首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
An analytical method for the determination of volatile and semi-volatile compounds representing various chemical groups in ice wines was developed and optimized in the presented study. A combination of the fully automated solid-phase microextraction (SPME) sample preparation technique and gas chromatographic-mass spectrometric (GC-MS) system to perform the final chromatographic separation and identification of the analytes of interest was utilized. A time-of-flight mass spectrometric (TOF-MS) analyzer provided very rapid analysis of this relatively complex matrix. Full spectral information in the range of m/z 35-450 was collected across the short GC run (less than 5 min). Divinylbenzene/Carboxen/Polydimethylsiloxane (DVB/CAR/PDMS) 50/30 microm fiber performed best during the optimization experiments and it was used in the headspace SPME mode to isolate compounds from ice wine samples, consisting of 3 mL wine with 1g salt addition. After the sample incubation and extraction (both 5 min at 45 degrees C), analytes were thermally desorbed in the GC injector for 2 min (injector maintained at 260 degrees C) and transferred into the column. The MS data acquisition rate of 50 spectra/s was selected as optimal. The optimized analytical method did not exceed 20 min per sample, including both the isolation and pre-concentration of the analytes of interest, the final GC-TOF-MS analysis and the fiber bake-out. Both a linear temperature-programmed retention index (LTPRI) method using C(8)-C(20) alkanes loaded onto the fiber and a mass spectral library search were employed to identify the target compounds. The repeatability of the developed and optimized HS-SPME-GC-TOF-MS method for ice wine analysis, expressed as relative standard deviation (RSD, %, n=7), ranged from 3.2 to 9.0%.  相似文献   

2.
DART (Direct Analysis in Real Time) coupled with Time‐of‐Flight Mass Spectrometry (TOF/MS) has been used for analyses of ice‐teas. The article focuses on quality and authenticity of ice‐teas as one of the most important tea‐based products on the market. Twenty‐one samples of ice‐teas (black and green) were analysed. Selected compounds of ice‐teas were determined: theobromine, caffeine, total phenolic compounds, total soluble solids, total amino acid concentration, preservatives and saccharides were determined. Fingerprints of DART‐TOF/MS spectra were used for comprehensive assessment of the ice‐tea samples. The DART‐TOF/MS method was used for monitoring the following compounds: citric acid, caffeine, saccharides, artificial sweeteners (saccharin, acesulphame K), and preservatives (sorbic and benzoic acid), phosphoric acid and phenolic compounds. The measured data were subjected to a principal components analysis. The HPLC and DART‐TOF/MS methods were compared in terms of determination of selected compounds (caffeine, benzoic acid, sorbic acid and saccharides) in the ice‐teas. The DART‐TOF/MS technique seems to be a suitable method for fast screening, testing quality and authenticity of tea‐based products. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

3.
Semivolatile organic compounds (SVOC) associated with ambient particles smaller than 2.5 microm (PM2.5) were determined in the city of Augsburg, Germany. Daily samples were collected at a central monitoring station from late summer 2002 to spring 2005. SVOC were analysed by direct thermal desorption (DTD)-GC and comprehensive 2-D GC coupled to TOF MS (DTD-GC-TOF MS and DTD-GC x GC-TOF MS). Two hundred compounds were quantified and 'semi-quantified' on a daily basis by DTD-GC-TOF MS. n-Alkanes, n-alkan-2-ones, n-alkanoic acid methyl esters, acetic acid esters, n-alkanoic acid amides, nitriles, linear alkylbenzenes and 2-alkyl-toluenes, hopanes, PAH, alkylated PAH and oxidised PAH, and several compounds that are not-grouped in homologous rows or compound classes were determined. Changes in concentration and pattern of several target compounds as well as methodological advantages and restrictions of DTD-GC-TOF MS are briefly discussed. DTD-GC-TOF MS analysis provided data particularly suited for source receptor modelling and epidemiological time series studies on the health effects of ambient PM. GC x GC enhances chromatographic resolution of PM samples and therefore amplifies the peak identification capabilities of the TOF MS.  相似文献   

4.
The determination of volatile and semi-volatile components of ice wine aroma was realized throughout the development of a rapid headspace solid-phase microextraction-gas chromatography-time-of-flight mass spectrometry (SPME-GC-TOF-MS) analytical method (Part I) and its application to the analysis of 137 samples produced in Canada and Czech Republic and collected directly from the producing wineries (Part II). In this Part III study, the complex matrix resulting from the analysis of the 58 compounds selected for each sample as described in Part II, was submitted to critical interpretation by using a self-organizing map (SOM) technique. Results were commented in terms of relative characterization of samples according to their geographical origin, grape varieties, and vintage years. When clear clustering was obtained, the most determinant compounds responsible for the observed differentiations were identified and further discussed.  相似文献   

