首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
On-capillary chemiluminescence detection for capillary electrophoresis with a single capillary was reported. A hole (about 30 microm diameter) was made on the capillary wall at about 50.5 cm from the inlet end. Hydrogen peroxide solution could enter the capillary from the hole, and mixed with luminol and copper(II) to produce chemiluminescence. The chemiluminescence was detected by a PMT under the hole. Several factors that influenced chemiluminescence intensity were investigated. The detection limits for luminol and N-(4-aminolbutyl)-N-ethylisoluminol (ABEI) were 1 x 10(-11) and 2 x 10(-10) mol L(-1), respectively. The method features simple construction and no dead volume.  相似文献   

2.
Chemiluminescence detection was used in capillary electrophoresis integrated on a microchip. Quartz microchips have two main channels and four reservoirs. Dansyl-lysine and -glycine were separated and detected with bis[(2-(3,6,9-trioxadecanyloxycarbony)-4-nitrophenyl]oxalate as peroxyoxalate chemiluminescent reagent. These dansyl amino acids came into contact with the chemiluminescence reagent to produce visible light at the interface between the separation channel and chemiluminescence reagent-containing reservoir. The detection limit (S/N = 3) for dansyl-lysine was 1 x 10(-5) M, which corresponded to the very small mass detection limit of ca. 0.4 fmol. However, the concentration sensitivity in the present system was approximately two orders of magnitude lower than that in the conventional capillary electrophoresis-chemiluminescence detection system. The relative standard deviations of migration time and peak height for dansyl-lysine were 4.2 and 4.5%, respectively. A channel conditioning before every run and an appropriate control of voltages were needed for the reproducible results. The present system had advantages in rapid separation time (within 40 s), small (several 10 pI) and accurate sample injection method using a cross-shaped injector, and simplification and miniaturization of the detection device.  相似文献   

3.
A rapid and simple method using capillary electrophoresis (CE) with chemiluminescence (CL) detection was developed for the determination of levodopa. This method was based on enhance effect of levodopa on the CL reaction between luminol and potassium hexacyanoferrate(III) (K3[Fe(CN)6]) in alkaline aqueous solution. CL detection employed a lab-built reaction flow cell and a photon counter. The optimized conditions for the CL detection were 1.0 × 10−5 M luminol added to the CE running buffer and 5.0 × 10−5 M K3[Fe(CN)6] in 0.6 M NaOH solution introduced postcolumn. Under the optimal conditions, a linear range from 5.0 × 10−8 to 2.5 × 10−6 M (r = 9991), and a detection limit of 2.0 × 10−8 M (signal/noise = 3) for levodopa were achieved. The precision (R.S.D.) on peak area (at 5.0 × 10−7 M of levodopa, n = 11) was 4.1%. The applicability of the method for the analysis of pharmaceutical and human plasma samples was examined.  相似文献   

4.
Indirect detection of paracetamol was accomplished using a capillary electrophoresis-chemiluminescence (CE-CL) detection system, which was based on its inhibitory effect on a luminol-potassium hexacyanoferrate(III) (K3[Fe(CN)6]) CL reaction. Paracetamol migrated in the separation capillary, where it mixed with luminol included in the running buffer. The separation capillary outlet was inserted into the reaction capillary to reach the detection window. A four-way plexiglass joint held the separation capillary and the reaction capillary in place. K3[Fe(CN)6] solution was siphoned into a tee and flowed down to the detection window. CL was observed at the tip of the separation capillary outlet. The CL reaction of K3[Fe(CN)6] oxidized luminol was employed to provide the high and constant background. Since paracetamol inhibits the CL reaction, an inverted paracetamol peak can be detected, and the degree of CL suppression is proportional to the paracetamol concentration. Maximum CL signal was observed with an electrophoretic buffer of 30 mM sodium borate (pH 9.4) containing 0.5 mM luminol and an oxidizer solution of 0.8 mM K3[Fe(CN)6] in 100 mM NaOH solution. Under the optimal conditions, a linear range from 6.6 × 10−10 to 6.6 × 10−8 M (r = 0.9999), and a detection limit of 5.6 × 10−10 M (signal-to-noise ratio = 3) for paracetamol were achieved. The relative standard deviation (R.S.D.) of the peak area for 5.0 × 10−9 M of paracetamol (n = 11) was 2.9%. The applicability of the method for the analysis of pharmaceutical and biological samples was examined.  相似文献   

