首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A rapid and sensitive method has been developed for the determination of biphenyl and biphenyl oxide in water samples using dispersive liquid–liquid microextraction followed by gas chromatography. This method involves the use of an appropriate mixture of extraction solvent (8.0?µL tetrachloroethylene) and disperser solvent (1.0?mL acetonitrile) for the formation of cloudy solution in 5.0?mL aqueous sample containing biphenyl and biphenyl oxide. After extraction, phase separation was performed by centrifugation and biphenyl and biphenyl oxide in sedimented phase (5.0?±?0.3?µL) were determined by gas chromatography-flame ionisation (GC-FID) system. Type of extraction and disperser solvents and their volumes, salt effect on the extraction recovery of biphenyl and biphenyl oxide from aqueous solution have been investigated. Under the optimum conditions and without salt addition, the enrichment factors for biphenyl and biphenyl oxide were 819 and 785, while the extraction recovery were 81.9% and 78.5%, respectively. The linear range was (0.125–100?µg L?1) and limit of detection was (0.015?µg?L?1) for both analytes. The relative standard deviation (RSD, n?=?4) for 5.0?µg?L?1 of analytes were 8.4% and 6.7% for biphenyl and biphenyl oxide, respectively. The relative recoveries of biphenyl and biphenyl oxide from sea, river water and refined water (Paksan company) samples at spiking level of 5.0?µg?L?1 were between 85.0% and 100 %.  相似文献   

2.
In this study, a simple and efficient method of ligandless-ultrasound-assisted emulsification microextraction (LL-USAEME) followed by inductively coupled plasma-optical emission spectrometry (ICP-OES) has been developed for simultaneous extraction, preconcentration and determination of manganese, cadmium, cobalt and nickel in water samples. In the proposed approach, tetrachloroethylene was selected as extraction solvent. The effect of important experimental factors such as volume of extraction solvent, pH, sonication time, salt concentration, and temperature was investigated by using a fractional factorial design (25?1) to identify important factors and their interactions. In the next step, a Box-Behnken design (BBD) was applied for optimisation of significant factors. The obtained optimal conditions were: 30?µL for extraction solvent, 12 for pH, 5?min for sonication time, and 5% w/v for salt concentration. The limits of detections (LODs) for Cd(II), Co(II), Mn(II) and Ni(II) were 0.20, 0.13, 0.21 and 0.28?µg?L?1, respectively. Relative standard deviations (RSD, C?=?200.0?µg?L?1, n?=?9) were between 3.4–7.5% and the calibration graphs were linear in the range of 0.25 to 1000.0?µg?L?1 for Mn, 0.5–1000.0?µg?L?1 for Co and Ni and 1.0–250.0?µg?L?1 for Cd. The determination coefficients (R 2) of the calibration curves for the analytes were in the range of 0.993 to 0.999. The proposed method was validated by using two certified reference materials, and also the method was applied successfully for the determination of heavy metals in different real water samples.  相似文献   

3.
In the present study, room-temperature ionic liquid (RTIL) 1-butyl-3-methylimidazolium hexafluorophosphate was used as extraction solvent in a liquid–liquid microextraction (LLME) procedure followed by liquid chromatography for determining 4-nonylphenol (4-NP) and 4-tert-octylphenol (4-t-OP) in environmental water samples. RTIL-based LLME was a simple, inexpensive, and fast sample preparation method, and its parameters such as extraction time, addition of salt, selection of phase ratio, and pH value were optimized. The optimized method had acceptable limits of detection (LOD) and a precision of 2?µg?L?1 and 8.1% for 4-NP and 0.6?µg?L?1 and 3.7% for 4-t-OP, respectively. The proposed method was successfully applied in river water and effluent from a sewage-treatment plant, and the recoveries spiked at 6?µg?L?1 and 25?µg?L?1 levels were in the range of 82–113%.  相似文献   

