We describe the use of two-dimensional ultrashort echo time (2D UTE) sequences with minimum TEs of 8 μs to image and quantify cortical bone on a clinical 3T scanner. An adiabatic inversion pulse was used for long T(2) water and fat signal suppression. Adiabatic inversion prepared UTE acquisitions with varying TEs were used for T(2) measurement. Saturation recovery UTE acquisitions were used for T(1) measurement. Bone water concentration was measured with the aid of an external reference phantom. UTE techniques were evaluated on cadaveric specimens and healthy volunteers. A signal-to-noise ratio of around 30, contrast-to-noise ratio of around 27/20 between bone and muscle/fat were achieved in tibia in vivo with a nominal voxel size of 0.23 × 0.23 × 6.0 mm(3) in a scan time of 5 min. A mean T(1) of 223 ± 11 ms and mean T(2) of 390 ± 19 μs were found. Mean bone water concentrations of 23.3 ± 1.6% with UTE and 21.7 ± 1.3% with adiabatic inversion prepared UTE sequences were found in tibia in five normal volunteers. The results show that in vivo qualitative and quantitative evaluation of cortical bone is feasible with 2D UTE sequences.  相似文献   

2.
PurposeTo investigate the correlations between cortical bone microstructural properties and total water proton density (TWPD) obtained from three-dimensional ultrashort echo time Cones (3D-UTE-Cones) magnetic resonance imaging techniques.Materials and methods135 cortical bone samples were harvested from human tibial and femoral midshafts of 37 donors (61 ± 24 years old). Samples were scanned using 3D-UTE-Cones sequences on a clinical 3T MRI and on a high-resolution micro-computed tomography (μCT) scanner. TWPD was measured using 3D-UTE-Cones MR images. Average bone porosity, pore size, and bone mineral density (BMD) were measured from μCT images at 9 μm voxel size. Pearson's correlation coefficients between TWPD and μCT-based measures were calculated.ResultsTWPD showed significant moderate correlation with both average bone porosity (R = 0.66, p < 0.01) and pore size (R = 0.57, p < 0.01). TWPD also showed significant strong correction with BMD (R = 0.71, p < 0.01).ConclusionsThe presented 3D-UTE-Cones imaging technique allows assessment of TWPD in human cortical bone. This quick UTE-MRI-based technique was capable of predicting bone microstructure differences with significant correlations. Such correlations highlight the potential of UTE-MRI-based measurement of bone water proton density to assess bone microstructure.  相似文献   

3.
Tendons and entheses are magnetic resonance (MR) “invisible” when imaged with conventional clinical pulse sequences. When the highly ordered, collagen-rich fibers in tendons and entheses are placed at the magic angle, dipolar interactions are decreased and their T2s are often considerably increased. The bulk magnetic susceptibility of tendons and entheses also varies with orientation to B0, leading to a direction-dependent resonance frequency shift. Ultrashort echo time (UTE) sequences with a minimum TE of 8 μs provide high signal from both tendons and entheses. The combination of a UTE sequence with an interleaved undersampled variable TE acquisition scheme provides a new approach for fast spectroscopic imaging of short T2 tissues. This UTE spectroscopic imaging (UTESI) technique provides quantitative information including T2?, chemical shift and resonance frequency shift due to bulk susceptibility effect. In this article, the orientational effects on tendons and entheses were investigated using a UTESI sequence on a clinical 3-T scanner. T2? was found to increase fivefold for tendons and twofold for entheses due to the magic angle effect. A resonance frequency shift up to 1.2 ppm was observed for both tendons and entheses due to the bulk susceptibility effect when their orientation was changed from 0° to 90° relative to B0.  相似文献   

