首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 13 毫秒
1.
2.
《Analytical letters》2012,45(15):2424-2431
A sensitive LC-ESI-MS/MS method for determination of chlorzoxazone in rat plasma has been developed. Chromatographic separation was achieved on a Zorbax SB-C18 column, with 45:55 (v/v) acetonitrile–water as the mobile phase. A LC-ESI-MS/MS was performed in a multiple reactions monitoring (MRM) mode using target ions m/z 167.5→131.6 for chlorzoxazone and m/z 230.7→185.6 for phenobarbital (internal standard). The calibration plots were linear over the range of 10.0–2,000 ng/mL. Intra-day and inter-day precisions were better than 5.1% and 6.8%, respectively. The validated method was successfully used to analyze the drug in samples of rat plasma for pharmacokinetic study.  相似文献   

3.
《Analytical letters》2012,45(13):2041-2059
Abstract

A rapid liquid chromatography–electrospray ionization–tandem mass spectrometry (LC-ESI-MS/MS) method was developed for the determination of montelukast in human plasma. The extraction of montelukast from plasma (300 µL) involved protein precipitation. Quantitation was performed using LC-ESI-MS/MS, operating in the positive ion and selective reaction monitoring (SRM) mode. The total chromatographic run time for the analysis was 1.5 min. A linear dynamic range was established from 5 to 800 ng mL?1 for montelukast. The method was fully validated especially with regard to real subject sample analysis. It was successfully applied to a bioequivalence study in 18 healthy human subjects under fed condition (human subjects were allowed to eat as per the prescribed diet for bioequivalence study).  相似文献   

4.
《Analytical letters》2012,45(13):1671-1685
Abstract

A method has been developed to estimate primaquine in whole blood and urine by sensitive and selective high-performance liquid chromatography. Using the linear chain analogue of primaquine as the internal standard, a single-step extraction, normal-phase silica column with a basic mobile phase, levels down to 1 ng/ml of primaquine could be measured with good precision. Other anti-malarials like amodiaquine and pyrimethamine did not interfere in the assay. The major carboxylic acid metabolite of primaquine did not elute under the normal-phase chromatographic conditions. The method is suitable for use in clinical pharmacokinetic studies with primaquine.  相似文献   

5.
《Analytical letters》2012,45(16):1831-1841
Abstract

Primaquine in a flowing solvent is photolyzed with a 200 W Xe-Hg arc lamp and the intensely fluorescent photochemical product is measured in a fluorimeter. The effect of solvent composition and pH, irradiation time, and excitation conditions are evaluated. Primaquine in blood serum is measured by introducing a sample of blood serum into the flowing stream and performing the photochemical-fluorescence measurement. The fluorescence background of blood serum was very low allowing a detection limit of less than 0.1 μg/mL. Excellent recoveries were obtained.  相似文献   

6.
《Analytical letters》2012,45(1):68-83
Abstract

A simple and reliable high-performance liquid chromatographic (HPLC) method was developed for the determination of belotecan in the plasma, urine, and bile samples of rats. Belotecan was analyzed with HPLC using a C18 column with fluorescence detector. A mixture of acetonitrile–0.1 M potassium phosphate buffer at pH 2.4 (25:75, v/v) and 0.2% trifluoroacetic acid was used as the mobile phase. The lower limits of quantitation (LOQ) were 5 ng mL?1 for the plasma and 5 µg mL?1 for the urine and bile samples. The method has been readily applied for the routine pharmacokinetic study of belotecan in small laboratory animals.  相似文献   

7.
A rapid and sensitive assay based on high performance liquid chromatography-tandem mass spectrometry(LC-MS/MS) was developed for the determination of ranitidine(RAN) in human plasma with codeine as internal standard(IS).After protein precipitation with acetonitrile,the analyte and IS were separated on a Zorbax SB-Aq C18 column(150 mm×4.6 mm i.d.,5 μm) eluted with a mobile phase consisting of methanol/acetonitrile/10 mmol/L ammonium acetate containing 1% formic acid(pH=2.4)(volume ratio 12.5:12.5:75) at a flow rate of 1.0 mL/min.Detection was performed by electrospray ionization in the positive ion mode followed by the multiple reaction monito-ring(MRM) of the transitions of RAN at m/z 315.1→176.3 and of IS at m/z 300.1→165.1.The method was linear over a concentration range of 1―1000 ng/mL(r=0.9991) with a lower limit of quantitation(LLOQ) of 1 ng/mL and a limit of detection(LOD) of 0.3 ng/mL.Accuracy as relative error was from-0.01% to-1.7% and intra-day and inter-day precisions as relative standard deviation were ≤8.9% and ≤5.5%,respectively.The method was successfully applied to a pharmacokinetic study of ranitidine,getting a single oral dose(160 mg) to healthy volunteers.  相似文献   

