 共查询到20条相似文献,搜索用时 31 毫秒
1.
The use of a poly(methylmethacrylate) chip, provided with two separation channels in the column-coupling (CC) arrangement and on-column conductivity detection sensors, to electrophoretic separations of a group of inorganic anions (chloride, nitrate, sulfate, nitrite, fluoride and phosphate) that need to be monitored in various environmental matrices was studied. The electrophoretic methods employed in this study included isotachophoresis (ITP) and capillary zone electrophoresis (CZE) with on-line coupled ITP sample pretreatment (ITP-CZE). Hydrodynamic and electroosmotic flows of the solution in the separation compartment of the CC chip were suppressed and electrophoresis was a dominant transport process in the separations performed by these methods. ITP separations on the chip provided rapid resolutions of sub-nmol amounts of the complete group of the studied anions and made possible rapid separations and reproducible quantitations of macroconstituents currently present in water samples (chloride, nitrate and sulfate). However, concentration limits of detection attainable under the employed ITP separating conditions (2-3 x 10(-5) mol/l) were not sufficient for the detection of typical anionic microconstituents in water samples (nitrite, fluoride and phosphate). On the other hand, these anions could be detected at 5-7 x 10(-7) mol/l concentrations by the conductivity detector in the CZE stage of the ITP-CZE combination on the CC chip. A sample clean-up performed in the ITP stage of the combination effectively complemented such a detection sensitivity and nitrite, fluoride and phosphate could be reproducibly quantified also in samples containing the macroconstituents at 10(4) higher concentrations. ITP-CZE analyses of tap, mineral and river water samples showed that the CC chip offers means for rapid and reproducible procedures to the determination of these anions in water (4-6 min analysis times under our working conditions). Here, the ITP sample pretreatment concentrated the analytes and removed nanomol amounts of the macroconstituents from the separation compartment of the chip within 3-4 min. Both the ITP and ITP-CZE procedures required no or only minimum manipulations with water samples before their analyses on the chip. For example, tap water samples were analyzed directly while a short degassing of mineral water (to prevent bubble formation during the separation) and filtration of river water samples (to remove particulates and colloids) were the only operations needed in this respect.  相似文献   

2.
A new method for the determination of trace glyphosate (GLYP), non-selective pesticide, by CZE with online ITP pre-treatment of drinking waters on a column-coupling (CC) chip has been developed. CC chip was equipped with two injection channels of 0.9 and 9.9 μL volumes, two separation channels of 9.3 μL total volume and a pair of conductivity detectors. A very effective ITP sample clean-up performed in the first channel at low pH (3.2) was introduced for quick CZE resolution and detection of GLYP carried out at higher pH (6.1) in the second channel on the CC chip. The LOD for GLYP was estimated at 2.5 μg/L (15 nmol/L) using a 9.9 |mL volume of the injection channel. ITP-CZE analyses of model and real samples have provided very favorable intra-day (0.1-1.2% RSD) and inter-day (2.9% RSD) repeatabilities of the migration time for GLYP while 0.2-6.9% RSD values were typical for the peak area data. Recoveries of GLYP in spiked drinking water varied in the range of 99-109%. A minimum pre-treatment of drinking water (degassing and dilution) and a short analysis time (ca. 10 min) were distinctive features of ITP-CZE determinations of GLYP on the CC chip with high sample volume loaded, as well.  相似文献   

