首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
PurposeTo investigate biexponential apparent diffusion parameters of prostate central gland (CG) cancer, stromal hyperplasia (SH), and glandular hyperplasia (GH) and compare with monoexponential apparent diffusion coefficient (ADC) value for discriminating prostate cancer from benign hyperplasia.Materials and MethodsTwenty-one CG cancer foci, 23 SH and 26 GH nodules in the CG were analyzed in 39 patients (19 with CG cancer, 20 with peripheral zone cancer but no CG cancer) who underwent preoperative conventional DWI (b-value 0, 1000 s/mm2) and a 10 b-value (range 0 to 3000 s/mm2) DWI. All of the cancer and hyperplastic foci on MR images were localized on the basis of histopathologic correlation. The ADC value of the monoexponential DWI, and the fast apparent diffusion coefficient (ADCf), slow apparent diffusion coefficient (ADCs) value and the fraction of ADCf (f) of the biexponential DWI were calculated for all of the lesions. Receiver operating characteristic (ROC) analysis was performed for the differentiation of CG cancer from SH and GH.ResultsThe ADC values (× 10? 3 mm2/s) were 0.87 ± 0.11, 1.06 ± 0.15, and 1.61 ± 0.27 in CG cancer, SH and GH foci, respectively, and differed significantly, yielding areas under the ROC curve (AUCs) of 1.00 and 0.80 for the differentiation of carcinoma from GH and SH, respectively. The ADCf (× 10? 3 mm2/s), ADCs (× 10? 3 mm2/s) and f for cancer were 1.92 ± 0.38, 0.53 ± 0.17, and 47.7 ± 6.1%, respectively, which were lower than the same values for GH (3.43 ± 0.65, 1.12 ± 0.21, 61.1 ± 8.7%) (all p < 0.01). The ADCf and ADCs for cancer were also lower than those for SH (3.11 ± 0.30, 0.79 ± 0.21) (all p < 0.01). The ADCf yielded AUCs (1.00, p > 0.01) that were comparable to those from ADC for the differentiation of cancer from GH, while ADCf yielded higher AUCs (0.92) compared with ADC (p < 0.01) for the differentiation of cancer from SH. ADCs and f revealed AUCs of 0.97 and 0.90, respectively, for the differentiation of cancer from GH, and the ADCs offered relatively lower AUCs (0.68) for differentiating cancer from SH.ConclusionBiexponential DWI could potentially improve the differentiation of prostate cancer in CG, and the ADCf of the biexponential model offers better accuracy than ADC.  相似文献   

2.
PurposeThe dependence of the direction-averaged diffusion-weighted imaging (DWI) signal in brain was studied as a function of b-value in order to help elucidate the relationship between diffusion weighting and brain microstructure.MethodsHigh angular resolution diffusion imaging (HARDI) data were acquired from two human volunteers with 128 diffusion-encoding directions and six b-value shells ranging from 1000 to 6000 s/mm2 in increments of 1000 s/mm2. The direction-averaged signal was calculated for each shell by averaging over all diffusion-encoding directions, and the signal was plotted as a function of b-value for selected regions of interest. As a supplementary analysis, similar methods were also applied to retrospective DWI data obtained from the human connectome project (HCP), which includes b-values up to 10,000 s/mm2.ResultsFor all regions of interest, a simple power law relationship accurately described the observed dependence of the direction-averaged signal as a function of the diffusion weighting. In white matter, the characteristic exponent was 0.56 ± 0.05, while in gray matter it was 0.88 ± 0.11. Comparable results were found with the HCP data.ConclusionThe direction-averaged DWI signal varies, to a good approximation, as a power of the b-value, for b-values between 1000 and 6000 s/mm2. The exponents characterizing this power law behavior were markedly different for white and gray matter, indicative of sharply contrasting microstructural environments. These results may inform the construction of microstructural models used to interpret the DWI signal.  相似文献   

