 共查询到20条相似文献,搜索用时 109 毫秒
1.
We describe a multifunctional flow analysis instrument that is portable ( cm, 2.3 kg) for facile field deployment. Using a 50 cm long Teflon® AF tubing as final reaction and optical measurement conduit, we combine a liquid-core waveguide (LCW) based fluorescence detector that is transversely illuminated by an addressable light emitting diode array, a chemiluminescence (CL) detector and an absorbance detector with a solid-state broadband (400-700 nm) source. Several illustrative experiments have been carried out to test the performance of the instrument in different detection modes. A S/N=3 limit of detection (LOD) of 0.25 μg l−1 for chromium(VI) was established using the diphenylcarbazide chemistry, and an LOD of 5 μg l−1 was similarly established for Al(III), using Pyrocatechol Violet (PCV) as the chelating chromogenic dye, in both cases using long path absorption detection. The LOD for aqueous hydrogen peroxide was 16 nM using a fluorescence method based on the formation of thiochrome from thiamine and 4 nM by a luminol chemiluminescence method. With a Nafion membrane diffusion scrubber (DS), the LOD was 8.0 pptv for gaseous hydrogen peroxide by the fluorescence method.  相似文献   

2.
Sun M  Du WB  Fang Q 《Talanta》2006,70(2):392-396
In this work, a miniaturized liquid-liquid extraction system under stopped-flow manipulation mode with spectrometric detection was developed. A Teflon AF liquid-core waveguide (LCW) capillary was used to serve as both extraction channel for organic solvent flow and adsorption detection flow cell. Gravity induced hydrostatic pressure was used to drive the organic and aqueous phases through the extraction channels. During extraction process, a stable organic and aqueous phase interface was formed at the outlet of the capillary, through which the analyte in the flowing aqueous stream was extracted into the stationary organic solvent in capillary. The absorbance of the analyte extracted into the organic solvent was measured in situ by a spectrometric detection system with light emitting diode (LED) as light source and photodiode as absorbance detector. The performance of the system was demonstrated in the determination of sodium dodecyl sulfate (SDS) extracted as an ion pair with methylene blue into chloroform. The precision of the measured absorbance for a 5 mg L−1 SDS standard was 6.1% R.S.D. (n = 5). A linear response range of 1-10 mg L−1 SDS was obtained with 5 min extraction period. The limit of detection (LOD) for SDS based on three times standard deviation of the blank response was 0.25 mg L−1.  相似文献   

3.
Direct analysis of free bilirubin in human and animal blood serum samples is reported for the first time. A state-of-the-art system comprised of newly developed high-performance liquid chromatography (HPLC) on reverse-phase (RP) C18 support coupled with thermal lens spectrometric detection (TLS), based on excitation at λ = 457.9 nm by an argon laser was used for this purpose. This HPLC-TLS method enabled a baseline separation of all three structural isomers of bilirubin (XIII-α, IX-α and III-α) and the respective degradation products in isocratic mode in fewer than 7 min. The method excels in ultra-high sensitivity with limit of detection (LOD) and limit of quantitation (LOQ) of 90 pM and 250 pM, respectively. Moreover, this method also affords high precision and accuracy, with correlation coefficients R2 > 0.997 over a broad linear range (0.250–150 nM) and R2 = 0.9998 in a concentration range of clinical interest (0.500–25 nM). The method's boosted sensitivity enabled to streamline sample preparation to just one serum ultrafiltration step, which made qualitative evaluation of sample preparation possible for the first time. The performance of the HPLC-TLS method was assessed to have 20-fold enhanced sensitivity when compared to a comparable method incorporating HPLC coupled with diode array detector (DAD), which is also a novel method by itself, and could be applied for free bilirubin determination in patients with elevated bilirubin levels.  相似文献   

