首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A methodology for simultaneous preconcentration and determination of Cr(VI) from aqueous samples was developed using a membrane optode formed by physical inclusion of a Cr(VI) selective chromophore 1,5-diphenylcarbazide (DPC) into a plasticized cellulose triacetate matrix. The inclusion of an anion exchanger (Aliquat-336) was found to be effective for immobilization of both DPC and Cr(VI)-DPC complex in the optode matrix itself. The proportionality in intensity of the magenta color on the optodes loaded with varying amounts of Cr(VI) suggests its potential applications for screening of Cr(VI) in aqueous samples by visual colorimetry. On loading high amounts of Cr(VI) in the membrane optode, its color changes from magenta to yellow, which indicates the possibility of using it as a threshold detector for Cr(VI). The membrane optode was optimized in terms of obtaining maximum preconcentration efficiency for Cr(VI) and subsequent stable optical response proportional to the amount of Cr(VI) in the membrane optode sample. The membrane optodes were tested for Cr(VI) determination in tap water and seawater samples. Using this optode, Cr(VI) even at levels of 13.6 ppb could be quantitatively detected. The optodes developed in the present work were found to be stable, cost effective, easy to prepare and efficient for direct preconcentration and determination of Cr(VI) in a variety of aqueous samples using spectrophotometry. However, this membrane optode is for one time use only as the reaction of Cr(VI) with DPC is irreversible.  相似文献   

2.
A sensitive and selective method has been developed to determine Cr(III) and total Cr in natural water samples by ICP-AES with a Cr(III)-imprinted aminopropyl-functionalised silica gel adsorbent. The Cr(III)-imprinted and non-imprinted adsorbent were prepared by an easy one-step reaction with a surface imprinting technique. Their maximum static adsorption capacities for Cr(III) were 11.12 mg g?1 and 3.81 mg g?1, respectively. The relative selectivity factors (α r) for Cr(III)/Co(II), Cr(III)/Au(III), Cr(III)/Ni(II), Cr(III)/Cu(II), Cr(III)/Zn(II), and Cr(III)/Cr(VI), were 377, 21.4, 15.4, 27.7, 26.4, and 31.9, respectively. Under the optimal conditions, Cr(III) can be absorbed quantitatively, but Cr(VI) was not retained. Total chromium was obtained after reducing Cr(VI) to Cr(III) with hydroxyammonium chloride. The detection limit (3σ) for Cr(III) was 0.11 ng mL?1. The relative standard deviation was 1.2%. The proposed method has been validated by analysing two certified reference materials and successfully applied to the determination and speciation of chromium in natural water samples with satisfactory results.  相似文献   

3.
Increasing in the use of various chromium species over the past few decades has inevitably resulted in an increased flux of their metallic substances in aquatic life. Therefore, experimental work was developed to improve the physical and chemical characteristics of the prepared mesoporous SiO2–Al2O3 mixed oxides via a sol–gel process. The effective key parameter on the properties of the materials was achieved by the addition of carboxylate functional group such as Alph-hydroxyl isobuteric acid (AHIBA) during the gelation process and prior the calcinations step. Better performance of these carboxylate resins are attributed to the complexing ability of the carboxylate groups toward polyvalent chromium species which is added to the normal sorption properties of the oxides. Urea has been used as a means of producing an aluminum precipitate that is easier to filter than that produced by rapid addition of base. Introduction of Al and Si salts together to form mixed oxide modified the way of their substitution in the hosting resin than when they were separately added. The data revealed that mesoporous materials with very narrow pore diameter distribution (micron-sized) and high surface area were obtained. The surface areas and pore size distributions were mainly depend on SiO2 content. Systematic investigations were carried out on the set of the prepared mixed oxides with different porosity, cross-linking degree and exchange loading to find out the best sorbent for chromium removal. The final objective in all cases was aimed at determining feasible and economically reliable solution to the environmental problems related to the tannery industry.  相似文献   

4.
In the present study, ionic liquid-modified silica-coated magnetic nanoparticles (MNPs) were synthesised and applied as a new anion-exchange sorbent for extraction and determination of Cr(VI) followed by inductively coupled plasma atomic emission spectrometry. The characterisation of MNPs was carried out by scanning electron microscope, Fourier transform infrared and vibrating sample magnetometer. Experimental design and response surface methodology were used for optimisation of different parameters which affect extraction efficiency of Cr(VI). Under the optimised conditions, extraction recoveries within the range of 25–33% with relative standard deviations (RSD%, n = 4) within the range of 3.0–5.0% were obtained. The limit of detection was found to be 0.1 µg L?1. The linearity was studied in the range of 0.5-200 µg L?1 with the determination coefficient of 0.9958. Also, calculated Errors% for determination of Cr(VI) in the range of 5-15 depict that the method offers acceptable accuracy for analysis of Cr(VI). The method was successfully applied for extraction and determination of Cr(VI) selectively in some tannery waste water samples.  相似文献   

