首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A selective, simple and fast dispersive micro solid phase extraction method using magnetic graphene oxide (GO) as an efficient sorbent has been developed for the extraction, separation and speciation analysis of chromium ions. The method is based on different adsorption behaviour of Cr(VI) and Cr(III) species onto magnetic GO in aqueous solutions which allowed the selective separation and extraction of Cr(VI) in the pH range of 2.0–3.0. The retained Cr(VI) ions by the sorbent were eluted using 0.5 mL of 0.5 mol L?1 nitric acid solution in methanol and determined by ?ame atomic absorption spectrometry. Total chromium content was determined after the oxidation of Cr(III) to Cr(VI) by potassium permanganate. All effective parameters on the performance of the extraction process were thoroughly investigated and optimised. Under the optimised conditions, the method exhibited a linear dynamic range of 0.5–50.0 µg L?1 with a detection limit of 0.1 µg L?1 and pre-concentration factor of 200. The relative standard deviations of 3.8% and 4.6% (n = 8) were obtained at 25.0 µg L?1 level of Cr(VI) for intra- and inter-day analysis, respectively. The method was successfully applied to the speciation and determination of Cr(VI) and Cr(III) in environmental water samples.  相似文献   

2.
A micro-cloud point extraction method was discussed for preconcentration and spectrophotometric quantification of U(VI). The method depends on complex formation between U(VI) and 2-(4-sulphophenyloazo)-1,8-dihydroxy-3,6-naphtalenedisulphonic acid (SPADNS) at pH 7.0 and subsequent extraction of the complex in a mixed surfactant medium (cethyltrimethyl ammonium bromide and Triton X-114). The separation was carried out in the presence of 1% Na2SO4 at room temperature. The calibration curve was linear up to 3000 µg L?1. The enrichment factor, detection limit and precision were 16.0, 1.05 µg L?1, and 2.3%, respectively. The method was employed for the determination of U(VI) in real samples with different matrices.  相似文献   

3.
《Analytical letters》2012,45(3):504-516
A novel method for separation and determination of rhodamine B in food samples is described. The work is based on the utilization of an ionic liquid loaded β-cyclodextrin cross-linked polymer coupled with high-performance liquid chromatography for the determination of rhodamine B. The inclusion interaction of the ionic liquid-β-cyclodextrin cross-linked polymer with rhodamine B was studied by FTIR. Under optimum conditions, the preconcentration factor achieved for this method was approximately 20. The linear range, detection limit, and relative standard deviation were 0.80 to 130.0 µg L?1, 0.09 µg L?1, and 0.66% (n = 3, concentration = 10.0 µg L?1), respectively. The technique was successfully applied for determination of rhodamine B in food samples.  相似文献   

4.
A novel method for preconcentration is described for chromium speciation at microgram per liter to sub-microgram per liter levels. It is based on selective complex formation of both Cr(VI) and Cr(III) followed by dispersive liquid–liquid microextraction and determination by microsample introduction-flame atomic absorption spectrometry. Effects influencing complex formation and extraction (such as pH, temperature, time, solvent, salinity and the amount of chelating agent) have been optimized. Enrichment factors up to 275 and 262 were obtained for Cr(VI) and total Cr, respectively. The calibration graph is linear from 0.3 to 20 µg L?1, and detection limits are 0.07 and 0.08 µg L?1 for Cr(VI) and total Cr, respectively. Relative standard deviations (RSDs) were obtained to be 2.0% for Cr(VI) and 2.6% for total Cr (n?=?7).  相似文献   

5.
《Analytical letters》2012,45(14):2214-2231
Abstract

A new simple and sensitive method has been proposed for rapid determination of trace levels of silver in environmental water samples, using dispersive liquid–liquid microextraction (DLLME) prior to its microsample introduction-flame atomic absorption spectrometry. Under the optimum conditions, the linear range was 0.1–7 µg L?1 and limit of detection was 0.018 µg L?1. The relative standard deviation for 0.50 and 5.00 µg L?1 of silver in water sample was 4.0 and 1.7%, respectively. The relative recoveries of silver from tap, well, river, and seawater samples at spiking levels of 1.00 and 5.00 µg L?1 were in the range of 86.4–98.6%.  相似文献   

