首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A rapid and simple on-line method is described for the determination of Au(III) in various samples. The method is based on the sorption of gold(III) on Lewatit MonoPlus TP207 chelating resin including the iminodiacetate group, which is used as sorbent material and packed in a minicolumn. The chemical variables such as the pH of the sample solution, eluent type, interfering ions and concentrations of reagents, and instrumental variables such as sample loading volume, reagents flow rates, and tubing length, which affect the efficiency of the method were studied and optimised. Au(III) was sorbed on the chelating resin, from which it could be eluted with 3 mol L?1 HCl, and then introduced directly to the nebuliser-burner system of FAAS. The limit of detection of the method was 0.2 µg L?1 while the relative standard deviation was <4.0% for 20 µg L?1 Au(III) concentration. The preconcentration factor was found to be 106 while the optimised sample volume was 15.3 mL. The accuracy of the method was verified by analysing the certified reference material. The developed method was applied successfully for the determination of gold in different samples with satisfactory results.  相似文献   

2.
Iglesias M  Anticó E  Salvadó V 《Talanta》2003,59(4):651-657
A preconcentration method is developed for the on-line determination of palladium in complex matrices with flame atomic absorption spectrometry (FAAS). The flow system comprised of a minicolumn filled with polyamine Metalfix-Chelamine resin which is highly selective for Pt(IV), Au(III) and Pd(II). Best preconcentration conditions are established by testing different resin quantities, sample and eluent solution volumes, and adsorption and elution steps flow rates. Sample volumes of 4.7 ml of palladium solutions resulted in an enrichment factor of twenty at the optimum hydrodynamic conditions. This value can be increased by injecting larger volumes of sample solution. The method is sensitive, easy to operate and permitted the determination of sub-mg l−1 levels of palladium with a detection limit of 0.009 mg l−1. The resin was used up to 60 times in consecutive retention-elution cycles without any appreciable deterioration in its performance. The applicability of this method was tested by determining the palladium content in synthetic geological samples as well as in the pellet-type used car catalyst reference material.  相似文献   

3.
以大孔聚苯乙烯树脂为母体,通过-N=N-,与双硫腙键合,合成了双硫腙螯合型树脂,并将其应用于痕量铅和镉的同时分离富集,实验了酸度、流速、共存离子干扰等因素对双硫腙螯合型树脂吸附和洗脱Pb和Cd的影响,建立了双硫腙螯合型树脂同时分离富集-火焰原子吸收光度法测定食品及环境样品中痕量Pb和Cd的方法.对Pb和Cd,方法的检出限分别为0.015和0.0013μg/mL,相对标准偏差(RSD)均优于3.0%.  相似文献   

4.
A sensitive and selective method was developed for the determination of traces of manganese in urine using on-line electrochemical preconcentration followed by flame atomic absorption spectrometry detection. A home made flow-through polypropylene cell (4.5 cm long × 0.8 cm diameter filled with glass marbles) with an effective inner volume of 0.5 ml containing a working and a counter electrode, both of glassy carbon and a Pt pseudo reference electrode was located in a flow injection manifold specially designed for the purpose of this work. The manganese was deposited from buffer solution of NH3/NH4Cl at pH 9.00 through an oxidizing process at a current of 400 mA during 7 min. A flow of HCl 0.1 mol l−1 at 4 ml min−1 through the cell, chemically dissolved the deposit. A small portion (15 μl) of the concentrate was introduced in a continuously flowing system by means of a timing device and was then carried to the detector for the manganese quantification. All electrochemical and spectroscopic variables as well as possible interferences in both systems were systematically studied. The relative standard deviations for ten consecutive measurements of manganese solutions of 2.0 and 20 μg l−1 were of 2.3 and 1.5%, respectively, while for a sample processed five times was less then 5%. The accuracy of the developed procedure was evaluated by adding known amounts of manganese standard to urine samples and following the whole procedure. Recoveries within the range 97.2-102.8% were obtained. To further prove the accuracy, a Seronorm Trace Elements in Urine, Batch 403125 sample with a reported concentration of 13 μg Mn l−1 was also analyzed. The experimental value obtained was of 12.7 ± 0.1 μg l−1, which does not differ significantly from the reported amount (p < 0.05). A preconcentration factor of 40, a linear range between 0.015 and 60 μg l−1 and a limit of detection of 15 ng l−1 permitted the determination of manganese in real urine samples from non-exposed subjects in the range 0.5-2.8 μg l−1.  相似文献   

