首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
A non-aqueous reversed-phase liquid chromatographic method coupled to electrospray ionisation (ESI) tandem mass spectrometry was developed for the analysis of triacylglycerols (TGs). The synthetic TGs studied were separated according to their equivalent carbon number with a gradient of methanol (containing 0.01% (v/v) formate adjusted to pH 5.3 with ammonia) and chloroform. ESI mass spectra of TGs yielded positive ion current signals for [M + NH(4)](+) and [M + NH(4)-RCOONH(4)](+). The mass spectra also showed signals believed to arise from [M + K](+). Collision-induced dissociation (CID) of the [M + NH(4)](+) precursor ion yielded [M + NH(4) - RCOONH(4)](+), [RCO + 74](+) and [RCO](+) product ions as aids for the structural elucidation of the TGs. In addition, [RCO - 18](+) and small amounts of [RCO - 2](+) product ions were also found. The latter ions were observed only for TGs containing unsaturated fatty acids. CID of ammoniated 1-stearoyl-2-oleoyl-3-linoleoyl-glycerol (18:0/18:1/18:2) indicated that neutral loss of the sn-2 fatty acid was energetically less favourable than loss of the fatty acid from the sn-1 or sn-3 position.  相似文献   

2.
Glutathione (GSH) is a tripeptide composed of glutamate, cysteine, and glycine. It is present in practically all cells and has several important roles, such as preventing the oxidation of the sulfhydryl groups of proteins within a cell. Evidence for GSH deficiency or depletion has been found in a variety of diseases and toxicity-related studies, including diabetes and induction of oxidative stress to form reactive oxygen species which cause DNA, lipid, and protein oxidations. A simple, selective, and sensitive analytical method for measuring low levels of GSH in biological fluids would therefore be desirable to conduct GSH deficiency or depletion-related mechanistic toxicity studies. Here a method for both low- and high-level quantitation of GSH from cultured cells and rat liver tissues via liquid chromatography/positive electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) has been developed. The lower limit of quantitation (LOQ) of the method was 5 ng/mL. The method is linear over a wide dynamic concentration range of 5.0 to 5000.0 ng/mL, with a correlation coefficient R2 > 0.99. The intra-day assay precision relative standard deviation (RSD) values for all quality control (QC) samples were < or =16.31%, with accuracy values ranging from 94.13 to 97.80%. The inter-day assay precision RSD values for all QC samples were < or =15.94%, with accuracy values ranging from 94.51 to 100.29%. With this method, low levels of GSH from diethyl maleate (DEM)-treated mouse lymphoma cells, and GSH in rat liver tissues, were quantified.  相似文献   

3.
Betamethasone and dexamethasone are two corticosteroids differing in the stereoisomery of their C-16 methyl group. These two compounds are imperfectly separated by reversed-phase liquid chromatography and their mass spectra are very similar, leading to a difficult unambiguous identification according to European criteria. A method is proposed for differentiating betamethasone and dexamethasone using liquid chromatography/tandem mass spectrometry and multivariate statistical analysis. Multiple analysis of variance was used for the justification and the selection of diagnostic ions. Principal component analysis permitted the suitability of the approach to be tested on a large number of samples. Discriminant factorial analysis was finally performed to build a decisional model based on the six most significant ions. This novel utilization of mass spectrometric data appeared efficient for the unambiguous identification of the target analytes in urine samples.  相似文献   

4.
Twenty proteinogenic amino acids (AAs) were determined without derivatization using flow injection analysis followed by electrospray ionization mass spectrometry and tandem mass spectrometry (ESI-MS and ESI-MS/MS) and electrospray ionization high-field asymmetric waveform ion mobility mass spectrometry and tandem mass spectrometry (ESI-FAIMS-MS and ESI-FAIMS-MS/MS), in positive and negative ionization modes. Three separate sets of ESI-FAIMS conditions were used for the separation and detection of the 20 AAs. Typically ESI-FAIMS-MS showed somewhat improved sensitivity and significantly better signal-to-noise ratios than ESI-MS mainly due to the elimination of background noise. However, the difference between ESI-FAIMS-MS and ESI-MS/MS was significantly less. ESI-FAIMS was able to partially or completely resolve all the isobaric amino acid overlaps such as leucine, isoleucine and hydroxyproline or lysine and glutamine. Detection limits for the amino acids in ESI-FAIMS-MS mode ranged from 2 ng/mL for proline to 200 ng/mL for aspartic acid. Overall, ESI-FAIMS-MS is the preferred method for the quantitative analysis of AAs in a hydrolyzed yeast matrix.  相似文献   

