首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
The purpose of the study was to determine the advantages of different mass spectrometric instruments and commercially available metabolite identification programs for metabolite profiling. Metabolism of tramadol hydrochloride and the excretion of it and its metabolites into human urine were used as a test case because the metabolism of tramadol is extensive and well known. Accurate mass measurements were carried out with a quadrupole time-of-flight mass spectrometer (Q-TOF) equipped with a LockSpray dual-electrospray ionization source. A triple quadrupole mass spectrometer (QqQ) was applied for full scan, product ion scan, precursor ion scan and neutral loss scan measurements and an ion trap instrument for full scan and product ion measurements. The performance of two metabolite identification programs was tested. The results showed that metabolite programs are time-saving tools but not yet capable of fully automated metabolite profiling. Detection of non-expected metabolites, especially at low concentrations in a complex matrix, is still almost impossible. With low-resolution instruments urine samples proved to be challenging even in a search for expected metabolites. Many false-positive hits were obtained with the automated searching and manual evaluation of the resulting data was required. False positives were avoided by using the higher mass accuracy Q-TOF. Automated programs were useful for constructing product ion methods, but the time-consuming interpretation of mass spectra was done manually. High-quality MS/MS spectra acquired on the QqQ instrument were used for confirmation of the tramadol metabolites. Although the ion trap instrument is of undisputable benefit in MS(n), the low mass cutoff of the ion trap made the identification of tramadol metabolites difficult. Some previously unreported metabolites of tramadol were found in the tramadol urine sample, and their identification was based solely on LC/MS and LC/MS/MS measurements.  相似文献   

2.
An approach has been developed for drug metabolism studies of non-radiolabeled compounds using on-line liquid chromatography/tandem mass spectrometry (LC/MS/MS) combined with chip-based infusion following fraction collection. The potential of this approach, which improves the data quality compared with only LC/MS analysis, has been investigated for the analysis of in vitro metabolites of tolcapone and talinolol, two compounds with well-characterized metabolism. The information-dependent LC/MS/MS analysis enables the characterization of the major metabolites while the chip-based infusion is used to obtain good product ion spectra for lower level metabolites, to generate complementary MS information on potential metabolites detected in the LC/MS trace, or to screen for unexpected metabolites. Fractions from the chromatographic analysis are collected in 20 second steps, into a 96-well plate. The fractions of interest can be re-analyzed with chip-based infusion on a variety of mass spectrometers including triple quadrupole linear ion trap (QqLIT or Q TRAP) and QqTOF systems. Acquiring data for several minutes using multi-channel acquisition (MCA), or signal averaging while infusing the fractions at approximately 200 nL/min, permits about a 50 times gain in sensitivity (signal-to-noise) in MS/MS mode. A 5-10 microL sample fraction can be infused for more than 30 min allowing the time to perform various MS experiments such as MS(n), precursor ion or neutral loss scans and accurate mass measurement, all in either positive or negative mode. Through fraction collection and infusion, a significant gain in data quality is obtained along with a time-saving benefit, because the original sample needs neither to be re-analyzed by re-injection nor to be pre-concentrated. Therefore, a novel hydroxylated talinolol metabolite could be characterized with only one injection.  相似文献   

3.
4.
A simple and rapid method using reversed-phase liquid chromatography/tandem mass spectrometry (LC/MS/MS) for the simultaneous determination of the urinary metabolites of benzene, toluene, xylene and styrene in human urine specimens and standard solutions is described. A hybrid quadrupole/time-of-flight (QqTOF) mass spectrometer was compared for the determination of metabolite of aromatic solvents in urine samples. The metabolites selected were: trans,trans-muconic acid, hippuric acid, o-, m- and p-methylhippuric acid and phenylglyoxylic acid. The compounds were well separated from each other on narrow-bore 1-mm i.d. reversed-phase LC C-18 columns. Average recoveries for loading 100 microL of urine samples varied from 88-110% and the quantification limits were less than 30 ng/mL for each analyte (3 ng/mL for trans,trans-muconic acid). The qualitative information obtained (mass accuracy, resolution and full-scan spectra) with the QqTOF mass spectrometer allows a secure identification of analytes in biological matrices.  相似文献   

