首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
ObjectivesWe validate a 4D strategy tailored for 3 T clinical systems to simultaneously quantify function and infarct size in wild type mice after ischemia/reperfusion, with improved spatial and temporal resolution by comparison to previous published protocols using clinical field MRI systems.MethodsC57BL/6J mice underwent 60 min ischemia/reperfusion (n = 14) or were controls without surgery (n = 6). Twenty-four hours after surgery mice were imaged with gadolinium injection and sacrificed for post-mortem MRI and histology with serum also taken for Troponin I levels. The double ECG- and respiratory-triggered 3D FLASH (Fast Low Angle Shot) gradient echo (GRE) cine sequence had an acquired isotropic resolution of 344 μm, TR/TE of 7.8/2.9 ms and acquisition time 25–35 min. The conventional 2D FLASH cine sequence had the same in-plane resolution of 344 μm, 1 mm slice thickness and TR/TE 11/5.4 ms for an acquisition time of 20–25 min plus 5 min for planning. Left ventricle (LV) and right ventricle (RV) volumes were measured and functional parameters compared 2D to 3D, left to right and for inter and intra observer reproducibility. MRI infarct volume was compared to histology.ResultsFor the function evaluation, the 3D cine outperformed 2D cine for spatial and temporal resolution. Protocol time for the two methods was equivalent (25–35 min). Flow artifacts were reduced (p = 0.008) and epi/endo-cardial delineation showed good intra and interobserver reproducibility. Paired t-test comparing ejection volume left to right showed no significant difference for 3D (p = 0.37), nor 2D (p = 0.30) and correlation slopes of left to right EV were 1.17 (R2 = 0.75) for 2D and 1.05 (R2 = 0.50) for 3D.Quantifiable ‘late gadolinium enhancement’ infarct volume was seen only with the 3D cine and correlated to histology (R2 = 0.89). Left ejection fraction and MRI-measured infarct volume correlated (R2 > 0.3).ConclusionsThe 4D strategy, with contrast injection, was validated in mice for function and infarct quantification from a single scan with minimal slice planning.  相似文献   

2.
PurposeTo determine the clinical value of routine use of thin-section 3D MRI using 3D FSE sequences with a variable flip angle technique for internal derangements of the knee joint at 3 T.Method and MaterialsThirty-four knees in 34 patients suspected of having internal derangements of the knee joint were included. Following standard 2D MRI protocol including sagittal PDWI, T1WI and T2*WI, coronal fat-suppressed PDWI, and axial fat-suppressed PDWI with 3-4 mm thicknesses, fat-suppressed and water-excitation PDWI using 3D FSE sequences with a variable flip angle technique with 0.6 mm thickness were obtained in coronal plane and the three major planes with 1 mm thickness (3D MRI) was reformatted. The standard 2D MRI protocol and reformatted 3D MRI protocol (three sagittal 2D sequence images plus 3D MRI) were independently analyzed by two radiologists concerning presence or absence of lesions in the menisci, cartilage, and ligament. Interobserver agreements in both the MRI protocols were assessed by weighted-kappa coefficients. Regarding diagnostic accuracy, areas under the receiver operating characteristic curves (Az values) of both the MRI protocols were compared.ResultsThirty-eight meniscal lesions, 39 cartilage lesions, and 20 ligamentous lesions were surgically detected. Excellent interobserver agreements (kappa = 0.91–0.98) were seen in both the MRI protocols, with a slightly better tendency in the reformatted 3D MRI protocol. Average Az values in detection of the meniscal, cartilage, and ligamentous lesions were significantly higher in the reformatted 3D MRI protocol than in the standard 2D MRI protocol (p < 0.01 or p < 0.001).ConclusionRoutine use of reformatted thin-section 3D MRI using 3D FSE sequences with a variable flip angle technique may improve diagnostic accuracy and confidence in detection of internal derangements of the knee joint.  相似文献   

