首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A new sorbent S-benzyldithiocarbazate (SBDTC) modified activated carbon (AC-SBDTC) was prepared and studied for preconcentration for trace mercury(II) prior to inductively coupled plasma atom emission spectrometry (ICP-AES). The experimental conditions were optimised with respect to different experimental parameters using both batch and column procedures in detail. The optimum pH value for the separation of Hg(II) on the new sorbent was 3, while the adsorption equilibrium was achieved in less than 5?min. Complete elution of the adsorbed metal ions from the sorbent surface was carried out using 5?mL of 0.25?mol?L?1 of HCl and 2% CS(NH2)2. Common coexisting ions did not interfere with the determination. The maximum static adsorption capacity of the sorbent under optimum conditions was found to be 0.55?mmol?g?1. The detection limit of the present method was found to be 0.09?ng?mL?1, and the relative standard deviation (RSD) was lower than 2.0%. The procedure was validated by analysing the certified reference river sediment material (GBW 08301, China), the results obtained were in good agreement with standard values. This sorbent was successfully employed in the separation and preconcentration of trace Hg(II) from the natural water samples yielding 80-fold concentration factor.  相似文献   

2.
A solid phase extraction procedure for the separation and preconcentration of trace amounts of Cd(II) and Pb(II) using the alizarin red S modified TiO2 nanoparticles prior to their determination by flame atomic absorption spectrometry has been proposed. The influences of some analytical parameters such as pH, flow rates of sample and eluent, type and concentration of the eluent, and interfering ions on the recovery of Cd(II) and Pb(II) by the sorbent were investigated. The analytes were quantitatively sorbed from the aqueous solution at pH 5.5 onto a microcolumn packed with the sorbent and recovered with 2.0?mL of 1.5?mol?L?1 hydrochloric acid. Under the optimum experimental conditions, the detection limits for Cd(II) and Pb(II) were 0.11 and 0.30?ng?mL?1 and the relative standard deviations for ten replicate measurements of 5.0 and 50.0?ng?mL?1 of Cd(II) and Pb(II) were 2.1 and 1.9%, respectively. A sample volume of 200?mL resulted in a preconcentration factor of 100. The method was successfully applied to the determination of Cd(II) and Pb(II) in water and biological samples, and accuracy was examined by the recovery experiments, independent analysis using electrothermal atomic absorption spectrometry, and analysis of a water standard reference material (SRM 1643e).  相似文献   

3.
A chelating matrix prepared by immobilising folic acid on silica gel-bound amine phase was used as a new solid-phase extractant. This sorbent has been developed only for preconcentration of trace Pb(II) prior to determination by inductively coupled plasma atomic emission spectrometry (ICP-AES). Experimental conditions were investigated by batch and column procedures. The optimum pH value for the separation of Pb(II) on the new sorbent was 4.0. The adsorbed Pb(II) was quantitatively eluted by 2.0?cm3 of 0.5?mol?dm?3 of HCl. Common coexisting ions did not interfere with the separation and determination of Pb(II). The maximum static adsorption capacity of the sorbent under optimum conditions was found to be 69.23?mg?g?1 for Pb(II). The detection limit of the method defined by International Union of Pure and Applied Chemistry was 0.28?ng?cm?3. The relative standard deviation (RSD) of the method was lower than 2.0% (n?=?8). The developed method has been validated by analysing certified reference materials and successfully applied to the determination of Pb(II) in water samples with satisfactory results.  相似文献   

4.
Almond skin was used as a biosorbent by solid-phase extraction for the preconcentration of manganese(II) before the determination by flame atomic absorption spectrometry. Characterization of almond skin was performed by infrared spectroscopy. The functional groups of the almond skin surface were shown to be beneficial for the adsorption of manganese(II). At pH 6.0, the manganese(II) ions were retained on the almond skin and afterward quantitatively eluted using 1.5?mol?L?1 nitric acid. The pH, flow rate and volume of sample, concentration, and flow rate of eluent and interfering ions were characterized. Using a sample size of 30?mL, a linear dynamic range of 1–120?µg?L?1 was obtained. A detection limit of 0.24?µg?L?1 manganese(II) and a relative standard deviation of 1.6% at 30?µg?L?1 were achieved. The accuracy of the present procedure was evaluated by the determination of manganese(II) in a certified reference material (GSB07-1189-2000). The protocol was also used for the determination of manganese(II) in wastewater. The fortified recoveries were from 99.0 to 99.4%.  相似文献   