5.
LC coupled to single (LC–MS) and tandem (LC–MS/MS) mass spectrometry is recognized as the most powerful analytical tools for metabolic studies in drug discovery. In this article, we describe five cases illustrating the utility of screening xenobiotic metabolites in routine analysis of forensic samples using LC–MS/MS. Analyses were performed using a previously published LC–MS/MS general unknown screening (GUS) procedure developed using a hybrid linear IT–tandem mass spectrometer. In each of the cases presented, the presence of metabolites of xenobiotics was suspected after analyzing urine samples. In two cases, the parent drug was also detected and the metabolites were merely useful to confirm drug intake, but in three other cases, metabolite detection was of actual forensic interest. The presented results indicate that: (i) the GUS procedure developed is useful to detect a large variety of drug metabolites, which would have been hardly detected using targeted methods in the context of clinical or forensic toxicology; (ii) metabolite structure can generally be inferred from their “enhanced” product ion scan spectra; and (iii) structure confirmation can be achieved through in vitro metabolic experiments or through the analysis of urine samples from individuals taking the parent drug.  相似文献   

6.
A new multi-target screening (MTS) procedure for drugs in blood and urine for toxicological analysis has been developed using a hybrid triple-quadrupole linear ion trap mass spectrometer (QTrap) for the fast detection and identification of 301 forensically important drugs, e.g. tranquilizers (benzodiazepines), hypnotics, drugs of abuse (opiates, cocaine, amphetamines, cannabinoids), antidepressants, neuroleptics, and some cardiac drugs, in one single liquid chromatography/tandem mass spectrometry (LC/MS/MS) analysis. Samples were extracted either with liquid-liquid extraction or solid-phase extraction. A multiple reaction monitoring (MRM) as survey scan and an enhanced product ion (EPI) scan as dependent scan were performed in an information-dependent acquisition (IDA) experiment. Finally, drug identification was carried out by library search with a newly developed MS/MS library based on EPI spectra at three different collision energies in positive mode. The advantage of this newly developed method is the possibility to detect and identify 301 drugs in one single LC/MS/MS run.  相似文献   

7.
The identification and structure elucidation of drug metabolites is one of the main objectives in in vitro ADME studies. Typical modern methodologies involve incubation of the drug with subcellular fractions to simulate metabolism followed by LC-MS/MS or LC-MS(n) analysis and chemometric approaches for the extraction of the metabolites. The objective of this work was the software-guided identification and structure elucidation of major and minor buspirone metabolites using capillary LC as a separation technique and ion trap MS(n) as well as electrospray ionization orthogonal acceleration time-of-flight (ESI oaTOF) mass spectrometry as detection techniques.Buspirone mainly underwent hydroxylation, dihydroxylation and N-oxidation in S9 fractions in the presence of phase I co-factors and the corresponding glucuronides were detected in the presence of phase II co-factors. The use of automated ion trap MS/MS data-dependent acquisition combined with a chemometric tool allowed the detection of five small chromatographic peaks of unexpected metabolites that co-eluted with the larger chromatographic peaks of expected metabolites. Using automatic assignment of ion trap MS/MS fragments as well as accurate mass measurements from an ESI oaTOF mass spectrometer, possible structures were postulated for these metabolites that were previously not reported in the literature.  相似文献   