3.
PurposeTo present a method that uses a novel free-running self-gated acquisition to achieve isotropic resolution in whole heart 3D Cartesian cardiac CINE MRI.Material and methods3D cardiac CINE MRI using navigator gating results in long acquisition times. Recently, several frameworks based on self-gated non-Cartesian trajectories have been proposed to accelerate this acquisition. However, non-Cartesian reconstructions are computationally expensive due to gridding, particularly in 3D. In this work, we propose a novel highly efficient self-gated Cartesian approach for 3D cardiac CINE MRI. Acquisition is performed using CArtesian trajectory with Spiral PRofile ordering and Tiny golden angle step for eddy current reduction (so called here CASPR-Tiger). Data is acquired continuously under free breathing (retrospective ECG gating, no preparation pulses interruption) for 4–5 min and 4D whole-heart volumes (3D + cardiac phases) with isotropic spatial resolution are reconstructed from all available data using a soft gating technique combined with temporal total variation (TV) constrained iterative SENSE reconstruction.ResultsFor data acquired on eight healthy subjects and three patients, the reconstructed images using the proposed method had good contrast and spatio-temporal variations, correctly recovering diastolic and systolic cardiac phases. Non-significant differences (P > 0.05) were observed in cardiac functional measurements obtained with proposed 3D approach and gold standard 2D multi-slice breath-hold acquisition.ConclusionThe proposed approach enables isotropic 3D whole heart Cartesian cardiac CINE MRI in 4 to 5 min free breathing acquisition.  相似文献   

4.
PurposeTo implement a fast (~ 15 min) MRI protocol for carotid plaque screening using 3D multi-contrast MRI sequences without contrast agent on a 3 Tesla MRI scanner.Materials and methods7 healthy volunteers and 25 patients with clinically confirmed transient ischemic attack or suspected cerebrovascular ischemia were included in this study. The proposed protocol, including 3D T1-weighted and T2-weighted SPACE (variable-flip-angle 3D turbo spin echo), and T1-weighted magnetization prepared rapid acquisition gradient echo (MPRAGE) was performed first and was followed by 2D T1-weighted and T2-weighted turbo spin echo, and post-contrast T1-weighted SPACE sequences. Image quality, number of plaques, and vessel wall thicknesses measured at the intersection of the plaques were evaluated and compared between sequences.ResultsAverage examination time of the proposed protocol was 14.6 min. The average image quality scores of 3D T1-weighted, T2-weighted SPACE, and T1-weighted magnetization prepared rapid acquisition gradient echo were 3.69, 3.75, and 3.48, respectively. There was no significant difference in detecting the number of plaques and vulnerable plaques using pre-contrast 3D images with or without post-contrast T1-weighted SPACE. The 3D SPACE and 2D turbo spin echo sequences had excellent agreement (R = 0.96 for T1-weighted and 0.98 for T2-weighted, p < 0.001) regarding vessel wall thickness measurements.ConclusionThe proposed protocol demonstrated the feasibility of attaining carotid plaque screening within a 15-minute scan, which provided sufficient anatomical coverage and critical diagnostic information. This protocol offers the potential for rapid and reliable screening for carotid plaques without contrast agent.  相似文献   

5.
PurposeTo develop and evaluate a free breathing respiratory self-gated isotropic resolution technique for left ventricular (LV) volume measurements.MethodsA 3D radial trajectory with double golden-angle ordering was used for free-running data acquisition during free breathing in 9 healthy volunteers. A respiratory self-gating signal was extracted from the center of k-space and used with the electrocardiogram to bin all data into 3 respiratory and 25 cardiac phases. 3D image volumes were reconstructed and the LV endocardial border was segmented. LV volume measurements and reproducibility from 3D free breathing cine were compared to conventional 2D breath-held cine.ResultsNo difference was found between 3D free breathing cine and 2D breath-held cine with regards to LV ejection fraction, stroke volume, end-systolic volume and end-diastolic volume (P < 0.05 for all). The test-retest differences did not differ between 3D free breathing cine and 2D breath-held cine (P < 0.05 for all).Conclusion3D free breathing cine and conventional 2D breath-held cine showed similar values and test-retest repeatability for LV volumes in healthy volunteers. 3D free breathing cine enabled retrospective sorting and arbitrary angulation of isotropic data, and could correctly measure LV volumes during free breathing acquisition.  相似文献   

