1.
PurposeTo present a method that uses a novel free-running self-gated acquisition to achieve isotropic resolution in whole heart 3D Cartesian cardiac CINE MRI.Material and methods3D cardiac CINE MRI using navigator gating results in long acquisition times. Recently, several frameworks based on self-gated non-Cartesian trajectories have been proposed to accelerate this acquisition. However, non-Cartesian reconstructions are computationally expensive due to gridding, particularly in 3D. In this work, we propose a novel highly efficient self-gated Cartesian approach for 3D cardiac CINE MRI. Acquisition is performed using CArtesian trajectory with Spiral PRofile ordering and Tiny golden angle step for eddy current reduction (so called here CASPR-Tiger). Data is acquired continuously under free breathing (retrospective ECG gating, no preparation pulses interruption) for 4–5 min and 4D whole-heart volumes (3D + cardiac phases) with isotropic spatial resolution are reconstructed from all available data using a soft gating technique combined with temporal total variation (TV) constrained iterative SENSE reconstruction.ResultsFor data acquired on eight healthy subjects and three patients, the reconstructed images using the proposed method had good contrast and spatio-temporal variations, correctly recovering diastolic and systolic cardiac phases. Non-significant differences (P > 0.05) were observed in cardiac functional measurements obtained with proposed 3D approach and gold standard 2D multi-slice breath-hold acquisition.ConclusionThe proposed approach enables isotropic 3D whole heart Cartesian cardiac CINE MRI in 4 to 5 min free breathing acquisition.  相似文献   

2.
The purpose of this study is to improve direct phosphorus (31P) MR imaging. Therefore, 3D density-adapted radially-sampled balanced steady-state free precession (bSSFP) sequences were developed and an iterative approach exploiting additional anatomical information from hydrogen (1H) data was evaluated. Three healthy volunteers were examined at B0 = 7 T in order to obtain the spatial distribution of the phosphocreatine (PCr) intensities in the human calf muscle with a nominal isotropic resolution of 10 mm in an acquisition time of 10 min. Three different bSSFP gradient schemes were investigated. The highest signal-to-noise ratio (SNR) was obtained for a scheme with two point-reflected density-adapted gradients. Furthermore, the conventional reconstruction based on a gridding algorithm was compared to an iterative method using an 1H MRI constraint in terms of a segmented binary mask, which comprises prior knowledge. The parameters of the iterative approach were optimized and evaluated by simulations featuring 31P MRI parameters. Thereby, partial volume effects as well as Gibbs ringing artifacts could be reduced. In conclusion, the iterative reconstruction of 31P bSSFP data using an 1H MRI constraint is appropriate for investigating regions where sharp tissue boundaries occur and leads to images that represent the real PCr distributions better than conventionally reconstructed images.  相似文献   

3.
In vivo 31P MRS provides a unique and important imaging tool for studying high-energy phosphate metabolism and bioenergetics noninvasively. However, compared to 1H MRS, 31P MRS with a relatively low gyromagnetic ratio (γ) has a lower and limited sensitivity even at ultrahigh field. The proof of concept has been recently demonstrated that the use of high dielectric constant (HDC) materials between RF coil and object sample could increase MRI signal and reduce required RF transmission power for reaching the same RF pulse flip angle in the region of interest. For low-γ MRS applications operated at relatively lower frequency, however, it demands the dielectric materials with a much higher permittivity for achieving optimal performance. We conducted a 31P MRS imaging study using ultra-HDC (uHDC; with a relative permittivity of ~ 1200) material blocks incorporated with an RF volume coil at ultrahigh field of 7.0 T. The experimental results from phantom and human calf muscle demonstrate that the uHDC technique significantly enhanced RF magnetic transmit field (B1+) and reception field (B1) and the gain could reach up to two folds in the tissue near the uHDC blocks. The overall results indicate that the incorporation of the uHDC materials having an appropriate permittivity value with a RF coil can significantly increase detection sensitivity and reduces RF transmission power for X-nuclei MRS applications at ultrahigh field. The uHDC technology could provide an efficient, cost-effective engineering solution for achieving high detection sensitivity and concurrently minimizing tissue heating concern for human MRS and MRI applications.  相似文献   

