首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A multi-class method for the simultaneous quantification and confirmation of 47 pharmaceuticals in environmental and wastewater samples has been developed. The target list of analytes included analgesic and anti-inflammatories, cholesterol lowering statin drugs and lipid regulators, antidepressants, anti-ulcer agents, psychiatric drugs, ansiolitics, cardiovasculars and a high number (26) of antibiotics from different chemical groups. A common pre-concentration step based on solid-phase extraction with Oasis HLB cartridges was applied, followed by ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) measurement. All compounds were satisfactorily determined in just one single injection, with a chromatographic run time of only 10 min. The process efficiency (combination of the matrix effect and the extraction process recovery) for the 47 selected compounds was evaluated in nine effluent wastewater (EWW) samples, and the use of different isotope-labelled internal standards (ILIS) was investigated to correct unsatisfactory values. Up to 12 ILIS were evaluated in EWW and surface water (SW). As expected, the ILIS provided satisfactory correction for their own analytes. However, the use of these ILIS for the rest of pharmaceuticals was problematic in some cases. Despite this fact, the correction with analogues ILIS was found useful for most of analytes in EWW, while was not strictly required in the SW tested. The method was successfully validated in SW and EWW at low concentration levels, as expected for pharmaceuticals in these matrices (0.025, 0.1 and 0.5 μg/L in SW; 0.1 and 0.5 μg/L in EWW). With only a few exceptions, the instrumental limits of detection varied between 0.1 and 8 pg. The limits of quantification were estimated from sample chromatograms at the lowest spiked levels tested and normally were below 20 ng/L for SW and below 50 ng/L for EWW. The developed method was applied to the analysis of around forty water samples (river waters and effluent wastewaters) from the Spanish Mediterranean region. Almost all the pharmaceuticals selected in this work were detected, mainly in effluent wastewater. In both matrices, analgesics and anti-inflammatories, lipid regulators and quinolone antibiotics were the most detected groups.  相似文献   

2.
A multi-residue analytical method based on high-performance liquid chromatographic separation, electrospray ionization with tandem mass spectrometric detection (HPLC/MS–MS) was developed for the simultaneous analysis of 46 basic, neutral and acidic compounds covering a wide range of polarity (log KOW < 0–5.9). The compound list included selected iodinated contrast media, analgesics, anti-inflammatories, stimulants, beta-blockers, antibiotics, lipid regulators, anti-histamines, psychiatric drugs, herbicides, corrosion inhibitors and the gastric acid regulator pantoprazole. The main feature of the presented method was a simultaneous solid phase extraction (SPE) of all analytes followed by simultaneous separation and detection by HPLC/MS–MS with electrospray ionization in both positive and negative polarization within the same chromatogram. Optimization of electrospray drying gas temperature resulted in using a temperature gradient on the ion source. Six different polymeric sorbents for SPE were compared with respect to recoveries, taking into account the specific surface of each sorbent. Method quantitation limits (MQL) in surface and seawater ranged from 1.2 to 28 ng/L, in wastewater from 5.0 to 160 ng/L, respectively. In order to demonstrate the applicability of the method, river water, treated wastewater and seawater were analyzed.  相似文献   

3.
An improved analytical method for determination of human pharmaceuticals in natural and wastewaters with ng L−1 sensitivity is presented. The method is applicable to pharmaceuticals from a wide range of therapeutic classes including antibiotics, analgesics, anti-inflammatories and anti-cancer compounds. Pharmaceuticals were extracted from waters using solid-phase extraction, and after concentration, analysed by high performance liquid chromatography with tandem mass spectrometric detection (HPLC-MS/MS). Identification of each compound was secured using retention time and by the selected reaction monitoring of two transitions, one of which was additionally used for quantification. Limits of detection ranged from 0.03 to 0.96 ng L−1 and were up to two orders of magnitude lower than those of previously published methods. The method was validated using spiked samples prepared from tap, river and sea water as well as wastewater effluents, collected from the North of Scotland. Analysis of wastewater effluents revealed the presence of mefenamic acid, ibuprofen, erythromycin, diclofenac and trimethoprim. None of the selected pharmaceuticals were detected in river, tap or sea water samples.  相似文献   