4.
5.
6.
In ultrashort TE (UTE) imaging, the short T2 values of the tissues of interest are comparable to the k-space readout duration, which result in significant T2 decay during k-space readout. This decay consequently causes significant effects on signal and contrast in UTE sequences, which we evaluate in this paper using models that incorporate the gradient slew rate slew and maximal constant gradient strength gmax, in conjunction with objects of diameter L. The resulting signal and contrast relationships demonstrate steep signal changes between T2 values of ~ 50–500 μs, corresponding to high T2 weighted contrast in this range. When γ⋅gmax2/(4π⋅slew) > 1/(2 L), termed the “ramp only” regime, gmax has no significant effect whereas decreasing slew leads to decreases in signal amplitude and shifts the contrast peak to higher T2 values. When γ⋅gmax2/(4π⋅slew) < 1/(2 L), termed the “mixed gradient” regime, both gmax and slew have significant effects, where decreases in either gmax or slew lead to lower signal amplitudes and shifts the contrast peak to higher T2 values. Under typical scan settings, the “ramp only” regime is usually dominant. Further, we demonstrate an unusual dependence of T2 weighted signal and contrast on object size, whereby objects with smaller values of L demonstrate lower signal amplitudes and peak contrast at higher T2 values, compared to otherwise identical objects with larger L. These results improve understanding of T2 weighted signal and contrast properties in short T2 tissue imaging with UTE.  相似文献   

7.
PurposeWe present three-dimensional adiabatic inversion recovery prepared ultrashort echo time Cones (3D IR-UTE-Cones) imaging of cortical bone in the hip of healthy volunteers using a clinical 3T scanner.MethodsA 3D IR-UTE-Cones sequence, based on a short pulse excitation followed by a 3D Cones trajectory, with a nominal TE of 32 μs, was employed for high contrast morphological imaging of cortical bone in the hip of heathy volunteers. Signals from soft tissues such as muscle and marrow fat were suppressed via adiabatic inversion and signal nulling. T2 value of the cortical bone was also calculated based on 3D IR-UTE-Cones acquisitions with a series of TEs ranging from 0.032 to 0.8 ms. A total of four healthy volunteers were recruited for this study. Average T2 values and the standard deviation for four regions of interests (ROIs) at the greater trochanter, the femoral neck, the femoral head and the lesser trochanter were calculated.ResultsThe 3D IR-UTE-Cones sequence provided efficient suppression of soft tissues with excellent image contrast for cortical bone visualization in all volunteer hips. Exponential single component decay was observed for all ROIs, with averaged T2 values ranging from 0.33 to 0.45 ms, largely consistent with previously reported T2 values of cortical bone in the tibial midshaft.ConclusionsThe 3D IR-UTE-Cones sequence allows in vivo volumetric imaging and quantitative T2 measurement of cortical bone in the hip using a clinical 3T scanner.  相似文献   

8.
The performance of T(2)-weighted spin-echo version of echo planar imaging (SE_EPI), conventional spin echo (SE) and fat-suppressed turbo spin-echo (TSE_SPIR) sequences for the detection of focal liver lesions was evaluated. Twenty patients that were included in our study, had CT examinations prior to the MR study and were scheduled for surgery for removal of liver lesions. All patients had intraoperative sonographic examinations. Qualitative and quantitative analysis of the images was performed. Overall image quality of SE_EPI sequences was better than SE (p<0.001) and similar to TSE_SPIR sequences. There were fewer motion and ghost artifacts on SE_EPI and TSE_SPIR images compared to SE images (p<0.001). Susceptibility artifacts were statistically equivalent on SE_EPI and SE images (p<0.001) while chemical shift artifacts were equally observed on SE and SE_EPI sequences. Overall image quality of EPI-SE and TSE_SPIR sequences was better compared to SE sequences. There was no significant difference in the number of lesions detected by each of the three sequences. Quantitative analysis showed that liver/lesion contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) of liver, lesion, spleen was higher on TSE_SPIR sequences (p<0.001) while SE_EPI and SE sequences showed non-significant differences (p>0.05). SE_EPI sequences of the liver resulted in fewer artifacts and shorter acquisition times than SE sequences. They provide a diagnostic performance similar to TSE_SPIR and better than that of SE sequences.  相似文献   