5.
Li Y  Jiang Y  Yan XP 《Talanta》2004,64(3):758-765
A further study on a newly developed flow injection (FI) on-line multiplexed sorption preconcentration (MSP) using a knotted reactor coupled with flame atomic absorption spectrometry (FAAS) was carried out to demonstrate its applicability and limitation for trace element determination. For this purpose, Cr(VI), Cu(II), Ni(II) and Co(II) were selected as the analytes, and detailed comparison was made between the MSP-FAAS and conventional FI on-line sorption preconcentration FAAS in respect to retention efficiency and linear ranges of absorbance versus sample loading flow rate and total preconcentration time. Introduction of an air-flow for removal of the residual solution in the KR after each sub-injection in the MSP procedure played a decisive role in the improvement of retention efficiency. The linearity of absorbance versus sample loading flow rate or total preconcentration time was extended to a more degree for the metal ions with less stability of their PDC (pyrrolidine dithiocarbamate) complexes than those with more stable PDC complexes. It seems that the MSP procedure behaves advantages beyond the inflection points in the diagrams of absorbance versus total preconcentration time and sample loading flow rate obtained by conventional (a single continuous) preconcentration procedure. With a sample loading flow rate of 6.0 ml min−1 and a total preconcentration time of 180 s, the retention efficiencies were increased from 25, 46, 41 and 63% with a single continuous sorption preconcentration to 44, 78, 65 and 75% with a six sub-injection preconcentration procedure for Cr(VI), Co(II), Ni(II), and Cu(II), respectively. The detection limits were 0.40, 0.33, 0.31 and 0.26 μg l−1 for Cr(VI), Co(II), Ni(II), and Cu(II), respectively. The precision (R.S.D.) for eleven replicate determination of 2 μg l−1 Cr(VI), Co(II) and Ni(II), and 1 μg l−1 Cu(II), was 2.1, 4.1, 2.6 and 1.7%, respectively.  相似文献   

6.
An automatic on-line system is developed for the trace determination of copper and iron species in fresh waters by flame atomic absorption spectrometry using only 5 and 2?mL of sample, for copper and iron determination, respectively. This system, which includes a home-made minicolumn of commercially available resin containing aminomethylphosphonic acid functional groups (Chelite P), comprises two operational modes. The first, used for the determination of the dissolved labile fraction (free copper and iron ions and their weak complexes) is based on the elution of this fraction from a minicolumn containing the chelating resin loaded in-situ with the sample. The second mode is used for the determination of total trace copper and iron concentrations. This last mode is based on the retention/preconcentration of total metals on the Chelite P resin after on-line sonoassisted digestion of water samples acidified with nitric acid (0.5?mol?L?1 final concentration) to break down metal organic complexes present in fresh waters as river waters. The figures of merit for copper and iron determination in both fractions are given and the obtained values are discussed. The analytical method was characterized and the limit of detection and limit of quantification for the two metals were 0.5 and 1.6?µg?L?1 for Cu and 2.3 and 6.1?µg?L?1 for Fe, respectively. The repeatability, expressed as relative standard deviation, was in the range 1.0–2.1%. The speciation scheme was applied to the analysis of river surface water samples collected in Galicia (Northwest, Spain).  相似文献   

7.
A flow system was coupled to a graphite furnace with a platform coated with tungsten-rhodium permanent chemical modifier for in-line separation and preconcentration of copper by employing a minicolumn loaded with 1-(2-tiazolylazo)-2-naphthol (TAN) immobilized on C18-bonded silica fixed in the tip of the autosampler arm. Elution was made by sampling 35 μl of 0.50 mol l−1 HCl with further delivering into a coated platform. Remarkable improvements in both selectivity and sensitivity were observed. Copper(II) was effectively separated from solutions containing up to 20 g l−1 Na+; 10 g l−1 K+, Ca2+ and Mg2+; 1.0 g l−1 Fe3+ and Zn2+. For a sample flowing at 3.0 ml min−1 and a loading of 60 s, the detection limit was estimated as 5 ng l−1 Cu(II) at the 99.7% confidence level, and an enrichment factor of 33 was calculated. Coefficient of variation was estimated as 4% for a 0.30 μg l−1 copper solution (n=20). The W-Rh permanent chemical modifier was used to improve system stability, analytical performance and atomizer lifetime. More than 1500 firings were carried out with the same atomizer without significant variations in sensitivity and precision. On account of the reagent immobilization, its consumption was lower than 0.2 μg per determination. In addition, TAN purification was unnecessary.  相似文献   

