首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
3-(4-Methylbenzylidene)-camphor (MBC) is a chiral sunscreen agent used in cosmetic products. In this work, the enantioseparation of MBC has been performed by EKC and applied to the analysis of the MBC enantiomers in cosmetic creams. Different experimental conditions (type and concentration of the chiral selector, temperature, and sample solvent) have been optimized. Due to the neutral nature of this compound, anionic CD derivatives were investigated as chiral selectors. Carboxymethylated-beta-CD (CM-beta-CD) showed the highest chiral separation power, observing that a 15 mM concentration of this CD at a working temperature of 15 degrees C enabled to obtain the highest enantioresolution. However, under these conditions, tailing of peaks obtained for the enantiomers was observed. The addition of increasing concentrations of the neutral alpha-CD to CM-beta-CD at a 15 mM concentration in a 100 mM borate buffer at pH 9.0 improved the enantiomeric separation and decreased peak tailing. The use of DMF for the total dissolution of the cosmetic creams, and methanol:water (1:1 v/v) for appropriate dilution enabled to observe good shape and size for the peaks of the MBC enantiomers. After optimizing a method for the preconditioning of the capillary, the analytical characteristics of the chiral separation method for the analysis of MBC were investigated. Linearity, LODs and LOQs, precision (instrumental repeatability, method repeatability, intermediate precision), accuracy, and selectivity were evaluated. The method was applied to analyze MBC enantiomers contained in two commercial cosmetic creams containing racemic MBC and to study the skin absorption of this compound with time.  相似文献   

2.
A capillary electrophoresis method for the simultaneous determination of phenylglycidol enantiomers in the presence of an excess of cinnamyl alcohol was developed. The effects of the nature, pH and concentration of the buffer, the nature and concentration of chiral selector, the addition of methanol or acetonitrile, and the capillary temperature on the chiral resolution of phenylglycidol enantiomers were studied. Separations were achieved using 20 mM succinylated beta-cyclodextrin dissolved in a 10 mM borate buffer (pH 10.0). Chiral resolution for the phenylglycidol enantiomers in the optimized electrophoretic conditions was higher than 2.0 with an analysis time less than 7 min. The method developed was validated in terms of selectivity, linearity, precision (instrumental repeatability, method repeatability, intermediate precision), the limits of detection and quantitation, and accuracy. Limits of detection of 6.5 mg/L and 8.3 mg/L for (2S,3S)-(-)-3-phenylglycidol ((S,S)-PG) and (2R,3R)-(+)-3-phenylglycidol ((R,R)-PG), respectively, were obtained. The method was applied to study the asymmetric epoxidation of cinnamyl alcohol with titanium(IV) alkoxide compounds as catalysts in order to evaluate their catalytic activity and stereoselectivity of the epoxidation processes.  相似文献   

3.
Throughout the separation of chiral basic drugs by capillary electrophoresis (CE) with neutral hydroxypropyl-beta-cyclodextrin (HP-beta-CD) as chiral selector, the sensitivity of detection can be improved by using tandem mass spectrometric (MS-MS) detection with a partial filling technique rather than with UV spectrometric detection. Prior to sample injection. the capillary was partly filled with HP-beta-CD dissolved in volatile ammonium formate buffer (pH 4, ionic strength 50 mM). The effects of modifying the HP-beta-CD concentration in the selector zone and the length of the separation zone on the enantioresolution and the signal-to-noise ratio of the pseudo-molecular MH+ ion were investigated. For a given selector zone length, as the concentration of the neutral cyclodextrin increases, the resolution between enantiomers becomes higher (the opposite of the behavior of the signal-to-noise ratio) and then reaches an optimum value. The decrease of the selector zone length lowered the resolution between the enantiomers but increased peak efficiencies and signal-to-noise ratio values. Accordingly, partial capillary filling at 80% (v/v) and 10 mM concentration of HP-beta-CD was selected as a suitable compromise between resolution and sensitivity of MS detection. Limits of detection for each adrenoreceptor antagonist enantiomer were 5 ng/ml (0.02 microM) in CE-MS-MS instead of 150 ng/ml (0.60 microM) in CE-UV, which enhances sensitivity by a factor of 30.  相似文献   