4.
To quantify intragastric fat volume and distribution with accelerated magnetic resonance (MR) imaging using signal model-based dictionaries (DICT) in comparison to conventional parallel imaging (CG-SENSE). This study was approved by the local ethics committee and written informed consent was obtained. Seven healthy subjects were imaged after intake of a lipid emulsion and data at three different time points during the gastric emptying process was acquired in order to cover a range of fat fractions. Fully sampled and prospectively undersampled image data at a reduction factor of 4 were acquired using a multi gradient echo sequence at 1.5T. Retrospectively and prospectively undersampled data were reconstructed with DICT and CG-SENSE. Image quality of the retrospectively undersampled data was assessed relative to the fully sampled reference using the root mean square error (RMSE). In order to assess the agreement of fat volumes and intragastric fat distribution, Bland-Altman analysis and linear regression were performed on the data. The RMSE in intragastric content (ΔRMSE = 0.10 ± 0.01, P < 0.001) decreased significantly with DICT relative to CG-SENSE. CG-SENSE overestimated fat volumes (bias 2.1 ± 1.3 mL; confidence limits 5.4 and − 1.1 mL) in comparison to the prospective DICT reconstruction (bias − 0.1 ± 0.7 mL; confidence limits 1.8 and − 2.0 mL). There was a good agreement in fat distribution between the images reconstructed by retrospective DICT and the reference images (regression slope: 1.01, R2 = 0.961). Accelerating gastric MRI by integrating a dictionary-based signal model allows for improved image quality and increases accuracy of fat quantification during breathholds.  相似文献   

5.
《Solid State Ionics》2006,177(19-25):1747-1752
Oxygen tracer diffusion coefficient (D) and surface exchange coefficient (k) have been measured for (La0.75Sr0.25)0.95Cr0.5Mn0.5O3−δ using isotopic exchange and depth profiling by secondary ion mass spectrometry technique as a function of temperature (700–1000 °C) in dry oxygen and in a water vapour-forming gas mixture. The typical values of D under oxidising and reducing conditions at ∼ 1000 °C are 4 × 10 10 cm2 s 1 and 3 × 10 8 cm2 s 1 respectively, whereas the values of k under oxidising and reducing conditions at ∼ 1000 °C are 5 × 10 8 cm s 1 and 4 × 10 8 cm s 1 respectively. The apparent activation energies for D in oxidising and reducing conditions are 0.8 eV and 1.9 eV respectively.  相似文献   

6.
The objective of this study was to investigate the efficacy of high intensity ultrasound on the fermentation profile of Lactobacillus sakei in a meat model system. Ultrasound power level (0–68.5 W) and sonication time (0–9 min) at 20 °C were assessed against the growth of L. sakei using a Microplate reader over a period of 24 h. The L. sakei growth data showed a good fit with the Gompertz model (R2 > 0.90; SE < 0.042). Second order polynomial models demonstrated the effect of ultrasonic power and sonication time on the specific growth rate (SGR, μ, h−1) and lag phase (λ, h). A higher SGR and a shorter lag phase were observed at low power (2.99 W for 5 min) compared to control. Conversely, a decrease (p < 0.05) in SGR with an increase in lag phase was observed with an increase in ultrasonic power level. Cell-free extracts obtained after 24 h fermentation of ultrasound treated samples showed antimicrobial activity against Staphylococcus aureus, Listeria monocytogenes, Escherichia coli and Salmonella typhimurium at lower concentrations compared to control. No significant difference (p < 0.05) among treatments was observed for lactic acid content after a 24 h fermentation period. This study showed that both stimulation and retardation of L. sakei is possible, depending on the ultrasonic power and sonication time employed. Hence, fermentation process involving probiotics to develop functional food products can be tailored by selection of ultrasound processing parameters.  相似文献   