5.
毛细管电泳与化学发光检测联用方法的研究进展   总被引:1,自引:0,他引:1  
易方  黄香宜  任吉存 《色谱》2017,35(1):110-120
毛细管电泳由于其超高的分离效率广泛应用于生物医药、环境监测、食品科学以及公共安全等领域。然而,由于毛细管电泳具有进样量较少、检测光程较短等缺点,需要与高灵敏度检测器联用实现低浓度样品的分析。化学发光检测由于其背景信号低而具有超高的灵敏度。毛细管电泳-化学发光检测联用方法将毛细管电泳的高效分离特性与化学发光检测的高灵敏性相结合,成为一种非常重要的分析方法,广泛用于化学分析、药物筛选以及环境监测等领域。该文对近年来毛细管电泳-化学发光检测联用方法的基本原理进行概述,并对其发展趋势和应用前景进行了展望。  相似文献   

6.
Ji X  He Z  Ai X  Yang H  Xu C 《Talanta》2006,70(2):353-357
A competitive immunoassay for clenbuterol (CLB) based on capillary electrophoresis with chemiluminescence (CL) detection was established. The method was based on the competitive reaction of horseradish peroxidase (HRP)-labeled CLB (CLB-HRP) and free CLB with anti-CLB antiserum. The factors affecting the electrophoresis and CL detection were systematically investigated with HRP as a model sample. Under the optimal conditions, the tracer CLB-HRP and the immunoassay complex were separated, and the linear range and the detection limit (S/N = 3) for CLB were 5.0-40 nmol l−1 and 1.2 nmol l−1, respectively. The proposed method has been applied satisfactorily in the analysis of urine sample.  相似文献   

7.
A rapid and simple method is presented for the determination of folic acid (FA) by capillary electrophoresis (CE) with chemiluminescence (CL) detection. This method was based on enhance effect of FA on the CL reaction between luminol and BrO(-) in alkaline aqueous solution. Optimal separation and determination was obtained with an electrophoretic buffer of 35 mM sodium borate (pH 9.4) containing 0.8 mM luminol, and an oxidizer solution of 1.6 mM NaBrO in 100 mM NaCO(3) buffer solution (pH 12.0). Under the optimal conditions, the determination of FA was achieved in less than 20 min, and the detection limit was 2.0 x 10(-8) M (S/N=3). The relative standard deviations (RSDs) on peak area and migration time were in the 1.5 and 1.1%, respectively. The present CE-CL method was applied to the determination of FA in commercial pharmaceutical tablets, apple juices and human urine.  相似文献   

8.
We developed a capillary electrophoresis with chemiluminescence detection system using 2-methyl-6-p-methoxyphenylethynylimidazopyrazinone as a chemiluminescence reagent for determination of antioxidants of superoxide anions. 2-Methyl-6-p-methoxyphenylethynylimidazopyrazinone reacted with superoxide anions generated through the reaction of hypoxanthine and xanthine oxidase, and then emitted chemiluminescence. Suppression of the chemiluminescence in the presence of antioxidants for superoxide anions was introduced as a detection principle for antioxidants into the capillary electrophoresis with chemiluminescence detection system. After optimizing the analytical conditions, various antioxidants, such as superoxide dismutase, nitroblue tetrazolium, ascorbic acid, and catechin, were subjected to the present system. They gave negative peaks due to the quenching effect; the detection limits of superoxide dismutase, nitroblue tetrazolium, ascorbic acid, and catechin were 1, 100, 100, and 10 μM, respectively (S/N = 2). A model sample consisting of superoxide dismutase and nitroblue tetrazolium was satisfactorily separated and detected within ca. 10 min. We also applied the present system to analysis of catechin in green tea as a real sample.  相似文献   

9.
10.
A methodology for multi-class pesticide determination at trace level in lanolin is presented. Gel permeation chromatography on a Bio-Beads SX-3 column followed by a dual GC chromatographic determination has been developed. The effluent of the analytical column (50% diphenyl–methyl- or 14% cyanopropyl–phenylpolysiloxane) was split into an electron-capture and a nitrogen–phosphorus detection system. The chromatographic system was optimised for 28 pesticides commonly used to control sheep pests and corresponding to organochlorine, organophosphorus and pyretroid classes. Identification has been carried out by gas chromatography coupled to negative chemical ionization mass spectrometry. Recoveries ranged from 72 to 94% and the detection limits from 20 to 97 ng/g depending on the pesticide class, the RSDs were below 10%. Finally, the developed analytical methodology has been successfully applied to the determination of pesticides in several lanolin samples.  相似文献   

11.
毛细管电泳-化学发光法测定人血清中的异烟肼   总被引:2,自引:0,他引:2  
基于碱性介质中异烟肼对laminol-K3Fe(CN)6化学发光体系的增敏作用,设计了一个经毛细管电泳(CE)分离,在线化学发光检测异烟肼的新方法.研究并优化了毛细管电泳分离及化学发光检测的条件.在优化的实验条件下,该方法测定异烟肼的线性范围为4.0×10-7~1.0×10-5g/mL(R2=0.9984),检出限(3σ)为1×10-8g/mL,对6.0×10-6g/mL的异烟肼进行6次平行测定,其相对标准偏差为4.0%.方法已用于血清中异烟肼的测定.  相似文献   

