首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 28 毫秒
1.
A 4-Amino-2-mercaptopyrimidine self-assembled monolayer (AMP SAMs/Au) modified gold electrode was prepared. The electrochemical behavior of acetaminophen on the AMP SAMs/Au was studied in Britton-Robinson (BR) buffer solution. Compared to a bare gold electrode, the modified electrode exhibits a significant enhancement in the oxidation current response for acetaminophen. The modified electrode was used for the determination of acetaminophen by square wave voltammetry. The oxidation current increased linearly with the concentration of acetaminophen in the range of 2.0 × 10−6−4.0 × 10−3 M. The modified electrode made it possible to eliminate the interference of dopamine (DA), brucine, epinephrine (EP), and norepinephrine (NE). The practical analytical utility was illustrated by the determination of acetaminophen in a commercially available drug. The text was submitted by the authors in English.  相似文献   

2.
Polythymine oligonucleotide (PTO)‐modified gold electrode (PTO/Au) was developed for selective and sensitive Hg2+ detection in aqueous solutions. This modified electrode was prepared by self‐assembly of thiolated polythymine oligonucleotide (5′‐SH‐T15‐3′) on the gold electrode via Au? S bonds, and then the surface was passivated with 1‐mercaptohexanol solution. The proposed electrode utilizes the specific binding interactions between Hg2+ and thymine to selectively capture Hg2+, thereby reducing the interference from coexistent ions. After exchanging the medium, electrochemical reduction at ?0.2 V for 60 s, voltammetric determination was performed by differential pulse voltammetry using 10 mM HEPES; pH 7.2, 1 M NaClO4 as supporting electrolyte. This electrode showed increasing voltammetric response in the range of 0.21 nM Hg2+, with a relative standard deviation of 5.32% and a practical detection limit of 60 pM. Compared with the conventional stripping approach, the modified electrode exhibits good sensitivity and selectivity, and is expected to be a new type of green electrode.  相似文献   

3.
Contamination of natural water by mercury (Hg2+) and bismuth (Bi3+) metal ions have been extensively studied due to their toxic effects. A validated square-wave anodic stripping voltammetry (SW-ASV) method for determining Bi3+ and Hg2+ ions individually and simultaneously is described. A new electrochemical sensor was constructed using a gold (Au) electrode that has been modified with poly(1,2-diaminoanthraquinone) (p-1,2-DAAQ). Scanning electron microscopy, cyclic voltammetry, and electrochemical impedance spectroscopy were used to characterize the p-1,2-DAAQ/Au modified electrode. Factors such as the polymer film thickness, electrolyte, square wave parameters and preconcentration conditions were optimized to improve the performance of the modified Au electrode. Good linear responses were achieved in the concentration ranges of 1–200 μg L−1 and 1–50 μg L−1 forBi3+ and Hg2+, respectively, and the limits of detection were 0.27 μg L−1 (Bi3+) and 0.29 μg L−1 (Hg2+). The interference study results illustrated the high selectivity of the modified electrode for detection of Bi3+ and Hg2+. The proposed SW-ASV method was successfully applied for Bi3+ and Hg2+analyses in different real water samples.  相似文献   

4.
界面可控硫醇SAMs纳米金修饰金电极的电化学行为研究   总被引:1,自引:0,他引:1  
在裸金电极上自组装不同比例的4,4’-二甲基联苯硫醇(MTP)和硫辛酸(TA)混合液,形成自组装膜(MTP+TA/Au SAMs),再修饰纳米金,制得纳米金混合巯基修饰金电极(AuNPs/MTP+TA/Au)。研究了纳米金混合巯基修饰金电极的电化学行为和阻抗行为,结果表明电极表面pH值的改变对电极表面的电子转移有重要影响。对葡萄糖传感器的制备条件、测定条件、抗干扰能力等进行了讨论,结果表明修饰电极的微结构和微环境有必要进一步研究。  相似文献   

5.
A novel and sensitive electrochemical method for determination of mercury (II) ions (Hg2+) based on the formation of thymine–Hg2+–thymine complexes and gold nanoparticle-mediated signal amplification is reported. Two 5′ end thiolated complementary oligonucleotides containing six strategically placed thymine–thymine mistakes were introduced in this work. One of the two oligonucleotides was immobilized on a gold electrode and the other one on gold nanoparticles (AuNPs). Due to six thymine–thymine mistakes the two oligonucleotides were not able to be hybridized, so AuNPs could not be immobilized onto the electrode surface after the electrode was immersed in the DNA–AuNPs solution. However, if Hg2+ existed, T–Hg2+–T complexes could be formed and AuNPs could be immobilized onto the electrode surface. Meanwhile, large numbers of [Ru(NH3)6]3+ molecules as electrochemical species could be localized onto the electrode surface. The Hg2+ detection limit of this assay could be as low as 10 nM, which is the US Environmental Protection Agency (EPA) limit of Hg2+ for drinkable water. This method is proven to be simple, convenient, high sensitive and selective.  相似文献   