5.
Stable monomeric molybdate(VI) anion-doped polypyrrole composites [Ppy(Mo)] have been prepared from sulfuric acid solution containing Mo(VI) by an electrochemical potential cycling method. Ppy(Mo) films exhibit redox waves inherent to the polypyrrole moiety only, and the built-in Mo(OH)5O is found to be electroinactive. X-ray photoelectron spectroscopic examination of oxidised and reduced Ppy(Mo) films confirms this phenomenon. Received: 5 January 1998 / Accepted: 10 January 1999  相似文献   

6.
An optical sensor is described for the sensitive and selective determination of the Cr(VI) ion in aqueous solutions. The optode membrane is prepared by incorporating Aliquat 336 as an ionophore and a chromoionophore (4',5'-dibromofluorescein octadecyl ester) in a poly(vinyl chloride) (PVC) membrane containing ortho-nitrophenyloctyl ether (o-NPOE) as a plasticizer. The response to Cr(VI) is indicated by co-extraction of the target species and of hydrogen ions into the bulk of the membrane yielding large absorbance changes which can easily be measured in the visible spectral range. The optode membrane shows a reversible response in the concentration range of 1.1x10(-5)-1.0x10(-3) M and has been shown to be more selective towards the HCrO4(-) ion than other anions with a selectivity pattern HCrO4(-) > SCN- approximately = ClO4(-) > NO3(-) approximately = I- approximately = NO2(-) > H2PO4(-) approximately = Cl- approximately = SO4(2-). The sensing method developed has successfully been applied to the determination of Cr(VI) in spiked river water as well as in electroplating rinse waters.  相似文献   

7.
A voltammetric procedure in the flow system for determination of traces of Cr(VI) in the presence of Cr(III) and humic acid is presented. The calibration graph is linear from 5×10−10 to 1×10−7 mol l−1 for an accumulation time of 120 s. The R.S.D. for 1×10−8 mol l−1 Cr(VI) is 5.3% (n=5). The detection limit estimated from 3σ for a low concentration of Cr(VI) and accumulation time of 120 s is 2×10−10 mol l−1. The method can be used for Cr(VI) determination in the presence of up to 50 mg l−1 of humic acid. The validation of the method was carried out by studying the recovery of Cr(VI) from spiked river water and by the comparison of the results of determination of Cr(VI) in a soil sample. The method cannot be used for analysis of samples containing high concentrations of chloride ions such as seawater and estuarine water.  相似文献   

8.
A simple and rapid approach for the electrochemical synthesis of Ag nanoparticles-coated gold nanoporous film (AgGNF) on a gold substrate was reported. The solid gold electrode (SGE) was directly anodized under a high potential of 5 V, and then reduced to obtain gold nanoporous film (AuNF) by freshly prepared ascorbic acid. The Ag nanoparticles (AgNPs) were grown on the AuNF electrode by potential-step electrodeposition. The resulting AgGNF composites electrodes were characterized by scanning electron micro...  相似文献   

9.
The metal anions of vanadium (V) and chromium (VI) in aqueous solution can be effectively adsorbed by Zr(IV)-impregnated collagen fiber (ZrICF). The maximum adsorption capacity of V(V) takes place within the pH range of 5.0 to 8.0, while that of Cr(VI) is within the pH range of 6.0 to 9.0. When the initial concentration of metal ions was 2.00 mmol L−1 and the temperature was 303 K, the adsorption capacity of V(V) on Zr-ICF was 1.92 mmol g−1 at pH 5.0, and the adsorption capacity of Cr(VI) was 0.53 mmol g−1 at pH 7.0. As temperature increased, the adsorption capacity of V(V) increased, while that of Cr(VI) was almost unchanged. The adsorption isotherms of the anionic species of V(V) and Cr(VI) can be fit by the Langmuir equation. The adsorption rate of V(V) follows the pseudo-first-order rate model, while the adsorption rate of Cr(VI) follows the pseudo-second-order rate model. Furthermore, ZrICF shows high adsorption selectivity to V(V) in the mixture solution of V(V) and Cr(VI). Practical applications of ZrICF could be expected in consideration of its performance in adsorption of V(V) and Cr(VI).  相似文献   

10.
Xiang Y  Mei L  Li N  Tong A 《Analytica chimica acta》2007,581(1):132-136
A new fluorogenic method for the selective and sensitive determination of chromium(VI) in acidic water using rhodamine B hydrazide was developed. This method was based on the oxidation of non-fluorescent rhodamine B hydrazide by potassium dichromate in acidic aqueous conditions to give rhodamine B, which was highly fluorescent, as a product. With the optimum condition described, the fluorescence enhancement at 585 nm was linearly related to the concentration of chromium(VI) in the range of 5.0 × 10−8 to 2.0 × 10−6 mol L−1 (2.60-104 ng mL−1) with a correlation coefficient of R2 = 0.9993 (n = 18) and a detection limit of 5.5 × 10−9 mol L−1 (0.29 ng mL−1). The R.S.D. was 2.2% (n = 5). The proposed method was also applied to the determination of chromium(VI) in drinking water, river water and synthetic samples.  相似文献   

