首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Enrofloxacin (ENR) and its metabolite ciprofloxacin (CIP) were determined by capillary zone electrophoresis (CZE) with end-column amperometric detection. The effect of several factors, such as pH and concentration of running buffer solution, separation voltage, injection time, and working potential, on CZE were investigated to establish the optimal conditions of separation and detection. Under a given set of conditions (pH 8.00 phosphate buffer solution (20 mmol/L); +0.95 V for the working potential; 18 kV for the separation voltage; sample injection at 18 kV for 10 s), the compounds investigated can be well separated and detected within 8 min. Excellent linearity was observed between peak currents and concentration of analytes in the range from 0.034 to 70.0 mg/kg for these two compounds. The detection limits (S/N= 3) for enrofloxacin and ciprofloxacin were 13.68 mg/kg and 14.35 mg/kg, respectively, which were about 7-fold lower than the maximum residue limits (MRLs) established by the European Union. A simple sample pretreatment method was developed and proved to be effective in obtaining good recoveries and short analysis time. The developed CE-AD method was simpler, faster, and less cost intensive than other reported methods, and allows the determination of ENR and its metabolite CIP in contaminated eel liver samples and other animal tissue samples at the required maximum residue limits.  相似文献   

2.
毛细管电泳-激光诱导荧光检测法测定抗癫痫药加巴喷丁   总被引:1,自引:0,他引:1  
蔡元丽  杨甲甲  王宇飞  白珂珂  李晖 《色谱》2010,28(12):1179-1184
建立了毛细管电泳-激光诱导荧光(CE-LIF)测定抗癫痫药加巴喷丁的方法。加巴喷丁经4-氯-7-硝基苯并-2-氧杂-1,3-二唑(NBD-Cl)衍生化后,采用10 mmol/L硼砂-10 mmol/L十二烷基硫酸钠(pH 9.75)的缓冲体系,加巴喷丁在6 min内实现高效基线分离。方法的线性范围为0.01~10 mg/L(r=0.9997),检出限为2 μg/L,定量限为10 μg/L。方法的平均回收率为100.2%~103.1%,相对标准偏差为0.15%~1.00%(n=3)。该方法灵敏、快速、准确和可靠,已用于加巴喷丁药物制剂的质量控制。  相似文献   

3.
High-dosage methotrexate therapy requires careful monitoring of the drug in serum to ensure minimal toxic effects. A simple, rapid and sensitive method for the separation and quantitation of methotrexate and its major metabolite, 7-hydroxymethotrexate, using high-voltage capillary zone electrophoresis combined with laser-induced fluorescence detection is described. The detection limit for methotrexate is as low as 5.10(-10) M (signal-to-noise ratio = 3), while that for 7-hydroxymethotrexate is 2.10(-9) M. The linearity of the system extends over nearly four orders of magnitude for both methotrexate and 7-hydroxymethotrexate. The extraction efficiency for the drug and its metabolite from serum is 80-85% using a Sep-Pak C18 cartridge. Quantitation of methotrexate in serum was possible in the 10(-10) M range, nearly two orders of magnitude lower than that currently obtainable by existing methods. Good correlation (r = 0.99) for serum methotrexate concentrations was obtained with an enzyme-multiplied immunoassay technique. Comparison with an enzyme inhibition assay also provided similar results.  相似文献   

4.
Phycobiliproteins are derived from the photosynthetic apparatus of cyanobacteria and eukaryotic algae. They are composed of a protein backbone to which linear tetrapyrrole chromophores are covalently bound. Furthermore, they are water-soluble highly fluorescent, and relatively stable at room temperature and neutral pH. For this reason, capillary electrophoresis-laser induced fluorescence (CE-LIF) seems the idea method for determination of these important proteins. The effects of buffer additives such as sodium dodecyl sulfate (SDS)and putrescine on the separation of the three major phycobiliprotein types, namely allophycocyanin, phycocyanin, and phycoerythrin, with excitation and emission maxima at 652/660, 615/647, and 565(494)/575 nm, respectively, are considered. Detection limits for these proteins by CE-LIF are some 60-500 times better than by absorbance detection. The development of a fast and sensitive CE-LIF assay such as this is of potential significance to our understand ing of chemical and biological oceanographic processes.  相似文献   

