1.
《Analytical letters》2012,45(9):1430-1441
A new column loaded with modified silica gel-chitosan is proposed as a preconcentration system for adsorption of trace cadmium (II) and copper (II). The optimization steps were performed under dynamic conditions, involving pH, sample flow rate, eluent selection, concentration, volume, and flow rate. Trace Cd(II) and Cu(II) were quantitatively adsorbed by the modified silica gel-chitosan. The metal ions adsorbed on the separation column were eluted with 0.1 M HNO3 and determined by flame atomic absorption spectrometry. Under the optimum conditions, this method allowed the determination of cadmium and copper with limits of detection (LOD) of 20 ng L?1 and 38 ng L?1, respectively. The relative standard deviation values (RSDs) for 1.0 mg L?1 of cadmium and 1.0 mg L?1 of copper were 2.62% and 2.85%, respectively.  相似文献   

2.
We report on the application of emulsification-based dispersive liquid microextraction (EB-DLME) to the preconcentration of Cd(II). This procedure not only possesses all the advantages of routine DLLME, but also results in a more stable cloudy state which is particularly useful when coupling it to FAAS. In EB-DLME, appropriate amounts of the extraction solvent (a solution of dithizone in chloroform) and an aqueous solution of sodium dodecyl sulfate (SDS; acting as a disperser) are injected into the samples. A stable cloudy microemulsion is formed and Cd(II) ion is extracted by chelation. After phase separation, the sedimented phase is subjected to FAAS. Under optimized conditions, the calibration curve for Cd(II) is linear in the range from 0.1 to 25 μg L?1, the limit of detection (at S/N?=?3) is 30 pg L?1, the relative standard deviations for seven replicate analyses (at 0.56 μg L?1 of Cd(II)) is 4.6 %, and the enrichment factor is 151. EB-DLME in our opinion is a simple, efficient and rapid method for the preconcentration of Cd(II) (and most likely of many other ions) prior to FAAS determination.
Figure
Emulsification based dispersive liquid microextraction is presented for determination of cadmium in water samples  相似文献   

3.
A solid‐phase extraction (SPE) method has been presented for the selective separation and preconcentration of trace amounts of cadmium using cetyltrimethylammonium bromide (CTAB)‐coated Fe3O4 nanoparticles (NPs). The method is based on the sorption of cadmium as CdI42? complex on the positively charged surface of the CTAB‐coated Fe3O4 NPs. The preconcentrated cadmium is then desorbed from the surface of the sorbent and is determined by flame atomic absorption spectrometry. The influences of the experimental parameters including pH of the solutions, amount of surfactant, iodide concentration, sample volume, eluent type and volume on the recovery of the analyte ions were investigated. Under the optimum conditions by the extraction of 500 mL of aqueous samples, a preconcentration factor of 250 was achieved. The detection limit (3s) was 0.06 μg L?1, and the relative standard deviations at 0.5 and 5 μg L?1 levels of cadmium (n = 10) were 3.2 and 1.9% respectively. The proposed method was successfully applied to the determination of cadmium in water samples. The accuracy was evaluated through the recovery experiments and independent analysis by the graphite furnace atomic absorption spectrometry (GFAAS).  相似文献   

4.
《Analytical letters》2012,45(11):2285-2295
Abstract

Multi‐walled carbon nanotubes (MWNTs) were used as sorbent for flow injection (FI) on‐line microcolumn preconcentration coupled with flame atomic absorption spectrometry (FAAS) for determination of trace cadmium and copper in environmental and biological samples. Effective preconcentration of trace cadmium and copper was achieved in a pH range of 4.5–6.5 and 5.0–7.5, respectively. The retained cadmium and copper were efficiently eluted with 0.5 mol L?1 HCl for on‐line FAAS determination. The MWNTs packed microcolumn exhibited fairly fast kinetics for the adsorption of cadmium and copper, permitting the use of high sample flow rates up to at least 7.8 mL min?1 for the FI on‐line microcolumn preconcentration system without loss of the retention efficiency. With a preconcentration time of 60 sec at a sample loading flow rate of 4.3 mL min?1, the enhancement factor was 24 for cadmium and 25 for copper at a sample throughput of 45 h?1. The detection limits (3σ) were 0.30 and 0.11 µg L?1 for Cd and Cu, respectively. The precision (RSD) for 11 replicate measurements was 2.1% at the 10‐µg L?1 Cd level and 2.4% at the 10‐µg L?1 Cu level. The developed method was successfully applied to the determination of trace Cd and Cu in a variety of environmental and biological samples.  相似文献   