4.
Multidimensional analysis of instant coffee and barley beverage samples using size exclusion chromatography (SEC) combined with a dynamic surface tension detector (DSTD) and a UV-vis absorbance detector (UV) is reported. A unique finding of this study was the action of the tetrabutylammonium (TBA) cation as a modifying agent (with bromide as the counter anion) that substantially increased the surface pressure signal and sensitivity of many of the proteins in the chromatographically separated samples. The tetrabutylammonium bromide (TBAB) enhancement of the surface pressure signal was further investigated by studying the response of 12 commercial standard proteins (α-lactalbumin, β-lactoglobulin, human serum albumin (HSA), albumin from chicken egg white (OVA), bovine serum albumin (BSA), hemoglobin, α-chymotrypsinogen A, cytochrome C, myoglobin, RNase A, carbonic anhydrase, and lysozyme) in buffer performed using flow injection analysis (FIA) coupled with the DSTD with and without various concentrations of TBAB. The FIA-DSTD data show that 1 mM TBAB enhances sensitivity of HSA detection, by lowering the limit of detection (LOD) from 2 mg/mL to 0.1 mg/mL. Similarly, the LOD for BSA was reduced from 1 mg/mL to 0.2 mg/mL. These FIA-DSTD experiments allowed the detection conditions to be optimized for further SEC-UV/DSTD experiments. Thus, the SEC-UV/DSTD system has been optimized and successfully applied to the selective analysis of surface-active protein fractions in a commercial instant coffee sample and in a soluble barley sample. The complementary selectivity of using the DSTD relative to an absorbance detector is also demonstrated.  相似文献   

5.
The absorbance characteristics and influential factors on these characteristics for a liquid-phase gas sensor, which is based on gas–permeable liquid core waveguides (LCWs), are studied from theoretical and experimental viewpoints in this paper. According to theory, it is predicted that absorbance is proportional to the analyte concentration, sampling time, analyte diffusion coefficient, and geometric factor of this device when the depletion layer of the analyte is ignored. The experimental results are in agreement with the theoretical hypothesis. According to the experimental results, absorbance is time-dependent and increasing linearly over time after the requisite response time with a linear correlation coefficient r2 > 0.999. In the linear region, the rate of absorbance change (RAC) indicates improved linearity with sample concentration and a relative higher sensitivity than instantaneous absorbance does. By using a core liquid that is more affinitive to the analyte, reducing wall thickness and the inner diameter of the tubing, or increasing sample flow rate limitedly, the response time can be decreased and the sensitivity can be increased. However, increasing the LCW length can only enhance sensitivity and has no effect on response time. For liquid phase detection, there is a maximum flow rate, and the absorbance will decrease beyond the stated limit. Under experimental conditions, hexane as the LCW core solvent, a tubing wall thickness of 0.1 mm, a length of 10 cm, and a flow rate of 12 mL min−1, the detection results for the aqueous benzene sample demonstrate a response time of 4 min. Additionally, the standard curve for the RAC versus concentration is RAC = 0.0267 c + 0.0351 (AU min−1), with r2 = 0.9922 within concentrations of 0.5–3.0 mg L−1. The relative error for 0.5 mg L−1 benzene (n = 6) is 7.4 ± 3.7%, and the LOD is 0.04 mg L−1. This research can provide theoretical and practical guides for liquid–phase gas sensor design and development based on a gas-permeable Teflon AF 2400 LCW.  相似文献   

6.
A method was developed to determine traces of trifluoroacetic acid as impurity in synthetic or semi-synthetic drugs as antibiotics, macropeptides, etc. Capillary electrophoresis in combination with capacitively coupled contactless conductivity detection (CE-C4D) was used due to lack of UV absorbance property of trifluoroacetic acid (TFA). The optimized method took less than 1 min with good linearity (R2 = 0.9995) for trifluoroacetic acid concentration from 2 to 100 ppm. It also has a good repeatability expressed by the relative standard deviation (% RSD) which is 1.2 and 2.1% for intraday and interday precision, respectively, at 50 ppm TFA, and good sensitivity with 0.34 ppm, 1.2 ppm LOD and LOQ, respectively. In addition, the content of TFA in synthetic drug, was determined using the validated method which gave good linearity (R2 = 0.9996) for trifluoroacetic acid spiked into drug in a concentration range of 2-80 ppm, with good intraday repeatability of 2.0%.The analysis is performed in a background electrolyte composed of 20 mM morpholinoethane-sulfonic acid (Mes) and 20 mM l-histidine (l-His) pH 6.1. Cetyltrimethylammonium bromide (CTAB) was added as flow modifier in a concentration (0.2 mM) lower than the critical micellar concentration. Ammonium formate 6 ppm was used as internal standard. The applied voltage was 30 kV in reverse polarity. A fused silica capillary with 75 μm internal diameter and total length 47 cm (31 cm to C4D detector and 37 cm to DAD detector) was used.  相似文献   