4.
A simple and reliable method has been developed for the rapid analysis of trace levels of malachite green from water samples using dispersive liquid–liquid microextraction and high-performance liquid chromatography-diode array detection. Factors relevant to the microextraction efficiency, such as the type and volume of extraction solvent, nature and volume of the disperser solvent, the effect of salt, sample solution temperature and the extraction time were investigated and optimised. Under the optimal conditions the linear dynamic range of malachite green was from 0.2 to 100.0?µg?L?1 with a correlation coefficient of 0.9962. The detection limit and limit of quantification were 0.1?µg?L?1 and 0.3?µg?L?1, respectively. The relative standard deviation (RSD) was less than 2.6% (n?=?5) and the recoveries of malachite green (5.0?µg?L?1) from water samples were in the range of 99.2?±?1.7%. Finally the proposed method was successfully applied for the analysis of malachite green from fish farming water samples.  相似文献   

5.
A simple and efficient method known as dispersive liquid-liquid microextraction (DLLME) was demonstrated for the extraction of triadimefon, uniconazole and tebuconazole in real water samples prior to high performance liquid chromatography-ultraviolet detection (HPLC-UV). Several related parameters that could affect the extraction efficiencies were also investigated and optimised. Under the optimum conditions, a linear range was obtained between the peak area and the concentration of the interested analytes over the concentration range of 1.5–100?µg?L?1 for triadimefon, 2.0–100?µg?L?1 for uniconazole and tebuconazole, respectively. The limits of detection (LODs) (S/N?=?3) values were in the range of 0.9–1.2?µg?L?1. The intra-day and inter-day precisions for the analysis ranged from 2.8 to 7.6%. The relative recoveries of the three analytes in tap, well and lake water samples were in the range of 90.6–105.3%. Finally, a comparison of the sensitivity between the proposed DLLME and the improved single-drop microextraction was also evaluated.  相似文献   

6.
Novel ultrasonically enhanced supramolecular solvent microextraction (USESSM) then high-performance liquid chromatography with ultraviolet detection have been used for extraction and determination of phthalates in water and cosmetics. Coacervates consisting of decanoic acid-based nano-structured aggregates, specifically reverse micelles, have been used the first time as solvents for ultrasound-assisted emulsification microextraction (USAEME). Sonication accelerated mass transfer of the target analytes into the nano-structured solvent from the aqueous sample, thus reducing extraction time. Several conditions affecting extraction efficiency, for example the concentrations of major components of the supramolecular solvent (tetrahydrofuran and decanoic acid), sample solution pH, salt addition, and ultrasonication time, were investigated and optimized. Under the optimum conditions, preconcentration of the analytes ranged from 176 to 412-fold and the linear range was 0.5–100 μg?L?1, with correlation coefficients (R 2)?≥?0.9984. The detection sensitivity of the method was excellent, with limits of detection (LOD, S/N?=?3) in the range 0.10–0.70 μg?L?1 and precision in the range 4.1–11.7 % (RSD, n?=?5). This method was successfully used for analysis of phthalates in water and cosmetics, with good recovery of spiked phthalates (91.0–108.5 %).  相似文献   

7.
A rapid, simple, and efficient method using ultrasound-assisted emulsification microextraction combined with dispersive micro-solid phase extraction (USAE-D-µ-SPE) was developed for detection and quantification of three azole antifungals in milk samples by high-performance liquid chromatography diode array detector. In this study, mesoporous carbon, COU-2, was used as sorbent in USAE-D-µ-SPE for the extraction and preconcentration of analytes. Several important experimental parameters, including type of deproteinized solvents, desorption time, type of extraction solvents, volume of extraction solvent, extraction time, emulsification time, sample pH, salt addition, and mass of COU-2 sorbent, were optimized using spiked milk samples. Under the optimum extraction and detection conditions, three azole antifungals, namely ketoconazole, clotrimazole, and miconazole, were determined within 20 min, with good linearity of matrix-matched calibration in the range of 0.5–5000.0 µg L?1 with coefficient of determination, r 2 ≥ 0.9943. The method showed limits of detection and limits of quantification of all analytes in the range of 0.15–3.0 and 0.5–10.0 µg L?1, respectively. Good repeatability with RSDs <15% (n = 3) and satisfactory relative recoveries (83.3–111.1%) were obtained for spiked azole antifungal drugs in milk. The results reveal that the developed USAE-D-µ-SPE method was a simple, rapid, efficient, environmentally friendly, and practicable method for the determination of azole antifungals in milk samples.  相似文献   

