首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 846 毫秒
1.
《Ultrasonics sonochemistry》2014,21(6):2092-2098
This study showed that temperature influences the rate of separation of fat from natural whole milk during application of ultrasonic standing waves. In this study, natural whole milk was sonicated at 600 kHz (583 W/L) or 1 MHz (311 W/L) with a starting bulk temperature of 5, 25, or 40 °C. Comparisons on separation efficiency were performed with and without sonication. Sonication using 1 MHz for 5 min at 25 °C was shown to be more effective for fat separation than the other conditions tested with and without ultrasound, resulting in a relative change from 3.5 ± 0.06% (w/v) fat initially, of −52.3 ± 2.3% (reduction to 1.6 ± 0.07% (w/v) fat) in the skimmed milk layer and 184.8 ± 33.2% (increase to 9.9 ± 1.0% (w/v) fat) in the top layer, at an average skimming rate of ∼5 g fat/min. A shift in the volume weighted mean diameter (D[4,3]) of the milk samples obtained from the top and bottom of between 8% and 10% relative to an initial sample D[4,3] value of 4.5 ± 0.06 μm was also achieved under these conditions. In general, faster fat separation was seen in natural milk when natural creaming occurred at room temperature and this separation trend was enhanced after the application of high frequency ultrasound.  相似文献   

2.
The ultrasonic fractionation of milk fat in whole milk to fractions with distinct particle size distributions was demonstrated using a stage-based ultrasound-enhanced gravity separation protocol. Firstly, a single stage ultrasound gravity separation was characterised after various sonication durations (5–20 min) with a mass balance, where defined volume partitions were removed across the height of the separation vessel to determine the fat content and size distribution of fat droplets. Subsequent trials using ultrasound-enhanced gravity separation were carried out in three consecutive stages. Each stage consisted of 5 min sonication, with single and dual transducer configurations at 1 MHz and 2 MHz, followed by aliquot collection for particle size characterisation of the formed layers located at the bottom and top of the vessel. After each sonication stage, gentle removal of the separated fat layer located at the top was performed.Results indicated that ultrasound promoted the formation of a gradient of vertically increasing fat concentration and particle size across the height of the separation vessel, which became more pronounced with extended sonication time. Ultrasound-enhanced fractionation provided fat enriched fractions located at the top of the vessel of up to 13 ± 1% (w/v) with larger globules present in the particle size distributions. In contrast, semi-skim milk fractions located at the bottom of the vessel as low as 1.2 ± 0.01% (w/v) could be produced, containing proportionally smaller sized fat globules. Particle size differentiation was enhanced at higher ultrasound energy input (up to 347 W/L). In particular, dual transducer after three-stage operation at maximum energy input provided highest mean particle size differentiation with up to 0.9 μm reduction in the semi-skim fractions. Higher frequency ultrasound at 2 MHz was more effective in manipulating smaller sized fat globules retained in the later stages of skimming than 1 MHz. While 2 MHz ultrasound removed 59 ± 2% of the fat contained in the initial sample, only 47 ± 2% was removed with 1 MHz after 3 ultrasound-assisted fractionation stages.  相似文献   

3.
PurposeTo investigate right ventricular (RV) strain in patients without identified cardiac pathology using cardiac magnetic resonance tissue tracking (CMR TT).MethodsA total of 50 consecutive patients with no identified cardiac pathology were analyzed. RV longitudinal and circumferential strain was assessed by CMR TT. The age range was 4–81 years with a median of 32 years (interquartile range, 15 to 56 years).ResultsAnalysis time per patient was < 5 min. The peak longitudinal strain (Ell) was − 22.11 ± 3.51%. The peak circumferential strains (Ecc) for global, basal, mid-cavity and apical segments were as follows: − 11.69 ± 2.25%, − 11.00 ± 2.45%, − 11.17 ± 3.36%, − 12.90 ± 3.34%. There were significant gender differences in peak Ecc at the base (P = 0.04) and the mid-cavity (P = 0.03) with greater deformation in females than in males. On Bland-Altman analysis, peak Ell (mean bias, 0.22 ± 1.67; 95% CI − 3.05 to 3.49) and mid-cavity Ecc (mean bias, 0.036 ± 1.75; 95% CI, − 3.39 to 3.47) had the best intra-observer agreement and inter-observer agreement, respectively.ConclusionsRV longitudinal and circumferential strains can be quickly assessed with good intra-observer and inter-observer variability using TT.  相似文献   