9.
The FID-Acquired-Echo sequence (FAcE) is a magnetic resonance imaging technique using fractional-echo acquisitions, with sequential separate sampling of the right and left k-space half planes. It reduces the minimal echo times by about a factor of two, compared to conventional full-(gradient)-echo sampling schemes. With this sequence, implemented on a commercial 1.5 Tesla whole body system, high resolution images are acquired with typical echo times between 3 and 4.5 msec. Using short echo times the signal dephasing caused by velocity and higher order spin motion is reduced. Further, due to the modified sampling scheme, the sequence exhibits, for triggered studies, partially a compensation of motion-induced phase shifts in the frequency-encoding direction. Thus, the sequence offers an alternative means for the reduction of motion-induced image artefacts to the use of flow compensating gradients, which usually makes a sequence more sensitive to higher order motion and introduces further eddy currents. Besides potential application for imaging of nuclei and tissues with short T2 relaxation times, and non-ECG-triggered in-flow angiography, the main application seems to be triggered-phase contrast imaging with focus on quantitation of blood flow. Its usefulness is largest in cases with irregular flow patterns, where considerable in-plane flow occurs.  相似文献   

10.
The shortest pulses periodically emitted directly from a mode-locked Ti:sapphire laser are approaching the two-optical-cycle range. In this region, the phase of the optical carrier with respect to the pulse envelope becomes important in nonlinear optical processes such as high-harmonic generation. Because there are no locking mechanisms between envelope and carrier inside a laser, their relative phase offset experiences random fluctuations. Here, we propose several novel methods to measure and to stabilize this carrier-envelope offset (CEO) phase with sub-femtosecond uncertainty. The stabilization methods are an important prerequisite for attosecond pulse generation schemes. Short and highly periodic pulses of a two-cycle laser correspond to an extremely wide frequency comb of equally spaced lines, which can be used for absolute frequency measurements. Using the proposed phase-measurement methods, it will be possible to phase-coherently link any unknown optical frequency within the comb spectrum to a primary microwave standard. Experimental studies using a sub-6-fs Ti:sapphire laser suggesting the feasibility of carrier-envelope phase control are presented. Received: 19 August 1999 / Published online: 8 September 1999  相似文献   

11.

Purpose

To assess the feasibility and to optimize imaging parameters of diffusion kurtosis imaging (DKI) in human kidneys.

Methods

The kidneys of ten healthy volunteers were examined on a clinical 3 T MR scanner. For DKI, respiratory triggered EPI sequences were acquired in the coronal plane (3 b-values: 0, 300, 600 s/mm2, 30 diffusion directions). A goodness of fit analysis was performed and the influence of the signal-to-noise ratio (SNR) on the DKI results was evaluated. Region-of-interest (ROI) measurements were performed to determine apparent diffusion coefficient (ADC), fractional anisotropy (FA) and mean kurtosis (MK) of the cortex and the medulla of the kidneys. Intra-observer and inter-observer reproducibility using Bland-Altman plots as well as subjective image quality of DKI were examined and ADC, FA, and MK parameters were compared.

Results

The DKI model fitted better to the experimental data (r = 0.99) with p < 0.05 than the common mono-exponential ADC model (r = 0.96).Calculation of reliable kurtosis parameters in human kidneys requires a minimum SNR of 8.31 on b = 0 s/mm2 images.Corticomedullary differentiation was possible on FA and MK maps. ADC, FA and MK revealed significant differences in medulla (ADC = 2.82 × 10− 3 mm2/s ± 0.25, FA = 0.42 ± 0. 05, MK = 0.78 ± 0.07) and cortex (ADC = 3.60 × 10− 3 mm2/s ± 0.28, FA = 0.18 ± 0.04, MK = 0.94 ± 0.07) with p < 0.001.