3.
The evaluation of local muscle recruitment during a specific movement can be done indirectly by measuring changes in local blood flow. Intravoxel incoherent motion perfusion imaging exploits some properties of the magnetic resonance to measure locally microvascular perfusion, and seems ideally suited for this task. We studied the selectivity of the increase in intravoxel incoherent motion blood flow related parameter fD* in the muscles of 24 shoulders after two physical exam maneuvers, Jobe and Lift-off test (test order reversed in half of the volunteers) each held 2 min against resistance. After a lift-off, IVIM blood flow-related fD* was increased in the subscapularis (in 10−3 mm2 s−1, 3.24 ± 0.86 vs. rest 1.37 ± 0.58, p < 0.001) and the posterior bundle of deltoid (2.62 ± 1.34 vs. rest 0.77 ± 0.32, p < 0.001). Those increases were selective when compared with other rotator cuff muscles and deltoid bundles respectively. After a Jobe test, increase in fD* was scattered within the rotator cuff muscles, but was selective for the lateral deltoid compared to the other deltoid bundles (anterior, p < 0.001; posterior, p < 0.05). Those results were similar when the testing order was reversed. In conclusion, this study demonstrated a selective increase in local microvascular perfusion after specific muscle testing of the shoulder muscles with IVIM. This technique has the potential to non-invasively characterize perfusion-related musculoskeletal physiological as well as pathological processes.  相似文献   

4.
PurposeQualitative (assignment of lipid components) and quantitative (quantification of lipid components) analysis of lipid components were performed in skeletal muscle tissue of patients with muscular dystrophy in early phase of the disease as compared to control/normal subjects.MethodsProton nuclear magnetic resonance (NMR) spectroscopy based experiment was performed on the lipid extract of skeletal muscle tissue of patients with muscular dystrophy in early phase of the disease and normal individuals for the analysis of lipid components [triglycerides, phospholipids, total cholesterol and unsaturated fatty acids (arachidonic, linolenic and linoleic acid)]. Specimens of muscle tissue were obtained from patients with Duchenne muscular dystrophy (DMD) [n = 11; Age, Mean ± SD; 9.2 ± 1.4 years; all were males], Becker muscular dystrophy (BMD) [n = 12; Age, Mean ± SD; 21.4 ± 5.0 years; all were males], facioscapulohumeral muscular dystrophy (FSHD) [n = 11; Age, Mean ± SD; 23.7 ± 7.5 years; all were males] and limb girdle muscular dystrophy-2B (LGMD-2B) [n = 18; Age, Mean ± SD; 24.2 ± 4.1 years; all were males]. Muscle specimens were also obtained from [n = 30; Mean age ± SD 23.1 ± 6.0 years; all were males] normal/control subjects.ResultsAssigned lipid components in skeletal muscle tissue were triglycerides (TG), phospholipids (PL), total cholesterol (CHOL) and unsaturated fatty acids (arachidonic, linolenic and linoleic acid)]. Quantity of lipid components was observed in skeletal muscle tissue of DMD, BMD, FSHD and LGMD-2B patients as compared to control/normal subjects. TG was significantly elevated in muscle tissue of DMD, BMD and LGMD-2B patients. Increase level of CHOL was found only in muscle of DMD patients. Level of PL was found insignificant for DMD, BMD and LGMD-2B patients. Quantity of TG, PL and CHOL was unaltered in the muscle of patients with FSHD as compared to control/normal subjects. Linoleic acids were significantly reduced in muscle tissue of DMD, BMD, FSHD and LGMD-2B as compared to normal/control individuals.ConclusionsResults clearly indicate alteration of lipid metabolism in patients with muscular dystrophy in early phase of the disease. Moreover, further evaluation is required to understand whether these changes are primary or secondary to muscular dystrophy. In future, these findings may prove an additional and improved approach for the diagnosis of different forms of muscular dystrophy.  相似文献   

5.
PurposeTo investigate the value of use of intravoxel incoherent motion diffusion-weighted imaging (IVIM-DWI) as an adjunct to dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) to distinguish benign from malignant breast lesions.Materials and methodsRetrospective analysis of data pertaining to 117 patients with breast lesions who underwent DCE-MRI and IVIM-DWI examination with 3.0 T MRI was conducted. A total of 128 lesions were pathologically confirmed (47 benign and 81 malignant). Between-group differences in DCE-MRI parameters (Morphology, enhancement pattern, maximum slope of increase (MSI) and time–signal curve (TIC) type) and IVIM-DWI parameters (f value, D value and D* value) were assessed. Multivariate logistic regression was performed to identify variables that distinguished benign from malignant breast lesions. The diagnostic performance of DCE-MRI and DCE-MRI plus IVIM-DWI, to distinguish benign from malignant breast lesions, was evaluated using pathology results as the gold standard.ResultsLesion morphology, MSI, and TIC type (P < 0.05), but not the enhancement pattern (P > 0.05), were significantly different between the benign and malignant groups. The f (8.53 ± 2.14) and D* (7.64 ± 2.07) values in the malignant group were significantly higher than those in the benign group (7.68 ± 1.97 and 6.83 ± 2.13, respectively), while the D value (0.99 ± 0.22) was significantly lower than that (1.34 ± 0.17) in the benign group (P < 0.05 for all). On logistic regression analysis, the sensitivity, specificity and accuracy of DCE-MRI were 90.1%, 70.2% and 82.8% respectively; the corresponding figures for the combination of IVIM-DWI and DCE-MRI were 88.8%, 85.1%, and 87.5%respectively.ConclusionIVIM-DWI method as an adjunct to DCE-MRI can improve the specificity and accuracy in differential diagnosis of benign and malignant lesions of breast.  相似文献   