5.
A new, simple, fast and reliable solid-phase extraction method has been developed for separation/preconcentration of trace amounts of Pb(II) using dithizone/sodium dodecyl sulfate-immobilized on alumina-coated magnetite nanoparticles, and its determination by flame atomic absorption spectrometry (FAAS) and graphite furnace atomic absorption spectrometry (GFAAS) after eluting with 4.0?mol?L?1 HNO3. Optimal experimental conditions including pH, sample volume, eluent concentration and volume, and co-existing ions have been studied and established. Under the optimal experimental conditions, the preconcentration factor, detection limit, linear range and relative standard deviation of Pb(II) using FAAS technique were 280 (for 560?mL of sample solution), 0.28?ng?mL?1, 1.4?C70?ng?mL?1 and 4.6% (for 10?ng?mL?1, n?=?10), respectively. These analytical parameters using GFAAS technique were 300 (for 600?mL of sample solution), 0.002?ng?mL?1, 0.006?C13.2?ng?mL?1 and 3.1% (for 5?ng?mL?1, n?=?10), respectively. The presented procedure was successfully applied for determination of Pb(II) content in opium, heroin, lipstick, plants and water samples.  相似文献   

6.
A new ionic liquid modified silica gel sorbent was prepared from the reaction of active silica gel with N-3-(-3-triethoxysilylepropyl)-3-methylimidazolium chloride ([(TESP)MIm]Cl). This sorbent was exploited as solid phase extractant for separation and preconcentration of metal ions prior to their determination by inductively coupled plasma atomic emission spectrometry (ICP-AES). It was found that it can selectively adsorb Fe(Ш). Identification of the surface modification was performed on the basis of FT-IR. Experimental conditions for effective adsorption of trace Fe(Ш) were optimised using both batch and column procedures. At pH 3, Fe(Ш) could be quantitatively adsorbed and completely eluted by using 2?mL of 0.1?mol?L?1 of HCl. 150?mL of sample solution was adopted as the maximum sample volume and a high enrichment factor of 75 was obtained. Most common coexisting ions did not interfere with the separation and preconcentration of Fe(Ш) at optimal conditions. The maximum static adsorption capacity of the sorbent was 37.0?mg?g?1. The detection limit of the present method was 0.48?µg?L?1, and the relative standard deviation (R. S. D.) was lower than 1.7%. The method was successfully applied to the preconcentration of trace Fe(Ш) in biological and natural water samples with satisfactory results.  相似文献   

7.
A new solid-phase extraction method utilising polyacrylonitrile activated carbon fibres (PAN-ACFs) as adsorbent was developed for the preconcentration of trace metal ions prior to their determination by inductively coupled plasma optical emission spectrometry (ICP-OES). The PAN-ACFs oxidised with nitric acid were characterised by FT-IR, XRD, SEM and BET analysis. Then the resulting PAN-ACFs were used as solid-phase adsorbent for simultaneously determination of trace Al(III), Be(II), Bi(III), Cr(III), Cu(II), Fe(III) and Pb(II) ions in aqueous solutions. The influences of the analytical parameters on the recoveries of the studied ions were investigated. The optimum experimental conditions of the proposed method were pH: 6.0; eluent concentration and volume: 3.0 mL of 1.5 mol L?1 nitric acid; flow rates of sample and eluent solution: 1.5 mL min?1. The preconcentration factors were found to be 67 for Al(III), Bi(III); 83 for Cr(III), Cu(II), Fe(III) and 50 for Be(II), Pb(II). The precision of this method was in range of 1.5%~3.5% and the detection limit of this metal ions was between 0.06~1.50 μg L?1. The developed method was validated by the analysis of a certified reference sample and successfully applied to the determination of trace metal ions in water samples with satisfactory results.  相似文献   

