首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A new continuous-flow automated enzymatic method suitable for the direct determination of creatinine in physiological samples is described. The proposed system utilizes an on-line gas predialysis unit in conjuction with a flow-through enzyme reactor coil and a potentiometric ammonia detector. The enzyme reactor contains immobilized creatinine iminohydrolase (EC 3.5.4.21) which converts creatinine to ammonia and N-methylhydantoin. Ammonia liberated from this reaction is detected downstream with the membrane electrode-based detector. The novel gas predialysis unit effectively removes >99.8% of endogenous ammonia (up to 1 mM) present in the sample. Thus, final peak potentials recorded by the electrode detector are directly proportional to the logarithm of creatinine concentrations present. The method is shown to be precise (<3%), selective, and capable of accurately determining creatinine in serum and urine samples containing abnormally high endogenous ammonia levels. Determinations of creatinine in serum samples (n = 30) using this new method correlate well with an existing Technicon AutoAnalyzer colorimetric method (r = 0.996).  相似文献   

2.
The abatement of ammonia in standard solutions, and in human blood and urine samples is achieved by adding suitable amounts of NADPH and α-ketoglutarate to the sample and passing it through a 2-m nylon tube with glutamate dehydrogenase immobilized on the inner wall. The procedure provides removal of 98% of the ammonia (1–5 × 10?4 M) in the original sample in 50 s. The abatement of ammonia permits the use of an ammonia probe coupled with an immobilized degradative enzyme for the determination of creatinine. Creatinine was determined in clinical blood and urine samples by first removing the ammonia from the sample and then cleaving the creatinine to N-methylhydantoin and ammonia with immobilized creatininase. Only 200 μl of sample is needed and the entire process is conducted in a single flow stream.  相似文献   

3.
The classical Jaffé reaction for the determination of creatinine in urine samples is tested. A comparative study of the main analytical characteristics focussed to minimize the bias error and improve the precision, for the batchwise and flow injection (FI) methods is realized. Also, the effect of the albumin concentration in the determination of creatinine has been studied. Different analytical signals were studied. Absorbance increments at different times permit to estimate the creatinine concentration free from bias error in urine by the batchwise method using the calibration graph obtained with creatinine standards and no measurement of the blank solution is needed. The lineal interval was 0.92-50 mg l(-1) and seven samples can be processed per hour by an operator. No previous treatment of the urine sample is necessary. The FI method provides also good results. The lineal interval was 30-100 mg l(-1) and the sample rate was around 20 samples per hour. If increased albumin levels are detected in the urine, standard addition method or the calibration graphs with standards in presence of albumin are needed in order to obtain accurate results when FI method is employed. The obtained accuracy of the both methods allows its application as diagnostic tool to establish the urinary creatinine levels.  相似文献   

4.
The classical Jaffé reaction for the determination of creatinine in urine samples is tested. A comparative study of the main analytical characteristics focussed to minimize the bias error and improve the precision, for the batchwise and flow injection (FI) methods is realized. Also, the effect of the albumin concentration in the determination of creatinine has been studied. Different analytical signals were studied. Absorbance increments at different times permit to estimate the creatinine concentration free from bias error in urine by the batchwise method using the calibration graph obtained with creatinine standards and no measurement of the blank solution is needed. The lineal interval was 0.92–50 mg l−1 and seven samples can be processed per hour by an operator. No previous treatment of the urine sample is necessary. The FI method provides also good results. The lineal interval was 30–100 mg l−1 and the sample rate was around 20 samples per hour. If increased albumin levels are detected in the urine, standard addition method or the calibration graphs with standards in presence of albumin are needed in order to obtain accurate results when FI method is employed. The obtained accuracy of the both methods allows its application as diagnostic tool to establish the urinary creatinine levels.  相似文献   

5.
Creatinine is an important biomarker for renal function diagnosis and normalizing variations in urinary drug/metabolites concentration. Quantification of creatinine in biological fluids such as urine and plasma is important for clinical diagnosis as well as in biomonitoring programs and urinary metabolomics/metabonomics research. Current methods for creatinine determination either are nonselective or involve the use of expensive mass spectrometers. In this paper, a novel reversed-phase high-performance liquid chromatographic (HPLC) method for the determination of creatinine of high hydrophilicity by pre-column derivatization with ethyl chloroformate is presented. N-Ethyloxycarbonylation of creatinine significantly enhanced the hydrophobicity of creatinine, facilitating its chromatographic retention as well as quantification by HPLC. Factors governing the derivatization reaction were studied and optimized. The developed method was validated and applied for the determination of creatinine in rat urine samples. Comparative studies with isotope-dilution mass spectrometric method revealed that the two methods do not yield systematic differences in creatinine concentrations, indicating the HPLC method is suitable for the determination of creatinine in urine samples.
Figure
?  相似文献   