4.
This paper describes a method for determining 11 pharmaceuticals in various water sources by SPE followed by LC-(ESI) MS. SPE was carried out with Oasis HLB and the recoveries were 33-67% for 250 and 100 mL sewage water, 55-77% for 500 mL river water and 72-98% for 1 L tap water, with the exception of sulfamethoxazole and omeprazole which showed lower recoveries in all kinds of sample. The LODs in river water were of 5 ng/L for sulfadiazine, trimethoprim, sulfamethazine, sulfamethoxazole, and ranitidine and 10 ng/L for the other compounds. The highest concentrations found in river waters were for sulfamethoxazole (50 ng/L). In influent sewage waters, ranitidine was the most commonly detected compound with a maximum value of 0.24 microg/L.  相似文献   

5.
A new method based on ultra-performance liquid chromatography (UPLC) quadrupole time-of-flight mass spectrometry ((Q-ToF)-MS) was developed for the analysis of 32 biologically active compounds including anti-inflammatories, analgesics, lipid regulators, psychiatric drugs, anti-ulcer agents, antibiotics, beta-blockers and phytoestrogens. This new method allows chromatographic analysis in 14 min, with instrumental detection limits from 2 to 84 pg, and limits of quantification ranging from 0.1 to 15 ng/L in tap water, and from 2 to 300 ng/L in wastewater. The potential of liquid chromatography with triple quadrupole mass spectrometry (LC/QqQ-MS) was compared with that of UPLC/(Q-ToF)-MS for the analysis of biologically active compounds in water samples. LC/Q-ToF provides accurate mass information and a significantly higher mass resolution than quadrupole analyzers. The available mass resolution of ToF instruments diminishes the problem of isobaric interferences and helps the analysis of trace compounds in complex samples. In this work UPLC/Q-ToF chromatograms were recorded containing full scan spectral data. The m/z values of analytes were extracted from the total ion chromatogram (TIC) and the accurate masses of the compounds were obtained. In addition, to increase the selectivity of ToF measurements a narrow accurate mass interval (20 m m/z units mass window) was used to reconstruct the chromatographic traces. However, regarding quantitative performance in terms of dynamic range and limits of detection (LODs), typical LODs achieved by QqQ instruments operating in multiple-reaction monitoring (MRM) mode ranged from 1 to 50 ng/L in wastewater, and the linear response for QqQ instruments generally covers three orders of magnitude. This is an important advantage over ToF instruments and one of the reasons why QqQ instruments are widely used in quantitative environmental analysis.  相似文献   

6.
The LC-MS/MS analysis of a group of 14 organic pollutants in wastewater – including pharmaceuticals (analgesics/anti-inflammatories, lipid regulators and diuretics), pesticides (diuron) and disinfectants (chlorophene) – has been carried out using a hybrid triple quadrupole-linear ion trap-mass spectrometer (QqLIT). In order to take advantage of the capabilities of the QqLIT system, two methods have been developed and compared, based on the application of different operation modes. One of them uses selected reaction monitoring (SRM), which is the standard mode for quantitative LC-MS/MS analysis. The other is based on the use of an information dependent acquisition scan function (IDA), which allows the combination of a SRM acting as the survey scan and an enhanced product ion scan (EPI) as dependent scan within the same analysis. Performance of both methods was compared, especially in terms of their limits of detection and identification capability. The advantages and limitations of both techniques are discussed. Finally, the two methodologies developed were applied to real samples for evaluation of effluent wastewater in a treatment plant on the south-eastern Mediterranean coast of Spain. The presence of most of the target compounds was detected at mean concentrations ranging from 50 ng/L (mefenamic acid) to 3373 ng/L (hydrochlorothiazide).  相似文献   

