首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
A method for the direct determination of paraquat, diquat, chlormequat and difenzoquat in water samples, using an on-line solid-phase extraction-liquid chromatography-tandem mass spectrometry system was developed. No sample preparation was required and the detection limits were below the European Union maximum residue levels. The chromatographic separation was performed using an XTera MS C8 column. The concentration of the ion pair reagent, the pH and the gradient elution were optimized to give high recoveries and good chromatographic resolution between quats. The detection was carried out using an ion trap as mass analyzer. Parameters such as the magnitude and duration of the resonant excitation voltage and the magnitude of the trapping RF voltage for full scan tandem mass spectrometry (MS-MS) experiments were studied to establish the optimal experimental conditions. Moreover, the accurate optimization of these parameters allowed MS-MS experiments of low mass ions, below m/z 200, providing unambiguous peak identification. Finally, the reproducibility of the proposed method was shown by good run-to-run and day-to-day precision values and its applicability to the determination of quats in drinking water was evaluated using spiked samples.  相似文献   

2.
We have developed a simple method for extracting and purifying (+)-abscisic acid (ABA) and eight ABA metabolites - phaseic acid (PA), dihydrophaseic acid (DPA), neophaseic acid (neoPA), ABA-glucose ester (ABAGE), 7′-hydroxy-ABA (7′-OH-ABA), 9′-hydroxy-ABA (9′-OH-ABA), ABAaldehyde, and ABAalcohol - before analysis by a novel technique for these substances, ultra-performance liquid chromatography-electrospray ionisation tandem mass spectrometry (UPLC-ESI-MS/MS). The procedure includes addition of deuterium-labelled standards, extraction with methanol-water-acetic acid (10:89:1, v/v), simple purification by Oasis® HLB cartridges, rapid chromatographic separation by UPLC, and sensitive, accurate quantification by MS/MS in multiple reaction monitoring modes. The detection limits of the technique ranged between 0.1 and 1 pmol for ABAGE and ABA acids in negative ion mode, and 0.01-0.50 pmol for ABAGE, ABAaldehyde, ABAalcohol and the methylated acids in positive ion mode. The fast liquid chromatographic separation and analysis of ABA and its eight measured derivatives by UPLC-ESI-MS/MS provide rapid, accurate and robust quantification of most of the substances, and the low detection limits allow small amounts of tissue (1-5 mg) to be used in quantitative analysis. To demonstrate the potential of the technique, we isolated ABA and its metabolites from control and water-stressed tobacco leaf tissues then analysed them by UPLC-ESI-MS/MS. Only ABA, PA, DPA, neoPA, and ABAGE were detected in the samples. PA was the most abundant analyte (ca. 1000 pmol/g f.w.) in both the control and water-stressed tissues, followed by ABAGE and DPA, which were both present at levels ca. 5-fold lower. ABA levels were at least 100-fold lower than PA concentrations, but they increased following the water stress treatment, while ABAGE, PA, and DPA levels decreased. Overall, the technique offers substantial improvements over previously described methods, enabling the detailed, direct study of diverse ABA metabolites in small amounts of plant tissue.  相似文献   

3.
A method has been developed and optimised for the determination of two natural estrogens, estrone (E1) and 17beta-estradiol (E2), and one synthetic estrogen, 17alpha-ethynylestradiol (EE2), in river sediments at the sub-ng/g level. This procedure includes microwave-assisted solvent extraction (MASE), solid-phase extraction and high-performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) with electrospray ionisation. Using sediments spiked with the three estrogens at 10 ng/g wet weight, efficient extraction (>92%) of all the three analytes was achieved by MASE, and whole-procedure recoveries ranged from 82 to 98%. Optimisation of the LC separation allowed for substantial reduction of ionisation suppression in the electrospray source to a final level of <18% suppression. Time-of-flight mass spectrometry (TOF-MS) and MS/MS were compared for the analysis of sediment extracts, with the latter technique proving to be the most selective. The method detection limits achieved by LC-MS/MS were 15, 30 and 40 pg/g for E1, E2 and EE2, respectively, which were 13-fold lower than those obtained by LC-TOF-MS. Analysis of river sediments collected from the River Ouse, UK, showed the presence of the natural estrogens at sub-ng/g level. E1 levels ranged from 0.40 ng/g (dry weight) to 3.30 ng/g while E2 levels ranged from <0.03 to 1.20 ng/g and EE2 was never detected (<0.04 ng/g).  相似文献   