6.
In this paper, a simple, selective and reusable electrochemical biosensor for the sensitive detection of mercury ions (Hg2+) has been developed based on thymine (T)-rich stem–loop (hairpin) DNA probe and a dual-signaling electrochemical ratiometric strategy. The assay strategy includes both “signal-on” and “signal-off” elements. The thiolated methylene blue (MB)-modified T-rich hairpin DNA capture probe (MB-P) firstly self-assembled on the gold electrode surface via Au–S bond. In the presence of Hg2+, the ferrocene (Fc)-labeled T-rich DNA probe (Fc-P) hybridized with MB-P via the Hg2+-mediated coordination of T–Hg2+–T base pairs. As a result, the hairpin MB-P was opened, the MB tags were away from the gold electrode surface and the Fc tags closed to the gold electrode surface. These conformation changes led to the decrease of the oxidation peak current of MB (IMB), accompanied with the increase of that of Fc (IFc). The logarithmic value of IFc/IMB is linear with the logarithm of Hg2+ concentration in the range from 0.5 nM to 5000 nM, and the detection limit of 0.08 nM is much lower than 10 nM (the US Environmental Protection Agency (EPA) limit of Hg2+ in drinking water). What is more, the developed DNA-based electrochemical biosensor could be regenerated by adding cysteine and Mg2+. This strategy provides a simple and rapid approach for the detection of Hg2+, and has promising application in the detection of Hg2+ in real environmental samples.  相似文献   

7.
Herein, a simple electrochemical sensor was fabricated for sensing Hg2+ ions by using electrochemically reduced p‐nitrobenzoic acid molecules modified (ERpNBA) glassy carbon electrode (GCE). The modified electrode was applied for the determination of Hg2+ ions by using differential pulse anodic stripping voltammetry (DPASV). Experimental parameters such as concentration of p‐nitrobenzoic acid used for electrode modification, pH, accumulation time and deposition potential used for the determination of Hg2+ ions were optimized. The strong interaction between the Hg2+ ions and the lone pair of electrons on the nitrogen atoms of ERpNBA molecules leads to highly selective adsorption of Hg2+ ions on the modified electrode. Under the optimum experimental conditions, the sensor showed higher sensitivity and very low detection limit for Hg2+ ions than other metal ions such as Cd2+, Pb2+ and Zn2+ ions. The LOD for Hg2+ ions was 240 pM which is below the guideline value given by the World Health Organization and the earlier reports.  相似文献   

8.
《Electroanalysis》2017,29(9):2090-2097
Lignosulfonate‐stabilized gold nanoparticles (AuNPs‐LS) were synthesized and subsequently used as a complexing agent for mercury ions. The obtained AuNPs‐LS/Hg2+ complex was characterized by means of various physicochemical techniques such as UV‐vis spectroscopy, transmission electron microscopy and cyclic voltammetry. Furthermore, the resulting complex was evaluated as an electrode modifier for the development of amperometric sensors. Upon sufficient negative potential, the bound mercury ions are reduced to form an amalgam with AuNPs‐LS. Thus, the performance of glassy carbon electrode (GCE) modified by AuNPs‐LS/Hg film was investigated as an electrochemical sensor in the determination of Tl+ ions in a 0.05 M EDTA at pH 4.5. The presence of the mercury containing film improves the analyte accumulation due to its ability to form a fused amalgam with thallium. The presented data indicate that the GCE/AuNPs‐LS/Hg modified electrode shows better performance toward Tl+ determination in comparison to bare GCE. The stripping anodic peak current of thallium was linear over its concentration range from 1.7⋅10−7 to 5.0⋅10−6 M. The detection limit (3σ) was estimated to be 1.4⋅10−7 M. The proposed method was successfully applied for the determination of thallium ions in real samples of soil derived from the area of the copper smelter near Głogów (Poland).  相似文献   

