1.
A sensitive and rapid magnetic nanoparticle-based fluorescent immunoassay for the determination of aflatoxin M1 in raw milk was developed. Aflatoxin M1 was converted to aflatoxin M1-o-carboxymethyl oxime. The aflatoxin M1-oxime was used for the preparation of aflatoxin M1-oxime-fluoresceinamine conjugate through the carbodiimide reaction. The aflatoxin M1-oxime-fluoresceinamine conjugate was characterized by ultraviolet–visible and infrared spectroscopy. Magnetic nanoparticles (Fe3O4) were synthesized and modified by 3-(aminopropyl)triethoxysilane. The size of initial (139?nm) and functionalized magnetic nanoparticles (147?nm) was determined by particle analysis. The optimal mass of immobilized antibody (25?µg) and optimal concentration of aflatoxin M1-oxime-fluoresceinamine conjugate (15?µg?mL?1) for magnetic nanoparticle-based fluorescent immunoassay were determined. The developed immunoassay provided a linear aflatoxin M1 concentration range from 3.0 to 100?pg?mL?1 in bovine milk. The detection limit was 2.9?pg?mL?1. The results of aflatoxin M1 magnetic nanoparticle-based fluorescent immunoassay in heat-treated milk and phosphate-buffered saline at pH 6.6 were compared. The influence of the somatic cell count, pH, and fat concentration in bovine milk on the aflatoxin M1 immunoassay was investigated. The influence of the milk species on the immunoassay was also characterized. The high fat concentration ovine milk depressed the sensitivity of the aflatoxin M1 immunoassay.  相似文献   

2.
We report on a new kind of non-covalent multi-label electrochemical immunoassay that was applied to simultaneously quantify the tumor markers CA15-3 and CA19-9. The method employs a nanohybrid composed of an ionomer and conductive titanium dioxide nanoparticles that act as a matrix support for the antibodies. The two antibodies (anti-CA153 and anti-CA199) were labeled (a) with a cobaltous dipyridine complex, and (b) with methylene blue. Labeling is based on cation-exchange interaction rather than on covalent conjugation. The redox potentials of the two labels are separated by an interval of 0.3 V. The resulting sandwich-type immunosensor was read out by differential pulse voltammetry. The potential sites and currents of the two redox probes reflect the concentration of the two analytes. The two analytes were determined with a detection limit of 1.6 U?mL?1 for CA19-9, and of 0.3 U?mL?1 for CA15-3.
Figure
A new non-covalent multi-label electrochemical immunoassay was applied to simultaneously quantify dual tumor markers. DPV performed the identification and quantification of dual analytes on same electrode surface.  相似文献   

3.
In this paper, a novel, low-cost electrochemiluminescence (ECL) immunosensor using core–shell Fe3O4–Au magnetic nanoparticles (AuMNPs) as the carriers of the primary antibody of carbohydrate antigen 125 (CA125) was designed. Graphene sheet (GS) with property of good conductivity and large surface area was a captivating candidate to amplify ECL signal. We successively synthesized functionalized GS by loading large amounts of quantum dots (QDs) onto the poly (diallyldimethyl-ammonium chloride) (PDDA) coated graphene sheet (P-GS@QDs) via self-assembly electrostatic reactions, which were used to label secondary antibodies. The ECL immunosensors coupled with a microfluidic strategy exhibited a wide detection range (0.005–50 U mL−1) and a low detection limit (1.2 mU mL−1) with the help of an external magnetic field to gather immunosensors. The method was evaluated with clinical serum sample, receiving good correlation with results from commercially available analytical procedure.  相似文献   

