首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Summary A new EGA-MS instrument consisted of a combination of skimmer interface with no change of evolved gaseous species and IAMS (Ion Attachment Mass Spectrometry) with no fragmentation during the ionization has been developed successfully. As its application of evolved gaseous species from PVA as firing process of alumina ceramics binder, the method has indicated detection of gaseous species which have not been detected with Py-GC-MS.  相似文献   

2.
Tsugoshi T  Nakagi S  Ohashi F  Watari K 《Talanta》2006,70(1):182-185
An application of evolved gas analysis-mass spectrometry (EGA-MS) with skimmer interface was carried out to investigate the pyrolysis mechanism of an antibacterial and antifungal material that is expected with thermostability. The skimmer interface between a furnace and a vacuum chamber with a mass spectrometer transmitted the gaseous species, which were trapped by a general capillary interface. As a result, it became clear that the thermostability of antimicrobial activity was limited by the heat resistance of the coordinate bond between nitrogen and silver in the silver chelate.  相似文献   

3.
Materazzi S  Gentili A  Curini R 《Talanta》2006,69(4):781-794
The analytical applications of the evolved gas analysis (EGA) performed by mass spectrometry, for the period extending from 2001 to 2004, are collected in this review. By this technique, the nature of volatile products released by a substance subjected to a controlled temperature program is on-line determined, with the possibility to prove a supposed reaction, either under isothermal or under heating conditions.  相似文献   

4.
A gas chromatography with ion trap mass spectrometry method has been developed and validated for the analysis of 27 polar organic compounds in atmospheric aerosols. The target analytes were low‐molecular‐weight carboxylic acids and methoxyphenols, as relevant markers of source emissions and photochemical processes of organic aerosols. The operative parameters were optimized in order to achieve the best sensitivity and selectivity for the analysis. In comparison with the previous gas chromatography with mass spectrometry procedure based on single ion monitoring detection, the tandem mass spectrometry technique increased the analytical sensitivity by reducing detection limits for standard solutions from 1–2.6 to 0.1–0.4 ng/μL ranges (concentrations in the injected solution). In addition, it enhanced selectivity by reducing matrix interferences and chemical noise in the chromatogram. The applicability of the developed method in air quality monitoring campaigns was effectively checked by analyzing environmental samples collected in the Po Valley (Northern Italy) in different seasons. The obtained results indicate that the ion trap mass spectrometer may be an ideal alternative to high‐resolution mass spectrometers for the user‐friendly and cost‐effective determination of a wide range of molecular tracers in airborne particulate matter.  相似文献   

5.
A variety of crude oil samples have been investigated by the combined methods of thermal analysis and mass spectrometry by means of a newly developed prototype of a thermogravimetry—single photon ionisation time-of-flight mass spectrometer coupling (TG-SPI-TOFMS). Single photon ionisation (SPI) was conducted utilising a novel electron beam pumped argon excimer lamp (EBEL) as photon source, and a TOFMS with orthogonal acceleration has been applied for the detection of the mass to charge signals. The advantage of the soft SPI technique over EI for the analysis of such complex samples could be clearly demonstrated, as the aliphatic hydrocarbons present in crude oil may be detected via their respective molecular ion signals, not showing the intense fragmentation typical for EI spectra of this substance class. The application of SPI revealed furthermore two distinct decomposition regions, dominated by evaporation and pyrolysis processes, respectively. Moreover, different crude oils could be distinguished by TA/SPI mass spectra due to their unique molecular signatures.  相似文献   

6.
Radiofrequency (RF) millisecond pulsed glow discharge (PGD) coupled to time-of-flight mass spectrometry (TOFMS) was investigated for direct elemental analysis of glass samples. Aiming at achieving highest elemental sensitivity, appropriate discrimination from polyatomics, and good crater shapes on glasses, a new Grimm-type GD chamber (termed from now “UNIOVI GD”, designed and constructed in our laboratory) was coupled to TOFMS, and the results compared with those obtained with the former GD design (here denominated as “GD.1”) of the initial RF-PGD-TOFMS prototype. The critical differences distinguishing the two GDs under scrutiny are the GD chamber thickness (15.5 mm for the GD.1 and 7 mm for the UNIOVI GD) and the “flow tube” which is inserted in the GD.1 and inexistent in UNIOVI GD.  相似文献   

