首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A simple and rapid method for the highly sensitive determination of polycyclic aromatic hydrocarbons (PAHs) in water was developed. Benzo[a]pyrene, benzo[k]fluoranthene, perylene, and pyrene in water were concentrated into sodium dodecyl sulfate (SDS)-alumina admicelles. The collection was performed by adding SDS and alumina particles into the sample solution at pH 2. After gentle mixing, the resulting suspension was passed through a membrane filter to collect the SDS admicelles containing highly concentrated PAHs. The filter was placed on a slide glass and then covered admicellar layer with a fused silica glass plate before setting in a fluorescence spectrometer. Benzo[a]pyrene, benzo[k]fluoranthene, perylene, and pyrene were selectively determined by the synchronous fluorescence scan (SFS) analysis with keeping wavelength intervals between excitation and emission to 98, 35, 29, and 45 nm, respectively. Because of the minimum spectral overlapping, 1-40 ng l−1 of benzo[a]pyrene, benzo[k]fluoranthene, and perylene as well as 10-150 ng l−1 of pyrene were selectively determined with eliminating the interferences of other 12 PAHs. The detection limits were 0.3 ng l−1 for benzo[a]pyrene, benzo[k]fluoranthene, and perylene, and 1 ng l−1 for pyrene. They were 2-3 orders of magnitude lower than the detection limits in normal aqueous micellar solutions. The application to water analysis was studied.  相似文献   

2.
This study reported for the first time the use of cholesterol-functionalized magnetic nanoparticles (Fe3O4@SiO2@Chol) for the determination of polycyclic aromatic hydrocarbons (PAHs) in traditional Chinese medicine samples (TCMs) by high performance liquid chromatography (HPLC) coupled with fluorescence detection. The method was efficient, environmentally friendly, and fast. The solvent consumption of the proposed column is only half of the conventional column but with higher efficiency. Influencing factors, including sorbent amount, desorption solvent, sample volume and extraction time, were investigated in detail. Under the optimum conditions, good linearity (R2 > 0.991) was obtained over the range of 5–400 ng g−1, with limits of detection (LOD) 0.75, 0.50, 1.0, 0.56, 0.60, 0.84 and 0.80 ng g−1 for anthracene, fluoranthene, pyrene, chrysene, benzo[a]anthracene, benzo(b)fluoranthene and benzo(k)fluoranthene, respectively.  相似文献   

3.
The suitability of coacervates for the preservation of organic pollutants after their extraction from water samples was investigated for the first time. Acid-induced sodium dodecanesulfonic acid (SDSA) micelle-based coacervates were selected for this purpose. Their capacity to preserve benzalkonium homologue (C12, C14 and C16) surfactants (BASs) and different polycyclic aromatic hydrocarbons (PAHs) [benzo(a)pyrene (BaP), benzo(b)fluoranthene (BbF), benzo(k)fluoranthene (BkF), benzo(ghi)perylene (BghiP), benzo(a)anthracene (BaA) and indene(1,2,3-c-d)pyrene (IP)] was investigated. BASs and PAHs were efficiently extracted by the coacervate by formation of mixed aggregates and hydrophobic interactions, respectively. Their stability into the coacervate was investigated under three temperature conditions (room temperature, 4 °C and −20 °C) and two hydrochloric acid concentrations (3.75 M and 4.2 M), which was used to induce coacervation. No losses were observed during at least 3 months at the different experimental conditions tested. The increase of the temperature up to 35 °C for a month did not affect the stability of the target compounds. No influence of the water matrix (distilled, river or wastewater) on the stabilization of BASs and PAHs was observed. The high-stabilizing capacity of the coacervate for the target compounds and its low volume make easy the transport and storage of analytes.  相似文献   