6.
BackgroundThe left ventricle (LV) wall thickness is an important and routinely measured cardiologic parameter. Here we introduce three-dimensional (3D) mapping of LV wall thickness and function using a self-gated magnetic resonance (MR) sequence for ultra-high-field 11.7-T MR cine imaging of mouse hearts.Methods and resultsSix male C57BL/6-j mice were subjected to 11.7-T MR imaging (MRI). Three standard views—short axis, long axis four-chamber, and long axis two-chamber—and eight consecutive short axis scans from the apex to base were performed for each mouse. The resulting 11 self-gated cine images were used for fast low-angle shot analysis with a navigator echo over an observation period of approximately 35 min. The right ventricle (RV) and LV were identified in the short axis and four-chamber views. On 3D color-coded maps, the interventricular septum wall (diastole: 0.94 ± 0.05 mm, systole: 1.20 ± 0.09 mm) and LV free wall (diastole: 1.07 ± 0.15 mm, systole: 1.79 ± 0.11 mm) thicknesses were measured.ConclusionThis 3D wall thickness mapping technique can be used to observe regional wall thickness at the end-diastole and end-systole. Self-gated cine imaging based on ultra-high-field MRI can be used to accurately and easily measure cardiac function and wall thickness in normal mouse hearts. As in the preclinical study, this versatile and simple method will be clinically useful for the high-field-MRI evaluation of cardiac function and wall thickness.  相似文献   

7.
PurposeTo investigate the in-vivo precision and clinical feasibility of 3D-QALAS - a novel method for simultaneous three-dimensional myocardial T1- and T2-mapping.MethodsTen healthy subjects and 23 patients with different cardiac pathologies underwent cardiovascular 3 T MRI examinations including 3D-QALAS, MOLLI and T2-GraSE acquisitions. Precision was investigated in the healthy subjects between independent scans, between dependent scans and as standard deviation of consecutive scans. Clinical feasibility of 3D-QALAS was investigated for native and contrast enhanced myocardium in patients. Data were analyzed using mean value and 95% confidence interval, Pearson correlation, Paired t-tests, intraclass correlation and Bland-Altman analysis.ResultsAverage myocardial relaxation time values and SD from eight repeated acquisitions within the group of healthy subjects were 1178 ± 18.5 ms (1.6%) for T1 with 3D-QALAS, 52.7 ± 1.2 ms (2.3%) for T2 with 3D-QALAS, 1145 ± 10.0 ms (0.9%) for T1 with MOLLI and 49.2 ± 0.8 ms (1.6%) for T2 with GraSE.Myocardial T1 and T2 relaxation times obtained with 3D-QALAS correlated very well with reference methods; MOLLI for T1 (r = 0.994) and T2-GraSE for T2 (r = 0.818) in the 23 patients. Average native/post-contrast myocardial T1 values from the patients were 1166.2 ms/411.8 ms for 3D-QALAS and 1174.4 ms/438.9 ms for MOLLI. Average native myocardial T2 values from the patients were 53.2 ms for 3D-QALAS and 54.4 ms for T2-GraSE.ConclusionsRepeated independent and dependent scans together with the intra-scan repeatability, demonstrated all a very good precision for the 3D-QALAS method in healthy volunteers. This study shows that 3D T1 and T2 mapping in the left ventricle is feasible in one breath hold for patients with different cardiac pathologies using 3D-QALAS.  相似文献   