4.
The simultaneous capillary electrophoretic enantioseparation of adrenergic beta(2)-agonists enantiomers (trantinterol, mabuterol, clenbuterol, bambuterol) was studied with beta-cyclodextrin, ethyl-beta-CD, methyl-beta-CD, hydroxypropyl-beta-CD, and hydroxyethyl-beta-CD as chiral selector. The type and concentration of the chiral selector and buffer pH played a very important role in the enantioseparation of the analyzed compounds. Hydroxypropyl-beta-CD was found to be the most effective complexing agent and allowed excellent chiral/achiral resolutions compared to the other CDs. The simultaneous enantioseparation of four beta(2)-agonists was achieved using 100 mM citric acid-10 mM Na(2)HPO(4) buffer at pH 2.5 containing 120 mM hydroxypropyl-beta-CD with an applied voltage of 20 kV. Method validation in terms of repeatability, linearity, and limits of detection and quantification was performed. The effect of structural features of analytes on R(s) and t(m) was studied. Complexation binding constants for the interactions between the four compounds and three different CDs were evaluated for elucidating the enantioseparation mechanism. It was found that very small differences in the chemical structure of the analytes resulted in significant changes in stereoselective recognition.  相似文献   

5.
The influences of buffer pH and the concentration of beta-cyclodextrins (beta-CDs) on the separation and migration behavior of 13 structurally related phenothiazines in CD-modified capillary zone electrophoresis (CD-CZE) using a phosphate background electrolyte at low pH were investigated. We focused on the separation of these phenothiazines, including the enantiomers of chiral analytes, with the use of beta-CD and hydroxypropyl-beta-CD (HP-beta-CD) as electrolyte modifiers or chiral selectors at concentrations less than 8 mM. The results indicate that the interactions of phenothiazines with beta-CDs are very strong and that effective separations of 13 analytes can be achieved with addition of 0.3 mM beta-CD or 0.5 mM HP-beta-CD in a phosphate buffer at pH 3.0. Binding constants of phenothiazines to beta-CDs were evaluated for a better understanding of the interactions of phenothiazines with beta-CDs.  相似文献   

6.
Chiral separation of 20 pairs of amino acids derivatized with fluoresceine-5-isothiocyanate (FITC) by capillary electrophoresis and laser-induced fluorescence detection was studied using the mixture of beta-cyclodextrin (beta-CD) and sodium taurocholate (STC) as selector. Resolution was considerably superior to that obtained by using either beta-CD or STC alone. The molar ratio of beta-CD to STC of about 2:3 was found to be critical to achieve maximum separation. At this beta-CD-to-STC ratio, chiral separation occurred at really low total concentration of beta-CD and STC (<0.1 mM). Other impacting factors were investigated including the total concentration of beta-CD and STC, pH, and capillary conditioning procedure between two successive runs. Using a running buffer of 80 mM borate containing 20 mM beta-CD and 30 mM STC at pH 9.3, all of the 20 pairs of FITC-amino acid enantiomers were baseline resolved. The resolutions of the most pairs of the amino acid enantiomers (17 of 20) were higher than 3.0, only three pairs gave a resolution lower than 3.0 but higher than 1.90 (beta-phenylserine, pSer). The highest resolution reached 14.58 (Glu). Two derivatives of beta-CD, 2-hydroxypropyl-beta-CD (HP-beta-CD) and heptakis(2,6-di-O-methyl)-beta-CD (DM-beta-CD) were also explored. HP-beta-CD showed similar cooperative effect with STC, while DM-beta-CD together with STC led to poorer chiral separation.  相似文献   