4.
建立了采用超高效液相色谱-电喷雾电离串联质谱同时检测茶叶中爱比菌素、甲胺基阿维菌素、乙酰胺基阿维菌素、伊维菌素、多拉菌素、莫西丁克残留的方法。试样经饱和氯化钠溶液浸润后,用乙腈提取,C18固相萃取小柱净化,超高效液相色谱-电喷雾串联质谱法(UPLC/ESI-MS/MS)测定。对流动相、监测离子、校正曲线等进行了优化和探讨。6种分析物在2.0~50 μg/L范围内线性关系良好,相关系数均大于0.9920。莫西丁克在5,10,20 μg/kg,其余分析物在2,5,10 μg/kg加标水平的平均回收率为61.7%~85.4%,相对标准偏差为9.37%~17.19%。该方法可靠、稳定,可满足茶叶中阿维菌素类药物残留检测与确证的需要。  相似文献   

5.
A simple and robust method for quantification of zolpidem in human plasma has been established using liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI MS/MS). Es-citalopram was used as an internal standard. Zolpidem and internal standard in plasma sample were extracted using solid-phase extraction cartridges (Oasis HLB, 1 cm3/30 mg). The samples were injected into a C8 reversed-phase column and the mobile phase used was acetonitrile-ammonium acetate (pH 4.6; 10 mm) (80:20, v/v) at a flow rate of 0.7 mL/min. Using MS/MS in the selected reaction-monitoring (SRM) mode, zolpidem and Es-citalopram were detected without any interference from human plasma matrix. Zolpidem produced a protonated precursor ion ([M+H]+) at m/z 308.1 and a corresponding product ion at m/z 235.1. The internal standard produced a protonated precursor ion ([M+H]+) at m/z 325.1 and a corresponding product ion at m/z 262.1. Detection of zolpidem in human plasma by the LC-ESI MS/MS method was accurate and precise with a quantification limit of 2.5 ng/mL. The proposed method was validated in the linear range 2.5-300 ng/mL. Reproducibility, recovery and stability of the method were evaluated. The method has been successfully applied to bioequivalence studies of zolpidem.  相似文献   

6.
An analytical method is presented enabling the determination of nine neutral pharmaceuticals in groundwater, and for most of the compounds, in rivers and wastewater down to the lower ng/l range. The analytes belong to different medicinal groups such as antiphlogistics, psychiatric drugs and antidiabetics. Samples are enriched using solid-phase extraction (SPE) with RP-C18ec material. Analysis is performed by liquid chromatography with detection by electrospray tandem MS. Mean recoveries generally exceed 80% in groundwater, and the quantification limits are down to 50 ng/l in wastewater and down to 10 ng/l in groundwater. Losses were observed to occur either from ion suppression in the electrospray ionisation or SPE. Losses for all compounds could not be compensated for by the surrogate standard dihydrocarbamazepine. In raw municipal wastewater, concentration levels were detected for caffeine up to 147 microg/l and for propyphenazone up to 1.3 microg/l.  相似文献   

7.
建立了测定植物中痕量脱落酸 (ABA) 的液相色谱-电喷雾串联质谱联用分析方法. 植物提取液先采用固相萃取 (SPE) 富集脱落酸并消除基体干扰, 然后以C18柱为固定相, V(甲醇)∶V(2 g/L甲酸水溶液)=50∶50为流动相分离脱落酸. 电喷雾(ESI)串联质谱采用负离子模式. 选择反应监测 (SRM) 模式用于脱落酸定量, 选择的离子对是263→153, 219. 脱落酸的线性范围为0.005~10 μg/mL, 检测限 (S/N=3) 为0.003 μg/mL, 加标0.02 μg和0.05 μg的回收率分别为98.3% 和103.5%. 该方法用于冬青芽中脱落酸的分析, 结果表明所建立的SPE-LC-MS/MS方法对于分析植物中的痕量脱落酸是有效的.  相似文献   

