首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 265 毫秒
1.
《Analytical letters》2012,45(9):2025-2038
Abstract

A simple and highly sensitive method to quantify the rates of production of phenoxyl radicals in enzyme reaction is described. This method employs the peroxidase‐catalyzed reaction between chlorophenols and hydroperoxide to generate phenoxyl free radicals, which can enhance dimerization of L‐tyrosine. The product, dityrosine, was monitored fluorometrically at the excitation/emission wavelength of 320/410 nm and the initial rate of accelerated‐accumulation of dityrosine represents the formation rate of phenoxyl free radicals. With this method, the phenoxyl radicals generated in oxidation of chlorophenols with hydrogen peroxide, catalyzed by horseradish peroxidase, were investigated. Phenoxyl radicals generated from as low as 5.0×10?9 M 2,4‐dichlorophenol, for example, can be readily detected with a relative standard deviation of 2.6% for 9 replicated determination. The detection limits of phenoxyl radicals produced by various chlorophenols are 4.2×10?9, 1.1×10?9, 1.0×10?10, 2.8×10?8, and 1.1×10?7 M for 2‐chlorophenol, 4‐chlorophenol, 2,4‐dichlorophenol, 2,4,6‐trichlorophenol, and 2,3,4,6‐tetrachlorophenol, respectively. The possible pathway of the reaction is proposed. The protocol is suitable for quantification of free radicals in enzyme reaction and shows promise in being applied to biological systems.  相似文献   

2.
A new method, stir bar sorptive extraction (SBSE) with in situ derivatization and thermal desorption (TD)-gas chromatography-mass spectrometry (GC-MS), which is used for the determination of trace amounts of chlorophenols, such as 2,4-dichlorophenol (2,4-DCP), 2,4,6-trichlorophenol (2,4,6-TrCP), 2,3,4,6-tetrachlorophenol (2,3,4,6-TeCP) and pentachlorophenol (PCP), in tap water, river water and human urine samples, is described. The derivatization conditions with acetic acid anhydride and the SBSE conditions such as extraction time are investigated. Then, the stir bar is subjected to TD followed by GC-MS. The detection limits of the chlorophenols in tap water, river water and human urine samples are 1-2, 1-2, and 10-20 pg ml−1 (ppt), respectively. The calibration curves for the chlorophenols are linear and have correlation coefficients higher than 0.99. The average recoveries of the chlorophenols in all the samples are higher than 95% (R.S.D. < 10%) with correction using added surrogate standards, 2,4-dichlorophenol-d5, 2,4,6-trichlorophenol-13C6, 2,3,4,6-tetrachlorophenol-13C6 and pentachlorophenol-13C6. This simple, accurate, sensitive and selective analytical method may be applicable to the determination of trace amounts of chlorophenols in liquid samples.  相似文献   

3.
In this work, a very sensitive and simple electrochemical sensor for chlorophenols (CPs) based on a nanocomposite of cetyltrimethylammonium bromide (CTAB) and ZnSe quantum dots (ZnSe–CTAB) through electrostatic self-assembly technology was built for the first time. The composite of ZnSe–CTAB introduced a favorable access for the electron transfer and gave superior electrocatalytic activity for the oxidation of CPs than ZnSe QDs and CTAB alone. Differential pulse voltammetry (DPV) was used for the quantitative determination of the CPs including 2-chlorophenol (2-CP), 2,4-dichlorophenol (2,4-DCP) and pentachlorophenol (PCP). Under the optimum conditions, the peak currents of the CPs were proportional to their concentrations in the range from 0.02 to 10.0 μM for 2-CP, 0.006 to 9.0 μM for 2,4-DCP, and 0.06 to 8.0 for PCP. The detection limits were 0.008 μM for 2-CP, 0.002 μM for 2,4-DCP, and 0.01 μM for PCP, respectively. The method was successfully applied for the determination of CPs in waste water with satisfactory recoveries. This ZnSe–CTAB electrode system provides operational access to design environment-friendly CPs sensors.  相似文献   

4.
A new microextraction technique based on ionic liquid solid-phase microextraction (IL-SPME) was developed for determination of trace chlorophenols (CPs) in landfill leachate. The synthesized ionic liquid, 1-butyl-3-methylimidazolium hexafluorophosphate ([C4MIM][PF6]), was coated onto the spent fiber of SPME for extraction of trace CPs. After extraction, the absorbed analytes were desorbed and quantified using gas chromatography–mass spectrometry (GC/MS). The term of the proposed method is as ionic liquid-coated of solid-phase microextraction combined with gas chromatography–mass spectrometry (IL-SPME-GC/MS). No carryover effect was found, and every laboratory-made ionic liquids-coated-fiber could be used for extraction at least eighty times without degradation of efficiency. The chlorophenols studied were 2,4-dichlorophenol (2,4-DP), 2,4,6-trichlorophenol (2,4,6-TCP), 2,3,4,6-tetrachlorophenol (2,3,4,6-TeCP), and pentachlorophenol (PCP). The best results of chlorophenols analysis were obtained with landfill leachate at pH 2, headspace extraction for 4 min, and thermal desorption with the gas chromatograph injector at 240 °C for 4 min. Linearity was observed from 0.1 to 1000 μg L−1 with relative standard deviations (RSD) less than 7% and recoveries were over 87%. The limit of detection (LOD) for pentachlorophenol was 0.008 μg L−1. The proposed method was tested by analyzing landfill leachate from a sewage farm. The concentrations of chlorophenols were detected to range from 1.1 to 1.4 μg L−1. The results demonstrate that the IL-SPME-GC/MS method is highly effective in analyzing trace chlorophenols in landfill leachate.  相似文献   