4.
The objective of present study was to develop a nanoemulsion formulation of agomelatine (BCS class II drug) for the solubility enhancement. Capmul MCM, Tween 80 and PEG-400 were selected as oil, surfactant and co-surfactant respectively. The high energy ultrasonication method was used for the preparation of nanoemulsion. Three-factor three-level central composite design was employed to get the best formulation. The independent variables selected for the optimization were % oil, %Smix and sonication time (second). Based on the constraints applied to independent and dependent variables, the optimized formulation was selected with 2% oil, 10% Smix and 45 s sonication time. The experimental values for dependent variables such as hydrodynamic diameter (nm), % transmittance and % CDR were found to be 73.72 ± 2.53 nm, 98.2 ± 0.42%, 84.71 ± 4.05% respectively. TEM and AFM−assisted morphological characterization of optimized Ago-NE was done and it was found with a spherical shape. The PDI, Zeta potential and the refractive index of optimized Ago-NE were found to be 0.137 ± 0.016, −7.40 ± 0.12 mV and 1.423 ± 0.045 respectively. The viscosity, pH and drug content of optimized Ago-NE were found as 25.12 ± 0.67 cP, 6.4 ± 0.17 and 97.83 ± 1.03% respectively. The ex-vivo permeation profile of optimized Ago-NE and agomelatine suspension through goat nasal mucosa were compared till 12 h and % cumulative drug permeated was found to be 90% and 40% respectively. The higher drug permeation profile of optimized Ago-NE confirmed that the solubility of agomelatine has been improved.  相似文献   

5.
Diamond like carbon (DLC) coatings were deposited on silicon(1 1 1) substrates by microwave electron cyclotron resonance (ECR) plasma CVD process using a plasma of Ar and CH4 gases under the influence of DC self bias generated on the substrates by application of RF (13.56 MHz) power. DLC coatings were deposited under the varying influence of DC bias (−60 V to −150 V) on the Si substrates. Deposited films were analyzed by different techniques like: X-ray photoelectron spectroscopy (XPS), spectroscopic ellipsometry (SE), atomic force microscopy (AFM), Hardness and elastic modulus determination technique, Raman spectroscopy, scanning electron microscopy (SEM) and contact angle measurement. The results indicate that the film grown at −100 V bias has optimised properties like high sp3/sp2 ratio of carbon bonding, high refractive index (2.26–2.17) over wide spectral range 400–1200 nm, low roughness of 0.8 nm, high contact angle (80°) compared to the films deposited at other bias voltages (−60 V and −150 V). The results are consistent with each other and find august explanation under the subplantation model for DLC growth.  相似文献   

6.
BackgroundAssessment of muscle atrophy and fatty degeneration in brachial plexus injury (BPI) could yield valuable insight into pathophysiology and could be used to predict clinical outcome. The objective of this study was to quantify and relate fat percentage and cross-sectional area (CSA) of the biceps to range of motion and muscle force of traumatic brachial plexus injury (BPI) patients.MethodsT1-weighted TSE sequence and three-point Dixon images of the affected and non-affected biceps brachii were acquired on a 3 Tesla magnetic resonance scanner to determine the fat percentage, total and contractile CSA of 20 adult BPI patients. Regions of interest were drawn by two independent investigators to determine the inter-observer reliability. Paired Students' t-test and multivariate analysis were used to relate fat percentage, total and contractile CSA to active flexion and biceps muscle force.ResultsThe mean fat percentage 12 ± 5.1% of affected biceps was higher than 6 ± 1.0% of the non-affected biceps (p < 0.001). The mean contractile CSA 8.1 ± 5.1 cm2 of the affected biceps was lower than 19.4 ± 4.9 cm2 of the non-affected biceps (p < 0.001). The inter-observer reliability was excellent (ICC 0.82 to 0.96). The contractile CSA contributed most to the reduction in active flexion and muscle force.ConclusionQuantitative measurement of fat percentage, total and contractile CSA using three-point Dixon sequences provides an excellent reliability and relates with active flexion and muscle force in BPI.  相似文献   