8.
A liquid-phase microextraction (LPME) method was employed for preconcentration of selenium as piazselenol complex in aqueous samples. The samples reacted with o-phenylenediamine in 0.1?M HCl at 90°C for 15?min, and then LPME was performed. A microdrop of carbon tetrachloride was applied as the extracting solvent. After extraction, the microdrop was introduced directly into the injection port of gas chromatography for analysis. Several important extraction parameters such as the type of organic solvent, sample and organic drop volumes, salt concentration, stirring rate, and exposure time were controlled and optimized. In the proposed LPME, the extraction was achieved by suspending a 3?µL carbon tetrachloride drop from the tip of a microsyringe immersed in 12.5?mL of aqueous solution. Under optimized conditions, a dynamic linear range was obtained in the range of 20–1000?µg?L?1. The preconcentration factor and the limit of detection of selenium in this method were 91 and 0.9?µg?L?1, respectively. The optimized procedure was successfully applied to the extraction and determination of selenium in different types of real samples. The relative standard deviations for the spiking levels of 50–100?µg?L?1 in the real samples were in the range of 3.2–6.1%, and the relative errors were located in the range of ?5.4 to 5%.  相似文献   

9.
A new method for the simultaneous determination of 12 volatile organic compounds (trans-1,2-dichloroethene, 1,1,1-trichloroethane, benzene, 1,2-dichloroethane, trichloroethene, toluene, 1,1,2-trichloroethane, tetrachloroethene, ethylbenzene, m-, p-, o-xylene) in water samples by headspace solid phase microextraction (HS–SPME)–gas chromatography mass spectrometry (GC–MS) was described, using a 100?µm PDMS (polydimethylsiloxane) coated fibre. The response surface methodology was used to optimise the effect of the extraction time and temperature, as well as the influence of the salt addition in the extraction process. Optimal conditions were extraction time and temperature of 30?min and ?20°C, respectively, and NaCl concentration of 4?mol?L?1. The detection limits were in the range of 1.1?×?10?3–2.3?µg?L?1 for the 12 volatile organic compounds (VOCs). Global uncertainties were in the range of 4–68%, when concentrations decrease from 250?µg?L?1 down to the limits of quantification. The method proved adequate to detect VOCs in six river samples.  相似文献   

10.
In this paper, a procedure for the determination of 11 aromatic hydrocarbon-type sensitisers and their related compounds from water samples, used in the manufacture of thermal paper, is presented. The compounds were extracted using a solid-phase extraction (SPE) cartridge with an octadecyl (C18) or a phenyl-bonded silica (PH) sorbent and then determined by gas chromatography–mass spectrometry (GC–MS). Factors affecting the performance of the extraction steps were thoroughly evaluated, and their effects on the yield of the sample preparation were discussed. Under optimised experimental conditions, SPE cartridges were conditioned with 10?mL hexane followed subsequently by 10?mL methanol, loaded with water sample at 2?mL?min?1, and eluted with 10?mL hexane at 1.5?mL?min?1. The limits of detection and quantification, calculated for signal-to-noise ratios of 3 and 10, were in the range of 1–5?µg?L–1 and 2.5–10?µg?L–1, respectively. Recovery yields of the present method using river water were in the range of 88%–112% with a C18 sorbent and 86%–116% with a PH sorbent. The repeatability, expressed as a relative standard deviation, was in the range of 2.8%–11% with a C18 sorbent and 0.7%–9.7% with a PH sorbent (n?=?4). Analysis of paper mill effluents revealed the presence of aromatic hydrocarbon-type sensitisers with maximum concentrations of up to 5.2?µg?L?1.  相似文献   

