首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A simple and sensitive spectroelectrochemistry method for the determination of vitamin K 3 was developed by combining electrolysis and fluoremetry. This method was based on that vitamin K 3 was reduced at a glassy carbon electrode, and its product with characteristic fluorescence at 420 nm was determined with excitation wavelength at 309 nm. Under optimized electrochemical reaction conditions and fluorescent experiment parameters, the fluores-cence intensity was proportional to the concentration of vitamin K 3 in a range from 3.50×10 ?7 to 1.05×10 ?5 mol/L with a correlation coefficient of 0.9991, and detection limit was estimated to be 7.50×10 ?8 mol/L at a signal/noise ra-tio of 3. The relative standard deviation was less than 4.3%(n=5) and the recovery was in a range of 97%―105% for the determination of vitamin K 3 in pharmaceutical preparations. The result is satisfactory for the determination of vi-tamin K 3 as comparison to that from HPLC method.  相似文献   

2.
A spectrophotometric method for the determination of chlorhexidine acetate is described. The reaction between chlorhexidine acetate and chloranil took place in an alcohol-acetone solution at room temperature. The composition of the charge transfer complex is 1:2. Beer's law is obeyed in the concentration range of 15--270 μg·mL-1 with correlation coefficient 0.9995. The apparent molar absorptivity is 2.21×103 L·mol-1·cm-1 at 412 nm. The method is accurate (with a recovery of 100±1.6%) and precise (RSD=1.0%). It was successfully applied to determine chlorhexidine acetate in suppository or disinfectant solution.  相似文献   

3.
 A reversed-phase high performance liquid chromatography (HPLC) method was developed, validated, and used for the quantitative determination of gatifloxacin (GA) and ambroxol hydrochloride (AM), from its tablet dosage form. Chromatographic separation was performed on a HiQ Sil C18 column (250 mm×4.6 mm, 5 μm), with a mobile phase comprising of a mixture of 0.01 mol/L potassium dihydrogen orthophosphate buffer and acetonitrile (70∶30, v/v), and pH adjusted to 3 with orthophosphoric acid, at a flow rate of 1 mL/min, with detection at 247 nm. Separation was completed in less than 10 min. As per International Conference on Harmonisation (ICH) guidelines the method was validated for linearity, accuracy, precision, limit of quantitation, limit of detection, and robustness. Linearity of GA was found to be in the range of 10-60 μg/mL and that for AM was found to be 5-30 μg/mL. The correlation coefficients were 0.9996 and 0.9993 for GA and AM respectively. The results of the tablet analysis (n=5) were found to be 99.94% with ±0.25% standard deviation (SD) and 99.98% with±0.36% SD for GA and AM respectively. Percent recovery of GA was found to be 99.92%-100.02% and that of AM was 99.86%-100.16%. The assay experiment shows that the method is free from interference of excipients. This demonstrates that the developed HPLC method is simple, linear, precise, and accurate, and can be conveniently adopted for the routine quality control analysis of the tablet.  相似文献   

4.
A fluorocarbon-modified poly(N-isopropylacrylamide) has been synthesized by copolymerization of N-isopropyl acrylamide with a small amount of acrylate or methacrylate containing a perfluoroalkyl group. It was found that the hydrophilicity of macromolecular backbone is an important factor to the solution properties of the copolymers and that hydrophobic association between fluorocarbon groups is stronger than that between the corresponding hydrocarbon analogies. The viscosity of some of the copolymer solutions was very sensitive to temperature. It was dilatant at higher fluorocarbon comonomer content ( > 0.20-1.0 mol%) and was Newtonian at very low fluorocarbon comonomer content (0.03-0.2 mol% ) . Evidence for hydrophobic association of the fluorocarbon groups was obtained from the effects of adding Nad and surfactants on the solution viscosity. The LC-ST properties of these copolymers were studied by DSC method and this was also found to be consistent with hydrophobic association between the fluorocarbo  相似文献   

