首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
In order to increase chromatographic selectivity and to extend the analytical capability of reversed phase liquid chromatography (RP HPLC) many investigators have concentrated on the preparation of silica based column packings with chemically bonded phases (CBP). These phases have also been successfully used in sample preparation techniques, mainly in solid phase extraction (SPE). Although alkyl bonded phases (e.g., C2, C8, and C18) are the most widely used packings in RP HPLC and SPE, various specific applications require CBPs with polar functional groups (e.g., -NH2, -NO2, -CN, and/or -OH). The solution of problems with separation of complicated chiral compounds was attempted by applying stationary phases with chiral selectors (e.g., cyclodextrins, Pirkle phases, crown ethers, etc.). On the other hand, packings with pseudo-membrane or liquid crystal properties have been utilized for the separation of various substances of natural origin. Porous silica is commonly used as a support in the preparation of CBPs. Its physico-chemical characteristics, such as: type and structure of siliceous matrix, porosity, type and concentration of silanol groups, as well as surface purity, strongly influence the density and structure of chemically bonded phases. Recognition of these properties is helpful in optimizing separation processes based on RP HPLC elution and/or extraction of substances with polar character.  相似文献   

2.
A comparison of SPE cartridges produced in authors laboratory containing silica modified by addition of three functional moieties with standard C-18 and SDVB cartridges was made in terms of their applicability for the isolation of flavor compounds. Compounds found in wine and grapes were used for model mixture, which was spiked into a grape juice. Functionalized phases for SPE were prepared modifying silica gel with alkoxysilanes with different functional groups: (3-(phenylamino)-propyltrimethoxysilane, octyltriethoxysilane and octadecyl-silane. The functionalization was carried out by the dry method, which resulted 5, 10 and 20 weight parts of initial support. Functionalized phases were characterized using FT-IR, elemental analysis and NMR.Performance for new phases compared to “standard” ones (C-18 and SDVB (styrene–divinylbenzene) varied, depending on the group or type of analyzed compound. They were more efficient in extraction of methyl anthranilate and vanilins. For extraction of terpenes, C-6 alcohols, isoprenoids, benzene derivatives and phenols their efficiency was comparable to that of C-18.Functionalized laboratory-made mixed phases are suitable for extraction of flavor compounds from grape juice. They are suitable for extraction of compounds belonging to different chemical classes with the efficiency comparable to C-18 and SDVB phases. The production of such functionalized phases can be easily performed in the laboratory, at a very low cost, comparing to C-18 or SDVB cartridges. This makes the proposed functionalized phases an interesting alternative, in sample preparation for analysis and particularly in preparative/flash chromatography.  相似文献   

3.
Abstract

A new technique for the extraction of anthracyclines and their metabolites from plasma or serum is described, which gives suitable extracts for HPLC analysis of these drugs in patients. This technique consists in a very rapid chromatographic step on the bonded silica contained in small open columns (C-18 Sep-Paks, Waters Associates). This extraction gives quantitative recoveries of all the anthracyclines and metabolites that have been tested; 0.2 to 3 ml of plasma can be processed, with concentrations up to 5,000 ng/ml. The advantages of this technique over classical techniques using an organic extraction with a partition between two phases are: speed, simplicity, efficacy, reproducibility and similarity of recoveries for various anthracyclines.  相似文献   