7.
Kynurenic acid (KYNA), an endogenous antagonist of ionotropic glutamate and α7 nicotinic receptors, was fluorometrically determined by column-switching high-performance liquid chromatography (HPLC) with fluorescence detection. The HPLC system consists of two octadecyl silica (ODS) columns, both of which are connected with an anion-exchange column (trapping column). Following sample injection onto the HPLC column, KYNA was separated on the first ODS column with a mobile phase of H2O/acetonitrile (95/5) containing 0.1% acetic acid. The peak fraction of KYNA was trapped on the anion-exchange column by changing the position of a six-port valve and then introduced into the second ODS column. Subsequently, KYNA was detected fluorometrically as a fluorescence complex formed with zinc ion which was pumped constantly. Instrumental limit of detection was approximately 0.16 nM, which corresponded to 8.0 fmol (per 50 μl injection, signal to noise ratio 3), and the limit of quantification was 0.53 nM (signal to noise ratio 10). Intra- and inter-day relative standard deviations were 1.1-3.9% (n = 3) and 3.0-5.3% (n = 3), respectively. The peak of KYNA in rat plasma was clearly detected by the proposed column-switching HPLC system after a facile pretreatment procedure. Intra- and inter-day relative mean errors were −1.6-1.4% (n = 3) and −2.4 to −0.4% (n = 3), respectively, with a satisfactory precision (within 5.0%). A calibration curve for the determination of KYNA showed a good linearity (r2 > 0.999) in the range of 25-200 nM. The KYNA concentrations in the plasma of male Sprague-Dawley rats (8-week-old) were 44 ± 5.5 nM (mean ± S.E., n = 5). In ketamine-treated rats, which are animal models of schizophrenia, the plasma KYNA concentrations were significantly increased compared with those in the control rats (p < 0.05).  相似文献   

8.
A flow injection manifold incorporating a 1 m liquid waveguide capillary cell and a miniature fibre-optic spectrometer for the determination of low phosphorus concentrations in natural waters is reported. The limit of detection (blank + 3 S.D.) was 10 nM using the molybdenum blue chemistry with tin(II) chloride reduction. The sensitivity of the flow injection manifold was improved by 100-fold compared with a conventional 1 cm flow cell. The response was measured at 710 nm and background corrected by subtracting the absorbance at 447 nm. Interference from silicate was effectively masked by the addition of 0.1% (m/v) tartaric acid and results were in good agreement (P = 0.05) with a segmented flow analyser reference method for freshwater samples containing 1 μM phosphate.  相似文献   

9.
A simple and sensitive liquid chromatographic method is described for the analysis of γ-amino-n-butyric acid (GABA) in human urine. GABA is increased in the urine of cancer patients and could be used as a biomarker in the diagnosis and treatment of related patients. The method is based on derivatizing GABA with a fluorescent reagent (naproxen acyl chloride) for transforming the non-chromophoric GABA to a derivative with chromophoric and fluorophoric properties. The resulting derivative is highly responsive to a fluorimetric detector (λex = 230 nm, λem = 350 nm). The lower quantitation of the method is attainable at 100 nM GABA with a detection limit about 10 nM (S/N = 3 with 20 μL injected). Application of the method to the analysis of GABA in the urine of patients with ovarian and uterine cancer was demonstrated.  相似文献   

10.
The potential of a recently developed lamp-based fluorescence detector for the analysis of underivatised proteins by capillary electrophoresis (CE) was investigated. Fluorescence detection (Flu) was achieved using optical light guides to deliver excitation light from a Xenon–Mercury lamp to the capillary detection window and to collect fluorescence emission and lead it to a photomultiplier. The performance of the detector was evaluated by monitoring the native fluorescence of the amino acid tryptophan and the proteins α-chymotrypsinogen A, carbonic anhydrase II, lysozyme and trypsinogen upon excitation at 280 nm. The test compounds were analysed using background electrolytes (BGEs) of sodium phosphate at pH 3.0 and 11.3. The results were compared to experiments of CE with UV absorbance detection. For tryptophan, a linear fluorescence response was obtained with a dynamic range of over 4 orders of magnitude, and a limit of detection (LOD) of 6.7 nM. This LOD was a factor of 200 more favourable than UV detection at 280 nm, and a factor of 20 better than detection at low-UV wavelengths. All tested proteins showed linear fluorescence responses up to 250 μg/mL. LODs were typically in the 10–20 nM range. These LODs were a factor of 25 lower than for UV detection at 280 nm, and comparable to UV detection at low-UV wavelengths. Overall, Flu yields much more stable baselines, especially with a BGE of high pH. The applicability of CE–Flu is demonstrated by the analysis of a degraded protein mixture, and of an expired formulation of the protein drug human growth hormone, indicating that protein degradation products can be selectively detected.  相似文献   