5.
Methotrexate(MTX) is an antineoplastic therapeutic medicine as antimetabolite of folic acid. In this paper, a sensitive and rapid ultra-performance liquid chromatographic(UPLC) method was developed and validated for the separation and determination of impurities in MTX drug substances. The UPLC method was accomplished on an Agilent Zorbax Extend C-18(50 mm 4.6 mm, 1.8 mm) with a gradient elution system composed of sodium dihydrogen phosphate in water(20 mmol/L, pH 3.0) and acetonitrile. The flow rate was 2.2 mL/min. The method was validated. The calibration curves displayed good linearity(r 0.999) within the tested concentration ranges. The limit of detection(LOD) and limit of quantification(LOQ) of the six analytes were all less than 0.774 mg/mL and 1.03 mg/mL. The relative standard deviation(RSD) for intra- and inter-day precision of the six analytes was less than 9.8%, including at the LOQ. The average recovery ranged from 95.2% to 103% except at the LOQ, where recovery ranged from 82.7% to 117%. The validated method was successfully used to determine the relative abundance of six impurities in the MTX drug substances.  相似文献   

6.
In a 0. 10 mol/L HAc-NaAc buffer solution (pH = 4. 59), a sensitive reduction peak of bleomycin was observed by linear sweep voltammetry at a Co/GC ion implantation modified electrode. The peak potential was-0. 73 V(iw. SCE). The peak current was proportional to the concentration of bleomycin over the range of 5.0 × 10-8-1.0× 10-6 and 1.0× 10-6-1. 0 × 10-5 mol/L with a detection limit of 2.0 × 10-8 mol/L. The electrochemical behavior of the reduction peak of bleomycin at the Co/GC modified electrode was studied by linear sweep and cyclic voltammetry and applied to the determination of bleomycin in urine. This method is simple, rapid and reliable. The reduction process is quasi-reversible. The experiments of AES and XPS showed that Co was surely implanted into the surface of GCE and the depth distribution of Co was in good agreement with Gooses normal distribution; the implanted Co at GCE improved the electrocatalytic activity.  相似文献   

7.
 The extraction behavior of platinum(IV) was studied with N-n-octylaniline as a function of different parameters, such as pH, concentrations of weak acids, mineral acids, reagents and elution time. A selective method was developed for the extraction chromatographic studies of platinum(IV) and its separation from several metal ions with N-n-octylaniline (liquid anion exchanger) as a stationary phase on silica gel. The quantitative extraction of platinum(IV) was observed with 0.067 mol/L N-n-octylaniline and 0.015 mol/L ascorbic acid at pH 1.0. Metal ion was stripped from the column with water and determined spectrophotometrically with stannous chloride method. The proposed method is free from the interference of a large number of cations and anions. Platinum(IV) was separated from pharmaceutical preparations, alloys and synthetic mixtures. Mutual separation scheme was developed for platinum(IV), palladium(II) and gold(III). The log-log plot of N-n-octylaniline concentration versus the distribution ratio indicates that the probable extracted species is [RR′NH+2 ]· Pt(C6H7O6)-3.  相似文献   

8.
Summary A simple and fast liquid chromatographic method is described, applicable to the routine analysis of isoxazolylpenicillins (cloxacillin, dicloxacillin, flucloxacillin) in biological fluids (plasma, urine). The method is based on a simple dilution step employed to destroy the protein binding, which is over 95%, and allows the detection of concentrations down to 10μg/ml. In order to analyze concentrations of less than 10μg/ml, a liquid-liquid extraction with dichloromethane must be executed prior to the reversed-phase analysis with absorbance detection at 206nm. The minimum detectable amounts of the isoxazolylpenicillins with this procedure are between 2.5 and 5.1 ng in 100μl plasma samples. The stability of the penicillin samples in aqueous solutions (stock solutions, eluents) was investigated and no significant degradation was observed during the storage and analysis of the samples. Furthermore, the degree of protein binding was established by using a suitable ultrafiltration technique, and the usefulness of the developed procedures in pharmacokinetic studies was demonstrated.  相似文献   

