首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A sensitive reagent-injection flow analysis method for the spectrophotometric determination of nitrate in marine, estuarine and fresh water samples is described. The method is based on the reduction of nitrate in a micro column containing zinc granules at pH 6.5. The nitrite formed is reacted with sulfanilamide and N-(1-naphthyl)ethylene diamine (Griess reagent), and the resulting azo compound is quantified spectrophotometrically at 520 nm. Water samples in the range of 3-700 μg L−1 NO3-N can be processed with a throughput of up to 40 samples per hour, a detection limit of 1.3 μg L−1 and reproducibility of 1.2% RSD (50 μg L−1 NO3-N, n = 10). The proposed method was successfully applied for the determination of nitrate in estuarine waters and the reliability was assessed by the analyses of certified reference materials and recovery experiments. The method is suitable for waters with a wide range of salinities, and was successfully used for more than 3200 underway nitrate measurements aboard SV Pelican1 in the “Two Bays” cruise in January 2010.  相似文献   

2.
A simple, sensitive and selective method for the simultaneous determination of nitrite and nitrate in water samples has been developed. The method is based on ion-exchange separation, online photochemical reaction, and luminol chemiluminescence detection. The separation of nitrite and nitrate was achieved using an anion-exchange column with a 20 mM borate buffer (pH 10.0). After the separation, these ions were converted to peroxynitrite by online UV irradiation using a low-pressure mercury lamp and then mixed with a luminol solution prepared with carbonate buffer (pH 10.0). The calibration graphs of the nitrite and nitrate were linear in the range from 2.0 × 10−9 to 2.5 × 10−6 M and 2.0 × 10−8 to 2.5 × 10−5 M, respectively. Since the sensitivity of nitrite was about 10 times higher than that of nitrate, the simultaneous determination of nitrite and nitrate in the water samples could be efficiently achieved. This method was successfully applied to various water samples – river water, pond water, rain water, commercial mineral water, and tap water – with only filtration and dilution steps.  相似文献   

3.
Wong FC  Ahmad M  Heng LY  Peng LB 《Talanta》2006,69(4):888-893
An optical biosensor consisting of a chromoionophore (ETH5294) (CM) doped sol-gel film interfaced with another sol-gel film immobilized with acetylcholinesterase (AChE) was employed to detect the insecticide dichlorvos. The main advantage of this optical biosensor is the use of a sol-gel layer with immobilized CM that possesses lipophilic property. The highly lipophilic nature of the CM and its compatibility with the sol-gel matrix has prevented leaching, which is frequently a problem in optical sensor construction based on pH indicator dyes. The immobilization of the indicator and enzyme was simple and need no chemical modification. The CM layer is pH sensitive and detects the pH changes of the acetylcholine chloride (AChCl) substrate when hydrolyzed by AChE layer deposited above. In the absence of the AChE layer, the pH response of the CM layer is linear from pH 6 to 8 (R2 = 0.98, n = 3) and it showed no leaching of the lipophilic chromoionophore. When the AChE layer is deposited on top, the optical biosensor responds to AChCl with a linear dynamic range of 40-90 mM AChCl (R2 = 0.984, n = 6). The response time of the biosensor is 12 min. Based on the optimum incubation time of 15 min, a linear calibration curve of dichlorvos against the percentage inhibition of AChE was obtained from 0.5 to 7 mg/L of dichlorvos (17-85% inhibition, R2 = 0.991, n = 9). The detection limit for dichlorvos was 0.5 mg/L. The results of the analysis of 1.7-6.0 mg/L of dichlorvos using this optical biosensor agreed well with a gas chromatography-mass spectrometry detection method.  相似文献   

