首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Liquid chromatography with atmospheric pressure chemical ionisation mass spectrometry (LC/APCI-MS), using negative ion detection in a triple quadrupole instrument, was used for the determination of chlorophenols (CPs) in environmental samples. In-source collision-induced dissociation (CID) was compared with MS/MS fragmentation. In general, less fragmentation was observed in MS/MS as compared with in-source CID, with the latter providing more intense fragment ions due to chemical ionisation. Under MS/MS conditions [M - H - HCl](-) was the main fragment ion observed for all compounds except for pentachlorophenol, which showed no fragmentation. For multiple reaction monitoring (MRM) acquisition mode, the transition from [M - H](-) to [M - H - HCl](-) was selected, leading to detection limits down to 0.3 ng injected. Direct and headspace-solid-phase microextraction (HS-SPME) were used as preconcentration procedures for the analysis of CPs in wood and in industrially contaminated soils. CPs were quantified by standard addition, which led to good reproducibility (RSD between 4 and 11%) in both SIM and MRM modes, and detection limits down to ng/g. The combination of MS/MS and in-source CID allowed confirmation of the presence of CPs in environmental samples.  相似文献   

2.
A headspace solid-phase microextraction gas chromatography coupled with tandem mass spectrometry (HSSPME-GC-MS-MS) methodology for determination of brominated flame retardants in sediment and soil samples is presented. To the best of our knowledge, this is the first time that SPME has been applied to analyze polybrominated biphenyls (PBBs) and polybrominated diphenyl ethers (PBDEs) in environmental solid samples. Analyses were performed using 0.5-g solid samples moisturized with 2 mL water, employing a polydimethylsiloxane (PDMS) fiber coating, exposed to the headspace at 100 °C for 60 min. Several types of environmental solid samples were included in this study and the extraction efficiency was related to the organic matter content of the sample. Calibration was performed using real samples, and the method showed good linearity over a wide concentration range, precision, and afforded quantitative recoveries. The obtained detection limits were in the sub-ng g−1 for all the target analytes in both samples. The proposed procedure was applied to several marine and river sediments and soils, some of which were found to contain PBDEs at concentrations in the ng g−1 level; BDE-47, BDE-100, and BDE-99 were the major congeners detected. The proposed method constitutes a rapid and low-cost alternative for the analysis of the target brominated flame retardants in environmental solid samples, since the clean-up steps, fractionation, and preconcentration of extracts inherent to the classical multi-step solvent extraction procedures are avoided.   相似文献   

3.
In order to assess the true impact of each single enantiomer of pharmacologically active compounds (PACs) in the environment, highly efficient, fast and sensitive analytical methods are needed. For the first time this paper focuses on the use of ultrahigh performance supercritical fluid based chromatography coupled to a triple quadrupole mass spectrometer to develop multi-residue enantioselective methods for chiral PACs in environmental matrices. This technique exploits the advantages of supercritical fluid chromatography, ultrahigh performance liquid chromatography and mass spectrometry. Two coated modified 2.5 μm-polysaccharide-based chiral stationary phases were investigated: an amylose tris-3,5-dimethylphenylcarbamate column and a cellulose tris-3-chloro-4-methylphenylcarbamate column. The effect of different chromatographic variables on chiral recognition is highlighted. This novel approach resulted in the baseline resolution of 13 enantiomers PACs (aminorex, carprofen, chloramphenicol, 3-N-dechloroethylifosfamide, flurbiprofen, 2-hydroxyibuprofen, ifosfamide, imazalil, naproxen, ofloxacin, omeprazole, praziquantel and tetramisole) and partial resolution of 2 enantiomers PACs (ibuprofen and indoprofen) under fast-gradient conditions (<10 min analysis time).  相似文献   

4.
In current approaches for new drug development, highly sensitive and robust analytical methods for the determination of test compounds in biological samples are essential. These analytical methods should be optimized for every target compound. However, for biological samples that contain multiple compounds as new drug candidates obtained by cassette dosing tests, it would be preferable to develop a single method that allows the determination of all compounds at once. This study aims to establish a systematic approach that enables a selection of the most appropriate pretreatment method for multiple target compounds without the use of their chemical information. We investigated the retention times of 27 known compounds under different mobile phase conditions and determined the required pretreatment of human plasma samples using several solid‐phase and liquid–liquid extractions. From the relationship between retention time and recovery in a principal component analysis, appropriate pretreatments were categorized into several types. Based on the category, we have optimized a pretreatment method for the identification of three calcium channel blockers in human plasma. Plasma concentrations of these drugs in a cassette‐dose clinical study at microdose level were successfully determined with a lower limit of quantitation of 0.2 pg/mL for diltiazem, 1 pg/mL for nicardipine, and 2 pg/mL for nifedipine.  相似文献   