7.
In this study we developed a GC–MS method for the analysis of priority pollutants, personal care products (PCPs) and other emerging contaminants in waters using large volume injection with backflushing. Analyses are performed in the SIM/scan mode, so that in addition to the targeted organic contaminants, this method allows the simultaneous screening of non-target compounds. The scan data are analysed using Deconvolution Reporting Software (DRS) which screens the results for 934 organic contaminants. Deconvolution helps identify contaminants that are buried in the chromatogram by co-extracted materials and significantly reduces chromatographic resolution requirements, allowing shorter analysis times. All compounds have locked retention times and we can continually update and extend the mass spectral library including new compounds. Linearity and limits of detection in SIM and full-scan mode were studied. Method detection limits (MDLs) in effluent wastewater ranged in most of the cases from 1 to 36 ng/L in SIM mode and from 4 to 66 ng/L in full-scan mode; while in river water from 0.4 to 14 and 2–29 ng/L in SIM and full-scan mode, respectively. We obtained a linearity of the calibration curves over two orders of magnitude. The method has been applied to the screening of a large number of organic contaminants – not only to a subset of targets – in urban wastewaters from different wastewater treatment plants and also in river waters. Most of the target compounds were detected at concentration levels ranging from 11 to 8697 ng/L and from 7 to 1861 ng/L in effluent wastewater and river waters, respectively. Additionally, a group of 12 new compounds were automatically identified using the AMDIS and NIST libraries. Other compounds, such as the 4-amino musk xylene, a synthetic fragrance metabolite, which was not included in the databases, but has been manually searched in the full-scan chromatograms.  相似文献   

8.
A multi-residue analytical method has been developed and validated for determining a selection of 16 pharmaceuticals: the anti-epileptic carbamazepine, seven analgesic/anti-inflammatory drugs (mefenamic acid, indomethacine, ibuprofen, naproxen, diclofenac, ketorolac and acetaminophen), the analgesic opiate codeine, two antidepressants (fluoxetine and paroxetine), beta-blockers (atenolol and propranolol), antibiotic (trimethoprim, metronidazole, and erythromycin) and the anti-ulcer ranitidine in hospital effluent wastewaters. The method allows simultaneous extraction of the pharmaceuticals compounds by solid-phase extraction (SPE) using the Waters Oasis HLB at pH 7. The analytes were then identified and quantitatively determined by liquid chromatography-tandem mass spectrometry (LC-MS-MS) using multiple reaction monitoring (MRM). Recoveries of the pharmaceuticals were higher than 75%, with the exception of ranitidine (45%) and the overall variability of the method was below 9%. The instrumental detection limit (IDL) varied between 2 and 31 pg injected, the method detection limit (LOD) was between 7 and 47 ng/L in spiked hospital effluent. The precision of the method, calculated as relative standard deviation (RSD), ranged from 0.3 to 4.9%. A detail study off matrix effect is included in this work, regarding to signal suppression in these effluent wastewaters from a hospital complex samples. The developed analytical method was applied for preliminary data results in effluent wastewaters from a hospital.  相似文献   

9.
Much attention has recently been devoted to the life and behaviour of pharmaceuticals in the water cycle. In this study the behaviour of several pharmaceutical products in different therapeutic categories (analgesics and anti-inflammatory drugs, lipid regulators, antibiotics, etc.) was monitored during treatment of wastewater in a laboratory-scale membrane bioreactor (MBR). The results were compared with removal in a conventional activated-sludge (CAS) process in a wastewater-treatment facility. The performance of an MBR was monitored for approximately two months to investigate the long-term operational stability of the system and possible effects of solids retention time on the efficiency of removal of target compounds. Pharmaceuticals were, in general, removed to a greater extent by the MBR integrated system than during the CAS process. For most of the compounds investigated the performance of MBR treatment was better (removal rates >80%) and effluent concentrations of, e.g., diclofenac, ketoprofen, ranitidine, gemfibrozil, bezafibrate, pravastatin, and ofloxacin were steadier than for the conventional system. Occasionally removal efficiency was very similar, and high, for both treatments (e.g. for ibuprofen, naproxen, acetaminophen, paroxetine, and hydrochlorothiazide). The antiepileptic drug carbamazepine was the most persistent pharmaceutical and it passed through both the MBR and CAS systems untransformed. Because there was no washout of biomass from the reactor, high-quality effluent in terms of chemical oxygen demand (COD), ammonium content (N-NH4), total suspended solids (TSS), and total organic carbon (TOC) was obtained.  相似文献   