8.
A rapid and sensitive liquid chromatography-tandem mass spectrometry(LC-MS/MS) method for the de- termination of cefotetan in human plasma was developed and validated. After the protein precipitation of sample with acetonitrile, the analyte and internal standard(IS), tramadol, were separated on a Zorbax XDB C8 column using ace- tonitrile/1%(volume fraction) formic acid(volume ratio 35:65, pH=2.5) as mobile phase at a flow rate of 1.0 mL/min with a 1 : 1 split. The detection was performed by electrospray ionization with positive ion mode, followed by multiple reaction monitoring of the transitions for cefotetan at m/z 576.3→460.2(quantifier) and m/z 576.3→432.2(qualifier) and for IS at m/z 264.1→58.1. Cefotetan and IS were eluted at 1.86 and 1.87 rain, respectively. The assay was linear over the concentration range of 0.1-100 gg/mL for 20 μL of human plasma only with intra- and inter-day preci- sions(expressed as the relative standard deviation) of less than 6.62% and accuracies(as relative error) of +1.31%. The method was applied to the pharmacokinetic study of a l-h intravenous infusion of 1.0 g of cefotetan disodium for human volunteers(n=6).  相似文献   

9.
Wang  Zhongqiong  Wang  Chengyi  He  Bing  Zhang  Wei  Liu  Li  Deng  Mingming    Muhan  Qi  Xiaoyi  Liang  Sicheng 《Chromatographia》2022,85(4):333-341

Daphnetin, which has been developed as a drug against obliterative vasculitis, can be rapidly and stereoselectively metabolized to an active 8-O-methylated metabolite, namely daphnetin 8-methyl ether (daphnetin-Me). Herein, a rapid, sensitive and reliable ultrafast liquid chromatography tandem mass spectrometry (UFLC-MS/MS) method was developed and validated to simultaneously determine daphnetin and daphnetin-Me in rat plasma after intragastric administration. The MS quantification for the two analytes and 3-aminocoumarin (internal standard, IS) was carried out on a triple quadrupole mass spectrometer using an ESI source in positive multiple reaction monitoring mode (daphnetin: m/z 179.15?→?51.10; daphnetin-Me: m/z 193.30?→?150.05; IS: m/z 162.00?→?106.20). The method exhibited a broad linear range of 1–2000 ng mL?1. The intra- and inter- assay precisions (RSD%) were?≤?8.29% with the accuracies (RME%) within?±?5.95%. This newly developed method was successfully applied to a pharmacokinetic study of daphnetin after a single dose of 20 mg kg?1 in rats. Daphnetin and daphnetin-Me peaked almost at the same time. Compared with that of daphnetin, a 2.1-fold higher area under the concentration–time curve (AUC) for daphnetin-Me were observed. These results would be beneficial in facilitating further investigation of pharmacological mechanisms, as well as the rational application of daphnetin and daphnetin-containing herb preparations.

  相似文献   

10.
采用超高液相色谱-串联质谱法同时测定发泡聚苯乙烯材料中阻燃剂α,β,γ-六溴环十二烷(HBCD)。样品用乙腈进行萃取,选用Waters ACQUITY UPLC@BEH C18色谱柱分离,以乙腈-5 mmol·L-1乙酸铵溶液为流动相进行梯度洗脱,质谱中选用多反应监测模式分析。HBCD各异构体的质量浓度在一定范围内与峰面积呈线性关系,测定下限(10S/N)为0.2 mg·kg-1。加标回收率在81.7%~102%之间,测定值的相对标准偏差(n=7)小于15%。  相似文献   

