首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
In this work, a new 2-(2-oxoethyl)hydrazine carbothioamide modified silica gel (SG-OHC) sorbent was prepared and applied for preconcentration of trace mercury(II) prior to the measurement by inductively coupled plasma atomic emission spectrometry (ICP-AES). The optimization of some analytical parameters affecting the adsorption of the analyte such as acidity, shaking time, sample flow rate and volume, eluent condition, and interfering substances were investigated. At pH 3, the maximum static adsorption capacity of Hg(II) onto the SG-OHC was 37.5 mg g−1. The quantitative recovery (>95%) of Hg(II) could be obtained using 2 mL of 0.5 mol L−1 HCl and 1% CS(NH2)2 solution as eluent. Common coexisting substances did not interfere with the separation of mercury(II) under optimal conditions. The detection limit of present method was 0.10 ng mL−1, and the relative standard deviation (RSD) was lower than 4.0% (n = 8). The prepared sorbent was successfully applied for the preconcentration of trace Hg(II) in certified and water samples with satisfactory results.  相似文献   

2.
 A new chromogenic reagent, 2-(2-quinolylazo)-5-diethylaminoaniline(QADEAA), was synthesized. A highly sensitive, selective and rapid method for the determination of silver was developed. It is based on the rapid reaction of silver (I) with QADEAA and the solid phase extraction of colored chelate using reversed-phase separation cartridge. At pH 6.5 in the presence of sodium dodecyl sulfonate (SDS), QADEAA reacts with silver to form a violet chelate in a molar ratio of 1:2 (silver to QADEAA). This chelate was enriched by solid phase extraction. The retained chelate can be eluted from the cartridge with ethanol. In ethanol medium, the molar absorptivity of the chelate is 1.36×105 L·mol−1·cm−1 at 590 nm. Beer’s law is obeyed in the range 0.01–0.6 μg L−1. The relative standard deviation for eleven replicate samples of 0.01 μg L−1 level is 1.9%. The detection limit reaches the 0.02 μg L−1 level. This method shows satisfactory results when used for the determination of silver in water. Correspondence: Department of Chemistry, Yuxi Teacher’s College, Yuxi, 653100, P.R. China. e-mail: hugiufena@163.com Received 19 August 2002; accepted 20 October 2002  相似文献   

3.
Multiwalled carbon nanotubes chemically functionalized with 2-((3-silylpropylimino) methyl) phenol (SPIMP-MWCNT) and successfully applied for the solid phase extraction (SPE) of some metal ions in food samples. The influences of the analytical parameters including pH, amounts of solid phase, eluent conditions (type, volume and concentrations), sample volume and interference of some metal ions on the recoveries of ions Cu2+, Pb2+, Fe2+, Ni2+ and Zn2+ ion were investigated. The metal ions retained on SPIMP-MWCNT was eluted using 6?mL of 4?mol?L?1 HNO3 solution and their content was determined by flame atomic absorption spectrometry (FAAS) with recoveries more than 95% and relative standard deviations (n?=?5) between 2.4–3.4% for both reproducibility and repeatability. The detection limit of this metal ions was between 1.0–2.6?ng?mL?1 (3S b , n?=?10) and their preconcentration factor was 100, while their loading capacity was above 32.9?mg?g?1 of SPIMP-MWCNT. The proposed method was successfully applied for the preconcentration and determination of analytes in different samples.  相似文献   

4.
A solid phase extraction procedure has been developed using multiwalled carbon nanotubes (MWCNTs) as a solid sorbent and quinalizarin [1,2,5,8-tetrahydroxyanthracene-9,10-dione] as a chelating agent for separation and preconcentration of trace amounts of some heavy metal ions, Cd(II), Cu(II), Ni(II), Pb(II) and Zn(II) before their determination by flame atomic absorption spectroscopy (FAAS). The influences of the analytical parameters, including pH, amounts of quinalizarin and adsorbent, sample volume, elution conditions such as volume and concentration of eluent, flow rates of solution and matrix ions, were investigated for the optimum recoveries of the analyte ions. No interference effects were observed from the foreign metal ions. The preconcentration factor was 100. The detection limit (LOD) for the investigated metals at the optimal conditions were observed in the range of 0.30–0.65 μg L?1. The relative standard deviation (RSDs), and the recoveries of standard addition for this method were lower than 5.0% and 96–102%, respectively. The new procedure was successfully applied to the determination of analytes in food, water and environmental samples with satisfactory results.  相似文献   