11.
12.
Both the accumulation of coal gangue and potentially toxic elements in aqueous solution have caused biological damage to the surrounding ecosystem of the Huainan coal mining field. In this study, coal gangue was used to synthesize calcium silicate hydrate (C-S-H) to remove Cr(VI) and Cu(II)from aqueous solutions and aqueous solution. The optimum parameters for C-S-H synthesis were 700 °C for 1 h and a Ca/Si molar ratio of 1.0. Quantitative sorption analysis was done at variable temperature, C-S-H dosages, solution pH, initial concentrations of metals, and reaction time. The solution pH was precisely controlled by a pH meter. The adsorption temperature was controlled by a thermostatic gas bath oscillator. The error of solution temperature was controlled at ± 0.3, compared with the adsorption temperature. For Cr(VI) and Cu(II), the optimum initial concentration, temperature, and reaction time were 200 mg/L, 40 °C and 90 min, pH 2 and 0.1 g C-S-H for Cr(VI), pH 6 and 0.07 g C-S-H for Cu(II), respectively. The maximum adsorption capacities of Cr(VI) and Cu(II) were 68.03 and 70.42 mg·g−1, respectively. Furthermore, the concentrations of Cu(II) and Cr(VI) in aqueous solution could meet the surface water quality standards in China. The adsorption mechanism of Cu(II) and Cr(VI) onto C-S-H were reduction, electrostatic interaction, chelation interaction, and surface complexation. It was found that C-S-H is an environmentally friendly adsorbent for effective removal of metals from aqueous solution through different mechanisms.  相似文献   

13.
In this study, a tetramine-substituted calix[4]arene derivative, which was synthesised from calix[4]arene by treatment with dimethylamine in one step via Mannich reaction, was used to fabricate a new calix[4]arene-embedded polysulphone membrane (calix@membrane). Its structure and surface morphology were determined using thermogravimetric analysis and scanning electron microscopy, and elemental analysis techniques. Moreover, a Donnan dialysis system was employed to investigate Cr(VI) transport efficacy of calix@membrane at different pH values. Results showed that calix@membrane represented a promising transport capability for HCr2O7? due to their efficient complexation behaviour.  相似文献   

14.
This study describes the use of banana peel, a commonly produced fruit waste, for the removal of Cr(VI) from industrial wastewater. The parameters pH, contact time, initial metal ion concentration, and temperature were investigated and the conditions resulting in rapid and efficient adsorption (95% within 10 min) were determined. The binding of metal ions was found to be pH dependent with the optimal sorption occurring at pH 2. The retained species were eluted with 5 mL of 2 M H2SO4. To elucidate the mechanism of the process, total amounts of chromium and Cr(VI) were analyzed using flame atomic absorption and ultraviolet–visible (UV–vis) spectroscopic techniques, respectively. The Langmuir and Dubinin–Radushkevich (D–R) isotherms were used to describe the partitioning behavior for the system at different temperatures. Kinetics and thermodynamics of Cr(VI) removal by banana peel were also studied. The influence of diverse ions on the sorption behavior revealed that only Fe(II) ions (of those tested) suppressed the sorption of Cr(VI) ions to some extent. The method was applied for the removal of Cr(VI) from industrial wastewater.  相似文献   

15.
Speciation of Cr(III) and Cr(VI) can be attained by flow injection analysis with amperometric detection. Cr(VI) is reduced in an acidic medium to Cr(III) with a glassy carbon electrode at —0.1 V vs. Ag/AgCl and the current is recorded. Cr(III) is oxidised on-line to Cr(VI) with alkaline hydrogen peroxide solution. From the difference of the total chromium and Cr(VI), the amount of Cr(III) was obtained. A linear calibration curve for Cr(VI) was obtained for the concentration ranges 0.01-5.0ppm of Cr(VI) and we have calculated the limit of determination to be about 0.5ppb. We have studied the degree of reproducibility obtained using the solid electrodes under various conditions. The influence of flow rate, coil length, interfenences and the extent of reaction were studied.  相似文献   