6.
A new and sensitive precolumn derivatisation with dabsyl chloride was developed for the analysis of melamine in water samples by high-performance liquid chromatography (HPLC) with visible detection. Derivatisation with dabsyl chloride leads to improving sensitivity and hydrophobicity of melamine. Under optimum conditions of derivatisation and microextraction, the method yielded a linear calibration curve ranging from 10 to 2000 µg L?1 with a determination coefficient (R2) of 0.9952. Limit of detection (LOD) and limit of quantification (LOQ) were 2.0 and 6.0 µg L?1, respectively. The relative standard deviation per cent (RSD%) for intraday and inter-day extraction and determination at 20 and 200 µg L?1 levels of melamine was less than 8.2% (n = 6). Finally, the proposed method was successfully applied for the determination of melamine in different water samples and satisfactory results were obtained (relative recovery ≥91%).  相似文献   

7.
In the present study, ionic liquid-modified silica-coated magnetic nanoparticles (MNPs) were synthesised and applied as a new anion-exchange sorbent for extraction and determination of Cr(VI) followed by inductively coupled plasma atomic emission spectrometry. The characterisation of MNPs was carried out by scanning electron microscope, Fourier transform infrared and vibrating sample magnetometer. Experimental design and response surface methodology were used for optimisation of different parameters which affect extraction efficiency of Cr(VI). Under the optimised conditions, extraction recoveries within the range of 25–33% with relative standard deviations (RSD%, n = 4) within the range of 3.0–5.0% were obtained. The limit of detection was found to be 0.1 µg L?1. The linearity was studied in the range of 0.5-200 µg L?1 with the determination coefficient of 0.9958. Also, calculated Errors% for determination of Cr(VI) in the range of 5-15 depict that the method offers acceptable accuracy for analysis of Cr(VI). The method was successfully applied for extraction and determination of Cr(VI) selectively in some tannery waste water samples.  相似文献   

8.
《Analytical letters》2012,45(13):2195-2208
A sensitive and simple method for the determination of trace nickel was developed by the combination of dispersive liquid–liquid microextraction (DLLME) and microsample injection system–flame atomic absorption spectrometry (MIS–FAAS). Trace nickel was preconcentrated as the 8-hydroxyquinoline chelate by DLLME, and the conditions were optimized by a Plackett-Burman design. Quantitative recovery of nickel (98 ± 1%) was obtained by a sample volume of 7.5 mL at a pH of 6.0. The enrichment factor was 52.5, and the limits of detection and quantitation were 0.1 µ g L?1 and 3.0 µ g L?1, respectively. The method was validated by the analysis of a wastewater standard reference material, water samples, and a wire sample. The reported method has superior analytical figures of merit compared with similar methods reported in the literature.  相似文献   

9.
The possibility of using ionic liquid based chitosan sorbent for the separation and preconcentration of fluoroquinolone antibiotics (marbofloxacin, enoxacin, ofloxacin, ciprofloxacin, and enrofloxacin) has been studied. For this reason, different ionic liquids were prepared and coated on the chitosan sorbent. The conditions of the preconcentration of fluoroquinolones on a microcolumn have been optimized and the extraction efficiencies of the prepared sorbents have been compared. The compounds were eluted with 5 mL of 20% NH3 (v/v, MeOH) solution and determined by HPLC with diode array and fluorescence detector. The limits of detection were found as 4.23 µ g L?1 for marbofloxacin, and 1.09 µg L?1 for enoxacin; 3.23 × 10?3 µg L?1 for ofloxacin; 8.39 × 10?3 µg L?1 for ciprofloxacin; and 19.50 × 10?3 µg L?1 for enrofloxacin. The developed method was applied for the analysis of fluoroquinolone in milk, egg, fish, bovine, and chicken samples and the recoveries were obtained in the range 70–100%.  相似文献   

10.
《Analytical letters》2012,45(17):2747-2757
Abstract

Brazilian sugarcane spirits were analyzed to elucidate similarities and dissimilarities by principal component analysis. Nine aldehydes, six alcohols, and six metal cations were identified and quantified. Isobutanol (LD 202.9 µg L?1), butiraldehyde (0.08–0.5 µg L?1), ethanol (39–47% v/v), and copper (371–6068 µg L?1) showed marked similarities, but the concentration levels of n-butanol (1.6–7.3 µg L?1), sec-butanol (LD 89 µg L?1), formaldehyde (0.1–0.74 µg L?1), valeraldehyde (0.04–0.31 µg L?1), iron (8.6–139.1 µg L?1), and magnesium (LD 1149 µg L?1) exhibited differences from samples.  相似文献   