8.
A multiresidue analysis method has been developed for the determination of pesticides in water by ultra-performance liquid chromatography (UPLC) combined with tandem mass spectrometry (MS/MS). The selected pesticides represent a broad range of polarity and volatility [benzoylcyclohexanedione (mesotrione and sulcotrione); chloroacetamide (acetochlor, alachlor, dimethenamide, and metolachlor); phenoxyacetic acid (2,4-D and MCPA); phenoxypropionic (dichloprop and mecoprop); phenylurea (chlortoluron, diuron, isoproturon, linuron, and metoxuron); sulfonylurea (foramsulfuron, iodosulfuron, and nicolsulfuron); triazine (atrazine, cyanazine, desethylatrazine (DEA), desisopropylatrazine (DIA), simazine, and terbutylazine)]. The analytes were extracted using solid-phase extraction (SPE). The separation was carried out on an acquity UPLC BEH C18 column (1.7 microm, 50 mm x 1 mm ID) using a gradient elution profile and mobile phase consisting of 0.1% formic acid in water and acetonitrile. The pesticides were detected with a tandem mass spectrometer after being ionised positively or negatively (depending on the molecule) using an electrospray ionisation (ESI) source. To achieve the suitable extraction conditions for sample preparation, several parameters affecting the efficiency of SPE such as the nature of the sorbent and the eluent, extractant volume and pH were studied. The best recovery was obtained by the extraction with an Oasis HLB cartridge and 3 mL of a solution of acetonitrile/dichloromethane (1:1, v/v) at pH 2. The average recoveries of the pesticides in different samples ranged from 82 to 109%. The weight least squares (WLS) linear regression was used to calculate the limits of detection and quantification (LOD and LOQ) because the dispersion was heteroskedastic. All the pesticides could be correctly quantified at a concentration level of 50 ng L(-1) and most of them could be detected at a concentration inferior or equal to 8 ng L(-1). Efficiency and robustness of this method were evaluated by the analysis of several samples of real natural water.  相似文献   

9.
Polyphenol compounds were extracted from Myrtus communis L. berries (Myrtaceae) by maceration in 70% ethanol and analysed by HPLC-DAD and electrospray mass spectrometry. The Myrtus berries were collected at maturity from seven localities on the island of Corsica (France) and the sampling was carried out during three years. The polyphenol composition of Corsican Myrtus berries was characterized by two phenolic acids, four flavanols, three flavonols and five flavonol glycosides. The major compounds were myricetin-3-O-arabinoside and myricetin-3-O-galactoside. Principal components analysis (PCA) is applied to study the chemical composition and variability of myrtle berries alcoholic extracts from the seven localities. Canonical analysis and PCA data distinguishes two groups of myrtle berries characterized by different concentrations of polyphenols according to soil and years of harvest. The variations in the polyphenol concentration were due to biotic and abiotic factors.  相似文献   

10.
Hexabromocyclododecanes (HBCDs), used as additive brominated flame retardants, are of high concern due to their widespread use and increasing levels in various environmental systems. High-performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry (LC-MS/MS) was developed for the determination of HBCD diastereoisomers. A detailed study was carried out to optimize the composition of the mobile phase involving methanol/acetonitrile/water, and the values of MS/MS parameters. It was found that the mobile phase could simultaneously affect the chromatographic separation and sensitivity. The instrumental limits of detection (LODs) on column in this study were 0.5, 0.3 and 0.3 pg for alpha-HBCD, beta-HBCD and gamma-HBCD, respectively. The effects of extracted matrix components on HBCD determination were investigated by spiking air and soil sample extracts with three 13C-labelled individual stereoisomers. The results indicated that the responses of the HBCD analysis in air and soils were not significantly affected by matrix effects. The method reported here was further applied to the air and soil samples. Three HBCD diastereoisomers were detected in all the air and soil samples, with levels ranging from 1.2 to 1.8 pg/m3 and 1.7 to 5.6 ng/g dry weight, respectively.  相似文献   

11.
A method based on liquid chromatography-tandem mass spectrometry (LC-MS/MS) for the direct quantification of glucuronides of testosterone (TG), epitestosterone (EPG), androsterone (AG) and etiocholanolone (ETG) has been developed. The method allowed for the direct determination of these analytes avoiding hydrolysis and derivatization, which are usual steps in commonly used methods based on gas chromatography-mass spectrometry (GC-MS). The electrospray ionization and the product ion spectra of the glucuronides have been studied in order to obtain the most specific transitions. The use of the selected transitions is necessary for the determination of the analytes at low ng/ml concentration levels. Two different approaches have been tested for sample preparation: direct injection after filtration and acidic liquid-liquid extraction (LLE) with ethyl acetate. Both approaches have been validated obtaining satisfactory values for accuracy and precision with limits of detection lower than 1 ng/ml for TG and EPG. Ion suppression was more pronounced after LLE probably due to the concentration of interferences from acidic urine. The applicability of the method has been checked by the analysis of 40 urine samples. The results were compared with those obtained with the common GC-MS method. Results have shown a good correlation between both methods with correlation coefficients higher than 0.97. A slope close to 1 was obtained for all analytes except for AG possibly due to losses during the extraction process prior to GC-MS.  相似文献   