7.
《Solid State Ionics》2006,177(19-25):1725-1728
Apatite-type La10  xSi6  yAlyO27  3x/2  y/2 (x = 0–0.33; y = 0.5–1.5) exhibit predominant oxygen ionic conductivity in a wide range of oxygen partial pressures. The conductivity of silicates containing 26.50–26.75 oxygen atoms per formula unit is comparable to that of gadolinia-doped ceria at 770–870 K. The average thermal expansion coefficients are (8.7–10.8) × 10 6 K 1 at 373–1273 K. At temperatures above 1100 K, silicon oxide volatilization from the surface layers of apatite ceramics and a moderate degradation of the ionic transport with time are observed under reducing conditions, thus limiting the operation temperature of Si-containing solid electrolytes.  相似文献   

8.
The fabrication method and the pyroelectric response of a single element infrared sensor based lead zirconate titanate (PZT) particles and polyvinylidene fluoride P(VDF-TrFE) copolymer composite thick film is reported in this paper. A special thermal insulation structure, including polyimide (PI) thermal insulation layer and thermal insulation tanks, was used in this device. The thermal insulation tanks were fabricated by laser micro-etching technique. Voltage responsivity (RV), noise voltage (Vnoise), noise equivalent power (NEP), and detectivity (D*) of the PZT/P(VDF-TrFE) based infrared sensor are 1.2 × 103 V/W, 1.25 × 106 V Hz1/2, 1.1 × 10−9 W and 1.9 × 108 cm Hz1/2 W−1 at 137.3 Hz modulation frequency, respectively. The thermal time constant of the infrared sensor τT was about 15 ms. The results demonstrate that the composite infrared sensor show a high detectivity at high chopper frequency, which is an essential advantage in infrared detectors and some other devices.  相似文献   

9.
PurposeBiochemical imaging of glycosaminoglycan chemical exchange saturation transfer (gagCEST) could predict the depletion of glycosaminoglycans (GAG) in early osteoarthritis. The purpose of this study was to evaluate the relationship between the magnetization transfer ratio asymmetry (MTRasym) of gagCEST images and visual analog scale (VAS) pain scores in the knee joint.Materials and methodsThis retrospective study was approved by the institutional review board. A phantom study was performed using hyaluronic acid to validate the MTRasym values of gagCEST images. Knee magnetic resonance (MR) images of 22 patients (male, 9; female, 13; mean age, 50.3 years; age range; 25–79 years) with knee pain were included in this study. The MR imaging (MRI) protocol involved standard knee MRI as well as gagCEST imaging, which allowed region-of-interest analyses of the patellar facet and femoral trochlea. The MTRasym at 1.0 ppm was calculated at each region. The cartilages of the patellar facets and femoral trochlea were graded according to the Outerbridge classification system. Data regarding the VAS scores of knee pain were collected from the electronic medical records of the patients. Statistical analysis was performed using Spearman's correlation.ResultsThe results of the phantom study revealed excellent correlation between the MTRasym values and the concentration of GAGs (r = 0.961; p = 0.003). The cartilage grades on the MR images showed significant negative correlation with the MTRasym values in the patellar facet and femoral trochlea (r = −0.460; p = 0.031 and r = −0.543; p = 0.009, respectively). The VAS pain scores showed significant negative correlation with the MTRasym values in the patellar facet and femoral trochlea (r = −0.435; p = 0.043 and r = −0.671; p = 0.001, respectively).ConclusionThe pain scores were associated with the morphological and biochemical changes in articular cartilages visualized on knee MR images. The biochemical changes, visualized in terms of the MTRasym values of the gagCEST images, exhibited greater correlation with the pain scores than the morphological changes visualized on conventional MR images; these results provide evidence supporting the theory regarding the association of patellofemoral osteoarthritis with knee pain scores.  相似文献   

