首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Four groups of isomeric polynuclear aromatic hydrocarbons (PAH) were examined by gas chromatography/mass spectrometry (GC/MS) using positive-ion chemical ionization and negative-ion chemical ionization with a variety of reagent gases in order to evaluate the utility of each; differentiation of isomers was the ultimate goal. Hydrogen positive-ion chemical ionization (PICI) yielded different spectra for all but one isomer pair while retaining sensitivity comparable to electron-impact mass spectrometry. Several experimental conditions in the negative-ion mode afforded distinctly different spectra for isomeric PAH, but often sensitivities were reduced. The thirteen model compounds divided approximately into three classes according to the types and extent of reactions of the molecular anion. Class 1 gave as good sensitivity as hydrogen PICI; class 2 gave isomer-dependent spectra, but reduced sensitivity; class 3 gave no isomer differentiation, but greatly enhanced sensitivity.  相似文献   

2.
The explosive triacetone triperoxide (TATP) has been analyzed by gas chromatography/mass spectrometry (GC/MS) and sub-nanogram detection limits are reported by ammonia positive ion chemical ionization (PICI), electron ionization (EI) and methane negative ion chemical ionization (NICI). Analysis by methane PICI and ammonia NICI gave detection limits in the low nanogram range. Analyses were carried out on (linear) quadrupole and ion trap instruments. Analysis of TATP by PICI using ammonia reagent gas is the preferred analytical method, producing low limits of detection as well as an abundant (greater than 60% of base peak) diagnostic adduct ion at m/z 240 corresponding to [TATP + NH4]+. Isolation of the [TATP + NH4]+ ion with subsequent collision-induced dissociation (CID) produces extremely low abundance product ions at m/z values greater than 60, and the m/z 223 ion corresponding to [TATP + H]+ was not observed. Density functional theory (DFT) calculations at the B88LYP/DVZP level indicate that dissociation of the complex to form NH4+ and TATP occurs at energies lower than peroxide bond dissociation, while protonation of TATP leads to cleavage of the ring structure. These results provide a method for pico-gram detection levels of TATP using commercial instrumentation commonly available in forensic laboratories. As a point of comparison, a detection limit of 15 ng was obtained by flame ionization detection.  相似文献   

3.
A simple alternative method with minimal sample pretreatment is investigated for screening of amphetamines in small volume (using only 20 microL) of urine sample. The method is sensitive and selective. The method uses gas chromatography (GC) direct sample introduction (DSI) for on-line derivatization (acylation) of amphetamines to improve sensitivity. Furan as chemical ionization (CI) reagent in conjunction with tandem mass spectrometry (MS/MS) is used to improve selectivity. Low background with sharp protonated molecular ion peaks of analytes is the evidence of improvement in sensitivity and selectivity. Blank urine samples spiked with known amounts of amphetamine, methamphetamine, 3,4-methylenedioxyamphetamine, 3,4-methylenedioxymethamphetamine and 3,4-methylenedioxyethylamphetamine is analyzed. Selected ion monitoring of the characteristic product ions (m/z 119+136+150+163) using furan CI-MS/MS in positive ion mode is used for quantification. Limits of detection (LOD) between 0.4 and 1.0 ng mL(-1) and limits of quantitation (LOQ) between 1.0 and 2.0 ng mL(-1) are established. Linear response over the range of 1-1000 ng mL(-1) (r(2)>0.997) is observed for all analytes, except for methamphetamine (2.0-1000 ng mL(-1)). Good accuracy between 86 and 113% and precision ranging from 4 to 18% is obtained. The method is also tested on real samples of urine from suspected drug abusers. This method could be used for screening and determination of amphetamines in urine samples, however needs additional work for full validation.  相似文献   

4.
Anabolic steroids are structurally similar compounds, and their product-ion spectra obtained by tandem mass spectrometry under electrospray ionization conditions are quite difficult to interpret because of poly-ring structures and lack of a charge-retaining center in their chemical structures. In the present study, the fragmentation of nine anabolic steroids of interest to the racing industry was investigated by using triple quadrupole mass spectrometer, Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometer, and a linear ion trap instrument. With the aid of an expert system software (Mass Frontier version 3.0), accurate mass measurements, and multiple stage tandem mass spectrometric (MS(n)) experiments, fragmentation pathways were elucidated for boldenone, methandrostenolone, tetrahydrogestrinone (THG), trenbolone, normethandrolone and mibolerone. Small differences in the chemical structures of the steroids, such as an additional double-bond or a methyl group, result in significantly different fragmentation pathways. The fragmentation pathways proposed in this paper allow interpretation of major product ions of other anabolic steroids reported by other researchers in a recent publication. The proposed fragmentation pathways are helpful for characterization of new steroids. The approach used in this study for elucidation of the fragmentation pathways is helpful in interpretation of complicated product-ion spectra of other compounds, drugs and their metabolites.  相似文献   