6.
CE with capacitively coupled contactless conductivity detection (C(4)D) was used to determine waste products of the nitrogen metabolism (ammonia and creatinine) and of biogenic inorganic cations in samples of human urine. The CE separation was performed in two BGEs, consisting of 2 M acetic acid + 1.5 mM crown ether 18-crown-6 (BGE I) and 2 M acetic acid + 2% w/v PEG (BGE II). Only BGE II permitted complete separation of all the analytes in a model sample and in real urine samples. The LOD values for the optimized procedure ranged from 0.8 microM for Ca(2+) and Mg(2+) to 2.9 microM for NH(4)(+) (in terms of mass concentration units, from 7 microg/L for Li(+) to 102 microg/L for creatinine). These values are adequate for determination of NH(4)(+), creatinine, Na(+), K(+), Ca(2+) and Mg(2+) in real urine samples.  相似文献   

7.
Abstract

Creatinine determination in urine and plasma affords an index of the renal function. Reversed-phase high pressure liquid chromatography was used for the separation and quantitation of creatinine in normal and arsenic exposed human urine samples. Acetonitrile/water (1:1) was the mobile phase. The method was compared with the Jaffé alkaline picrate reaction. Results show that the HPLC procedure has high reproducibility and samples are stable at the storage conditions. Plasma samples required depro-teinization and extraction with CH3CN prior to HPLC analysis, while urine samples required only centrifugation.  相似文献   

8.
Zuo Y  Yang Y  Zhu Z  He W  Aydin Z 《Talanta》2011,83(5):53-1710
Uric acid is the end-product of purine metabolism and a major antioxidant in humans. The concentrations of uric acid in plasma and urine are associated with various diseases and routinely measured in clinical and biomedical laboratories using enzymatic conversion and colorimetric measurement. In this study a hydrophilic interaction chromatographic (HILIC) method was developed for simultaneous determination of uric acid and creatinine, a biomarker of urine dilution and renal function, in human urine. Urine samples were pretreated by dilution, protein precipitation, centrifugation and filtration. Uric acid and creatinine were separated from other components in urine samples and quantified using HILIC chromatography. A linear relationship between the ratio of the peak area of the standards to that of the internal standard and the concentration of the standards was obtained for both uric acid and creatinine with the square of correlation coefficients >0.999 for both analytes. The detection limits were 0.04 μg/mL for creatinine and 0.06 μg/mL for uric acid. The described HILIC method has proved to be simple, accurate, robust and reliable.  相似文献   

9.
A new spectrofluorimetric method for the simultaneous determination of canrenone and spironolactone in urine is proposed. The method is based on the different rates at which the two analytes react with hot sulfuric acid to form a trienone. The kinetic spectrofluorimetric data are processed by partial least-squares regression. The effects of sulfuric acid concentration and temperature on the system under study were also evaluated and the optimum values for carring out the reaction were 50% and 50 degrees C, respectively. The method was checked by analyzing urine samples that they contained both diuretics. The accuracy and the precision of the method were tested. The relative standard errors in the quantification of each analyte in all tested samples were 3.69 and 3.59%. The proposed method was validated by comparison with a high performance liquid chromatographic method for urine samples.  相似文献   

10.
周继红  袁倚盛  许丹科 《色谱》1998,16(2):176-177
报道了采用高效毛细管区带电泳技术直接将人尿液注入毛细管进行尿液中肌酐、尿酸及伪尿核苷含量测定的新方法。试验表明,以磷酸盐(pH6.1)作缓冲液,对人体尿液中肌酐、尿酸及伪尿核苷进行直接分析具有较高的灵敏度和较好的重复性。  相似文献   

11.
《Analytical letters》2012,45(10):1779-1784
Abstract

Creatinine in urine concentrations are routinely measured at Aldermaston by an autoanalyser, using the Jaffe reaction, as an index of urinary excretion rates. These values are used in calculations to estimate the body content of radionuclides from their urinary excretion rates.

Unfortunately, creatinine in urine concentrations gradually decrease with sample age due to pseudo first order hydrolysis of creatinine to give creatine in the presence of ammonia. This reaction may be arrested or reversed by mineral acid.

After storage at ambient temperatures for several weeks the creatinine in urine concentration falls by around 20%, so it is good practice to analyse samples soon after provision.