11.
A simple, sensitive and reliable method has been developed for separation and preconcentration of chromium (VI) from aqueous samples before determination by electrothermal atomic absorption spectrometry. The method is based on the extraction of the hydrophobic complex of chromium (VI) with ammonium pyrrolidine dithiocarbamate in the coacervates made up of decanoic acid reverse micelles in the water–tetrahydrofuran mixture. Parameters affecting the extraction efficiency of the analyte were studied and optimised. Under the optimum conditions, the linear range, enhancement factor, the limit of detection and limit of quantification were found to be 0.008–0.4 µg L?1, 127, and 1.8 ng L?1 and 6.0 ng L?1, of Cr(VI), respectively. The relative standard deviation at the concentration level of 0.1 µg L?1 Cr(VI) (n = 6) was 4.2%. Total chromium was determined after the oxidation of Cr(III) to Cr(VI) with permanganate in acidic medium. The method was successfully applied to the determination of chromium species in water and human serum samples.  相似文献   

12.
In the present work, synthesis of polymer wrapped flower-like MgAl layered double hydroxide was done through condensation of 1,4 phenylenediamine and resorcinol by p-formaldehyde. The nanocomposite was characterised with X-ray diffraction analysis, fourier transform infrared spectroscopy, thermogravimetric analysis and field emission scanning electron microscopy techniques and employed for effective adsorption of Cr(VI) from aqueous solution prior to flame atomic absorption spectrometer determination. Optimum level of effective parameters (pH, reaction time and adsorbent dosage) and their interaction was determined by response surface methodology. To investigate applicability of method for trace heavy metal adsorption, the method was employed for preconcentration of Cr(VI) in water samples. At the optimum conditions, pH = 4.5, shaking time of 15 min and adsorbent dosage of 20 mg, analytical performance of the method was evaluated and results showed that calibration curve is linear in the concentration range of 2–100 μg L?1. Moreover, limit of detection was 0.22 µg L?1 and relative standard deviation of six replicate experiments at initial concentration of 0.1 mg L?1 was 3.3%. Isotherm study showed that Freundlich model can better describe adsorption behaviour as well as the sorbent showed the adsorption capacity of 62.5 mg g?1. Moreover, thermodynamic study revealed that chromate adsorption was spontaneous and followed the endothermic path. Regeneration of sorbent was performed using 1.0 mol L?1 of NaOH solution. The sorbent was employed for Cr(VI) determination from food additives and seawater samples.  相似文献   

13.
《Analytical letters》2012,45(13):2075-2088
For the first time, a simple method for magnetic stirring-assisted dispersive suspended microextraction has been developed for the determination of three fungicides (azoxystrobin, diethofencarb, and pyrimethanil) in water and wine samples. The method is based on the solidification of a floating organic droplet coupled with high performance liquid chromatography. In the proposed method, the low toxicity solvent 1-dodecanol was used as the extractant. Both the extraction and phase separation process were performed with magnetic stirring. No centrifugation step was involved. After separating the two phases, the extraction solvent droplet was easily collected through solidification at lower temperature. Important parameters such as the kind and volume of organic extraction solvent, extraction and restoration speed, extraction and restoration time, and salt concentration were optimized. Under the optimal conditions, the limits of detection for the analytes varied from 0.14 to 0.26 µg L?1. The enrichment factors ranged from 125–200. The linearity ranges were 1–2000 µg L?1, yielding correlation coefficients (r) higher than 0.9990. The relative standard deviation (n = 6) at two spiked level of 0.2 µg mL?1 and 4 µg L?1 varied between 2.2% and 7.8%. Finally, the developed technique was successfully applied to determine target fungicides in real water and wine samples, where the obtained recoveries ranged from 83.8–105.3%  相似文献   