5.
The atmospheric pressure chemical ionization (APCI) source for gas chromatography-mass spectrometry analysis has been evaluated for the screening of 16 exogenous androgenic anabolic steroids (AAS) in urine. The sample treatment is based on the strategy currently applied in doping control laboratories i.e. enzymatic hydrolysis, liquid–liquid extraction (LLE) and derivatization to form the trimethylsilyl ether-trimethylsilyl enol ether (TMS) derivatives. These TMS derivatives are then analyzed by gas chromatography tandem mass spectrometry using a triple quadrupole instrument (GC-QqQ MS/MS) under selected reaction monitoring (SRM) mode. The APCI promotes soft ionization with very little fragmentation resulting, in most cases, in abundant [M + H]+ or [M + H-2TMSOH]+ ions, which can be chosen as precursor ions for the SRM transitions, improving in this way the selectivity and sensitivity of the method. Specificity of the transitions is also of great relevance, as the presence of endogenous compounds can affect the measurements when using the most abundant ions. The method has been qualitatively validated by spiking six different urine samples at two concentration levels each. Precision was generally satisfactory with RSD values below 25 and 15% at the low and high concentration level, respectively. Most the limits of detection (LOD) were below 0.5 ng mL−1. Validation results were compared with the commonly used method based on the electron ionization (EI) source. EI analysis was found to be slightly more repeatable whereas lower LODs were found for APCI. In addition, the applicability of the developed method has been tested in samples collected after the administration of 4-chloromethandienone. The highest sensitivity of the APCI method for this compound, allowed to increase the period in which its administration can be detected.  相似文献   

6.
7.
A highly specific and sensitive assay for N-acetyl-L-aspartic acid has been developed. The trideuterated compound was synthesized and used as an internal standard for gas chromatography with negative-ion chemical ionization mass spectrometry. Urine samples were acidified and extracted with ethyl acetate, and the compounds converted into their pentafluorobenzyl ester derivatives. Under these conditions, sub-picogram amounts of the pure derivatives could be detected. Thus, only microliter volumes of urine samples have to be processed to achieve reliable quantification of "basal" levels of N-acetyl-L-aspartic acid.  相似文献   

8.
A rapid, specific and highly sensitive multi-residue method for the determination of anabolic steroid residues in bovine, pork and poultry muscle tissues was developed. The sample preparation involves enzymatic digestion followed by extraction with methanol. The crude extract was cleaned up by solid-phase extraction (SPE) combining C18 and NH2 columns. The detection was carried out by a highly sensitive liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) method using both positive and negative ionization modes. Natural and synthetic steroids covering different polarities could be extracted, concentrated and purified using one single method. Mobile phase composition and additives were optimized to achieve the highest sensitivity. The linearity was not good enough for quantitative analysis but the method was well-suited for qualitative confirmation. The method was validated according to the European Commission Decision 2002/657/EC. Decision limits (CCalpha) and detection capabilities (CCbeta) were below 0.5 ng g(-1) for all the compounds in the three types of meat studied. The developed method is suitable for routine analysis in our laboratories.  相似文献   

9.
A fast and sensitive method for the comprehensive screening of anabolic agents and other banned doping substances using gas chromatography/tandem mass spectrometry (GC/MS/MS) with an external ionization ion trap mass spectrometer is presented. The method takes advantage of the resolving power of MS/MS to eliminate background interferences, thus speeding up the chromatographic analysis. For each compound, different fragmentation reactions were studied and their collision energies optimized to obtain the best sensitivity in terms of their signal-to-noise ratio (S/N). A dramatic reduction in overall analysis time was achieved compared with other common approaches. More than 50 substances could finally be monitored in less than 7.4 min with detection limits (S/N >3) lower than 0.5 ng ml(-1) for most of the compounds with special sensitivity requirements according to the International Olympic Committee (IOC). A validation procedure for qualitative analysis was performed. The selectivity of the method showed that no interfering peaks were observed at the retention time of the analytes. Good intermediate precision, below 25% for most of the compounds, and robustness were observed. The optimized method was successfully applied to analyse more than 100 real human urine samples with optimum sensitivity and specificity rates.  相似文献   