8.
Paramethoxyamphetamine (PMA) is an amphetamine-like designer drug that has emerged recently on the European illicit drug market. This drug has a wicked reputation, as a number of lethal intoxications have occurred. A method using high-performance liquid chromatography coupled to ion trap based mass spectrometry (LC/MS) is described for the determination of this compound together with 3,4-methylenedioxymethamphetamine (XTC or MDMA), amphetamine and 3,4-methylenedioxyamphetamine (MDA) in human matrices. A liquid/liquid extraction (LLE) was applied to whole blood, urine and postmortem tissues. Reversed-phase liquid chromatography was performed on a narrow-bore phenyl-type column at a flow rate of 0.3 mL/min. A switch box allowed disposal of early-eluting irrelevant material to waste, protecting the mass spectrometer from contamination. The column effluent was directed into an ion trap mass spectrometer by a sonic spray ionization (SSI) interface. The method was validated for all three matrices, proving the applicability of SSI even when dealing with complex biological matrices. The within-and between-day precisions were less than 17.5% and accuracy was below 16.2%. Weighted (1/x) quadratic calibration curves were generated ranging from 10 to 1000 ng/mL (blood and urine) or 20 to 2000 ng/g (tissue) and correlation coefficients (r(2)) always exceeded 0.995. In addition, the mass spectrum of PMA is given together with a proposed fragmentation pattern for the obtained LC/MS spectrum. This information can be useful for future identification of PMA with LC/MS in biological matrices as well as in confiscated powders or tablets.  相似文献   

9.
Pelzing M  Neusüss C 《Electrophoresis》2005,26(14):2717-2728
Liquid chromatography (LC) nanoelectrospray-tandem mass spectrometry (MS/MS) is a key technology for the study of proteomics, with the main benefit to the characterization of sensitive peptides from complex mixtures. Capillary electrophoresis coupled to mass spectrometry (MS) has been taken into consideration sporadically due to the highly efficient separation and ability to handle low sample amount, yet classified as being less sensitive with respect to analyte concentration. The limitation in capillary zone electrophoresis (CZE) injection volumes can be overcome by on-line solid-phase extraction (SPE). Such an on-line SPE-CZE system was explored in combination with an ion trap (IT) mass spectrometer. Thus, it was possible to inject more than 100 microL sample solution on to the CZE capillary. Concentration limits of detection as low as 100 amol/microL were demonstrated for a peptide standard. This SPE-CZE-microelectrospray ionization (ESI)-MS/MS setup was compared directly to nanoLC/nanoESI using the same sample of a tryptic digest of bovine serum albumin (BSA) as a reference standard. Measurements were made on one IT mass spectrometer with identical acquisition parameters. Both chromatography systems enabled the separation and detection of low levels of peptides from a mixture of moderate complexity, with most peptides identified using both techniques; however, specific differences were obvious. The nanoLC-MS is about five times more sensitive than the CZE-MS, yet the difference was less pronounced than expected. The CZE-MS technique showed reduced loss of peptides, especially for larger peptides (missed cleavages) and is about four times faster than the nanoLC-MS approach.  相似文献   

10.
The potential of liquid chromatography combined with tandem mass spectrometry (LC/MS/MS) for the determination of pesticide metabolites in human urine at the sub-ppb level is explored. Metabolites from two organophosphorous pesticides, 4-nitrophenol (from parathion and parathion-methyl) and 3-methyl-4-nitrophenol (from fenitrothion), are taken as model analytes to conduct this study. After direct injection of the urine sample (10 microL), different approaches were evaluated in order to achieve correct quantitation of analytes using an electrospray ionisation (ESI) interface. Thus, the feasibility of using external calibration was checked versus the use of different isotope-labeled internal standards. The advantages of applying coupled-column liquid chromatography (LC/LC) as an efficient clean-up without any type of sample manipulation are also discussed. The combination of LC/LC with ESI-MS/MS allows the direct analysis of free metabolites in urine, as the automated clean-up performed by the coupled-column technique is sufficient for the removal of interferences that suppress the ionisation of analytes in the ESI source. Using this procedure with external calibration, good precision and recoveries, and detection limits below 1 ng/mL are reached with analysis run times of around 8 min. The hyphenated technique LC/LC/ESI-MS/MS is proved to be a powerful analytical tool, allowing the rapid, sensitive and selective determination of 4-nitrophenol and 3-methyl-4-nitrophenol in human urine without any sample treatment.  相似文献   