5.
The industrial application of nitrocellulose depends on its nitrogen content. When nitrocellulose presents high nitrogen content is used in the manufacture of explosives whereas nitrocellulose with low nitrogen content is used to make a wide range of daily and non-explosive products (e.g. cigarettes, paints, lacquers). This fact makes really important to develop a method for the determination and discrimination of nitrocellulose samples. This work reports, for the first time, the qualitative determination of nitrocellulose previously derivatized with 8-aminopyrene-1,3,6-trisulfonic acid (APTS) by capillary electrophoresis (CE-LIF) with laser-induced fluorescence detection (CE-LIF). APTS-labeled nitrocellulose was determined in lowly and highly nitrated nitrocellulose samples present in collodions and smokeless gunpowders, respectively, after their pulverization in liquid nitrogen. The method described enables the visual discrimination of different nitrocelluloses on the basis of the different electrophoretic profiles obtained, and provides a useful tool to determine nitrocellulose. Additionally, the use of field-amplified sample injection (FASI) enabled enhanced sample detection, which made it possible to determine nitrocellulose contained in ∼15 μg of gunpowder.  相似文献   

6.
Liu X  Ma L  Lin YW  Lu YT 《Journal of chromatography. A》2003,1021(1-2):209-213
A novel method based on capillary electrophoresis coupled to laser-induced fluorescence detection (CE-LIF) was developed for the determination of abscisic acid (ABA), which is an essential phytohormone during plant growth and development. ABA was labeled with 8-aminopyrene-1,3,6-trisulfonate via reductive amination in presence of acetic acid and sodium cyanoborohydride. The derivatization yield was maximized by optimizing several derivatization parameters including derivatization reagent concentration, reaction temperature and time. The conjugate was separated and quantitated by CE-LIF. The linearity of ABA was determined in the range from 0.1 to 10 micromol l(-1) with a correlation of 0.9979. The derivatization limit of detection for ABA was found to be 56 fmol (corresponding to the concentration of 2.8 x 10(-8) mol l(-1)). The detection limit for ABA was 5.5 amol for an injection volume of 5 nl. As a preliminary application, the proposed method was successfully applied to determining trace amount of ABA in the crude extracts of tobacco without extra purification and enrichment procedure and showed a better selectivity and sensitivity than those conventional methods used in determination of ABA.  相似文献   

7.
This work described a sensitive method for determination of metoprolol in rabbit plasma.The method involved purification by ultrafiltration,derivatization with fluorescein isothiocyanate,determination by capillary electrophoresis(CE) coupled with laser-induced fluorescence(LIF) detector.Other components in plasma including a variety of amino acids and proteins did not interfere with the determination of metoprolol in experimental condition.The assay had a wide range(2.0-500 ng/mL) of linearity and a detection limit of 0.8 ng/mL.The intra- and inter-day precisions were satisfactory with relative standard deviation(RSD) less than 10.0%and accuracy within 10.0%.This method was successfully applied to pharmacokinetic study of metoprolol in rabbit blood.  相似文献   

8.
A sensitive capillary electrophoresis –laser-induced fluorescence method has been developed for the determination of six fluoroquinolones of human (ofloxacin, lomefloxacin, and norfloxacin) and veterinary use (danofloxacin, enrofloxacin, and sarafloxacin) in different kinds of water. Fluorescence detection was achieved using a He-Cd laser, with a wavelength of 325 nm. Separation was performed in a fused-silica capillary, and conditions were optimized to obtain the most adequate separation and with the best sensitivity. The separation was carried out in a 70-cm-long capillary (75 μm internal diameter, effective length 55 cm) by using a 125 mM phosphoric acid separation buffer at pH 2.8, with 36% of methanol. The water sample pretreatment involved the separation and preconcentration of the analytes by solid phase extraction. Two reverse-phase cartridges have been evaluated, namely Oasis hydrophilic–liphophilic balance and Strata-X; the latter provided the best recoveries for the selected analytes. The method shows very low detection limits (0.3–1.9 ng/L) with acceptable recoveries and precisions and has been successfully applied to the analysis of well and tap water samples.  相似文献   