9.
《Analytical letters》2012,45(14):2327-2343
Abstract

A novel approach for the voltammetric determination of Pb2+, Cu2+, and Hg2+ in the presence of macromolecule contaminants was developed. An Au nanoparticles array was directly electrodeposited onto the gold electrode surface followed by a further modification of a mercaptoethanesulfonate (MES) monolayer. Square wave stripping voltammetry (SWSV) of Pb2+, Cu2+, and Hg2+ was performed on the doubly modified electrode. The electrodeposited gold nanoparticles provided a significantly improved sensitivity. Simultaneously, the MES monolayer efficiently prevented the macromolecules accessing the electrode surface. Compared with the bare gold electrode, the doubly modified electrode has the ability to detect metal ions in the presence of macromolecule contaminants, even when their concentration reach 100 ppm. Under the optimal conditions, the detection limits of 0.16, 0.15, and 0.14 ppb for Pb2+, Cu2+, and Hg2+ were obtained, respectively. The calibration graphs were linear in the concentration range of 1–100 ppb. The results of the analysis of a real metallurgy wastewater sample were reported. The electrode system has a great potential for the direct determination of trace metals in the complex environment and biological samples.  相似文献   

10.
A novel electrochemical biosensor with high sensitivity and selectivity for mercuric ion detection, based on DNA self-assembly electrode, is designed. Thiol functionalized poly-T oligonucleotides were used as gold electrode modifier through formation of Au–S bond between DNA and gold electrode. In presence of Hg2+ ions, the specific coordination between Hg2+ and thymine bases can change parallel ss-DNA from linear to hairpin structures, which can cause the release of partial DNA molecules from the surface of the electrode. The density of DNA on the surface of electrode correlated with the concentration of mercury in the solution and can be monitored by electrochemical impedance spectroscopy. The limit of detection of this method is pM level of mercuric ions which is far below the upper limit of Hg2+ mandated by United States Environmental Protection Agency (EPA), 2 ppb (10 nM). In addition, this method showed excellent selectivity. A series of divalent metal ions, including Ni2+, Co2+, Mg2+, Zn2+, Ba2+ and Cd2+, have little interference with the detection of Hg2+.  相似文献   

11.
A new chemically modified carbon paste electrode by 2,2?-((pyridine-2,6-diylbis(azanylylidene))bis(methanylylidene))diphenol (L) ligand has been made and used as a sensor for determination of trace mercury and cadmium ions with cyclic voltammetry (CV) and differential pulse voltammetry (DPV) methods. Complexation studies of the ligand with Cu2+, Zn2+, Hg2+, Ni2+ and Cd2+ ions by conductometric method in acetonitrile–ethanol mixture at 25°C show that the ML complexes have formed. The formation constants of complexes were calculated from the computer fitting of the molar conductance–mole ratio data, and the stability of the resulting complexes varied in order of Cd2+ > Hg2+ > Cu2+ > Zn2+ > Ni2+. Then a simple and effective chemically modified carbon paste electrode with L was prepared, and the electrochemical properties and applications of the modified electrode were investigated. Under the optimal conditions, the detection limit was 0.0494 μg L?1 and 0.0782 μg L?1 for cadmium and mercury ions, respectively, and the linear range for both metal ions were from 1 to 100 μg L?1. The electrode shows high sensitivity, reproducibility and low cost, and was successfully applied to determination of Cd2+ and Hg2+ ions in water samples with recovery in the range of 97–101%.  相似文献   

12.
In this paper, an electrochemical aptamer sensor was proposed for the highly sensitive detection of mercury ion (Hg2+). Carbon nanofiber (CNF) was prepared by electrospinning and high‐temperature carbonization, which was used for the loading of platinum nanoparticles (PtNPs) by the hydrothermal method. The Pt@CNF nanocomposite was modified on the surface of carbon ionic liquid electrode (CILE) to obtain Pt@CNF/CILE, which was further decorated by gold nanoparticles (AuNPs) through electrodeposition to get Au/Pt@CNF/CILE. Self‐assembling of the thiol‐based aptamer was further realized by the formation of Au‐S bond to get an electrochemical aptamer sensor (Aptamer/Au/Pt@CNF/CILE). Due to the specific binding of aptamer probe to Hg2+ with the formation of T‐Hg2+‐T structure, a highly sensitive quantitative detection of Hg2+ could be achieved by recording the changes of current signal after reacting with Hg2+ within the concentration range from 1.0 × 10?15 mol/L to 1.0 × 10?6 mol/L and the detection limit of 3.33 × 10?16 mol/L (3σ). Real water samples were successfully analyzed by this method.  相似文献   