7.
A CE method using CDs as chiral selectors was developed and validated to achieve the separation of glycidyl tosylate enantiomers originated by in situ derivatization of glycidol enantiomers obtained in asymmetric epoxidation of allyl alcohol with chiral titanium‐tartrate complexes as catalysts. The effects of the nature, pH and concentration of the buffer, the nature and concentration of chiral selector, the addition of SDS, methanol, ethanol or 2‐propanol, the capillary temperature, the effective capillary length and the applied voltage on the chiral resolution of glycidyl tosylate enantiomers were investigated. The best separation conditions were achieved using a Tris‐borate buffer mixture (50 and 25 mM, respectively) at pH=9.3 with a dual CD system consisting of 2.5% succinyl‐β‐CD and 1.0% β‐CD w/v at 15°C. A baseline separation (resolution~2.0) of the glycidyl tosylate enantiomers was obtained in a relatively short time (less than 12 min). Satisfactory results were obtained in terms of linearity (r>0.99) and intermediate precision (RSD below 8.5%). The LOD and LOQ were 3.0 and 10.0 mg/L, respectively, and the recoveries ranged from 99.8 to 108.8%. Finally, the method was applied to the determination of the enantiomeric excess and the yield obtained in the asymmetric epoxidation of allyl alcohol employing chiral titanium‐tartrate complexes as catalysts after an in situ derivatization of glycidol enantiomers to glycidyl tosylate.  相似文献   

8.
《Electrophoresis》2018,39(16):2099-2106
A method consisting of cation‐selective exhaustive injection and sweeping (CSEI‐sweeping) as online preconcentration followed by a cyclodextrin modified electrokinetic chromatography (CDEKC) enantioseparation has been developed for the simultaneous determination of two brompheniramine enantiomers in rat plasma. In this method, analytes were electrokinetically injected at a voltage of 8 kV for 80 s in a fused‐silica capillary. Prior to the injection, the capillary was rinsed with 50 mM phosphate buffer of pH 3.5, followed by a plug of a higher conductivity buffer (150 mM phosphate pH 3.5, 20 psi, 6 min) and a plug of water (0.5 psi, 5 s). Separation was carried out applying –20 kV in 50 mM phosphate buffer, pH 3.5, containing 10% v/v ACN and 30 mg/mL sulfated‐β‐cyclodextrin (S‐β‐CD). Analytical signals were monitored at 210 nm. The detection sensitivity of brompheniramine enantiomers was enhanced by about 2400‐fold compared to the normal injection mode (hydrodynamic injection for 3 s at 0.5 psi, with a BGE of 50 mM phosphate buffer containing 20 mg/mL S‐β‐CD at pH 3.5), and LLOQ of two enantiomers were both 0.0100 μg/mL. In addition, this method had fairly good repeatability and showed promising capabilities in the application of stereoselective pharmacokinetic investigations for brompheniramine enantiomers in rat.  相似文献   

9.
A capillary zone electrophoresis (CZE) investigation on the enantiomeric separation of lomefloxacin, gatifloxacin, pazufloxacin and ofloxacin was undertaken. Resolution of the enantiomers was achieved using hydroxypropyl-beta-cyclodextrin (HP-beta-CD) as the chiral selector. Parameters influencing separation include cyclodextrin concentration, separational potential, pH and organic additive are discussed. A buffer consisting of 70 mM phosphate and 40 mM HP-beta-CD at pH 3.96 was found to be highly efficient for the separation of lomefloxacin, at pH 3.90 for gatifloxacin, at pH 5.04 for pazufloxacin and at pH 2.16 for ofloxacin. To the best of our knowledge, this is the first report on the enantiomeric resolution of lomefloxacin and gatifloxacin applying CE.  相似文献   

10.
The enantiomers of vildagliptin, an orally available and selective dipeptidyl‐peptidase‐4 inhibitor used for the treatment of type II diabetes, have been separated by CD‐modified CZE, using uncoated fused‐silica capillary. After screening 13 negatively charged CD derivatives as potential chiral selectors, sulfobutyl‐ether‐α‐CD (SBE‐α‐CD) was selected for the enantioseparation. For the optimization, a factorial analysis study was performed by orthogonal experimental design. Six experimental factors were chosen as variable parameters: temperature, applied voltage, chiral selector and BGE concentrations, pH, and the parameters of the hydrodynamic injection. The optimized system still was not considered final as the second peak (S‐enantiomer) migrated too close to the EOF, resulting in a potential inaccuracy during the determination of the chiral impurity. To fine‐tune the method “one factor at a time” variation approach was applied. The final method (applying 15°C capillary temperature, 40 mbar × 4 s hydrodynamic injection, 25 kV voltage in 75 mM acetate‐Tris buffer [pH 4.75] containing 20 mM SBE‐α‐CD as chiral selector) was validated according to the ICH guideline. RSD percentage of the resolution value, migration times, and corrected peak areas were below 5% during testing repeatability and intermediate precision. LOD and LOQ values were found to be 2.5 and 7.5 μg/mL, respectively. The method is considered linear in the 7.5–180 μg/mL range for the R‐enantiomer. The robustness of the method was justified using Plackett–Burmann statistical experimental design.  相似文献   