9.
McWhorter S  Soper SA 《Electrophoresis》2000,21(7):1267-1280
As capillary electrophoresis continues to focus on miniaturization, either through reducing column dimensions or situating entire electrophoresis systems on planar chips, advances in detection become necessary to meet the challenges posed by these electrophoresis platforms. The challenges result from the fact that miniaturization requires smaller load volumes, demanding highly sensitive detection. In addition, many times multiple targets must be analyzed simultaneously (multiplexed applications), further complicating detection. Near-infrared (NIR) fluorescence offers an attractive alternative to visible fluorescence for critical applications in capillary electrophoresis due to the impressive limits of detection that can be generated, in part resulting from the low background levels that are observed in the NIR. Advances in instrumentation and fluorogenic labels appropriate for NIR monitoring have led to a growing number of examples of the use of NIR fluorescence in capillary electrophoresis. In this review, we will cover instrumental components used to construct ultrasensitive NIR fluorescence detectors, including light sources and photon transducers. In addition, we will discuss various types of labeling dyes appropriate for NIR fluorescence and finally, we will present several applications that have used NIR fluorescence in capillary electrophoresis, especially for DNA sequencing and fragment analysis.  相似文献   

10.
Capillary electrophoresis with postcolumn laser-induced fluorescence detection was used to individually detect 6.0, 1.0, 0.5, and 0.2 num diameter polystyrene microspheres and individually measure their electrophoretic mobility. The analysis of a nanoliter-size volume from a microsphere suspension results in an electropherogram characterized by several narrow spikes in a well-defined migration time window. Each spike is associated with one microsphere because, when one single microsphere is introduced into the capillary by micromanipulation, the electropherogram has only one spike in the same migration time window. The distributions of individual measurements resulting from an electropherogram were used to evaluate the reproducibility from run to run, observe the effect of sodium dodecyl sulfate (SDS) added to the running buffer, and to investigate the origin of electrophoretic dispersion. As expected from the interactions between microspheres and SDS, the addition of this surfactant to the running buffer narrowed the range and shifted the average electrophoretic mobility to more negative values. After evaluating common sources of broadening in capillary electrophoresis, electrophoretic dispersion was attributed to microsphere heterogeneity. Unlike electropherograms displaying Gaussian-like profiles, the two-dimensional representations of the individual measurements provide a new alternative to evaluate and study electrophoretic-related properties of microspheres.  相似文献   

11.
Summary A novel method of separating and detecting trace aluminum by capillary zone electrophoresis is described. Aluminum is reacted with lumogallion [4-chloro-3-(2,4-dihydroxyphenylazo)-2-hydroxybenzen-1-sulphonic acid] so that the complex can be selectively and sensitively detected by a laser-induced fluorescence detector after capillary electrophoretic separation. Using the proposed method, limits of detection in the sub parts per billion range are achieved. The technique is applied to the determination of aluminum in human serum.  相似文献   

12.
汪雪雁  檀华蓉  祁克宗  邵黎  李慧  薛秀恒  谢英 《色谱》2010,28(11):1107-1110
以恩诺沙星为模板分子,α-甲基丙烯酸为功能单体,二甲基丙烯酸乙二醇酯为交联剂,制备了恩诺沙星分子印迹聚合物。以该分子印迹聚合物为固相萃取材料,采用高效毛细管电泳分离方式,建立了分子印迹固相萃取-高效毛细管电泳检测鸡肉中恩诺沙星的方法。结果表明,该方法能有效地萃取和检测鸡肉中的恩诺沙星。在优化条件下,恩诺沙星的检出限为92.02 μg/kg,定量限为336.04 μg/kg;不同恩诺沙星添加水平下的回收率为77.84%~86.52%,相对标准偏差为2.18%~3.76%。该方法适用于鸡肉中恩诺沙星残留的测定。  相似文献   