10.
PurposeTo develop a RF coil system for joint imaging of intracranial and extracranial arterial vessel wall at 3T.Materials and methodThe coil system consists of a 24-channel head coil combined with an 8-channel carotid coil. It is compared with a standard coil configuration (12-channel head coil + 4-channel neck coil + 8-channel carotid coil) for SNR and g-factors in phantoms and healthy volunteers. The clinical relevance of the proposed coil system is also evaluated in patients.ResultsIn phantom experiments, the SNR of the proposed coil system is 53% higher than the maximum SNR of the standard coil configuration at the center of the phantom which usually corresponds to the intracranial region of the head. The g-factors of the proposed coil system in the sagittal plane are lower than the standard coil configuration (by 10.8% and 26.6% for R = 2 and 4 respectively) in the same experiment. In healthy volunteer experiments, 55% of the pixels have SNR above 100 for the proposed coil system, which is 33% more than that of the standard coil configuration. The maximum g-factors in the standard configuration are higher than those from the new coil design by 12% at R = 2 and up to 36% at R = 4 in the sagittal plane. In patients, in-vivo intracranial and extracranial arterial wall images at an isotropic spatial resolution of 0.6 mm can be acquired using the proposed coil system. Plaques are well depicted from the images.ConclusionsThe performance of the proposed coil set is superior to the standard coil configuration, providing high SNR, low g-factor and good spatial coverage needed for simultaneous high resolution imaging of intracranial and extracranial arterial walls. Images acquired in 7.6 min using the proposed coil system can achieve an isotropic spatial resolution of 0.6 mm and can be used to depict plaques on the intracranial and extracranial arterial walls in patients.  相似文献   

11.
We demonstrate the first Cr4+:YAG passively Q-switched c-cut Nd:YVO4 self-Raman laser at 1168.6 nm based on the Stokes shift of 816 cm−1. At the pump power of 4.7 W, the maximum output power of the Stokes line at 1168.6 nm is 270.5 mW, corresponding to an optical conversion efficiency of 5.8%. The pulse width, pulse repetition rate, pulse energy and peak power are 8.8 ns, 35.8 kHz, 7.6 μJ and 0.86 kW, respectively. At the pump of 5.0 W, the Stokes line at 1097.2 nm based on Raman shift of 259 cm−1 also appears.  相似文献   

12.
We investigate the change of higher diffraction order images in holographic image storage and reconstruction process. In experiments, an s-polarized Ar+ laser (488.0 nm) was used to record permanent grating in the dye-doped liquid crystal, 4,4′-n-entylcyanobiphenyl (5CB) doped with 1 wt% methyl-red (MR), at a small incident angle. Higher diffraction order images were observed when the signal beam was focused in front of and behind the film. Then the film was illuminated by an s-polarized He–Ne laser (632.8 nm) in the direction perpendicular to the surface. The higher diffraction order images were reconstructed. A theory about the change of higher diffraction order images is developed, which is in good agreement with experimental results. The results show that the higher diffraction order provides a useful method for optical information processing.  相似文献   

13.
《Current Applied Physics》2009,9(5):1129-1133
Measurements of In2S3 and ZnIn2S4 sprayed thin films thermal characteristics have been carried out using the photodetection technique. The thermal conductivity k and diffusivity D were obtained using a new protocol based on photothermal signal parameters analysis. Measured values of k and D were respectively, (15.2 ± 0.85) W m−1K−1 and (69.8 ± 7.1) × 10−6 m2s−1 for In2S3, (7.2 ± 0.7) W m−1K−1 and (32.7 ± 4.3) × 10−6 m2s−1 for ZnIn2S4. These values are extremely important since similar compounds are more and more proposed as Cd-free alternative materials for solar cells buffer layers.  相似文献   

14.
PurposeHypoxia is an important marker for resistance to therapy. In this study, we quantify the macroscopic effects of R2* mapping in prostate cancer patients incorporating susceptibility matching and field strengths effects.Materials and methods91 patients were scanned without endorectal coil (ERC) at 3 T. Only when rectal gas was absent, data was included for analysis. Another group of 10 patients was scanned using a susceptibility matched ERC. To assess the residual contamination of R2 and macroscopic field non-uniformities, a group of 10 patients underwent ultra-high resolution 7 T MRI.ResultsOf the patients scanned at 3 T 60% presented rectal gas and were excluded, due to susceptibility artifacts. At 3 T the tumor was significantly different (P < 0.01) from the healthy surrounding tissue in R2* values at intrapatient level. Using the measured median R2* value of 24.9 s 1 at 3 T and 43.2 s 1 at 7 T of the peripheral zone, the minimum contribution of macroscopic susceptibility effects is 15% at 3 T.ConclusionR2* imaging might be a promising tool for hypoxia imaging, particularly when minimizing macroscopic susceptibility effects contaminating intrinsic R2* of tissue, such as rectal gas. At 3 T macroscopic effects still contribute 15% in the R2* value, compared to ultra-high resolution R2* mapping at 7 T.  相似文献   