4.
In this work, we reported a sandwiched luminol electrochemiluminescence (ECL) immunosensor using ZnO nanoparticles (ZnONPs) and glucose oxidase (GOD) decorated graphene as labels and in situ generated hydrogen peroxide as coreactant. In order to construct the base of the immunosensor, a hybrid architecture of Au nanoparticles and graphene by reduction of HAuCl4 and graphene oxide (GO) with ascorbic acid was prepared. The resulted hybrid architecture modified electrode provided an excellent platform for immobilization of antibody with good bioactivity and stability. Then, ZnONPs and GOD functionalized graphene labeled secondary antibody was designed for fabricating a novel sandwiched ECL immunosensor. Enhanced sensitivity was obtained by in situ generating hydrogen peroxide with glucose oxidase and the catalysis of ZnONPs to the ECL reaction of luminol–H2O2 system. The as-prepared ECL immunosensor exhibited excellent analytical property for the detection of carcinoembryonic antigen (CEA) in the range from 10 pg mL−1 to 80 ng mL−1 and with a detection limit of 3.3 pg mL−1 (S N−1 = 3). The amplification strategy performed good promise for clinical application of screening of cancer biomarkers.  相似文献   

5.
A facile and ultrasensitive electrochemiluminescent (ECL) immunosensor for detection of prostate-specific antigen (PSA) was designed by using CdTe quantum dots coated silica nanoparticles (SiO2@QDs) as bionanolabels. To construct such an electrochemiluminescence immunosensor, gold nanoparticles-dotted graphene composites were immobilized on the working electrode, which can increase the surface area to capture a large amount of primary antibodies as well as improve the electronic transmission rate. The as-prepared SiO2@QDs used as bionanolabels, showed good ECL performance and good ability of immobilization for secondary antibodies. The approach provided a good linear response ranging from 0.005 to 10 ng?mL?1 with a low detection limit of 0.0032 ng?mL?1. Such immunosensor showed good precision, acceptable stability, and reproducibility. Satisfactory results were obtained for determination of PSA in human serum samples. Therefore, the proposed method provides a new promising platform of clinical immunoassay for other biomolecules.  相似文献   

6.
A novel electrochemical immunosensor for the determination of carcinoma antigen 125 (CA125) was developed by means of immobilizing CA125 antibody (anti-CA125) on gold nanoparticles (Au) and thionine (Thi)-modified carbon paste interface. To avoid the leak of hydrophilic gold nanoparticles and thionine from carbon paste interface, the Au-Thi-modified carbon paste electrodes (CPEs) were first treated in the mixture solution containing 10% HNO3 and 2.5% K2Cr2O7 for 1.5 min at +1.5 V to make the carbon surface with -COOH groups, which can react with -NH2 groups on the thionine molecule, in the meantime, gold nanoparticles were absorbed on the thionine surface. Subsequently, CA125 antibodies were assembled onto the surface of gold nanoparticles. The fabrication process of the immunosensor was characterized by fourier transform infrared spectroscopy (FTIR) and UV-vis absorption spectroscopy. The performance and factors influencing the performance of the immunosensor were studied in detail. A direct electrochemical immunoassay format was employed to detect CA125 antigen based on the current change before and after the antigen-antibody reaction. The current change was proportional to CA125 concentration ranging from 10 to 30 U/ml with a detection limit of 1.8 U/ml (at 3δ). The immunosensors were used to analyze CA125 in human serum specimens. Analytical results of clinical samples show that the developed immunoassay has a promising alternative approach for detecting CA125 in the clinical diagnosis.  相似文献   

7.
《Analytical letters》2012,45(11):1988-2000
Abstract

A novel, selective, and sensitive magnetic-mimetic enzyme fluorescence immunoassay method for antigen detection has been developed by taking advantage of a magnetic separation process and the amplification feature of the hemin label. This method is based on a twice amplified fluorescence signal. The signal is first amplified due to the ultrasmall size and the high surface-to-volume ratio of the silica-coated magnetite nanoparticles, which enable the nanoparticles to carry much more antibodies. Second, the mimetic enzyme (hemin) as a labeling reagent catalyzes the reaction of p-hydroxyphenyl acetic acid and H2O2 can further amplify the fluorescence signal. This protocol was also evaluated for a sandwich-type immunoassay of human IgG, and the calibration graph for human IgG was linear over the range of 0–100 ng mL?1 with a detection limit of 9.8 ng mL?1. This method can easily separate magnetic nanoparticles from the solution, which simplified the process and played a promising role for various applications in immunoassay.  相似文献   