5.
Polystyrene (PS) was extracted from styrofoam waste and functionalised with schiff base, N,N-bis(salicylidene)cyclohexanediamine (SCHD) through an azo spacer. The resin was characterised and used for preconcentration of Pb(II), Ni(II) and Cd(II) ions prior to their trace determinations by microsample injection system–coupled flame atomic absorption spectrometry (MIS-FAAS). The recoveries of studied metal ions were achieved ≥96.0% with relative standard deviation (RSD) ≤4.5 at optimum parameters: pH 8; resin amount 300 mg; flow rates 3.0 mL min?1 of sample solution; and 2.0 mL min?1 of eluent (2.0 mol L?1 HNO3). The limits of detection (LODs) and limits of quantification (LOQs) were found to be 0.32, 0.23 and 0.21 and 1.10, 0.78 and 0.69 μg L?1, respectively, with preconcentration factors (PFs) of 500, 800 and 1000, respectively. The linear ranges of the method were 1–40, 1–25 and 1–20 μg L?1 for Pb(II), Ni(II) and Cd(II) ions, respectively. The accuracy and validation of the method were evaluated by analysis of certified reference materials (CRMs). The method was successfully applied for preconcentration of studied metal ions in wastewater and wastewater-irrigated vegetable samples.  相似文献   

6.
The present article reports the application of Thiosemicarbazide‐modified multiwalled carbon nanotubes (MWCNTs‐TSC) as a new, easily prepared selective and stable solid sorbent for the preconcentration of trace Co(II), Cd(II), Cu(II) and Zn(II) ions in aqueous solution prior to the determination by flame atomic absorption spectrometry. The studied metal ions can be adsorbed quantitatively on MMWNTs at pH 5.0 and then eluted completely with HNO3 (1.5 mol L?1) prior to their determination by flame atomic absorption spectrometry. The separation/preconcentration conditions of analytes were investigated, including the pH, the sample flow rate and volume, the elution condition and the interfering ions. The maximum adsorption capacity of the adsorbent at optimum conditions were found to be 32.5, 27.3, 44.5 and 34.1 mg g?1 for Co(II), Cd(II), Cu(II) and Zn(II), and the detection limits of the method were found to be 0.28, 0.13, 0.21 and 0.17 μg L?1, respectively. The proposed method was successfully applied for extraction and determination of the analytes in well water, sea water, wastewater, soil, and blood samples.  相似文献   

7.
A sensitive and simple method has been established for simultaneous preconcentration of trace amounts of Pb (II) and Ni (II) ions in water samples prior to their determination by flame atomic absorption spectrometry. This method was based on the using of a micro-column filled with graphene oxide as an adsorbent. The influences of various analytical parameters such as solution pH, adsorbent amount, eluent type and volume, flow rates of sample and eluent, and matrix ions on the recoveries of the metal ions were investigated. Using the optimum conditions, the calibration graphs were linear in the range of 7–260 and 5–85 μg L?1 with detection limits (3Sb) of 2.1 and 1.4 μg L?1 for lead and nickel ions, respectively. The relative standard deviation for 10 replicate determinations of 50 μg L?1 of lead and nickel ions were 4.1% and 3.8%, respectively. The preconcentration factors were 102.5 and 95 for lead and nickel ions, respectively. The adsorption capacity of the adsorbent was also determined. The method was successfully applied to determine the trace amounts of Pb (II) and Ni (II) ions in real water samples. The validation of the method was also performed by the standard reference material.  相似文献   

8.
《Analytical letters》2012,45(2):322-342
Abstract

The isolation, identification and characterization of bacteria obtained from soil of Ergani Makam Mountain were performed and the results revealed that the bacteria were thermophilic Anoxybacillus caldiproteolyticus. The characterized bacteria and purchased Geobacillus stearothermophilus were immobilized on Amberlite XAD-16 in order to prepare two biosorbents for preconcentration experiments for the determination of cadmium (II) ions. The produced biosorbents were enriched separately using mini-columns and the analyte was determined by flame atomic absorption spectrometry. The effects of solution parameters were investigated for the separation and preconcentration yields. The recovery efficiencies of Amberlite XAD-16 immobilized separately with A. caldiproteolyticus and G. stearothermophilus were determined to be 98.23?±?2.40 and 98.93?±?1.3 (n?=?5) for the optimum working conditions, respectively. Moreover, the Cd (II) ion was recovered with 10?mL of 1?mol L?1 of HCl and 2?mL of 0.5?mol L?1 HNO3 solutions. The optimum working conditions were determined to be at pH 6.0 and a flow rate of 2?mL min?1 for both biosorbents. The recovery efficiencies of matrix ions were characterized to investigate the feasibility of the developed preconcentration methods. The accuracy of the proposed methods were controlled by analyzing a SCP Science EnviroMAT Waste Water, Low (EU-L-2) certified reference material. The obtained results were comparable to the certified values. These methods were also applied to the analysis of water samples from Dicle River, Hazar Lake and Diyarbak?r tap water for Cd (II).  相似文献   