6.
IntroductionTo assess if parameters in intravoxel incoherent motion (IVIM) and diffusion tensor imaging (DTI) can be used to evaluate early renal fibrosis in a mouse model of diabetic nephropathy.Materials & methodsIn a population of 38 male CD1 mice (8 weeks old, 20–30 g), streptozotocin induced diabetes was created in 20 mice via a single intraperitoneal injection of streptozotocin at 150 mg/kg, while 18 mice served as control group. IVIM parameters were acquired at 0, 12 and 24 weeks after injection of streptozotocin using a range of b values from 0 to 1200 s/mm2. DTI parameters were obtained using 12 diffusion directions and lower b values of 0, 100 and 400 s/mm2. DTI and IVIM parameters were obtained using region of interests drawn over the renal parenchyma. Histopathological analysis of the right kidney was performed in all mice. Results were analyzed using an unpaired t-test with P < 0.05 considered statistically significant.ResultsRenal cortex fractional anisotropy (FA) was significantly lower in the diabetes group at week 12 as compared with the control group. Renal cortex apparent diffusion coefficient and tissue diffusivity were significantly higher in the diabetes group at week 12 compared with the control group at 12 weeks. Blood flow was significantly decreased at the renal medulla at 24 weeks. Histopathological analysis confirmed fibrosis in the diabetes group at 24 weeks.ConclusionFA is significantly reduced in diabetic nephropathy. FA might serve a potential role in the detection and therapy monitoring of early diabetic nephropathy.  相似文献   

7.
Background and purposeTo assess the sensitivity of non-localized, whole-head 1H-MRS to an individual's serial changes in total-brain NAA, Glx, Cr and Cho concentrations — metabolite metrics often used as surrogate markers in neurological pathologies.Materials and methodsIn this prospective study, four back-to-back (single imaging session) and three serial (successive sessions) non-localizing, ~3 min 1H-MRS (TE/TR/TI = 5/104/940 ms) scans were performed on 18 healthy young volunteers: 9 women, 9 men: 29.9 ± 7.6 [mean ± standard deviation (SD)] years old. These were analyzed by calculating a within-subject coefficient of variation (CV = SD/mean) to assess intra- and inter-scan repeatability and prediction intervals. This study was Health Insurance Portability and Accountability Act compliant. All subjects gave institutional review board-approved written, informed consent.ResultsThe intra-scan CVs for the NAA, Glx, Cr and Cho were: 3.9 ± 1.8%, 7.3 ± 4.6%, 4.0 ± 3.4% and 2.5 ± 1.6%, and the corresponding inter-scan (longitudinal) values were: 7.0 ± 3.1%, 10.6 ± 5.6%, 7.6 ± 3.5% and 7.0 ± 3.9%. This method is shown to have 80% power to detect changes of 14%, 27%, 26% and 19% between two serial measurements in a given individual.ConclusionsSubject to the assumption that in neurological disorders NAA, Glx, Cr and Cho changes represent brain-only pathology and not muscles, bone marrow, adipose tissue or epithelial cells, this approach enables us to quantify them, thereby adding specificity to the assessment of the total disease load. This will facilitate monitoring diffuse pathologies with faster measurement, more extensive (~90% of the brain) spatial coverage and sensitivity than localized 1H-MRS.  相似文献   