13.
Two methods for monosaccharide analysis by capillary electrophoresis (CE) using counterelectroosmotic and coelectroosmotic modes with indirect laser-induced fluorescence detection were optimised and compared. A mixture of seven glycosaminoglycan-derived hexoses was separated in alkaline fluorescein-based electrolytes and detected in both counterelectroosmotic and coelectroosmotic conditions. The fluorescein concentration and pH of the background electrolyte, and the influence of the reversal of electroosmotic flow by addition of hexadimethrine bromide on the separation were studied. Coelectroosmotic CE conditions provided better resolution and limits of detection. A 10(-6) M fluorescein solution at pH 12.25 containing 0.0005% (w/v) hexadimethrine bromide was used as background electrolyte. Quality parameters such as run-to-run, day-to-day precision and limits of detection were calculated, and better figures of merit were obtained for the coelectrooosmotic conditions than for the counterelectroosmotic mode. The coelectroosmotic method was applied to the quantitation of the hexosamine contents in glycosaminoglycans after acid hydrolysis. The method proved to be suitable for the determination of dermatan sulfate in heparin down to 2% (w/w).  相似文献   

14.
In this study, we developed a novel assay that simultaneously detects multiple miRNAs (microRNAs) within a single capillary by combining a tandem adenosine-tailed DNA bridge-assisted splinted ligation with denaturing capillary gel electrophoresis with laser-induced fluorescence. This proposed method not only represents a significant improvement in resolution but also allows for the detection of multiple miRNAs within a single capillary based on the length differences of specified target bridge DNA. The assay's linear range covers three orders of magnitude (1.0 nM to 1.0 pM) with a limit of detection (S/N=3) as low as 190 fM (2.5 zmol). Five miRNAs of Epstein-Barr virus (EBV) were also detected in EBV-infected nasopharyngeal carcinoma cells, while they did not appear in non-virus infected cells. Moreover, the electropherogram indicated that the screening of isomiRs (isomer of miRNA) of BART2 by CE-LIF is feasible by our proposed method. The developed electrophoresis-based method for miRNA detection is fast, amplification-free, multiplexed and cost-effective, making it potentially applicable to large-scale screening of isomiRs.  相似文献   

15.
Chan KC  Muschik GM  Issaq HJ 《Electrophoresis》2000,21(10):2062-2066
Two solid-state UV lasers were applied to the laser-induced fluorescence (LIF) detection of various groups of compounds after separation by capillary electrophoresis. These lasers are thermoelectric-cooled, highly compact, and inexpensive. Such lasers provide few mW of quasi-continuous wave (CW) power which are sufficient and stable for LIF detection. Native fluorescence detection of tryptophan-containing proteins and peptides and related indoles was achieved at the nM level with the laser operating at 266 nm. Detection of fluorescamine-labeled amino acids and peptides was also possible at the nM level with the laser operating at 355 nm. Amino acids at a concentration as low as 10 ng/mL could be labeled with fluorescamine. Solid-state UV-LIF detection of the tryptic digest of cytochrome c after fluorescamine derivatization was demonstrated.  相似文献   