11.
Yi F  Guo B  Peng Z  Li H  Marriott P  Lin JM 《Electrophoresis》2007,28(15):2710-2716
A fast, simple, and sensitive CE method was developed to study the separation and degradation of imazaquin enantiomers in field soils. The parameters pH and concentration of the buffer electrolyte, type and concentration of the chiral selectors, applied voltage, and temperature of the CE system were investigated. Sodium hydrogen phosphate (50 mM) at pH 10.1 containing 30 mM hydroxypropyl-beta-CD (HP-beta-CD) was found to be the suitable BGE. The reliable determination for imazaquin enantiomers was obtained at 20 kV applied voltage, 15 degrees C separation system, and detection at 214 nm. Under the optimal conditions, the LODs (S/N = 3) were 0.0097 and 0.0098 mg/kg; linearity ranged from 0.019 to 1.24 and 0.020 to 1.26 mg/kg for the first-eluting peak of imazaquin (imazaquin-I) and the second-eluting peak of imazaquin (imazaquin-II) in soil, respectively. The precision in terms of the percentage of RSD (%RSD) calculated from peak area was not greater than 5%. With the suitable characteristics of the present method, it was applied to the study of enantioselective degradation in field soil. According to the calculated values of the enantiomer ratio (ER) and the rate constant of degradation (k), the results suggested that the degradation rate of the two enantiomers were slightly different, and that the pH of the soil had a strong influence on the rate of degradation.  相似文献   

12.
A new and accurate HPLC method using sulfobutylether-beta-cyclodextrin (SBE-beta-CD) as chiral mobile phase additive (CMPA) was developed and validated for the determination of R-(+)pantoprazole in S-(-)pantoprazole. The influences of type and concentration of CD, ACN content and buffer pH of mobile phase on the resolution and retention of enantiomers were investigated. A baseline resolution of pantoprazole enantiomers was achieved on a Spherigel C18 column (150 mm x 4.6 mm, 5 microm) using ACN and 10 mM phosphate buffer (pH 2.5) containing 10 mM SBE-beta-CD (15:85 v/v) as mobile phase with a flow rate of 0.9 mL/min at 20 degrees C. The detection wavelength was set at 290 nm. The method was extensively validated in terms of accuracy, precision and linearity according to the International Conference on Harmonisation (ICH) guidelines and proved to be robust. The LOD and LOQ for R-(+)pantoprazole were 0.2 and 0.5 microg/mL, respectively, with 5 microL injection volume. A good linear relationship was obtained in the concentration range of 0.5-6.0 microg/mL with r(2) >0.999 for R-(+)pantoprazole. The percentage recovery of the R-(+)pantoprazole ranged from 92.1 to 101.2 in bulk drug of S-(-)pantoprazole. The method is capable of determining a minimum limit of 0.05% w/w of R-enantiomer in S-(-)pantoprazole bulk samples.  相似文献   

13.
A practical chiral CE method, using sulfated‐β‐CD as chiral selector, was developed for the enantioseparation of glycopyrrolate containing two chiral centers. Several parameters affecting the separation were studied, including the nature and concentration of the chiral selectors, BGE pH, buffer type and concentration, separation voltage, and temperature. The separation was carried out in an uncoated fused‐silica capillary of (effective length 40 cm) × 50 μm id with a separation voltage of 20 kV using 30 mM sodium phosphate buffer (pH 7.0, adjusted with 1 M sodium hydroxide) containing 2.0% w/v sulfated‐β‐CD at 25°C. Finally, the method for determining the enantiomeric impurities of RS‐glycopyrrolate was proposed. The method was further validated with respect to its specificity, linearity range, accuracy and precision, LODs, and quantification in the expected range of occurrence for the isomeric impurities (0.1%).  相似文献   