7.
Polyoxyethyleneglycerol triricinoleate 35 (Cremophor EL: CrEL) is a solubilization agent for hydrophobic drugs. Recently, CrEL has shown some side effects in patients. In the present work, we introduce pyrolysis-mass spectrometry (Py-MS) for the determination of CrEL in drugs and blood samples. Mass to charge (m/z) values of 89 and 138 of CrEL and 3-nitroaniline (as internal standard), respectively, were used for quantitative measurements by selected ion monitoring (SIM) method. At a probe pyrolysis temperature range of 350-450 °C the results are highly reproducible. Limit of detection (LOD), linearity and relative standard deviation (R.S.D., n=5) were determined to be 1 ng ml−1, 10 ng ml−1-100 mg ml−1 and 1.3%, respectively. The results of Py-MS are compared with those obtained by high performance liquid chromatography (HPLC) and show that time for analysis, sensitivity and linearity are far better.  相似文献   

8.
Malavia J  Santos FJ  Galceran MT 《Talanta》2011,84(4):574-1162
This paper describes a fast and simple pressurized liquid extraction (PLE) method combined with gas chromatography coupled to ion trap tandem mass spectrometry (GC-ITMS-MS) for the determination of polybrominated biphenyls (PBBs) in fish samples. The method is based on a simultaneous extraction/clean-up step to reduce analysis time and solvent consumption. The effect of several PLE operating conditions, such as solvent type, extraction temperature and time, number of cycles, and lipid retainer, was optimized to obtain maximum recovery of the analytes with the minimum presence of matrix-interfering compounds. The best conditions were obtained at 100 °C with n-hexane using 15 g of silica modified with sulphuric acid (44%, w/w) as sorbent for lipid removal. Quality parameters of the GC-ITMS-MS method were established, achieving good linearity (r > 0.998), between 1 and 500 ng ml−1, and low instrumental limits of detection (0.14-0.76 pg injected). For the whole method, limits of detection ranging from 0.03 to 0.16 ng g−1 wet weight and good precision (RSD < 16%) were obtained.  相似文献   

9.
采用顶空固相微萃取和气相色谱 质谱单离子监测技术,以己二酸二(1 丁基戊基)酯为内标,对水中的己二酸二乙酯、己二酸二异丁酯、己二酸二丁酯、己二酸二(2 丁氧基乙基)酯、己二酸二(乙基己基)酯进行了测定,考察了盐效应、萃取温度、萃取时间和热解吸时间等因素对方法灵敏度的影响。该方法对5种己二酸酯的检测限量为0.0220~5.49μg L,回收率为86.9%~102.0%,相对标准偏差为1.5%~7.3%。  相似文献   

10.
Selected tandem mass spectrometry (MS/MS) ion monitoring (SMIM) is the most suitable scanning mode to detect known peptides in complex samples when an ion-trap mass spectrometer is the instrument used for the analysis. In this mode, the MS detector is programmed to perform continuous MS/MS scans on one or more selected precursors, either during a selected time interval, or along the whole chromatographic run. MS/MS spectra are recorded, so virtual multiple reaction monitoring chromatogram traces for the different fragment ions can be plotted. In this work, a shotgun proteomics approach was applied to the detection of previously characterized species-specific peptides from different seafood species. The proposed methodology makes use of high intensity focused ultrasound-assisted trypsin digestion for ultra fast sample preparation, peptide separation and identification by reverse phase capillary LC coupled to an ion-trap working in the SMIM scanning mode. This methodology was applied to the differential classification of seven commercial, closely related, species of Decapoda shrimps proving to be an excellent tool for seafood product authentication, which may be used by fisheries and manufacturers to provide a fast and effective identification of the specimens, guaranteeing the quality and safety of foodstuffs to consumers.  相似文献   

11.
A high-field asymmetric waveform ion mobility spectrometry (FAIMS)-based method for the determination of the mycotoxin zearalenone (ZON) and its metabolites α-zearalenol (α-ZOL), β-zearalenol (β-ZOL), and β-zearalanol (β-ZAL), in a cornmeal (maize) matrix is described. Detection limits achieved using the FAIMS device coupled with electrospray ionization (ESI) and mass spectrometric (MS) detection are 0.4 ng mL−1 for ZON and 3 ng mL−1 for α-ZOL + β-ZOL, and β-ZAL. This represents a significant improvement when compared to detection limits determined using ESI-MS or ESI-tandem mass spectrometry (MSMS) analytical methods. The developed flow-injection (FIA)-ESI-FAIMS-MS method was applied to reference materials ERM-BC-716 and ERM-BC-717 certified for ZON and excellent agreement with the certified values was observed.  相似文献   