5.
研究了新试剂2[2(4甲基喹啉)偶氮]5二乙氨基苯酚(QADP)与镉的显色反应。在pH为8.0的硼酸氢氧化钠缓冲介质中,TritonX100存在下,QADP与镉反应生成2∶1稳定络合物。体系最大吸收波长λmax=590nm,摩尔吸光系数ε=1.56×105L·mol-1·cm-1。样品中的镉用强阴离子交换固相萃取柱固相萃取预分离和富集后用该方法测定,结果令人满意。  相似文献   

6.
3-(2-Quinolyl)- and 3-(5-carbethoxyfuryl-2)coumarins were prepared by reaction of substituted salicylaldehydes and hetarylacetonitriles. Alkylation and acylation of 3-hetaryl-7-hydroxycoumarins were studied. __________ Translated from Khimiya Prirodnykh Soedinenii, No. 5, pp. 432–434, September–October, 2005.  相似文献   

7.
Zhifeng Tu  Lijun Zhang  Qun He  Jianping Shi  Ru Gao 《Talanta》2010,80(3):1205-1747
A new method that utilizes 1-(2-aminoethyl)-3-phenylurea-modified silica gel as a solid-phase extractant has been developed for preconcentration of trace Sc(III) prior to the measurement by inductively coupled plasma atomic emission spectrometry (ICP-AES). Experimental conditions for effective adsorption of trace level of Sc(III) were optimized using batch and column procedures in detail. The optimum pH value for the separation of Sc(III) on the new sorbent was 4 and complete elution of Sc(III) from the sorbent surface was carried out using 1.0 mL of 0.1 mol L−1 HCl. Common coexisting ions did not interfere with the separation and determination of the analyte. The maximum static adsorption capacity of the sorbent at optimum conditions was found to be 32.5 mg g−1 while the time of 95% adsorption was less than 2 min. The detection limit of present method was found to be 0.091 μg g−1, and the relative standard deviation (RSD) was lower than 3.0% (n = 8). The method was successfully applied for the preconcentration of trace Sc(III) in the environmental samples with satisfactory results.  相似文献   

8.
ABSTRACT

In this study, preconcentration and separation of Cu(II) and Pb(II) ions by using Fe3O4@SiO2@Bacillus pumilis before their determinations by flame atomic absorption spectrometry (FAAS) were investigated. The thermophilic Bacillus pumilis were isolated from Meyremderesi spring, ??rnak, Turkey. Effects of important parameters such as pH, adsorbent amount, eluent type, concentration and volume of eluent and sample volume on magnetic solid phase extraction (MSPE) were examined in details. The preconcentration factors for Cu(II) and Pb(II) ions were calculated as 30 and 40, respectively. The accuracy of the proposed extraction procedure was validated analysing certificated reference materials and addition – recovery tests. The concentration of copper and lead were determined in water samples from Turkey by Flame AAS after application developed preconcentration-separation method.  相似文献   

9.
用2-(2-喹啉偶氮)-5-二乙氨基苯甲酸(QADEAB)与镍的显色反应及Waters Porapak^R Sep-Park固术萃取小柱对显色络合物的固相萃取,建立了测定水样中μg/L级镍的新方法。水样中的镍在pH=8.0的硼酸-磷酸二氢钾缓冲介质中和Tween 80存在下与QADEAB反应生成2:1稳定有色络合物,该络合物可用Waters Porapak^R Sep-Park固相萃取小柱富集,用乙醇洗脱后用光度法测定,可测定水样中μg/L级的镍。方法用于几种环境水样分析,结果令人满意。  相似文献   

10.
The Amberlite XAD-7 resin modification was carried out by loading 2-(1-(4-chlorophenyl)-4,5-diphenyl-1H-imidazol-2yl)-4-nitrophenol (CPDPINP). Subsequently, this new sorbent was applied for the enrichment of metal ions such as Cu2+, Ni2+, Co2+ Zn2+ and Pb2+ ions. The effect of various parameters on their sorption and following recoveries was studied in column procedure. The preconcentrated ions were eluted by appropriate eluent and their contents were quantified by FAAS. This method has preconcentration factor of 150 and enrichment factor in the range of 20.8–29.1. At optimum values of all variables, the proposed method has linear calibration graphs in the range of 0.01 up to 0.29 μg mL−1 with detection limit (3SDb/m, n = 15) between 1.6 and 2.6 ng mL−1. This protocol is usable for successful analysis of Cu2+, Ni2+, Co2+ Zn2+ and Pb2+ ions in different matrices with reasonable recoveries (>93%) and acceptable relative standard deviation (<4.7%).  相似文献   