12.
A sensitive capillary electrophoresis (CE) method with chemiluminescence (CL) detection was developed for the determination of homocysteine (HCys) in human plasma. In this work, N‐(4‐aminobutyl)‐N‐ethylisoluminol was used as tagging reagent to label the analyte for achieving high assay sensitivity. N‐(4‐Aminobutyl)‐N‐ethylisoluminol‐tagged HCys after CE separation reacted with hydrogen peroxide in the presence of horseradish peroxidase, producing CL emission. Experimental conditions for labeling analyte, CE separation, and CL detection were studied. The CL intensity was proportional to the concentration of HCys in the range of 2.5×10?8 to 5.0×10?6 M. Detection limit (S/N=3) was 7.6×10?9 M. Human plasma samples from healthy donors were analyzed by the presented method. HCys levels were found to be in the range of 9.50–15.3 μM.  相似文献   

13.
A sensitive method for the simultaneous determination of chromium(III) (Cr3+) and chromium(VI) (CrO4(2-)) using in-capillary reaction, capillary electrophoresis (CE) separation and chemiluminescence (CL) detection was developed. The chemiluminescence reaction was based on luminol oxidation by hydrogen peroxide in basic aqueous solution catalyzed by Cr3+ ion followed by capillary electrophoresis separation. Based on in-capillary reduction, chromium(VI) can be reduced by acidic sodium hydrogensulfite to form chromium(III) while the sample is running through the capillary. Before the electrophoresis procedure, the sample (Cr3+ and CrO4(2-)), buffer and acidic sodium hydrogensulfite solution segments were injected in that order into the capillary, followed by application of an appropriate running voltage between both ends. As both chromium species have opposite charges, Cr3+ ions migrate to the cathode, while CrO4(2-) ions, moving in the opposite direction toward the anode, react with acidic sodium hydrogensulfite which results in the formation of Cr3+ ions. Because of the migration time difference of both Cr3+ ions, Cr(III) and Cr(VI) could be separated. The running buffer was composed of 0.02 mol l(-1) acetate buffer (pH 4.7) with 1 x 10(-3) mol l(-1) EDTA. Parameters affecting CE-CL separation and detection, such as reductant (sodium hydrogensulfite) concentration, mixing mode of the analytes with CL reagent, CL reaction reagent pH and concentration, were optimized. The limits of detection (LODs) of Cr(III) and Cr(VI) were 6 x 10(-13) and 8 x 10(-12) mol l(-1) (S/N=3), respectively. The mass LODs for Cr(III) and Cr(VI) were 1.2 x 10(-20) mol (12 zmol) and 3.8 x 10(-19) mol (380 zmol), respectively.  相似文献   

14.
A novel and simple method is presented for the determination of norfloxacin, ciprofloxacin, and ofloxacin by capillary electrophoresis with chemiluminescence detection. This method is based on the enhancing effect of quinolones on the chemiluminescence reaction of the Ce(SO4)2–Ru(bpy)32+–HNO3 system. Three quinolones were successfully separated and detected under optimum conditions. The obtained detection limits were 2.3×10–7 mol/L, 5.2×10–8 mol/L, and 7.8×10–8 mol/L for ciprofloxacin, norfloxacin, and ofloxacin, respectively. The RSD of migration time and peak area were less than 1.8 and 3.8% (n = 5), respectively. The applicability of the proposed method was illustrated in the determination of ofloxacin in eye drops and of norfloxacin in human urine samples, and the monitoring of pharmacokinetics for norfloxacin.  相似文献   

15.
Liu H  Han N  Zhang L  Du Y  Zhang W 《Analytica chimica acta》2010,680(1-2):48-53
A dynamic coating capillary electrophoresis coupled with a simplified on-line chemiluminescence detection system was designed and evaluated. In the proposed system, poly-vinylpyrrolidone was used as dynamic coating substance in the separation buffer to reduce the unwanted protein non-specific adsorption, which was first applied in capillary electrophoresis coupling with on-line chemiluminescence detection. In order to avoid complex processing, an ordinary plastic cuvette was modified as a three-way joint. The chemiluminescence reaction conditions and capillary electrophoresis separation conditions were investigated in detail. The results showed that the coated capillary can be injected protein samples at least 30 times continuously with good repeatability. Under optimal conditions, the chemiluminescence relative intensity was linear with the concentration of hemoglobin in the range of 4-1850 μg mL(-1) and the detection limit was 2.0 μg mL(-1) (S/N=3). The relative standard deviation of migration times and peak heights for 40 μg mL(-1) hemoglobin were 2.5% and 4.1% (n=11) respectively. Interference of matrix effects was overcome by the calibration according to standard addition methods. Afterwards, the method was validated successfully and was applied to detect the concentration of hemoglobin in the serum of haemolytic patients.  相似文献   