5.
The performance of gas chromatography coupled with tandem mass spectrometry (GC/MS/MS) was tested for the simultaneous determination of twelve pyrethroid insecticides. First, a comparison of two different ionization modes, electron ionization (EI) and negative chemical ionization (NCI), was carried out using MS and MS/MS. NCI-MS/MS provided the best results in terms of selectivity and sensitivity giving very low detection limits of 0.11 to 450 fg injected. The reliability of the method was confirmed through the evaluation of quality parameters such as accuracy (70-100%), and repeatability and reproducibility, with coefficients of variation below 15% and 10%, respectively. The applicability of the GC/MS/MS method to real samples and influence of matrix effects were evaluated through the analysis of spiked water, sediment and milk at 0.25 ng L(-1) , 5 ng g(-1) dry weight (dw) and 25 ng g(-1) (dw), respectively, of each pyrethroid insecticide considered. Using GC/NCI-MS/MS, matrix spectral interferences were minimized providing method limits of detection (MLODs) of 0.05-2.59 ng L(-1) , 0.10-87.7 pg g(-1) dw, 2.29-1071 pg g(-1) lipid weight (lw) for water, sediment and milk, respectively. To the best of our knowledge, the MLOD values found in our study were better than those reported in previous studies; in particular for sediment and food samples, they were one order of magnitude lower.  相似文献   

6.
7.
A novel multi-analyte method for the simultaneous determination of 46 compounds of environmental concern, most of them belonging to the category of persistent organic pollutants, was developed using high-performance liquid chromatography and the results were compared to those obtained by gas chromatography. This study was performed in perspective of a cumulative exposure assessment of substances of health concern in environments where high levels, relatively to airborne particulate matter, can be found. The target compounds included polychlorinated biphenyls, brominated flame–retardants and derivatives of polycyclic aromatic hydrocarbons.

The multi-analyte method was evaluated in air particulate matter in terms of reproducibility, linearity, recovery, limits of detection and quantification and matrix effect. The recovery was above 70% for all the analytes, whereas limits of quantification ranged between 23 and 390 pg?m?3 in liquid chromatography and less than ten times in gas chromatography–mass spectrometry.

Matrix effect was generally negligible for both the techniques, except the case of the detection of oxygenated derivatives of polycyclic aromatic hydrocarbons by gas chromatography.

In order to demonstrate the efficacy and to assess the method performances (accuracy and precision), both the techniques were applied to standard reference materials, and the results were compared, discussing their advantages and disadvantages.

The method was finally applied to a real sample of indoor airborne particulate matter with aerodynamic diameter ≤4 μm (PM4).

We demonstrated that liquid chromatography was the only technique able to analyse the 46 compounds, including thermally degradable ones, with a single chromatographic run without derivatisation steps. On the other hand, gas chromatography still presents higher sensitivity for the detection of some of the investigated compounds. This study can be considered only explorative and further improvements can be expected with new-generation LC-MS instruments (10–100 times more sensitive).  相似文献   

8.
Erythrocyte alkylresorcinols (5‐alkyl‐1,3‐dihydroxybenzenes) are potential biomarkers of wholegrain wheat and rye intake. However, their high‐throughput quantitative analysis by gas chromatography/mass spectrometry (GC/MS) is hindered by the time‐consuming sample preparation and, more importantly, by interfering compounds that still remain after sample cleanup. In the present work we describe a gas chromatography/tandem mass spectrometry (GC/MS/MS) method for the rapid and reliable quantification of alkylresorcinols in erythrocyte samples. The performance of the GC/MS/MS method is compared with that of GC/MS. The main characteristics of the method are: lower limits of detection: 2–10 µg/L standard solution; lower limits of quantification: 6–30 µg/L standard solution; linearity coefficients: 0.9611–0.9888; linear ranges: 2–20 µg/L in erythrocytes; and intra‐day precisions (n = 6): 4–13% at endogenous analyte levels in non‐spiked erythrocytes. Tandem mass spectrometry showed greatly improved selectivity over single‐stage mass spectrometry in the case of erythrocyte samples, eliminating all interferences detectable in single‐stage MS and enabling simple peak integration for quantification. Moreover, increased selectivity resulted in GC separation speeded up by a factor of two, allowing the duplicate analysis of over 40 samples per day. This GC/MS/MS method is suggested as an improved alternative to GC/MS for the quantification of alkylresorcinols in erythrocytes for assessing wholegrain wheat and rye intake. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