8.
A simple and rapid solid phase extraction?Cflow injection procedure is developed for on-line trace determination of Cu(II) and Pb(II) by flame atomic absorption spectrometry (FAAS). Multi-walled carbon nanotubes modified with a new Schiff??s base, 2,2??-(1E, 1E??)-(4-Methyl-1, 2-phenylene) bis (azen-1-yl-1-ylidine) bis (Methane-1-yl-1-ylidene) diphenol was used as a novel adsorbent material. Quantitative simultaneous extraction was obtained at pH 7.0. The retained metal ions were then eluted efficiently with 1.0?M HNO3 into the nebulizer of FAAS for on-line determination. Different variables affecting the preconcentration efficiency, including pH, eluent concentration, sample and eluent flow rates and sample loading time, were optimized. Using 3?min preconcentration of sample solution at flow rate of 5?mL?min?1 provided the enrichment factors of 20 and 21.5 for Cu(II) and Pb(II), respectively, at a sampling frequency of 17?h?1. The detection limits (3??) were found to be 0.80 and 1.80???g?L?1 for Cu(II) and Pb(II), respectively; and the relative standard deviations at 0.05???g?mL?1 of these metal ions were 1.7 and 1.8% (n?=?8), respectively. The accuracy was assessed by analysis of a certified reference material NKK-916 and the obtained results are in good agreement with certified amounts of Cu(II) and Pb(II). The proposed method was successfully applied to the determination of target analytes in different real samples.  相似文献   

9.
Expanded polystyrene (EPS) foam waste (white pollutant) was utilised for the synthesis of novel chelating resin i.e. EPS-N = N-α-Benzoin oxime (EPS-N = N-Box). The synthesised resin was characterised by FT-IR spectroscopy, elemental analysis, and thermogravimetric analysis. A selective method for the preconcentration of Pb(II) ions on EPS-N = N-Box resin packed in mini-column was developed. The sorbed Pb(II) ions were eluted with 5.0 mL of 2.0 mol L?1 HCl and determined by microsample injection system coupled flame atomic absorption spectrometry (MIS-FAAS). The average recovery of Pb(II) ions was achieved 95.5% at optimum parameters such as pH 7, resin amount 400 mg, flow rates 1.0 mL min?1 (of eluent) and3.0 mL min?1 (of sample solution). The total saturation capacity of the resin, limit of detection (LOD) and limit of quantification (LOQ) of Pb(II) ions were found to be 30 mg g?1, 0.033 μg L?1 and 0.107 μg L?1, respectively with preconcentration factor of 300. The accuracy, selectivity and validation of the method was checked by analysis of sea water (BCR-403), wastewater (BCR-715) and Tibet soil (NCS DC-78302) as certified reference materials (CRMs). The proposed method was applied successfully for the trace determination of Pb(II) ions in aqueous samples.  相似文献   

10.
We have developed a cloud point extraction procedure based on room temperature ionic liquid for the preconcentration and determination of mercury in water samples. Mercury ion was quantitatively extracted with tetraethyleneglycol-bis(3- methylimidazolium) diiodide in the form of its complex with 5,10,15,20-tetra-(4-phenoxyphenyl)porphyrin. The complex was back extracted from the room temperature ionic liquid phase into an aqueous media prior to its analysis by spectrofluorimetry. An overall preconcentration factor of 45 was accomplished upon preconcentration of a 20?mL sample. The limit of detection obtained under the optimal conditions is 0.08?μg mL?1, and the relative standard deviation for 10 replicate assays (at 0.5?g mL?1 of Hg) was 2.4%. The method was successfully applied to the determination of mercury in tap, river and mineral water samples.
Figure
In this work, a novel and sensitive analytical methodology for mercury preconcentration and determination in different water samples using ionic liquid was developed. The use of room temperature ionic liquid‘s biphasic systems as an alternative to conventional solvents offers several advantages including safety and high capacity to extract Hg(II) and other elements with high recoveries. ?onic liquid in combination with porphyrin complexing reagent was successfully applied in this study for the extraction and preconcentration of Hg(II). Likewise, a fast and quantitative back extraction of the analyte from room temperature ionic liquid phase into aqueous phase was possible, allowing its further determination by spectrofluorimetry. The preconcentration method allowed mercury determination in tap, river and mineral water samples at trace levels with high accuracy and reproducibility.  相似文献   