10.
The analysis of pharmaceuticals and potential endocrine disruptors in the environment has rightly concentrated on their presence in wastewaters and possible contamination of receiving bodies, such as groundwaters. However, wastewater is increasingly being reused for irrigation and in order to fully understand the environmental fate of these compounds, reliable methods for their analysis in soil are required, of which there are relatively few available. This article reports a method for a range of acidic pharmaceuticals, carbamazepine, and endocrine disrupting compounds in soils with final analysis by gas chromatography-mass spectrometry. Two soil types (Phaeozom and Leptosol) and three fortification levels were used to validate the method. Recoveries of acidic pharmaceuticals varied between 62 and 102%, carbamazepine from 75 to 118%, and potential endocrine disruptors between 54 and 109%; most recoveries were between 75 and 95% and relative standard deviations were generally less than 10%. Detection limits were between 0.25 and 2.5 ng/g except for phthalates and 4-nonylphenols (25 ng/g). The method was used to analyze soils where untreated wastewaters have been used to irrigate crops for approximately 90 years. Concentrations of acidic pharmaceuticals in the soil were <1 ng/g and potential endocrine disruptors varied from below the limit of detection (estrone, 17β-estradiol, and 17α-ethinylestradiol) to 2079 ng/L (bis-diethylhexyl phthalate). This data indicated that despite the continuous application of the contaminants over many years, concentrations were generally lower than those expected to be contributed by a single irrigation event. Only carbamazepine, at concentrations of 6.48 ng/g (in Phaeozem) and 5.14 ng/g (in Leptosol), showed any evidence of persistence in the soils analyzed.  相似文献   

11.
An in situ derivatization solid-phase microextraction method has been developed for the determination of parabens, triclosan and related chlorophenols in water. Acetylated derivatives are selectively determined using gas chromatography with tandem mass spectrometry. Parameters affecting both derivatization and SPME procedures, such as fiber coating, extraction mode, temperature, volume of derivatizating reagent and ionic strength, are studied and optimized through a multifactorial experimental design. The performance of the method is studied in terms of accuracy, linearity, precision and limits of detection. Quantitative recoveries (≥82%) and satisfactory precision (RSD ≤ 12%) are obtained. Limits of detection at the low picogram per millilitre level are achieved for all target compounds. Linearity is studied in a wide range of concentrations and an analysis of variance with a lack-of-fit test is run to validate the calibration data. Extraction time profiles are also obtained. Finally, the applicability of the proposed method is demonstrated for several real samples including river water, wastewaters and swimming pool water. Since no matrix effects are observed, quantification can readily be carried out by external calibration with ultrapure water standards.  相似文献   

12.
Simultaneous ultrasound-assisted emulsification-microextraction (USAEME) and derivatization combined with gas chromatography-tandem mass spectrometry (GC-MS/MS) is proposed for the first time for the analysis of parabens, triclosan and related phenols in water samples. In situ acetylation was successfully applied for the derivatization of target compounds with high efficiency using non-expensive reagents. The proposed method exhibits many advantages such as simplicity, efficiency, low cost, and minimum solvent consumption. In addition, the whole analytical process, including sample preparation and determination, is performed in only 20 min.A multifactorial experimental design was employed to study and optimize the main variables potentially affecting the microextraction and derivatization processes (extraction solvent, phase ratio, sodium chloride concentration, extraction time, and acetic anhydride volume).The performance of the method was studied in terms of accuracy, linearity, precision, and enrichment factor. Quantitative recoveries (≥85%) were obtained for all target compounds, and method precision was also satisfactory (RSD ≤ 13%) even for complex samples. Enrichment factors ranging from 100 to 200 were obtained, allowing achieving limits of detection at the low picogram per millilitre for most of the target compounds.Several real samples, including wastewaters, river waters and swimming pool water, were analyzed. Since matrix effects were not observed, quantification can easily be performed using external calibration with acetylated standards, allowing a high sample throughput.  相似文献   