9.
《Analytical letters》2012,45(12):1978-1990
A novel absorbent was prepared by sodium dodecyl sulfonate (SDS)-modified activated carbon (SDS-AC) and was employed as the microcolumn packing material for separation/preconcentration of trace Cd(II). The method based on Cd(II) was quantitatively retained by SDS-AC sorbent, which entailed cation exchange nature and negative charged surface, facilitating favorable retention of positively charged ions. The retained Cd(II) was effectively recovered with elution by 1 mol · L?1 HNO3, and the eluent was quantified by electrothermal atomic absorption spectrometry (ET-AAS). Under the optimized conditions, the limit of detection (LOD) for Cd(II) was 3 ng · L?1 with the consumption of 20.0 mL sample solution. The relative standard deviation (RSD) for ten replicate measurements of 50 ng · L?1 Cd(II) was 2.9%. The developed technique was demonstrated for the determination of trace Cd(II) in water samples and the recoveries for spiked samples were found to be in the range of 94.9–107.2%. For validation, two certified reference materials of water samples (GBW08607 and GBW08608) were analyzed, and the results obtained were in good agreement with the certified values.  相似文献   

10.
Attapulgite modified with 2-hydroxy-1-naphthaldehyde was prepared and applied to the separation, preconcentration and determination of Cu(II) in aqueous solutions by inductively coupled plasma optical emission spectrometry. Experimental conditions for effective adsorption of trace levels of Cu(II) were optimized using batch and column procedures. The optimum pH value for the separation of Cu(II) on the newly sorbent was 4.0 and complete elution of Cu(II) from the sorbent surface was carried out using 2 mL of 0.01 mol L?1 HCl. The adsorption capacity for Cu(II) was 25.13 mg g?1. The detection limits of the method defined by IUPAC were found to be 0.24 μg L?1 with enrichment factor of 150. The method has been applied to the determination of Cu(II) in certified reference materials and natural water samples with satisfactory results.  相似文献   

11.
A solid phase extraction method is established for preconcentration of nickel, lead, cadmium, copper and cobalt using pipette tip solid phase extraction. The presented process was dependent on chelation of analytes with 1,3,4-thiadiazole-2,5-dithiol, then allowing the solution to flow through an activated carbon cloth packed pipette tip. The adsorbed metal chelates on the surface of activated carbon cloth were eluted by 5 mL of 3 M HNO3. The concentrations of nickel, lead, cadmium, copper and cobalt were detected using a flame atomic absorption spectrometer (FAAS). The pipette tip solid phase extraction exhibit a preconcentration factor of 120. The limit of detection values were 2.7, 1.7, 1.3, 2.0 and 2.9 µg L?1 for Ni(II), Pb(II), Cd(II), Cu(II) and Co(II), respectively. Validation of the method was checked by the analysis of TMDA-53.3 and TMDA-64.2 certified reference materials. The method was successfully applied for water and fertiliser samples.  相似文献   

12.
We report on the separation and preconcentration of lead(II) and copper(II) ions using silver-coated titanium dioxide nanoparticles modified with cysteamine, and their determination by slurry analysis via flame atomic absorption spectrometry. The ions were adsorbed via a conventional batch technique, and the ion-loaded slurry was separated and directly introduced into the spectrometer, thereby eliminating a number of drawbacks. The effects of pH, amount of sorbent, slurry volume, sample volume and other ions on the recovery were investigated. Under optimized experimental conditions, copper and lead can be recovered within the 95% confidence level in certificated waste water, but also in spiked sea water samples. The technique is fast, simple, and leads to complete elution. The limit of detection (3δ, at n?=?10) was 0.37 μg L?1 for Cu(II), and 0.38 μg L?1 for Pb(II).
Figure
We report on the separation and preconcentration of lead(II) and copper(II) ions using silver-coated titanium dioxide nanoparticles modified with cysteamine (Fig. 1), and their determination by slurry analysis via flame atomic absorption spectrometry. Under optimized experimental conditions, copper and lead can be recovered within the 95% confidence level in certificated waste water and spiked sea water samples. The technique is fast, simple, and leads to complete elution. Figure 1. Schematic illustration of the preparation of TiO2@Ag–Cysteamine nanoparticles and inset shows the color of the nanoparticles.  相似文献   