4.
《Analytical letters》2012,45(15):3083-3110
ABSTRACT

A solid phase extraction (SPE) system has been modified with cationic surfactants and evaluated for extraction and preconcentration of trace phenolic compounds contaminants in water at low ppb concentrations. Cationic surfactants such as cetyl trimethyl ammonium bromide (CTAB) has been steadily adsorbed on the surface of C-18 bonded silica, and the ionized functional group of the surfactant can then act as an ion–exchange site to attract the ionized phenolic compounds from water samples. The method includes enrichment of the phenolic compounds by the surfactant-loaded solid phase extraction system, followed by elution of the analyte with methylene chloride and derivatization of the phenolic compounds with acetic anhydride. Thirty-two phenolic analytes were identified and quantitatively determined by this method; identification and quantification of the compounds is performed with GC/FID using 2-bromophenol as internal standard. SPME analysis with this method was linear over 3-6 orders of magnitude, with linear correlation coefficient (R2) greater than 0.96. Experimentally determined FID detection limits ranged from ~30 ppt for methyl-substituted phenols to ~0.1ppb for phenol and chloro-substituted phenols. We tested the influence of sample pH, the loading amount of surfactant on the solid phase, and the volume and matrixes of the sample were studied. Absolute recoveries from pure water spiked with 0.2 ppb phenolic compounds were 96 – 103%. The method has been applied to analysis of various natural waters, including ground water, lake water, seawater, and wastewater. Recoveries from ground water, lake water, seawater, and wastewater were 92 – 106%, 75 – 93%, 87 – 103%, 86 – 99%, respectively. Therefore, the new technique proved to be an excellent tool for trace enrichments of phenolic compounds at low ppb concentration of these analytes, from different natural water samples.  相似文献   

5.
A method for the determination of trace levels of triazines and organophosphorus pesticides in water is presented. The extraction method is based on a solid-phase extraction on C-18 bound silica SPE cartridges. A precolumn filled with Merck C-18 bound silica and home-made C-18 bound silica have been tested at a flow-rate of 3 ml/min with comparable preconcentration yields. A SIM-MS method using a 15N labelled internal standard has been developed for the organophosphorus pesticides. Detection limits lower than 1 g/L have been obtained. Separations have been carried out on a conventional GC column OV 17 (1 m) and a capillary column OV 17 (25 m) with a temperature program from 150° C (2 min) to 300° C (rate of 6° C/min).  相似文献   

6.
The chiral liquid chromatographic separation of two pyrethroid insecticides, tau-fluvalinate and permethrin, on different polysaccharide-based chiral stationary phases (CSPs) has been investigated. Complete separation of these compounds was achieved with Chiralcel OJ under normal phase mode and a mobile phase of n-hexane:ethanol (90:10, v/v). This method has been used for determining these compounds in drinking water at ppb levels after solid-phase extraction (SPE) with C-18 cartridges. Recoveries ranged between 103–113% and precision values (expressed as relative standard deviations) were lower than 10%.  相似文献   

7.
A method for the determination of trace levels of triazines and organophosphorus pesticides in water is presented. The extraction method is based on a solid-phase extraction on C-18 bound silica SPE cartridges. A precolumn filled with Merck C-18 bound silica and home-made C-18 bound silica have been tested at a flow-rate of 3 ml/min with comparable preconcentration yields. A SIM-MS method using a (15)N labelled internal standard has been developed for the organophosphorus pesticides. Detection limits lower than 1 microg/L have been obtained. Separations have been carried out on a conventional GC column OV 17 (1 m) and a capillary column OV 17 (25 m) with a temperature program from 150 degrees C (2 min) to 300 degrees C (rate of 6 degrees C/min).  相似文献   

8.
A procedure based on solid-phase extraction (SPE) followed by high-performance liquid chromatography (HPLC) with diode array detection has been developed for the simultaneous analysis of 16 widely used pesticides in groundwater samples. The compounds analysed were: aldicarb, atrazine, desethylatrazine, desysopropylatrazine, carbofuran, 2,4-D, dicloran, fenitrothion, iprodione, linuron, metalaxyl, metazachlor, phenmedipham, procymidone, simazine and vinclozolin. Five different SPE sorbents, C18 bonded silica (Isolute SPE C18 (EC)), graphitised carbon black (Superclean Envi-Carb), highly cross-linked polystyrene-divinylbenzene (Lichrolut EN), divinylbenzene-N-vinylpyrrolidone (Oasis HLB) and surface modified styrene-divinylbenzene (Strata X), were compared. HPLC separation and quantification of the selected pesticides was carried out under isocratic conditions by means of a new reversed-phase column (Gemini from Phenomenex) based on C18 bonded to organic-silica particles. Oasis HLB and Strata X provided the best results in the preconcentration of 1-l samples, yielding average recoveries higher than 70%, except for phenmedipham that rapidly degrades in groundwater. Detection limits of the target pesticides provided by the proposed SPE-HPLC procedure were between 0.003 and 0.04 μg l−1.  相似文献   