13.
We developed a sensitive and useful method for the determination of five fluoroquinolones (FQs), enoxacin, ofloxacin, ciprofloxacin, norfloxacin, and lomefloxacin in environmental waters, using a fully automated method consisting of in-tube solid-phase microextraction (SPME) coupled with liquid chromatography-tandem mass spectrometry (LC/MS/MS). These compounds were analysed within 7 min by high-performance liquid chromatography (HPLC) using a CAPCELL PAK C8 column and aqueous ammonium formate (pH 3.0, 5 mM)/acetonitrile (85/15, v/v) at a flow rate of 0.2 mL/min. Electrospray ionization conditions in the positive ion mode were optimized for MS/MS detection. In order to optimize the extraction of FQs, several in-tube SPME parameters were examined. The optimum in-tube SPME conditions were 20 draw/eject cycles of 40 μL of sample at a flow-rate of 150 μL/min, using a Carboxen 1010 PLOT capillary column as an extraction device. The extracted compounds were easily desorbed from the capillary by passage of the mobile phase. Using the in-tube SPME LC/MS/MS method, good linearity of the calibration curve (r ≥ 0.997) was obtained in the concentration range from 0.1 to 10 ng/mL for all compounds examined. The limits of detection (S/N = 3) of the five FQs ranged from 7 to 29 pg/mL. The in-tube SPME method showed 60-94-fold higher sensitivity than the direct injection method (5 μL injection). This method was applied successfully to the analysis of environmental water samples without any other pretreatment and interference peaks. Several surface waters and wastewaters were collected from the area around Asahi River, and ofloxacin was detected in wastewater samples of a sewage treatment plant and other two hospitals at 17.5-186.2 pg/mL. The recoveries of FQs spiked into river water were above 81% for a 0.1 or 0.2 ng/mL spiking concentration, and the relative standard deviations were below 1.9-8.6%.  相似文献   

14.
Although there is increasing concern about residues from personal care products entering the aquatic environment and their potential to accumulate to levels that pose a health threat to humans and wildlife, we still know little about the extent and magnitude of their presence in the aquatic environment. In this study we describe a procedure for isolation, and subsequent determination, of compounds commonly added to personal care products. The compounds of interest include UV filters with the commercial name Eusolex (homosalate, 4-methylbenzylidenecamphor, benzophenone-3, octocrylene, butylmethoxydibenzoylmethane, ethylhexyl methoxycinnamate) and two common anti-microbial agents, clorophene and triclosan. Water samples were filtered, acidified, and extracted by use of solid-phase extraction. Extracted compounds were then derivatised before analysis by gas chromatography–mass spectroscopy. By use of our method we obtained limits of detection of 13–266 ng L−1 for UV filters, and 10–186 ng L−1 for triclosan and clorophene. Recoveries were 82–98% for deionised water and 50–98% for natural water (seawater, pool water, lake water, and river water). Samples collected in Slovenia included seventeen recreational waters (seawater, pool water, lake water, and river water; August 2004) and four wastewaters (January 2005). The most abundant UV filter was benzophenone-3 (11–400 ng L−1). Of the two anti-microbial agents studied, trace amounts, only, of triclosan were present in the river Kolpa (68 ng L−1) and in an hospital effluent (122 ng L−1).  相似文献   