5.
Tomato (Lycopersicon esculentum Mill.) is the second most important fruit crop worldwide. Tomatoes are a key component in the Mediterranean diet, which is strongly associated with a reduced risk of chronic degenerative diseases. In this work, we use a combination of mass spectrometry (MS) techniques with negative ion detection, liquid chromatography/electrospray ionization linear ion trap quadrupole‐Orbitrap‐mass spectrometry (LC/ESI‐LTQ‐Orbitrap‐MS) and liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI‐MS/MS) on a triple quadrupole, for the identification of the constituents of tomato samples. First, we tested for the presence of polyphenolic compounds through generic MS/MS experiments such as neutral loss and precursor ion scans on the triple quadrupole system. Confirmation of the compounds previously identified was accomplished by injection into the high‐resolution system (LTQ‐Orbitrap) using accurate mass measurements in MS, MS2 and MS3 modes. In this way, 38 compounds were identified in tomato samples with very good mass accuracy (<2 mDa), three of them, as far as we know, not previously reported in tomato samples. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

6.
A congener-specific method based on high-performance liquid chromatography/electrospray ionization tandem mass spectrometry (HPLC/ES-MS/MS) in the negative ion mode was developed for the analysis of hexabromocyclododecane (HBCDD). On a C(18) analytical column, with a methanol/water mobile phase, the alpha-isomer was completely resolved from the beta- and gamma-isomers while the beta- and gamma-isomers were sufficiently resolved at half their peak heights. The ES spray voltage strongly influenced the intensity of the ion signal. For MS, a source temperature of 500 degrees C and a collision energy of 50 eV were found to be optimum for the [M-H](-) to Br(-) transition. Run-to-run and day-to-day (n = 3) variability was minimal, with relative standard deviations of 2.6-4.1 and 2.4-4.4%, respectively. The limit of detection was 4-6 pg on-column. When applied to tissue samples from Lake Winnipeg fish both alpha- and gamma-isomers of HBCDD were found in low-ng/g (lipid corrected) concentrations.  相似文献   

7.
8.
The analysis of several neutral drugs, mephenesin, guaifenesin, simvastatin, podophyllotoxin and inositol, was accomplished by negative ion electrospray ionization mass spectrometry (ESI-MS) using adduct formation with three different halide ions. The fluoride, chloride and bromide adducts of the selected drugs exhibited intense signals in negative ion ESI. Under collision-induced dissociation, the major product ions of bromide and chloride adducts were the nonspecific bromide and chloride anions, respectively. In contrast, fluoride adducts produced strong [M--H](-) ions as well as product ions with good intensity. Fluoride attachment liquid chromatography/negative ion electrospray tandem mass spectrometry (LC/ESI-MS/MS) was applied to the analysis of the selected neutral drugs in human plasma. Detection limits in the range of 0.025-0.05 ng/mL were achieved using 0.5 mL plasma. Good linearity was observed for each of the drugs examined in human plasma over the range of 0.05-50 ng/mL.  相似文献   

9.
Analytical methods were developed for atorvastatin, novobiocin and roxithromycin using microbore liquid chromatography/electrospray ionization tandem mass spectrometry (microbore LC/ESI-MS/MS) in positive and negative voltage switching mode. Atorvastatin and roxithromycin require the positive-ion mode, whereas the negative-ion mode is required for the determination of novobiocin. Using the positive and negative voltage switching function, the three analytes were determined with one injection, and the time required was half that required using separately run positive- and negative-ion modes, without any reduction in sensitivity. A microbore LC column (100 x 1.0 mm i.d.) was chosen for chromatographic separation with mobile phase solvents acetonitrile and 10 mM aqueous ammonium acetate. The flow-rate was 0.1 ml min(-1) and the injection volume was 1 micro l. The analytes were quantified in the multiple reaction monitoring mode with external standards. By switching the positive and negative voltage, the three analytes were determined with a 4 min chromatographic run and with instrumental detection limits of 1-3 pg. This analytical method, using a microbore LC column combined with solid-phase extraction, was applied successfully to the determination of trace levels of the above pharmaceuticals in aqueous samples. Atorvastatin was detected in a sewage treatment plant final effluent.  相似文献   