11.
A sensitive, integrated top-down liquid chromatography/mass spectrometry (LC/MS) approach, suitable for the near complete characterization of specific proteins in complex protein mixtures, such as inclusion bodies of an E. coli lysate, has been successfully developed using a hybrid linear ion trap/Fourier transform ion cyclotron resonance (FTICR) mass spectrometer. In particular, human growth hormone (hGH) (200 fmol) was analyzed with high sequence coverage (>95%), including the sites of disulfide linkages. The high mass accuracy and resolution of the FTICR mass spectrometer was used to reveal high charge state ions of hGH (22 kDa). The highly charged intact protein ions (such as the 17+ species) were captured and fragmented in the linear ion trap cell. The fragment ions from MS/MS spectra were then successfully analyzed in the FTICR cell in an on-line LC/MS run. Peptide fragments from the N-terminal and C-terminal regions, as well as large interior fragments, were captured and identified. The results allowed the unambiguous assignment of disulfide bonds Cys53-Cys165 and Cys182-Cys189, indicative of proper folding of hGH. The disulfide bond assignments were also confirmed by analysis of the tryptic digest of a sample of hGH purified from inclusion bodies. On-line LC/MS with the linear ion trap/FTICR yields high mass accuracy in both the MS and MS/MS modes (within 2 ppm with external calibration). The approach should prove useful in biotechnology applications to characterize correctly folded proteins, both in the early protein expression and the later processed stages, using only a single automated on-line LC/MS top-down method.  相似文献   

12.
As a continuation of our efforts to improve our high-flow on-line bioanalytical approach for high-throughput quantitation of drugs and metabolites in biological matrices by high-performance liquid chromatography (LC) and tandem mass spectrometry (MS/MS), we have developed a ternary-column on-line LC/MS/MS system with dual extraction columns used in parallel for purification and an analytical column for analysis. The advantage of the dual extraction column system is that sample analysis can take place in one of the extraction columns while the other column is being equilibrated. Thus, the equilibration time does not add to the run time, hence shortening the injection cycle time and increasing the sample throughput. Moreover, the use of two extraction columns in parallel increases the number of samples that can be injected before the system fails due to an overused extraction column. Such a system has successfully been used to develop and validate a positive ion electrospray LC/MS/MS bioanalytical method for the quantitative determination of a guanidine-containing drug candidate in rat plasma. The system used for this work utilized two Oasis HLB extraction columns (1 x 50 mm, 30 microm), one C18 analytical column (3.9 x 50 mm, 5 microm), a ten-port switching value and a tandem mass spectrometer. The on-line analysis was accomplished by the direct injection of 10 microL of the sample, obtained by mixing a rat plasma sample 1:1 with an aqueous internal standard solution. Selected reaction monitoring (SRM) was utilized for the detection of the analyte and internal standard. The standard curve range was 1.00-200 ng/mL. The intra- and inter-day precision and accuracy were within 6.6%. The on-line purification step lasted for only 0.3 min and total run time was only 1.6 min.  相似文献   

13.
This paper reports a liquid chromatographic/electrospray ionization mass spectrometric (LC/ESI-MS) method for profiling a wide range of structurally different sulfoconjugated compounds in urine and its application to the characterization of biomarkers for heavy metal toxicity in rat urine. Sulfoconjugates were first isolated by solid-phase extraction and the LC separation was performed on a reversed-phase column. Sulfoconjugates were detected in a triple-quadrupole mass spectrometer by simultaneously monitoring constant losses of 80 u (or 80 Th for doubly charged ions), precursors of m/z 80 (SO(3) (-*)) and precursors of m/z 97 (HSO4-). The ESI-MS detection conditions were optimized on dehydroepiandrosterone sulfate and estradiol sulfate and tested on other sulfoconjugates. The analysis of urine samples from humans and rats by using the developed method allowed the detection of about 15 peaks in each mode of detection. It was then applied to the investigation of heavy metal toxicity in rats. Comparative analysis of the chromatographic fingerprints of urine from control and uranium- and cadmium-treated rats showed several variations in the chromatographic pattern of the sulfoconjugates. Diagnostic m/z ratios were confirmed by analyzing individual urine samples and one of the observed variations seemed to be specific to uranium toxicity. The ion responsible for this variation has been identified as 4-ethylphenol sulfate by comparison of its chromatographic retention time and collision-induced dissociation mass spectra (MS(2) and MS(3) performed on a quadrupole ion trap instrument) with those of the synthesized compound.  相似文献   