The activation energy for the hydrolysis of creatinine in urine is around 60 KJ/mol over the range 20–70 °C. Hence, raising the temperature by 10 [ddot]C approximately doubles the reaction rate.  相似文献   

12.
Glycosaminoglycan contents were evaluated in plasma and urine samples from volunteers treated intravenously with a mixture of dermatan sulphate and heparin, combining a novel liquid chromatographic-mass spectrometric technique for the determination of oligosaccharides from glycosaminoglycans with a classical technique for the extraction of glycosaminoglycans from biological samples (precipitation with cetylpyridinium chloride). In plasma samples dermatan sulphate and heparin can be measured for 2 h after treatment; urine excretion was detectable for 24 h. These results suggest that this novel approach is promising for future studies on the pharmacokinetics of glycosaminoglycans, although some technical aspects need further improvement, mainly regarding the procedures for sample clean-up; cetylpiridinium precipitation is a complex procedure and the recovery is limited.  相似文献   

13.
张晓艺  张秀尧  蔡欣欣  李瑞芬 《色谱》2018,36(10):979-984
建立了离子色谱-三重四极杆质谱测定血浆和尿液样品中氟乙酸(MFA)的方法。血浆样品经高氯酸超声提取,尿液样品经高氯酸酸化,血浆和尿液提取液在pH 0.5~1.0条件下用叔丁基甲醚(MTBE)萃取,萃取液经氮吹浓缩后溶于0.1%(v/v)氨水溶液。以Ionpac AS 19型阴离子色谱柱为分析柱,在线自动产生的氢氧化钾作为淋洗液进行梯度分离,柱流出液经阴离子抑制器抑制后进入质谱系统。采用电喷雾电离源,在负离子、多离子监测(MRM)模式下检测,13C2-氟乙酸稳定同位素内标法定量。血浆和尿液样品中氟乙酸的平均加标回收率为96.2%~120%,相对标准偏差为1.1%~13.1%(n=6),方法的检出限(S/N=3)分别为0.03 μg/L和0.1 μg/L。该法简单、灵敏、准确,可用于生物样品中氟乙酸的检测。  相似文献   

14.
High performance capillary electrophoresis using a buffer solution containing micelles of ionic surfactant (e.g. sodium dodecyl sulfate), called micellar electrokinetic chromatography, has been applied to the separation and simultaneous determination of creatinine and uric acid in human plasma and urine. The sample was introduced into the capillary by siphoning an appropriate volume of untreated plasma or urine spiked with an internal standard (antipyrine). Creatinine, uric acid, and antipyrine were separated mutually, and from other endogeneous components within 18 min. The calibration plots showed good linearity (correlation coefficient > 0.999) over the concentration range needed for clinical analysis. Standard addition tests indicated that the recoveries of creatinine and uric acid from urine samples ranged, respectively, from 97 % to 106 % and 97.4 % to 108 % with a coefficient of variation (C.V.) of 3.3 % (n = 5), and that those from plasma samples ranged, respectively, from 100 % to 112 % and 101 % to 107 % with a C.V. of 4.7 % (n = 5). The results were in agreement with those obtained by conventional methods.  相似文献   

15.
Quantitation of Zn‐DTPA (zinc diethylenetriamene pentaacetate, a metal chelate) in complex biological matrix is extremely challenging on account of its special physiochemical properties. This study aimed to develop a robust and specific liquid chromatography–tandem mass spectrometry (LC–MS/MS) method for determination of Zn‐DTPA in human plasma and urine. The purified samples were separated on Proteonavi (250 × 4.6 mm, 5 μm; Shiseido, Ginza, Tokyo, Japan) and a C18 guard column. The mobile phase consisted of methanol–2 mm ammonium formate (pH 6.3)–ammonia solution (50:50:0.015, v/v/v), flow rate 0.45 mL/min. The linear concentration ranges of the calibration curves for Zn‐DTPA were 1–100 μg/mL in plasma and 10–2000 μg/mL in urine. The intra‐ and inter‐day precisions for quality control (QC) samples were from 1.8 to 14.6% for Zn‐DTPA and the accuracies for QC samples were from −4.8 to 8.2%. This method was fully validated and successfully applied to the quantitation of Zn‐DTPA in plasma and urine samples of a healthy male volunteer after intravenous infusion administration of Zn‐DTPA. The result showed that the concentration of Zn‐DTPA in urine was about 20 times that in plasma, and Zn‐DTPA was completely (94.7%) excreted through urine in human.  相似文献   