3.
Analytical potentialities of a chip-based CE in determination of ammonium in wastewaters were investigated. CZE with the electric field and/or ITP sample stacking was performed on a column-coupling (CC) chip with integrated conductivity detectors. Acetate background electrolytes (pH ~3) including 18-crown-6-ether (18-crown-6) and tartaric acid were developed to reach rapid (in 7-8 min) CZE and ITP-CZE resolutions of ammonium from other cations (sodium, potassium, calcium and magnesium) present in wastewater samples. Under preferred working conditions (suppressed hydrodynamic flow (HDF) and EOF on the column-coupling chip), both the employed methods did provide very good repeatabilities of the migration (RSD of 0.2-0.8% for the migration time) and quantitative (RSD of 0.3-4.9% for the peak area) parameters in the model and wastewater samples. Using a 900-nL sample injection volume, LOD for ammonium were obtained at 20 and 40 μg/L concentrations in CZE and ITP-CZE separations, respectively. Very good agreements of the CZE and ITP-CZE determinations of ammonium in six untreated wastewater samples (only filtration and dilution) with the results obtained by a reference spectrometric method indicate a very good accuracy of both the CE methods presented.  相似文献   

4.
The techniques of the on-line combination of capillary isotachophoresis with zone electrophoresis in two coupled capillaries (ITP-CZE) and a single capillary zone electrophoresis (CZE) were used for the sensitive determination of orotic acid (OA) in human urine. The simple CZE system was successfully applied for fast and reliable analyses of urine of healthy adult volunteers (the detection limit 1.7.10(-6) M OA, the total time of analysis 6 min). However, this method failed in analyses of OA in urine of ill children due to more complex matrix of the samples. Here, the ITP preconcentration and preseparation step coupled on-line with CZE proved to serve well with an electrolyte system developed and optimized for this purpose. The maximum selectivity and resolution of OA from other sample constituents in ITP-CZE was achieved by use of an electrolyte system of very low pH 2.15 both for ITP and CZE stage. The sensitivity of detection and simplicity of OA identification were enhanced by use of an external UV scanning detector. High sensitivity of ITP-CZE combination (limit of detection 3.10(-7) M OA), low sample consumption (1 microliter), good reproducibility of migration times (inter-day RSD < 1.86%) and acceptable reproducibility of the determination of OA in urine samples (average RSD = 7.27%) make this technique suitable for routine determination of trace concentration of OA especially in urine of ill children under various pathological conditions and medication.  相似文献   

5.
The combination of capillary isotachophoresis (ITP) and capillary zone electrophoresis (CZE) in the column coupling configuration was optimized in a mode where the electrolyte for the CZE step is different from the leading and terminating ITP electrolytes. Two colored markers, picric acid and 1-nitroso-2-naphthol, were used for exact timing of the transfer of isotachophoretically stacked analyte zones into the CZE column and for the control of the residual amount of the leading and terminating ITP electrolytes entering the CZE capillary together with the analytes, thus controlling the duration of transient ITP migration in the CZE capillary and ensuring good separation of the analytes and reproducibility of the migration times (relative standard deviations 1%). ITP-CZE was applied to the simultaneous assay of several cinnamic acid derivatives and flavonoids in methanolic extracts of Sambucus flowers and Crataegus leaves and flowers. The preconcentrating and cleansing effect of the ITP step allowed injection of relatively large sample volumes (30 microL). The limits of detection were approximately 20-50 ng x mL(-1) and 100 ng x mL(-1) for the acids and flavonoids, respectively ( thick similar 200-times lower compared to conventional CE) with spectrophotometric detection at 254 nm. The ITP-CZE exhibited satisfactory linearity and precision when using CZE buffer of pseudo "pH" 9.0; 1-nitroso-2-naphthol was employed as the internal standard. The separation took approximately 35 min. The ITP-CZE results for rutin, hyperoside, and vitexin-2-O"-rhamnoside were in good accordance with those obtained previously by high-performance liquid chromatography.  相似文献   

6.
An on-line preconcentration capillary electrophoresis (CE) technique, which combines a large volume sample stacking with a dynamic pH junction technique, is introduced in this paper. This dynamic pH junction with co-electroosmotic migration is formed between sodium borate pH 9.5 and sodium phosphate pH 2.5 with 150 mM sodium dodecylsulfate (SDS). A full capillary based injection allows determination of weak acidic compounds at ppb concentration levels (achieved LOD for benzoic acid was 11 nmol L(-1)). The proposed preconcentration method was compared with ITP/ITP (LOD 120 nmol L(-1)), ITP/CZE (LOD 740 nmol L(-1)) and a simple CZE method (LOD 23,330 nmol L(-1)). The analytical potential of this method was assessed with juice test samples.  相似文献   