4.
A microwave-assisted sample preparation (MASP) procedure was developed for the analysis of polycyclic aromatic hydrocarbons (PAHs) in sewage sludge and soil samples. The procedure involved the simultaneous microwave-assisted extraction of PAHs with n-hexane and the hydrolysis of samples with methanolic potassium hydroxide. Because of the complex nature of the samples, the extracts were submitted to further cleaning with silica and Florisil solid-phase extraction cartridges connected in series. Naphthalene, acenaphthene, fluorene, phenanthrene, anthracene, fluoranthene, pyrene, benz[a]anthracene, chrysene, benzo[e]pyrene, benzo[b]fluoranthene, benzo[k]fluoranthene, benzo[a]pyrene, dibenz[a,h]anthracene, benzo[g,h,i]perylene, and indeno[1,2,3-cd]pyrene, were considered in the study. Quantification limits obtained for all of these compounds (between 0.4 and 14.8 μg kg−1 dry mass) were well below of the limits recommended in the USA and EU. Overall recovery values ranged from 60 to 100%, with most losses being due to evaporation in the solvent exchange stages of the procedure, although excellent extraction recoveries were obtained. Validation of the accuracy was carried out with BCR-088 (sewage sludge) and BCR-524 (contaminated industrial soil) reference materials.  相似文献   

5.
Very simple and highly sensitive methods are presented for the determination of benzo[a]pyrene, one of the most carcinogenic polycyclic aromatic hydrocarbons (PAHs). The approaches are based on solid-phase extraction of the analyte on a nylon membrane via a syringe procedure, and its fluorescent or phosphorescent determination on the solid surface. While the native fluorescence of benzo[a]pyrene retained on a nylon surface is measured directly, room-temperature phosphorescence is induced by spotting a few microlitres of thallium(I) nitrate solution on the surface (heavy-atom effect). An enhancement of the phosphorescence signal was corroborated when the measurements were carried under a nitrogen atmosphere. The analytical figures of merit obtained under the best experimental conditions demonstrate the capability of detecting benzo[a]pyrene at a sub-parts-per-trillion (sub-ng L−1) level. The potential interference from other common PAHs and also from different metal ions was studied. The feasibility of determining benzo[a]pyrene in real samples was successfully evaluated through the analysis of spiked tap, underground and mineral water samples of different origins. Recoveries obtained from spiked river waters were successfully compared with those provided by a reference method, through rigorous statistical analysis.  相似文献   

6.
The total and bioaccessible concentration of 16 polycyclic aromatic hydrocarbons (PAHs) in soil from a former industrial site was investigated. Typical total concentrations across the sampling sites ranged from 1.5 mg kg−1 for acenaphthylene up to 243 mg kg−1 for fluoranthene. The oral bioaccessibility of PAHs in soil was assessed using an in vitro gastrointestinal extraction (Fed Organic Estimation human Simulation Test, FOREhST method). The oral bioaccessibility data indicated that fluorene, phenanthrene, chrysene, indeno(1,2,3-cd)pyrene and dibenzo(a,h)anthracene had the highest % bioaccessible fraction (based on their upper 75th percentile values being >60%) while the other PAHs had lower % bioaccessible fractions (means ranging between 35 and 59%). Significantly lower bioaccessibilities were determined for naphthalene. With respect to method validation and inter-laboratory comparison, the total and bioaccessible concentrations of benzo(a)anthracene, benzo(b)anthracene, benzo(k)fluoranthene, benzo(a)pyrene, indeno(1,2,3-cd)pyrene and dibenzo(a,h)anthracene was compared to published data derived using the same samples. The total PAH concentrations at the site were compared with generic assessment criteria (GAC) using the residential land use scenario (with plant uptake at 6% soil organic matter). Concentrations of 7 of the PAHs investigated within the soils could lead to an unacceptable risk to human health at this site.  相似文献   