7.
PurposeTo obtain water and lipid diffusion-weighted images (DWIs) simultaneously, we devised a novel method utilizing chemical shift displacement-based separation of lipid tissue (SPLIT) imaging.Materials and methodsSingle-shot diffusion echo-planar imaging without fat suppression was used and the imaging parameters were optimized to separate water and lipid DWIs by chemical shift displacement of the lipid signals along the phase-encoding direction. Using the optimized conditions, transverse DWIs at the maximum diameter of the right calf were scanned with multiple b-values in five healthy subjects. Then, apparent diffusion coefficients (ADCs) were calculated in the tibialis anterior muscle (TA), tibialis bone marrow (TB), and subcutaneous fat (SF), as well as restricted and perfusion-related diffusion coefficients (D and D*, respectively) and the fraction of the perfusion-related diffusion component (F) for TA.ResultsWater and lipid DWIs were separated adequately. The mean ADCs of the TA, TB, and SF were 1.56 ± 0.03 mm2/s, 0.01 ± 0.01 mm2/s, and 0.06 ± 0.02 mm2/s, respectively. The mean D*, D, and F of the TA were 13.7 ± 4.3 mm2/s, 1.48 ± 0.05 mm2/s, and 4.3 ± 1.6%, respectively.ConclusionSPLIT imaging makes it possible to simply and simultaneously obtain water and lipid DWIs without special pulse sequence and increases the amount of diffusion information of water and lipid tissue.  相似文献   

8.
We present a uniplanar coplanar-waveguide 3-dB tandem coupler operating at V-band frequencies. The uniplanar structure is monolithically fabricated by using two-section parallel-coupled lines and air-bridge crossovers replacing the conventional multilayer or bonded structures. Due to an optimized tandem structure and non-bonded crossovers minimizing the parasitic components, a maximum coupling of 2.5 dB is measured at 62 GHz with a 2 dB bandwidth of 83%, while a high directivity factor of 33 dB is simultaneously obtained at 58–62 GHz. Over the entire design frequency range of 30–90 GHz, we achieve good phase unbalance of 90 ± 6.0°, as well as return loss and isolation lower than −23 and −16 dB, respectively.  相似文献   

9.
《Ultrasonics sonochemistry》2014,21(3):1083-1089
This paper illustrates the application of ultrasound in a dairy waste water treatment for the removal of fat using enzyme as a catalyst. Lipase Z was used to perform the enzymatic pre-hydrolysis of a synthetic dairy wastewater containing around 2000 mg/L of fat content coupled with ultrasound irradiation. Different process parameters like effect of enzyme loading, temperature, ultrasound power, frequency, duty cycle and speed of agitation are optimized. The maximum hydrolysis of 78% is achieved at 0.2% enzyme loading (w/v), 30 °C temperature, 165 W of ultrasonication power at 25 kHz and 66% duty cycle. It was observed that the enzymatic pre-hydrolysis under the influence of ultrasound drastically reduces the reaction time from 24 h to 40 min as compared to conventional stirring with improved yield.  相似文献   