13.
A new chemically modified carbon paste electrode was constructed and used for rapid, simple, accurate, selective and highly sensitive simultaneous determination of cadmium, copper and mercury using square wave anodic stripping voltammetry (SWASV). The carbon paste electrode was modified by N,N′-bis(3-(2-thenylidenimino)propyl)piperazine coated silica nanoparticles. Compared with carbon paste electrode, the stripping peak currents had a significant increase at the modified electrode. Under the optimized conditions (deposition potential, −1.100 V vs. Ag/AgCl; deposition time, 60 s; resting time, 10 s; SW frequency, 25 Hz; pulse amplitude, 0.15 V; dc voltage step height, 4.4 mV), the detection limit was 0.3, 0.1 and 0.05 ng mL−1 for the determination of Cd2+, Cu2+ and Hg2+, respectively. The complexation reaction of the ligand with several metal cations in methanol was studied and the stability constants of the complexes were obtained. The effects of different cations and anions on the simultaneous determination of metal ions were studied and it was found that the electrode is highly selective for the simultaneous determination of Cd2+, Cu2+ and Hg2+. Furthermore, the present method was applied to the determination of Cd2+, Cu2+ and Hg2+ in water and some foodstuff samples.  相似文献   

14.
A label-free electrochemical detection protocol for DNA hybridization is reported for the first time by using a gold electrode (AuE). The oxidation signal of guanine was monitored at +0.73 V by using square wave voltammetry (SWV) on self-assembled l-cysteine monolayer (SAM) modified AuE. The electrochemical determination of hybridization between an inosine substituted capture probe and native target DNA was also accomplished. 6-mer adenine probe was covalently attached to SAM via its amino link at 5 end. Then, 6-mer thymine-tag of the capture probe was hybridized with the adenine probe, thus left the rest of the oligonucleotide available for hybridization with the target. The dependence of the guanine signal upon the concentration of the target was observed. Probe modified AuE was also challenged with non-complementary and mismatch containing oligonucletides. Label-free detection of hybridization on AuE is greatly advantageous over the existing carbon and mercury electrode materials, because of its potential applicability to microfabrication techniques. Performance characteristics of the genosensor are described, along with future prospects.  相似文献   

15.
An ultra-sensitive and highly selective electrochemical label-free aptasensor is proposed for the quantitation of Hg2 + based on the hybridization/dehybridization of double-stranded DNA (dsDNA) on a gold electrode. Thiol-substituted single-stranded DNA (ssDNA) is self-assembled on the gold electrode surface through the SAu interaction. The hybridization of ssDNA with complementary DNA (cDNA) and the consequences of dehybridization in the presence of mercury ions are followed through differential pulse voltammetry (DPV) responses using a [Fe(CN)6]3 −/4  redox probe. The formation of a thymine–Hg2 +–thymine (T–Hg2 +–T) complex is the key to producing a highly selective and sensitive aptasensor for Hg2 + determination. Specifically, the present electrochemical aptasensor is able to quantify Hg2 + ions in concentrations from 5 zeptomolar (zM) to 55 picomolar (pM) with a limit of detection of 0.6 zM, close to the dream of single atom detection, without requiring a complicated procedure or expensive materials.  相似文献   

16.
Min Zheng  Yiming Zhou  Yawen Tang  Tianhong Lu 《Talanta》2010,81(3):1076-16091
The surface coverage of 3-mercaptopropylphosphonic acid (HS-CH2CH2CH2-PO3H2, MPPA) self-assembled monolayers (SAMs) on gold surface can be controlled by the dissociation degree of phosphonic acid groups (-PO3H2) in the bulk solution and adsorption time of MPPA molecules under the basic condition. Electrochemical measurements show that the low-density MPPA-SAMs modified gold electrode enhances significantly the kinetics of electron transfer of dopamine (DA), and improves the antifouling capability of modified electrode towards DA oxidation. The present results offer crucial information for design and optimization of the electrochemical sensors for DA determination.  相似文献   