7.
The ability of capillary zone electrophoresis (CZE) coupled on‐line with capillary isotachophoresis (ITP) sample pretreatment in the column‐coupling capillary electrophoresis equipment to separate trace enantiomers present in samples of complex ionic matrices and enantiomers present in their mixtures at significantly differing concentrations has been studied. Enantiomers of 2,4‐dinitrophenyl labeled norleucine (DNP‐Nleu) and tryptophan enantiomers were employed as model analytes in this work while urine and mixtures of tryptophan enantiomers of differing concentrations served as model samples. Experiments performed with urine samples spiked with the DNP‐Nleu racemate at sub‐μmol/L concentrations demonstrated excellent sample pretreatment capabilities of ITP (concentration of the analytes, in‐column and post‐column sample clean up) when coupled on‐line with chiral CZE separations. In the CZE separations of enantiomers present in the samples at trace concentrations the sample pretreatment could be performed in both achiral and chiral ITP electrolyte systems. The use of a chiral electrolyte system was found to be essential in the ITP pretreatment of the samples containing the enantiomers at very differing concentrations. For example, a 2×10–7 mol/L concentration of L‐tryptophan could be detected in the CZE separation stage of the ITP‐CZE combination in samples containing about a 104 excess of D‐tryptophan only when the ITP pretreatment was carried out in the electrolyte system providing the resolution of enantiomers (α‐cyclodextrin served for this purpose in the present work). A post‐column ITP sample clean up was found effective in enhancing the destacking rate of the trace enantiomer in the CZE stage when the migration configuration of the enantiomers was less favorable (the trace constituent migrating behind the major enantiomer).  相似文献   

8.
Analytical capabilities of capillary zone electrophoresis (CZE) with on-line coupled capillary isotachophoresis (ITP) sample pretreatment in the column-coupling capillary electrophoresis equipment to separate and determine enantiomers present in multicomponent ionic matrices were studied. Tryptophan was used as a model analyte in the ITP-capillary zone electrophoresis experiments performed in this context while a 90-component model mixture of UV-light absorbing organic anions and urine served as multicomponent sample matrices. Various working modes in which the on-line coupled capillary isotachophoresis-capillary zone electrophoresis combination in the column-coupling separation system can operate were employed in the anionic regime of the separation with direct injections of the samples. Advantages and limitations of these working modes in the separations of enantiomers present in model and urine matrices were assessed. Experiments with model mixtures of tryptophan enantiomers revealed that the two were resolved in the capillary zone electrophoresis stage with the aid of alpha-cyclodextrin also when their concentration ratio in the sample was 1:200 while the concentration of L(-)-tryptophan was 25 nmol/l. The limits of detection for the enantiomers were at approximately 10 nmol/l (approximately 1.5 ng/ml) concentrations for a 220 nm detection wavelength of the UV detector employed in the capillary zone electrophoresis stage and for a 30 microliters sample load. A high sample load capacity of the on-line coupled capillary isotachophoresis stage was effective in separating the samples corresponding to 3-6 microliters volumes of undiluted urine. The results from the runs with urine samples showed that only the capillary isotachophoresis-capillary zone electrophoresis combination with a post-column on-line coupled capillary isotachophoresis sample clean-up (responsible for a removal of more than 99% of the sample anionic constituents migrating in the on-line coupled capillary isotachophoresis stack and detectable in the capillary zone electrophoresis stage) provided a universal alternative for the detection and quantitation of the model analyte (L(-)-tryptophan).  相似文献   