9.
Abstract

A specific, sensitive, qualitative and quantitative extraction procedure followed by an high pressure liquid chromatography equipped with electrochemical detector assay of catecholamines (CATs) and their metabolites from human urine has been developed. Using an unique multiple interaction bonded silica gel disposable solid phase extraction (SPE) column, various analytes were selectively isolated from the urine components. After following three different extraction procedures, the presence of free CATs (epinephrine, norepinephrine and dopamine) and their basic (normetanephrine, metanephrine, and 3-methoxydopamine) and acidic (vanillylmandelic acid, homovanillic acid and 5-hydroxyindoleacetic acid) metabolites was confirmed and quantitated by electrochemical detector.  相似文献   

10.
《Analytical letters》2012,45(10):1811-1817
Abstract

A novel estazolam-imprinted silica sorbent was prepared by the surface imprinting technique using 3-aminopropyltriethoxysilane (APTEOS) and phenyltrimethoxysilane (PTMOS) as functional monomers. The functional monomers are expected to form hydrogen bonds and π-π interactions with estazolam. The imprinted silica sorbent was characterized by Fourier transform infrared spectroscopy (FT-IR), element analysis, and scanning electron micrograph (SEM). Compared to C18 solid phase extraction (SPE) and liquid-liquid extraction, molecular imprinting polymer (MIP) SPE was the most feasible method to extract estazolam from human plasma, and the recovery of estazolam was up to 98.7±1.2%.  相似文献   

11.
Abstract

Monochlorosilanes have been prepared with yields of about 80% through a catalytic hydrosilylation of terminal olefins. Subsequently, the silanes are chemically bonded to silica to obtain: (i) n-octyldimethylsilyl bonded phases with reproducible surface coverage ranging from 0.8 to 3.5 μmol/m2, (ii) propyldimethylsilyl bonded phases with different functional groups at the γ-position, all showing a nearly equal surface coverage of some 3.3 μmol/m2, and (iii) n-alkyldimethylsilyl bonded phases with chainlengths ranging from 1 to 22 carbon atoms and with surface coverages ranging from 3.9 μmol/m2 for RP-1 to 3.0 μmol/m2 for the RP-22 bonded phase. A simplified model based on the pore structure of silica allows an explanation and estimation of the maximum surface coverage as a function of the chainlength of the bonded phase.  相似文献   

12.
The objective of this paper is to provide information about solid phase extraction (SPE) as an alternative to liquid-liquid extraction of amines from several matrices. Different sorbents ranging from non-polar phases, such as C18 silica to more polar such as cyanopropylsilica (CN) have been tested for analysis of aliphatic amines as monoamines, diamines and polyamines. Phenylalkylamines such as amphetamine or methamphetamine and heterocyclic amines such as histamine or cephalosporins (which also contain a carboxylic group), have also been studied. The different steps involved in the extraction procedure have been tested (conditioning, retention, pre-concentration, washing and elution) in order to obtain extracts free of interferences and enough sensitivity. C18 silica (100 mg) was selected as optimal phase with recoveries nearly of 100%. The elution of more polar amines was performed in acidic conditions while less polar amines required organic solvents. Cephalosporin retention was performed in acid condition by using disk cartridges EM C18, which gave better selectivity. The optimised clean-up procedures have been discussed to the quantification of the corresponding amines in real samples (urine, water and beer). The accuracy and precision were outlined.  相似文献   