7.
We describe here a method for detecting and quantifying the highly carcinogenic polycyclic aromatic hydrocarbon (PAH) benzo[a]pyrene (BaP) in water, based on a flow-trough optical sensor. The technique is fast (response time of 40 s) and simple and at the same time meets the standards of sensitivity and selectivity required by the European Guidelines on Water for Human Consumption. The optosensor is based on the on-line immobilization of BaP on a non-ionic resin (Amberlite XAD-4) solid support in a continuous-flow system. BaP was analyzed in a 15 mM H2PO4/HPO42− buffer solution with 25% (v/v) 1,4-dioxane at pH 7. Fluorescence intensity was measured at λex/em=392/406 nm. The experimental conditions (reagent phase, pH, type and concentration of buffer solution and organic solvent) and flow-injection values (flow rate and injection volume) were carefully controlled. Under these conditions the optosensor was sensitive to a linear concentration range of between 3.0 and 250.0 ng l−1 with a detection limit of 3.0 ng l−1 and a standard deviation of 1.5% at 150 ng l−1. The optosensor was applied to the quantification of BaP in drinking and waste water samples (95-105% recovery) in presence of the other 15 EPA PAHs at 1000 ng l−1 concentration level. The influence of other fluorescent polycyclic aromatic hydrocarbons and potential interference from ions usually present in water was also evaluated.  相似文献   

8.
The efficiency of extraction of polycyclic aromatic hydrocarbons (PAHs) with molecular masses of 252, 276, 278, 300, and 302 Da from standard reference material diesel particulate matter (SRM 2975) has been investigated using accelerated solvent extraction (ASE) with dichloromethane, toluene, methanol, and mixtures of toluene and methanol. Extraction of SRM 2975 using toluene/methanol (9:1, v/v) at maximum instrumental settings (200 °C, 20.7 MPa, and five extraction cycles) with 30-min extraction times resulted in the following elevations of the measured concentration when compared with the certified and reference concentrations reported by the National Institute of Standards and Technology (NIST): benzo[b]fluoranthene, 46%; benzo[k]fluoranthene, 137%; benzo[e]pyrene, 103%; benzo[a]pyrene, 1,570%; perylene, 37%; indeno[1,2,3-cd]pyrene, 41%; benzo[ghi]perylene, 163%; and coronene, 361%. The concentrations of the following PAHs were comparable to the reference values assigned by NIST: indeno[1,2,3-cd]fluoranthene, dibenz[a,h]anthracene, and picene. The measured concentration of dibenzo[a,e]-pyrene was lower than the information value reported by the NIST. The measured concentrations of other highly carcinogenic PAHs (dibenzo[a,l]pyrene, dibenzo[a,i]pyrene, and dibenzo[a,h]pyrene) in SRM 2975 are also reported. Comparison of measurements using the optimized ASE method and using similar conditions to those applied by the NIST for the assignment of PAH concentrations in SRM 2975 indicated that the higher values obtained in the present study were associated with more complete extraction of PAHs from the diesel particulate material. Re-extraction of the particulate samples demonstrated that the deuterated internal standards were more readily recovered than the native PAHs, which may explain the lower values reported by the NIST. The analytical results obtained in the study demonstrated that the efficient extraction of PAHs from SRM 2975 is a critical requirement for the accurate determination of PAHs with high molecular masses in this standard reference material and that the optimization of extraction conditions is essential to avoid underestimation of the PAH concentrations. The requirement is especially relevant to the human carcinogen benzo[a]pyrene, which is commonly used as an indicator of the carcinogenic risk presented by PAH mixtures.  相似文献   