8.
PurposeQuantification of myocardial oxygenation (MO) in heart failure (HF) has been less than satisfactory. This has necessitated the use of invasive techniques to measure MO directly or to determine the oxygen demand during exercise using the cardiopulmonary exercise (CPX) test. We propose a new quantification method for MO using blood-oxygen-level-dependent (BOLD) myocardial T2* magnetic resonance imaging (M-T2* MRI), and investigate its correlation with CPX results.MethodsThirty patients with refractory HF who underwent cardiac MRI and CPX test for heart transplantation, and 24 healthy, age-matched volunteers as controls were enrolled. M-T2* imaging was performed using a 3-Tesla and multi-echo gradient-echo sequence. M-T2* was calculated by fitting the signal intensity data for the mid-left ventricular septum to a decay curve. M-T2* was measured under room-air (T2*-air) and after inhalation of oxygen for 10 min at a flow rate of 10 L/min (T2*-oxy). MO was defined as the difference between the two values (ΔT2*). Changes in M-T2* at the two conditions and ΔT2* between the two groups were compared. Correlation between ΔT2* and CPX results was analyzed using the Pearson coefficient.ResultsT2*-oxy was significantly greater than T2*-air in patients with HF (29.9 ± 7.3 ms vs. 26.7 ± 6.0 ms, p < 0.001), whereas no such difference was observed in controls (25.5 ± 4.0 ms vs. 25.4 ± 4.4 ms). ΔT2* was significantly greater for patients with HF than for controls (3.2 ± 4.5 ms vs. -0.1 ± 1.3 ms, p < 0.001). A significant correlation between ΔT2* and CPX results (peak VO2, r =  0.46, p < 0.05; O2 pulse, r =  0.54, p < 0.005) was observed.ConclusionΔT2* is increased T2*-oxy is greater in patients with HF, and is correlated with oxygen metabolism during exercise as measured by the CPX test. Hence, ΔT2* can be used as a surrogate marker of MO instead of CPX test.  相似文献   

9.
PurposeTo quantify the differential plasma flow- (Fp-) and permeability surface area product per unit mass of tissue- (PS-) weighting in forward volumetric transfer constant (Ktrans) estimates by using a low molecular (Gd-DTPA) versus high molecular (Gadomer) weight contrast agent in dynamic contrast enhanced (DCE) MRI.Materials and methodsDCE MRI was performed using a 7T animal scanner in 14 C57BL/6J mice syngeneic for TRAMP tumors, by administering Gd-DTPA (0.9 kD) in eight mice and Gadomer (35 kD) in the remainder. The acquisition time was 10 min with a sampling rate of one image every 2 s. Pharmacokinetic modeling was performed to obtain Ktrans by using Extended Tofts model (ETM). In addition, the adiabatic approximation to the tissue homogeneity (AATH) model was employed to obtain the relative contributions of Fp and PS.ResultsThe Ktrans values derived from DCE-MRI with Gd-DTPA showed significant correlations with both PS (r2 = 0.64, p = 0.009) and Fp (r2 = 0.57, p = 0.016), whereas those with Gadomer were found only significantly correlated with PS (r2 = 0.96, p = 0.0003) but not with Fp (r2 = 0.34, p = 0.111). A voxel-based analysis showed that Ktrans approximated PS (< 30% difference) in 78.3% of perfused tumor volume for Gadomer, but only 37.3% for Gd-DTPA.ConclusionsThe differential contributions of Fp and PS in estimating Ktrans values vary with the molecular weight of the contrast agent used. The macromolecular contrast agent resulted in Ktrans values that were much less dependent on flow. These findings support the use of macromolecular contrast agents for estimating tumor vessel permeability with DCE-MRI.  相似文献   