11.
A new extraction flotation spectrum method for indirect determination of trace amounts of sulfide by ammonium sulfate‐ethanol‐water system was developed. It showed that Cu(II) could combine with S2? into precipitate (CuS) which was floated in the surface of ethanol and water in the presence of ammonium sulfate. The sulfide can be indirectly determined by determining the flotation yield of Cu(II). The linear range from 2.4 × 10?8to 3.2 × 10?6g/mL and the detect limit of 2.0 × 10?8g/mL was achieved. The results showed the determination of S2? was not affected by Pb(II), Zn(II), Cd(II), Fe(II), Co(II),Ni(II), Mn(II) and Cl?, Br?, I?, etc. In the paper, the method was successfully applied to the determination of a trace amount of sulfide in polluted water samples with the advantages of simplicity of equipment, rapidity, low cost, etc.  相似文献   

12.
We have synthesised water soluble CdS/ZnS core-shell quantum dots (QDs) capped with mercaptoacetic acid (MAA). They were characterised by UV–vis absorption spectroscopy, fluorescence spectroscopy, FT-IR and transmission electron microscopy. Such QDs can be used as fluorescent probes for the determination of metal ions because they quench the fluorescence of the QDs. The QDs exhibit absorption and emission bands at 345?nm and 475?nm respectively, which is more longer wavelength compared to MAA-capped CdS QDs and obviously is the result of the larger particle size. The fluorescence intensity of CdS-based QDs is strongly enhanced by coating them with a shell of ZnS. In addition, such functionalised QDs are more sensitive to Hg(II) ions. Parameters such as pH, temperature and concentration of the QDs have been optimised. A high selectivity and sensitivity toward Hg(II) ions is obtained at pH 7.4 and a concentration of 12.0?mg of QDs per L. Under optimum conditions, the fluorescence intensity of CdS/ZnS QDs is linearly proportional to the concentration of Hg(II) in the range from 2.5 to 280?nM, with a detection limit of 2.2?nM. The effect of potentially interfering cations was examined and confirmed the high selectivity of this material.
Figure
Water soluble Mercaptoacetic acid (MAA)-capped CdS/ZnS core-shell quantum dots (QDs) was synthesised and characterised by using the UV-Visible absorption spectroscopy, Fluorescence spectroscopy, Fourier Transform Infrared Spectroscopy (FT-IR) and Transmission Electron Microscopy (TEM). These functionalised QDs are used as fluorescence probe for the determination of Hg(II) ions, based on the fluorescence quenching of QDs. A high optical selectivity and sensitivity toward Hg(II) ions was obtained at pH 7.4 of Tris–HCl buffer with a QDs concentration of 12.0?mgL?1. Under optimum conditions, the fluorescence intensity of CdS/ZnS QDs was linearly proportional to mercury ions concentration in the range 0.025?×?10?7 to 2.8?×?10?7?M with a detection limit of 2.2?×?10?9?M. The effect of common foreign ions on the fluorescence of the QDs was examined which confirmed high selectivity of this material towards Hg(II) ions. Measurements of real samples also give satisfactory results which were in good agreement with those obtained using Atomic Absorption Spectroscopy. Therefore, these QDs are not only sensitive and of low cost, but also can be reliable for practical applications.  相似文献   