12.
The different parameters affecting the ionisation and fragmentation of selected polychlorinated biphenyls (PCBs) in an IT detector working in the MS/MS mode, ITD(MS/MS), have been optimised for maximum selectivity and sensibility. The low LODs (in the range 0.03-0.3 microg/L), the satisfactory repeatability (RSDs in general below 11%) and reproducibility (RSDs below 17%) obtained when analysing standard solutions ensured proper determination of the PCBs studied at the concentrations typically found in food samples. Foodstuffs naturally contaminated with varying levels of PCBs have been analysed using the optimised GC-ITD(MS/MS) method. The results obtained compared favourably with those found using more conventional detectors, such as (micro-)electron capture detection (for ortho-PCBs) and high-resolution MS (for non-ortho-PCBs), as well as with the consensus PCB levels established for these particular samples via an international interlaboratory exercise. The relative merits of these three detectors have been discussed.  相似文献   

13.
Secondary electrospray ionization-ion mobility-time of flight mass spectrometry (SESI-IM-TOFMS) was used to evaluate common household products and food ingredients for any mass or mobility responses that produced false positives for explosives. These products contained ingredients which shared the same mass and mobility drift time ranges as the analyte ions for common explosives. The results of this study showed that the vast array of compounds in these products can cause either mass or mobility false positive responses. This work also found that two ingredients caused either enhanced or reduced ionization of the target analytes. Another result showed that an IMS can provide real-time separation of ion species that impede accurate mass identifications due to overlapping isotope peak patterns. The final result of this study showed that, when mass and mobility values were used to identify an ion, no false responses were found for the target explosives. The wider implication of these results is that the possibility exists for even greater occurrences of false responses from complex mixtures found in common products. Neither IMS nor MS alone can provide 100% assurance from false responses. IMS, due to its low cost, ease of operation, rugged reliability, high sensitivity and tunable selectivity, will remain the field method of choice for the near future but, when combined with MS, can also reduce the false positive rate for explosive analyses.  相似文献   

14.
José Robles-Molina 《Talanta》2010,82(4):1318-1324
In this work, we report the development and validation of an analytical method for the trace level determination of 14 selected (EU-directive) priority organic pollutants (namely, 1,2,3-trichlorobenzene (1,2,3-TCB), 1,2,4-trichlorobenzene, 1,3,5-trichlorobenzene, hexachloro-1,3-butadiene, pentachlorobenzene, hexachlorobenzene, alachlor, α-hexachloro-cyclohexane (α-HCH), β-HCH, γ-HCH (lindane), δ-HCH, tetra-brominated diphenyl ether (tetra-BDE), penta-brominated diphenyl ether and hepta-brominated diphenyl ether) in wastewater samples from 5 different sewage treatment plants (STPs) located in Spain. The proposed methodology is based on liquid-liquid extraction with n-hexane followed by identification and confirmation of the selected pollutants by gas chromatography high-resolution mass spectrometry in selected ion recording acquisition mode. Recovery studies performed with spiked wastewater samples at two different concentration levels (0.1 and 1 μg L−1) gave mean recoveries in the range 80-120% (except for trichlorobenzenes, ca. with 50%) with RSD values below 10% in most cases, thus confirming the usefulness of the proposed methodology for the analyses of this kind of complex samples. The obtained detection limits in effluent wastewater matrices were in the low nanogram per liter range, with values as low as 0.09 ng L−1 for tetra-BDE and 0.3 ng L−1 for hexachlorobenzene. Finally, the proposed methodology was successfully applied to a monitoring study intended to characterize wastewater effluents of 5 different sewage treatment plants with different major activities (Industrial, Coastal, Urban). Most of the compounds targeted were detected in the ng L−1 range at concentrations ranging from 0.19 ng L−1 to 135 ng L−1 (hexachlorobenzene).  相似文献   

15.
There has recently been increased interest in coupling ion chromatography (IC) to high resolution mass spectrometry (HRMS) to enable highly sensitive and selective analysis. Herein, the first comprehensive study focusing on the direct coupling of suppressed IC to HRMS without the need for post-suppressor organic solvent modification is presented. Chromatographic selectivity and added HRMS sensitivity offered by organic solvent-modified IC eluents on a modern hyper-crosslinked polymeric anion-exchange resin (IonPac AS18) are shown using isocratic eluents containing 5–50 mM hydroxide with 0–80% methanol or acetonitrile for a range of low molecular weight anions (<165 Da). Comprehensive experiments on IC thermodynamics over a temperature range between 20–45 °C with the eluent containing up to 60% of acetonitrile or methanol revealed markedly different retention behaviour and selectivity for the selected analytes on the same polymer based ion-exchange resin. Optimised sensitivity with HRMS was achieved with as low as 30–40% organic eluent content. Analytical performance characteristics are presented and compared with other IC-MS based works. This study also presents the first application of IC-HRMS to forensic detection of trace low-order anionic explosive residues in latent human fingermarks.  相似文献   