15.
In this study we have developed and evaluated an analytical method for a rapid automated screening and confirmation of a large number of organic micro-contaminants (almost 400) and also the quantification of the positive findings in water samples of different types (surface and wastewaters) using liquid chromatography-electrospray quadrupole-time-of-flight mass spectrometry (LC-QTOFMS) based on the use of an accurate-mass database. The created database includes data not only on the accurate masses of the target ions but also on the characteristic in-source fragment ions, isotopic pattern and retention time data. This customized database was linked to commercially available software which extracted all the potential compounds of interest from the LC-QTOFMS raw data of each sample and matched them against the database to search for targeted compounds in the sample. The detailed fragmentation information has also been used as a powerful tool for the automatic identification of unknown compounds and/or transformation products with similar structures to those of known organic contaminants included in the database. The database can be continually enlarged. To confirm identification of compounds which have no fragment ions (or fragments with low intensity/relative abundance) from in-source CID fragmentation or isomers which are not distinguished within full single mass spectra, a "Targeted MS/MS" method is developed. Thereafter, these compounds can be further analyzed using the collision energy (CE) in QTOF-MS/MS mode. Linearity and limits of detection were studied. Method detection limits (MDLs) in effluent wastewater and river waters were, in most cases, lowers or equal to 5 and 2 ng/L, respectively. Only 15 compounds had MDLs between 5 and 50 ng/L in effluent wastewater matrix. We obtained a linearity of the calibration curves over two orders of magnitude. The method has been applied to real samples and the results obtained reveal that most of the pharmaceutically active compounds contained in the created database were present in the water samples with concentrations in the range of ng/L and μg/L levels and in most of the samples between 2 and 15 pesticides of the 300 contained in the database were also detected. In addition to the compounds included in the database, some degradation products were found, thus revealing the method as a useful tool for the analysis of organic micro-contaminants in waters.  相似文献   

16.
Azzouz A  Souhail B  Ballesteros E 《Talanta》2011,84(3):820-828
A sensitive, reliable method using continuous solid-phase extraction and gas chromatography-mass spectrometry was developed for the simultaneous determination of twenty pharmaceuticals including antibacterials, anti-epileptics, antiseptics, β-blockers, lipid regulators, hormones and non-steroidal anti-inflammatories at trace levels in edible animal tissues. The procedure involves deproteination and delipidation of samples by precipitation/centrifugation/filtration, followed by sample enrichment and cleanup by continuous solid-phase extraction. The proposed method was validated with quite good analytical results including low limits of detections (0.4-2.7 ng kg−1 for 2 g of sample) and good linearity (r2 > 0.995) throughout the studied concentration ranges. In addition, the method is quite accurate (recoveries ranged from 92 to 101%) and precise (within-day and between-day RSD values were less than 7%), which allows the determination of residual pharmaceuticals in tissues from agricultural farm and fish hatchery animals (pig, veal, lamb and chicken muscle, kidney and liver; and salmon, sea bass and sole flesh). The analytes most frequently found in the studied samples were the hormones estrone and 17β-estradiol, and the antibacterials florfenicol and pyrimethamine.  相似文献   

17.
The occurrence and seasonal distribution of 14 pharmaceutical substances of different classes were investigated in two drinking water treatment plants (DWTPs) supplied by the two main Italian rivers, the Po and the Adige (Northern Italy). The therapeutic categories of the selected pharmaceuticals included anti-inflammatory drugs, β-blockers, lipid regulators, diuretics, anti-epileptics, antibiotics and a steroidal hormone. The named compounds were assessed in samples collected from the river water inlet and after each purification stage (sand filtration, ozone treatment, granular active carbon (GAC)). Six of the 14 selected pharmaceuticals were found in all analysed samples, with concentration levels ranging from 1?ng?l?1 for atorvastatin to 69?ng?l?1 for atenolol in the drinking water produced. The granular active carbon stage resulted the most efficient in eliminating the examined chemicals from the water (removal range: 12–95%, average: 68%), while the sand filtration stage resulted the least effective treatment (removal range: 4–37%, average: 13%). The observed differences between winter and summer conditions, in terms of residual concentrations and number of detected analytes, seemed to depend mainly on the quality of the river water supplies. To the best of our knowledge, these are the first reported data on the presence of pharmaceuticals in drinking water obtained from the water treatment of these two rivers.  相似文献   