9.
the interaction of hemin with chloroquine,quinine and quinidine was investigated in 50% water-propylene glycol mixture at pH=9,8.1,7.4 and 6.8using a spectrophotometric method.The data could be well fitted into a model consistent with the formation of a 1:1 complex between the reacting partners.In addition,the results indicated that hemin complexed more strongly with quinidine than with chloroquine and quinine,and the binding constants were pH-dependent.Moreover,it was proved that the water-propylene glycol mixture is well suitable to the study of the systems containing hemin and quinolinebased drugs.  相似文献   

10.
It is important to quantitatively understand the methane adsorption and transport mechanism in coal for an evaluation of the reserves and for its production forecast. In this work, a block coal sample was chosen to perform the CH4 adsorption experiments using the gravimetric method at temperatures of 293.60 K, 311.26 K, 332.98 K and 352.55 K and pressures up to 19 MPa. The excess adsorption capacity of CH4 in dry block anthracite increased, followed by a sequence decrease with the increasing pressure. High temperature restrained the growth of the excess adsorption due to that the adsorption is an intrinsically physical and exothermic process. The excess adsorption peak decreased slowly with the increase of temperature and intersected at a pressure of more than 18 MPa; meanwhile, the pressure at the excess adsorption peak increased.The existing correlations were examined in terms of density rather than pressure. The DR+k correlation, with an average relative deviation of ±0.51%, fitted our data better than the others, with an average relative deviation of up to 2.29%. The transportation characteristics of CH4 adsorption was also investigated in this study, including the adsorption rate and diffusion in block coal. The kinetic data could be described by a modified unipore model. The adsorption rates were found to exhibit dependence on pressure and temperature at low pressures, while the calculated diffusivities exhibited little temperature dependence. In addition, the kinetic characteristics were compared between CH4 and CO2 adsorption on the block coal. The excess adsorption ratios of CO2 to CH4obtained from the DR+k model decreased with the increasing pressure.  相似文献   

11.
A simple kinetic spectrophotometric method was developed for the determination of ultratrace amounts of Se(IV). The method is based on the reduction of spadns by sulphide in micellar media. The reaction was monitored spectrophotometrically by measuring the decrease in the absorbance of spadns at 515 nm with a fixed-time method. The decrease in the absorbance of spadns is proportional to the concentration of Se(IV) in the range 0.5–100 ng/mL with a fixed time of 2.5–7.0 min from the initiation of the reaction. The limit of detection is 0.3 ng/mL Se(IV). The relative standard deviation for the determination of 0.02 and 0.10 μg/mL Se(IV) was 2.10 and 1.95%, respectively. The method was applied to the determination of Se(IV) in water. The text was submitted by the authors in English.  相似文献   

12.
This paper reports the electrochemical properties of sulpiride at a mercury electrode,especially its adsorptive characteristic,Sulpiride dissolved in a supporting electrolyte of a McIlvaine buffer at pH 6.8 represents a sensitive and well defined reduction wave by linear sweep stripping voltammetry.This method is based on the pre-concentration and the reduction of sulpiride at a hung mercury drop electrode.The reduction peak potential is -1.72V(vs.Ag-AgCl) and the peak current is proportional to the concentration of sulpiride in the range of 0.1-0.6 μg/mL.The detection limit is 0.0250μg/mL obtained under the experimental conditions selected in this work.The electrochemical properties of this system were investigated.and the proposed method was applied to the determination of sulpiride in pharmaceutical tablets with satisfactory results,It was compared well with the UV spectrophotometric method,showing a superior sensitivity.  相似文献   

13.
Preparation and Properties of HBS Lignin from Masson Pine   总被引:19,自引:0,他引:19  
In order to establish a new method for making cellulose and lignin from Masson pine, a high boiling solvent (HBS) pulping process with an aqueous solvent of 1,4-butanediol was investigated. Masson pine chips were pulped with a 70%--90% aqueous solution of 1,4-butanediol containing a small amount of a catalyst at 200--220℃ for 60--180 min. HBS Masson pine cellulose is suitable for making paper. Water-insoluble HBS lignin was separated from the liquor reaction mixture by water precipitation. The recovered high boiling solvent (RHBS) is able to be recycled as a pulping solvent, indicating that the HBS method is a pulping process of Masson pine which is energy saving, resources saving and pollution free. HBS lignin has a better chemical reactivity and a lower ash content than lignin sulfonate.  相似文献   