5.
超高效液相色谱技术(UPLC)采用1.7 μm的色谱柱填料,有更好的分离效率、峰容量以及灵敏度;高分辨的时间飞行质谱(TOF-MS)能够测定化合物准确的分子质量并具有MS/MS功能。 两者的联用适合于复杂体系的分离分析和未知物的结构鉴定。 因此建立了一种基于UPLC/TOF-MS测定人参皂甙Rg3给药后大鼠尿液代谢物变化的方法,对其中2种发生显著变化的代谢物分别通过准确的质量测定得到其元素组成,通过MS/MS技术得到其结构信息,并通过检索数据库最终分别鉴定为4,8-二羟喹啉甲酸和4-羟基-2-喹啉酸。  相似文献   

6.
Different mass analysers [(quadrupole (Q), time-of-flight (TOF) and multicollector (MC) sector-field (SF)] of ions produced in an inductively coupled plasma were evaluated for the determination of lead isotope ratios in wine samples. A population of 20 wines of different origin including two reference wines from the EC Standards, Measurement and Testing Programme with concentrations varying between 7-140 mug Pb l(-1) was investigated. Wines were analyzed directly by Q ICP MS and MC ICP MS. The poor sensitivity of the TOF instrument, further aggravated by matrix signal suppression, did not allow the acquisition of data for wine samples that contained less than 50 mug l(-1) in the direct sample introduction mode. The separation and preconcentration of lead were therefore required. The precision obtained for the (206)Pb/(207)Pb and (208)Pb/(206)Pb were similar and equal to 0.14-2.7% for Q ICP MS, 0.04-0.17% for TOF ICP MS and 0.01-0.12% for MC ICP MS. The precision for (206)Pb/(204)Pb was 0.44-5.29, 0.15-1.7, 0.08-1.6%, respectively. On the level of accuracy, the data from TOF ICP MS and MC ICP MS were in good agreement. The accuracy of Q ICP MS data was judged satisfactory in comparison with the other techniques but their poor precision was a significant obstacle on the way of using these data for the determination of the geographic origin of wine.  相似文献   

7.
This study develops a method for the analysis of biocides Irgarol 1051 and Sea Nine 211 in environmental water samples, using solid-phase microextraction (SPME). Their determination was carried out using gas chromatography with flame thermionic (FTD), electron-capture (ECD) and mass spectrometric detection. The main parameters affecting the SPME process such as adsorption-time profile, salt additives and memory effect were studied for five polymeric coatings commercially available for solid-phase microextraction: poly(dimethylsiloxane) (100 and 30 microm), polyacrylate, poly(dimethylsiloxane)-divinylbenzene (PDMS-DVB 65 microm) and Carbowax-divinylbenzene (65 microm). The method was developed using spiked natural waters such as tap, river, sea and lake water in a concentration range of 0.5-50 microg/l. All the tested fiber coatings have been evaluated with regard to sensitivity, linear range, precision and limits of detection. Typical RSD values (triplicate analysis) in the range of 3-10% were obtained depending on the fiber coating and the compound investigated. The recoveries of biocides were in relatively high levels 60-118% and the calibration curves were reproducible and linear (R2>0.990) for both analytes. The SPME partition coefficients (Kf) of both compounds were also calculated experimentally in the proposed conditions for all fibers using direct sampling. Finally the influence of organic matter such as humic acids on extraction efficiency was studied, affecting mostly Sea Nine 211 uptake by the fiber. Optimum analytical SPME performance was achieved using the PDMS-DVB 65 microm fiber coating in ECD and FTD systems for Sea Nine 211 and Irgarol 1051, respectively.  相似文献   