13.
A highly selective thiol-functionalized ionic liquid (thiol-FIL) was synthesized and characterized by FT-IR and ESI mass spectroscopy. The capability of thiol-FIL to extract Cd(II), Ni(II), Cr(III) and Pb(II) was evaluated. It is found that thiol-FIL possesses high selectivity for Cd(II), and this has led to a method for determination of Cd(II) by flame atomic absorption spectrometry that is free of interferences by up to a 1,000-fold excess of Na(I), Mg(II), Ca(II), Mn(II), Fe(III), Al(III), Cu(II), Zn(II), Ni(II), Cr(III), Co(II), As(III), Pb(II), and Hg(II). With extraction equilibrium time of 1 min, a good linearity (r = 0.9998) and a detection limit of 0.39 μg?L?1 were obtained. The precision (RSD) for 11 replicate measurements of 10 μg?L?1 Cd was 1.6%. The method was validated using certified reference materials. The recoveries of cadmium in spiked real samples ranged from 97% to 102%.  相似文献   

14.
Cadmium and nickel ions have been preconcentrated on Geobacillus thermoleovorans subsp. stromboliensis, immobilized on Amberlite XAD-4, and were determined by flame atomic absorption spectrometry (FAAS). Parameters such as pH, amount of adsorbent, eluent type and volume, flow rate of solution and the matrix interference effect on retention have been studied, and extraction conditions were optimized. Elution of Cd(II) and Ni(II) from minicolumns was carried out with 1.0 M hydrochloric acid or nitric acid with recoveries from 97 to 100%. The sorption capacity is 0.0373 and 0.0557 mmol g?1 for Cd(II) and Ni(II), respectively. The detection limits were 0.24 μg L?1 for cadmium and 0.3 μg L?1 for nickel. The relative standard deviations of the procedure were below 10%. The procedure was validated by analyzing certified reference materials and applied to the determination of Cd(II) and Ni(II) in natural water and food samples.  相似文献   

15.
Cloud point extraction (CPE) has been used for the preconcentration and indirect quantification of cyanide after the formation of a ion-associate complex with 3-amino-7-diethylamino-8,9-benzo-2-phenoxazine chloride (Nile blue, NB+) in the presence of copper (II) ions, and later analysis by flame atomic absorption spectrometry (FAAS) using polyethyleneglycolmono-p-nonylphenylether (PONPE 7.5) as extracting surfactant. The chemical variables affecting the separation phase and the viscosity affecting the detection process were optimized. At pH 5.5, preconcentration of only 50 mL of sample in the presence of 0.04 % (w/v) PONPE 7.5 and 5.64 × 10?5 mol L?1 Nile blue permitted the detection of 3.75 μg L?1 cyanide. The enhancement factor was 64.7 for cyanide. The proposed method was successfully applied to the determination of free cyanide in environmental water samples. The method was compared with the pyridine–barbituric acid method and the paired t test was used to determine whether the results obtained by the two methods differ significantly.  相似文献   

16.
We report on a novel method for on-line cloud point extraction (CPE) for preconcentration of cadmium ions. It is based on electromagnetic induction-assisted heating (EMIH) of iron particles in a packed bed contained in a quartz tube that acts as an on-line CPE enrichment column. The cadmium complex of 1-(2-pyridylazo)-2-naphthol is quantitatively retained by the column under the cloud point temperature with the help of EMIH. The column was then eluted with alcoholic borax buffer at room temperature and on-line coupled to FAAS. Under optimum conditions, the limit of detection (3 sb/b) and limit of quantification (10 sb/b) are 0.21 μg?L?1 and 0.70 μg?L?1 of Cd(II), respectively, and the relative standard deviation is 3.8 % (for n?=?8; at 20 ng?mL?1). An enhancement factor of 76 is typically achieved. The correlation coefficient of the calibration graph using the present method was 0.9986. The method was successfully applied to determine Cd(II) in water samples
Figure
An on-line cloud point extraction method was developed. Iron particles packed bed acts as an enrichment column. The cadmium complex of 1-(2-pyridylazo)-2-naphthol is quantitatively retained by the column under the cloud point temperature with the help of electromagnetic induction-assisted heating technique  相似文献   