12.
A system was developed for the separation of sulfophthalimide (SPI), sulfophthalamide (SPAM), sulfophthalamic acid (SPAA) and sulfophthalic acid (SPA) by ion-pair liquid chromatography and their detection by electrospray ionization tandem mass spectrometry (ESI-MS-MS). Except for SPAM, the 3- and 4-sulfo-isomers of the analytes were separated by HPLC using volatile tributylamine as ion-pairing agent. Initial fragmentations of the analytes in the negative mode involve losses of CO2 or HNCO or condensation via H2O or NH3 elimination. ortho-Effects of the sulfonate group were recognized in the fragmentation of the respective 3-sulfo-isomers and allowed us to assign the order of elution of the SPAA isomers. Quantitative analysis of these sulfonated aromatic compounds with MRM detection was elaborated and resulted in detection limits ranging from 1 pg for SPA to 13 pg for SPAA isomers and in limits of quantification of 2-10 microg/L for 5 microL volumes of injected tap water, municipal wastewater or industrial effluents up to salt contents of 0.5-1 g/L. The method was applied to study the isomer-specific chemical and microbial transformations of SPI, which was previously shown to be formed by white-rot fungi from sulfophthalocyanine textile dyes.  相似文献   

13.
Tsai TF  Lee MR 《Talanta》2008,75(3):658-665
Trace amounts of diuretics were determined in human urine by hollow fiber liquid-phase microextraction (LPME) combined with liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) in this study. Chromatography was performed on a C(8) reversed-phase column. A 25 microL n-octanol was used to extract analytes in urine. Extraction was optimized using a pH 2 solution spiked with 0.15 g/mL NaCl for 40 min at 40 degrees C with 1010 rpm stirring. The limits of detection of diuretics in urine were 0.3-6.8 ng/mL, and linearity range was 1-1000 ng/mL. Recoveries of spiked 50 ng/mL diuretics were 97.7-102.5%. The intra-day precision and inter-day precision were 3-18% and 4-21%, respectively. The diuretics concentration profiles in patient urine were also determined. The results of this study reveal the adequacy of LPME-LC-MS/MS method for analyzing diuretics in urine and quantification limits exceed World Anti-Doping Agency requirements.  相似文献   

14.
Molybdenum cofactor and isolated sulphite oxidase deficiencies are two related rare autosomal recessive diseases characterized by severe neurological abnormalities, dislocated lens and mental retardation. Determination of three biochemical markers S-sulphocysteine (SSC), xanthine (XAN) and hypoxanthine (HXAN) in urine is essential for a definitive diagnosis and identification of the exact defect. We developed a rapid liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the analysis of SSC, XAN and HXAN in urine. The analysis was carried out in the negative-ion selected-reaction monitoring mode. The turnaround time for the assay was 7 min. Linear calibration curves for the three biomarkers were obtained in the range of 12-480 micromol/L. The intra- and inter-day assay variations were <2.5%. Mean recoveries of SSC, XAN and HXAN added to urine at two significantly different concentrations were in the range 94.3-107.3%. At a normal SSC urine excretion value of 3.2 micromol/mmol creatinine, the signal-to-noise ratio was 337:1. This stable isotope dilution LC-MS/MS method is specific, rapid and simple, and provides definitive diagnosis for molybdenum cofactor and isolated sulphite oxidase deficiencies in very small volumes of urine. We have identified seven new cases of isolated sulphite oxidase deficiency from four Saudi families and one Sudanese family.  相似文献   

15.
A confirmatory method for the determination of trace levels of chlormequat in a variety of different food matrices was developed. It entails a single clean-up step over a solid-phase cation exchange resin and subsequent liquid chromatography-electrospray ionisation tandem mass spectrometry using a stable isotopically labelled internal standard. Mass spectral acquisition was done in selected reaction monitoring mode, selecting the transitions from both the 35Cl and the 37Cl isotope of chlormequat. Recoveries after extraction and clean-up, determined with radio-labelled chlormequat and averaged over the spiking range (16-65 microg kg(-1)) in four different commodities, were within 88-96%, with a coefficient of variation better than 8%. The method can be applied to pears, pear juice concentrates, fruit purées, and cereal products, with typical limits of detection for chlormequat estimated at 2-5 microg kg(-1). A survey of different food commodities revealed that chlormequat was detectable--albeit at very low levels--in many of the food samples analysed, with the highest concentration recorded in pears purchased in Switzerland and of South African origin (5.5 mg kg(-1)). Measurements were also conducted on two LC-MS instruments and demonstrate the versatility and robustness of the method and its applicability to instruments of different ion source design.  相似文献   