18.
In this work, we optimize a solid phase microextraction (SPME) method for the simultaneous collection of antibiotics (sulfonamides, macrolides, and trimethoprim) present in wastewaters. The performance of the SPME method is compared to a solid phase extraction (SPE) method. Analytes in both cases were quantified by high performance liquid chromatography-tandem mass spectrometry (HPLC-MS-MS) with electrospray ionization. The advantages offered by SPME in this application are: decreased sample volume requirements, ease of sample processing and extraction, decreased cost, and most importantly, elimination of electrospray matrix effects. Despite having higher limits of quantification (16-1380 ng/L in influent and 35-260 ng/L in effluent), nearly all of the compounds found to be present in Edmonton Gold Bar wastewater by SPE were measurable by SPME (i.e., sulfamethoxazole, trimethoprim, erythromycin, and clarithromycin), with values similar to those obtained using the former method. Limits of quantification for the SPE method for the measured compounds were 4.7-15 ng/L and 0.86-6.1 ng/L for influent and effluent, respectively.  相似文献   

19.
An analytical method for the simultaneous determination of nine β-blockers (sotalol atenolol, nadolol, pindolol, metoprolol, timolol, bisoprolol, propanolol and betaxolol) and two analgesics (paracetamol and phenazone) in river water by liquid chromatography and diode array detection is reported. The method involves a modified precolumn switching methodology replacing the small precolumn with a short C18 liquid chromatography column (50 mm × 4.6 mm, 5 μm particle size), thus allowing the preconcentration of large water sample volumes whereas interferences eluting at the first of the chromatogram were discarded to waste. This approach allowed to preconcentrate 30 mL river water samples, modified with 0.4% MeOH, achieving univariate method detection and determination limits ranged between 0.03 and 0.16 μg L−1 and between 0.2 and 0.5 μg L−1, respectively, with precision values lower than 9.4% for spiking levels at the quantitation limits of each analyte and lower than 4.0%, except bisoprolol (8.3%), for higher spiking levels (1.0 μg L−1 of all analytes). Matrix background was reduced in three way data by a baseline correction following the Eilers methodology, whereas multivariate curve resolution and alternating least squares in combination with the standard addition calibration method, applied to these data, coped with overlapping peak, systematic (additive) and proportional (matrix effect) errors. The method was successfully applied for the determination of the target pharmaceuticals in river water from three places in a river stream with acceptable recoveries and precision values, taking into account the complexity of the analytical problem. The joint statistical test for the slope and the intercept of the linear regression between the nominal concentration values versus those predicted, showed that the region computed contained the theoretically expected values (0) for the intercept and (1) for the slope (at a confidence level of 95%), which indicates the absence of both constant and proportional errors in the predicted concentrations.  相似文献   

20.
An analytical method for the simultaneous determination of eight pharmaceutical compounds in biosolids from urban wastewater treatment plants (WWTPs) was developed and validated. The compounds evaluated were non-steroidal anti-inflammatory drugs (naproxen, diclofenac, and ibuprofen), lipid regulators (clofibric acid), and antibiotics (sulfathiazole, sulfapyridine, sulfamethazine, and sulfamethoxazole). Ultrasound assisted extraction with a water–methanol solvent mixture (1:1, v:v) was performed and the compounds were then determined by liquid chromatography coupled with tandem mass spectrometry. The design of the method was based on the application of the standard addition calibration methodology to reduce matrix interferences. Validation procedures were conducted with rabbit excrements as blank samples. Recoveries of the target analytes ranged from 76 to 131% in spiked samples at 50, 200 or 1000 ng g?1 dry weight (dw). The relative standard deviations were in the range of 5–15% and the method detection limits ranged from 2 to 12 ng g?1dw. The method was applied to monitor pharmaceutical concentrations in biosolids from different WWTPs over an eight-month period (May to December 2011). Diclofenac, sulfapyridine and ibuprofen were detected in most of the samples whereas sulfamethazine and ibuprofen were the pharmaceuticals found in the highest concentrations (>200 ng g?1 dw on average).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号