4.
A novel approach was developed for nitrate analysis in a FIA configuration with amperometric detection (E = −0.48 V). Sensitive and reproducible current measurements were achieved by using a copper electrode activated with a controlled potential protocol. The response of the FIA amperometric method was linear over the range from 0.1 to 2.5 mmol L−1 nitrate with a detection limit of 4.2 μmol L−1 (S/N = 3). The repeatability of measurements was determined as 4.7% (n = 9) at the best conditions (flow rate: 3.0 mL min−1, sample volume: 150 μL and nitrate concentration: 0.5 mmol L−1) with a sampling rate of 60 samples h−1. The method was employed for the determination of nitrate in mineral water and soft drink samples and the results were in agreement with those obtained by using a recommended procedure. Studies towards a selective monitoring of nitrite were also performed in samples containing nitrate by carrying out measurements at a less negative potential (−0.20 V).  相似文献   

5.
A new approach for in situ electrodeposition of a renewable copper layer onto a copper electrode is reported. The active surface was obtained by anodic dissolution of a copper electrode at an appropriate potential and further redeposition of copper ions still remaining at the diffusion layer. Under optimal experimental conditions the peak current response increases linearly with nitrate concentration over a range of 0.1-2.5 mmol L−1. The repeatability of measurements for nitrate was evaluated as 1.8% (N = 15) and the limit of detection of the method was found to be 11 μmol L−1 (S/N = 3). Nitrate contents in two different samples (mineral water and sausages) compared well with those obtained from using the standard Griess protocol at a 95% of confidence level measured by the t-student test. The interference from chloride on the nitrate analysis and the possibility of simultaneous determination of nitrite were also examined.  相似文献   

6.
Ahmad Umar  M.M. Rahman  Y.-B. Hahn 《Talanta》2009,78(1):284-1855
This paper reports the fabrication of highly-sensitive cholesterol biosensor based on cholesterol oxidase (ChOx) immobilization on well-crystallized flower-shaped ZnO structures composed of perfectly hexagonal-shaped ZnO nanorods grown by low-temperature simple solution process. The fabricated cholesterol biosensors reported a very high and reproducible sensitivity of 61.7 μA μM−1 cm−2 with a response time less than 5 s and detection limit (based on S/N ratio) of 0.012 μM. The biosensor exhibited a linear dynamic range from 1.0-15.0 μM and correlation coefficient of R = 0.9979. A lower value of apparent Michaelis-Menten constant (Kmapp), of 2.57 mM, exhibited a high affinity between the cholesterol and ChOx immobilized on flower-shaped ZnO structures. Moreover, the effect of pH on ChOx activity on the ZnO modified electrode has also been studied in the range of 5.0-9.0 which exhibited a best enzymatic activity at the pH range of 6.8-7.6. To the best of our knowledge, this is the first report in which such a very high-sensitivity and low detection limit has been achieved for the cholesterol biosensor by using ZnO nanostructures modified electrodes.  相似文献   

7.
Melchert WR  Rocha FR 《Talanta》2005,65(2):461-465
Nitrate determination in waters is generally carried out with cadmium filings and carcinogenic reagents or by reaction with phenolic compounds in highly concentrated sulfuric acid medium. In this work, it was developed a green analytical procedure for nitrate determination in natural waters based on direct spectrophotometric measurements in ultraviolet, using a flow-injection system with an anion-exchange column for separation of nitrate from interfering species. The proposed method employs only one reagent (HClO4) in a minimum amount (equivalent to 18 μL concentrated acid per determination), and allowed nitrate determination within 0.50-25.0 mg L−1, without interference of up to 200.0 mg L−1 humic acid; 1.0 mg L−1 NO2; 200.0 mg L−1 PO43−; 75.0 mg L−1 Cl; 50.0 mg L−1 SO42− and 15.0 mg L−1 Fe3+. The detection limit (99.7% confidence level) and the coefficient of variation (n = 20) were estimated as 0.1 mg L−1 and 0.7%, respectively. The results obtained for natural water samples were in agreement with those achieved by the reference method based on nitrate reduction with copperized cadmium at the 95% confidence level.  相似文献   