10.
PurposeTo demonstrate the clinical feasibility of a new non-Cartesian cylindrically-distributed spiral 3D pseudo-continuous arterial spin labeling (pCASL) magnetic resonance imaging (MRI) pulse sequence in pediatric patients in quantifying cerebral blood flow (CBF) response to an acetazolamide (ACZ) vasodilator challenge.Materials and methodsMRI exams were performed on two 3 Tesla Philips Ingenia systems using 32 channel head coil arrays. After local institutional review board approval, the 3D spiral-based pCASL technique was added to a standard brain MRI exam and evaluated in 13 pediatric patients (average age: 11.7 ± 6.4 years, range: 1.4–22.2 years). All patients were administered ACZ for clinically indicated reasons. Quantitative whole-brain CBF measurements were computed pre- and post-ACZ to assess cerebrovascular reserve.Results3D spiral pCASL data were successfully reconstructed in all 13 cases. In 11 patients, CBF increased 2.8% to 93.2% after administration of ACZ. In the two remaining patients, CBF decreased by 2.4 to 6.0% after ACZ. The group average change in CBF due to ACZ was approximately 25.0% and individual changes were statistically significant (p < 0.01) in all patients using a paired t-test analysis. CBF perfusion data were diagnostically useful in supporting conventional MR angiography and clinical findings.Conclusion3D cylindrically-distributed spiral pCASL MRI provides a robust approach to assess cerebral blood flow and reserve in pediatric patients.  相似文献   

11.
PurposeTo investigate right ventricular (RV) strain in patients without identified cardiac pathology using cardiac magnetic resonance tissue tracking (CMR TT).MethodsA total of 50 consecutive patients with no identified cardiac pathology were analyzed. RV longitudinal and circumferential strain was assessed by CMR TT. The age range was 4–81 years with a median of 32 years (interquartile range, 15 to 56 years).ResultsAnalysis time per patient was < 5 min. The peak longitudinal strain (Ell) was − 22.11 ± 3.51%. The peak circumferential strains (Ecc) for global, basal, mid-cavity and apical segments were as follows: − 11.69 ± 2.25%, − 11.00 ± 2.45%, − 11.17 ± 3.36%, − 12.90 ± 3.34%. There were significant gender differences in peak Ecc at the base (P = 0.04) and the mid-cavity (P = 0.03) with greater deformation in females than in males. On Bland-Altman analysis, peak Ell (mean bias, 0.22 ± 1.67; 95% CI − 3.05 to 3.49) and mid-cavity Ecc (mean bias, 0.036 ± 1.75; 95% CI, − 3.39 to 3.47) had the best intra-observer agreement and inter-observer agreement, respectively.ConclusionsRV longitudinal and circumferential strains can be quickly assessed with good intra-observer and inter-observer variability using TT.  相似文献   

12.
PurposeTo investigate the value of use of intravoxel incoherent motion diffusion-weighted imaging (IVIM-DWI) as an adjunct to dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) to distinguish benign from malignant breast lesions.Materials and methodsRetrospective analysis of data pertaining to 117 patients with breast lesions who underwent DCE-MRI and IVIM-DWI examination with 3.0 T MRI was conducted. A total of 128 lesions were pathologically confirmed (47 benign and 81 malignant). Between-group differences in DCE-MRI parameters (Morphology, enhancement pattern, maximum slope of increase (MSI) and time–signal curve (TIC) type) and IVIM-DWI parameters (f value, D value and D* value) were assessed. Multivariate logistic regression was performed to identify variables that distinguished benign from malignant breast lesions. The diagnostic performance of DCE-MRI and DCE-MRI plus IVIM-DWI, to distinguish benign from malignant breast lesions, was evaluated using pathology results as the gold standard.ResultsLesion morphology, MSI, and TIC type (P < 0.05), but not the enhancement pattern (P > 0.05), were significantly different between the benign and malignant groups. The f (8.53 ± 2.14) and D* (7.64 ± 2.07) values in the malignant group were significantly higher than those in the benign group (7.68 ± 1.97 and 6.83 ± 2.13, respectively), while the D value (0.99 ± 0.22) was significantly lower than that (1.34 ± 0.17) in the benign group (P < 0.05 for all). On logistic regression analysis, the sensitivity, specificity and accuracy of DCE-MRI were 90.1%, 70.2% and 82.8% respectively; the corresponding figures for the combination of IVIM-DWI and DCE-MRI were 88.8%, 85.1%, and 87.5%respectively.ConclusionIVIM-DWI method as an adjunct to DCE-MRI can improve the specificity and accuracy in differential diagnosis of benign and malignant lesions of breast.  相似文献   

