首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Wu Y  Lin JM  Su R  Qu F  Cai Z 《Talanta》2004,64(2):338-344
An end-channel amperometric detector with a guide tube for working electrode was designed and integrated on a home-made glass microchip. The guide tube was directly patterned and fabricated at the end of the detection reservoir, which made the fixation and alignment of working electrode relatively easy. The fabrication was carried out in a two-step etching process. A 30 μm carbon fiber microdisk electrode and Pt cathode were also integrated onto the amperometric detector. The characteristics and primary performance of the home-made microchip capillary electrophoresis (MCCE) were investigated with neurotransmitters. The baseline separation of dopamine (DA), catechol (CA) and epinephrine (EP) was achieved within 80 s. Separation parameters such as injection time, buffer components, pH of the buffer were studied. Relative standard deviations of not more than 6.0% were obtained for both peak currents and migration times. Under the selected separation conditions, the response for DA was linear from 5 to 200 μM and from 20 to 800 μM for CA. The limits of detection of DA and CA were 0.51 and 2.9 μM, respectively (S/N=3).  相似文献   

2.
Liu AL  He FY  Hu YL  Xia XH 《Talanta》2006,68(4):1303-1308
Rapid separation and determination of acetaminophen and its hydrolysate with end-channel electrochemical (EC) detection integrated on a plastified poly(ethylene terephthalate) (PET)-toner microchip capillary electrophoresis (CE) system was investigated. In this separation and detection system, a Pt ultramicroelectrode integrated on a three-dimensional adjustor was used as working electrode. Factors influencing the separation and detection were investigated and optimized. Results show that acetaminophen and p-aminophenol can be well separated within 84 s with R.S.D. < 1% for migration time and R.S.D. < 3.6% for detection current for both analytes. Detection limits for both analytes are determined to be 5.0 μM (S/N = 3). This method has been successfully applied to the detection of trace p-aminophenol in paracetamol tablets. The results demonstrate that the PET-toner microchips can obtain better performance than PDMS microfluidic devices but at much lower cost.  相似文献   

3.
Kang J  Yan J  Liu J  Qiu H  Yin XB  Yang X  Wang E 《Talanta》2005,66(4):1018-1024
In this paper a method was described about dynamic coating for resolving rhodamine B (RB) adsorption on a hybrid poly(dimethylsiloxane) (PDMS)/glass chip. The results showed that when the non-ionic surfactant Triton X-100 was higher than 0.5% (v/v) into the phosphate buffer, the adsorption of RB appeared. Besides, some separation conditions for RB were investigated, including concentration of Triton X-100, concentration and pH value of running buffer, separation voltage and detection site. Through comparing electroosmotic flow, plate numbers and other parameters, an acceptable separation condition was obtained. Under optimized conditions, the precisions of RB detection (R.S.D., n = 10) were 2.62% for migration time, 4.78% for peak height respectively. Additionally, RB concentration linearity response was excellent with 0.9996 of correlation coefficient between 1 and 100 μM, and a limit of detection (S/N = 3) was 0.2 μM. Finally, we separated rhodamine B isothiocyanate and lysine deriving from the fluorescent probe, and the result displayed that the dynamic coating method was applicable by CE separations using PDMS/glass chip.  相似文献   

4.
In-channel indirect amperometric detection mode for microchip capillary electrophoresis with positive separation electric field is successfully applied to some heavy metal ions. The influences of separation voltage, detection potential, the concentration and pH value of running buffer on the response of the detector have been investigated. An optimized condition of 1200 V separation voltage, −0.1 V detection potential, 20 mM (pH 4.46) running buffer of 2-(N-morpholino)ethanesulfonic acid (MES) + l-histidine (l-His) was selected. The results clearly showed that Pb2+, Cd2+, and Cu2+ were efficiently separated within 80 s in a 3.7 cm long native separation PDMS/PDMS channel and successfully detected at a single carbon fibre electrode. The theoretical plate numbers of Pb2+, Cd2+, and Cu2+ were 1.2 × 105, 2.5 × 105, and 1.9 × 105 m−1, respectively. The detection limits for Pb2+, Cd2+, and Cu2+ were 1.3, 3.3 and 7.4 μM (S/N = 3).  相似文献   