9.
The application of inductively coupled plasma--time-of-flight mass spectrometry for the speciation analysis of organolead compounds in environmental waters is described. Construction of the transfer line was achieved by means of a relatively simple and rapid coupling procedure. Derivatization of the ionic lead species was achieved by in-situ propylation with sodium tetrapropylborate; simultaneous extraction of the derivatized compounds in hexane was followed by separation and detection by capillary gas chromatography hyphenated to inductively coupled plasma-time-of-flight mass spectrometry. Detection limits for the different organolead species ranged from 10 to 15 fg (as Pb), corresponding to procedural detection limits between 50 and 75 ng L(-1), on the basis of a 50 mL snow sample, extraction with 200 microL hexane, and subsequent injection of 1 microL of the organic extract on to the column. The accuracy of the system was confirmed by additional analysis of the water samples by capillary gas chromatography coupled with microwave-induced plasma-atomic-emission spectrometry and the analysis of a standard reference material CRM 605 (road dust) with a certified content of trimethyllead.  相似文献   

10.
The highly qualified primary method of species-specific isotope dilution analysis has been employed in this work to evaluate for the first time the levels of butyltin compounds in the estuary of the river Eo (Northwest Spain) where there is, since many years, a high oyster farming activity. A spike solution containing mono-, di- and tributyltin enriched in 119Sn allowed the simultaneous determination of the three compounds in different marine environmental and biological samples collected in this area (seawater samples, sediments and biological tissues of four different marine species). The results obtained in this work showed toxic TBT levels for many marine species in 45% of the seawater samples analyzed whereas significant organotin concentrations were found to be obtained only in one of the sediments analyzed. On the other hand, TBT levels ranging from 20 to almost 200 ng g− 1 (dry weight) were obtained in the different biological tissues analyzed demonstrating the bioaccumulation of organotin compounds in certain marine species.  相似文献   

11.
12.
A chiral packed-column supercritical fluid chromatographic (pSFC) system coupled to tandem mass spectrometer (MS/MS) for the rapid measurements of (R,S)-propranolol and (+/-)-pindolol in metabolic stability samples was developed. The effects of the eluent flow rates and compositions, as well as of the nebulizer temperature, on the chromatographic performance and the ionization efficiency of the analytes in positive ion mode under pSFC conditions were studied. The ionization mechanism of the analytes in the CO2/methanol atmospheric pressure chemical ionization (APCI) environments with or without the use of an additive was studied. The chiral pSFC-APCI-MS/MS approach requiring approximately 2 min per sample was applied for the simultaneous determination of two pairs of racemic drugs in in vitro samples at low nanogram per milliliter concentrations.  相似文献   

13.
A sensitive, efficient, high throughput, direct injection bioanalytical method based on a single column and high-performance liquid chromatography (HPLC) with tandem mass spectrometry (MS/MS) was developed for pharmacokinetic analysis of early drug discovery compounds in plasma samples. After mixing with a working solution containing an internal standard each plasma sample was directly injected into a polymer-coated mixed-function column for sample cleanup, enrichment and chromatographic separation. The stationary phase incorporates hydrophilic polyoxyethylene groups and hydrophobic groups to the polymer-coated silica. This allows proteins and macromolecules to pass through the column due to restricted access to the surface of the packing while retaining the drug molecules on the bonded hydrophobic phase. The analytes retained in the column with a largely aqueous liquid mobile phase were then chemically separated by switching to a strong organic mobile phase. The column effluent was diverted from waste to the mass spectrometer for analyte detection. Within 200 plasma sample injections the response ratio (analyte vs. internal standard, %CV = 4.6) and the retention times for analyte and internal standard were found consistent and no column deterioration was observed. The recoveries of test compound in various plasma samples were greater than 90%. The total analysis time was 相似文献   