10.
High resolution gas chromatography-mass spectrometry has been used to detect anabolic steroids in urine. With fused silica capillary columns connected directly to mass spectrometer, the anabolic steroids could be detected after extraction, hydrolysis, and derivatization with a sensitivity better then 1 ppb. In vivo excretion and metabolism has been investigated for androstanolone, methandriol, oxymesterone, quindenione, and boldenone.  相似文献   

11.
A sensitive and specific method using gas chromatography and negative-ion chemical ionization mass spectrometry is described for the determination of 5-fluoro-2'-deoxyuridine (FdUrd) in plasma. The method is based on the formation of the pentafluoropropionyl derivative of FdUrd and of its stable isotope as internal standard after sample clean-up by solid-phase extraction and purification by high-performance liquid chromatography. Quantification in plasma was possible down to 300 pg/ml. The method was applied to the analysis of plasma levels of FdUrd in mice and dogs.  相似文献   

12.
13.
Summary A highly sensitive and specific gas chromatographic-mass spectrometric (GC-MS) assay for the determination of benzidine in urine is reported. It is based on the solvent extraction of the hydrolysed benzidine conjugates, together with the deuterium-labelled benzidine-d8 added as an internal standard, and a two-phase derivatisation procedure using pentafluoropropionic anhydride (PFPA) in the presence of pyridine as the phase-transfer catalyst. The reaction is complete within 5 min at room temperature. The pentafluoropropyl derivatives are quantified through capillary column GC-MS using selected ion monitoring (SIM) in the negative-ion chemical ionisation mode (NICI). The lower limit of detection for benzidine was 0.5 g/l and the calibration plot showed linearity between 2 g/l and 200 g/l. The recovery of the analyte added to pooled urine was above 82%. Analysis of 20 urine samples from un-exposed persons and 20 urine specimens of workers employed in a polyurethane-making plant using this procedure showed no substances likely to manifest false positive results in the range of interest.  相似文献   

14.
Negative-ion chemical ionization (NCI) and collisionally activated mass spectra are presented for heptafluorobutyryl (HFB) esters of eight trichothecenes. The ion-source conditions have a dramatic effect on the NCI spectra and only at low source temperatures can intense parent ions, i.e., M? for bis- and tris-HFB esters (neosolaniol, HT-2 Toxin, monoacetosyscirpenol, fusarenon-X and deoxynivalenol) and [M-HF]? for mono-HFB esters (T-2 Toxin, Iso-T-2 Toxin, and diacetoxyscirpenol), be generated. High selectivity and a sensitivity down to picogram (0.2-2pg) levels were achieved with gas chromatography/NCI tandem mass spectrometry. Application to a spiked oats sample is described.  相似文献   

15.
Polycyclic aromatic hydrocarbons (PAHs) with four to six rings are potent carcinogens. This study analyzed ten of the sixteen US EPA priority PAHs using reversed-phase liquid chromatography/tandem mass spectrometry (LC/MS/MS) in selected reaction monitoring mode with two ionization sources: positive atmospheric pressure chemical ionization (APCI+) or positive elecrtrospray ionization (ESI+) with tropylium post-column derivatization. Several factors were investigated, including mobile phases, stationary phases of columns and chromatographic temperature, to determine how optimal separation and sensitivity might be achieved. Methanol used as an organic mobile phase provided better sensitivities for most PAHs than acetonitrile, although some PAHs co-eluted. Acidic buffers did not increase analyte signals. Use of Restek Pinnacle II PAH columns (250 x 4.6 mm or 250 x 2.1 mm, 5 microm) with water/acetonitrile gradient at 27 degrees C made possible a good separation of the ten analytes. [M]+. were the best precursor ions in both APCI and ESI, although fluoranthene could not be detected in ESI mode when tropylium post-column derivatization was performed. [M-28]+ and [M-52]+ were the major product ions of PAHs after collision-induced dissociation, a result of neutral losses of C(2)H(4) and (C(2)H(2))(2), respectively. Chromatographic separation for PAH isomers was crucial because the mass spectra were so similar that even MS/MS could not distinguish them from each other. The recoveries of sample preparations of PAHs spiked onto air-sampling filters ranged between 77.5 and 106% with relative standard deviations between 1.1 and 15.9%. This method was validated by analyzing NIST SRM 1649a (urban dust), producing results comparable with the certified PAH concentrations. The detection limits using APCI and ESI interfaces, defined as three times the noise levels, ranged between 0.23 and 0.83 ng and between 0.16 and 0.84 ng of on-column injection, respectively.  相似文献   