8.
Chang G  Tatsu Y  Goto T  Imaishi H  Morigaki K 《Talanta》2010,83(1):61-65
Optical biosensor arrays for rapidly determining the glucose concentrations in a large number of beverage and blood samples were developed by immobilizing glucose oxidase (GOD) on oxygen sensor layer. Glucose oxidase was first encapsulated in silica based gels through sol-gel approach and then immobilized on 96-well microarrays integrated with oxygen sensing film at the bottom. The oxygen sensing film was made of an organically modified silica film (ORMOSIL) doped with tris(4,7-diphenyl-1,10-phenanthroline) ruthenium dichloride (Ru(dpp)3Cl2). The oxidation reaction of glucose by glucose oxidase could be monitored through fluorescence intensity enhancement due to the oxygen consumption in the reaction. The luminescence changing rate evaluated by the dynamic transient method (DTM) was correlated with the glucose concentration with the wide linear range from 0.1 to 5.0 mM (Y = 13.28X − 0.128, R = 0.9968) and low detection limit (0.06 mM). The effects of pH and coexisting ions were systemically studied. The results showed that the optical biosensor arrays worked under a wide range of pH value, and normal interfering species such as Na+, K+, Cl, PO43−, and ascorbic acid did not cause apparent interference on the measurement. The activity of glucose oxidase was mostly retained even after 2-month storage, indicating their long-term stability.  相似文献   

9.
Tyrosinase from a plant source Amorphophallus companulatus was immobilized on eggshell membrane using glutaraldehyde. Among the three different approaches used for immobilization, activation of eggshell membrane by glutaraldehyde followed by enzyme adsorption on activated support could stabilize the enzyme tyrosinase and was found to be effective. Km and Vmax values for dopamine hydrochloride calculated from Lineweaver-Burk plot were 0.67 mM and 0.08 mM min−1, respectively. Studies on effect of pH showed retention of more than 90% activity over a pH range 5.0-6.5. Membrane bound enzyme exhibited consistent activity in the temperature range 20-45 °C. Shelf life of immobilized tyrosinase system was found to be more than 6 months when stored in phosphate buffer at 4 °C. An electrochemical biosensor for dopamine was developed by mounting the tyrosinase immobilized eggshell membrane on the surface of glassy carbon electrode. Dopamine concentrations were determined by the direct reduction of biocatalytically liberated quinone species at −0.19 V versus Ag/AgCl (3 M KCl). Linearity was observed within the range of 50-250 μM with a detection limit of 25 μM.  相似文献   

10.
In this work, we reported an efficient platinum nanoparticles functionalized nitrogen doped graphene (PtNPs@NG) nanocomposite for devising novel electrochemical glucose biosensor for the first time. The fabricated PtNPs@NG and biosensor were characterized using transmission electron microscopy, high-resolution transmission electron microscopy, X-ray photoelectron spectroscopy, static water contact angle, UV–vis spectroscopy, electrochemical impedance spectra and cyclic voltammetry, respectively. PtNPs@NG showed large surface area and excellent biocompatibility, and enhanced the direct electron transfer between enzyme molecules and electrode surface. The glucose oxidase (GOx) immobilized on PtNPs@NG nanocomposite retained its bioactivity, and exhibited a surface controlled, quasi-reversible and fast electron transfer process. The constructed glucose biosensor showed wide linear range from 0.005 to 1.1 mM with high sensitivity of 20.31 mA M−1 cm−2. The detection limit was calculated to be 0.002 mM at signal-to-noise of 3, which showed 20-fold decrease in comparison with single NG-based electrochemical biosensor for glucose. The proposed glucose biosensor also demonstrated excellent selectivity, good reproducibility, acceptable stability, and could be successfully applied in the detection of glucose in serum samples at the applied potential of −0.33 V. This research provided a promising biosensing platform for the development of excellent electrochemical biosensors.  相似文献   