14.
The present study reports a sensitive electro-analytical method for the simultaneous determination of dihydroxybenzene isomers by using a thiadiazole film electrode, which was readily prepared by electropolymerization of 2,5-dimercapto-1,3,4-thiadiazole on a glassy carbon electrode with cyclic voltammetry. The functionalized electrode has a distinguishable and sensitive response to dihydroxybenzene isomers. Under the optimized conditions, the linear stripping peak currents showed good linear relationships with hydroquinone, catechol and resorcinol at concentration ranges 0.50-120, 0.50-110 and 1.00-110 μmol/L, and the detection limits are 0.1, 0.1 and 0.3 μmol/L, respectively. The proposed method is applicable to the simultaneous determination of dihydroxybenzene isomers in real samples with the relative standard deviations of less than 5.7% and the recovery rates of 95.6%-106%. The constructed electrode is characterized by simple preparation, good selectivity, and high sensitivity advantages.  相似文献   

15.
《色谱》2015,(6)
A simple and sensitive method for the separation and determination of isoproterenol from other doping drugs has been developed on thin layers of bismuth silicate,a synthetic inorganic ion exchanger as adsorbent in thin layer chromatography(TLC).A mixture of methanol and 0.1 mol/L formic acid(3∶7,v/v)was employed as the mobile phase.The development time was 32 min.The quantitative measurement were performed with a Camag TLC Scanner-3 at wavelength(λ)of 410 nm.The isoproterenol recovery in this procedure was 98.9%.The linear correlation coefficient was greater than 0.987 1 and the relative standard deviation(RSD)was less than 0.94.The limit of detection(LOD)and limit of quantification(LOQ)were 7.7×10-7mol/L and 3.85×10-6mol/L,respectively.This method has been applied in the determination of isoproterenol in dosage forms and in biological fluids.  相似文献   

16.
A rapid and sensitive liquid chromatography-tandem mass spectrometry(LC-MS/MS) method for the de- termination of cefotetan in human plasma was developed and validated. After the protein precipitation of sample with acetonitrile, the analyte and internal standard(IS), tramadol, were separated on a Zorbax XDB C8 column using ace- tonitrile/1%(volume fraction) formic acid(volume ratio 35:65, pH=2.5) as mobile phase at a flow rate of 1.0 mL/min with a 1 : 1 split. The detection was performed by electrospray ionization with positive ion mode, followed by multiple reaction monitoring of the transitions for cefotetan at m/z 576.3→460.2(quantifier) and m/z 576.3→432.2(qualifier) and for IS at m/z 264.1→58.1. Cefotetan and IS were eluted at 1.86 and 1.87 rain, respectively. The assay was linear over the concentration range of 0.1-100 gg/mL for 20 μL of human plasma only with intra- and inter-day preci- sions(expressed as the relative standard deviation) of less than 6.62% and accuracies(as relative error) of +1.31%. The method was applied to the pharmacokinetic study of a l-h intravenous infusion of 1.0 g of cefotetan disodium for human volunteers(n=6).  相似文献   