16.
A capillary electrophoresis method with UV detection was developed for the determination of 8-hydroxy-2'-deoxyguanosine (8-OHdG) in untreated urine samples. The calibration graph for 8-OHdG in urine is linear in the concentration range 10-500 mg/l. and the detection limit is 5 mg/l (17 microM). 8-OHdG was determined in urine from oncological patients treated by radiation therapy. Its concentrations relative to creatinine were found to be in the range 10-47 microg 8-OHdG/l mg creatinine (4-19 micromol 8-OHdG/mmol creatinine). The overall time of the analysis of a urine sample was less than 15 min.  相似文献   

17.
A highly sensitive and selective high-performance liquid chromatographic method, involving sample pre-treatment, column switching and fluorimetric detection, is described for the determination of dihydroergotamine in plasma and urine samples. The pre-chromatographic sample treatment consists of extraction by means of an Extrelut column for plasma samples, and pre-separation with enrichment steps on a Sep-Pak column for urine samples. The samples are then injected onto a pre-separation column (Aquapore), and the fraction containing dihydroergotamine are automatically diverted onto an analytical column (ODS reversed phase). An acetonitrile-ammonium carbamate gradient is used as the mobile phase. High recovery of dihydroergotamine from both plasma (87%) and urine (100%) and a detection limit as low as 100 pg/ml were achieved, with a linear response up to 5 ng/ml. The assay demonstrated a high degree of selectivity with regard to the extensive metabolism of dihydroergotamine especially to the main metabolite 8'-hydroxydihydroergotamine. The assay was successfully applied for more than one year to the determination of plasma and urine concentrations of dihydroergotamine after parenteral administration.  相似文献   

18.
In the current study, two groups of rats (five per group) were administered a single oral dose of 500 mg/kg acetaminophen. For toxicokinetic assessment, the Group 1 animals were bled via conventional sparse (two animals/time point) sublingual vein bleeding (~0.5 ml) with anesthesia, while the Group 2 animals were bled via serial tail vein microsampling (~0.075 ml) without anesthesia. All collected blood was processed for plasma. Each Group 2 plasma sample (~30 μl) was divided into ‘wet’ and ‘dried’ (dried plasma spots). All plasma samples were analyzed by LC–MS/MS for acetaminophen and its major metabolites acetaminophen glucuronide and acetaminophen sulfate. In addition, plasma and urine samples were collected for analysis of corticosterone and creatinine to assess stress levels. Comparable plasma exposure to acetaminophen and its two metabolites was observed in the plasma obtained via conventional sparse sublingual vein bleeding and serial tail vein microsampling and between the ‘wet’ and ‘dried’ plasma obtained by the latter. Furthermore, comparable corticosterone levels or corticosterone/creatinine ratios between the two groups suggested that serial microsampling without anesthesia did not increase the levels of stress as compared with conventional sampling with anesthesia, confirming the utility of microsampling for plasma or dried plasma spots in rodent toxicokinetic assessment.  相似文献   

19.
林强  杨超  李美丽  王佳  侯瀚然  邵兵  牛宇敏 《色谱》2021,39(4):399-405
生物样品中脂溶性贝类毒素的检测,可为食物中毒等突发公共卫生事件的流行病学调查以及中毒者的临床救治提供技术支持.目前的研究存在目标化合物少,以及方法前处理复杂、灵敏度低等问题.该研究通过优化前处理和色谱分离技术,建立了超高效液相色谱-串联质谱法测定血浆、尿液中12种脂溶性贝类毒素的方法.实验对提取试剂以及流动相的选择进行...  相似文献   

20.
S Kr?ger 《The Analyst》1989,114(12):1647-1648
A gas chromatographic (GC) method was developed for the determination of 2-ethylhexanoic acid (2-EHA), initially in the urine of animals, but subsequently in samples of urine from sawmill workers in order to evaluate their exposure to 2-EHA which is used as a wood preservative. The 2-EHA was derivatised to the pentafluorobenzyl ester, which was then analysed by means of a cross-linked methyl silicone GC column with electron capture detection. Gas chromatography-mass spectrometry was used to confirm the identity of the GC peaks. The analytical range of the method was 0.03-2.70 mmol of 2-EHA per mol of creatinine in urine and the limit of detection was 0.01 mmol per mol of creatinine. The recovery of 2-EHA was 81-90% with a coefficient of variation of 9.8%. The amount of 2-EHA excreted in urine was corrected for the excretion of creatinine. The concentration of 2-EHA in the urine of the workers studied varied from 0.01 to 5.40 mmol per mol of creatinine; the median was 0.1 mmol per mol of creatinine.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号