11.
A simple, rapid and efficient method, dispersive liquid–liquid microextraction (DLLME) in conjunction with high-performance liquid chromatography (HPLC), has been developed for the determination of three carbamate pesticides (methomyl, carbofuran and carbaryl) in water samples. In this extraction process, a mixture of 35 µL chlorobenzene (extraction solvent) and 1.0 mL acetonitrile (disperser solvent) was rapidly injected into the 5.0 mL aqueous sample containing the analytes. After centrifuging (5 min at 4000 rpm), the fine droplets of chlorobenzene were sedimented in the bottom of the conical test tube. Sedimented phase (20 µL) was injected into the HPLC for analysis. Some important parameters, such as kind and volume of extraction and disperser solvent, extraction time and salt addition were investigated and optimised. Under the optimum extraction condition, the enrichment factors and extraction recoveries ranged from 148% to 189% and 74.2% to 94.4%, respectively. The methods yielded a linear range in the concentration from 1 to 1000 µg L?1 for carbofuran and carbaryl, 5 to 1000 µg L?1 for methomyl, and the limits of detection were 0.5, 0.9 and 0.1 µg L?1, respectively. The relative standard deviations (RSD) for the extraction of 500 µg L?1 carbamate pesticides were in the range of 1.8–4.6% (n = 6). This method could be successfully applied for the determination of carbamate pesticides in tap water, river water and rain water.  相似文献   

12.
Novel and fast deep eutectic solvent (DES)-based homogeneous liquid–liquid microextraction (HLLME) was applied for the extraction of copper from vegetable samples followed by flame atomic absorption spectrometry (FAAS). 1,5-diphenyl carbazone (DPC) was used as the chelating agent, and a DES was used as the extraction media. The utilized DES was based on benzyl triphenyl phosphonium bromide and ethylene glycol in a 1:8?mole ratio. The phase separation phenomenon was occurred by changing of sample temperature. Several factors influencing the extraction efficiency were investigated and optimized. Under the optimized conditions, an enhancement factor of 64 was obtained. The limit of detection, based on three signal-to-noise ratio, and limit of quantification were found to be 0.13?µg L?1 and 5.0?µg L?1, respectively. The calibration curve was linear within the range of 5.0–250?µg L?1 with r2 > 0.9957. Intra- and inter-day relative standard deviations (%) of 2.1% and 2.6% were obtained at the concentration of 25?µg L?1. The accuracy of the proposed method was evaluated by analyzing a tomato leaves certified reference material and the results were to be in agreement with the certified value. Finally, the feasibility of the method was successfully confirmed by determination of copper in spinach, lettuce, broccoli, potato, carrot and parsley samples.  相似文献   

13.
A method for analysis of 20 commonly used pesticides in surface water based on solid-phase extraction and gas chromatography-mass spectrometry was proposed. During method development the key parameters that can affect SPE extraction and determination such as selection of efficient SPE sorbent, pH of water sample, type and volume of elution solvent, breakthrough volume and matrix effects were investigated. The method was validated using spring water spiked with appropriate concentration of pesticides. The obtained correlation coefficients were in range 0.9972–1.000, limits of detection (LOD) were 0.001–0.5?µg?L?1 and the limits of quantification (LOQ) were 0.005–1?µg?L?1 depending on a pesticide. Much higher LOD (20?µg?L?1) and LOQ (50?µg?L?1) values were obtained for bentazone. The influence of matrix was assessed using real water samples spiked with appropriate concentration of pesticide standards solution. Both signal enhancement and suppression were observed, depending on a pesticide, therefore standard addition method was used for pesticides determination. The developed method was applied on real water samples taken in close vicinity of agricultural fields. Many of the targeted pesticides were found in the samples and the results are presented in this article.  相似文献   

14.
Atrazine and simazine are endocrine-disrupting herbicides that may be transported to surface water, unbalancing ecosystems. Sensitive and low-cost methods are required for monitoring the residues of these compounds. Although several highly sensitive chromatographic methods coupled to tandem mass spectrometry are available, these methods use high-cost instrumentation. Ultraviolet detection usually does not provide the sensitivity and selectivity for monitoring these herbicide residues at the maximum concentrations levels permitted by regulatory agencies, so that extraction and concentration steps are required. Cloud-point extraction in Triton X-114 micelles was investigated to extract and preconcentrate atrazine and simazine. Treatment of 10?mL of sample solutions with 5?mL of 5% (m v?1) Triton X-114 in the presence of NaCl (0.3?g) with heating at 60°C for 30?min led to phase separation and the transfer of herbicides to the surfactant-rich phase, which was dissolved in 90:10 methanol:water for liquid chromatography analysis with ultraviolet detection. The linear dynamic range was 1–50?µg?L?1 for the herbicides. The limits of detection were 0.13 and 0.27?µg?L?1 for simazine and atrazine, respectively. The methodology was applied to water samples fortified with 1, 5, 15, and 50?µg?L?1 of the analytes, resulting in recoveries between 86 and 132% with relative standard deviations less than 6%. The method is low cost and uses small volumes of toxic solvents with useful application in trial studies.  相似文献   