11.
In the present work, a simple procedure is presented for the extraction and determination of pre-concentrated trace amounts of palladium ions through solid phase extraction (SPE) and flame atomic absorption spectrophotometry. This process was performed using Nylon-66/5-(4-dimethylaminobenzylidene) rhodanine composite nanofibres. These nanofibres were produced under optimised conditions via two-axial electrospinning technique and characterised by scanning electron microscopy and Fourier-transform infrared spectroscopy. The effect of experimental parameters including solution pH, the type and volume of eluent and contact time was investigated in extraction and desorption process. Under the optimised conditions, good linearity in the range of 0.07–8 μg L?1 and low detection limit of 0.015 μg L?1 were obtained. High enrichment factor of 187.5 and good relative standard deviation of ±2.2% at 5 μg L?1 of palladium had been achieved. The sorbent capacity for palladium adsorption was obtained 27 mg palladium per gram of nanofibres. So, the SPE was successfully applied to pre-concentrate and determine Pd(II) ions with flame atomic absorption spectrophotometer in real samples.  相似文献   

12.
3-Chloro-2-polyfluoroalkyl- and 3-chloro-6-nitro-2-polyfluoroalkylchromones were synthesized. These compounds react with N2H4·2HCl on boiling in ethanol to form 4-chloro-3(5)-(2-hydroxyaryl)-5(3)-polyfluoroalkylpyrazoles.  相似文献   

13.
在低加热条件下(<100℃), 研究了Cu(OAc)2.H2O与1-苯基-3-甲基-4-苯甲酰基吡唑啉酮-5-(HPMBP)两种异构体(烯醇式与酮式)的固相配位化学反应, 结果表明两种异构体与Cu(OAc)2.H2O固相化学反应活性并不相同。通过IR, UV测定, 发现酮式异构体在与Cu(OAc)2.H2O的固相反应过程中, 其自身经过了一个由酮式到烯醇式的固相异构化。  相似文献   

14.
GHAEDI  Mehrorang  TAVALLALI  Hossein  KESHAVARZ  M.  NIKNAM  K. 《中国化学》2009,27(10):2066-2072
A sensitive and simple method for the simultaneous preconcentration of trace amount Cu2+ and Zn2+ ions in some real samples has been established, which is based on the sorption of Cu2+ and Zn2+ on 3‐((1H‐indol‐3‐yl)‐3,4,5‐trimethyl)‐1H‐indole (ITMI) loaded on sodium dodecyl sulfate (SDS) coated alumina. The metal absorbed on the complexes was eluted using 3 mol/L nitric acid. The influences of the analytical parameters including pH and sample volume were investigated. The effects of matrix ions on the retentions of the analytes were also examined. The recoveries of analytes were generally higher than 95% with a low RSD. The method has been successfully applied to content evaluation of these metals in real samples.  相似文献   

15.
The efficiencies and performances of silver nanoparticle loaded activated carbon modified with 2-(4-isopropylbenzylideneamino)thiophenol (IPBATP-Ag-NP-AC) and activated carbon modified with IPBATP (IPBATP-AC), as new sorbents, were evaluated for separation and preconcentration of Cu2+, Zn2+, Co2+, Cd2+ and Pb2+ ions from real environmental samples. The retained metals content was reversibly eluted using 5?mL of CH3COOH (6.0?mol?L?1) and/or 10?mL of 4.0?mol?L?1 HNO3 for IPBATP-Ag-NP-AC and IPBATP-AC, respectively. The experimental parameters influence the recoveries of metal ions including pH, amounts of ligand and supports, condition of eluents, sample and eluent flow rates of has been investigated. The preconcentration factors were found to be 100 for Zn2+, Cd2+, Co2+, Cu2+ and 50 for Pb2+ ions using IPBATP-Ag-NP-AC, and 50 for Zn2+, Cd2+, Co2+, Cu2+ and 25 for Pb2+ ions using IPBATP-AC. The detection limit of both SPE-based sorbents was between 1.6–2.5?ng?mL?1 for IPBATP-AC and 1.3–2.5?ng?mL?1 for IPBATP-Ag-NP-AC. The proposed methods have been successfully applied for the extraction and determination of the understudy metal ions content in some real samples with extraction efficiencies higher than 90% and relative standard deviations (RSD) lower than 2.4%.  相似文献   