13.
14.
《Analytical letters》2012,45(13):2793-2804
ABSTRACT

Aqueous extracts of plant-derived smoke (smoky water) are a complex mixture of thousands of components. Solid phase extraction (SPE) cartridges of varying polarity were trialed for their effectiveness in cleaning up smoky water, prior to subsequent analysis. The most effective SPE cartridge used was normal phase silica bonded with aminopropyl (NH2) with hexane/dichloromethane/methanol mixtures as eluting solvents. This system retained all the active components and permitted elution of two active fractions, separated by an inactive fraction. Other cartridges tested either did not retain all active components or eluted active fractions successively, with more overlap between compositions. Active fractions, as identified by germination tests, were examined by GC-MS and were found to be sufficiently simplified to allow the identification of a new germination cue, 1, 8-cineole.  相似文献   

15.
Abstract

A sensitive, specific, qualitative, and quantitative extraction procedure followed by an hplc assay of 11-nor-Δ-9-tetrahydrocannabinol-9-carboxylic acid (THC-COOH) from human urine is developed. Using a new, “mixed mode”, bonded silica gel solid phase extraction (SPE) column, the analyte was selectively isolated from the urine component. Following extraction, the presence of THC-COOH was confirmed and quantitated by a UV detector on a Varian 15cm C18 column using 35:65 v/v 50 mM phosphoric acid:acetonitrile at a flow rate of 1.5 mL/min. The limit of detection was 10 ng/mL at a signal to noise ratio of 2.5. The method showed linearity in the 10–300 ng/mL range (r=0.999) with good precision (RSD 1.4%) and accuracy (87% absolute recovery).  相似文献   

16.
Abstract

Chloroform extraction of Co-PAR, Fe-PAR, and Cu-PAR complexes in a pH 6.5 phosphate buffer implied the first two species were primarily monoanions, but the latter was a dianion. Examination of the literature and retention data of these complexes on C-18 and amino columns confirmed the more anionic nature of Cu-PAR. The Co+3 and Cu+2 complexes were slightly resolved from each other, but the Fe+3 complex was retained longer on the C-18 silica. In contrast, the Co+3 and Fe+3 complexes were not resolved, but the Cu+2 complex was well-retained on the weak anion exchange amino silica column. Use of short amino and C-18 columns in series provided a good separation of all three complexes. Detection of the metal complexes at 546 nm instead of 254 nm avoided interference by PAR and good detection limits were still maintained.  相似文献   

17.
Summary A fully integrated chromatographic system was developed for the determination of leukotrienes in biological samples using photodiode-array detection (PDAD), which eliminates time consuming manual sample handling steps. A special solid phase extraction, (SPE) methodology for leucotriene metabolite stability was developed which increased the recoveries and eliminates the contamination risk of biological samples. The inherent instability (autooxidation) of many of the leukotriene mediators, and the adsorption effects onto exposed surfaces in vials and in the chromatographic system were found to be very important parameters to control in order to circumvent high loss of sample analytes. By binding the cell supernatants to the functionalities of the SPE support stabilised these mediators. Cell culture samples were eluted through a disposable C18 SPE column. The SPE columns were allowed to thaw and deposited in an automated sample handling unit (ASPEC XL). Desorption of the analytes was followed by a second on-line SPE step, to eliminate remaining interfering matrix compounds. Typical recoveries when stored at −70°C were in-between 55–97% except for (LTE4) which was found to be around 40% after 72 days of storage. Seven reversed-phase packings were studied. Selectivity factors, as well as the separation efficiencies, were found to differ for the various C18 bonded silica stationary phases. This integrated on-line column liquid chromatographic system was applied to the determination of leukotriene B4, leukotriene C4, leukotriene D4, leukotriene and E4 in human cell extracts using prostaglandin B2 as the internal standard. More than 1500 biological samples were analysed. Some validation data are presented for unattended operations.  相似文献   