17.
In this study, we demonstrated a highly sensitive electrochemical sensor for the simultaneous detection of Pb (II) and Cd (II) in aqueous solution using carbon paste electrode modified with Eichhornia crassipes powder by square wave anodic stripping voltammetry. The effect of modifier composition, pH, preconcentration time, reduction potential and time, and type of supporting electrolyte on the determination of metal ions were investigated. Pre-concentration on the modified surface was performed at open circuit. The modified electrode exhibited well-defined and separate stripping peaks for Pb (II) and Cd (II). Under optimum experimental conditions, a linear range for both metal ions was from 10 to 5000 μg L?1 with the detection limits of 4.9 μg L?1, 2.1 μg L?1 for Cd(II) and Pb (II), respectively. The modified electrode was found to be sensitive and selective when applied to determine trace amounts of Cd (II) and Pb (II) in natural water samples.  相似文献   

18.
The sorption behaviour of Cd(II) on three carbon-based materials including activated carbon (AC), carbon nanotubes (CNTs) and carbon-encapsulated magnetic nanoparticles (CEMNPs) which were prepared under similar conditions by nitric acid treatment were investigated. Generally, sorption of cadmium on these materials increased with the increase of pH. For AC and CNTs very similar results were obtained, while CEMNPs exhibits much higher affinity for Cd(II) despite of almost the same surface acidity. Thus, cadmium retention on tested sorbents was more dependent on the concentration of specific active sites than the total surface area available. The equilibrium sorption data were better fitted to Langmuir isotherm. The theoretical saturation capacity of the monolayer derived from this model at pH 8.0 for AC, CNTs and CEMNPs are 9.91 mg g?1, 20.37 mg g?1 and 91.0 mg g?1, respectively. The kinetic of Cd(II) sorption is fitted for pseudo-second order equation and could be described as a combination of film diffusion and intra-particle diffusion, whereby the last one dominates. The experimental parameters for preconcentration of cadmium on a microcolumn packed with CEMNPs prior to its determination by flame atomic absorption spectrometry have been investigated. Cadmium can be quantitatively retained at pH 8 from sample volumes up to 150 mL and then eluted completely with 3 mL of 0.5 mol L?1 HNO3.  相似文献   

19.
A novel adsorbent of multi-wall carbon nanotubes (MWCNTs) chemically modified silica (MWCNTs-silica) was synthesised and employed as the adsorbent material for solid-phase extraction (SPE) of trace Zn(II), Cu(II), Cd(II), Cr(III), V(V) and As(V) in environmental water samples followed by inductively coupled plasma optical emission spectrometry detection. This material inherits the advantages of nanomaterial MWCNTs and conventional silica with dual functional groups (–NH2 and –COOH), and avoid the problem of nanomaterial in SPE, such as high pressure. The factors affecting the separation and preconcentration of target elements such as pH, sample flow rate and volume, eluent concentration and volume were investigated. Under the optimised conditions, the detection limits for Zn(II), Cu(II), Cd(II), Cr(III), V(V) and As(V) were 0.27, 0.11, 0.45, 0.91, 0.55 and 0.67 μg L?1 with the relative standard deviations of 3.1, 5.9, 4.1, 4.0, 7.3 and 8.6% (c = 10 μg L?1, n = 7), respectively. The adsorption capacity of MWCNTs-silica was 26.6, 70.0, 13.8, 58.0, 20.0 and 20.0 mg g?1 for Zn(II), Cu(II), Cd(II), Cr(III), V(V) and As(V), respectively, and the prepared adsorbent could be reused more than 100 times. In order to validate the developed method, two certified reference materials of GSBZ50009-88 and GSBZ 50029-94 environmental waters were analysed and the determined values were in good agreement with the certified values. The developed method has been applied to the determination of trace elements in environmental water samples with satisfactory results.  相似文献   

20.
A new sorbent – salen impregnated silica gel – was prepared and characterised for application as a minicolumn packing for flow-injection on-line preconcentration of cadmium(II). The system was coupled with flame atomic absorption spectrometer (FI-FAAS). The optimal pH for Cd(II) sorption was in the range of 7.4–8.8 and nitric acid (1%, v/v) was efficient as eluent. Sorption was most effective within the sample flow rate up to 7?mL?min?1. Sorption capacity of the sorbent found in a batch procedure was 26.3?µmol?g?1 (2.95?mg?g?1). Enrichment factor (EF) and limit of detection (LOD) obtained for 120-second loading time were 113 and 0.26?µg?L?1, respectively. The sorbent stability in the working conditions was proved for at least 100 preconcentration cycles. The evaluated method was applied to Cd(II) determination in various water samples.  相似文献   