8.
We describe here the preparation of carbon-coated Fe3O4 magnetic nanoparticles that were further fabricated into multifunctional core/shell nanoparticles (Fe3O4@C@CNCs) through a layer-by-layer self-assembly process of carbon nanocrystals (CNCs). The nanoparticles were applied in a photoluminescence (PL) immunosensor to detect the carcinoembryonic antigen (CEA), and CEA primary antibody was immobilized onto the surface of the nanoparticles. In addition, CEA secondary antibody and glucose oxidase were covalently bonded to silica nanoparticles. After stepwise immunoreactions, the immunoreagent was injected into the PL cell using a flow-injection PL system. When glucose was injected, hydrogen peroxide was obtained because of glucose oxidase catalysis and quenched the PL of the Fe3O4@C@CNC nanoparticles. The here proposed PL immunosensor allowed us to determine CEA concentrations in the 0.005–50 ng?·?mL-1 concentration range, with a detection limit of 1.8 pg?·?mL-1.
Figure
The Fe3O4@C@CNC was prepared and applied in a CEA immunosensor with the help of a flow-injection photoluminescence system.  相似文献   

9.
A simple and inexpensive immunosensor is reported for the rapid determination of Staphylococcus aureus B-1266 that uses Fe3O4–SiO2–NH2 nanoparticles as the direct signal label. The electrochemical immunoassay procedure includes the incubation of bacteria with excess magnetite nanoparticles, the magnetic separation of the free nanoparticles, a labeled immunocomplex formation on the surface of a planar electrode, and the electrochemical response from the magnetite nanoparticles in the immunocomplex. The electrochemical immunosensor allows for the selective and accurate detection of S. aureus from 10 to 105?CFU?mL?1 with a relative standard deviation lower than 10%. The limit of detection was 8.7?CFU?mL?1.  相似文献   

10.
A approach was successfully employed for constructing a solid‐state electrochemiluminescence (ECL) immunosensor by layer‐by‐layer self‐assembly of multiwall carbon nanotubes (MWCNTs)‐Nafion composite film, Ru(bpy)32+/nano‐Pt aggregates (Ru‐PtNPs) and Pt nanoparticles (PtNPs). The influence of Pt nanoparticles on the ECL intensity was quantitatively evaluated by calculating the electroactive surface area of different electrodes with or without PtNPs to immobilize Ru(bpy)32+. The principle of ECL detection for target α‐fetoprotein antigen (AFP) was based on the increment of resistance after immunoreaction, which led to a decrease in ECL intensity. The linear response range was 0.01–10 ng mL?1 with the detection limit of 3.3 pg mL?1. The immunosensor exhibited advantages of simple preparation and operation, high sensitivity and good selectivity.  相似文献   

11.
A rapid and ultrasensitive electrochemiluminescence (ECL) competitive immunoassay based on CdSe quantum dots (QDs) and the shorter chain as possible (cysteamine and glutaraldehyde) has been designed for the detection of salbutamol (SAL). Cysteamine and glutaraldehyde made coating antigen immobilize well on the gold electrode surface through the reaction between functional groups, which brought about the simplicity of the immunosensor to some extent. Transmission electron microscopy image, dynamic light scattering, photoluminescence, ultraviolet‐visible absorption and electrochemical impedance spectra were used to characterize the prepared CdSe QDs and the cysteamine/glutaraldehyde/Ovalbumin‐SAL/anti‐SAL‐QDs immunosensor. In the air‐saturated PBS buffer containing 0.1 M K2S2O8 and 0.1 M KCl (pH 9.0), a strong ECL emission of QDs can be observed which depended linearly on the logarithm of the salbutamol concentration with a wide range from 0.05 ng mL?1 to 100 ng mL?1, and a detection limit of 0.0056 ng mL?1. The sensitivity, repeatability, and specificity of the ECL immunosensor have been evaluated. The sensor has been applied to real samples with satisfactory results. This work will open new ways of detecting food additive residue based on QDs ECL in immunoassays.  相似文献   