16.
A solid phase extraction system for separation and preconcentration of trace amounts of Pb(II), Ni(II), Cd(II) and Cu(II) is proposed. The procedure is based on the adsorption of Pb2+, Ni2+, Cd2+ and Cu2+ ions on a column of 1-(2-pyridylazo)-2-naphthol (PAN) immobilised on surfactant-coated clinoptilolite prior to their determinations by Flame Atomic Absorption Spectroscopy (FAAS). The effective parameters including pH, sample volume, sample flow rate and eluent flow rate were also studied. The analytes collected on the column were eluted with 5 mL of 1 mol L?1 nitric acid. A concentration factor of 180 can be achieved by passing 900 mL of sample through the column. The detection limits (3 s) for Cd, Cu, Pb and Ni were found to be 0.28, 0.12, 0.44 and 0.46 µg L?1, respectively. The relative SDs at 10 µg L?1 (n = 10) for analytes were in the range of 1.2–1.4%. The method was applied to the determination of Pb, Ni, Cd and Cu in water samples.  相似文献   

17.
A simple, selective and reliable method for rapid extraction and determination of trace amounts of Cu (II) ions from aqueous samples using octadecyl-bonded silica membrane disks modified with bis-(3-methoxy salicylaldehyde)-1,6-diaminohexane and flame atomic absorption spectrometry (FAAS) is presented. Extraction efficiency, the influence of pH, flow rates, amount of ligand, and type and least amount of eluant were investigated. The linear dynamic range of the proposed method for Cu (II) ions was found in a wide concentration range of 1.0 (± 0.2)–150 (± 2) μg l− 1. The detection limit and preconcentration factor of this method were found 30.0 (± 0.7) ng l− 1 and 100 respectively. The reproducibility of the procedure is at the most 2.0%. The effects of various cationic interferences on the percent recovery of copper ion were studied. The method was used to the recovery of copper ion from different synthetic, alloys and biological samples.  相似文献   

18.
本文研究了铀-2-(3,5-二溴-2-吡啶偶氨)-5-二乙氨基苯酚(3,5-diBr-PADAP)-Triton X-100析相光度体系,建立了矿石中微量铀的测定方法,在pH 7.5三乙醇胺-盐酸介质中,将胶束溶液在 95±1℃加热 1h.络合物即被Triton X-100相完全富集.络合物最大吸收峰位于565nm.摩尔吸光系数为1.02×10~5L·mol~(-1)·cm~(-1),铀含量在0~12μg/5mL服从比耳定律.采用TBP萃淋树脂分离干扰离子,测定矿石中微量铀,结果满意.  相似文献   

19.
根据新试剂2-(4-羧基苯偶氮)苯并噻唑(CPABT)与铂的显色反应及C8固相萃取小柱对显色络合物的固相萃取,建立了一种测定痕量铂的新方法,在pH为3.8~5.5的乙酸-乙酸钠缓冲介质中,在Tween-80存在下,铂与CPABT发生反应形成1∶1的稳定络合物,该络合物可用C8固相萃取小柱富集,小柱上富集的络合物用二甲基甲酰胺洗脱后用分光光度法测定,在富集后的测定液中,络合物最大吸收波长为508 nm,摩尔吸光系数ε=2.29×105L.mol-1.cm-1,Pt4 量在0.1~1.2μg/mL内符合比尔定律,方法已用于测定催化剂中的铂。  相似文献   

20.
本文研究了3,5-diCl-PADMA与钯的显色反应。在0.5~4.8mol/L HClO_4溶液中,试剂与钯形成稳定的1:1配合物,其最大吸收波长为616nm,表观摩尔吸光系数为8.38×10~4L·mol~(-1)·cm~(-1)。大量的铜、钴、镍及一定量贵金属离子不干扰钯的测定。所拟方法直接应用于含钯样品的分析。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号