13.
IntroductionTechnological developments have increased the ease of performing perfusion MRI by arterial spin labeling (ASL) in clinical settings. The objective of this study was to evaluate the effects of radiotherapy on extra-axial brain tumors by using MR perfusion images obtained using the pseudo-continuous arterial spin labeling (pcASL) method.Materials and MethodsSix consecutive patients (nine lesions) with extra-axial brain tumors treated only with radiotherapy were enrolled in this study. MR examinations, including pcASL imaging, were performed before and after radiotherapy. Cerebral blood flow, maximum tumor blood flow (mTBF), tumor volume and the ratio of signal enhancement by contrast material (enhancement ratio) were evaluated in serial examinations during the course of radiotherapy. Both the percentage change in mTBF (mTBF ratio) and the percentage change in volume (volume ratio) were calculated using values obtained before and after radiotherapy. The correlation between the volume ratio and the mTBF ratio was assessed using linear regression analysis and Spearman’s rank correlation coefficient (rs).ResultsA strong correlation was demonstrated between the tumor volume ratio and the mTBF ratio before and after radiotherapy (rs= 0.93, P< .01). However, no significant correlation was identified between changes in enhancement and volume ratio (rs= 0.20) or between changes in enhancement and mTBF ratio (rs= 0.30) before and after radiotherapy.ConclusionThe mTBF measured using pcASL may serve as an additive index for tumor volume when determining tumor response to radiotherapy even in the absence of contrast material.  相似文献   

14.
PurposeTo introduce a simple analytical formula for estimating T2 from a single Double-Echo in Steady-State (DESS) scan.MethodsExtended Phase Graph (EPG) modeling was used to develop a straightforward linear approximation of the relationship between the two DESS signals, enabling accurate T2 estimation from one DESS scan. Simulations were performed to demonstrate cancellation of different echo pathways to validate this simple model. The resulting analytic formula was compared to previous methods for T2 estimation using DESS and fast spin-echo scans in agar phantoms and knee cartilage in three volunteers and three patients. The DESS approach allows 3D (256 × 256 × 44) T2-mapping with fat suppression in scan times of 3–4 min.ResultsThe simulations demonstrated that the model approximates the true signal very well. If the T1 is within 20% of the assumed T1, the T2 estimation error was shown to be less than 5% for typical scans. The inherent residual error in the model was demonstrated to be small both due to signal decay and opposing signal contributions. The estimated T2 from the linear relationship agrees well with reference scans, both for the phantoms and in vivo. The method resulted in less underestimation of T2 than previous single-scan approaches, with processing times 60 times faster than using a numerical fit.ConclusionA simplified relationship between the two DESS signals allows for rapid 3D T2 quantification with DESS that is accurate, yet also simple. The simplicity of the method allows for immediate T2 estimation in cartilage during the MRI examination.  相似文献   

15.
PurposeTo evaluate the biophysical processes that generate specific T2 values and their relationship to specific cerebrospinal fluid (CSF) content.Materials and methodsCSF T2s were measured ex vivo (14.1 T) from isolated CSF collected from human, rat and non-human primate. CSF T2s were also measured in vivo at different field strength in human (3 and 7 T) and rodent (1, 4.7, 9,4 and 11.7 T) using different pulse sequences. Then, relaxivities of CSF constituents were measured, in vitro, to determine the major molecule responsible for shortening CSF T2 (2 s) compared to saline T2 (3 s). The impact of this major molecule on CSF T2 was then validated in rodent, in vivo, by the simultaneous measurement of the major molecule concentration and CSF T2.ResultsEx vivo CSF T2 was about 2.0 s at 14.1 T for all species. In vivo human CSF T2 approached ex vivo values at 3 T (2.0 s) but was significantly shorter at 7 T (0.9 s). In vivo rodent CSF T2 decreased with increasing magnetic field and T2 values similar to the in vitro ones were reached at 1 T (1.6 s). Glucose had the largest contribution of shortening CSF T2 in vitro. This result was validated in rodent in vivo, showing that an acute change in CSF glucose by infusion of glucose into the blood, can be monitored via changes in CSF T2 values.ConclusionThis study opens the possibility of monitoring glucose regulation of CSF at the resolution of MRI by quantitating T2.  相似文献   