9.
Seven heavy polycyclic aromatic hydrocarbons (PAHs) of concern on the US Environmental Protection Agency priority pollutant list (benzo[a]anthracene, benzo[b]fluoranthene, benzo[k]fluoranthene, benzo[a]pyrene, dibenz[a,h]anthracene, benzo[g,h,i]perylene, and indeno[1,2,3-c,d]-pyrene) were simultaneously analyzed in extra virgin olive oil. The analysis is based on the measurement of excitation–emission matrices on nylon membrane and processing of data using unfolded partial least-squares regression with residual bilinearization (U-PLS/RBL). The conditions needed to retain the PAHs present in the oil matrix on the nylon membrane were evaluated. The limit of detection for the proposed method ranged from 0.29 to 1.0 μg kg?1, with recoveries between 64 and 78 %. The predicted U-PLS/RBL concentrations compared favorably with those measured using high-performance liquid chromatography with fluorescence detection. The proposed method was applied to ten samples of edible oil, two of which presented PAHs ranging from 0.35 to 0.63 μg kg?1. The principal advantages of the proposed analytical method are that it provides a significant reduction in time and solvent consumption with a similar limit of detection as compared with chromatography.
Figure
The excitation-emission fluorescence spectroscopy on nylon membranes, associated with U-PLS/RBL, is a useful tool for resolving a mixture of PAHs in the presence of a complex matrix such as that of edible oils.  相似文献   

10.
Nuno Ratola  Damià Barceló 《Talanta》2009,77(3):1120-1128
Two different extraction strategies (microwave-assisted extraction (MAE) and ultrasonic extraction (USE)) were tested in the extraction of the 16 US Environmental Protection Agency (EPA) polycyclic aromatic hydrocarbons (PAHs) from pine trees. Extraction of needles and bark from two pine species common in the Iberian Peninsula (Pinus pinaster Ait. and Pinus pinea L.) was optimized using two amounts of sample (1 g and 5 g) and two PAHs spiking levels (20 ng/g and 100 ng/g). In all cases, the clean-up procedure following extraction consisted in solid-phase extraction (SPE) with alumina cartridges. Quantification was done by gas chromatography (GC) with mass spectrometry (MS), using five deuterated PAH surrogate standards as internal standards. Limits of detection were globally below 0.2 ng/g. The method was robust for the matrices studied regardless of the extraction procedures. Recovery values between 70 and 130% were reached in most cases, except for high molecular weight PAHs (indeno[1,2,3-cd]pyrene, dibenzo[a,h]anthracene and benzo[ghi]perylene). A field study with naturally contaminated samples from eight sites (four in Portugal and four in Catalonia, Spain) showed that needles are more suitable biomonitors for PAHs, yielding concentrations from 2 to 17 times higher than those found in bark. The levels varied according to the sampling site, with the sum of the individual PAH concentrations between 213 and 1773 ng/g (dry weight). Phenanthrene was the most abundant PAH, followed by fluoranthene, naphthalene and pyrene.  相似文献   

11.
With the emergence of highly sensitive analytical techniques, the microanalysis of natural-matrix materials employing smaller sample sizes is increasingly more common, which subsequently warrants a homogeneity assessment for the individual components at the appropriate sampling level. Pressurized liquid extraction (PLE) in combination with gas chromatography/mass spectrometry (GC/MS) has been used to determine the sampling constants and evaluate the relative homogeneity of trace levels of polycyclic aromatic hydrocarbons (PAHs) for two previously certified particulate standard reference materials, SRM 1649a Urban Dust and SRM 1650b Diesel Particulate Matter, in the milligram sampling range. Fluoranthene, pyrene, benz[a]anthracene and benzo[e]pyrene within SRM 1650b Diesel Particulate Matter were deemed to be homogeneous, based on relatively small sampling constants (K S<100 mg), whereas the larger sampling constants (K S>100 mg) obtained for all PAHs in SRM 1649a Urban Dust suggest more material heterogeneity. The material heterogeneity of ten individual PAHs (phenanthrene, anthracene, fluoranthene, pyrene, benz[a]anthracene, benzo[k]fluoranthene, benzo[e]pyrene, benzo[a]pyrene, indeno[1,2,3-cd]pyrene and benzo[ghi]perylene) was also described via nonlinear relationships (i.e., power law) between subsampling error S s (%) and sample mass, which are used to predict analyte-specific minimum sample masses that result in a specific level of analytical uncertainty. Electronic supplementary material Supplementary material is available for this article at and is accessible for authorized users.  相似文献   