12.
In the present study, a novel and ultrasensitive electrochemiluminescence (ECL) immunosensor based on luminol cathodic ECL was fabricated by using Au nanoparticles and Pt nanoparticles (nano-AuPt) electrodeposited on graphene–carbon nanotubes nanocomposite as platform for the detection of carcinoembryonic antigen (CEA). For this introduced immunosensor, graphene (GR) and single wall carbon nanotubes (CNTs) dispersed in chitosan (Chi-GR-CNTs) were firstly decorated on the bare gold electrode (GE) surface. Then nano-AuPt were electrodeposited (DpAu-Pt) on the Chi-GR-CNTs modified electrode. Subsequently, glucose oxidase (GOD) was employed to block the non-specific sites of electrode surface. When glucose was present in the working buffer solution, GOD immediately catalyzed the oxidation of glucose to in situ generate hydrogen peroxide (H2O2), which could subsequently promote the oxidation of luminol with an amplified cathodic ECL signal. The proposed immunosensor was performed at low potential (−0.1 to 0.4 V) and low concentration of luminol. The CEA was determined in the range of 0.1 pg mL−1 to 40 ng mL−1 with a limit of detection down to 0.03 pg mL−1 (S N−1 = 3). Moreover, with excellent sensitivity, selectivity, stability and simplicity, the as-proposed luminol-based ECL immunosensor provided great potential in clinical applications.  相似文献   

13.
The authors describe a method for signal amplification of label-free voltammetric immunosensors. A glassy carbon electrode (GCE) was modified with Prussian Blue-platinum nanoparticles (PB-PtNPs) as a redox-active species that gives a strong amperometric signal at 0.18 V (vs. Ag/AgCl). Benefitting from the excellent electrical conductivity and the strong catalytic activity to H2O2, the modified GCE gives a strongly enhanced signal. The PB-PtNPs were incorporated into a polyaniline (PANI) hydrogel to further enhance the signal. The signal response of the PB-PtNP-PANI/GCE is larger by a factor of 7.6 than that of PB-PtNP/GCE. In order to further improve electrical conductivity and immobilize antibody, gold nanoparticles (AuNPs) were deposited on the surface of the PB-PtNP-PANI hydrogel. The AuNP-PB-PtNP-PANI hydrogel nanocomposite on the GCE was used in an immunosensor for the model analyte carcinoma antigen 125 (CA125), a biomarker for epithelial ovarian cancer, by immobilizing the respective antibody on the modified GCE. A linear response found for the 0.01 to 5000 U mL?1 CA125 concentration range, with a detection limit of 4.4 mU mL?1 (at an S/N ratio of 3). The electrochemical sensitivity is as high as 119.76 μA·(U/mL)?1·cm?2. The detection of CA125 in human serum showed satisfactory accuracy compared to a commercial chemiluminescent microparticle immunoassay (CMIA).
Graphical abstract Schematic of a nanocomposites consisting of gold nanoparticles, Prussian Blue, platinum nanoparticles and polyaniline hydrogel as a signal multi-amplification sensing substrate for the ultrasensitive immuno detection of carcinoma antigen 125 (CA125).
  相似文献   