14.
Xylazine is used in veterinary medicine for sedation, anesthesia, and analgesia. It has also been reported to be misused as a horse doping agent, a drug of abuse, a drug for attempted sexual assault, and as source of accidental or intended poisonings. So far, no data concerning human metabolism have been described. Such data are necessary for the development of toxicological detection methods for monitoring drug abuse, as in most cases the metabolites are the analytical targets. Therefore, the metabolism of xylazine was investigated in rat and human urine after several sample workup procedures. The metabolites were identified using gas chromatography (GC)–mass spectrometry (MS) and liquid chromatography (LC) coupled with linear ion trap high-resolution multistage MS (MS n ). Xylazine was N-dealkylated and S-dealkylated, oxidized, and/or hydroxylated to 12 phase I metabolites. The phenolic metabolites were partly excreted as glucuronides or sulfates. All phase I and phase II metabolites identified in rat urine were also detected in human urine. In rat urine after a low dose as well as in human urine after an overdose, mainly the hydroxy metabolites were detected using the authors’ standard urine screening approaches by GC–MS and LC–MS n . Thus, it should be possible to monitor application of xylazine assuming similar toxicokinetics in humans.
Figure
Reconstructed high-resolution mass chromatograms indicating xylazine and its phase I metabolites as well as the mass spectra with structures of xylazine and one of its hydroxy metabolites  相似文献   

15.
Identification of drug metabolites by liquid chromatography/mass spectrometry (LC/MS) involves metabolite detection in biological matrixes and structural characterization based on product ion spectra. Traditionally, metabolite detection is accomplished primarily on the basis of predicted molecular masses or fragmentation patterns of metabolites using triple‐quadrupole and ion trap mass spectrometers. Recently, a novel mass defect filter (MDF) technique has been developed, which enables high‐resolution mass spectrometers to be utilized for detecting both predicted and unexpected drug metabolites based on narrow, well‐defined mass defect ranges for these metabolites. This is a new approach that is completely different from, but complementary to, traditional molecular mass‐ or MS/MS fragmentation‐based LC/MS approaches. This article reviews the mass defect patterns of various classes of drug metabolites and the basic principles of the MDF approach. Examples are given on the applications of the MDF technique to the detection of stable and chemically reactive metabolites in vitro and in vivo. Advantages, limitations, and future applications are also discussed on MDF and its combinations with other data mining techniques for the detection and identification of drug metabolites. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

16.
Acylcarnitine profiles of diagnostic value were generated from the equivalent of 0.1 microL of raw urine using the continuous-flow liquid chromatography/fast-atom bombardment mass spectrometry (LC/FAB-MS) interface for sample introduction. Further analysis was accomplished by gradient LC/MS using a commercially available packed fused-silica microbore column.  相似文献   

17.
We have developed and implemented a novel mass spectrometry (MS) platform combining the advantages of high mass accuracy and resolving power of Fourier transform ion cyclotron resonance (FTICR) with the economy and speed of multiple ion traps for tandem mass spectrometry. The instruments are integrated using novel algorithms and software and work in concert as one system. Using chromatographic time compression, a single expensive FTICR mass spectrometer can match the throughput of multiple relatively inexpensive ion trap instruments. Liquid chromatography (LC)-mass spectrometry data from the two types of spectrometers are aligned and combined to hybrid datasets, from which peptides are identified using accurate mass from the FTICR data and tandem mass spectra from the ion trap data. In addition, the high resolving power and dynamic range of a 12 tesla FTICR also allows precise label-free quantitation. Using two ion traps in parallel with one LC allows simultaneous MS/MS experiments and optimal application of collision induced dissociation and electrontransfer dissociation throughout the chromatographic separation for increased proteome coverage, characterization of post-translational modifications and/or simultaneous measurement in positive and negative ionization mode. An FTICR-ion trap cluster can achieve similar performance and sample throughput as multiple hybrid ion trap-FTICR instruments, but at a lower cost. We here describe the first such FTICR-ion trap cluster, its performance and the idea of chromatographic compression.  相似文献   