10.
The effect of the dc bias on the compositional ratio, resistivity, and deposition rate for tungsten nitride (WNX) films prepared by rf-dc coupled magnetron sputtering have been investigated in detail. The value of the film compositional ratio (N/W) is significantly decreased from 0.8 to 0.2 with increasing the target dc bias voltage. The increase of the target dc bias voltage from −100 to −500 V results in a dramatical decrease in the resistivity of WNX films. It is shown that the N/W ratio and the resistivity of WNX thin films deposited at the target dc bias voltage of −200 V are about 0.5 and 370 μΩ cm, respectively.  相似文献   

11.
《Ultrasonics sonochemistry》2014,21(5):1866-1874
This study investigated the mechanical bioeffects exerted by acoustic droplet vaporization (ADV) under different experimental conditions using vessel phantoms with a 200-μm inner diameter but different stiffness for imitating the microvasculature in various tumors. High-speed microscopy, passive cavitation detection, and ultrasound attenuation measurement were conducted to determine the morphological characteristics of vascular damage and clarify the mechanisms by which the damage was initiated and developed. The results show that phantom erosion was initiated under successive ultrasound exposure (2 MHz, 3 cycles) at above 8-MPa peak negative pressures (PNPs) when ADV occurred with inertial cavitation (IC), producing lesions whose morphological characteristics were dependent on the amount of vaporized droplets. Slight injury occurred at droplet concentrations below (2.6 ± 0.2) × 106 droplets/mL, forming shallow and rugged surfaces on both sides of the vessel walls. Increasing the droplet concentration to up to (2.6 ± 0.2) × 107 droplets/mL gradually suppressed the damage on the distal wall, and turned the rugged surface on the proximal wall into tunnels rapidly elongating in the direction opposite to ultrasound propagation. Increasing the PNP did not increase the maximum tunnel depth after the ADV efficiency reached a plateau (about 71.6 ± 2.7% at 10 MPa). Increasing the pulse duration effectively increased the maximum tunnel depth to more than 10 times the diameter of the vessel even though there was no marked enhancement in IC dose. It can be inferred that substantial bubble generation in single ADV events may simultaneously distort the acoustic pressure distribution. The backward ultrasound reinforcement and forward ultrasound shielding relative to the direction of wave propagation augment the propensity of backward erosion. The results of the present work provide information that is valuable for the prevention or utilization of ADV-mediated mechanical bioeffects in clinical applications.  相似文献   

12.
《Current Applied Physics》2010,10(4):1227-1230
A biotinylated anti-rat C-reactive protein (CRP) antibody was ingeniously prepared by the reaction of the unmodified antibody with a water-soluble sulfosuccinimidyl-6-(biotinamido)hexanoate. The molar biotin incorporation of the resulting modified antibody was found as 5.82. A flow-type indirect-competitive quartz crystal microbalance immunosensor system was constructed with the sensor chip immobilized with 2 mg/mL CRP as the coating antigen. When 200 μL of the modified antibody having the concentration of 0.250 mg/mL was added with a streptavidin-coated gold nanoparticle (GNP) to the immunosensor system, the frequency shift obtained was 139.8 ± 0.3 Hz. Compared to the frequency shift of 91.1 ± 1.3 Hz found with the addition of the unmodified antibody only, the signal augmentation after GNP binding amounted to 53.4%, which resulted in sensitivity improvement of the current immunosensor.  相似文献   