13.
A method was established for the preconcentration of trace Au(III), Pd(II) and Pt(IV) by activated carbon modified with 3,4-dihydroxycinnamic acid. The separation and preconcentration conditions of analytes were investigated, such as effects of pH, the contacting time, the sample ?ow rate and volume, the elution condition and the interfering ions. At a pH of 1.0, the maximum static sorption capacity of the sorbent was found to be 374.8, 96.6 and 137.5 mg g?1 for Au(III), Pd(II) and Pt(IV), respectively. The adsorbed metal ions were effectively eluted with 2.0 mL of 4% thiourea in 0.5 M HCl solution and determined by inductively coupled plasma optical emission spectrometry. The detection limit (3σ) of this method defined by IUPAC was found to be 0.12, 0.18 and 0.32 ?g L?1 for Au(III), Pd(II) and Pt(IV), respectively. The relative standard deviation (RSD) was lower than 3.0% (n = 8) towards standard solutions. The method has been validated by analysing certified reference materials and successfully applied to the determination of trace Au(III), Pd(II) and Pt(IV) in road sediments samples.  相似文献   

14.
A procedure has been proposed for the separation and preconcentration of trace amounts of thallium. It is based on the adsorption of thallium ions onto organo nanoclay loaded with 1-(2-pyridylazo)-2-naphthol (PAN). Thallium ions were quantitatively retained on the column in the pH range of 3.5–6.0, whereas quantitative desorption occurs with 5.0?mL of 5% ascorbic acid and thallium was determined by flame atomic absorption spectrometry. Linearity was maintained between 0.66?ng?mL?1–15.0?µg?mL?1?in initial solution. Detection limit was 0.2?ng?mL?1?in initial solution and preconcentration factor was 150. Eight replicate determinations of 2.0?µg?mL?1 of thallium in final solution gave a relative standard deviation of ±1.48%. Various parameters have been studied, such as the effect of pH, breakthrough volume and interference of a large number of anions and cations and the proposed method was used to determine thallium ions in water and standard samples. Determination of thallium ions in standard sample showed that the proposed method has good accuracy.  相似文献   

15.
A new solid-phase extraction method was developed for trace determination of Hg(II) by using a small amount of naked magnetite nanoparticles as an adsorbent. The magnetite nanoparticles were characterized by X-ray diffraction, scanning electron microscopy and transmission electron microscopy. The adsorbed Hg(II)-dithizone complex was eluted with 1.0 mL aliquot of an acidic 1-propanol solution prior to electrothermal atomic absorption spectrometry. A huge positive effect was found on the mercury adsorption by ionic strength. Under optimized condition, a linear calibration curve was obtained for mercury in the range of 0.2–50 ng mL?1 with relative standard deviation in the range of 0.5–2.0%. The limit of detection and enrichment factor were 0.01 ng mL?1 and 98.3, respectively. The effects of coexisting ions were studied extensively, and a new clean-up procedure was used to remove the matrix effects by using a simple sample pretreatment step using a little amount of magnetite nanoparticles. The method was successfully applied to the determination of Hg(II) in different water and human urine samples and a commercial sodium nitrate.  相似文献   

16.
A simple and reliable method for the extraction and determination of trace amounts of copper(Ⅱ) ions using activated carbon (AC) impregnated by a new Schiff base 5-[(4-heptyloxyphenyl)azo]-N-(4-propyloxyphenyl)-salicylaldimine (HPPS) and atomic absorption spectrometry is presented. Recovery efficiency and the influence of pH value, volume of sample solution, effect of different eluents, and interfering ions were evaluated. The limit of detection (3σ) was 2.62 ng.mL^-1 and the relative standard deviation (n=10) was 1.5%. Under optimum conditions, the copper ions were concentrated 25 fold using 250 mL of sample solution and 10 mL of eluent. This procedure has been successfully applied to the determination of copper in different water samples.  相似文献   