15.
A simple method for synthesis of gold nanoparticles (AuNPs) using Aspergillum sp. WL-Au was presented in this study. According to UV–vis spectra and transmission electron microscopy images, the shape and size of AuNPs were affected by different parameters, including buffer solution, pH, biomass and HAuCl4 concentrations. Phosphate sodium buffer was more suitable for extracellular synthesis of AuNPs, and the optimal conditions for AuNPs synthesis were pH 7.0, biomass 100 mg/mL and HAuCl4 3 mM, leading to the production of spherical and pseudo-spherical nanoparticles. The biosynthesized AuNPs possessed excellent catalytic activities for the reduction of 2-nitrophenol, 3-nitrophenol, 4-nitrophenol, o-nitroaniline and m-nitroaniline in the presence of NaBH4, and the catalytic rate constants were calculated to be 6.3×10−3 s−1, 5.5×10−3 s−1, 10.6×10−3 s−1, 8.4×10−3 s−1 and 13.8×10−3 s−1, respectively. The AuNPs were also able to catalyze the decolorization of various azo dyes (e.g. Cationic Red X-GRL, Acid Orange II and Acid scarlet GR) using NaBH4 as the reductant, and the decolorization rates reached 91.0–96.4% within 7 min. The present study should provide a potential candidate for green synthesis of AuNPs, which could serve as efficient catalysts for aromatic pollutants degradation.  相似文献   

16.
The aim of this work was to investigate possible sex differences in the patterns of sodium deposition between muscle and skin using sodium MRI. A total of 38 subjects were examined for comparisons: 20 males, aged 25–79 years with a median age of 51; 18 females, aged 38–66 years, median age 53. All subjects underwent sodium MRI scans of the calf muscles together with cross sections through four calibration standards containing known sodium contents (10 mM, 20 mM, 30 mM, and 40 mM). Tissue sodium concentrations (TSC) in muscle and skin were then calculated by comparing signal intensities between tissues and reference standards using a linear analysis. A Wilcoxon rank sum test was applied to the ΔTSC (= TSCmuscle  TSCskin) series of males and females to examine if they were significantly different. Finally, a multiple linear regression was utilized to account for the effects from two potential confounders, age and body mass index (BMI). We found that sodium content appears to be higher in skin than in muscle for men, however women tend to have higher muscle sodium than skin sodium. This sex-relevant sodium deposition is statistically significant (P = 3.10 × 10 5) by the Wilcoxon rank sum test, and this difference in distribution seems to be more reliable with increasing age. In the multiple linear regression, gender still has a statistically significant effect (P < 1.0 × 10 4) on the difference between sodium deposition in muscle and skin, while taking the effects of age and BMI into account.  相似文献   

17.
High speed patterning of a 30 nm thick Aluminium thin film on a flexible Polyethylene Terephthalate substrate was demonstrated with the aid of Computer Generated Holograms (CGH׳s) applied to a phase only Spatial Light Modulator. Low fluence picosecond laser pulses minimise thermal damage to the sensitive substrate and thus clean, single and multi-beam, front side thin film removal is achieved with good edge quality. Interestingly, rear side ablation shows significant Al film delamination. Measured front and rear side ablation thresholds were Fth=0.20±0.01 J cm−2 and Fth=0.15±0.01 J cm−2 respectively. With laser repetition rate of 200 kHz and 8 diffractive spots, a film removal rate of R>0.5 cm2 s−1 was demonstrated during patterning with a fixed CGH and 5 W average laser power. The effective laser repetition rate was feff~1.3 MHz. The application of 30 stored CGH׳s switching up to 10 Hz was also synchronised with motion control, allowing dynamic large area multi-beam patterning which however, slows micro-fabrication.  相似文献   