11.
New silver nanoparticles coated with EDTA (EDTA-AgNPs) have been synthesized by citrate reduction method and characterized by UV-vis spectroscopy, molecular fluorescence and scanning electron microscopy (SEM). The derivatized nanoparticles show fluorescent emission and second order scattering (SOS) signals which in presence of nitrate are both attenuated. The SOS decreasing is greater than its fluorescent quenching; considering this fact, a new ultra sensitive methodology using the derivatized silver nanoparticles as sensor for nitrate determination has been developed. Under optimal established conditions, a linear response has been obtained within the range of 6.4 × 10−4 to 3.0 μg mL−1 nitrate concentrations, with a detection limit of 1.8 × 10−4 μg mL−1. This novel technique provides a sensitive and selective methodology for nitrate determination and has been satisfactorily applied to its quantification in parenteral solutions.  相似文献   

12.
A.K. Upadhyay 《Talanta》2009,79(1):38-9495
A novel amperometric biosensor for the analytical determination of hydrogen peroxide was developed. The fabrication of the biosensor was based on the coimmobilization of horseradish peroxidase (HRP), methylene green (MG) and multiwalled carbon nanotubes within ormosils; 3-aminopropyltrimethoxysilane (APTMOS), 2-(3,4-epoxycyclohexyl)ethyltrimethoxysilane (ETMOS) and phenyltrimethoxysilane (PHTMOS). APTMOS determined the hydrophilicity/hydrophobicity of the ormosils and PHTMOS and ETMOS increased the physical and mechanical strength of the ormosil matrix. The ormosil modified electrodes were characterized with SEM, UV-vis spectroscopy and electrochemical methods. Cyclic voltammetry and amperometric measurements demonstrated the MG coimmobilized with HRP in this way, displayed good stability and could efficiently shuttle electrons between immobilized enzyme and electrode, and MWCNTs facilitated the electrocatalytic reduction of H2O2 at reduced over potential. The Micheaelis constant of the immobilized HRP was 1.8 mM, indicating a high affinity of the HRP to H2O2 without loss of enzymatic activity in ormosil matrix. The prepared biosensor had a fast response of H2O2, less than 10 s, and excellent linear range of concentration from 5 × 10−7 to 2 × 10−5 M with the detection limit of 0.5 μM (S/N = 3) under the optimum conditions. At the same time, the influence of solution pH, effect of enzyme amount, steady-state applied potential and temperature on the biosensor were investigated. The enzyme electrode retained about 90% of its initial activity after 30 days of storage in a dry state at 4 °C. The preparation of the developed biosensor was convenient and showed high sensitivity with good stability.  相似文献   

13.
A microbial biosensor for 2-phenylethanol (2-PE) based on the bacteria Gluconobacter oxydans was developed and applied in monitoring of a biotechnological process. The cells of G. oxydans were immobilized within a disposable polyelectrolyte complex gel membrane consisting of sodium alginate, cellulose sulphate and poly(methylene-co-guanidine) attached onto a miniaturized Clark oxygen electrode, forming whole cell amperometric biosensor. Measured changes in oxygen concentration were proportional to changes in 2-PE concentration. The biosensor sensitivity was 864 nA mM−1 (RSD = 6%), a detection limit of 1 μM, and the biosensor response towards 2-PE was linear in the range 0.02–0.70 mM. The biosensor preserved 93% of its initial sensitivity after 7 h of continuous operation and exhibited excellent storage stability with loss of only 6% of initial sensitivity within two months, when stored at 4 °C. The developed system was designed and successfully used for an off-line monitoring of whole course of 2-PE biooxidation process producing phenylacetic acid (PA) as industrially valuable aromatic compound. The biosensor measurement did not require the use of hazardous organic solvent. The biosensor response to 2-PE was not affected by interferences from PA and phenylacetaldehyde at concentrations present in real samples during the biotransformation and the results were in a very good agreement with those obtained via gas chromatography.  相似文献   