9.
A feasibility study was performed using zone electrophoresis (ZE) coupled on‐line with isotachophoresis (ITP) sample pretreatment on a poly(methyl methacrylate) column‐coupling chip with integrated conductivity detection for direct determination of drugs in serum. Valproic acid (an antiepileptic drug), having a therapeutic range of 0.35–0.69 mmol/L (50–100 mg/L), was a test analyte while reference serum samples served as proteinaceous matrices. ITP provided in the ITP‐ZE combination a multitask sample pretreatment: (1) separation of the analyte from the serum matrix and its concentration into a narrow ITP band, (2) removal of the matrix constituents migrating in the ITP stack from the separation compartment of the chip, (3) ITP stacking of the drug released on a continuous electrophoretic decomposition of the drug‐protein complex. A high sample loadability, closely linked with the use of ITP in the first separation stage, made it possible to inject diluted serum samples with the aid of a 0.95 μL sample channel of the chip. Consequently, a 1–2 μmol/L concentration limit of quantitation for valproate from the response of the conductivity detector in the ZE stage of the combination was reached. The drug could be reliably determined in less than 10 minutes also in instances when its concentration in serum was below the lower value of the therapeutic range. 90–94% recoveries of valproate from serum samples were obtained in its direct ITP‐ZE determination when the filtration of the diluted serum (a 0.45 μm pore size filter) was the only pre‐column sample handling operation. No disturbances attributable to the precipitation of proteins from the loaded samples in the chip channels were detected.  相似文献   

10.
We explored isotachophoresis-capillary zone electrophoresis (ITP-CZE) with diode array detection on a single capillary to find out how to increase the injection volume and decrease the detection limits of aromatic sulfonates in CZE. The ITP was performed by applying a negative voltage in conjunction with hydrodynamic backpressure programming, and the terminating buffer was removed before the CZE separation, which resulted in highly sensitive determinations. The ITP increased the signal response of conventional hydrodynamic injection by a factor of 100, whereas the separation efficiency was unaffected. The limits of detection of the method were between 3 and 5 nugL(-1). The method was successfully used to determine these compounds in water samples. Experimental conditions for capillary electrophoresis-mass spectrometry were optimized and applied to determine aromatic sulfonates in water samples. These techniques enables the 2-naphthalenesulfonate to be determined in water samples.  相似文献   

11.
The present work illustrated possibilities of column coupling electrophoresis combined with ionizable chiral selector and diode array detection (DAD) for the enantioselective analysis of trace drugs (pheniramine and its analogs) in pharmaceutical and clinical samples. Isotachophoresis (ITP), on-line coupled with capillary zone electrophoresis (CZE), served as an ideal injection technique (high sample load capacity, narrow and sharp drugs zones) of on-line pretreated samples (preseparation, purification and preconcentration of drugs) for the CZE stage. Enhanced (enantio)separation selectivity of CZE with ionizable chiral selector (carboxyethyl-beta-cyclodextrin recognized between drugs enantiomers on one hand as well as between drugs and sample matrix constituents on the other hand) enabled to obtain pure zones of the drugs enantiomers, suitable for their detection and quantitation. DAD in comparison with single wavelength UV detection enhanced value of analytical information verifying purity of drugs enantiomers zones (indicating interferents with different spectra to those of drugs). Obtained results indicated pure zones of interest confirming effective ITP-CZE (enantio)separation process. Distinguishing the trace analytes signals superposed on the baseline noise was provided with sufficient reliability (for this purpose the background correction and smoothing procedure had to be applied to the raw DAD spectra). The proposed ITP-CZE-DAD methods were characterized by favorable performance parameters (sensitivity, linearity, precision, recovery, accuracy, robustness, selectivity) and successfully applied for (i) enantiomeric purity testing of dexbrompheniramine in commercial pharmaceutical tablets and (ii) enantioselective metabolic study of pheniramine in human urine.  相似文献   