14.
The Lewis x structure [Lex, Galbeta1-4(Fucalpha1-3)GlcNAc] motif is one of the tumor antigens and plays an important role in oncogenesis, development, cellular differentiation and adhesion. The detection of Lex-carbohydrates and their structural analysis are necessary to clarify the role of Lex in several biological events. Mass spectrometry has been preferably used for the structural analysis of carbohydrates. Especially, collision-induced dissociation (CID) tandem mass spectrometry (MS/MS), which causes a glycosidic bond cleavage, is used for carbohydrate sequencing. However, Lex cannot be identified by MS/MS due to the existence of the positional isomers, such as Lewis a [Galbeta1-3(alpha1-4Fuc)GlcNAc]. In the present study, we demonstrate the specific detection of Lex-carbohydrates in a biological sample by using multiple-stage MS/MS (MSn). Using pyridylaminated oligosaccharides bearing Lex, we found that the Lex-motif yields a cross-ring fragment by the cleavage of a bond between C-3 and C-4 of GlcNAc in Gal(Fuc)GlcNAc. The Lex-specific cross-ring fragment ion at m/z 259 was effectively detected by sequential scans, consisting of a full MS1 scan, data-dependent CID MS2 scan, MS3 of [Gal(Fuc)GlcNAc+Na]+ at m/z 534, and MS4 of [GalGlcNAc+Na]+ at m/z 388. The sequential scan was applied to N-linked oligosaccharide profiling using a LC/ESI-MSn system equipped with a graphitized carbon column. We successfully detected the Lex-motif and elucidated the structures of several Lex and Lewis y [(Fucalpha1-2)Galbeta1-4(Fucalpha1-3)GlcNAc] oligosaccharides in the murine kidney used as a model tissue. Our method is expected to be a powerful tool for the specific detection of the Lex-motif, and structural elucidation of Lex-carbohydrates in biological samples.  相似文献   

15.
P-Glycoprotein (P-gp/ABCB1) is expressed in membrane barriers to exclude pharmacological substrates from cells, and therefore influences the ADME/Tox properties and efficacy of therapeutics. In the present study, a liquid chromatography/tandem mass spectrometry (LC/MS/MS)-mediated targeted proteomics was developed to quantitate P-gp protein. With the aid of in silico predictive tools, a unique 9-mer tryptic peptide of P-gp protein was synthesized (with the stable isotope labeled (SIL) peptide as internal standard) and applied for quantitative LC/MS/MS method development. For LC/MS/MS quantification, the N-glycosylation of the peptide, polymorphism and transmembrane region was intended to be excluded during the peptide selection. The lower limit of quantification was established to be 0.025 nM with the linearity of the standard curve ranging to 20 nM of P-gp signature peptides in the matrix digested surrogate bovine serum albumin. The digestion efficiency, both the accuracy (relative error) and the precision (coefficient of variation) of the method, was verified by using the synthetic quantification peptide and the synthetic surrogate substrate peptide that mimics the sequence of tryptic peptide and associated flanking tryptic cleavage sites at the N- and C-terminals. By applying the method developed, the absolute amounts of human, dog and mouse P-gp (Mdr1a) were quantified in various biological samples. LC/MS/MS-mediated P-gp quantification was achieved as a highly sensitive, selective and reproducible assay and could be directly applicable to many current research needs related to P-gp.  相似文献   

16.
Isoniazid and ethambutol are commonly used in various combination treatments for tuberculosis, and for this reason a rapid and sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method was developed and validated for simultaneous quantification of these two drugs in human plasma. After a simple protein precipitation using methanol, the analytes and the internal standard metformin were chromatographed on a C18 column and detected by MS/MS. An atmospheric pressure chemical ionization interface was chosen to reduce ion suppression from sample matrix components and provide high sensitivity. The LC retention times for isoniazid and ethambutol were 2.46 and 2.27 min, respectively. The method was linear in the concentration range of 10.0-5000 ng/mL for each analyte using 100 microL plasma. The intra- and inter-day precisions, expressed as the relative standard deviation (RSD), were less than 5.7 and 6.4%, determined from QC samples for isoniazid and ethambutol, and the accuracies were within +/-2.1% and +/-4.5% in terms of relative error, respectively. The method was successfully employed in a pharmacokinetic study after oral administration of a multicomponent formulation containing 150 mg isoniazid, 500 mg ethambutol, 150 mg rifampicin and 250 mg pyrazinamide.  相似文献   

17.
Summary Turbulent flow chromatography coupled to tandem mass spectrometry (TFC-MS-MS) has recently emerged as a potentially fast, sensitive and specific technique for the direct analysis of pharmaceutical compounds from crude plasma. TFC-MS-MS removes the need for time-consuming sample preparation procedures such as solid-phase extraction (SPE) or liquid-liquid extraction (LLE). A relatively high flow rate combined with the use, of an HPLC column with large porous particles allows the on-line clean up and quantification of compounds in plasma samples. Until, now, the amount of plasma directly injected into TFC systems has rarely exceeded 30 μL in order to prevent rapid column degradation. Increasing the injection volume also induces high carry-over levels, particularly for drugs with basic and/or lipophilic properties. This paper describes the first genetic TFC-MS-MS method developed in a 96-well format, which allows the direct injection of 200 μL of 1∶1 diluted plasma (equivalent to 100 μL neat plasma). An average, of 390 injections was carried out with each extraction column. More than 2000 dog plasma samples were injected into the system without any sign of carryover. The method was fully validated over a 5–500 ng mL−1 range for three basic compounds: doxazosin, CP122,288 and dofetilide. The imprecision was 1.2 to 8.3% for doxazosin, 1.5 to 4% for CP122,288 and 1.6 to 9.2% for dofetilide. The inaccuracy ranged from 6% to 7.9%. This generic methodology was then used to assay two structurally unrelated development compounds, showing that the method accuracy and sensitivity were adequate for the early pharmacokinetic (PK) studies in animals.  相似文献   