14.
Spectrophotometric flow injection methods were developed for the individual determination of nitrite or nitrate, and for the simultaneous determination of nitrite and nitrate, in soil samples. Nitrite was determined directly using a modified version of the Griess-Ilosvay diazo-coupling reaction, measuring at 543 nm the absorbance of the azo-dye complex formed. Simultaneous nitrite and nitrate determinations were based on on-line nitrate reduction in a micro column containing copperised cadmium. A single chromogenic reagent containing all the necessary reactants was used in both methods. For determinations, the chemical and instrumental variables were optimised by univariate analysis and simplex chemometric method. The optimised conditions gave a linear calibration range between 0.05 and 1.6 µg m L− 1 for N-NO2 and between 0.05 and 7.0 µg m L− 1 for N-NO3. The detection limits for nitrite and nitrate were 22 µg L− 1 and 44 µg L− 1 respectively. The proposed methods allowed up to 35-40 samples per hour to be analysed with good precision. The simultaneous method was successfully used for the determination of nitrite and nitrate in soil samples (the results obtained were validated against those obtained by reference methods). The proposed methods are simpler and faster than conventional methods and could be routinely used in environmental monitoring laboratories.  相似文献   

15.
A rapid, simple miniaturised photometrical method was developed for the determination of nitrate and/or nitrite in freshwater samples. All procedures, including sample buffering, reduction by copperised cadmium granules, colour development and absorbance determination, were completed in a 96-well microplate. The factors governing the nitrate reduction and its recovery were investigated in detail, and the optimised analysing conditions were established. Nitrate was quantitatively reduced by copperised cadmium granules with a high reduction efficiency (96.59 ± 0.96%). The proposed method gave a linear calibration ranging from 0.01 to 1.50 mg L−1 for NO2-N and 0.02 to 1.50 mg L−1 for NO3-N. The detection limits for nitrite and nitrate were 2 and 4 μg L−1, respectively. The proposed method allowed at least 48 samples to be simultaneously analysed in duplicate, with good precision, within 90 min for nitrate and 30 min for nitrite, and was successfully applied to actual freshwater sample analysis with a recovery of 98.02 ± 1.04% for nitrite and 99.72 ± 1.39% for nitrate. This method produced accurate results comparable to standard methods, provided a much higher sample throughput than conventional methods and could be routinely used in actual freshwater sample monitoring.  相似文献   

16.
A colloidal suspension of nanostructured poly(N-butyl benzimidazole)-graphene sheets (PBBIns-Gs) was used to modify a gold electrode to form a three-dimensional PBBIns-Gs/Au electrode that was sensitive to hydrogen peroxide (H2O2) in the presence of acetic acid (AcOH). The positively charged nanostructured poly(N-butyl benzimidazole) (PBBIns) separated the graphene sheets (Gs) and kept them suspended in an aqueous solution. Additionally, graphene sheets (Gs) formed “diaphragms” that intercalated Gs, which separated PBBIns to prevent tight packing and enhanced the surface area. The PBBIns-Gs/Au electrode exhibited superior sensitivity toward H2O2 relative to the PBBIns-modified Au (PBBIns/Au) electrode. Furthermore, a high yield of glucose oxidase (GOD) on the PBBIns-Gs of 52.3 mg GOD per 1 mg PBBIns-Gs was obtained from the electrostatic attraction between the positively charged PBBIns-Gs and negatively charged GOD. The non-destructive immobilization of GOD on the surface of the PBBIns-Gs (GOD-PBBIns-Gs) retained 91.5% and 39.2% of bioactivity, respectively, relative to free GOD for the colloidal suspension of the GOD-PBBIns-Gs and its modified Au (GOD-PBBIns-Gs/Au) electrode. Based on advantages including a negative working potential, high sensitivity toward H2O2, and non-destructive immobilization, the proposed glucose biosensor based on an GOD-PBBIns-Gs/Au electrode exhibited a fast response time (5.6 s), broad detection range (10 μM to 10 mM), high sensitivity (143.5 μA mM−1 cm−2) and selectivity, and excellent stability. Finally, a choline biosensor was developed by dipping a PBBIns-Gs/Au electrode into a choline oxidase (ChOx) solution for enzyme loading. The choline biosensor had a linear range of 0.1 μM to 0.83 mM, sensitivity of 494.9 μA mM−1 cm−2, and detection limit of 0.02 μM. The results of glucose and choline measurement indicate that the PBBIns-Gs/Au electrode provides a useful platform for the development of oxidase-based biosensors.  相似文献   