10.
The curcuminoids are a group of diarylheptanoid molecules that possess important pharmacological activities, particularly acting as anti-inflammatory agents. The main purpose of this study was to investigate the fragmentation behavior of the three major curcuminoids in ion trap liquid chromatography/tandem mass spectrometry (LC/MS/MS). Both positive and negative mode electrospray ionization in tandem and multidimensional MS(n) experiments in quadrupole ion trap instruments and high-resolution and accurate mass MS and sustained off-resonance irradiation (SORI) MS/MS experiments in a Fourier transform ion cyclotron resonance (FTICR) mass spectrometer were used to elucidate the main fragmentation channels of these compounds. These experiments yielded essentially the same fragmentation results in both ion trap and ICR instruments for all three curcuminoids and for their phenolic monoacetates. Major and diagnostic fragment ions were identified and their origins are proposed.  相似文献   

11.
Liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) is one of the most prominent analytical techniques owing to its inherent selectivity and sensitivity. In LC/ESI-MS/MS, chemical derivatization is often used to enhance the detection sensitivity. Derivatization improves the chromatographic separation, and enhances the mass spectrometric ionization efficiency and MS/MS detectability. In this review, an overview of the derivatization reagents which have been applied to LC/ESI-MS/MS is presented, focusing on the applications to low molecular weight compounds.  相似文献   

12.
13.
Prostanoids are potent mediators of many physiological and pathophysiological processes. Of the many analytical methodologies used for their qualitative and quantitative analysis, electrospray tandem mass spectrometry coupled to liquid chromatography (LC/ESI-MS/MS) offers a rapid, sensitive and versatile system applicable to lipidomic analyses. We have developed an LC/ESI-MS/MS assay for twenty-seven mediators including prostaglandins, prostacyclines, thromboxanes, dihydroprostaglandins and isoprostanes. The assay was liner over the concentration range 1-100 pg/microL. The limits of detection and quantitation were 0.5-50 and 2-100 pg, respectively, whilst recoveries were from 83-116% depending on the metabolite. The assay can be applied to the profiling of prostanoids produced by a variety of biological fluids and extracts including brain, liver, plasma and urine, thus facilitating our understanding of the role of these lipid mediators in health and disease, as well as assisting in drug development.  相似文献   

14.
A rapid analytical method based on liquid chromatography/tandem mass spectrometry (LC/MS/MS) using electrospray ionization in negative ion detection mode was developed for the analysis of underivatized iodoacetic acid in water. The method was applied to model reaction mixtures in the study of the formation of iodoacetic acid after chlorinated tap water was boiled in the presence of potassium iodide or iodized table salt. Samples can be directly analyzed by the LC/MS/MS system without extraction or chemical derivatization. Limit of detection was determined to be 0.3 microg/L (or 0.3 ng/mL) and limit of quantitation was about 1 microg/L (1 ng/mL).  相似文献   

15.
Eleven naturally occurring flavonoid aglycones, belonging to the representative flavone, flavonol, and flavanone types were separated by high performance liquid chromatography and analyzed on-line with negative ion electrospray ionization tandem mass spectrometry (ESI-MS/MS). In order to resolve the MS/MS spectra obtained, each compound was reinvestigated by direct loop injections using an ion trap mass spectrometer. The MSn spectra obtained allowed us to propose plausible schemes for their fragmentation supported by the analysis of five complementary synthetic flavonoid aglycones. The negative ion ESI-MS/MS behavior of the different aglycones investigated in this study revealed interesting differences when compared with the previously described patterns obtained using various ionization techniques in positive ion. Thus, concerning the retro Diels-Alder (RDA) fragmentation pathways, several structurally informative anions appeared highly specific of the negative ion mode. In addition, a new lactone-type structure, instead of a ketene, was proposed for a classic RDA diagnostic ion. We also observed unusual CO, CO2, and C3O2 losses which appear to be characteristic of the negative ion mode. All these results and these unusual neutral losses show that the negative ion mode was a powerful complementary tool of the positive ion mode for the structural characterization of flavonoid aglycones by ESI-MS/MS.  相似文献   

16.
A sensitive and selective method for the determination of alpha-cyclodextrin in human plasma is described using beta-cyclodextrin as an internal standard. After protein precipitation with perchloric acid, the analytes were isolated from human plasma by solid-phase extraction on Bond Elut C18 cartridges. The compounds were chromatographed on a narrow-bore aminopropyl column (125 x 2 mm i.d., 5 microm) and analyzed by electrospray ionization mass spectrometry in the positive selected-ion mode using the [M+NH4]+ ion. The lower limit of quantitation was 5 ng ml(-1) of human plasma. Linear calibration curves were obtained over the concentration range 5-1000 ng ml(-1) of human plasma. The intra- and inter-assay precisions were <18% and the accuracy was <10.5% over the entire concentration range. During the method development, the ionization efficiencies of the analytes in plasma samples originating from different sources were examined to overcome the matrix effect problems caused by co-eluting endogenous compounds. The method was successfully applied to pharmacokinetic studies in human volunteers.  相似文献   