16.
The pressure requirements for chemical ionization g.c./F.t.m.s. which restrict mass resolution and accuracy are overcome through use of a pulsed valve that provides momentary reagent gas pressures. For alternate electron impact (EI)/chemical ionization (c.i.) g.c./F.t.m.s., similar resolution for both e.i. and c.i. data is demonstrated. The efficiency of chemical ionization with the pulsed valve is similar to static high pressure c.i. measurements of several model compounds. Results from the analysis of peppermint oil and a fuel additive illustrate the potential information available from a single g.c./F.t.m.s. experiment.  相似文献   

17.
18.
To study an expected transition of misoprostol from human blood into breast milk, a novel method for the determination of its active metabolite misoprostol acid (MPA) was developed. MPA was determined in serum and breast milk samples by an isotope dilution assay using gas chromatography/negative ion chemical ionization tandem mass spectrometry (GC/NICI-MS/MS). After addition of (15S)-15-methylprostaglandin E(2) (15-methyl-PGE(2)) as an internal standard, MPA was extracted from both matrices using a reversed-phase cartridge. The prostanoids were derivatized with O-2,3,4,5,6-pentafluorobenzylhydroxylamine hydrochloride (PFBHA) and 2,3,4,5,6-pentafluorobenzyl bromide (PFBB) to the pentafluorobenzyl oxime (PFBO)-pentafluorobenzyl ester (PFB) derivatives. The sample was subjected to thin-layer chromatography with ethyl acetate-hexane (1 : 1 (v/v)) as the developing solvent. The corresponding zone was extracted. After derivatization to the trimethylsilyl ether, MPA was determined by GC/NICI-MS/MS using the [molecule (M) - pentafluorobenzyl (PFB)](-) ([P](-)) ions as precursor in the negative ion chemical ionization mode. The product ions used for quantification were [P - 2TMSOH - C(6)F(5)CH(2)OH](-) (MPA) and [P - 2TMSOH - C(6)F(5)CH(2)OH - CO(2)](-)(15-methyl-PGE(2)), respectively. The limit of quantification for MPA was approximately 1 pg ml(-1) in breast milk and serum samples. The correlation coefficients of the calibration curves for MPA were r > 0.997 in the 0.5-2000 pg ml(-1) range for both tested matrices.  相似文献   

19.
A gas chromatography/mass spectrometry (GC/MS) method for determination of nine N-nitrosamines (NAs) in water is described. Two ionization modes, electron impact (EI) and chemical ionization (CI) with methanol, as well as different ion analysis techniques, i.e. full scan, selected ion storage (SIS) and tandem mass spectrometry (MS/MS) were tested. Chemical ionization followed by SIS resulted the mass spectrometric method of choice, with detection limits in the range of 1-2ng/L. Solid Phase Extraction (SPE) with coconut charcoal cartridges was applied to extract NAs from real samples, according EPA Method 521. Drinking water samples were collected from seven surface- and two groundwater treatment plants. Three surface water treatment plants were sampled before and after addition of O(3)/ClO(2) to observe the effect of disinfection on NAs' formation. N-nitrosodiethylamine (NDEA), n-nitrosodipropylamine (NDPA), n-nitrosomorpholine (NMOR) and n-nitrosodibutylamine (NDBA) were found up to concentrations exceeding three times the risk level of 10ng/L set by the California Department of Public Health. Because dermal adsorption has been recently indicated as a new contamination route of exposure to NAs for people who practice swimming activity, water samples from five swimming pools in the Bologna (Italy) area were collected. N-nitrosopyrrolidine (NPYR) was detected in all samples at concentrations larger than 50ng/L, likely as a disinfection by-product from the amino acid precursor proline, a main constituent of skin collagen.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号