18.
An analytical method was developed for the determination in urine of 2 metabolites of diazinon: 6-methyl-2-(1-methylethyl)-4(1H)-pyrimidinone (G-27550) and 2-(1-hydroxy-1-methylethyl)-6-methyl-4(1H)-pyrimidinone (GS-31144). Two of the urine sample preparation procedures presented rely on gas chromatography/mass selective detection (GC/MSD) in the selected ion monitoring mode for determination of G-27550. For fast sample preparation and a limit of quantitation (LOQ) of 1.0 ppb, urine samples were purified by using ENV+ solid-phase extraction (SPE) columns. For analyte confirmation at an LOQ of 0.50 ppb, classical liquid/liquid partitioning was used before further purification in a silica SPE column. An SPE sample preparation procedure and liquid chromatography/electrospray ionization/mass spectrometry/mass spectrometry (LC/ESI/MS/MS) were used for both G-27550 and GS-31144. The limit of detection was 0.01 ng for G-27550 with GC/MSD, and 0.016 ng when LC/ESI/MS/MS was used for both G-27550 and GS-31144. The LOQ was 0.50 ppb for G-27550 when GC/MSD and the partitioning/SPE sample preparation procedure were used, and 1.0 ppb for the SPE only sample preparation procedure. The LOQ was 1.0 ppb for both analytes when LC/ESI/MS/MS was used.  相似文献   

19.
A simple, isocratic liquid chromatographic (LC) method using volatile mobile phase constituents for the identification of related substances in erythromycin samples is described. For method development, evaporative light scattering detection (ELSD) was used. An XTerra RP18 column was used at 70 degrees C with a mobile phase consisting of acetonitrile-isopropanol-0.2M ammonium acetate pH 7.0-water (165:105:50:680). Mass spectral data were acquired on an ion trap mass spectrometer equipped with an electrospray interface operated in the positive ion mode. First, a library was created using MS/MS and MS(n) spectra of reference substances available in the laboratory. Using these reference spectra as interpretative templates, eight novel related substances in erythromycin samples were identified: N-demethylerythromycin E, erythromycin E N-oxide, anhydroerythromycin C, N-demethylerythromycin B, anhydro-N-demethylerythromycin A, pseudoerythromycin E enol ether, EF lacking the neutral sugar and EA lacking the neutral sugar.  相似文献   

20.
A method using liquid chromatography/tandem mass spectrometry (LC/MS/MS) has been developed for the determination of basal acetylcholine (ACh) in microdialysate from the striatum of freely moving rats. A microdialysis probe was surgically implanted into the striatum of the rats and Ringer's solution was used as the perfusion medium at a flow rate of 2 microL per minute. The samples were then analyzed off-line by LC/MS/MS experiments. The separation of ACh and choline (Ch) was carried out using reverse phase ion pair liquid chromatography with heptafluorobutyric acid as a volatile ion pairing reagent. Analytes were detected by electrospray ionization tandem mass spectrometry in the positive ion mode. The detection limit for ACh was 1.4 fmol on column, which is at least three times lower than previously reported. Three quaternary ammonium compounds in the rat brain microdialysate were also identified by tandem mass spectrometry experiments in which the unknown mass spectra were compared with standard reference compounds. These compounds were identified as carnitine, acetylcarnitine and (3-carboxypropyl)trimethylammonium. This is the first known report of the compound (3-carboxypropyl)trimethylammonium being found in rat brain.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号