8.
BackgroundThe left ventricle (LV) wall thickness is an important and routinely measured cardiologic parameter. Here we introduce three-dimensional (3D) mapping of LV wall thickness and function using a self-gated magnetic resonance (MR) sequence for ultra-high-field 11.7-T MR cine imaging of mouse hearts.Methods and resultsSix male C57BL/6-j mice were subjected to 11.7-T MR imaging (MRI). Three standard views—short axis, long axis four-chamber, and long axis two-chamber—and eight consecutive short axis scans from the apex to base were performed for each mouse. The resulting 11 self-gated cine images were used for fast low-angle shot analysis with a navigator echo over an observation period of approximately 35 min. The right ventricle (RV) and LV were identified in the short axis and four-chamber views. On 3D color-coded maps, the interventricular septum wall (diastole: 0.94 ± 0.05 mm, systole: 1.20 ± 0.09 mm) and LV free wall (diastole: 1.07 ± 0.15 mm, systole: 1.79 ± 0.11 mm) thicknesses were measured.ConclusionThis 3D wall thickness mapping technique can be used to observe regional wall thickness at the end-diastole and end-systole. Self-gated cine imaging based on ultra-high-field MRI can be used to accurately and easily measure cardiac function and wall thickness in normal mouse hearts. As in the preclinical study, this versatile and simple method will be clinically useful for the high-field-MRI evaluation of cardiac function and wall thickness.  相似文献   

9.
PurposeTo develop a 3D black-blood T2 mapping sequence with a combination of compressed sensing (CS) and parallel imaging (PI) for carotid wall imaging.Materials and methodsA 3D black-blood fast-spin-echo (FSE) sequence for T2 mapping with CS and PI was developed and validated. Phantom experiments were performed to assess T2 accuracy using a Eurospin Test Object, with different combination of CS and PI acceleration factors. A 2D multi-echo FSE sequence was used as a reference to evaluate the accuracy. The concordance correlation coefficient and Bland-Altman statistics were calculated. Twelve volunteers were scanned twice to determine the repeatability of the sequence and the intraclass correlation coefficient (ICC) was reported. Wall-lumen sharpness was calculated for different CS and PI combinations. Six patients with carotid stenosis > 50% were scanned with optimised sequence. The T2 maps were compared with multi-contrast images.ResultsPhantom scans showed good correlation in T2 measurement between current and reference sequence (r = 0.991). No significant difference was found between different combination of CS and PI accelerations (p = 0.999). Volunteer scans showed good repeatability of T2 measurement (ICC: 0.93, 95% CI 0.84–0.97). The mean T2 of the healthy wall was 48.0 ± 9.5 ms. Overall plaque T2 values from patients were 54.9 ± 12.2 ms. Recent intraplaque haemorrhage and fibrous tissue have higher T2 values than the mean plaque T2 values (88.1 ± 6.8 ms and 62.7 ± 9.3 ms, respectively).ConclusionThis study demonstrates the feasibility of combining CS and PI for accelerating 3D T2 mapping in the carotid artery, with accurate T2 measurements and good repeatability.  相似文献   

10.
BackgroundPrevious studies have demonstrated a correlation between Expanded Disability Status Scale (EDSS) and Diffusion Tensor Imaging (DTI) metrics, but the conclusions were based on evaluations of the entire cervical spinal cord.ObjectivesThe purpose of this study was to quantify the FA and MD values in the spinal cord of NMO patients, separating the lesion sites from the preserved sites, which has not been previously preformed. In addition, we attempted to identify a correlation with EDSS.MethodsDTI was performed in 11 NMO patients and 11 healthy individuals using a 1.5-T MRI scanner. We measured the FA and MD at ROIs positioned along the cervical spinal cord. The mean values of FA and MD at lesion, preserved and spinal cord sites were compared with those of a control group. We tested the correlations between the mean FA and MD with EDSS.ResultsFA in NMO patients was significantly reduced in lesion sites (0.44 vs. 0.55, p = 0.0046), preserved sites (0.46 vs. 0.55, p = 0.0015), and all sites (0.45 vs 0.55, p = 0.0013) while MD increased only in lesion sites (1.03 × 10 3 mm2/s vs. 0.90 × 10 3 mm2/s, p = 0.009). The FA demonstrated the best correlation with EDSS (r =  0.7603, p = 0.0086), particularly at lesion sites.ConclusionsThe results reinforce the importance of the FA index and confirm the hypothesis that NMO is a diffuse disease.  相似文献   