14.
《Analytical letters》2012,45(14):1995-2005
Using 1-hexyl-3-methylimidazolium hexafluorophosphate ([C6MIM][PF6]) ionic liquid as extraction solvent, five estrogens including estrone (E1), 17β-estradiol (E2), estriol (E3), 17α -ethynylestradiol (EE2), and diethylstilbestrol (DES) in water samples were determined by dispersive liquid-liquid microextraction (DLLME) followed by high performance liquid chromatography with a photodiode array detector and a fluorescence detector (HPLC-DAD-FLD). The extraction procedure was induced by the formation of cloudy solution, which was composed of fine drops of [C6MIM][PF6] dispersed entirely into the sample solution with the help of a disperser solvent (acetone). Parameters including both extraction and disperser solvents and their volumes, extraction and centrifugal time, sample pH, and salt effect were investigated and optimized. Under the optimized conditions, 110–349 fold enrichment factors of analytes were obtained. The calibration curves were linear in the concentration range of 0.2–100 µg L?1 for E2, E3, and EE2 detected with FLD, and 1–100 µg L?1 for E1 and DES detected with DAD. The correlation coefficient of the calibration curve was between 0.9990 and 0.9997. The limits of detection (LOD, S/N = 3) for the five estrogens were in the range of 0.08–0.5 µg L?1. The relative standard deviations (RSD) for six replication experiments at the concentration of 5.0 µg L?1 were ≤5.7%. The proposed method was applied to the analysis of three water samples from different sources (river water, waste water, and sea water). The relative recoveries of spiked water samples are satisfied with 89.3–102.4% and 88.7–105.2% at two different concentration levels of 5.0 and 50.0 µg L?1, respectively.  相似文献   

15.
《Analytical letters》2012,45(15):2508-2521
Porous polyaniline coatings doped with different counter ions were electrodeposited on the surface of stainless steel wires using controlled potentiostatic coulometry. Prior to electropolymerization, the stainless steel wires were chemically etched to improve subsequent immobilization of the polyaniline coatings on the substrate and to increase the effective surface area. Porous polyaniline coatings doped with sulfate, nitrate, and perchlorate counter ions were employed for solid-phase microextraction (SPME) of 2-chlorophenol, 2,4-dichlorophenol, triclosan, and 2,4-dichlorophenoxyacetic acid coupled to high-performance liquid chromatography. The results demonstrated that the perchlorate doped polyaniline coating exhibited the highest extraction efficiency for 2-chlorophenol, 2,4-dichlorophenol, and triclosan at pH 5.0, indicating that the extraction capability was modified by introducing different counter ions into the coatings. As a result, the perchlorate doped polyaniline coated fiber was further used for the optimization of extraction condition s . The method provided linear dynamic ranges over 2 to 4 orders of magnitude. The limits of detection were 0.006 µg · L?1, 0.005 µg · L?1, and 0.040 µg · L?1 for 2-chlorophenol, 2,4-dichlorophenol, and triclosan, respectively. The precision expressed as the relative standard deviation ranged from 2.20% to 5.04% for spiked water at 10 µg · L ?1 (n = 5) and the fiber to fiber reproducibility was between 3.27% and 5.91% (n = 5). The method was successfully applied to the determination of chlorophenolics in real water samples. The recoveries of chlorophenolics in spiked water at 5.0 µg · L?1 were between 99.60% and 108.7% with relative standard deviations between 3.24% and 5.47%.  相似文献   

16.
This paper established a new, rapid and sensitive method for the ultra-trace determination of lead, cadmium and nickel in food and environmental samples preconcentrated by dispersive solid-phase extraction (DSPE) combined with surfactant-assisted dispersive liquid–liquid microextraction (SA-DLLME) prior to graphite furnace atomic absorption spectrometry. SBA-15/Met was synthesized and used as a new efficient sorbent for the extraction of metal ions in DSPE. It was characterized by TEM and TGA techniques. After DSPE step, stripped metal elements were complexed with dithizone, and then, the complexes were extracted into carbon tetrachloride by using SA-DLLME. A conventional nonionic surfactant, triton X-100 was used as a disperser agent. Under the optimized conditions, the limit of quantifications was found to be 2.5 ng L?1 for Pb2+, Cd2+ and 5.0 ng L?1 for Ni2+. The limits of detection were 1.5 ng L?1 for Ni2+ and 0.75 ng L?1 for Pb2+ and Cd2+, with enrichment factor of 1650. The optimized method exhibited a good precision level with relative standard deviations (RSDs%) values of 4.9, 5.2 and 5.0% for 1 μg L?1 Pb2+, Cd2+ and Ni2+, respectively (n = 7). Application of the proposed method to the analysis of fish-certified reference material produced results that were in good agreement with the certified values.  相似文献   