5.
Palraj Kalimuthu 《Talanta》2010,80(5):1686-319
This paper describes the simultaneous determination of ascorbic acid (AA), dopamine (DA), uric acid (UA) and xanthine (XN) using an ultrathin electropolymerized film of 2-amino-1,3,4-thiadiazole (p-ATD) modified glassy carbon (GC) electrode in 0.20 M phosphate buffer solution (pH 5.0). Bare GC electrode failed to resolve the voltammetric signals of AA, DA, UA and XN in a mixture. On the other hand, the p-ATD modified electrode separated the voltammetric signals of AA, DA, UA and XN with potential differences of 110, 152 and 392 mV between AA-DA, DA-UA and UA-XN, respectively and also enhanced their oxidation peak currents. The modified electrode could sense 5 μM DA and 10 μM each UA and XN even in the presence of 200 μM AA. The oxidation currents were increased from 30 to 300 μM for AA, 5 to 50 μM for DA and 10 to 100 μM for each UA and XN, and the lowest detection limit was found to be 2.01, 0.33, 0.19 and 0.59 μM for AA, DA, UA and XN, respectively (S/N = 3). The practical application of the present modified electrode was demonstrated by the determination of AA, UA and XN in human urine samples.  相似文献   

6.
In this paper, glucose oxidase (GOx) was employed to construct a functional film on the poly(dimethylsiloxane) (PDMS) microfluidic channel surface and apply to perform electrophoresis coupled with in‐channel electrochemical detection. The film was formed by sequentially immobilizing poly(diallyldimethylammonium chloride) (PDDA) and GOx to the microfluidic channel surface via layer‐by‐layer (LBL) assembly. A group of neurotransmitters (5‐hydroxytryptamine, 5‐HT; dopamine, DA; epinephrine, EP; dobuamine, DBA) as a group of separation model was used to evaluate the effect of the functional PDMS microfluidic devices. Electroosmotic flow (EOF) in the modified PDMS microchannel was well suppressed compared with that in the native one. Experimental conditions were optimized in detail. As expected, these analytes were efficiently separated within 110 s in a 3.7 cm long separation channel and successfully detected at a single carbon fiber electrode. Good performances were attributed to the decreased EOF and the interactions of analytes with the immobilized GOx on the PDMS surface. The theoretical plate numbers were 2.19×105, 1.89×105, 1.76×105, and 1.51×105 N/m at the separation voltage of 1000 V with the detection limits of 1.6, 2.0, 2.5 and 6.8 μM (S/N=3) for DA, 5‐HT, EP and DBA, respectively. In addition, the modified PDMS channels had long‐term stability and excellent reproducibility.  相似文献   

7.
In the present work, chemiluminescence detection was integrated with capillary electrophoresis microchip. The microchip was designed on the principle of flow-injection chemiluminescence system and capillary electrophoresis. It has three main channels, five reservoirs and a detection cell. As model samples, dopamine and catechol were separated and detected using a permanganate chemiluminescent system on the prepared microchip. The samples were electrokinetically injected into the double-T cross section, separated in the separation channel, and then oxidized by chemiluminescent reagent delivered by a home-made micropump to produce light in the detection cell. The electroosmotic flow could be smoothly coupled with the micropump flow. The detection limits for dopamine and catechol were 20.0 and 10.0 μM, respectively. Successful separation and detection of dopamine and catechol demonstrated the distinct advantages of integration of chemiluminescent detection on a microchip for rapid and sensitive analysis.  相似文献   

8.
A simple method to fabricate cylindrical carbon electrodes for use in capillary electrophoresis (CE) microchips is described. The electrodes were fabricated using a metallic wire coated with carbon ink. Several experimental variables were studied in order to establish the best conditions to fabricate the electrode. Finally, the electrodes were integrated in a poly(dimethylsiloxane) microchip and used for the analysis of phenolic compounds. Using the optimum conditions, the analysis of a mixture of dopamine, epinephrine, catechol, and 4-aminophenol was achieved in less than 240 s, showing good linear responses (R2 = 0.999) in the 0.1-190 μM range, and limits of detection (without the use of stacking or a decoupler) of 140 and 105 nM for dopamine and epinephrine, respectively.  相似文献   

9.
A new, simple method was reported to prepare PDMS membranes with micrometer size pores for microfluidic chip applications. The pores were formed by adding polystyrene and toluene into PDMS prepolymer solution prior to spin-coating and curing. The resulting PDMS membrane has a thickness of around 10 μm and macropores with a diameter ranging from 1 to 2 μm measured using scanning electron microscope (SEM) imaging. This PDMS membrane was validated by integrating it with PDMS microfluidic chips for protein separation using isoelectric focusing mechanism coupled with whole channel imaging detection (IEF-WCID). It has been shown that five standard pI markers and a mixture of two proteins, myoglobin and β-lactoglobulin, can be separated using these chips. The results indicated that this macroporous PDMS membrane can replace the dialysis membrane in PDMS chips for the IEF-WCID technique. The preparation method of macroporous PDMS membrane may be potentially applied in other fields of microfluidic chips.  相似文献   