17.
A new sorbent was prepared by immobilization of 2,6-diaminopyridine on activated carbon and then used as a solid-phase extractant for trace Au(III), Pd(II) and Pt(IV) before their determination by ICP-AES. Effects of pH, the shaking time, the sample flow rate and volume, the elution condition and the potentially interfering ions were investigated. The optimum pH value is 1. The maximum static adsorption capacity for the three ions is 202.7, 38.5 and 30.1?mg?g?1, respectively. The adsorbed metal ions can be completely eluted by 2?mL of the eluent solution that contains 0.05?mol?L?1 HCl and 5% thiourea. Common other ions do not interfere. The detection limits (3??) are 0.16, 0.33 and 0.29?ng?mL?1, respectively. The relative standard deviation (RSD) was lower than 3.0% (n?=?8). The new sorbent was applied to the preconcentration of the three ions in ore and rock samples with satisfactory results.
Figure
Au(III), Pd(II), Pt(IV) are absorbed at pH 1. The maximum static adsorption capacity is 202.7, 38.5 and 30.1?mg?g?1. The eluent is 2?mL of the eluent solution that contains 0.05?mol?L?1 HCl and 5% thiourea. The relative standard deviation (RSD) was lower than 3.0% (n?=?8).  相似文献   

18.
By incorporation of synthesized magnetite nanoparticles (Fe3O4 NPs) coated with a new Schiff base into carbon paste electrode, a novel modified electrode was constructed for simultaneous determination of ultra trace amounts of Cd(II), Cu(II) and Hg(II). The complexation reaction of Schiff base with metal ions was studied spectrophotometrically. Under optimal conditions a detection limit of 0.20, 0.90 and 1.00 ng mL?1 for Cd(II), Cu(II) and Hg(II), respectively, was obtained. We take the advantages of the proposed method for simple, rapid, sensitive and selective simultaneous determination of trace amounts of hazardous Cd(II), Cu(II) and Hg(II) in water and foodstuff samples.  相似文献   

19.
A new indirect differential pulse polarographic (DPP) method is established for the trace determination of mercury(II). Because of its toxic effects on human health, trace determination of mercury is very important. An indirect method had to be used since no polarographic peak is observed in its direct determination. According to the standard potentials, the reaction between Sn(II) and Hg(II) was found suitable. The peak of Sn(II) at about ?0.40 V is sharp, high and very reproducible, which enables the determination of low concentrations of Hg(II). For this purpose, to a known amount of Sn(II) present in the polarographic cell (acetic acid, HAc, pH 1–2), the unknown Hg(II) sample is added and the quantitative reaction takes place directly in the cell. The Hg(II) concentration is calculated simply from the decrease of the Sn(II) peak. The limit of detection (LOD) was found as 2 × 10?7 M for S/N = 3. Interferences of some common cations, such as Fe, Cd, Cu, Zn and Pb and anions have been investigated. Only Pb had an overlapping peak with Sn(II). This peak overlap was eliminated simply by working at pH 2 (HAc electrolyte), because of the shift of the Pb peak in the Ac complex to ?0.7 V. This method was successfully applied to synthetic samples and raw salt sample taken from a salt lake in Turkey.  相似文献   

20.
A sensitive and selective solid-phase spectrophotometric method for the determination of trace amounts of Hg(II) cation in water is described. A complex was created with Hg(II) using 2,6-dimethyl-morpholine dithiocarbamate (DMMDTC) to form Hg(II)–(DMMDTC) and this complex was adsorbed onto microcrystalline naphthalene (MN) and then eluted with 5% acetic acid (in ethanol) solution. A preconcentration factor of 187 and a recovery of 95% were observed at pH of 5.0 and for 10 min. of extraction. The separated Hg(II) ions were quantified by using ultraviolet-visible spectrophotometer at 490.0 nm by creating a colored complex with dithizone in Triton X-100 surfactant media. Molar absorptivity and sandell’s sensitivity for the Hg(II)-dithizone were determined as 4.96 × 105 Lmol?1cm?1 and 0.4032 µg cm?2, respectively. The detection limit (LOD) was 1.7 μg L?1 under the optimized conditions of the analytical method.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号