8.
Liquid chromatography coupled to orthogonal acceleration time-of-flight mass spectrometry (LC/TOF) provides an attractive alternative to liquid chromatography coupled to triple quadrupole mass spectrometry (LC/MS/MS) in the field of multiresidue analysis. The sensitivity and selectivity of LC/TOF approach those of LC/MS/MS. TOF provides accurate mass information and a significantly higher mass resolution than quadrupole analyzers. The available mass resolution of commercial TOF instruments ranging from 10 000 to 18 000 full width at half maximum (FWHM) is not, however, sufficient to completely exclude the problem of isobaric interferences (co-elution of analyte ions with matrix compounds of very similar mass). Due to the required data storage capacity, TOF raw data is commonly centroided before being electronically stored. However, centroiding can lead to a loss of data quality. The co-elution of a low intensity analyte peak with an isobaric, high intensity matrix compound can cause problems. Some centroiding algorithms might not be capable of deconvoluting such partially merged signals, leading to incorrect centroids.Co-elution of isobaric compounds has been deliberately simulated by injecting diluted binary mixtures of isobaric model substances at various relative intensities. Depending on the mass differences between the two isobaric compounds and the resolution provided by the TOF instrument, significant deviations in exact mass measurements and signal intensities were observed. The extraction of a reconstructed ion chromatogram based on very narrow mass windows can even result in the complete loss of the analyte signal. Guidelines have been proposed to avoid such problems. The use of sub-2 microm HPLC packing materials is recommended to improve chromatographic resolution and to reduce the risk of co-elution. The width of the extraction mass windows for reconstructed ion chromatograms should be defined according to the resolution of the TOF instrument. Alternative approaches include the spiking of the sample with appropriate analyte concentrations. Furthermore, enhanced software, capable of deconvoluting partially merged mass peaks, may become available.  相似文献   

9.
A benchtop high-resolution time-of-flight mass spectrometer (TOF MS) was evaluated for the determination of key organic microcontaminants. The major advantage of the TOF MS proved to be the high mass resolution of about 0.002 Da (10 ppm). Consequently, the detectability of polar pesticides, polynuclear aromatic hydrocarbons and polychlorinated biphenyls is excellent, and detection limits are in the order of 1–4 pg injected mass. Best mass spectral resolution was obtained for medium-scale peaks. It is a disadvantage that the calibration range is rather limited, viz. to about two orders of magnitude. The high mass spectral resolution was especially useful to improve the selectivity and sensitivity when analyzing target compounds in complex samples and to prevent false-positive identifications.  相似文献   

10.
This study presents the optimization and application of an analytical method based on the use of stir bar sorptive extraction (SBSE) gas chromatography coupled to mass spectrometry (GC–MS) for the ultra-trace analysis of POPs (Persistent Organic Pollutants) in Arctic ice. In a first step, the mass-spectrometry conditions were optimized to quantify 48 compounds (polycyclic aromatic hydrocarbons, brominated diphenyl ethers, chlorinated biphenyls, and organochlorinated pesticides) at the low pg/L level. In a second step, the performance of this analytical method was evaluated to determine POPs in Arctic cores collected during an oceanographic campaign. Using a calibration range from 1 to 1800 pg/L and by adjusting acquisition parameters, limits of detection at the 0.1–99 and 102–891 pg/L for organohalogenated compounds and polycyclic aromatic hydrocarbons, respectively, were obtained by extracting 200 mL of unfiltered ice water. α-hexachlorocyclohexane, DDTs, chlorinated biphenyl congeners 28, 101 and 118 and brominated diphenyl ethers congeners 47 and 99 were detected in ice cores at levels between 0.5 to 258 pg/L. We emphasise the advantages and disadvantages of in situ SBSE in comparison with traditional extraction techniques used to analyze POPs in ice.  相似文献   

11.
Atenolol, nadolol, metoprolol, bisoprolol and betaxolol were simultaneously determined in groundwater samples by large‐volume injection coupled‐column reversed‐phase liquid chromatography with fluorescence detection (LVI‐LC‐LC‐FD) and liquid chromatography‐time‐of‐flight mass spectrometry (LC‐TOF‐MS). The LVI‐LC‐LC‐FD method combines analyte isolation, preconcentration and determination into a single step. Significant reductions in costs for sample pre‐treatment (solvent and solid phases for clean up) and method development times are also achieved. Using LC‐TOF‐MS, accurate mass measurements within 3 ppm error were obtained for all of the β‐blockers studied. Empirical formula information can be obtained by this method, allowing the unequivocal identification of the target compounds in the samples. To increase the sensitivity, a solid‐phase extraction step with Oasis MCX cartridge was carried out yielding recoveries of 79–114% (n=5) with RSD 2–7% for the LC‐TOF‐MS method. SPE gives a high purification of β‐blockers compared with the existing methods. A 100% methanol wash was allowed for these compounds with no loss of analytes. Limit of quantification was 1–7 ng/L for LVI‐LC‐LC‐FD and 0.25–5 ng/L for LC‐TOF‐MS. As a result of selective extraction and effective removal of coextractives, no matrix effect was observed in LVI‐LC‐LC‐FD and LC‐TOF‐MS analyses. The methods were applied to detect and quantify β‐blockers in groundwater samples of Almería (Spain).  相似文献   