16.
A new sensitive chemiluminescence (CL) method combined with continuous flow injection analysis is described for the determination of Cr(VI). Strong CL signals were generated by Cr(VI)-catalysed oxidation of gallic acid in the presence of potassium permanganate and hydrogen peroxide. Effects of reagent concentrations, temperature, pH, flow rates, mixing coil length and mixing flow sequences on the chemiluminescence intensity were studied. Under the optimised experimental conditions, the relationship between the logarithm of concentration (log?C) of Cr(VI) and the logarithm of intensity (log?I) is linear over the range of 2?×?10?11 – 5?×?10?4?mol?L?1, with the detection limit (3σ) of 4?×?10?12?mol?L?1. Relative standard deviation of ten measurements of 1?×?10?9?mol?L?1 Cr(VI) is 1.7%. This flow injection analysis (FIA) system proved to be able to analyse up to 40 samples h?1. Effects of various interferences possibly present in the water samples were investigated. Most cations and anions, as well as organic compounds, did not interfere with the determination of Cr(VI) in water samples. The experimental results obtained for chromium in reference materials were also in good agreement with the certified values.  相似文献   

17.
?ükriye Ulubay 《Talanta》2010,80(3):1461-5138
Cu nanoparticles have been electrochemically incorporated polypyrrole film that was used for modification of the glassy carbon electrode surface. The performance of the electrode has been characterized by cyclic voltammetry and atomic force microscopy. The electrode has shown high electrocatalytic activity towards the oxidation of dopamine (DA) and uric acid (UA) simultaneously in a phosphate buffer solution (pH 7.00). The electrocatalytic oxidation currents of UA and DA were found linearly related to concentration over the range 1 × 10−9 to 1 × 10−5 M for UA and 1 × 10−9 to 1 × 10−7 M for DA using DPVs method. The detection limits were determined as 8 × 10−10 M (s/n = 3) for UA and 8.5 × 10−10 M (s/n = 3) for DA at a signal-to-noise ratio of 3.  相似文献   

18.
There is little conclusive evidence of the toxic effects of Cr(III) so far, but Cr(VI) has carcinogenic activity, so the analysis of the chromine ions is very important in environmental research and the quality control of industry products. Usually Cr(III) and Cr(VI) interfere with each other in the species analysis, the measurement of Cr(VI) of numerous previous papers is related to the Cr(VI) samples, which contain a little Cr(III). When the amount of trivalent chromine exceeds ten …  相似文献   

19.
A rapid, sensitive and selective procedure for determination of Cr(III) and Cr(VI) in environmental and industrial liquid samples via preconcentration with ammonium pyrrolidine dithiocarbamate (APDC) and determination by means of the EDXRF was described. The effect of pH in the range of 3-11 on the recovery of Cr(III) and Cr(VI) has been investigated separately and in combination of these two species. The influence of organic matter, carbonate species and elements V, Mn and Fe on the recovery of each chromium specie (separately/in combination) over whole pH range was also tested in order to simulate condition occurring in natural waters that usually contain certain amount of dissolved organic matter and carbonate ions. Cr(VI) and Cr(III) have shown different behaviors in reaction with APDC at different pH ranges and therefore it is possible to separate those two species. It was found that Cr(VI) creates complex with APDC only in the pH range from 3 to 5 with quantitative recovery (app. 98%) at pH 3, but there was no recovery of Cr(III) at that pH. On the contrary, in pH range from 6 to 11, reaction with Cr(III) and APDC reviled that the only reaction product is Cr(OH)3 instead of the expected Cr(III)-APDC complex. All reaction products were characterized by IR spectroscopy.  相似文献   

20.
The rapid and reliable detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) seroconversion in humans is crucial for suitable infection control. In this sense, many studies have focused on increasing the sensibility, lowering the detection limits and minimizing false negative/positive results. Thus, biosensors based on nanoarchitectures of conducting polymers are promising alternatives to more traditional materials since they can hold improved surface area, higher electrical conductivity and electrochemical activity. In this work, we reported the analytical comparison of two different conducting polymers morphologies for the development of an impedimetric biosensor to monitor SARS-CoV-2 seroconversion in humans. Biosensors based on polypyrrole (PPy), synthesized in both globular and nanotubular (NT) morphology, and gold nanoparticles are reported, using a self-assembly monolayer of 3-mercaptopropionic acid and covalently linked SARS-CoV-2 Nucleocapsid protein. First, the novel hybrid materials were characterized by electron microscopy and electrochemical measurements, and the biosensor step-by-step construction was characterized by electrochemical and spectroscopic techniques. As a proof of concept, the biosensor was used for the impedimetric detection of anti-SARS-CoV-2 Nucleocapsid protein monoclonal antibodies. The results showed a linear response for different antibody concentrations, good sensibility and possibility to quantify 7.442 and 0.4 ng/mL of monoclonal antibody for PPy in the globular and NT morphology, respectively. The PPy-NTs biosensor was able to discriminate serum obtained from COVID-19 positive versus negative clinical samples and is a promising tool for COVID-19 immunodiagnostic, which can contribute to further studies concerning rapid, efficient, and reliable detections.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号