11.
In this paper, a novel detection reagent for formaldehyde determination is proposed, and is applied to a simple and highly sensitive flow injection method for the spectrophotometric determination of formaldehyde. The method is based on the reaction of formaldehyde with methyl acetoacetate in the presence of ammonia. The increase in the absorbance of the reaction product was measured at 375 nm. An inexpensive light emitting diode (LED)-based UV detector (375 nm) was, for the first time, used. Under the optimized experimental conditions, formaldehyde in an aqueous solution was determined over the concentration range from 0.25 to 20.0 × 10−6 M with a liner calibration graph; the limit of detection (LOD) of 5 × 10−8 M (1.5 μg L−1) was possible. The relative standard deviation of 12 replicate measurements of 5 × 10−6 M formaldehyde was 1.2%. Maximum sampling throughput was about 21 samples/h. The effect of potential interferences such as metals, organic compounds and other aldehyde was also examined. The analytical performance for formaldehyde determination was compared with those obtained by the conventional acetylacetone method, which uses visible absorption spectrophotometry. Finally, the proposed method was successfully applied to the determination of formaldehyde in natural water samples.  相似文献   

12.
A micropumping multicommutation manifold to perform turbidity determinations in waters is described. The procedure is based on the use of a combination of hydrazine sulfate and hexamethylenetetramine, to obtain an external standard of nephelometric turbidity units (NTU), which could compare the absorbance measurements at high wavelengths for samples with a calibration line obtained from a concentrated formazine standard diluted on-line. To minimize sample and reagent consumption and waste generation, the flow system was designed with two solenoid micro-pumps, one of them for the alternative introduction of the formazine standard and samples and the other one for the water carrier. The multicommutation approach makes possible the on-line dilution of a single standard to obtain the external calibration. The linear response was ranged up to 160 NTU. The coefficient of variation was estimated as 1.6 and 3.2% for 10 and 100 mm flow cell, respectively, for solutions containing 40 NTU (n = 10). Approximately, 60 determinations can be carried out per hour with limit of detection values of 1 and 0.1 NTU, consuming only 160 or 240 μL formazine solution and generating 1.8 or 2.0 mL waste per determination, using measurement cells of 10 and 100 mm optical pathlength, respectively. The procedure was successfully applied to 11 different water samples. Recovery studies were carried out and results obtained were between 97.5 ± 0.2 and 100 ± 1%. The development of a homebuilt light emitting diode (LED)-based portable flow analysis instrument was checked for in situ turbidimetric measurements, providing this equipment a LOD value of 0.09 NTU working with a blue LED at 464 nm and a LOD value of 0.1 NTU working with an IR LED.  相似文献   

13.
Zhang M  Zhang Z  Yuan D  Feng S  Liu B 《Talanta》2011,84(2):443-450
An automatic gas-phase molecular absorption spectrometric (GPMAS) system was developed and applied to determine nitrite and total nitrate in water samples. The GPMAS system was coupled with a UV-light emitting diode photodiode (UV-LED-PD) based photometric detector, including a 255 nm UV-LED as the light source, a polyvinyl chloride (PVC) tube of 14 cm as the gas flow cell, and an integrated photodiode amplifier to measure the transmitted light intensity. The UV-LED-PD detector was compact, robust, simple and of low heat production, comparing with detectors used in other GPMAS works. For nitrite measurement, citric acid was used to acidify the sample, and ethanol to catalyze the quantitative formation of NO2. The produced NO2 was purged with air flow into the UV-LED-PD detector, and the gaseous absorbance value was measured. The total nitrate could be determined after being reduced to nitrite with a cadmium column. Limits of detection for nitrite and nitrate were 7 μmol/L and 12 μmol/L, respectively; and linear ranges of 0.021-5 mmol/L for nitrite and 0.036-4 mmol/L for nitrate were obtained. Related standard deviations were 1.81% and 1.08% for nitrite and nitrate, respectively, both at 2 mmol/L. The proposed method has been applied to determine nitrite and total nitrate in some environmental water samples.  相似文献   