16.
Hirudin, a thrombin inhibitor, is a polypeptide of 65 amino acids. To check purity levels and perform pharmacokinetic studies of recombinant hirudin (r-hirudin), a specific and reproducible analysis method is required. Capillary electrophoresis (CE) is rapidly becoming an important procedure for the analysis of biological molecules. Recently, CE combined with immunoassay has emerged as a new analytical technique. CE-based immunoassay (CEIA) is a sensitive and specific method combining laser-induced fluorescence (LIF) and immunoassay. Therefore, in this study, we specifically investigated fluorescence labeling and determination of r-hirudin by CEIA with a LIF detector using labeled r-hirudin and polyclonal antibody. r-Hirudin was labeled with fluorescein isothiocyanate (FITC). FITC-labeled r-hirudin was purified using high-performance liquid chromatography (HPLC). The method is based on preincubation of r-hirudin and antibody for 20 min, followed by CE analysis using an uncoated capillary. Free and bound r-hirudin were separated within 5 min using CE with high reproducibility. This study demonstrated that the CEIA method could be applied to quantitative analysis of r-hirudin in biological fluids.  相似文献   

17.
A new analytical method for baclofen (4-amino-3-p-chlorophenylbutyric acid) based on capillary electrophoretic separation and laser-induced fluorescence detection has been developed. Naphthalene-2,3-dicarboxaldehyde was used for precolumn derivatization of the non-fluorescent drug. Optimal separation and detection were obtained with an electrophoretic buffer of 50 mM sodium borate (pH 9.5) and a He-Cd laser (excitation at 442 nm, emission at 500 nm). Linearity (r > or = 0.99) over three orders of magnitude was generally obtained and the concentration limit of detection was in the nanomolar level. Coupled with a simple cleanup procedure, the method was successfully applied to the analysis of baclofen in human plasma. Recovery of spiked baclofen in plasma was 98%. The relative standard deviation values on peak size and migration time were 7.9% and 0.4%, respectively. The limit of detection of baclofen in plasma was 10 ng/ml.  相似文献   

18.
Indirect LIF detection was applied to the detection of four acidic diuretics separated by CZE. Semiconductor laser was employed to provide the stable excitation of 473 nm. With an optimized electrophoretic buffer system which contained 5 mM of triethylamine, 0.1 microM of fluorescein, and 5% of n-butanol, fast separation of four diuretics (ethacrynic acid, chlorthalidone, bendroflumethiazide, and bumetanide) can be performed within 3 min with the detection limits of 0.2-2 microg/mL. The impacts of buffer components including the concentrations of the electrolytes, fluorescence probe, and the organic additives were demonstrated. The method was applied for the detection of diuretics in urine. As an alternative way for the fast analysis of diuretics, this indirect detection method provided the technical support for future microchip performances, in which diuretics may be detected in the microchip by the common LIF detector without derivatization.  相似文献   

19.
Lam MT  Le Chris X 《The Analyst》2002,127(12):1633-1637
A competitive immunoassay using capillary electrophoresis with laser-induced fluorescence was developed for vancomycin. Capillary electrophoresis using a Tris-glycine running buffer provided adequate separation of the antibody-bound from the unbound fluorescent probe (tracer) in less than 4 min. Laser-induced fluorescence polarization (LIFP) provided high sensitivity detection and simultaneous monitoring of fluorescence intensity and polarization. A fluorescence polarization value of 0.30 confirmed the formation of the antibody-tracer complex. Calibration curves showed a working linear range of 2-3 orders of magnitude with a minimum detectable concentration of 0.98 ng mL(-1) (or 1.1 fg vancomycin). Clinical samples obtained from patients undergoing vancomycin treatment were analyzed for vancomycin and the results correlated well with a standard immunoassay based on latex particle detection that was routinely used by a hospital laboratory. Only 1/10 of the reagents were needed as compared with the standard immunoassay.  相似文献   

20.
beta-Galactosidase was incubated for 60 min with the fluorogenic substrate resorufin-beta-D-galactopyranoside, which is converted by the action of the enzyme into resorufin and galactose. A 160 pL aliquot of reaction mixture was analyzed by capillary electrophoresis utilizing laser-induced fluorescence detection. Based on the detection of the resorufin formed, the limit of detection of beta-galactosidase was 1.5 x 10(-15) M or 900 molecules of enzyme in a 1 microL sample.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号