8.
强酸性条件下 ,钯 (Ⅱ )与 5 [( 5 氯 2 吡啶 )偶氮 ] 2 ,4 二氨基甲苯 ( 5 Cl PADAT)生成紫红色螯合物 ,该螯合物可与十二烷基苯磺酸钠 (SDBS)生成离子缔合物 ,离子缔合物经 0 .3μm孔径的硝化纤维微孔滤膜富集后 ,于小体积 ( 0 .5mL)的浓硫酸中溶膜 ,用石墨炉原子吸收法 (GFAAS)测定 ,富集倍数可达 2 0 0倍 ,钯含量在 4.69× 1 0 - 1 2 ~ 7.0 9× 1 0 - 9mol/L范围内线性良好 ,检出限为 1 .78×1 0 - 1 2 mol/L。方法用于海水中痕量钯的测定。  相似文献   

9.
1-(2-pryidylazo)-2-naphthol (PAN) immobilized on sodium dodecyl sulfate-coated nano alumina was developed for the preconcentration and determination of metal cations Co (II) from environmental and food samples. The research results displayed that adsorbent has the highest adsorption capacity for Co (II) in this system. Desorption by elution of the adsorbent with 2.0?ml of a mixture of nitric acid and ethanol was carried out. After phase separation, the enriched analyte in the final solution is determined by flame atomic absorption spectrometry (FAAS) by using a micro sample introduction system. Analytical influencing parameters including pH value, amount of sorbent, equilibrium time, sample volume, volume and concentration of eluent were examined. The effect of common matrix ions has also been investigated and it was found that they had no influence on cobalt preconcentration. Under the optimum experimental conditions, the maximum capacity of sorbent was obtained as 20?mg?g?1. The preconcentration factor and limit of detection were found to be 250 and 0.15?µg?L?1, respectively. This method showed good precision with the relative standard deviation (RSD) of 2.4% and 2.1% in concentrations of 20 and 50?µg?L?1, respectively. The accuracy of the method was evaluated by comparison of results with those obtained by electrothermal atomic absorption spectrometry. This method was successfully applied for preconcentration and determination of Co (II) in environmental and food samples.  相似文献   

10.
Expanded polystyrene (EPS) foam waste (white pollutant) was utilised for the synthesis of novel chelating resin i.e. EPS-N = N-α-Benzoin oxime (EPS-N = N-Box). The synthesised resin was characterised by FT-IR spectroscopy, elemental analysis, and thermogravimetric analysis. A selective method for the preconcentration of Pb(II) ions on EPS-N = N-Box resin packed in mini-column was developed. The sorbed Pb(II) ions were eluted with 5.0 mL of 2.0 mol L?1 HCl and determined by microsample injection system coupled flame atomic absorption spectrometry (MIS-FAAS). The average recovery of Pb(II) ions was achieved 95.5% at optimum parameters such as pH 7, resin amount 400 mg, flow rates 1.0 mL min?1 (of eluent) and3.0 mL min?1 (of sample solution). The total saturation capacity of the resin, limit of detection (LOD) and limit of quantification (LOQ) of Pb(II) ions were found to be 30 mg g?1, 0.033 μg L?1 and 0.107 μg L?1, respectively with preconcentration factor of 300. The accuracy, selectivity and validation of the method was checked by analysis of sea water (BCR-403), wastewater (BCR-715) and Tibet soil (NCS DC-78302) as certified reference materials (CRMs). The proposed method was applied successfully for the trace determination of Pb(II) ions in aqueous samples.  相似文献   

11.
A switchable solvent-based micro-extraction method for pre-concentration and separation of ultratrace palladium was developed prior to its flame atomic absorption spectrometric detection. Reverse change of hydrophilicity of N,N-dimethylcyclohexylamine (DMA) was achieved by reaction with carbonated water. The hydrophilic bicarbonate salt of the protonated DMA was used as extractant for palladium complexed with 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol (5-Br-PADAP). Formation of the hydrophobic form of switchable solvent from hydrophilic form of switchable solvent phase was achieved by addition of sodium hydroxide into the extractant-sample solution. The effect of key parameters affected extraction recovery was studied and optimised by using Plackett–Burman design, central composite design and three dimension (3D) surfaces response. The calibration plot was linear in the range 0.015–1.6 mg L?1 of palladium with a correlation coefficient of 0.999. The limit of detections values of palladium for liquid and solid samples were 4.28 μg L?1 and 0.54 µg g?1, respectively. The pre-concentration factor was 37.5. The accuracy was confirmed by determination of palladium in certified reference material. The procedure was also applied for determination of palladium content of real samples as automotive catalytic converter, roadside dust, sea water and river water.  相似文献   