12.
The presence of a wide variety of organic pollutants with different physicochemical characteristics has been investigated in wastewater samples from a municipal solid-waste-treatment plant in Castellón, Spain. An advanced analytical strategy was applied—combined used of two powerful and complementary techniques, GC and LC, both hyphenated with tandem mass spectrometry with triple-quadrupole analyzers. The GC–MS–MS method was based on sample extraction using C18 SPE cartridges and enabled the determination of approximately 60 compounds from different chemical families, for example PAHs, octyl/nonylphenols, PCBs, organochlorine compounds, insecticides, herbicides, and PBDEs. Most of the compounds selected are included as priority contaminants in the European Union (EU) Water Directive. The UHPLC–MS–MS method, which provided high chromatographic resolution and sensitivity and short analysis time, used sample extraction with Oasis HLB SPE cartridges and enabled the determination of 37 (more polar) pesticides. The methodology developed was applied to the analysis of 41 water samples (20 untreated raw leachates and 21 treated samples) collected between March 2007 and February 2009. Amounts of the contaminants investigated rarely exceeded 0.5 μg L−1 in the treated (reverse osmosis) water samples analyzed. As expected, in untreated leachates the number of compounds detected and the concentrations found were notably higher than in treated waters. The most commonly detected pollutants were herbicides (simazine, terbuthylazine, terbutryn, terbumeton, terbacil, and diuron), fungicides (thiabendazole and carbendazim), and 4-t-octylphenol. The results obtained proved that use of reverse osmosis for water treatment was efficient and notably reduced the amounts of organic contaminants found in raw leachate samples. In order to investigate the presence of other non-target contaminants, water samples were also analyzed by using GC–TOF MS and LC–QTOF MS. Several organic pollutants that did not form a part of the previous list of target contaminants were identified in the samples, because of the high sensitivity of TOF MS in full-spectrum acquisition mode and the valuable accurate-mass information provided by these instruments. The insecticide diazinon, the fungicide diphenylamide, the UV filter benzophenone, N-butylbenzenesulfonamide (N-BBSA), the insect repellent diethyltoluamide, caffeine, and the pharmaceuticals erythromycin, benzenesulfonanilide, ibuprofen, atenolol, and paracetamol were some of the compounds identified in the water samples analyzed.  相似文献   

13.
Liquid chromatography/ultraviolet (LC/UV) and mass spectrometry/mass spectrometry (MS/MS) libraries containing 39 phenolic compounds were established by coupling a LC and an ion trap MS with an electrospray ionization (ESI) source, operated in negative ion mode. As a result, the deprotonated [M-H]- molecule was observed for all the analyzed compounds. Using MS/MS hydroxybenzoic acid and hydroxycinnamic acids showed a loss of CO2 and production of a [M-H-44]- fragment and as expected, the UV spectra of these two compounds were affected by their chemical structures. For flavonol and flavonol glycosides, the spectra of their glycosides and aglycones produced deprotonated [M-H]- and [A-H]- species, respectively, and their UV spectra each presented two major absorption peaks. The UV spectra and MS/MS data of flavan-3-ols and stilbenes were also investigated. Using the optimized LC/MS/MS analytical conditions, the phenolic extracts from six representative wine samples were analyzed and 31 phenolic compounds were detected, 26 of which were identified by searching the LC/UV and MS/MS libraries. Finally, the presence of phenolic compounds was confirmed in different wine samples using the LC/UV and LC/MS/MS libraries.  相似文献   