14.
An ultrasensitive multiplexed immunoassay method was developed at a disposable immunosensor array using mesoporous platinum nanoparticles (M-Pt NPs) as nonenzymatic labels. M-Pt NPs were prepared by ultrasonic method and employed to label the secondary antibody (Ab2) for signal amplification. The immunosensor array was constructed by covalently immobilizing capture antibody (Ab1) on graphene modified screen printed carbon electrodes (SPECs). After the sandwich-type immunoreactions, the M-Pt-Ab2 was bound to immunosensor surface to catalyze the electro-reduction of H2O2 reaction, which produced detectable signals for readout of analytes. Using breast cancer related panel of tumor markers (CA125, CA153 and CEA) as model analytes, this method showed wide linear ranges of over 4 orders of magnitude with the detection limits of 0.002 U mL−1, 0.001 U mL−1 and 7.0 pg mL−1 for CA125, CA153 and CEA, respectively. The disposable immunosensor array possessed excellent clinical value in cancer screening as well as convenient point of care diagnostics.  相似文献   

15.
We report on an ultrasensitive fluorescence immunoassay for human chorionic gonadotrophin antigen (hCG). It is based on the use of silica nanoparticles coated with a copolymer (prepared from a fluorene, a phenylenediamine, and divinylbenzene; PF@SiO2) that acts as a fluorescent label for the secondary monoclonal antibody to β-hCG antigen. In parallel, Fe3O4 nanoparticles were coated with polyaniline, and these magnetic particles (Fe3O4@PANI) served as a solid support for the primary monoclonal antibody to β-hCG antigen. The PF@SiO2 exhibited strong fluorescence and good dispersibility in water. A fluorescence sandwich immunoassay was developed that enables hCG concentrations to be determined in the 0.01–100 ng·mL?1 concentration range, with a detection limit of 3 pg·mL?1.
Figure
Fluorescence detection of prepared immune reagent nano-composites using the fluorescence cell  相似文献   

16.
We report on a novel electrochemiluminescent (ECL) immunoassay for the ultrasensitive determination of morphine by making use of a gold electrode which was modified with a nanocomposite film containing self-assembled polyamidoamine (PAMAM) CdS quantum dots and electrodeposited gold nanoparticles (Au-NPs). The highly uniform and well-dispersed quantum dots were capped with PAMAM dendrimers. Due to the synergistic effect of the modified quantum dots and the electrodeposited Au-NPs, the ECL response is dramatically enhanced. Under optimal experimental conditions, the immunoreaction between morphine and anti-morphine antibody resulted in a decrease of the ECL signal because of steric hindrance. The calibration plot is linear in the morphine concentration range from 0.2 to 180 ng?mL?1, with a detection limit as low as 67 pg?mL?1. The sensor was successfully applied to the determination of morphine in blood plasma. This kind of assay is expected to pave new avenues in label-free drug assays.
Figure
?  相似文献   

17.
Picloram (4-amino-3,5,6-trichloro-2-pyridincarboxylic acid) is one of the chlorinated pesticides. It is widely used for control of wood plants, wheat, barley and wide range of broadleaf weeds as a plant growth regulator. An immunosensor was developed for detection of picloram concentration in compost extracts and river water. The laccase-picloram was prepared. The magnetic core-shell (Fe3O4-SiO2) nanoparticles were modified with anti-picloram-IgG and attached to the surface of carbon paste electrode (CPE) with the aid of paramagnetism. Following competitive immunoreaction with picloram and the picloram-laccase to form immunocomplex, electrochemical measurement was carried out. After immunoassay, the electrode was immersed in glycin-hydrochloric acid buffer or polished with diamond paper for regeneration. The linear range for picloram detection was 1?×?10–4–10?µg?mL–1 with the correlation coefficient of 0.9936, and the detection limit is 1?×?10–4?µg?mL–1. The laccase labelled on the picloram for competitive immunoassay showed good activity, and the current response was strong and stable in electrochemical detection. The current reached 95% of the steady-state current within about 100?s. The proposed immunosensor exhibited good precision, sensitivity, selectivity, reusability, and storage stability.  相似文献   