14.
A sensitive method for enantioseparation of a basic drug rivastigmine and determination of its optical impurityby capillary electrophoresis with highly sulfated β-cyclodextrin(HS-β-CD)as the chiral selector is described.Ingeneral,enantioseparation of basic chiral compounds is carried out in acidic condition(pH 2.5)to prevent analytesfrom adsorption on the capillary wall.However,in the case of rivastigmine,the detection sensitivity was too limitedto determine the optical impurity of S-rivastigmine lower than 1% when buffer pH was 2.5.It was found that thedetection sensitivity was improved 1.6 times just by raising the buffer pH value from 2.5 to 5.8.The poor columnefficiency due to the adsorption of the analytes on the capillary wall was resolved by using dynamical coating of thecapillary wall with the linear polyacrylamide solution.The experirnental parameters such as the concentration ofHS-β-CD,buffer pH and buffer ionic strength were optimized,respectively.The method was validated in terms ofrepeatability,linearity,limit of detection(LOD)and limit of quantitation(LOQ).Using the present method,the op-tical purity of nonracemic rivastigmine with the enantiomeric excess(ee)value of 99.14% was determined.  相似文献   

15.
Micellar electrokinetic chromatography (MEKC) was successfully and conveniently applied to the chiral separation with the addition of cyclodextrins (CDs) as chiral selector to the running buffer. Chiral separation depended on the type of CD; in particular, beta-CD was effective for the chiral separation of racemorphan. We investigated the optimal conditions of type and concentration of CD as chiral selector for the routine enantiomeric separation of racemorphan with good reproducibility. The effects of other parameters such as buffer pH and detection wavelength were also investigated to obtain the optimum conditions for the enantiomeric separation of racemorphan. Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry was used for confirmation of racemorphan. The optimal conditions for enantiomeric separation of the racemorphan were as follows: 50 mM borate buffer at pH 9.4 with 50 mM SDS, 10 mM beta-CD and 20% 1-propanol, 57 cm x 50 microns fused-silica capillary column, and UV detection at 192 nm. Based on the developed method, racemorphan in human urine was also separated and determined using solid-phase extraction and MEKC.  相似文献   

16.
A capillary electrophoresis (CE) method has been developed that allows the separation and estimation of primaquine enantiomers using hydroxypropyl-gamma-cyclodextrin (HP-gamma -CD) as a chiral selector. The influence of chemical and instrumental parameters on the separation, such as type and concentration of CD, buffer concentration, buffer pH, applied voltage, capillary temperature, and injection time, were investigated. Good separation of the racemic mixture of primaquine was achieved using a fused-silica capillary (52.5 cm effective length x 50 microm id) and a background electrolyte composed of tris-phosphate buffer solution (50 mM, pH 2.5) containing 15 mM HP-gamma-CD as a chiral selector. The recommended applied voltage, capillary temperature, and injection time were 15 kV, 25 degrees C, and 6 s, respectively. Within-day and interday reproducibility of peak area and migration time gave relative standard deviation values ranging from 1.05-3.30%. Good recoveries (range of 96.8-104.9%) were obtained from the determination of placebos that were spiked with 0.25-1.00 mg/L primaquine. The proposed CE method was successfully applied to the assay of primaquine diphosphate in pharmaceutical formulations (tablets).  相似文献   