12.
Bromate ion in drinking water was determined by capillary zone electrophoresis (CZE) with direct photometric detection. Bromate ion in the sample solution was introduced and concentrated into the capillary by electrokinetic injection for 50s at -10 kV. Electrophoretic separation was made at an applied voltage of -25 kV and bromate ion was detected at wavelength 193 nm, at which the baseline was stabilized with less UV-absorbing acidic phosphate buffer. Bromate ion was detected within 5 min in the electropherogram. By increasing the electric conductivity in the migrating solution with 10 mM Na2SO4, a limit of detection (LOD) of 9 x 10(-10)M (0.1 microg/L BrO3-) was achieved. The proposed method was applied to the analysis of tap water and river water samples, but bromate ion was not detected. Because the practical samples contain relatively large amount of foreign ionic substances, the tap water sample was diluted to avoid the matrix ions. Bromate ion added in a tap water at the concentration of 8 x 10(-8)M was quantitatively recovered by diluting it 1/10.  相似文献   

13.
This work deals with the determination of free sulfite in wine by zone electrophoresis (ZE) with on-line isotachophoresis (ITP) sample pretreatment on a column-coupling (CC) chip with conductivity detection. A rapid pre-column conversion of sulfite to hydroxymethanesulfonate (HMS), to minimize oxidation losses of the analyte, was included into the developed analytical procedure, while ITP and ZE were responsible for specific analytical tasks in the separations performed on the CC chip. ITP, for example, eliminated the sample matrix from the separation compartment and, at the same time, provided a selective concentration of HMS before its transfer to the ZE stage of the separation. On the other hand, ZE served as a final separation (destacking) method and it was used under the separating conditions favoring a sensitive conductivity detection of HMS. In this way, ITP and ZE cooperatively contributed to a 900 microg/l concentration detectability for sulfite as attained for a 60 nl load of wine (a 15-fold wine dilution and the use of a 0.9 microl sample injection channel of the chip) and, consequently, to the determination of free sulfite when this was present in wine at the concentrations as low as 3 mg/l. The separations were carried out in a closed separation compartment of the chip with suppressed hydrodynamic and electroosmotic flows. Such transport conditions, minimizing fluctuations of the migration velocities of the separated constituents, made a frame for precise migration and quantitation data as achieved for HMS in both the model and wine samples. Ninety percent recoveries, as typically obtained for free sulfite in wine samples, indicate promising potentialities of the present method as far as the accuracies of the provided analytical results are concerned.  相似文献   

14.
This feasibility study deals with the separations of proteins by an on-line combination of zone electrophoresis (ZE) with isotachophoresis (ITP) on a poly(methylmethacrylate) column-coupling (CC) chip with integrated conductivity detection. ITP and ZE provided specific analytical functions while performing the cationic mode of the separation. ITP served, mainly, for concentrations of proteins and its concentrating power was beneficial in reaching a low dispersion transfer (injection) of the proteinous constituents, loaded on the CC chip in a 960 nL volume, into the ZE separation stage. This was complemented by an electrophoretically driven removal of the sample constituents migrating in front of the focused proteins from the separation system before the ZE separation. On the other hand, ZE served as a final separation (destacking) method and it was used under the separating conditions providing the resolutions and sensitive conductivity detections of the test proteins. In this way, ITP and ZE cooperatively contributed to low- or sub-microg/mL concentration detectabilities of proteins and their quantitations at 1-5 microg/mL concentrations. However, a full benefit in concentration detectabilities of proteins, expected from the use of the ITP-ZE combination, was not reached in this work. Small adsorption losses of proteins and detection disturbances in the ZE stage of separation, very likely due to trace constituents concentrated by ITP, appear to set limits in the detection of proteins in our experiments. The ITP-ZE separations were carried out in a hydrodynamically closed separation compartment of the chip with suppressed hydrodynamic and electroosmotic flows of the electrolyte solutions. Such transport conditions, minimizing fluctuations of the migration velocities of the separated constituents, undoubtedly contributed to highly reproducible migrations of the separated proteins (fluctuations of the migration time of a particular protein were typically 0.5% RSD in repeated ITP-ZE runs).  相似文献   

