   

9.
An electrostatic ion chromatographic (IC) method for rapid and direct determination of iodide in seawater is reported. Separation was achieved using a reversed-phase ODS packed column (250x4.6 mm I.D.) modified by coating with Zwittergent-3-14 micelles, with an eluent comprising an aqueous solution containing 0.2 mM NaClO4 and 0.3 mM Zwittergent-3-14 and using UV detection at 210 nm. Samples prepared by dissolving NaIO3, NaNO2, NaBr, NaBrO3, NaNO3, NaI, and NaSCN in artificial or real seawaters were analyzed using this IC system. Nitrite, iodate, bromide, bromate, and nitrate showed very little or no retention, while iodide and thiocyanate were well separated, being eluted within 6 and 16 min, respectively. The detection limit for iodide obtained by injecting 400 microL of sample was 0.011 microM (S/N = 3), and the precision values obtained by analyzing samples containing 0.1 or 0.3 microM iodide in real seawater samples were 2.3% RSD and 1.2% RSD, respectively. Direct determination of iodide in real seawater samples was possible using this proposed IC system.  相似文献   

10.
Bromide and iodide ions were determined simultaneously by capillary isotachophoresis using an aqueous electrolyte system; the separation principle was based on the ion-pairing equilibria between tetradecyldimethylbenzylammonium ion and these anions in the leading electrolyte. The interaction between iodide ion and tetradecyldimethylbenzylammonium ion was stronger than that for bromide ion. Thus complete separation of bromide and iodide ions could be obtained by using a leading electrolyte containing 1.5 mM tetradecyldimethylbenzylammonium ion. The pH of the leading electrolyte was adjusted to 5.0. The relative standard deviations of the zone length for bromide and iodide ions were 1.1 and 1.2%, respectively, when mixture of 3.0 mM of these ions was analysed. A 150-μl volume could be injected for the simultaneous determination of low concentrations of bromide and iodide ions.  相似文献   

11.
Although anions are usually determined by suppressed ion chromatography (IC), carbonate and bicarbonate ions can not be determined, because a mixed solution of sodium carbonate and sodium hydrogencarbonate is used as the eluent. This paper describes an IC method for the determination of carbonate ion and common anions using an IonPac AG17/AS17 column, an EG 40 eluent generator and a conductivity detector. The proposed IC method could determine carbonate ion and anions within 6 min. The relative standard deviations (n = 5) for chloride (0.4 mg L(-1)), nitrite (0.8 mg L(-1)), carbonate (100 mg L(-1)), nitrate (1.0 mg L(-1)) and sulfate (2.0 mg L(-1)) ions were 5.1%, 1.1%, 4.2%, 5.1% and 1.1%, respectively. In addition, the absorbing solution of carbon dioxide was examined, and 2-amino-2-methyl-1-propanol was found to be a good absorbing solution. The proposed IC method was applied to the determination of carbon dioxide and acid components in flue gas and automobile exhaust gas.  相似文献   

12.
The hydrogen bond resonance of a sodium chloride (NaCl) ion pair trapped in aqueous ice has been observed by transmission terahertz time-domain spectroscopy. The absorption peak of a sodium chloride ion pair in ice is 1.65 THz at 83 K. By investigating the interaction of the cation and anion with other chemical compounds, we deduce that the absorption peak originates from the hydrogen bond resonance of sodium chloride and water molecules. The charge redistribution that occurs when other ion pairs are added to aqueous salt solution changes the absorption spectrum. Furthermore, the results also indicate that simple molecules such as sodium halides have fingerprints in the terahertz region when the ions are trapped in ice. NaCl ion pairs in seawater and in Ringer's solution were examined.  相似文献   

13.
Dibutyl-and monobutylphosphoric acid in acidic toluene medium were determined by ion chromatography. The procedure involved stripping with dilute sodium hydroxide solution and used carbon tetrachloride as diluent, then detection with a conductivity meter. The effect of flow rate, eluent strength and stripping solution, the effect of chloride and nitrate ion on DBP, the effect on DBP in sodium hydroxide solution, and the effect of organic aliphatic acids were discussed. The detection limits of 0.19 ppm and 0.14 ppm were found for DBP and MBP, respectively.  相似文献   

14.
Ion-exchange chromatography using a high-capacity anion exchanger with UV detection was applied to the determination of nitrate in seawater. Major ions in seawater samples did not affect the peak shape and the retention time of the nitrate when an alkaline metal cation-chloride solution was used as an eluent at high concentrations (0.5-2 mol/l). At a wavelength of 220 nm, the peak of bromide was very small because of low absorption, while its separation from the nitrate peak was good at high concentrations. Among the eluents tested, lithium chloride gave the best separation of nitrate from bromide. It was estimated that the lithium ion had the least potential for ion-pair formation with nitrate, and its retention time was prolonged compared with the retention times when using other cations; with bromide and nitrite, such an effect was not observed. The results of shipboard seawater nitrate determination by our method in the South Pacific Ocean and Antarctic Sea showed good agreement with those by the conventional photometric method using continuous flow.  相似文献   