12.
As a sequel to an earlier paper, we have studied the behaviour of 1-fluoropyrene and pyrene in lamp-excited Shpol’skii spectrofluorimetry at 11 K in two different matrices, n-octane and n-hexane, using two different solidification processes. Particular attention is paid to the suitability of 1-fluoropyrene as an internal standard (IS) to correct for different sources of variability. As a demonstration of the applicability of this approach, four polycyclic aromatic hydrocarbons (PAHs; pyrene, chrysene, benzo[a]pyrene and benzo[k]fluoranthene) were determined in a river sediment extract. The results agreed well with those obtained by HPLC with fluorescence detection.  相似文献   

13.
This work presents a green and very simple approach which enables the accurate and simultaneous determination of benzo[a]pyrene, dibenz[a,h]anthracene, benz[a]anthracene, and chrysene, concerned and potentially carcinogenic heavy-polycyclic aromatic hydrocarbons (PAHs) in interfering samples. The compounds are extracted from water samples onto a device composed of a small rotating Teflon disk, with a nylon membrane attached to one of its surfaces. After extraction, the nylon membrane containing the concentrated analytes is separated from the Teflon disk, and fluorescence excitation–emission matrices are directly measured on the nylon surface, and processed by applying parallel factor analysis (PARAFAC), without the necessity of a desorption step. Under optimum conditions and for a sample volume of 25 mL, the PAHs extraction was carried out in 20 min. Detection limits based on the IUPAC recommended criterion and relative errors of prediction were in the ranges 20–100 ng L−1 and 5–7%, respectively. Thanks to the combination of the ability of nylon to strongly retain PAHs, the easy rotating disk extraction approach, and the selectivity of second-order calibration, which greatly simplifies sample treatment avoiding the use of toxic solvents, the developed method follows most green analytical chemistry principles.  相似文献   

14.
The hydrophobic octadecyl (C18) functionalized Fe3O4 magnetic nanoparticles (Fe3O4@C18) were caged into hydrophilic barium alginate (Ba2+-ALG) polymers to obtain a novel type of solid-phase extraction (SPE) sorbents, and the sorbents were applied to the pre-concentration of polycyclic aromatic hydrocarbons (PAHs) and phthalate esters (PAEs) pollutants from environmental water samples. The hydrophilicity of the Ba2+-ALG cage enhances the dispersibility of sorbents in water samples, and the superparamagnetism of the Fe3O4 core facilitates magnetic separation. With the magnetic SPE technique based on the Fe3O4@C18@Ba2+-ALG sorbents, it requires only 30 min to extract trace levels of analytes from 500 mL water samples. After the eluate is condensed to 0.5 mL, concentration factors for both phenanthrene and di-n-propyl-phthalate are over 500, while for other analytes are about 1000. The recoveries of target compounds are independent of salinity and solution pH under testing conditions. Under optimized conditions, the detection limits for phenanthrene, pyrene, benzo[a]anthracene, and benzo[a]pyrene are 5, 5, 3, and 2 ng L−1, and for di-n-propyl-phthalate, di-n-butyl-phthalate, di-cyclohexyl-phthalate, and di-n-octyl-phthalate are 36, 59, 19, and 36 ng L−1, respectively. The spiked recoveries of several real water samples for PAHs and PAEs are in the range of 72-108% with relative standard deviations varying from 1% to 9%, showing good accuracy of the method. The advantages of the new SPE method include high extraction efficiency, short analysis time and convenient extraction procedure. To the best of our knowledge, it is unprecedented that hydrophilic Ba2+-ALG polymer caged Fe3O4@C18 magnetic nanomaterial is used to extract organic pollutants from large volumes of water samples.  相似文献   