14.
A kinetic spectrophotometric procedure was developed for determination of submicromolar orthophosphate based on the reaction in which orthophosphate serves as a catalyst in the reduction of molybdenum, and the initial rate of molybdenum-blue formation (λmax = 780 nm) is proportional to the concentration of orthophosphate in the samples. The detection limit (3 × standard deviation of blank, n = 8) was 6 nM and the linear calibration ranged from 10 to 100 nM (r2 = 0.997). The precisions of this method were 3.3% at 10 nM and 5.4% at 50 nM (n = 8), respectively. Similar to other molybdate based methods, silica and arsenate in the samples can interfere with phosphate determination. The responses of silicate and arsenate were about 25% and 7% of that of orthophosphate, respectively, and their interferences were enhanced in the presence of phosphate in the samples due to the synergistic effect of phosphate with arsenate or silicate on the molybdate reagent.  相似文献   

15.
The use of a low pressure ion chromatograph based upon short (25 mm × 4.6 mm) surfactant coated monolithic columns and a low cost paired emitter-detector diode (PEDD) based detector, for the determination of alkaline earth metals in aqueous matrices is presented. The system was applied to the separation of magnesium, calcium, strontium and barium in less than 7 min using a 0.15 M KCl mobile phase at pH 3, with post-column reaction detection at 570 nm using o-cresolphthalein complexone. A comparison of the performance of the PEDD detector with a standard laboratory absorbance detector is shown, with limits of detection for magnesium and calcium using the low cost PEDD detector equal to 0.16 and 0.23 mg L−1, respectively. Finally, the developed system was used for the determination of calcium and magnesium in a commercial spring water sample.  相似文献   

16.
Jian Ma  Min Zhang  Ying Liang 《Talanta》2009,78(1):315-1104
A novel reverse flow injection analysis method coupled with a liquid waveguide capillary cell (LWCC) and spectrophotometric detection for the determination of nanomolar soluble reactive phosphorus in seawater was established. Reagent was injected into the sample stream and detected in a 2-m path length LWCC with detection wavelength set at 710 nm. Experimental parameters, including the reagent concentration, the injection volume, the flow rate and the length of the mixing coil, were optimized based on univariate experimental design. The interference of silicate and arsenate were also investigated. Under optimized conditions, the linearity and the detection limit of the proposed method were found to be 0-165.0 nM and 0.5 nM, which was estimated to be three times the standard deviation of the measurement blanks (n = 9). The relative standard deviations for the determination of 24.7 and 82.5 nM samples were 1.54% and 1.86% (n = 9), respectively. Three seawater samples were analyzed with recoveries ranging from 87.8% to 101.8%. Using the Student's t-test at the 95% confidence level, the results of the proposed method and a segmented flow analyzer reference method for determination of the two samples showed no significant difference. The proposed method had the advantages of being less reagent consuming, more sensitive and with higher throughput (15 h−1).  相似文献   

17.
A flow amperometric enzymatic biosensor for the determination of glucose was constructed. The biosensor consists of a flow reactor based on porous silver solid amalgam (AgSA) and a flow tubular detector based on compact AgSA. The preparation of the sensor and the determination of glucose occurred in three steps. First, a self-assembled monolayer of 11-mercaptoundecanoic acid (MUA) was formed at the porous surface of the reactor. Second, enzyme glucose oxidase (GOx) was covalently immobilized at MUA-layer using N-ethyl-N′-(3-dimethylaminopropyl) carboimide and N-hydroxysuccinimide chemistry. Finally, a decrease of oxygen concentration (directly proportional to the concentration of glucose) during enzymatic reaction was amperometrically measured on the tubular detector under flow injection conditions. The following parameters of glucose determination were optimized with respect to amperometric response: composition of the mobile phase, its concentration, the potential of detection and the flow rate. The calibration curve of glucose was linear in the concentration range of 0.02–0.80 mmol L−1 with detection limit of 0.01 mmol L−1. The content of glucose in the sample of honey was determined as 35.5 ± 1.0 mass % (number of the repeated measurements n = 7; standard deviation SD = 1.2%; relative standard deviation RSD = 3.2%) which corresponds well with the declared values. The tested biosensor proved good long-term stability (77% of the current response of glucose was retained after 35 days).  相似文献   