15.
The relationships between electromigration dispersion (EMD) and on-line isotachophoresis-capillary zone electrophoresis (ITP-CZE) are described for several basic model proteins and interleukin-6 (rhIL-6). During CZE separation of the highly concentrated analyte zones which were generated during the initial ITP step EMD evolves from intrinsic differences in conductivity between the focused ITP zones and the leading electrolyte. Nearly triangular peaks with a sharp front and diffuse rear side were observed. An electromigration dispersion factor (FEMD) was introduced to measure peak asymmetry. EMD of individual peaks was shown to increase with the absolute amount of the respective analyte injected and with analyte mobility. Good linearity was observed when FEMD was plotted against protein mobility (r > 0.95). The slope of the graphs describing this relationship increased with the amount of analyte injected. The influence of EMD on the separation efficiency of neighboring peaks appeared to be less pronounced than expected. Consecutive release from the ITP-stack during transition from ITP to CZE might be an explanation for this observation.  相似文献   

16.
A poly(methylmethacrylate) chip, provided with two separation channels in the column-coupling (CC) arrangement and on-column conductivity detection sensors and intended, mainly, to isotachophoresis (ITP) and ITP-capillary zone electrophoresis (CZE) separations was developed recently. The present work was aimed at assessing its performance relevant to the detection and quantitation of the ITP analytes. Hydrodynamic (HDF) and electroosmotic (EOF) flows of the solution in the separation compartment of the CC chip were suppressed and electrophoresis was a dominant transport process in the ITP separations with model analytes carried out in this context. When the surfaces of the detection electrodes of the conductivity sensors on the chip were appropriately cleaned qualitative indices of the test analytes [relative step heights (RSHs)], provided by a particular detection sensor, agreed within 1% (expressed via RSDs of the RSH values). Their long-term reproducibilities for one sensor, as estimated from 70 ITP runs repeated in 5 days, were 2% or less. Sensor-to-sensor and chip-to-chip fluctuations of the RSH values for the test analytes were 2.5% or less. In addition, experimentally obtained RSH values agreed well with those predicted by the calculations based on the ITP steady-state model. Reproducibilities of the migration velocities attainable on the CC chips with suppressed EOF and HDF, assessed from the migration time measurements of the ITP boundary between well-defined positions on the separation channels of the chips (140 repeated runs on three chips), ranged from 1.4 to 3.3% for the migration times in the range of 100-200 s. Within-day repeatabilities of the time-based zone lengths for the test analytes characterized 2% RSDs, while their day-to-day repeatabilities were less than 5%. Chip-to-chip reproducibilities of the zone lengths, assessed from the data obtained on three chips for 100 ITP runs, were 5-8%.  相似文献   

17.
Sample pre-concentration by isotachophoresis in microfluidic devices   总被引:1,自引:0,他引:1  
We have designed microfluidic devices with the aim of coupling isotachophoresis (ITP) with zone electrophoresis (ZE) as a method to increase the concentration limit of detection in microfluidic devices. We used plastic multi-channel chips, designed with long sample injection channel segments, to increase the sample loading. The chip was designed to allow stacking of the sample into a narrow band by discontinuous ITP buffers and subsequent separation in the ZE mode. In the ITP-ZE mode, with a 2-cm long sample injection plug, sensitivity was increased by 400-fold over chip ZE and we found that the separation performance after the ITP stacking was comparable to that of regular chip ZE. We report sub-picomolar limits of detection of fluorescently labeled ACLARA eTag reporter molecules electrokinetically injected from cell lysate sample matrixes containing moderate salt concentrations. We evaluated sample injections from buffers with varied ionic strengths and found that efficient stacking and separations were obtained in both low and high conductivity buffers, including physiological buffer with at least 140 mM salt. We applied ITP-ZE to the analysis of a cell surface protease (ADAM 17) which used live intact cells in physiological buffers with detection limits below 10 cells/assay.  相似文献   