11.
PurposeTo explore the application of histogram analysis in preoperative T and N staging of gastric cancers, with a focus on characteristic parameters of apparent diffusion coefficient (ADC) maps.Materials and methodsEighty-seven patients with gastric cancers underwent diffusion weighted magnetic resonance imaging (b = 0, 1000 s/mm2), which generated ADC maps. Whole-volume histogram analysis was performed on ADC maps and 7 characteristic parameters were obtained. All those patients underwent surgery and postoperative pathologic T and N stages were determined.ResultsFour parameters, including skew, kurtosis, s-sDav and sample number, showed significant differences among gastric cancers at different T and N stages. Most parameters correlated with T and N stages significantly and worked in differentiating gastric cancers at different T or N stages. Especially skew yielded a sensitivity of 0.758, a specificity of 0.810, and an area under the curve (AUC) of 0.802 for differentiating gastric cancers with and without lymph node metastasis (P < 0.001). All the parameters, except AUClow, showed good or excellent inter-observer agreement with intra-class correlation coefficients ranging from 0.710 to 0.991.ConclusionCharacteristic parameters derived from whole-volume ADC histogram analysis could help assessing preoperative T and N stages of gastric cancers.  相似文献   

12.
We synthesized oxygen and paclitaxel (PTX) loaded lipid microbubbles (OPLMBs) for ultrasound mediated combination therapy in hypoxic ovarian cancer cells. Our experiments successfully demonstrated that ultrasound induced OPLMBs destruction significantly enhanced the local oxygen release. We also demonstrated that OPLMBs in combination with ultrasound (300 kHz, 0.5 W/cm2, 15 s) yielded anti-proliferative activities of 52.8 ± 2.75% and cell apoptosis ratio of 35.25 ± 0.17% in hypoxic cells at 24 h after the treatment, superior to other treatment groups such as PTX only and PTX-loaded MBs (PLMBs) with or without ultrasound mediation. RT-PCR and Western blot tests further confirmed the reduced expression of HIF-1α and MDR-1/P-gp after ultrasound mediation of OPLMBs. Our experiment suggests that ultrasound mediation of oxygen and drug-loaded MBs may be a useful method to overcome chemoresistance in the hypoxic ovarian cancer cells.  相似文献   

13.
ObjectiveMultiparametric magnetic resonance imaging (MRI) and PI-RADS (Prostate Imaging – Reporting and Data System) has become the standard to determine a probability score for a lesion being a clinically significant prostate cancer. T2-weighted and diffusion-weighted imaging (DWI) are essential in PI-RADS, depending partly on visual assessment of signal intensity, while dynamic-contrast enhanced imaging is less important. To decrease inter-rater variability and further standardize image evaluation, complementary objective measures are in need.MethodsWe here demonstrate a sequence enabling simultaneous quantification of apparent diffusion coefficient (ADC) and T2-relaxation, as well as calculation of the perfusion fraction f from low b-value intravoxel incoherent motion data. Expandable wait pulses were added to a FOCUS DW SE-EPI sequence, allowing the effective echo time to change at run time. To calculate both ADC and f, b-values 200 s/mm2 and 600 s/mm2 were chosen, and for T2-estimation 6 echo times between 64.9 ms and 114.9 ms were used.ResultsThree patients with prostate cancer were examined and all had significantly decreased ADC and T2-values, while f was significantly increased in 2 of 3 tumors. T2 maps obtained in phantom measurements and in a healthy volunteer were compared to T2 maps from a SE sequence with consecutive scans, showing good agreement. In addition, a motion correction procedure was implemented to reduce the effects of prostate motion, which improved T2-estimation.ConclusionsThis sequence could potentially enable more objective tumor grading, and decrease the inter-rater variability in the PI-RADS classification.  相似文献   