16.
ObjectivesTo evaluate the safety of ultrasound-guided high-intensity focused ultrasound (HIFU) ablation for patients with diffuse adenomyosis.MethodsThis was a retrospective cohort study. The data was collected from 417 symptomatic adenomyosis patients who underwent ultrasound-guided HIFU between January 2012 and December 2015 at 1st Affiliated Hospital of Chongqing Medical University, Chongqing, China. Among them were 260 patients with diffuse adenomyosis (Group D) and 157 patients with focal adenomyosis (Group F). All patients underwent contrast-enhanced magnetic resonance imaging (MRI) one week before and the day after HIFU treatment. Successful treatment with HIFU was measured by the non-perfused volume ratio (NPVR). Intraprocedural and postprocedural adverse effects and complications were recorded to assess the safety of the procedure. Patients were followed-up for three months post-treatment. Complications were given a grade A through F according to the SIR Standards.ResultsAll patients successfully completed the procedure, non-perfused regions appeared in 415 (99.5%) patients. The non-perfused volume ratio (NPVR) of Group D was significantly lower than that of Group F (P < 0.05). During the procedure, the odds ratio of skin-burning pain was 1.7 (OR = 1.617, 95% CI: 1.103–2.532), when comparing Group D with Group F, while the odds ratio of inguinal pain was equal to 2.0 (OR = 2.038, 95% CI: 1.161–3.580), when Group F was compared to Group D. 97 patients (23.3%) received nominal therapy due to complications ([Society of interventional radiology, SIR]-B grade), among them, there were 62 cases (23.8%) in Group D and 35 cases (22.3%) in Group F. No significant difference was found between the two groups (P > 0.05) and neither of the reported complications of SIR-C-SIR-F occurred within the two groups.ConclusionsBased on our results, ultrasound-guided HIFU is safe for the treatment of diffuse adenomyosis, and controlling the ablation zone is crucial to ensure patients’ safety.  相似文献   

17.
PurposeThe detection of small parenchymal hepatic lesions identified by preoperative imaging remains a challenge for traditional pathologic methods in large specimens. We developed a magnetic resonance imaging (MRI) compatible localization device for imaging of surgical specimens aimed to improve identification and localization of hepatic lesions ex vivo.Materials and methodsThe device consists of two stationary and one removable MR-visible grids lined with silicone gel, creating an orthogonal 3D matrix for lesion localization. To test the device, five specimens of swine liver with a random number of lesions created by microwave ablation were imaged on a 3 T MR scanner. Two readers independently evaluated lesion coordinates and size, which were then correlated with sectioning guided by MR imaging.ResultsAll lesions (n = 38) were detected at/very close to the expected localization. Inter-reader agreement of lesion localization was almost perfect (0.92). The lesion size estimated by MRI matched macroscopic lesion size in cut specimen (± 2 mm) in 34 and 35, respectively, out of 38 lesions.ConclusionUse of this MR compatible device for ex vivo imaging proved feasible for detection and three-dimensional localization of liver lesions, and has potential to play an important role in the ex vivo examination of surgical specimens in which pathologic correlation is clinically important.  相似文献   