17.
This study presents an easy and cost-effective flow-based cloud point extraction (CPE) method for determining partial amounts of two organophosphorus pesticides (phosalone and ethion) in seawater by HPLC–UV–Vis. In continues CPE methodology, the effect of the different column packing type such as carbon nanotube, polyacrylonitrile nanofiber and fiberglass on pesticide extraction was investigated. The Triton X-100 was utilized as nonionic surfactant, and moreover, effect of different parameters such as pH, temperature, extraction time, surfactant concentration, type and volume of the eluent solution on the extraction efficiency was optimized. Under optimum conditions, the figures of merit of the method for phosalone and ethion were obtained as: the enrichment factor (172 and 166), line range (0.8–300 and 0.5–300 µg L?1, R 2 = 0.9973 and 0.9982), relative standard deviation in concentration of 200 µg L?1 (%RSD = %5.4 and %7.99, N = 5) and limit of detection (LOD = 0.24 and 0.14 µg L?1). The suggested method was successfully used for determination of phosalone and ethion in Chabahar Bay seawaters with satisfactory results.  相似文献   

18.
《Analytical letters》2012,45(14):2184-2192
A new procedure for trace tungsten W(VI) in soil by fluorescence quenching method coupled with cloud point extraction (CPE) as the separation-preconcentration method was described. The Triton X-100 CPE behavior of W(VI)-salicylfluorone (SAF)was investigated. Under the optimized conditions, the fluorescence quenched intensity (ΔF) was linearly with W(VI). The range of linear was 0.8 ~ 20.0 μg · L?1, the detection limit (DL) was 0.14 ng · mL?1 (3σ), the relative standard deviation 3.3% (c = 10.0 μg · L?1, n = 5) and the recovery was 101.0–102.2%. The proposed method applied to the analysis of W(VI) in certified reference materials and real samples.  相似文献   

19.
《Analytical letters》2012,45(10):1759-1771
A robust gold-coated solid-phase microextraction fiber was rapidly prepared on an etched stainless-steel wire based on chemical deposition. Gold(III) was reduced to produce a mechanically robust fiber with a stable coating. Subsequently, it was applied for solid-phase microextraction of five polycyclic aromatic hydrocarbons in water samples coupled to high performance liquid chromatography with an ultraviolet-visible detector. The preconcentration conditions were optimized, including extraction and desorption time, temperature, stirring rate, and ionic strength. Under the optimized conditions, the calibration graphs were linear in the range from 1 to 500 µg · L?1 for naphthalene and 0.20–500 µg · L?1 for phenanthrene, anthracene, fluoranthene, and pyrene. Limits of detection were between 0.016 and 0.22 µg · L?1 (signal-to-noise ratio = 3). The analysis of water samples showed that the recoveries ranged from 86.0% to 112.9% with relative standard deviations between 2.03% and 11.7%. The fiber coating was sensitive and suitable for the preconcentration and determination of polycyclic aromatic hydrocarbons in environmental waters. Compared with previously reported solid-phase microextraction methods, this device offered easy preparation, low cost, resistance to organic solvents, good stability, and high durability.  相似文献   

20.
《Analytical letters》2012,45(2):343-355
A new analytical procedure for the determination of five organotin compounds in several matrix wine samples is reported. The organotin compounds were extracted by microwave-assisted extraction with n-hexane. Extraction conditions, such as volume of n-hexane required, extraction temperature, and extraction time, were investigated and optimized by an orthogonal array experimental design. The determination of organotin compounds in the final extracts was carried out by liquid chromatography–inductively coupled plasma mass spectrometry. The procedure showed limits of detection between 0.029–0.049 µg · L?1. The linearity was in the range of 0.5 to 100 µg · L?1. The precision expressed as relative standard deviation (RSD) was below 9.43%. The developed method was successfully employed to analyze different matrix wine samples, and some analytes were detected at the level of 0.053 to 1.14 µg · L?1.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号