18.
A novel on-line HPLC-DTNB method was developed for the selective determination of biologically important thiols (biothiols) such as l-cysteine (Cys), glutathione (GSH), homocysteine (HCys), N-acetylcysteine (NAC), and 1,4-dithioerythritol (DTE) in pharmaceuticals and tissue homogenates. The biothiols were separated on C18 column using gradient elution, reacted with the postcolumn reagent, DTNB in 0.5% M-β-CD (w/v) solution at pH 8, to form yellow-colored 5-thio-2-nitrobenzoic acid (TNB), and monitored with a PDA detector (λ = 410 nm). With the optimized conditions for chromatography and the post-column derivatization, 40 nM of NAC, 40 nM of Cys, and 50 nM of GSH can be determined. The relative standard deviations of the recommended method were in the range of 3.2–5.4% for 50 μM biothiols. The negative peaks of biothiol constituents were monitored by measuring the increase in absorbance due to TNB chromophore. The detection limits of biothiols at 410 nm (in the range of 0.04–0.58 μM) after post-column derivatization with DTNB + M-β-CD were much lower than those at 205 nm UV-detection without derivatization, and were distinctly lower than those with post-column DTNB alone. The method is rapid, inexpensive, versatile, nonlaborious, uses stable reagents, and enables the on-line qualitative and quantitative estimation of biothiol constituents of biological fluids and pharmaceuticals.  相似文献   

19.
We describe a light emitting diode (LED) based multi-reflection capillary scale absorbance detector based on both square and round capillaries and compare their performance with a conventional single-pass on-tube detector. The optical path length is extended by silver coating, the external surface of the capillary. The reflective geometry has been reported to be less prone to artifacts induced by refractive index changes; we do find this to be true. Although the detection volume/illuminated volume is increased some, a multi-reflection cell based on a 180 μm bore capillary with a ∼2-cm long illuminated volume shows over a 50-fold gain in signal-to-noise (S/N) compared to a single-pass on-tube configuration with the same capillary. The limit of detection (LOD) is 4.4 fmol (2.6 pg, 1 μL of 22.0 nM injected dye) BTB under pulseless (pneumatic) flow conditions. The cells behave as multipath devices where the effective path lengths are greater at low absorbance values. In our experiments, where non-coherent light is launched through optical fibers that are large compared to capillary bore dimensions, increase in the effective path length of the cell do not occur in a predictable fashion with the angle of incidence of the light beam. Although the effective path length almost linearly increases with increasing distance between the light entry and exit windows, the absolute values of the effective path lengths are always lower than this physical distance, suggesting that after some passage through the solution, light largely travels through or along the glass wall. Square capillaries have better light transmission and offer some performance advantages. Multi-reflection cells can indeed be of value for sensitive detection in microflow systems.  相似文献   

20.
A mass spectrometric (MS) method for the identification of iron protoporphyrin (IX) (FePTP, heme b) in marine particulate material and phytoplankton is described. Electrospray ionisation of FePTP produced the molecular Fe(III)PTP+ ion (m/z = 616) or the pseudomolecular [Fe(II)PTP + H]+ ion (m/= 617), depending on the oxidation state of the central iron ion. Collision induced dissociation (CID) in the ion trap mass spectrometer resulted in a single detected product ion (m/z = 557) indicative of loss of ethanoic acid from a carboxylic acid side chain. Widening the isolation width to 616 ± 3 resulted in production of a mass spectrum demonstrating the distinctive isotopic ratio of the iron containing fragment, further increasing the specificity of the analysis. Selective reactant monitoring (SRM) of the fragment ion (m/z = 557) was applied to the detection of FePTP after chromatography of ammoniacal OGP extracts of marine samples. The detection limit for FePTP analysed by SRM after chromatography was 1.2 ± 0.5 fmol. For phytoplankton samples, reasonably good agreement was achieved between results obtained with SRM and those obtained by monitoring absorbance at λ = 400 nm using a diode array detector (DAD). Use of SRM for analysis of particulate material obtained from the high latitude North Atlantic allowed for the analysis of FePTP in the presence of a co-eluting compound that interfered with detection by DAD. Simultaneous collection of mass spectra from m/z = 300 to 1500 resulted in identification of the pseudomolecular ion for the interfering compound. The CID fragmentation pattern and UV–visible mass spectra indicated that the interfering compound was a previously unidentified chlorin type compound. Comparison of FePTP determined by SRM and DAD on samples where this compound could not be detected showed that results collected using the two methods correlated. The use of both MS and DAD results in a powerful tool for quantifying this important biogenic component of the particulate iron pool.  相似文献   