10.
A novel electrode was developed through electrodepositing gold nanoparticles (GNPs) on overoxidized-polyimidazole (PImox) film modified glassy carbon electrode (GCE). The combination of GNPs and the PImox film endowed the GNPs/PImox/GCE with good biological compatibility, high selectivity and sensitivity and excellent electrochemical catalytic activities towards ascorbic acid (AA), dopamine (DA), uric acid (UA) and tryptophan (Trp). In the fourfold co-existence system, the peak separations between AA–DA, DA–UA and UA–Trp were large up to 186, 165 and 285 mV, respectively. The calibration curves for AA, DA and UA were obtained in the range of 210.0–1010.0 μM, 5.0–268.0 μM and 6.0–486.0 μM with detection limits (S/N = 3) of 2.0 μM, 0.08 μM and 0.5 μM, respectively. Two linear calibrations for Trp were obtained over ranges of 3.0–34.0 μM and 84.0–464.0 μM with detection limit (S/N = 3) of 0.7 μM. In addition, the modified electrode was applied to detect AA, DA, UA and Trp in samples using standard addition method with satisfactory results.  相似文献   

11.
A method based on capillary electrophoresis with electrochemical detection has been developed for the separation and determination of mannitol, sucrose, glucose, and fructose in Ligustrum lucidum Ait. for the first time. Effects of several important factors such as the concentration of NaOH, separation voltage, injection time, and detection potential were investigated to acquire the optimum conditions. The detection electrode was a 300 μm diameter copper disc electrode at a working potential of +0.65 V (versus saturated calomel electrode (SCE)). The four analytes can be well separated within 13 min in a 40 cm length fused-silica capillary at a separation voltage of 12 kV in a 75 mM NaOH aqueous solution. The relation between peak current and analyte concentration was linear over about three orders of magnitude with detection limits (S/N = 3) ranging from 1 to 2 μM for all analytes. The proposed method has been successfully applied to monitor the mannitol and sugar contents in the plant samples at different growth stages with satisfactory assay results.  相似文献   

12.
This report described proteins modification of poly(dimethylsiloxane) (PDMS) microfluidic chip based on layer-by-layer (LBL) assembly technique for enhancing separation efficiency. Two kinds of protein-coated films were prepared. One was obtained by successively immobilizing the cationic polyelectrolyte (chitosan, Chit), gold nanoparticles (GNPs), and protein (albumin, Albu) to the PDMS microfluidic channels surface. The other was achieved by sequentially coating lysozyme (Lys) and Albu. Neurotransmitters (dopamine, DA; epinephrine, EP) and environmental pollutants (p-phenylenediamine, p-PDA; 4-aminophenol, 4-AP; hydroquinone, HQ) as two groups of separation models were studied to evaluate the effect of the functional PDMS microfluidic chips. The results clearly showed these analytes were efficiently separated within 140 s in a 3.7 cm long separation channel and successfully detected with in-channel amperometric detection mode. Experimental parameters in two protocols were optimized in detail. The detection limits of DA, EP, p-PDA, 4-AP, and HQ were 2.0, 4.7, 8.1, 12.3, and 14.8 microM (S/N=3) on the Chit-GNPs-Albu coated PDMS/PDMS microchip, and 1.2, 2.7, 7.2, 9.8, and 12.2 microM (S/N=3) on the Lys-Albu coated one, respectively. In addition, through modification, the more homogenous channel surface displayed higher reproducibility and better stability.  相似文献   

13.
Nanocrystalline graphite-like pyrolytic carbon film (PCF) electrode fabricated by a non-catalytic chemical vapor deposition (CVD) process was used for the simultaneous electrochemical sensing of ascorbic acid (AA), dopamine (DA), and uric acid (UA). The electrode was studied with respect to changes in electrocatalytic activity caused by a simple and fast electrochemical pretreatment. The anodized electrode exhibited excellent performance compared to many chemically modified electrodes in terms of detection limit, linear dynamic range, and sensitivity. Differential pulse voltammetry (DPV) was used for the simultaneous determination of ternary mixtures of DA, AA, and UA. Under optimum conditions, the detection limits were 2.9 μM for AA, 0.04 μM for DA, and 0.03 μM for UA with sensitivities of 0.078, 5.345, and 6.192 A M−1, respectively. The peak separation was 219 mV between AA and DA and 150 mV between DA and UA. No electrode fouling was observed and good reproducibility was obtained in all the experiments. The sensor was successfully applied for the assay of DA in an injectable drug and UA in human urine by using standard addition method.  相似文献   