Conclusion

Our initial results indicate the feasibility of DKI in the human kidney presuming an adequate SNR. Future studies in patients with kidney diseases are required to determine the value of DKI for functional kidney imaging.  相似文献   

12.
The purpose of this study was to systematically investigate the effect of varying the echo time (TE) values and angle of the tendon to the main magnetic field (B(o)) upon the signal intensity observed with the magic angle phenomenon in tendons among most commonly used MR pulse sequences, including conventional spin echo (CSE), fast spin echo (FSE) and gradient echo (GRE) sequences. The intact bovine Achilles tendon was imaged using a clinical 1.5-T MR scanner. Magic angle phenomenon occurs in CSE, FSE and GRE sequences with different grade, appearing most severe in CSE, middle in FSE, and weakest in GRE sequence. In addition, the tendon signal changes produced by the magic angle phenomenon could be greatly reduced by increasing the TE to above a certain critical value in all three sequences. These critical TE values were different among CSE (40 msec), FSE (70 msec), and GRE (30 msec) sequences.  相似文献   

13.
《Physics letters. A》2020,384(27):126710
The energy exchange between photons and electrons has been investigated theoretically by ab initio approach based on time-dependent density functional theory. Using diamond as a concrete example, three types of resonance and cancellation in the transfer of energy are theoretically observed, that allows one to gain a useful independent insight into the interaction processes of attosecond light pulses with matter. Our results demonstrate the linearity in energy transfer from intense attosecond light pulses to solids, in contrast to the nonlinearity in energy transfer from intense femtosecond light pulses to solids as expected from the conventional point of view, opening new perspectives for attoscience.  相似文献   

14.
We demonstrate experimentally that an arbitrary phase and amplitude profile can be applied to an ultrashort pulse by use of an acousto-optic programmable dispersive filter (AOPDF). Our filter has a large group-delay range that extends over 3 ps and a 30% diffraction efficiency over 150 THz. Experiments were conducted on a kilohertz chirped-pulse amplification laser chain capable of generating 30-fs pulses without additional pulse shaping. Compensating for gain narrowing and residual phase errors with an AOPDF in place of the stretcher results in 17-fs transform-limited pulses. Arbitrary shaping of these 17-fs pulses is also demonstrated in both the temporal and the spectral domains.  相似文献   

15.
Ultrasonography is a convenient and widely used technique to look into the longitudinal muscle motion as it is radiation-free and real-time. The motion of localized parts of the muscle, disclosed by ultrasonography, spatially reflects contraction activities of the corresponding muscles. However, little attention was paid to the estimation of longitudinal muscle motion, especially towards estimation of dense deformation field at different depths under the skin. Yet fewer studies on the visualization of such muscle motion or further clinical applications were reported in the literature. A primal–dual algorithm was used to estimate the motion of gastrocnemius muscle (GM) in longitudinal direction in this study. To provide insights into the rules of longitudinal muscle motion, we proposed a novel framework including motion estimation, visualization and quantitative analysis to interpret synchronous activities of collaborating muscles with spatial details. The proposed methods were evaluated on ultrasound image sequences, captured at a rate of 25 frames per second from eight healthy subjects. In order to estimate and visualize the GM motion in longitudinal direction, each subject was asked to perform isometric plantar flexion twice. Preliminary results show that the proposed visualization methods provide both spatial and temporal details and they are helpful to study muscle contractions. One of the proposed quantitative measures was also tested on a patient with unilateral limb dysfunction caused by cerebral infarction. The measure revealed distinct patterns between the normal and the dysfunctional lower limb. The proposed framework and its associated quantitative measures could potentially be used to complement electromyography (EMG) and torque signals in functional assessment of skeletal muscles.  相似文献   

16.
Non-linear resonant ultrasound spectroscopy (NRUS) is a technique exploiting the significant non-linear behavior of damaged materials, related to the presence of damage. This study shows for the first time the feasibility of this technique for damage assessment in bone. Two samples of bovine cortical bone were subjected to a progressive damage experiment. Damage accumulation was progressively induced in the samples by mechanical testing. For independent assessment of damage, X-ray CT imaging was performed at each damage step, but only helped in the detection of the prominent cracks. Synchrotron micro-CT imaging and histology using epifluorescence microscopy were performed in one of the two samples at the last damage step and allowed detection of micro-cracks for this step. As the quantity of damage accumulation increased, NRUS revealed a corresponding increase in the non-linear response. The measured change in non-linear response is much more sensitive than the change in elastic modulus. The results suggest that NRUS could be a potential tool for micro-damage assessment in bone. Further work has to be carried out for a better understanding of the physical nature of damaged bone, and for the ultimate goal of in vivo implementation of the technique where bone access will be a challenging problem.  相似文献   