14.
Niri VH  Pawliszyn J 《The Analyst》2007,132(5):425-430
This paper describes an in-fiber standardization method by Solid Phase Microextraction (SPME) for the determination of a sample volume. After loading a specific amount of standard, the volumetric standard, on a PDMS-coated fiber (n(0)), the fiber was exposed in the headspace of sample vials containing different volumes of water. The amount of standard that remained on the fiber after equilibrium (n(f)), which was determined with gas chromatography/mass spectrometry (GC/MS), depends on the volume of the sample. Naphthalene, 1-methylnaphthalene, 2-methylnaphthalene, 1-ethylnaphthalene, and 2-ethylnaphthalene were chosen as volumetric standards based on theoretical calculations. The effect of loading time, exposure time, and exposure temperature were investigated. The effect of the matrix was also studied, analyzing both water and wine samples. Precision and accuracy of the method were obtained for each standard in both water and wine. The partition coefficients of the compounds between the fiber and the sample (K(fs)) and between the headspace and the sample (K(hs)) were obtained by plotting n(0)/n(f)versus sample volume.  相似文献   

15.
Particle-particle pulloff adherence forces were measured as a function of temperature in the ice/n-decane/ice and tetrahydrofuran (THF) hydrate/n-decane/THF hydrate systems using a newly developed micromechanical testing technique. Experiments using approximately 200 microm radius particles were performed at atmospheric pressure over the temperature range 263-275 K. The ice and hydrate particles displayed very similar behavior. While the measured adherence forces had significant variation, the shapes of the cumulative force distribution curves were similar among the different sets of experiments. The measured adherence forces distributions shifted to lower force values as the temperature was decreased from the solid melting temperature. The observed forces and trends were explained by the capillary cohesion of rough surfaces, with the capillary bridging liquid being stabilized below its freezing point by the negative curvature of the bridging liquid/n-decane interface.  相似文献   

16.
Emerging contaminants from wastewater effluent samples were analysed, using posttarget and nontarget analysis techniques. The samples were analysed with an ultra performance liquid chromatograph‐time‐of‐flight mass spectrometer (UPLC‐TOF‐MS), and the resulting data were processed with commercial deconvolution software. The method works well for posttarget analysis with prior information about the retention times of the compounds of interest. With positive polarity, 63 of 66 compounds and with negative polarity, 18 of 20 compounds were correctly identified in a spiked sample, while two compounds of a total of 88 fell out of the mass range. Furthermore, a four‐stage process for identification was developed for the posttarget analysis lacking the retention time data. In the process, the number of candidate compounds was reduced by using the accurate mass of selected compounds in two steps (stages 1 and 2), structure–property relationships (stage 3) and isotope patterns of the analytes (stage 4). The process developed was validated by analysing wastewater samples spiked with 88 compounds. This procedure can be used to gain a preliminary indication of the presence of certain analytes in the samples. Nontarget analysis was tested by applying a theoretical mass spectra library for a wastewater sample spiked with six pharmaceuticals. The results showed a high number of false identifications. In addition, manual processing of the data was considered laborious and ineffective. Finally, the posttarget analysis was applied to a real wastewater sample. The analysis revealed the presence of six compounds that were afterwards confirmed with standard compounds as being correct. Three psycholeptics (nordiazepam, oxazepam and temazepam) could be tentatively identified, using the identification process developed. Posttarget analysis with UPLC‐TOF‐MS proved to be a promising method for analysing wastewater samples, while we concluded that the software for nontarget analysis will need improvement before it can be used in environmental analytical work with LC‐TOF‐MS systems. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

17.
Chen X  Zhao Y  Yao S  Li X  Jin M 《色谱》2011,29(12):1147-1154
建立了一种专属、灵敏的同时测定黄酒和葡萄酒中安赛蜜、糖精、甜蜜素、阿斯巴甜、苯甲酸、山梨酸、甜菊糖苷、纽甜和脱氢乙酸等9种防腐剂和甜味剂的超快速液相色谱-串联质谱(UFLC-MS/MS)分析方法。不同类型的黄酒和葡萄酒经纯水稀释后,以乙腈和0.01%三氟乙酸-2.5 mmol/L乙酸铵水溶液为流动相,采用梯度洗脱方式在Shim-pack XR-ODSII色谱柱(100 mm×2.0 mm, 2.2 μm)上进行分离,以电喷雾负离子多反应监测(MRM)模式进行质谱分析。实验表明,9种防腐剂和甜味剂在检测范围内均具有良好的线性关系(r2>0.998);方法的检出限(以信噪比大于3计)为0.03~15.0 μg/L,定量限(以信噪比大于10计)为0.1~50.0 μg/L;在黄酒中的回收率为96.2%~100.5%,相对标准偏差(RSDs)为0.6%~5.4%;在葡萄酒中的回收率为96.0%~104.0%, RSDs为0.7%~4.8%。同时研究了这9种防腐剂和甜味剂的二级质谱特征,阐释了其二级质谱裂解途径。本方法灵敏度高、重现性好、分析速度快,可用于黄酒和葡萄酒中防腐剂和甜味剂的快速确证检测。  相似文献   