16.
A rapid and sensitive LC-ESI-MS-MS method has been developed for the determination of azadirachtin and abamectin residues in orange samples. Samples were extracted with acetonitrile, in a high-speed blender. After the addition of sodium acetate, an aliquot of extract was directly injected into the LC-ESI-MS-MS system. The highest sensitivity of the method was achieved under MS-MS conditions using [M+Na]+ adducts as precursor ions. Recoveries for both compoundsfrom spiked orange samples at 0.01 and 0.1 mg/kg were above 80%, with good repeatability (<10%). Method detection limits achieved (<0.007 mg/kg) were adequate for the determination of these pesticides in this kind of sample from the regulatory point of view. The importance of the solvent used for extraction, as well as the addition of sodium acetate to the extracts and the selection of adequate chromatographic conditions are discussed.  相似文献   

17.
建立了鸡组织中聚醚类药物多残留检测的高效液相色谱-电喷雾串联质谱方法。采用甲醇提取鸡组织中的拉沙洛菌素、盐霉素、莫能菌素、甲基盐霉素和马杜霉素,经硅胶柱净化,以乙腈(含0.1%甲酸)-0.1%甲酸水溶液(体积比为97:3)为流动相,Symmetry Shield RP18作为色谱分析柱,多反应监测(MRM)正离子扫描方式进行质谱检测。当5种聚醚类药物的添加水平为鸡肉0.1~1500 μg/kg、鸡肝0.2~4500 μg/kg时,平均回收率为71.6%~99.1%,日内测定的相对标准偏差(RSD)(n=5)为3.2%~10.7%,日间RSD(n=3)为4.6%~14.7%。2种鸡组织中5种聚醚类药物的定量限为0.1~1.0 μg/kg。该方法的灵敏度、准确度和精密度均符合兽药残留分析技术的要求,适用于鸡肉和鸡肝中5种聚醚类药物的多残留检测。  相似文献   

18.
LC/MS法分析头孢替坦二钠原料中的杂质   总被引:2,自引:0,他引:2  
本文应用LC/MS技术对头孢替坦二钠原料中的4种杂质进行了快速鉴定.根据头孢菌素的降解反应机制设计加速实验,确定头孢替坦的2个主要杂质为其碱水解产物;以1%冰醋酸溶液-乙腈-甲醇为流动相,经C18柱分离,通过电喷雾串联质谱负离子检测,获得各杂质的相对分子质量信息和碎片信息,并辅助UV特征对杂质结构进行了鉴定.在所建立的LC/MS条件下,头孢替坦及其杂质得到有效的分离,4个杂质经分析分别为5-巯基-1-甲基-四氮唑、头孢替坦内酯、头孢替坦脱羧物和头孢替坦异构体.本研究表明,利用LC/MS技术可推测头孢菌素类抗生素中杂质的结构,且本方法快速、灵敏、专属性高.  相似文献   

19.
Yang Z  Li X  Wang J  Zhang Q 《色谱》2011,29(9):927-931
建立了同位素稀释质谱测定猪肉中氯霉素残留的方法,对影响溶剂提取、萃取净化、液相色谱-质谱检测方法准确度的因素进行了量化与优化。猪肉样品经液氮冷冻粉碎,加入氯霉素-D5同位素内标和0.1 mol/L醋酸钠缓冲溶液(pH 5),用乙酸乙酯提取4次,正己烷脱脂,HLB固相萃取小柱净化后采用负离子多反应监测模式下的液相色谱-质谱技术检测。方法的线性范围为0.01~0.5 ng/g,相关系数r2大于0.999;检出限和定量限分别为0.004 ng/g和0.02 ng/g;在0.02 ng/g和1.0 ng/g加标水平的回收率(n=3)分别为95.2%~109.1%和99.7%~102.5%;日内和日间相对标准偏差均小于2%。研究了氯霉素及氯霉素-D5的基体效应,测得不同流动相和稀释溶剂组成时基体效应因子k的范围在0.950~1.015之间。研究结果对同位素稀释质谱痕量残留检测结果准确度的控制、方法的建立与验证具有参考意义。  相似文献   

20.
建立了禽类产品中克球酚残留的液相色谱-电喷雾串联质谱(LC-ESI-MS/MS)检测方法。用甲醇对样品进行提取,提取液用正己烷萃取去油脂,然后用LC-18柱和阴离子交换柱净化,LC-ESI-MS/MS测定。利用基质校正曲线对克球酚准确定量。在2,5,10,20 μg/kg 4个添加水平下,克球酚的平均回收率稳定在55.38%~132.44%之间,日内精密度小于9.54%,日间精密度小于15.27%。在1~40 μg/kg范围内色谱峰面积与克球酚含量呈良好的线性关系,检出限为0.5 μg/kg,定量限为2.0 μg/kg。该方法选择性好,抗干扰能力强,可作为禽类产品中克球酚残留检测的确证方法。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号