14.
Yan Xiao 《Talanta》2007,72(4):1316-1321
The separation of three kinds of aminophenol isomers were achieved within 1 min in polyelectrolytes multilayers modified PDMS microchips by layer-by-layer assembly with electrochemical detection (EC). Two polyelectrolytes, poly(dially dimethyl ammonium chloride) (PDDA) and poly(sodium-4-styrene-sulfonate) (PSS) were used to form polyelectrolyte multilayers (PEMs). The surface characteristic of the modified microchip was studied by XPS. The electroosmotic flow (EOF) on PEMs modified PDMS microchips was more stable than that of the native PDMS microchips and the adsorption of samples was greatly reduced on PEMs modified PDMS microchips during the electrophoretic process. The column efficiencies on PEMs modified microchip were increased by 100 times and the signals enhanced by 2 times compared with those of native microchips. The separation conditions such as running buffer pH, running buffer concentration and separation voltage were also optimized.  相似文献   

15.
Chen G  Zhang L  Wang J 《Talanta》2004,64(4):1018-1023
Multi-walled carbon nanotube (CNT) was mixed with epoxy to fabricate microdisc electrode used as a detector for a specially designed miniaturized capillary electrophoresis (CE)-amperometric detection system for the separation and detection of several bioactive thiols. The end-channel CNT amperometric detector offers favourable signal-to-noise characteristics at a relatively low potential (0.8 V) for detecting thiol compounds. Factors influencing the separation and detection processes were examined and optimized. Four thiols (homocysteine, cysteine, glutathione, and N-acetylcysteine) have been separated within 130 s at a separation voltage of 2000 V using a 20 mM phosphate running buffer (pH 7.8). Highly linear response is obtained for homocysteine, cysteine, glutathione, and N-acetylcysteine over the range of 5-50 μM with detection limits of 0.75, 0.8, 2.9, and 3.3 μM, respectively. Good stability and reproducibility (R.S.D. < 5%) are obtained reflecting the minimal adsorption of thiols at the CNT electrode surface. The new microchip protocol should find a wide range of bioanalytical applications involving assays of thiol compounds.  相似文献   

16.
Ruecha N  Siangproh W  Chailapakul O 《Talanta》2011,84(5):1323-1328
In this work, the rapid detection of cholesterol using poly(dimethylsiloxane) microchip capillary electrophoresis, based on the coupling of enzymatic assays and electrochemical detection, was developed. Direct amperometric detection for poly(dimethylsiloxane) (PDMS) microchip capillary electrophoresis was successfully applied to quantify cholesterol levels. Factors influencing the performance of the method (such as the concentration and pH value of buffer electrolyte, concentration of cholesterol oxidase enzyme (ChOx), effect of solvent on the cholesterol solubility, and interferences) were carefully investigated and optimized. The migration time of hydrogen peroxide, product of the reaction, was less than 100 s when using 40 mM phosphate buffer at pH 7.0 as the running buffer, a concentration of 0.68 U/mL of the ChOx, a separation voltage of +1.6 kV, an injection time of 20 s, and a detection potential of +0.5 V. PDMS microchip capillary electrophoresis showed linearity between 38.7 μg/dL (1 μM) and 270.6 mg/dL (7 mM) for the cholesterol standard; the detection limit was determined as 38.7 ng/dL (1 nM). To demonstrate the potential of this assay, the proposed method was applied to quantify cholesterol in bovine serum. The percentages of recoveries were assessed over the range of 98.9-101.8%. The sample throughput was found to be 60 samples per hour. Therefore, PDMS microchip capillary electrophoresis, based on the coupling of enzymatic assays and electrochemical detection, is very rapid, accurate and sensitive method for the determination of cholesterol levels.  相似文献   