12.
Six chelating matrices have been prepared by anchoring 2,3-dihydroxypyridine (DHP) and 2-{[1-(3,4-dihydroxyphenyl)methylidene]amino}benzoic acid (DMABA) onto Amberlite XAD-2 and XAD-16 and 3,4-dihydroxybenzaldehyde (DHB), and iminodiacetic acid (IDA) onto silica gel. The materials were explored for enrichment of palladium followed by its determination with flame AAS. The optimum pH ranges for quantitative solid phase extraction by these matrices are from 4.0–5.5 to 5.5–7.0. The flow rates (column procedure) and concentration of HCl required for desorption have been optimized. Thiourea (∼3%) is essential for quantitative recovery of Pd. The t1/2 values are between 5 and 15 min. The sorption capacity varies from 38 to 192 μmol g−1 (highest for silica gel loaded with iminodiacetic acid). The preconcentration factors were found in the range 20–150. Tolerance limits of foreign species in the enrichment are reported. The enrichment procedures coupled with FAAS determinations were applied to synthetic solutions corresponding to standards GBW07293 and NIST SRM 2557 successfully.  相似文献   

13.
提出了以732强酸型阳离子树脂作填充材料,流动注射在线离子交换预富集火焰原子吸收光谱法测定水样中微量锰的分析方法。优化了各项化学条件和流路参数等,考察了共存离子的干扰。富集倍数可达24倍,分析速度为15~20样/h,检出限为2.0ng/mL,相对标准偏差为2.8%(n=15)。对雨水加标回收,回收率为97%~103%。  相似文献   

14.
A fully automated procedure for the determination of ng l−1 amounts of lead has been developed using flow injection (FI) online column preconcentration coupled with electrothermal atomic absorption spectrometry (ETAAS). The proposed FI manifold and its operation make possible the introduction of the total eluate volume into the graphite atomizer, avoiding the necessity for optimization of subsampling the eluate. The interference of other heavy metal ions due to competition for active sites of the sorbent is overcome using a highly selective macrocycle immobilized on silica gel (Pb-02). Lead is adsorbed on a microcolumn (50 μl) packed with Pb-02, and after washing the column with dilute nitric acid, air is introduced to remove all solution from the column and connecting tubing. The sorbed analyte is then eluted quantitatively into the graphite tube atomizer, preheated to 100°C, with 36 μl of ETDA solution (0.035 mol l−1, pH 10.5), propelled by air in order to minimize dispersion. The collection efficiency was 77% and with a sample loading flow rate of 3 ml min−1 and a 60 s preconcentration time, the enhancement factor was 77 and the throughput was 17 samples per hour. The relative standard deviation (n = 10) at the 300 ng l−1 level was 2.7%, and the detection limit (3σ) was 0.4 ng l−1. No interference from heavy metals was observed, but ions of Ba2+, Sr2+ and K+ were found to interfere when the concentration ratios of interferent to lead exceeded values of 2000, 20 000 and 200 000, respectively. Quantitative recovery of lead was achieved from sodium, magnesium, aluminum, lanthanum and heavy metal salt solutions. The high selectivity and sensitivity, combined with extremely low blank values, make the proposed technique particularly attractive for the analysis of high-purity reagents, semiconductors and other high-purity materials. Results are presented for the determination of lead in some high-purity reagents.  相似文献   

15.
A solvent impregnated hollow fibre (SIHF) module has been developed for the preconcentration of lead by using bis(2-ethylhexyl) phosphoric acid (DEHPA) dissolved in kerosene as extractant. The module has been designed for an on-line determination of trace amounts of lead(II) at mg l−1 (ppm) level by flame atomic absorption spectrometry (FAAS).

The SIHF system is based on the metal liquid–liquid distribution between aqueous solutions of different acidity and the mentioned organic solution. The highest enrichment factor of Pb(II) was determined at pH=4.0 using a formic acid/formiate buffer solution.

Preconcentration experiments were carried out at low lead(II) concentration (mg l−1 level) by using the SIHF module. This study includes the influence of hydrodynamic and chemical conditions on the loading and elution of Pb(II) on the SIHF, i.e., flow rate through the fibres, acidity of the eluent (as nitric acid concentration) and the chemical nature of the acid used in the elution. Breakthrough curves were determined for different sampling flow rates, 0.54 ml min−1 was selected to minimise the loading volume of Pb(II) sample. 0.1 M nitric acid was chosen as eluent solution, and perchloric acid also shows appropriate elution characteristics. The degree of concentration obtained for Pb(II) are of 10 fold the original concentration. The quantification limit for Pb(II) achieved with this preconcentration system is 0.17 mg l−1.