18.
This work presents two liquid chromatography/tandem mass spectrometry (LC/MS/MS) acquisition modes: multiple reaction monitoring (MRM) and neutral loss scan (NL), for the analysis of 28 compounds in a mixture. This mixture includes 21 compounds related to the metabolism of three amino acids: tyrosine, tryptophan and glutamic acid, two pterins and five deuterated compounds used as internal standards. The identification of compounds is achieved using the retention times (RT) and the characteristic fragmentations of ionized compounds. The acquisition modes used for the detection of characteristic ions turned out to be complementary: the identification of expected compounds only is feasible by MRM while expected and unexpected compounds are detected by NL. In the first part of this work, the fragmentations characterizing each molecule of interest are described. These fragmentations are used in the second part for the detection by MRM and NL of selected compounds in mixture with and without biological fluids. Any preliminary extraction precedes the analysis of compounds in biological fluids.  相似文献   

19.
An in-depth study of the reproducibility of data acquired for comparative proteomics analysis using a prototype two-stage heated laminar flow chamber fitted to a commercial high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) instrument was undertaken. The study is based on 24 replicate samples from four independent membrane preparations derived from two matched breast cancer cell lines. Variation and reproducibility in the data were evaluated at several levels highlighting the relative efficiency and variability of the acquisition routines used. Specifically, variation in the number and relative intensities of chromatographic peaks eluted from the LC column, precursor ion selection and sequence identification were evaluated. On average, approximately 6500 chromatographic peaks were generated for each acquisition with a corresponding coefficient of variance (CV) of less than 20%. Precursor ion selection and sequence identification averaged 1380 and 780 events per acquisition sample, respectively, with corresponding CVs of less than 10% for each. The reproducibility in the precursor ion selection was typically better than 60% between similar replicates. Using protein and peptide internal standards, it was found that the CV in retention time across the gradient between two acquisition pairs was typically less than 5%, whereas the average intensity ratio was 1.0 (expected) with a CV approaching 20%. An evaluation of the intensity ratios calculated from endogenous peptide sequences, identified across the acquisition set, indicated a CV of approximately 30%. Similarly, the CV associated with the top 1000 peptides indicated a mean and median of 28.4 and 26.95%. For a given acquisition pair it was also found that approximately 11% of the chromatographic peaks eluting from the column were linked to a sequence or identified. For these experiments, less than 10% of the peak pairs had absolute ratios greater than 2.0 and of those only approximately 10% had sequences linked to them. For each matched acquisition set on average 406 proteins were identified with a CV of less than 10%. Of the proteins that were identified approximately 30% had at least one predicted trans-membrane domain, indicating a four-fold increase over a crude homogenate sample with only minor enrichment. During these experiments it was found that the interface did not significantly alter the relative charge state distribution of ions, nor did it introduce significant interference from background ions. The interface was capable of 24-hour acquisition cycles.  相似文献   

20.
High-performance liquid chromatography (HPLC) combined with inductively coupled plasma mass spectrometry (ICPMS) has been studied as a means for the detection of carbon to provide a 'universal' method for detecting organic compounds in chromatographic eluents. Carbon is particularly difficult to ionise and the amount of carbon present in normal chromatographic systems leads to high backgrounds, making detection a challenge. Novel separation approaches were therefore employed, using either entirely aqueous eluents (at temperatures of 60 and 160 degrees C, dependent on the column used) to eliminate the organic modifier completely, or isotopically enriched solvents. For the aqueous eluents, detection limits for sulphanilamide were found to be 2.26 microg, corresponding to 1.13 micromol (0.47 micromol of carbon), injected on a conventional 4.6 mm i.d. column. The use of a narrow bore column with highly isotopically enriched 12C-methanol (99.95 atom%) as organic modifier for the mobile phase enabled the detection of 86 micromol for 13C-triple-labelled caffeine and 79 micromol for 13C-double-labelled phenacetin. The sensitive detection of 12C-compounds with 13C-enriched methanol as organic modifier proved impractical due to a lower level of isotopic enrichment (99 atom%) of this solvent, with the residual 12C-methanol resulting in significant interference.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号