15.
This work reports the application of screen‐printed electrodes bulk‐modified with bismuth precursors to the voltammetric determination of 2‐nitrophenol (2‐NP), 4‐nitrophenol (4‐NP) and 2,4‐dinitrophenol (2,4‐DNP) in water samples. A bismuth film was formed at the electrode surface via in situ reduction of the precursor compound contained in the electrode matrix by cathodic polarization at ?1.20 V. The formation of bismuth layer at the precursor‐modified electrodes was assessed by cyclic voltammetric (CV) at different pH values and by optical techniques. The target nitrophenols were voltammetrically determined by recording their reduction peaks in the differential pulse (DP) mode. The composition and content of the precursor compounds in the printed ink and the effect of the pH of the supporting electrolyte on the DP reduction currents of the 3 target nitrophenols were studied. The limits of quantification (LOQs) in three water matrices (distilled water, tap water and surface water) were in the range 1.1–2.2 µmol L?1. Using a simple solid‐phase extraction (SPE) procedure with Lichrolut EN cartridges and elution with methanol, a preconcentration factor of 100 was achieved; the LOQs were 0.021, 0.027 and 0.025 µmol L?1 for 2‐NP, 4‐NP and 2,4‐DNP, respectively. The recoveries of samples spiked with the 3 target nitrophenols at two concentration levels (0.04 and 0.1 µmol L?1) were always >87 %.  相似文献   

16.
A simple and sensitive method for the extraction of four phthalate esters including dimethyl phthalate (DMP), diethyl phthalate (DEP), benzyl butyl phthalate (BBP) and di-n-butyl phthalate (DBP) as well as their determination in water samples was developed using homogeneous liquid–liquid extraction (HLLE) and HPLC-UV. The extraction method is based on the phase separation phenomenon by the salt addition to the ternary solvent system. The extraction parameters such as type and volume of extracting and consolute solvent, concentration of salt, pH of sample and extraction time were optimized. Under the optimal conditions (extraction solvent: 100?µL CHCl3; consolute solvent: 2.0?mL methanol; NaCl 15% (w/v) and pH of sample: 6.5) extraction recovery was in the range of 92–102%. Linearity was observed in the range of 0.5–300?µg?L?1 for DEP and 0.6–300?µg?L?1 for DMP, BBP and DBP. Correlation coefficients (r 2), limits of detection (LODs) and relative standard deviations (RSDs) were in the ranges of 0.9976–0.9993, 0.18–0.25 and 1.5–4.8%, respectively. The method was successfully applied for the preconcentration and determination of these phthalate esters in the several environmental water samples.  相似文献   

17.
An ultraviolet-photochemical generator (UV-PVG) capable of post-column on-line transformation of both organic and inorganic mercury species to cold vapor (Hg0) with subsequent detection by quartz tube-atomic absorption spectrometry (QT-AAS) was developed. Mercury(II), methylmercury(I), ethylmercury(I), and phenylmercury(I) were successfully detected after separation by reversed-phase high-performance liquid chromatography (RP-HPLC). Two types of AAS detectors were compared. The first was a commonly used line-source instrument while the second was a high-resolution continuum source (HR-CS) AAS. The latter provided better limits of detection: 0.47?µg?L?1 for Hg(II), 0.84?µg?L?1 for methylmercury(I), 0.80?µg?L?1 for ethylmercury(I), and 2.0?µg?L?1 for phenylmercury(I). The repeatability at 30?μg?L?1 was 3.6%, 4.1%, 6.2%, and 4.5% for these species (n?=?10). These figures of merit were comparable with those reported for more sensitive atomic fluorescence spectrometry. Nine sample extraction procedures were investigated. Extraction by tetramethylammonium hydroxide and HCl at 75?°C was selected as the only method compatible with the proposed separation and detection steps providing high extraction efficiency and no changes in mercury speciation. The applicability of the proposed high-performance liquid chromatography–ultraviolet-photochemical vapor generation–quartz tube-atomic absorption spectrometry method was demonstrated using fish samples and certified reference materials (CRM) DOLT-4 (dogfish liver) and ERM-CE464 (tuna fish). The results were comparable to those obtained by a reference method based on L-cysteine extraction and high-performance liquid chromatography–inductively coupled plasma-mass spectrometry (HPLC–ICP-MS) determination.  相似文献   