16.
Sung YH  Li TY  Huang SD 《Talanta》2005,65(2):518-524
A method for the determination of the earthy and musty odors geosmin, 2-methylisoborneol (2-MIB), 2-isobutyl-3-methoxy pyrazine (IBMP), 2-isopropyl-3-methoxy pyrazine (IPMP) and 2,4,6-trichloroanisole (2,4,6-TCA) in water by headspace solid-phase microextraction (HSSPME) combined with gas chromatography-ion trap mass spectrometry (GC-ITMS) is described. Several parameters of the extraction and desorption procedure were studied and optimized (such as types of fibers, extraction temperature, extraction time, desorption temperature, desorption time, ionic strength and elutropic strength and pH of samples). The method shows good linearity over the concentration range 1-500 ng l−1 and gives detection limits of sub-part per trillion levels for all compounds. Good precision (5.9-9.8%) is obtained using IBMP as internal standard. Finally, the method was successfully applied to analyze earthy and musty odors in tap water and lake water.  相似文献   

17.
A sensitive and specific method for the determination of memantine in human plasma is presented. Memantine was extracted from plasma and derivatized to the pentafluorobenzoyl derivative in a one-step procedure avoiding any sample concentration steps. Amantadine was used as an internal standard. The compounds were measured by gas chromatography/negative ion chemical ionization mass spectrometry without any further processing. Using this detection mode, the fragment ions at m/z 353 and 325 were obtained at high relative abundance. Calibration graphs were linear over the range 0.117-30 ng ml(-1). At the limit of quantification (LOQ), the inter-assay precision was 2.00% and the intra-assay variability was 3.22%. The accuracy at the LOQ showed deviations of -1.42% (intra-assay) and -2.47% (inter-assay). The method is rugged, rapid and robust and was applied to the batch determination of memantine during pharmacokinetic profiling of the drug.  相似文献   

18.
Three liquid chromatography-electrospray ionisation (LC-ESI) MS systems are evaluated for the analysis of heterocyclic amines (HAs). The electrospray sources and analysers (ion trap, single quadrupole and triple quadrupole) have been compared in terms of performance and quality parameters. In all cases, a C8 reversed-phase column and (acetic acid-ammonium acetate 30 mM pH 4.5)-acetonitrile (ACN) as mobile phase were used. Ionisation source parameters, post-column addition and working conditions for each acquisition mode (full scan, product ion scan, selected ion monitoring, and multiple reaction monitoring) were optimised for each instrument. The MS-MS spectra obtained with the ion trap and the triple quadrupole systems were very similar in both fragment ions and relative abundances, except for carbolines that showed adduct formation in the ion trap. Quality parameters were established and good precision (relative standard deviations (R.S.D.) < 12%) and very low limits of detection were obtained, mainly when using the triple quadrupole (< 9 pg injected). The content of HAs in a lyophilised beef extract was determined using the three instruments in order to compare their applicability for routine HAs analysis.  相似文献   

19.
We report a pyrolysis GC–MS method capable of analysing Indigenous Australian and European binders typically used in the manufacture of culturally important painted works. Eleven different traditional European binders and ten different Indigenous Australian binders were examined. The method allows discrimination between highly complex and impure lipid, resin, polysaccharide, wax, and protein-based binders. Each was found to have characteristic pyrolysis products that were unique to the binder material, demonstrating the potential for differentiation of these binders on Australian Aboriginal artworks towards identification and conservation of cultural heritage.  相似文献   

20.
Rechargeable nickel-metalhydride (NiMH) batteries have major advantages with respect to environmental friendliness and energy density compared to other battery systems. Research on thermodynamics and reaction kinetics is required to study the behaviour of these batteries, especially under severe operating conditions such as overcharging and (over)discharging. During these processes several reactions take place resulting in the formation of oxygen and hydrogen gas. Hence, the recombination processes should be well controlled to guarantee that the partial oxygen and hydrogen pressure inside the battery are kept low.Mass spectrometry is one of the analytical techniques capable of measuring the composition of gases released inside the battery during the charge and discharge processes. However, the sample gas needs to be withdrawn from the battery during the experiment. The gas consumption must be kept to a minimum otherwise the equilibrium inside the battery will be disturbed. A bench-top quadrupole mass spectrometer with a standard capillary by-pass inlet cannot be used for this purpose as its gas consumption is in the 1-10 ml/min range. In this paper, a new gas inlet device is presented that reduces gas consumption to a value <50 μl/h. The use of a capillary by-pass splitter and a discontinuous sampling procedure allow mass spectrometry to be used as a gas analysis tool in many applications in which small amounts of sample gas are involved.Experiments with standard AA-size NiMH batteries show that hydrogen release dominates during (over)charging at increased charging rates. Beside mass spectrometry, evolved gases are also analysed using Raman spectroscopy. Although some differences are observed, the results of similar experiments show a good agreement.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号