13.
In this paper, a mid-/long-wave dual-band detector which combined PπMN structure and unipolar barrier was developed based on type-II InAs/GaSb superlattice. A relevant 320 × 256 focal plane array (FPA) was fabricated. Unipolar barrier and PπMN structure in our dual band detector structure were used to suppress cross-talk and dark current, respectively. The two channels, with respective 50% cut-off wavelength at 4.5 μm and 10 μm were obtained. The peak quantum efficiency (QE) of mid wavelength infrared (MWIR) band and long wavelength infrared (LWIR) band are 53% at 3.2 μm under no bias voltage and 40% at 6.4 μm under bias voltage of −170 mV, respectively. And the dark current density under 0 and −170 mV of applied bias are 1.076 × 10−5 A/cm2 and 2.16 × 10−4 A/cm2. The specific detectivity of MWIR band and LWIR band are 2.15 × 1012 cm·Hz1/2/W at 3.2 μm and 2.31 × 1010 cm·Hz1/2/W at 6.4 μm, respectively, at 77 K. The specific detectivity of LWIR band maintains above 1010 cm·Hz1/2/W at the wavelength range from 4.3 μm to 10.2 μm under −170 mV. The cross-talk, selectivity parameter at 3.0 μm, about 0.14 was achieved under bias of −170 mV. Finally, the thermal images were taken by the fabricated FPA at 77 K.  相似文献   

14.
《Solid State Ionics》2006,177(19-25):1849-1853
Single phase materials of the La(2−x)SrxMnOδ (0.6  x  2.0) solid solution series were prepared via solid state reaction. The structure of each material was examined at room temperature and determined to be tetragonal for all phases examined. An expansion in lattice volume was observed on increasing lanthanum content. The stability and thermal expansion of each member of the solid solution series was determined via the use of in situ high temperature X-ray diffraction. It was found that all materials remained stable up to a temperature of 800 °C. Thermal expansion coefficients were found to be in the region of 15 × 10 6 K 1 for La(2−x)SrxMnOδ compounds where x > 1.4. The electrical conductivity of each phase was also determined over a similar temperature range with a maximum value of ∼6 Scm 1 at 900 °C for the x = 1.8 phase.  相似文献   

15.
We report on heterostructure bandgap engineered midwave infrared photodetectors based on type-II InAs/GaSb strained layer superlattices with high operating temperatures. Bandgap and bandoffset tunability of antimonide based systems have been used to realize photodiodes and photoconductors. A unipolar barrier photodiode, pBiBn, and an interband cascade photovoltaic detector have been demonstrated with a 100% cutoff wavelength of 5 μm at 77 K. The pBiBn detector demonstrated operation up to room temperature and the cascade detector up to 420 K. A dark current density of 1.6 × 10−7 A/cm2 and 3.6 × 10−7 A/cm−2 was measured for the pBiBn and interband cascade detector, respectively, at 80 K. A responsivity of 1.3 A/W and 0.17 A/W was observed at −30 mV and −5 mV of applied bias for pBiBn and cascade detector, respectively, at 77 K. The experimental results have been explained by correlating them with the operation of the devices.  相似文献   

16.
The local adsorption site of the monotartrate and bitartrate species of R,R-tartaric acid deposited on Cu(110) have been determined by scanned-energy mode photoelectron diffraction (PhD). In the monotartrate phase the molecule is found to adsorb upright through the O atoms of the single deprotonated carboxylic acid (carboxylate) group, which are located in different off-atop sites with associated Cu―O bond lengths of 1.92 ± 0.08 Å and 1.93 ± 0.06 Å; the plane of the carboxylate group is tilted by 17 ± 6° off the surface normal. The bitartrate species adopts a ‘lying down’ orientation, bonding to the surface through all four O atoms of the two carboxylate groups, also in off-atop sites. Three slightly different models give comparably good fits to the PhD data, but only one of these is similar to that predicted by earlier density functional theory calculations. This model is found to have Cu―O bond lengths of 1.93 ± 0.08 Å and 1.95 ± 0.08 Å, while the planes of the carboxylate groups are tilted by 38 ± 6° from the surface normal.  相似文献   