14.
BackgroundAssessment of muscle atrophy and fatty degeneration in brachial plexus injury (BPI) could yield valuable insight into pathophysiology and could be used to predict clinical outcome. The objective of this study was to quantify and relate fat percentage and cross-sectional area (CSA) of the biceps to range of motion and muscle force of traumatic brachial plexus injury (BPI) patients.MethodsT1-weighted TSE sequence and three-point Dixon images of the affected and non-affected biceps brachii were acquired on a 3 Tesla magnetic resonance scanner to determine the fat percentage, total and contractile CSA of 20 adult BPI patients. Regions of interest were drawn by two independent investigators to determine the inter-observer reliability. Paired Students' t-test and multivariate analysis were used to relate fat percentage, total and contractile CSA to active flexion and biceps muscle force.ResultsThe mean fat percentage 12 ± 5.1% of affected biceps was higher than 6 ± 1.0% of the non-affected biceps (p < 0.001). The mean contractile CSA 8.1 ± 5.1 cm2 of the affected biceps was lower than 19.4 ± 4.9 cm2 of the non-affected biceps (p < 0.001). The inter-observer reliability was excellent (ICC 0.82 to 0.96). The contractile CSA contributed most to the reduction in active flexion and muscle force.ConclusionQuantitative measurement of fat percentage, total and contractile CSA using three-point Dixon sequences provides an excellent reliability and relates with active flexion and muscle force in BPI.  相似文献   

15.
ObjectiveTo correlate intravoxel incoherent motion (IVIM) imaging and dynamic contrast-enhanced (DCE) MRI in head and neck squamous cell carcinoma (HNSCC).MethodsForty untreated patients with HNSCC were included retrospectively in the study. Perfusion fraction f, diffusion coefficient D and perfusion-related diffusion coefficient D* were extracted by bi-exponential fitting of IVIM data. Semi-quantitative DCE-MRI parameters, including positive enhancement integral (PEI) and maximum slope of increase (MSI), were calculated. The relationships between all variables were assessed by Spearman's test for correlation.Results27 primary tumors (PTs) and 23 lymph nodes (LNs) were analyzed. The residual sum of squares (RSS), used to assess the fit quality, was significantly different between PTs and LNs, with the last showing lower values. In LNs, D* and the product D* × f were positively related to both nPEI and nMSI, while no significant correlation was found in PTs.ConclusionEvident relationships between D* and D* × f and DCE-MRI perfusion measurements were found in LNs, while no significant association emerged in PTs. This presumably is due to the poorer agreement between the experimental data and curve fitting for PTs, as compared to LNs. Additional work is warranted to improve the reliability of the IVIM parameter estimations in primary HNSCCs.  相似文献   

16.
AimsTo develop a high-resolution, 3D late gadolinium enhancement (LGE) cardiovascular magnetic resonance imaging (MRI) technique for improved assessment of myocardial scars, and evaluate its performance against 2D breath-held (BH) LGE MRI using a surgically implanted animal scar model in the right ventricle (RV).Methods and resultsA k-space segmented 3D LGE acquisition using CENTRA-PLUS (Contrast ENhanced Timing Robust Acquisition with Preparation of LongitUdinal Signal; or CP) ordering is proposed. 8 pigs were surgically prepared with cardiac patch implantation in the RV, followed in 60 days by 1.5 T MRI. LGE with Phase-Sensitive Inversion Recovery (PSIR) were performed as follows: 1) 2DBH using pneumatic control, and 2) navigator-gated, 3D free-breathing (3DFB)-CP-LGE with slice-tracking. The animal heart was excised immediately after cardiac MR for scar volume quantification. RV scar volumes were also delineated from the 2DBH and 3DFB-CP-LGE images for comparison against the surgical standard. Apparent scar/normal tissue signal-to-noise ratio (aSNR) and contrast-to-noise ratio (aCNR) were also calculated.3DFB-CP-LGE technique was successfully performed in all animals. No difference in aCNR was noted, but aSNR was significantly higher using the 3D technique (p < 0.05). Against the surgical reference volume, the 3DFB-CP-LGE-derived delineation yielded significantly less volume quantification error compared to 2DBH-derived volumes (15 ± 10% vs 55 ± 33%; p < 0.05).ConclusionCompared to conventional 2DBH-LGE, 3DFB-LGE acquisition using CENTRA-PLUS provided superior scar volume quantification and improved aSNR.  相似文献   