18.
Carbonyl compounds (aldehydes and ketones) are suspected to be among the chemical compounds responsible for Sick Building Syndrome and Multiple Chemical Sensitivities. A headspace gas chromatography/mass spectrometry (GC/MS) analysis for these compounds was developed using derivatization of the compounds into volatile derivatives with o-(2,3,4,5,6-pentafluorobenzyl)hydroxylamine (PFBOA). For GC/MS detection, two ionization modes including electron impact ionization (EI) and negative chemical ionization (NCI) were compared. The NCI mode seemed to be better because of its higher selectivity and sensitivity. This headspace GC/MS (NCI mode) was employed as analysis for aldehydes and ketones in materials (fiber products, adhesives, and printed materials). Formaldehyde was detected in the range of N.D. (not detected) to 39 microg/g; acetaldehyde, N.D. to 4.1 microg/g; propionaldehyde, N.D. to 1.0 microg/g; n-butyraldehyde, N.D. to 0.10 microg/g; and acetone, N.D. to 3.1 microg/g in the samples analyzed.  相似文献   

19.
The performance of three different types of mass spectrometers (MS) coupled to high performance liquid chromatography (HPLC) was compared for trace analysis of perfluoroalkylated substances (PFAS) and fluorotelomer alcohols (FTOHs). Ion trap MS in the full scan and product ion MS2 mode, time-of-flight (TOF) high resolution MS and quadrupole MS in the selected ion mode as well as triple quadrupole tandem MS were tested. Electrospray ionisation in the negative ion mode [ESI-] was best suited for all instruments and compounds. PFAS could only be separated by a buffered mobile phase, but the presence of buffer suppressed the ionisation of FTOHs. Therefore, two independent chromatographic methods were developed for the two compound classes. Mass spectra and product ion spectra obtained by in-source and collision induced dissociation fragmentation are discussed including ion adduct formation. Product ion yields of PFAS were only in the range of 0.3 to 12%, independent from the applied MS instrument. Ion trap MS2 gave product ion yields of 20 to 62% for FTOHs, whereas only 4.1 to 5.8% were obtained by triple quadrupole tandem MS. Ion trap MS was best suited for qualitative analysis and structure elucidation of branched isomeric structures of PFAS. Providing typical detection limits of 5 ng injected in MS2 mode, it was not sensitive enough for selective trace amount quantification. TOF high resolution MS was the only technique combining high selectivity and excellent sensitivity for PFAS analysis (detection limits of 2 to 10 pg), but lacked the possibility of MS-MS. Triple quadrupole tandem MS was the method of choice for quantification of FTOHs with detection limits in the low pg range. It is also well suited for the determination of PFAS, though its detection limits of 10 to 100 pg in tandem MS mode are about one order of magnitude higher than for TOF MS.  相似文献   

20.
A rapid multiresidue method for the analysis of 72 pesticides has been developed using a single injection with low-pressure gas chromatography/tandem mass spectrometry (LP-GC/MS/MS). The LP-GC/MS/MS method used a short capillary column of 10 m x 0.53 mm i.d. x 0.25 microm film thickness coupled with a 0.6 m x 0.10 mm i.d. restriction at the inlet end. Optimal LP-GC conditions were determined which achieved the fastest separation in MS/MS detection mode. Also MS/MS conditions were optimized in order to increase sensitivity and selectivity. The analytical parameters of the LP-GC/MS/MS method were compared with those obtained by GC/MS/MS using a conventional capillary column (30 m x 0.25 mm i.d. x 0.25 microm film thickness). Better precision and sensitivity values were obtained with the LP-GC/MS/MS approach. The limits of detection (LOD) of the compounds ranged from 0.1 to 14.1 microg L(-1) for LP-GC/MS/MS, lower than those obtained for conventional GC/MS/MS that ranged from 0.1 to 17.5 microg L(-1). The peak widths obtained with the short column in LP-GC are similar to those obtained using conventional capillary GC columns, and the peaks can be successfully identified by MS/MS detection with the conventional scan speed of ion-trap instruments. In addition, the analysis time was significantly reduced with LP-GC/MS/MS (32 min) versus GC/MS/MS (72 min), allowing the number of samples analyzed per day in a routine laboratory to be doubled.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