15.
An extraction/clean-up procedure by SFE was developed for isolating PAHs from liver samples for subsequent HPLC-FL determination of ten PAHs in the enriched extract. Recoveries (90–115%) and RSD % (≤ 7.7) were satisfactory. When applied to 11 samples of bird of prey (Tyto alba) protected species and classified of special interest, from the Galicia (Northwest to Spain), benzo[ghi]perylene and indeno[1,2,3-cd]pyrene were undetectable; chrysene and benzo[a]pyrene are only detected in one sample; benzo[a]anthracene and benzo[k]fluoranthene are only quantified in one sample and benzo[b]fluoranthene in two samples. The other PAHs, anthracene, fluoranthene and pyrene are present in almost all the samples.  相似文献   

16.
An extraction/clean-up procedure by SFE was developed for isolating PAHs from liver samples for subsequent HPLC-FL determination of ten PAHs in the enriched extract. Recoveries (90-115%) and RSD % (< or =7.7) were satisfactory. When applied to 11 samples of bird of prey (Tyto alba) protected species and classified of special interest, from the Galicia (Northwest to Spain), benzo[ghi]perylene and indeno[1,2,3-cd]pyrene were undetectable; chrysene and benzo[a]pyrene are only detected in one sample; benzo[a]anthracene and benzo[k]fluoranthene are only quantified in one sample and benzo[b]fluoranthene in two samples. The other PAHs, anthracene, fluoranthene and pyrene are present in almost all the samples.  相似文献   

17.
This paper presents an optosensor for screening of four polycyclic aromatic hydrocarbons: anthracene (ANT), benzo[a]pyrene (BaP), fluoranthene (FLT), and benzo[b]fluoranthene (Bbf) using a photomultiplier device with an artificial neural network as transducer. The optosensor is based on the on-line immobilization on a non-ionic resin (Amberlite XAD-4) solid support in a continuous flow. The determination was performed in 15 mM H2PO4/HPO42− buffer solution at pH 7 and 25% of 1,4-dioxane. Feed forward neural networks (multiplayer perceptron) have been trained to quantify the considered Polycyclic aromatic hydrocarbons (PAHs) in mixtures under optimal conditions. The optosensor proposed was also applied satisfactorily to the determination of the considered PAHs in water samples in presence of the other 12 EPA–PAHs.  相似文献   

18.
19.
Using cotton as a solid-phase extraction sorbent of the precolumn, an on-line coupled precolumn preconcentration-liquid chromatography system with fluorescence detection was developed for the determination of PAHs in aqueous samples. Four PAHs including fluorene, phenanthrene, fluoranthene and benzo[k]fluoranthene were preconcentrated by a precolumn packed with 30 mg of absorbent cotton and then separated by C18 analytical column. When 100 ml of sample was enriched, the proposed procedure provided detection limits in the range of 0.5-57 ng l−1. Several water samples spiked with PAHs were analyzed with recoveries in the range of 92-119% at spiking level of 100 ng l−1 for fluorene, phenanthrene and fluoranthene, and 10 ng l−1 for benzo[k]fluoranthene, respectively.  相似文献   

20.
A pressurized liquid extraction (PLE) method has been optimized for the determination of polycyclic aromatic hydrocarbons (PAHs) in soil samples and it was compared with ultrasonic extraction. The extraction step was followed by gas chromatography-triple quadrupole mass spectrometry (GC-QqQ-MS/MS) analysis. Parameters such as type of solvent, extraction time, extraction temperature and number of extractions were optimized. There were no significant differences among the two extraction methods although better extraction efficiencies were obtained when PLE was used, minimizing extraction time and solvent consumption. PLE procedure was validated, obtaining limits of detection (LODs) ranging from 0.02 to 0.75 μg kg−1 and limits of quantification (LOQs) ranging from 0.07 to 2.50 μg kg−1 for the selected PAHs. Recoveries were in the range of 59-110%, except for naphthalene, which was the most volatile PAH. Finally, the method was applied to real soil samples from Southeast of Spain. PAHs concentrations were low, and phenanthrene, pyrene, fluorene, benzo[a]pyrene and chrysene were the most frequently detected analytes in the samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号