17.
Hydrophilic interaction liquid chromatography (HILIC) is here successfully coupled to negative-ion electrospray ionization time-of-flight mass spectrometry (ESI-TOFMS) for the analysis of synthetic and chemically modified oligonucleotides. Separation was performed on a 2.1 mm × 100 mm PEEK ZIC® HILIC column packed with hydrophilic stationary phase with a permanent zwitterionic functional group and a particle size of 3.5 μm with an average pore diameter of 200 Å. A method was developed to separate homogeneous and heterogeneous oligonucleotides as well as methylated oligonucleotides using a quaternary pumping system containing ammonium acetate and water with an acetonitrile gradient. Analyses of oligonucleotides were performed by LC/MS with a detection limit of 2.5 picomole (20 mer) with signal to noise ratio (S/N) of 4.12. The influence of the eluent composition, type of buffer and its concentration, and organic modifier were also evaluated. The HILIC LC/MS method presented in this paper used common, ‘MS friendly’, mobile phases achieving sensitive and selective oligonucleotide analysis.  相似文献   

18.
Single quadrupole gas chromatography/mass spectrometry (GC/MS) has been widely used for isotopic analysis in metabolic investigations using stable isotopes as tracers. However, its inherent shortcomings prohibit it from broader use, including low isotopic precision and the need for chemical derivatization of the analyte. In order to improve isotopic detection power, liquid chromatography/electrospray ionization ion-trap tandem mass spectrometry (LC/ESI-itMS2) has been evaluated for its isotopic precision and chemical sensitivity for the analysis of [13C]palmitoylcarnitine. Over the enrichment range of 0.4-10 MPE (molar % excess), the isotopic response of LC/ESI-itMS2 to [13C]palmitoylcarnitine was linear (r = 1.00) and the average isotopic precision (standard deviation, SD) was 0.11 MPE with an average coefficient of variation (CV) of 5.6%. At the lower end of isotopic enrichments (0.4-0.9 MPE), the isotopic precision was 0.05 MPE (CV = 8%). Routine analysis of rat skeletal muscle [13C4]palmitoylcarnitine demonstrated an isotopic precision of 0.03 MPE for gastrocnemius (n = 16) and of 0.02 MPE for tibialis anterior (n = 16). The high precision enabled the detection of a small (0.08 MPE) but significant (P = 0.01) difference in [13C4]palmitoylcarnitine enrichments between the two muscles, 0.51 MPE (CV = 5.8%) and 0.43 MPE (CV = 4.6%), respectively. Therefore, the system demonstrated an isotopic lower detection limit (LDL) of < or =0.1 MPE (2 x SD) that has been impossible previously with other organic mass spectrometry instruments. LC/ESI-itMS2 systems have the potential to advance metabolic investigations using stable isotopes to a new level by significantly increasing the isotopic solving power.  相似文献   

19.
20.
A new method for simultaneous determination of amiloride and hydrochlorothiazide by liquid chromatography/electrospray tandem mass spectrometry (LC/MS/MS) operated in positive and negative ionization switching mode was developed and validated. Protein precipitation with acetonitrile was selected for sample preparation. The analytes were separated on a Phenomenex Curosil-PFP (250x4.6 mm, 5 microm) column by a gradient elution with a mobile phase consisting of 0.15% formic acid solution containing 0.23% ammonium acetate and methanol pumped at a flow rate of 1.0 mL.min(-1). Rizatriptan was used as the internal standard (IS) for quantification. The determination was carried out on a Waters Quattro-micro triple-quadrupole mass spectrometer operated in multiple reaction monitoring (MRM) mode using the following transitions monitored simultaneously: positive m/z 230-->171 for amiloride, m/z 270-->158 for rizatriptan, and negative m/z 296-->205 for hydrochlorothiazide. The lower limits of quantification (LLOQs) were 0.1 and 1.0 ng.mL(-1) for amiloride and hydrochlorothiazide, respectively, which were lower than other published methods by using ultraviolet (UV), fluorimetric or mass spectrometric detection. The intra- and inter-day precision and accuracy were studied at three different concentration levels and were always better than 15% (n=5). This simple and robust LC/MS/MS method was successfully applied to the pharmacokinetic study of compound amiloride and hydrochlorothiazide tablets in healthy male Chinese volunteers.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号