18.
A resonant photoacoustic cell intended for laser-spectroscopy gas sensing is represented. This cell is a miniature imitation of a macro-scale banana-shaped cell developed previously. The parameters, which specify the cavity shape, are chosen so as not only to provide optimal cell operation at a selected acoustic resonance but also to reduce substantially the cell sizes. A miniaturized prototype cell (the volume of acoustic cavity of ∼5 mm3) adapted to the narrow diffraction-limited beam of near-infrared laser is produced and examined experimentally. The noise-associated measurement error and laser-initiated signals are studied as functions of modulation frequency. The background signal and the useful response to light absorption by the gas are analyzed in measurements of absorption for ammonia in nitrogen flow with the help of a pigtailed DFB laser diode oscillated near a wavelength of 1.53 μm. The performance of prototype operation at the second longitudinal acoustic resonance (the resonance frequency of ∼32.9 kHz, Q-factor of ∼16.3) is estimated. The noise-limited minimal detectable absorption normalized to laser-beam power and detection bandwidth is ∼8.07 × 10−8 cm−1 W Hz−1/2. The amplitude of the background signal is equivalent to an absorption coefficient of 2.51 × 10−5 cm−1. Advantages and drawbacks of the cell prototype are discussed. Despite low absorption-sensing performance, the produced miniaturized cell prototype shows a good capability of gas-leak detection.  相似文献   

19.
《Solid State Ionics》2006,177(1-2):121-127
Lithium cobalt vanadate LixCoVO4 (x = 0.8; 1.0; 1.2) has been prepared by a solid state reaction method. The XRD analysis confirms the formation of the sample. A new peak has been observed for Li1.0CoVO4 and for Li1.2CoVO4 indicating the formation of a new phase. The XPS analysis indicates the reduction in the oxidation of vanadium and oxygen with the addition of Li in LixCoVO4 (x = 0.8, 1.0, 1.2). The impedance analysis gives the conductivity value as 2.46 × 10 5, 6.16 × 10 5, 9 × 10 5 Ω 1 cm 1 for LixCoVO4 (x = 0.8; 1.0; 1.2), all at 623 K. The similarity in the bulk activation energy (Ea) and the activation enthalpy for migration of ions (Eω) indicate that the conduction in Li1.2CoVO4 has been due to hopping mechanism.  相似文献   

20.
《Solid State Ionics》2009,180(40):1683-1689
The complex perovskite (Pr0.75Sr0.25)1  xCr0.5Mn0.5O3  δ (PSCM) has been prepared and studied as possible anode material for high-temperature solid oxide fuel cells (SOFCs). PSCM exhibits GdFeO3-type structure and is both physically and chemically compatible with the conventional YSZ electrolyte. The reduction of PSCM resulted in structural change from orthorhombic Pbnm to cubic Pm-3m. Selected area electron diffraction (SAED) analysis on the reduced phases indicated the presence of a √2 × √2 × 2 superlattice. The total conductivity values of ∼ 75% dense Pr0.75Sr0.25Cr0.5Mn0.5O3  δ at 900 °C in air and 5% H2/Ar are 9.6 and 0.14 S cm 1 respectively. The conductivity of PSCM drops with decreasing Po2 and is a p-type conductor at all studied Po2. The average TEC of Pr0.75Sr0.25Cr0.5Mn0.5O3  δ is 9.3 × 10 6 K 1, in the temperature range of 100–900 °C and is close to that of YSZ electrolyte. The anode polarization resistance of PSCM in wet 5%H2 is 1.31 Ω cm2 at 910 °C and in wet CH4 at 930 °C; the polarization resistance is 1.29 Ω cm2. PSCM was unstable at 900 °C in unhumidified hydrogen. Cell performance measurements carried out using graded PSCM and La0.8Sr0.2MnO3 as anode and cathode respectively yielded a maximum power density of 0.18 W cm 2 in wet 5%H2/Ar at 910 °C and the corresponding current density was 0.44 A cm 2 at 0.4 V. The activation energy for the electrochemical cell operating in wet (3% H2O) 5%H2/Ar fuel is 85 kJ mol 1.  相似文献   