15.
A method was developed for determination of inorganic anions, including nitrite (NO 2 ? ), nitrate (NO 3 ? ), bromide (Br?), and iodide (I?), in seawater by ion chromatography (IC). The IC system used two dilauryldimethylammonium bromide (DDAB)-coated monolithic ODS columns (50?×?4.6?mm i.d. and 100?×?4.6?mm i.d.) connected in series for separation of the ions. Aqueous NaCl (0.5?mol/L; flow rate, 3?mL/min) containing 5?mmol/L phosphate buffer (pH 5) was used as the eluent, and detection was with a UV detector at 225?nm. The monolithic ODS columns were coated and equilibrated with a 1-mmol/L DDAB solution (in H2O/methanol, 90:10 v/v). The hydrophilic ions (NO 2 ? , NO 3 ? , and Br?) were separated within 3?min and the retention time of I? was 16?min. No interferences from matrix ions, such as chloride and sulfate ions, were observed in 35?‰ artificial seawater. The detection limits were 0.6?μg/L for NO 2 ? , 1.1?μg/L for NO 3 ? , 70?μg/L for Br?, and 1.6?μg/L for I? with a 200-μL sample injection. The performance of the coated columns was maintained without addition of DDAB in the eluent. The IC system was successfully applied to real seawater samples with recovery rates of 94–108?% for all ions.
Figure
The hydrophilic ions (NO 2 ? , NO 3 ? , and Br?) and I? in seawater was determined by a single run using the IC system consisting of two dilauryldimethylammonium bromide (DDAB)-coated monolithic ODS columns (50?×?4.6?mm i.d. and 100?×?4.6?mm i.d.) connected in series, NaCl (0.5?mol/L; flow rate, 3?mL/min) containing 5?mmol/L phosphate buffer (pH 5) as the eluent, and a UV detector (225?nm). No interferences from matrix ions, such as chloride and sulfate ions, were observed in 35?‰ artificial and real seawaters.  相似文献   

16.
Halide ions could be visualized via fluorescence quenching in microcolumn ion chromatography. The fluorescence of quinine sulfate, which was contained in an acidic eluent, was quenched by halide ions. The observed fluorescence quenching values increased in this order: iodide, bromide, and chloride. The present detection system was relatively sensitive to halide ions except for fluoride: other anions gave smaller signals than halide ions. The present detection system provided quantitative information, so it could be applied to the determination of chloride in water samples.  相似文献   

17.
In anion-exchange chromatography using a high-concentration eluent and high-capacity ion-exchange resin, the effect of the countercation contained in the eluent was investigated. Cadmium(II) and zinc(II) ions were examined as additives in an aqueous potassium chloride eluent. The addition of these cations resulted in a reversed elution order of bromide and nitrate, as compared with conventional anion-exchange chromatography. The separation factor for these two anions increased as the cadmium concentration in the eluent was increased. Zinc(II) ion was also effective, but a relatively high concentration was necessary.  相似文献   

18.
Yang B  Diao X 《色谱》2012,30(4):333-339
离子色谱是目前分析离子型样品的成熟技术,其水相工作介质的特点相对于液相色谱更适合于生物样品的分析。毛细管离子色谱(CIC)由于其节省样品的特点在生物分析方面的优势更为明显。CIC大体上可分为开管型、填充柱型和整体柱型3种类型。本文以填充型CIC几大关键部件技术发展为主线,综述了近年来CIC的研究进展。  相似文献   

19.
A new method for the determination of chloride ion is based on the formation of phenylmercury(II) chloride, its extraction into chloroform and reaction with sodium diethyldithiocarbamate to form phenylmercury(II) diethyldithiocarbamate. This complex has spectral maxima at 257 and 297 nm. either of which can he used for quantitative purposes. The molar absorptivities are 21.3·103 and 6.5·103 respectively. referred to the chloride ion. The method is especially suitable for the determination of trace amounts of chloride in aqueous solution and has been applied to samples of drinking water. Amounts of chloride in the range 0.04 0.32 p.p.m. can be determined in 250-ml aqueous samples with an average relative mean error of 12%. The method can be used also for bromide and iodide, and for organomercury(11) compounds. Interferences are minimal and the method compares favourably with the standard mercury(II) thiocyanate procedure.  相似文献   

20.
The Fusarium mycotoxin moniliformin (hydroxycyclobutenedione) has been determined in maize using a novel method with a recovery of 70-80% at 400-1600 micrograms/kg and 60% at the detection limit of 100 micrograms/kg. The method requires extraction of the toxin into aqueous tetra-n-butylammonium hydroxide and removal of cations from this solution by ion-exchange chromatography. Following clean-up by partitioning against dichloromethane, further quaternary ammonium reagent was added to the aqueous phase which was absorbed onto a hydrophilic matrix and the tetra-n-butylammonium moniliformate ion pair extracted into dichloromethane. After evaporation of the organic eluent, the residue was dissolved in aqueous sodium chloride and moniliformin quantitated by ion-pair high-performance liquid chromatography with UV detection. A batch of five samples may be analysed in 5-6 h including the chromatographic determination.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号