17.
We report device linearity improvement and current enhancement in both a heterostructure FET (HFET) and a camel-gate FET (CAMFET) using InGaAs/GaAs high-low and GaAs high-medium-low doped channels, respectively. In an HFET, a low doped GaAs layer was employed to build an excellent Schottky contact. In a GaAs CAMFET, a low doped layer together withn+andp+layers formed a high-performance majority camel-diode gate. Both exhibit high effective potential barriers of >1.0 V and gate-to-drain breakdown voltages of >20.0 V (atIg=1.0 mA mm−1). A thin, high doped channel was used to enhance current drivability and to improve the transconductance linearity. A 2×100 μm2HFET had a peak transconductance of 230 mS mm−1and a current density greater than 800 mA mm−1. The device had a transconductance of more than 80 percent of the peak value over a wide drain current range of 200 to 800 mA mm−1. A 1.5×100 μm2CAMFET had a peak transconductance of 220 mS mm−1and a current density greater than 800 mA mm−1. Similarly, the device had a transconductance of more than 80 percent of the peak value over a wide drain current range of 160 to 800 mA mm−1. The improvement of device linearity and the enhancement of current density suggest that high-to-low doped-channel devices for both an HFET and a CAMFET are suitable for high-power large signal circuit applications.  相似文献   

18.
Spinal myeloma and metastatic cancer cause similar symptoms and show similar imaging presentations, thus making them difficult to differentiate. In this study, dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) was performed to differentiate between 9 myelomas and 22 metastatic cancers that present as focal lesions in the spine. The characteristic DCE parameters, including the peak signal enhancement percentage (SE%), the steepest wash-in SE% during the ascending phase and the wash-out SE%, were calculated by normalizing to the precontrast signal intensity. The two-compartmental pharmacokinetic model was used to obtain Ktrans and kep. All nine myelomas showed the wash-out DCE pattern. Of the 22 metastatic cancers, 12 showed wash-out, 7 showed plateau, and 3 showed persistent enhancing patterns. The fraction of cases that showed the wash-out pattern was significantly higher in the myeloma group than the metastatic cancer group (9/9 = 100% vs. 12/22 = 55%, P = .03). Compared to the metastatic cancer group, the myeloma group had a higher peak SE% (226% ± 72% vs. 165% ± 60%, P = .044), a higher steepest wash-in SE% (169% ± 51% vs. 111% ± 41%, P = .01), a higher Ktrans (0.114 ± 0.036 vs. 0.077 ± 0.028 1/min, P = .016) and a higher kep (0.88 ± 0.26 vs. 0.49 ± 0.23 1/min, P = .002). The receiver operating characteristic analysis to differentiate between these two groups showed that the area under the curve was 0.798 for Ktrans, 0.864 for kep and 0.919 for combined Ktrans and kep. These results show that DCE-MRI may provide additional information for making differential diagnosis to aid in choosing the optimal subsequent procedures or treatments for spinal lesions.  相似文献   

19.
《Solid State Ionics》2006,177(26-32):2363-2368
The mechanism and kinetics of water incorporation in the double perovskites Ва4Ca2Nb2O11 and Sr6Ta2O11 has been investigated (T = 300÷500 °C and aH2O = 1 · 10 3÷2.2 · 10 2). The formation of hydration products Ba4Ca2Nb2O11·xH2O and Sr6Ta2O11·xH2O (0.2 < x < 0.50) was limited by the diffusion of H2O. It has been found that the concentration dependences of H2O are the same for both samples: small increasing of H2O with increasing x. The temperature dependences of the chemical diffusion coefficients of water for compositions of Ba4Ca2Nb2O11·0.35H2O and Sr6Ta2O11·0.35H2O could be described with close activation energies of Ea = 0.38 ± 0.03 eV and Ea = 0.49 ± 0.03 eV, respectively. The chemical diffusion coefficients of water are nearly one order of magnitude smaller for tantalate Sr6Ta2O11. This result correlates with lower oxygen and proton conductivities in Sr6Ta2O11 as the consequence of lower mobilities.  相似文献   

20.
This work was to study the contact interface between a set of used hand taps and another new one based on the regional scanning of ultrasound. The contact image was a novel disclosure for hand taps contact. The objective of this work was to provide a wear diagnosis by making a comparison of contact area between the used and the new hand taps. The 2D maps showed an apparent change not only in area sizes but also in contact shapes between the used and the new hand taps. The 3D contact images also provided useful information to show the degree of contact.The contact area between the tap and the workpiece was calculated using an image analysis software package. The range of contact areas varied from 2.49 mm2 to 35.31 mm2 for the used hand taps and from 1.19 mm2 to 28.55 mm2 for the new taps, depending on the definition of the contrast ratio. The result provided another scientific data for users to decide a correct timing for the tool replacement. In addition, maps of reflection coefficient and pressure contour distribution were presented. The range of contact pressure varied from 2.5 Mpa to 4.2 Mpa.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号