17.
Sensitivity Encoding (SENSE) is a widely used technique in Parallel Magnetic Resonance Imaging (MRI) to reduce scan time. Reconfigurable hardware based architecture for SENSE can potentially provide image reconstruction with much less computation time. Application specific hardware platform for SENSE may dramatically increase the power efficiency of the system and can decrease the execution time to obtain MR images. A new implementation of SENSE on Field Programmable Gate Array (FPGA) is presented in this study, which provides real-time SENSE reconstruction right on the receiver coil data acquisition system with no need to transfer the raw data to the MRI server, thereby minimizing the transmission noise and memory usage. The proposed SENSE architecture can reconstruct MR images using receiver coil sensitivity maps obtained using pre-scan and eigenvector (E-maps) methods. The results show that the proposed system consumes remarkably less computation time for SENSE reconstruction, i.e., 0.164 ms @ 200 MHz, while maintaining the quality of the reconstructed images with good mean SNR (29 + dB), less RMSE (< 5 × 10 2) and comparable artefact power (< 9 × 10 4) to conventional SENSE reconstruction. A comparison of the center line profiles of the reconstructed and reference images also indicates a good quality of the reconstructed images. Furthermore, the results indicate that the proposed architectural design can prove to be a significant tool for SENSE reconstruction in modern MRI scanners and its low power consumption feature can be remarkable for portable MRI scanners.  相似文献   

18.
The influence of temperature on optical measurements has been studied for determining fat and protein contents in complex food systems. A model system consisting of mixtures of fat, protein, water and emulsion was developed to create an imitation of complex food systems. The changes in optical properties of the system from 25 °C to 40 °C were measured in the wavelength from 1100 nm to 1670 nm. Irregular changes as a whole were founded and therefore a statistical method was needed to correct the temperature effect. A method called global robust temperature calibration model is proposed and the correction effect was validated. The results indicated that it can significantly reduce the temperature effect on optical measurement.  相似文献   

19.
This study investigated the effect of ultrasound assisted chicken cartilage collagen peptide (CP) treatment on the storage quality of chicken breast meat. There were five meat groups at 4 °C for 60 min as follows: untreatment (Control), immersing in deionized water (DW), ultrasound treatment in DW (UDW), immersing in CP (0.15 g/100 mL) solution and immersing in ultrasound combined with CP (UCP). The results showed that the drip and cooking loss of meat decreased significantly in UCP at 4 and −18 °C with the extension of storage time. A large amount of non-flowing water transformed into free water in the 4 °C for 5 d, and the smallest degree of water migration was observed at −18 °C in UCP. The texture parameters of UCP group were significantly improved, especially for decreased hardness and increased elasticity. Furthermore, there had no significant effect on the color of chicken breast.  相似文献   

20.
Tendons and ligaments have similar but slightly different structure and composition. Crimps of tendons and ligaments are morphological structures related to the elastic functional properties of these connective tissues. Aim of this study was to investigate the morphological arrangement of collagen fibres, fibrils and crimping pattern of suprapatellar (rectus femoris tendon-RFT and vastus intermedius tendon-VIT) and infrapatellar connective tissues (patellar ligament-PL) to relate their structural aspects to their common function role of leg extension. RFT, VIT and PL were removed from knees of Sprague–Dawley rats and light and electron microscopy (TEM and SEM) performed. Sagittal sections showed that collagen array and crimping pattern were similar in RFT and PL but differed from VIT. Morphometric analysis confirmed that crimp number was about the same in RFT and PL (5.4 ± 1.4 and 6.1 ± 2.8 respectively), but it was almost three times higher in VIT (14.5 ± 4.7). Similarly crimp top angle in RFT and PL (141.5 ± 15.0° and 146.2 ± 12.2° respectively) was significantly higher than in VIT (122.3 ± 14.8°) and the crimp base length was more than twice as wide in RFT (75.5 ± 22.6 μm) and PL (72.3 ± 28.9 μm) than in VIT (36 ± 14.1 μm). The smaller, fewer and most crimped crimps in VIT show that this tendon has a greater elastic recoil and responds to higher forces as among quadriceps muscles the vastus intermedius belly contributes the most during knee extension. By contrast, RFT acting as a “stopper” tendon also plays a ligament role by limiting an excessive flexion of the joint during postural rest position of the knee.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号