18.
In this paper, a simple and sensitive amperometric immunosensor for simultaneous detection of four biomarkers by using distinguishable redox-probes as signal tags was proposed for the first time. In sandwich immunoassay format, four kinds of capture antibodies (C-Ab) were immobilized by gold nanoparticles (AuNPs) electro-deposited on the surface of glass carbon electrode (GCE); four kinds of detection antibodies (D-Ab) labeled with different redox probes (including anthraquinone 2-carboxylic acid (Aq), thionine (Thi), ferrocenecarboxylic acid (Fc) and tris(2,2’-bipyridine-4,4’-dicarboxylic acid) cobalt(III) (Co(bpy)33+)), were combined with 3,4,9,10-perylenetetracarboxylic acid (PTCA), poly(diallyldimethylammonium chloride) (PDDA) and AuNPs functionalized carbon nanotubes, and served as signal tracer. When four target antigens were present, differential pulse voltammetry (DPV) scan exhibited four well-resolved peaks, each peak indicated one antigen, and its intensity was quantitative correlational to the concentration of corresponding analyte. To verify the strategy, four biomarkers for diagnosis of colorectal carcinoma, including carcinoembryonic antigen (CEA), carbohydrate antigen (CA) 19-9 CA125, and CA242, were used as model analytes, the immunosensor exhibited high selectivity and sensitivity, and peak current displayed good linear relationship to logarithm concentration in the ranges from 0.016 to 15 ng mL−1 for CEA; 0.008 to 10 ng mL−1 for CA19-9; 0.012 to 12 ng mL−1 for CA125; 0.010 to 10 ng mL−1 for CA242, and low detection limits of 4.2, 2.8, 3.3 and 3.8 pg mL−1, respectively.  相似文献   

19.
We report on the construction of a label-free electrochemical immunosensor for detecting the core antigen of the hepatitis C virus (HCV core antigen). A glassy carbon electrode (GCE) was modified with a nanocomposite made from gold nanoparticles, zirconia nanoparticles and chitosan, and prepared by in situ reduction. The zirconia nanoparticles were first dispersed in chitosan solution, and then AuNPs were prepared in situ on the ZrO2-chitosan composite. In parallel, a nanocomposite was synthesized from AuNPs, silica nanoparticles and chitosan, and conjugated to a secondary antibody. The properties of the resulting nanocomposites were investigated by UV-visible photometry and transmission electron microscopy, and the stepwise assembly process was characterized by means of cyclic voltammetry and electrochemical impedance spectroscopy. An sandwich type of immunosensor was developed which displays high sensitivity to the HCV core antigen in the concentration range between 2 and 512?ng?mL?1, with a detection limit of 0.17?ng?mL?1 (at S/N?=?3). This immunosensor provides an alternative approach towards the diagnosis of HCV.
Fig
A sandwich-type immunosensor was constructed for the detection of HCV core Ag. AuNPs/ZrO2-Chits nanocomposites were prepared by in situ reduction method. AuNPs/SiO2-Chits nanocomposite integrated with secondary antibody (Ab2) without labeled HRP. The immunosensor displayed high sensitivity to HCV core antigen with a detection limit of 0.17?ng?mL?1 (S/N?=?3).  相似文献   

20.
An ultrasensitive electrogenerated chemiluminescence (ECL) immunoassay was proposed by using magnetic nanobeads (MNBs) as the carrier of ECL labels for ECL emission amplification. Carcinoembryonic antigen (CEA) and MNBs were initially immobilized on a platform in 1 : 1 molar ratio via sandwich immunoreaction. Subsequently, the MNBs were released from the platform and labeled with Ru(bpy)32+ species. After the MNBs with Ru(bpy)32+ were immobilized on an Au electrode, ECL of the Ru(bpy)32+ was measured for CEA determination. A linear relation between the ECL intensity and CEA concentration was obtained in a range of 1×10?14 to 3×10?13 mol/L (2.0 to 60 pg/mL) with a limit of detection of 8.0×10?15 mol/L (1.6 pg/mL).  相似文献   