18.
A simple solid-phase extraction (SPE) procedure with an octadecyl bonded phase silica (C18) was developed for clean-up of the fungicide thiram from aqueous solutions containing high concentrations of humic substances, for future studies of thiram adsorption onto solid humic substances or soils. Suspensions of humic acids and soil, in aqueous 0.01 M CaCl2 solution, were prepared and used as samples. These extracts were spiked with thiram and immediately applied to a C18-SPE cartridge. Thiram was eluted with chloroform and its concentration measured by spectrophotometry at 283 nm. Non-spiked aqueous extracts (blanks) and a control sample of thiram in 0.01 M CaCl2 aqueous solution were also prepared and submitted to the same SPE procedure. The results show that humic substances are extensively retained by the C18 cartridge but are not eluted with CHCl3. Recoveries of 100-104% were obtained for thiram in the presence of humic substances. The SPE procedure described in this work is an efficient clean-up step to remove the interference of humic substances absorbance and to be coupled to any spectrophotometric or HPLC-UV method, usually used for thiram analysis in food extracts.  相似文献   

19.
Two novel types of crown ether capped β‐cyclodextrin (β‐CD) bonded silica, namely, 4′‐aminobenzo‐X‐crown‐Y (X=15, 18 and Y=5, 6, resp.) capped [3‐(2‐O‐β‐cyclodextrin)‐2‐hydroxypropoxy] propylsilyl‐appended silica, have been prepared and used as stationary phases in capillary electrochromatography (CEC) to separate chiral compounds. The two stationary phases have a chiral selector with two recognition sites: crown ether and β‐CD. They exhibit excellent enantioselectivity in CEC for a wide range of compounds. After inclusion of metal ions (Na+ or K+) from the running buffer into the crown ether units, the stationary phases become positively charged and can provide extra electrostatic interaction with ionizable solutes and enhance the dipolar interaction with polar neutral solutes. This enhances the host‐guest interaction with the solute and improves chiral recognition and enantioselectivity. Due to the cooperation of the anchored β‐CD and the crown ether, this kind of crown ether capped β‐CD bonded phase shows better enantioselectivity than either β‐CD‐ or crown ether bonded phases only. These new types of stationary phases have good potential for fast chiral separation with CEC.  相似文献   

20.
Wuliangye baijiu is one of the most famous baijiu in China, with a rich, harmonic aroma profile highly appreciated by consumers. Thousands of volatiles have been identified for the unique aroma profile. Among them, fatty acid esters have been identified as the main contributors to the aroma profile. In addition, many non-ester minor compounds, many of which are more polar than the esters, have been identified to contribute to the characteristic aroma unique to Wuliangye baijiu. The analysis of these minor compounds has been challenging due to the dominance of esters in the sample. Thus, it is desirable to fractionate the aroma extract into subgroups based on functional group or polarity to simplify the analysis. This study attempts a new approach to achieve simultaneous volatile extraction and fractionation using tandem LiChrolut EN and silica gel solid-phase extraction (SPE) columns. A baijiu sample (10 mL, diluted in 40 mL of water) was first passed through the LiChrolut EN (1.0 g) column. The loaded LiChrolut EN column was then dried with air and coupled with a silica gel (5.0 g) SPE column with anhydrous Na2SO4 (10.0 g) in between. The volatile compounds were eluted from the LiChrolut EN column and simultaneously fractionated on the silica gel column based on polarity. The simultaneous extraction and fractionation technique enabled the fractionations of all fatty acid esters into less polar fractions. Fatty acids, alcohols, pyrazines, furans, phenols, hydroxy esters, and other polar compounds were collected in more polar fractions. This technique was used to study the volatile compounds in Wuliangye, Moutai, and Fengjiu baijiu. In addition to fatty acid esters, many minor polar compounds, including 2,6-dimethylpyrazine, 2-ethyl-6-methylpyrazine, 2-ethyl-3,5-dimethylpyrazine, p-cresol, and 2-acetylpyrrole, were unequivocally identified in the samples. The procedure is fast and straightforward, with low solvent consumption.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号