17.
 A simple, selective, sensitive, precise, simultaneous high performance liquid chromatographic analysis of serum samples and commercial tablet formulation containing hydrochlorothiazide, olmesartan medoxomil and irbesartan are reported. Good chromatographic separation was achieved using a μ-Bondapak, C18 column (15 cm×4.6 mm, 5 μm), and a mobile phase consisting of acetonitrile-0.2% acetic acid aqueous solution (50∶50, v/v) at a flow rate of 1.0 mL/min. The ultraviolet detector was set at a wavelength of 260 nm. Hydrochlorothiazide, olmesartan medoxomil, and irbesartan were eluted at 1.2, 3.8, and 4.4 min, respectively. No extraneous materials were found to interfere. The method uses protein precipitation with acetonitrile for the preparation of serum sample. The linear ranges for hydrochlorothiazide, olmesartan medoxomil, and irbesartan were 6.25-18.75, 20-60, and 75-225 ng/mL, respectively. The recoveries of hydrochlorothiazide, olmesartan medoxomil, and irbesartan in spiked samples were all greater than 98%, and their relative standard deviations were less than 2.0%. The limits of detection were 1, 2, and 2 ng/mL for hydrochlorothiazide, olmesartan medoxomil, and irbesartan, respectively, and the limits of quantification were 3 ng/mL, which allow their determination at the expected serum concentration levels.  相似文献   

18.
高效液相色谱-荧光检测法测定人血浆中匹伐他汀的含量   总被引:2,自引:0,他引:2  
 Pitavastatin belongs to the class of coenzyme A reductase inhibitors. Very few methods of assaying pitavastatin from human plasma are available in literature. An analytical method is presented for the determination of the drug from human plasma making use of the fluorescent property of the drug. The drug is extracted from plasma using ethyl acetate under neutral condition and then analyzed by reversed-phase high performance liquid chromatography (HPLC) with fluorescence detection (λEx 245 nm; λEm 420 nm). Analysis of pitavastatin was carried out on a C18 HPLC column using a gradient flow of mobile phase (0.01 mol/L monobasic potassium phosphate (pH 3.20)-acetonitrile, 63∶37, v/v). Fluorescein isothiocyanate was used as internal standard. The dynamic range of assay was 3 to 50 ng/mL. The intraday precision was less than 10% and accuracy ranged from 95.2% to 112.6%. The same for interday check was less than 12% and 92.8% to 105.1%, respectively. The drug was found to be stable under the assay conditions. The developed method is simple, precise, accurate, and stable. This indicates that it can be applied to routine analysis of this drug in human subjects where there are large numbers of samples without the need of specialized instruments like column switching.  相似文献   

19.
Silicate orange yellow phosphor used in white-light LED was prepared by microwave method. The structure and optical properties of phosphor were studied. Sr3SiO5∶Eu2+ phosphor synthesized by microwave method is tetragonal structure of Sr3SiO5 with uniform particle distribution. Luminescence spectrum is a broad band spectrum peaking at 575 nm. The peak of excitation is at 532 nm and phosphor can be excited by blue LED. The warm white light was obtained combined phosphor and blue LED. The CIE chromaticity coordinates and correlated color temperature of white light is (x=0.394, y=0.341) and 3 239 K respectively.  相似文献   

20.
Thermodynamic analysis of the reforming of methane with carbon dioxide alone ("dry reforming") and with carbon dioxide and steam together ("mixed reforming") is performed as part of a project which investigates the suitability of these endothermic reactions for the storage of solar thermal energy. The Gibbs free energy minimization method was employed to identify thermodynamically optimal operating conditions for dry reforming as well as mixed reforming with a desired H2/CO molar ratio of 2. The non-stoichiometric equilibrium model was developed using FactSage software to conduct the thermodynamic calculations for carbon formation, H2/CO ratio, CH4 conversion and H2 yield as a function of reaction temperature, pressure and reactant molar ratios. Thermodynamic calculations demonstrate that in the mixed reforming process, optimal operating conditions in a carbon-free zone are under H2O/CH4 /CO2 =1.0/1.0/0.5, p = 1 to 10 bar and T = 800 to 850℃ for the production of syngas with a H2 /CO molar ratio of 2. Under the optimal conditions, the maximum H2 yield of 88.0% is achieved at 1 bar and 850℃ with a maximum CH4 conversion of 99.3%. In the dry reforming process, a carbon formation regime is always present at a CO2/CH4 molar ratio of 1 for T = 700 1000℃ and p = 1-30 bar, whereas a carbon-free regime can be obtained at a CO2/CH4 molar ratio greater than 1.5 and T≥800℃.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号