17.
A new electrogenerated chemiluminescence biosensor was fabricated by immobilizing ECL reagent Ru(bpy)32+ and alcohol dehydrogenase in sol-gel/chitosan/poly(sodium 4-styrene sulfonate) (PSS) organically modified composite material. The component PSS was used to immobilize ECL reagent Ru(bpy)32+ by ion-exchange, while the addition of chitosan was to prevent the cracking of conventional sol-gel-derived glasses and provide biocompatible microenvironment for alcohol dehydrogenase. Such biosensor combined enzymatic selectivity with the sensitivity of ECL detection for quantification of enzyme substrate and it was much simpler than previous double-layer design. The detection limit was 9.3 × 10−6 M for alcohol (S/N = 3) with a linear range from 2.79 × 10−5 to 5.78 × 10−2 M. With ECL detection, the biosensor exhibited wide linear range, high sensitivity and good stability.  相似文献   

18.
A new biosensor for detection of phenols, based on tyrosinase immobilization with alumina sol-gel on Sonogel-Carbon transducer, has been developed. The electrode was prepared using high energy ultrasounds directly applied to the precursors. The alumina sol-gel provided a microenvironment for retaining the native structure and activity of the entrapped enzyme and a very low mass transport barrier to the enzyme substrates. Phenols are oxidized by tyrosinase biosensor to form a detectable product, which was determined at −300 mV vs. Ag/AgCl reference electrode. For phenol, the sensor exhibited a fast response which resulted from the porous structure and high enzyme loading of the sol-gel matrix. The linear range was from 5 × 10−7 M to 3 × 10−5 M, with a detection limit of 3 × 10−7 M. The stability of the biosensor was also evaluated.  相似文献   

19.
The construction and evaluation of a Low Temperature Co-fired Ceramics (LTCC)-based continuous flow potentiometric microanalyzer prototype to simultaneously monitor the presence of two ions (potassium and nitrate) in samples from the water recycling process for future manned space missions is presented. The microsystem integrates microfluidics and the detection system in a single substrate and it is smaller than a credit card. The detection system is based on two ion-selective electrodes (ISEs), which are built using all-solid state nitrate and potassium polymeric membranes, and a screen-printed Ag/AgCl reference electrode. The obtained analytical features after the optimization of the microfluidic design and hydrodynamics are a linear range from 10 to 1000 mg L−1 and from 1.9 to 155 mg L−1 and a detection limit of 9.56 mg L−1 and 0.81 mg L−1 for nitrate and potassium ions respectively.  相似文献   

20.
M. Piano  R. Pittson  J.P. Hart 《Talanta》2010,82(1):34-2193
A biosensor for the measurement of lactate in serum has been developed, which is based on a screen-printed carbon electrode, modified with Meldola's Blue-Reinecke Salt (MBRS-SPCE), coated with the enzyme lactate dehydrogenase NAD+ dependent (from Porcine heart), and NAD+. A cellulose acetate layer was deposited on the top of the device to act as a permselective membrane. The biosensor was incorporated into a commercially available, thin-layer, amperometric flow cell operated at a potential of only +0.05 V vs. Ag/AgCl. The mobile phase consisted of 0.2 M phosphate buffer pH 10 containing 0.1 M potassium chloride solution; a flow rate of 0.8 ml min−1 was used throughout the investigation. The biosensor response was linear over the range 0.55-10 mM lactate; the former represents the detection limit. The precision of the system was determined by carrying out 10 repeat injections of 10 mM l(+)lactic acid standard; the calculated coefficient of variation was 4.28%. It was demonstrated that this biosensor system could be applied to the direct measurement of lactate in serum without pre-treatment; therefore, this would allow high throughput-analysis, at low cost, for this clinically important analyte.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号