18.
In this work, surfactant-coated Fe3O4@decanoic acid nanoparticles was synthesized as a viable nanosorbent for coextraction of drugs with different polarities (hydrophobic, hydrophilic). To reach desirable enrichment factors, efficient clean-up and low limits of detection (LODs), the method was combined with dispersive liquid–liquid microextraction (DLLME). The coupling of these extraction methods with GC-FID detection was applied to simultaneous extraction and quantification of venlafaxine (VLF) as a hydrophilic model drug and desipramine (DESI) and clomipramine (CLO) as hydrophobic model drugs in urine samples. The effect of sample pH, nanosorbent amount, sorption time, surfactant concentration, eluent type, eluent volume, salt content, elution time in magnetic solid phase extraction step and extraction solvent and its volume along with sample pH in DLLME step were optimized. Under the selected conditions, linearity was achieved within the range of 5–5000 µg L?1. The LOD values were obtained in the range of 1.5–3.0 µg L?1 for DESI, 1.2–2.5 µg L?1 for VLF and 2.0–4.0 µg L?1 for CLO, respectively. The percent of extraction recoveries and relative standard deviations (n?=?5) were in the range of 82.4–95.9 and 6.1 for DESI, 60.5–92.8 and 6.9 for VLF and 57.2–58.0 and 5.5 for CLO, respectively. Ultimately, the applicability of the new method was successfully confirmed by the extraction and quantification of DESI, VLF and CLO from human urine samples.  相似文献   

19.
In this work, a solidified floating organic drop microextraction was developed based on a vesicular supramolecular solvent consisting of decanoic acid and quaternary ammonium. The method was used for preconcentration of trace amount of cadmium in different rice samples followed by flow-injection analysis–flame atomic absorption spectrometry. Several parameters affecting the extraction efficiency including pH, concentration of 1-(2-pyridylazo)-2-naphthol as the chelating agent, sample and extraction solvent volume, stirring rate, extraction time, salt effect, and interfering ions were investigated and optimized. Under the optimum conditions, a preconcentration factor of 84 was achieved. LOD and LOQ were found to be 0.09 and 0.31 µg L?1, respectively. The calibration curve was linear within the range of 5.0–700 µg L?1 (r2?>?0.9978). Intra- and inter-day precisions (RSD% n?=?3) were estimated 2.7 and 3.9% at the concentration of 20 µg L?1, respectively. The accuracy of the method was successfully validated by analysis of an SRM-1643f standard reference material. Relative recoveries were achieved within the range of 93–107% elucidating suitability of the method for determination of cadmium in rice samples.  相似文献   

20.
The method relies on selective complexation of As(III) with a suitable chelating agent followed by dispersive liquid–liquid microextraction (DLLME) method. Flame atomic absorption spectrometry (FAAS) equipped with microsample introduction system was utilised for determination of As(III). 1-Undecanol and acetone were used as extraction solvent and disperser solvent respectively. Some effective parameters on complex formation and extraction have been optimised. Under the optimum conditions, the enrichment factor of 108 for As(III) was obtained from 9.8?mL of water samples. The calibration graph was linear in the range of 2–15?µg?L?1 with detection limits of 0.60?µg?L?1 for As(III). The relative standard deviation (R.S.D.) for ten replicate measurements of 5.00?µ?gL?1 of As(III) was 6.2%. Operation simplicity and high enrichment factors are the main advantages of DLLME for the determination of As(III) without necessity for hydride generation in water samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号