17.
So far, fast spectroscopic imaging (SI) using the U-FLARE sequence has provided metabolic maps indirectly via Fourier transformation (FT) along the chemical shift (CS) dimension and subsequent peak integration. However, a large number of CS encoding steps N(omega) is needed to cover the spectral bandwidth and to achieve sufficient spectral resolution for peak integration even if the number of resonance lines is small compared to N(omega) and even if only metabolic images are of interest and not the spectra in each voxel. Other reconstruction algorithms require extensive prior knowledge, starting values, and/or model functions. An adjusted CS phase encoding scheme (APE) can be used to overcome these drawbacks. It incorporates prior knowledge only about the resonance frequencies present in the sample. Thus, N(omega) can be reduced by a factor of 4 for many (1)H in vivo studies while no spectra have to be reconstructed, and no additional user interaction, prior knowledge, starting values, or model function are required. Phantom measurements and in vivo experiments on rat brain have been performed at 4.7 T to test the feasibility of the method for proton SI.  相似文献   

18.
Ultra-high-field clinical MRI scanners (e.g., 7 T and above) are becoming increasingly prevalent and can potentially enhance diagnostic ability through higher contrast, resolution and/or sensitivity. Diffusion-weighted MRI is a highly valued component in today's radiological exam and may benefit from the enhanced signal-to-noise ratio provided by high field with the appropriate imaging strategy. The most common diffusion pulse sequence readout (echo-planar imaging (EPI)) has been widely employed for in vivo human 7 T diffusion tensor imaging (DTI). In this article, we present results of brain DTI at 7 T with two diffusion-weighted imaging pulse sequence readouts: echo-planar imaging (EPI-DTI) and turbo spin echo (TSE-DTI). Results indicate that analogous coverage, quality and resolution typical of lower field (2 mm) can be obtained by properly processed EPI-DTI at 7 T, and, with some reduction in efficiency and sharpness, TSE-DTI at 7 T. Furthermore, 7 T TSE-DTI shows promise in obtaining higher-resolution results in targeted acquisitions of specific brain areas.  相似文献   

19.
A simple method that uses envelope functions of unbalanced interferometric (auto/cross) correlation signals has been presented for simultaneous visual detection of pulse chirp and asymmetry, without direction-of-time ambiguity in ultrashort laser pulses. The ambiguity issues of unbalanced interferometric correlation envelope (ICE) difference signals have been studied. It is found that unbalanced ICE difference signals are visually different corresponding to practically indistinguishable unbalanced interferometric autocorrelation (IAC) signals for a distinct symmetric–asymmetric pulse pair with identical intensity autocorrelation and power spectra. The theoretical analysis of ICE signals is supported by experimental unbalanced IAC signals obtained using 200 fs laser pulses from a cw mode-locked Nd:phosphate laser oscillator. PACS 42.65.Re; 42.50.Hz; 07.60.Ly  相似文献   

20.
The purpose of this investigation was to quantitatively evaluate the practical impact of alteration of key imaging parameters on image quality and artifacts in fast multi-planar gradient echo (GRE) pulse sequences. These include multi-planar GRASS (MPGR) and fast multi-planar spoiled GRASS (FMPSPGR). We developed a composite phantom with different T(1) and T(2) values comprising the range of common biological tissues, which was also subjected to periodic motion in order to evaluate motion effects. Magnetic resonance imaging was performed on a GE Signa 1.5-T system. Experimental variations in key parameters included excitation flip angle (FL), echo time (TE), repetition time (TR), and receive bandwidth (BW). Quantitative analysis consisted of signal-to-noise-ratio (SNR) and contrast (CN), image nonuniformity (NU), full-width-at-half-maximum (FWHM) (i.e., blurring or geometric distortion), and ghosting ratio (GR). We found that flip angle, TE, and TR play particularly critical roles in determining image signal, homogeneity, and ghosting artifact with these sequences. Optimum clinical application of these pulse sequences requires careful attention to these imaging parameters and to their complex interactions.  相似文献   