18.
AimTo assess the value of callosal morphological and microstructural integrity in assessing different cognitive domains, fatigue and depression in mildly disabled multiple sclerosis (MS) patients.Materials and methodsWe assessed 29 mildly disabled MS patients and 15 healthy controls using 3T magnetic resonance images (T1-weighted, FLAIR and DTI) and neuropsychological tests assessing different cognitive functions, depression and fatigue. We compared the added value of morphological measures (corpus callosum area corrected for total intracranial volume, index, circularity and the more detailed thickness profile) and diffusion features (fractional anisotropy and mean diffusivity) in multilinear models including standard clinical and whole-brain parameters in assessing neuropsychological scores.ResultsEven in mildly disabled MS patients, a significant reduction of the corpus callosum (p < 0.001) was observed in comparison to healthy controls. Callosal area, index and circularity were significantly (p < 0.002) related to whole-brain white matter volume, T2 lesion load and deep grey matter volume, but not with cortical grey matter.The combination of commonly used imaging and clinical parameters explained between 7% (Fatigue) and 50% (processing speed, verbal memory) of the adjusted variance. Inclusion of the mean diffusivity increased the adjusted R2 significantly to 69% (p = 0.004) and 71% (p = 0.002) for visuospatial and verbal memory respectively.ConclusionOur results show that callosal features may be used as an alternative to measuring whole-brain volumes. Furthermore, the microstructural integrity of the corpus callosum can help to predict an MS patient's memory performance.  相似文献   

19.
PurposeTo determine magnetic resonance elastography (MRE)-derived stiffness of pancreas in healthy volunteers with emphasis on: 1) short term and midterm repeatability; and 2) variance as a function of age.MethodsPancreatic MRE was performed on 22 healthy volunteers (age range:20–64 years) in a 3 T–scanner. For evaluation of reproducibility of stiffness estimates, the scans were repeated per volunteer on the same day (short term) and one month apart (midterm). MRE wave images were analyzed using 3D inversion to estimate the stiffness of overall pancreas and different anatomic regions (i.e., head, neck, body, and tail). Concordance and Spearman correlation tests were performed to determine reproducibility of stiffness measurements and relationship to age.ResultsA strong concordance correlation (ρc = 0.99; p-value < 0.001) was found between short term and midterm repeatability pancreatic stiffness measurements. Additionally, the pancreatic stiffness significantly increased with age with good Spearman correlation coefficient (all ρ > 0.81; p < 0.001). The older age group (> 45 yrs) had significantly higher stiffness compared to the younger group (≤ 45 yrs) (p < 0.001). No significant difference (p > 0.05) in stiffness measurements was observed between different anatomical regions of pancreas, except neck stiffness was slightly lower (p < 0.012) compared to head and overall pancreas at month 1.ConclusionMRE-derived pancreatic stiffness measurements are highly reproducible in the short and midterm and increase linearly with age in healthy volunteers. Further studies are needed to examine these effects in patients with various pancreatic diseases to understand potential clinical applications.  相似文献   

20.
ObjectivesTo evaluate the diagnostic performance of a new three-dimensional T1-weighted turbo-spin-echo sequence (3D T1-w TSE) compared to 3D contrast-enhanced angiography (CE-MRA) for stenosis measurement and compared to 2D T1-w TSE for intra-plaque hemorrhage (IPH) detection.MethodsEighty three patients underwent carotid MRI, using a new elliptic-centric phase encoding T1-weighted 3D TSE sequence in addition to the clinical protocol.Two observers evaluated image quality, presence of flow artifacts, and presence of intra-plaque hemorrhage, and computed the NASCET degree of stenosis for CE-MRA and for the new sequence. Inter-observer agreement and correlation between 3D TSE and CE-MRA for NASCET stenosis was estimated using Cohen's kappa, and correlation using linear regression and Bland-Altman plots.Histology was performed on endarterectomy samples for 18 patients. Sensitivity and specificity of 2D and 3D TSE for IPH diagnosis were computed.Results3D TSE showed better image quality than 2D TSE (p < 0.05). Interobserver agreement was good (kappa  0.86). Correlation between 3D TSE and CE-MRA was excellent (R = 0.95) for NASCET stenosis. Sensitivity and specificity for IPH diagnosis was 50% and 100% for 2D TSE and 100% and 83% for the 3D TSE.ConclusionsThe new 3D T1-w TSE allows both reliable measures of carotid stenosis, with a slight overestimation compared to CE-MRA (5%), and improved IPH identification, compared to 2D TSE.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号