The results obtained indicate that the SIHF system can be applied for on-line determination of trace amounts of lead(II) by FAAS.  相似文献   


16.
A simple and practical preconcentration method using cloud point approach is proposed for the extraction and preconcentration of Cu (II). The analyte in the initial aqueous solution, acidified with HCl, is complexed with O,O-diethyldithiophosphate and Triton X-100 is added as a surfactant. After phase separation at 40°C based on cloud point of the mixture and dilution of the surfactant-rich phase with methanol, the enriched analyte is determined by flame atomic absorption spectrometry using conventional nebulization and the analytical wavelength used is 324.8 nm. The variables affecting the complexation and extraction steps were optimized. Under optimum conditions, preconcentration of 10 ml of sample in the presence of 0.1% (v/v) Triton X-100 permitted the detection of 0.94 ng ml−1 of Cu. Analytical graphs were rectilinear in the concentration range of 5-200 ng ml−1 and relative standard deviations were lower than 3%. The method affords recoveries in the range 97-101%. The method was successfully applied to the determination of Cu in drinking and rainwater, serum and human hair samples.  相似文献   

17.
Manganese is extracted on-line from solid seafood samples by a simple continuous ultrasound-assisted extraction system (CUES). This system is connected to an on-line manifold, which permits the flow-injection flame atomic absorption spectrometric determination of manganese. Optimisation of the continuous leaching procedure is performed by an experimental design. The proposed method allows the determination of manganese with a relative standard deviation of 0.9% for a sample containing 23.4 μg g−1 manganese (dry mass). The detection limit is 0.4 μg g−1 (dry mass) for 30 mg of sample and the sample throughput is ca. 60 samples per hour. Accurate results are obtained by measuring TORT-1 certified reference material. The procedure is finally applied to mussel, tuna, sardine and clams samples.  相似文献   

18.
Rojas FS  Ojeda CB  Pavón JM 《Talanta》2006,70(5):979-983
A flow injection (FI) system was used to develop an efficient on-line sorbent extraction preconcentration system for palladium by graphite furnace atomic absorption spectrometry (GFAAS). The investigated metal was preconcentrated on a microcolumn packed with 1,5-bis(di-2-pyridyl)methylene thiocarbohydrazide immobilized on silica gel (DPTH-gel). The palladium is eluted with 40 μl of HCl 4 M and directly introduced into the graphite furnace. The detection limit for palladium under the optimum conditions was 0.4 ng ml−1. This procedure was employed to determine palladium in different samples.  相似文献   

19.
A modified SBA-15 mesoporous silica material NH2-SBA-15 was synthesized successfully by grafting γ-aminopropyl-triethoxysilane. The material was characterized using transmission electron microscopy (TEM) and Fourier transform infrared/Raman (FT-IR/Raman) spectroscopy, and used for the first time in a flow injection on-line solid phase extraction (SPE) coupled with flame atomic absorption spectrometry (FAAS) to detect trace Cr (VI). Effective sorption of Cr (VI) was achieved at pH 2.0 with no interference from Cr (III) and other ions and 0.5 mol L−1 NH3·H2O solution was found optimal for the complete elution of Cr (VI). An enrichment factor of 44 and was achieved under optimized experimental conditions at a sample loading of 2.0 mL min−1 sample loading (300 s) and an elution flow rate of 2.0 mL min−1 (24 s). The precision of the 11 replicate Cr (VI) measurements was 2.1% at the 100 μg L−1 level with a detection limit of 0.2 μg L−1 (3 s, n = 10) using the FAAS. The developed method was successfully applied to trace chromium determination in waste water. The accuracy was validated using a certified reference material of riverine water (GBW08607).  相似文献   

20.
A method for the quantitative preconcentration of lead based on an existing batch process was developed for implementation in a flow system including a flame AAS detector. Lead can be quantitatively preconcentrated as pyrrolidinedithiocarbamate or dithizonate on an activated carbon minicolumn. The chelates are eluted in methyl isobutyl ketone and introduced directly into the nebuliser-burner. An enrichment factor of 50 is typically obtained for a preconcentration time of 2 min (lead can be determined at concentrations between 15 and 400 ng/ml), which results in a throughput of ca. 25 samples per hr. The sensitivity achieved with the two reagents is similar, but the selectivity provided by APDC exceeds that of dithizone. Based on the results obtained in the determination of lead in reference materials (minerals and skim milk), the proposed APDC method is applicable to real samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