16.
Ultrasensitive chemiluminescence (CL) detection of aM vanadium(IV) in capillary electrophoresis (CE) is first reported. In this work, inclusion of the luminol in the electrophoretic carrier electrolyte avoids the loss of light signal that occurs when luminol and hydrogen peroxide are mixed in advance, as in the conventional method in CE-CL detection. The detection limit (S/N ratio=3) for V(IV) is 2.4×10−17 M (24 aM), which has been improved by a factor of 104 as compared with that of the most sensitive metal ion detection (Co2+ 0.5 pM) reported previously. In addition, the separation of V(IV) and V(V) has been performed successfully.  相似文献   

17.
A CE instrument coupled with chemiluminescence (CL) detection was designed for the determination of promethazine hydrochloride (PTH) and promazine hydrochloride (PMH) in real samples. An important enhancement of the CL emission of luminol with potassium ferricyanide was observed in the presence of these phenothiazines; so this system was selected for their detection after CE separation. Parameters affecting the electrophoretic separation were optimized in a univariate way, while those affecting CL detection were optimized by means of a multivariate approach based on the use of experimental designs. Chemometrics was also employed for the study of the robustness of the factors influencing the postcolumn CL detection. The method allows the separation of the phenothiazines in less than 4 min, achieving LODs of 80 ng/mL for PMH and 334 ng/mL for PTH, using sample injection by gravity. Electrokinetic injection was used to obtain lower LODs for the determination of the compounds in biological samples. The applicability of the CE-CL method was illustrated in the determination of PTH in pharmaceutical formulations and in the analysis of PMH in human urine, using a previous SPE procedure, achieving an LOD of 1 ng/mL and recoveries higher than 85%.  相似文献   

18.
An aptamer-based label-free approach to hemin recognition and DNA assay using capillary electrophoresis with chemiluminescence detection is introduced here. Two guanine-rich DNA aptamers were used as the recognition element and target DNA, respectively. In the presence of potassium ions, the two aptamers folded into the G-quartet structures, binding hemin with high specificity and affinity. Based on the G-quartet–hemin interactions, the ligand molecule was specifically recognized with a K d ≈ 73 nM, and the target DNA could be detected at 0.1 μM. In phosphate buffer of pH 11.0, hemin catalyzed the H2O2-mediated oxidation of luminol to generate strong chemiluminescence signal; thus the target molecule itself served as an indicator for the molecule–aptamer interaction, which made the labeling and/or modification of aptamers or target molecules unnecessary. This label-free method for molecular recognition and DNA detection is therefore simple, easy, and effective. Figure A label-free approach to aptamer-based hemin recognition and DNA detection is introduced, which gives great potential for using a small molecule itself as the indicator for molecular recognition and DNA detection thereby avoiding any labeling or modification step  相似文献   

19.
Chemiluminescence (CL) offers a sensitive detection method for capillary electrophoresis (CE), but the implementation of CE–CL is usually under compromised operating conditions for CE, such as the prerequisite of extreme pH buffer for optimal CL reaction at the capillary outlet. This has sometimes significantly deteriorated the separation of CE. In this study, the development of a new interface makes it possible to optimize the operating conditions for CE separation and CL detection independently. The interface consists of an on-column fracture being installed in a reservoir near the capillary end to create an electrical connection and also serve as reagent addition entrance. The capillary terminal is inserted into an end-column reservoir for CL reaction and detection. In this arrangement, the applied electric field has been decoupled from the CL detection, which is proved to effectively improve CE's performance by allowing the use of optimal CE buffers. At the same time, it enables the optimization of CL detection independently. The applicability of this interface was evaluated by using acridinium ester (AE) and luminol systems. For AE system, the interfering products of CL reagent (OH, HO2) have been prevented, and the pH range of CE buffer can be independent to the optimal pH value of AE CL reaction, which is usually below 3. The AE was detected using running buffer at pH 8.7, giving a detection limit of 0.1 nM (S/N = 3), and the theoretical plate numbers is as high as 56 000. The on-column fracture based configuration is simple, sensitive and easy to implement.  相似文献   

20.
Peak areas, peak heights, and apparent theoretical plate numbers were examined as a function of sample injection times by use of the batch-type CL detection cell. Comparing the experimental data with those obtained by absorption detector, some considerations were carried out about the peak shape. The peak shape in CL detection was influenced by not only concentration distribution of sample in a sample zone but also sample diffusion and CL reaction at the capillary outlet. The sample injection time of ca. 35 s was recommended for the present CE with CL detector. The injection time much influenced peak shape as well as sensitivity in the CL detection cell.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