18.
We describe capillary zone electrophoresis (CZE) with transient isotachophoresis (ITP) for the determination of low concentrations of nitrite and nitrate ions in seawater. Bromide-free artificial seawater was adopted as background electrolyte (BGE) to eliminate the interference of high concentrations of salts in seawater. To reverse the electroosmotic flow (EOF), 3 mM cetyltrimethylammonium chloride (CTAC) was added to the BGE. High concentrations of chlorate were added to sample solutions as the terminating ion to generate the ITP process before the CZE separation. In general, the stacking effect increased with increasing amounts of chlorate injected into the capillary. The limits of detection (LODs) for nitrite and nitrate were 0.063 and 0.033 mg/L when the chlorate concentration was 600 and 200 mM, respectively; these were half of those obtained by CZE without the transient ITP. The LODs were obtained at a signal to noise ratio (S/N) of 3. The relative standard deviations (RSD, n = 10) of the peak areas for these ions were 3.2 and 2.9%. The RSDs of peak heights for these ions were 1.6 and 2.1%. The RSDs of migration times for these ions were 0.67 and 0.46%.  相似文献   

19.
抑制型电导检测离子色谱法测定饮用水中的痕量溴酸盐   总被引:4,自引:1,他引:3  
应波  李淑敏  岳银玲  鄂学礼 《色谱》2006,24(3):302-304
建立一种直接进样测定饮用水中痕量溴酸盐的电导检测离子色谱法。选用Metrosep A Supp 5阴离子交换分离柱,碳酸盐淋洗液。抑制型电导检测采用化学抑制器和CO2抑制器顺序双抑制系统。实验结果显示,溴酸根阴离子与常见共存阴离子完全分离,溴酸盐含量在5~100 μg/L范围内具有良好的线性(r=0.9999),精密度高(相对标准偏差(RSD)<4%),方法的检出限为0.50 μg/L,样品加标平均回收率为96.1%~107%。该方法操作简单,分离效果好,可与常见阴离子实现同时分析,灵敏度高,重现性好,可作为饮用水中溴酸盐的标准测定方法。  相似文献   

20.
Five flavonoids (hyperoside, isoquercitrin, quercitrin, quercetin and rutin) were separated and determined in extracts of Hypericum perforatum leaves or flowers by capillary zone electrophoresis (CZE) with isotachophoretic (ITP) sample pre-treatment using on-line column coupling configuration. The background electrolyte (BGE) used in the CZE step was different from the leading and terminating ITP electrolytes but all the electrolytes contained 20% (v/v) of methanol. The optimal leading electrolyte was 10 mM HCl of pH* approximately 7.2 (adjusted with Tris) and the terminating electrolyte was 50 mM H3BO3 of pH* approximately 8.2 (adjusted with barium hydroxide). This operational system allowed to concentrate and pre-separate selectively the flavonoid fraction from other plant constituents before the introduction of the flavonoids into the CZE capillary. The BGE for the CZE step was 50 mM Tris buffer of pH* approximately 8.75 containing 25 mM N-[tris(hydroxymethyl)methyl]-3-aminopropanesulfonic acid as co-ion and 55 mM H3BO3 as complex-forming agent. The ITP-CZE method with spectrophotometric detection at 254 nm was suitable for the quantitation of the flavonoids in real natural samples; kaempferol was used as internal standard. The limit of detection for quercetin-3-O-glycosides was 100 ng ml(-1) and calibration curves were rectilinear in the range 1-10 microg ml (-1) for most of the analytes. The RSD values ranged between 0.9 and 2.7% (n=3) when determining approximately 0.07-1.2% of the individual flavonoids in dried medicinal plants.  相似文献   