17.
Gold nanoparticles (GNs) could be efficiently immobilized on binary mixed self-assembled monolayers (SAMs) on a gold surface composed of 1,6-hexanedithiol and 1-octanethiol (nano-Au/SAMs gold electrode). This GN chemically modified electrode was used for electrochemical determination of ascorbic acid (AA) and dopamine (DA) in aqueous media. The result showed that the GN-modified electrode could clearly resolve the oxidation peaks of AA and DA, with a peak-to-peak separation (∆E p) of 110 mV enabling determination of AA and DA in the presence of each other. The linear analytical curves were obtained in the ranges of 0.3–1.4 mM for AA and 0.2–1.2 mM for DA concentrations using differential pulse voltammetry. The detection limits (3σ) were 9.0 × 10−5 M for AA and 9.0 × 10−5 M for DA.  相似文献   

18.
Book reviews     
Inorganic mercury ions (Hg2+) in laboratory prepared solutions were determined with a screen-printed carbon electrode (SPCE) coated with a polyaniline-methylene blue (PANI-MB) polymer layer. The structure and properties of the PANI-MB polymer layer were compared to that of normal polyaniline (PANI) in order to elucidate the structure of the PANI-MB layer. The electrically-conducting polymers were prepared by electrochemical polymerisation of monomer solutions of aniline, and mixed solutions of aniline with methylene blue onto respective screen-printed carbon electrodes (SPCEs). Scanning Electron Microscopy (SEM) analyses of the SPCE polymer coated electrodes have shown that nanostructured materials have formed with the diameters of the PANI nanoclusters and PANI-MB nanorods at approximately 200 nm. Anodic stripping voltammetry (ASV) was used to evaluate a solution composed of 1 × 10?6 M Hg2+, in the presence of the SPCE/PANI-MB polymer sensor electrode. The Hg2+ ions were determined as follows: (i) pre-concentration and reduction on the modified electrode surface and (ii) subsequent stripping from the electrode surface during the positive potential sweep. The experimental conditions optimised for Hg2+ determination included the supporting electrolyte concentration and the accumulation time. The results obtained have shown that the SPCE/PANI-MB polymer sensor electrode operates optimally at a pH 2, with the supporting electrolyte concentration at 0.5 M HCl. A linear calibration curve was found to be in the range of 1 × 10?8 M to 1 × 10?5 M Hg2+ after 120 s of pre-concentration. The detection limit was calculated and found to be 54.27 ± 3.28 µg L?1 of Hg2+. The results have also shown that a conducting polymer modified SPCE sensor electrode can be used as an alternative transducer for the voltammetric stripping and analysis of inorganic Hg2+ ions.  相似文献   

19.
Engineered nucleic acid probes containing recognition and signaling functions find growing interest in biosensor design. In this paper, we developed a novel electrochemical biosensor for sensitive and selective detecting of Hg2+ based on a bifunctional oligonucleotide signal probe combining a mercury-specific sequence and a G-quadruplex (G4) sequence. For constructing the electrochemical Hg2+ biosensor, a thiolated, mercury-specific oligonucleotide capture probe was first immobilized on gold electrode surface. In the presence of Hg2+, a bifunctional oligonucleotide signal probe was hybridized with the immobilized capture probe through thymine–mercury(II)–thymine interaction-mediated surface hybridization. The further interaction between G4 sequence of the signal probe and hemin generated a G4–hemin complex, which catalyzed the electrochemical reduction of hydrogen peroxide, producing amplified readout signals for Hg2+ interaction events. This electrochemical Hg2+ biosensor was highly sensitive and selective to Hg2+ in the concentration of 1.0 nM to 1 μM with a detection limit of 0.5 nM. The new design of bifunctional oligonucleotide signal probes also provides a potential alternative for developing simple and effective electrochemical biosensors capable of detecting other metal ions specific to natural or artificial bases.  相似文献   

20.
In our study, the single‐use & eco‐friendly electrochemical sensor platform based on herbal silver nanoparticles (AgNPs) was developed for detection of mercury (II) ion (Hg2+). For this purpose, the surface of pencil graphite electrode (PGE) was modified with AgNPs and folic acid (FA), respectively. The concentrations of AgNPs and FA were firstly optimized by differential pulse voltammetry (DPV) to obtain an effective surface modification of PGE. Each step at the surface modification process was characterized by using cyclic voltammetry (CV) and electrochemical impedence spectroscopy (EIS). The limit of detection (LOD) for Hg2+ was estimated and found to be 8.43 μM by CV technique. The sensor presented an excellent selectivity for Hg2+ against to other heavy metal ions such as Ca2+, Cd2+, Cr3+, Cu2+, Mg2+, Ni2+, Pb2+, Zn2+, Co2+ and Mn2+. Moreover, a rapid, selective and sensitive detection of Hg2+ was successfully performed in the samples of tap water within 1 min.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