11.
Pyrroloquinoline quinone (PQQ) is a powerful antioxidant coenzyme existing in diet, benefiting growth, development, cognition function, and the repair of damaged organs. However, a method for detecting PQQ in vivo was rarely described, limiting the research on the bioanalysis and metabolic properties of PQQ. In this study, a novel, simple, and efficient ultra-high performance liquid chromatography/tandem mass spectrometry (UPLC-MS/MS) method was developed and validated to quantify the concentration of PQQ in rat plasma. Detection through mass spectrometry was operated by multiple reaction monitoring (MRM) in negative electrospray ionization mode with ion transitions m/z 328.99→197.05 for PQQ and m/z 280.04→195.04 for the internal standard. The calibration curves were linear up to 10,000 ng/mL, with a lower limit of quantitation of 10 ng/mL. Inter-run and intra-run precision ranged from 1.79% to 10.73% and accuracy ranged from −7.73% to 7.30%. The method was successfully applied to a toxicokinetic study in Sprague–Dawley rats after the oral administration of PQQ disodium salt at doses of 250 mg/kg, 500 mg/kg, and 1000 mg/kg. The toxicokinetic parameters were subsequently analyzed, which may provide valuable references for the toxicokinetic properties and safety evaluation of PQQ.  相似文献   

12.
Chromatographia - A method for the extraction and quantification of carvedilol, enalaprilat, and perindoprilat in 50 µL human plasma, using high-performance liquid chromatography with...  相似文献   

13.
A rapid, sensitive and specific ultra performance liquid chromatography-electrospray ionization tandem quadrupole mass spectrometry method was developed and validated for the determination of clopidogrel in dog plasma. Plasma samples were deproteinized with acetonitrile and separated on a Waters BEH C18 column (1.7 μm, 50 mm × 2.1 mm id.) with isocratic elution at a flow-rate of 0.2 mL min?1 and mobile phase consisting of acetonitrile and water (containing 0.15% formic acid) (75:25, v/v). The single run analysis was as shorter as 2 min. Electrospray ionization in positive ion mode and multiple reaction monitoring were used for the quantification of clopidogrel with monitored transitions m/z 322 → 212 for clopidogrel and m/z 324 → 217 for internal standard (gliclazide). The intra- and inter-day precisions (RSD%) were less than 6.32 and 7.03%, and accuracy (RE%) between ?9.12 and 9.65% (n = 6). The extraction recovery of clopidogrel was 96.7%. The developed method was successfully applied to the pharmacokinetic study of clopidogrel tablets in dogs following oral administration at a single dose of 75 mg.  相似文献   

14.
《Analytical letters》2012,45(3):571-583
Abstract

A fast potentiometric determination method has been reported for pentazocine in human plasma without complicated pretreatments using a coated-wire potentiometric selective electrode. The sensing membrane was made by incorporating of ion-association complexes of pentazocine cation and sodium tetraphenyl borate (NaTPB) in a polyvinyl chloride. The sensor exhibited fast, stable, and linear Nernstian response over the range of 5 × 10?5 to 0.1 mol L?1 pentazocine with a slope of 57.8 mV per decade and with detection limit of 3.2 × 10?5 mol L?1. The proposed sensor has been used for determination of pentazocine in human plasma and urine.  相似文献   

15.
采用超高效液相色谱-串联质谱法快速测定牛肉和牛奶中青霉素类药物残留。样品以磷酸盐缓冲溶液提取、乙酸锌沉淀蛋白、正己烷脱脂,然后经HLB固相萃取柱净化后,采用超高效液相色谱-串联质谱分离检测,外标法定量。6种青霉素的线性范围均在25.0μg·L-1以内,检出限(3S/N)为2μg·kg-1,测定下限(10S/N)为5μg·kg-1。加标回收率在77.0%~99.8%之间,测定值的相对标准偏差(n=6)在3.7%~13%之间。  相似文献   