17.
The effect of several experimental parameters on enantiomeric separations in micellar capillary electrophoresis (MCE) was studied. A model separation system was tested. It was composed of an acidic phosphate buffer with sodium dodecyl sulfate (SDS) and hydroxypropyl-beta-cyclodextrin (HP-beta-CD) as the chiral selector. A substituted angelicin was used as a chiral analyte. Changes in the concentration of SDS micelles/SDS monomers in the presence of HP-beta-CD and their impact on the enantioselective separation were investigated. Variation of the composition of electrolytes in the individual compartments of the separation system (inlet vial, capillary, and outlet vial) affected both the migration times and the resolution of the enantiomers. Current vs. time dependencies also were monitored during the separations. A mathematical model of electromigration in micellar systems with chiral selector present was proposed and a computer simulation was used to explain the observed phenomena and to confirm the generation of a CD/SDS-micelle concentration gradient under certain experimental conditions. This is the reported first attempt of a computer simulation of the complex, dynamic chiral environment of the CD-SDS-MCE system.  相似文献   

18.
Novel capillary electrophoresis methods using CDs as chiral selectors were developed and validated for the chiral separation of lansoprazole and rabeprazole, two proton pump inhibitors. Fourteen different neutral and anionic CDs were screened at pH 4 and 7 in the preliminary analysis. Sulfobutyl‐ether‐β‐CD with a degree of substitution of 6.5 and 10 at neutral pH proved to be the most suitable chiral selector for both compounds. Various dual CD systems were also compared, and the possible mechanisms of enantiomer separation were investigated. A dual selector system containing sulfobutyl‐ether‐β‐CD degree of substitution 6.5 and native γ‐CD proved to be the most adequate system for the separations. Method optimization was carried out using an experimental design approach, performing an initial fractional factorial screening design, followed by a central composite design to establish the optimal analytical conditions. The optimized methods (25 mM phosphate buffer, pH 7, 10 mM sulfobutyl‐ether‐β‐CD/20 mM γ‐CD, +20 kV voltage; 17°C temperature; 50 mbar/3 s injection, detection at 210 nm for lansoprazole; 25 mM phosphate buffer, pH 7, 15 mM sulfobutyl‐ether‐β‐CD/30 mM γ‐CD, +20 kV voltage; 18°C temperature; 50 mbar/3 s injection, detection at 210 nm for rabeprazole) provided baseline separation for lansoprazole (Rs = 2.91) and rabeprazole (Rs = 2.53) enantiomers with favorable migration order (in both cases the S‐enantiomers migrates first). The optimized methods were validated according to current guidelines and proved to be reliable, linear, precise, and accurate for the determination of 0.15% distomer as chiral impurity in dexlansoprazole and dexrabeprazole samples.  相似文献   

19.
郭娜  高新星  徐国防  郭兴杰 《色谱》2008,26(2):259-261
采用C18固定相,以羟丙基-β-环糊精为手性流动相添加剂,建立了奥昔布宁对映体的高效液相色谱拆分方法。考察了手性添加剂、有机极性调节剂、缓冲盐的种类和浓度以及流动相的pH值和流速及柱温等因素对对映体分离的影响。在最佳分离条件下,奥昔布宁对映体的分离度为1.54,检测限为1.0 ng。该方法简便,重复性好,比手性固定相法更加经济。  相似文献   

20.
The application of chemical‐modified gold nanoparticles (GNPs) as chiral selector for the enantioseparation based on pseudostationary phase‐CEC (PSP‐CEC) is presented. GNPs modified by thiolated β‐CD were characterized by NMR and FT‐IR. The nanoparticle size was determined to be of 9.5 nm (+2.5 nm) by Transmission Electron Microscopy (TEM) and UV spectra. Four pairs of dinitrophenyl‐labeled amino acid enantiomers (DL‐Val, Leu, Glu and Asp) and three pairs of drug enantiomers (RS‐chlorpheniramine, zopiclone and carvedilol) were analyzed by using modified GNPs as the chiral selector in PSP‐CEC. Good theoretical plate number (up to 2.4×105 per meter) and separation resolution (up to 4.7) were obtained even with low concentration of modified GNPs (0.8–1.4 mg/mL). The corresponding concentration of β‐CD in the buffer was only 0.30?0.53 mM, which was much lower than the optimum concentration of 15 mM if pure β‐CD was used as chiral selector. Our results showed that thiolated β‐CD modified GNPs have more sufficient interaction with the analytes, resulting in significant enhancement of enantioseparation. The study shed light on potential usage of chemical modified GNPs as chiral selector for enantioseparation based on PSP‐CEC.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号