17.
In the present work, a tube-like structure of graphene hybrid as modifier to fabricate electrode for simultaneous detection of ascorbic acid (AA), dopamine (DA), uric acid (UA) and tryptophan (Trp) was reported. The hybrid was synthesized by a simple method based on graphene sheets (GS) and 3,4,9,10-perylenetetracarboxylic acid (PTCA) via π–π stacking interaction under ultrasonic condition. The combination of GS and PTCA could effectively improve the dispersion of GS, owing to PTCA with the carboxylic-functionalized interface. Comparing with pure GS or PTCA modified electrode, GS–PTCA displayed high catalytic activity and selectivity toward the oxidation of AA, DA, UA, and Trp. Moreover, cyclic voltammetry, different pulse voltammetry and scanning electron microscopy were employed to characterize the sensors. The experiment results showed that the linear response range for simultaneous detection of AA, DA, UA, and Trp were 20–420 μM, 0.40–374 μM, 4–544 μM and 0.40–138 μM, respectively, and the detection limits were 5.60 μM, 0.13 μM, 0.92 μM and 0.06 μM (S/N = 3). Importantly, the proposed method offers promise for simple, rapid, selective and cost-effective analysis of small biomolecules.  相似文献   

18.
A selective detection method for dopamine (DA) was developed by incorporating cibacron blue (F3GA) into poly-1,5-diaminonaphthalene (PDAN) layer. Scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS), and cyclic voltammetry (CV) were employed to characterize the modified surfaces. The modified electrode was effective in selectively facilitating the electron transfer of DA and blocking the interferences of negatively charged species attributed to the sulfonate groups in the F3GA/PDAN composite film. This method enabled the determination of DA in the presence of various interfering species, including ascorbic acid (AA), in a phosphate buffer solution (pH 7.4). The modified electrode demonstrated good performance in the detection of DA in a concentration range of 5.0-100 μM, with a detection limit (k = 3) of 0.1 ± 0.01 μM. The application was conducted for the determination of DA in a human urine sample and the sensor was proven to be rapid, has excellent selectivity, and stable amperometric response.  相似文献   

19.
A highly sensitive microchip electrophoresis (MCE) method with chemiluminescence (CL) detection was developed for the determination of biogenic amines including agmatine (Agm), epinephrine (E), dopamine (DA), tyramine, and histamine in human urine samples. To achieve a high assay sensitivity, the targeted analytes were pre-column labeled by a CL tagging reagent, N-(4-aminobutyl)-N-ethylisoluminol (ABEI). ABEI-tagged biogenic amines after MCE separation reacted with hydrogen peroxide in the presence of horseradish peroxidase (HRP), producing CL emission. Since no CL reagent was added to the running buffer, the background of the CL detection was extremely low, resulting in a significant improvement in detection sensitivity. Detection limits (S/N = 3) were in the range from 5.9 × 10−8 to 7.7 × 10−8 M for the biogenic amines tested, which were at least 10 times lower than those of the MCE–CL methods previously reported. Separation of a urine sample on a 7 cm glass/poly(dimethylsiloxane) (PDMS) microchip channel was completed within 3 min. Analysis of human urine samples found that the levels of Agm, E and DA were in the ranges of 2.61 × 10−7 to 4.30 × 10−7 M, 0.81 × 10−7 to 1.12 × 10−7 M, and 8.76 × 10−7 to 11.21 × 10−7 M (n = 4), respectively.  相似文献   

20.
For the first time, an electrodeposited nano-scale islands of ruthenium oxide (ruthenium oxide nanoparticles), as an excellent bifunctional electrocatalyst, was successfully used for hydrazine and hydroxylamine electrocatalytic oxidation. The results show that, at the present bifunctional modified electrode, two different redox couples of ruthenium oxides serve as electrocatalysts for simultaneous electrocatalytic oxidation of hydrazine and hydroxylamine. At the modified electrode surface, the peaks of differential pulse voltammetry (DPV) for hydrazine and hydroxylamine oxidation were clearly separated from each other when they co-exited in solution. Thus, it was possible to simultaneously determine hydrazine and hydroxylamine in the samples at a ruthenium oxide nanoparticles modified glassy carbon electrode (RuON-GCE). Linear calibration curves were obtained for 2.0-268.3 μM and 268.3-417.3 μM of hydrazine and for 4.0-33.8 μM and 33.8-78.3 μM of hydroxylamine at the modified electrode surface using an amperometric method. The amperometric method also exhibited the detection limits of 0.15 μM and 0.45 μM for hydrazine and hydroxylamine respectively. RuON-GCE was satisfactorily used for determination of spiked hydrazine in two water samples. Moreover, the studied bifunctional modified electrode exhibited high sensitivity, good repeatability, wide linear range and long-term stability.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号