16.
To support preclinical pharmacokinetic investigation of 1-[4-[2-(4-bromobenzene-sulfonaminoethyl)phenylsufonyl]-3-(trans-4-methylcyclohexyl)urea (G004), a rapid, sensitive and specific high-performance liquid chromatography–electrospray ionization mass spectrometry (LC–ESI-MS) method was developed and validated. Glibenclamide was employed as internal standard. After liquid–liquid extraction the analyte was analyzed on a Kromasil C18 column (150 × 2.0 mm i.d.) with a mobile phase consisted of acetonitrile–water (0.05% acetic acid), 30:70 (v/v). The flow rate was 0.2 mL min−1. Detection was performed on a quadrupole mass spectrometer using an electrospray ionization interface and the selected-ion monitoring (SIM) mode. The retention time was about 3.5 and 4.2 min for Glibenclamide and G004, respectively. The assay was linear over the concentration range of 2.0–500.0 ng mL−1. Extraction Recovery of G004 in rat plasma was more than 87%. The intra- and inter-assay precision was lower than 11.5% (CV). This validated method was successfully applied to the pharmacokinetics of G004 in rats.  相似文献   

17.
A rapid, sensitive, and specific LC-MS/MS method was developed and fully validated for the detection of paeoniflorin only in rat plasma, and applied to pharmacokinetic studies, including intravenous, multi-dose oral and combined administrations with verapamil. In this study, tolbutamide was used as the internal standard, and the protein precipitation extraction method, using acetonitrile as the extraction agent, was used for the sample preparation. Subsequently, the supernatant samples were analyzed on a Phenomenex Gemini® NX-C18 column with a flow rate of 1.0 mL/min in a gradient elution procedure. In the extracted rat plasma, the method exhibited high sensitivity (LLOQ of 1.0 ng/mL) upon selecting ammonium adduct ions ([M+NH4]+) as the precursor ions and good linearity over the concentration range of 1.0–2000 ng/mL, with correlation coefficients >0.99. The intra- and inter-batch accuracy RE% values were within ±8.2%, and the precision RSD% values were ≤8.1% and ≤10.0%, respectively. The results show that the method can be successfully applied to quantitate paeoniflorin in biological samples. Additionally, paeoniflorin is subsequently confirmed to be the substrate of the P-gp transporter in vivo and in vitro for the first time, which would be necessary and beneficial to investigate the clinical safety and efficacy of PF with other drugs in the treatment of rheumatoid arthritis.  相似文献   

18.
Paracetamol/acetaminophen (APAP) is one of the most popular pharmacologically active substances used as an analgesic and antipyretic agent. The metabolism of this drug occurs in the liver and leads to the formation of two main metabolites—glucuronic acid and sulfate derivate. Despite the wide use of paracetamol in veterinary medicine, a handful of analytical methods were published for the determination of paracetamol residues in animal tissues. In this paper, a multimatrix method has been developed for the determination of paracetamol and two metabolites—paracetamol sulfate (PS) and p-Acetamidophenyl β-D-glucuronide (PG). A validation procedure was conducted to verify method reliability and fit purpose as a tool for analyzing acetaminophen and metabolites in muscle, liver, lung, and kidney samples from different species of animals. Established validation parameters were in agreement with acceptable criteria laid by the European legislation. The initial significant matrix effect was successfully reduced by implementing an internal standard—4-Acetamidophenyl β-D-glucuronide-d3 (PG-d3, IS). The usefulness of the developed method was verified by analyzing samples from an experiment in which paracetamol was administrated to geese.  相似文献   

19.
20.
Dapoxetine is used for the treatment of premature ejaculation. The present study developed an HPLC–MS/MS method to determine the levels of dapoxetine in human plasma processed using simple protein precipitation. Dapoxetine-d7 was selected as the internal standard. The established method was performed using a mass spectrometer equipped with an electrospray ionization source in multiple positive ion reactions to monitor the mode using the precursor-to-product ion transitions of m/z 306.2–157.2 and m/z 313.2–164.2 for dapoxetine-d7 and dapoxetine, respectively. The method was evaluated based on its selectivity, linearity, limit of quantification, precision, accuracy, matrix effects, dilution integrity, stability, and extraction recovery. As a result of the model used in the present study, the validated linear ranges of dapoxetine were determined to be 2.00~1000 ng/mL in plasma, and the selectivity, precision, accuracy, dilution integrity, stability, and extraction recovery met the accepted standard. No matrix interference was observed. The method was successfully validated and applied to pharmacokinetic studies in healthy Chinese volunteers during the fasting and postprandial periods, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号