5.
Summary A sensitive, specific and analytically reliable method for the determination of mono-, di-, tri- and tetrachlorophenols in human urine has been elaborated. After acid hydrolysis and a simultaneous steam distillation of the urine samples, spiked with an internal standard, the chromatographically concentrated chlorophenols have been derivatized with pentafluorobenzoylchloride and analyzed by capillary gas chromatography/mass spectrometry. The detection limits for the chlorophenols ranged from 0.2 to 2.5 g/l. Using this method we were able to detect 4-MCP, 2,4-+2,5-DCP, 2,4,6-TCP, 2,4,5-TCP and 2,3,4,6-+2,3,5,6-TeCP in urine samples of a group of 258 men and women which had no known occupational contact to hazardous chemical substances. The 95 percentiles for the concentrations of these substances in the urine samples under investigation were 7.5 (4-MCP); 33.6(2,4-+2,5-DCP); 4,7 (2,4,6-TCP); 4,5 (2,4,5-TCP) and 22.2 (2,3,4,6-+2,3,5,6-TeCP) g per liter. That means, that these chlorophenols are constituents of urine of the normal population in concentrations which in part are greater than that of pentachlorophenol (PCP).  相似文献   

6.
In this work an analytical procedure based on headspace solid-phase microextraction and gas chromatography coupled with mass spectrometry (HS-SPME–GC/MS) is proposed to determine chlorophenols with prior derivatization step to improve analyte volatility and therefore the decision limit (CCα). After optimization, the analytical procedure was applied to analyze river water samples. The following analytes are studied: 2,4-dichlorophenol (2,4-DCP), 2,4,6-trichlorophenol (2,4,6-TrCP), 2,3,4,6-tetrachlorophenol (2,4,6-TeCP) and pentachlorophenol (PCP). A D-optimal design is used to study the parameters affecting the HS-SPME process and the derivatization step. Four experimental factors at two levels and one factor at three levels were considered: (i) equilibrium/extraction temperature, (ii) extraction time, (iii) sample volume, (iv) agitation time and (v) equilibrium time. In addition two interactions between four of them were considered. The D-optimal design enables the reduction of the number of experiments from 48 to 18 while maintaining enough precision in the estimation of the effects. As every analysis took 1 h, the design is blocked in 2 days.  相似文献   

7.
Liu J  Niu J  Yin L  Jiang F 《The Analyst》2011,136(22):4802-4808
A biosensor based on Trametes versicolor laccase (Lac) was developed for the determination of phenolic compounds. The biosensor was prepared by in situ electrospinning of a mixture of polyvinyl alcohol (PVA), Lac, PEO-PPO-PEO (F108) and gold nanoparticles (Au NPs), where F108 was used as an enzyme stabilizing additive and Au NPs was used to enhance the conductivity of the biosensor. Laser confocal scanning microscopy and electrochemical impedance spectroscopy proved that the enzyme was successfully encapsulated into the electrospun nanofibers. Under the optimal conditions, the lowest detection limit was found to be 0.04 μM (S/N = 3) for 2,4-DCP and the highest detection limit was found to be 12.10 μM for 4-CP. The sensitivity of the biosensor obtained in the linear range for chlorophenols followed the sequence 2,4-dichlorophenol (2,4-DCP) > 2,4,6-trichlorophenol (2,4,6-TCP) > 4-chlorophenol (4-CP). The sensing performance for chlorophenols was attributed to the suitable electrochemical interface of PVA/F108/Au NPs/Lac, resulting from biocompatibility, a high surface area-to-volume ratio (10.42 m(2) g(-1)) and superior mechanical properties of the electrospun nanofibers. The biosensor exhibited good repeatabilities of 7.6%, 2.8% and 9.0% (R.S.D.) and reproducibilities of 14.9%, 10.4% and 13.7% (R.S.D.) for 4-CP, 2,4-DCP and 2,4,6-TCP, respectively. Lac retained 65.8% of its initial activity after a 30-day storage period.  相似文献   

8.
The chlorination of poly(vinyl chloride) (PVC) was investigated by means of low-molecular-weight models of PVC—a dimer and trimer of PVC, viz., 2,4-dichloropentane (2,4-DCP) and 2,4,6-trichloroheptane (2,4,67-TCH). Chlorinations of stereoisomeric mixtures of 2,4-DCP and 2,4,6-TCH have revealed that the d,1 form of 2,4-DCP (syndio-2,4-DCP) is more reactive in the chlorination than the meso form of 2,4-DCP (iso-2,4-DCP), while in the case of the chlorination of 2,4,6-TCH the reactivity of stereoisomers decreases in the order iso-> hetero->syndio-2,4,6-TCH; consequently, analogous structures of stereoisomers of 2,4-DCP and 2,4,6-TCH react in a reverse order and not in the same one. The qualitative order of reactivities of stereoisomers may be correlated formally with the magnitude of their dipole moments. The reactivity of stereoisomers of 2,4-DCP and 2,4,6-TCH decreases with increasing dipole moment.  相似文献   

9.
The binding interactions of lysozyme with 2-chlorophenol, 2,4-dichlorophenol, 2,4,6-trichlorophenol and pentachlorophenol were investigated by UV-vis absorption, CD, fluorescence, synchronous fluorescence, and three-dimensional fluorescence spectra techniques under physiological pH 7.40. The binding constants, quenching mechanism, and the number of binding sites were determined by the quenching of lysozyme fluorescence in presence of chlorophenols. H-bonds and hydrophobic interactions played major roles in stabilizing the chlorophenols-lysozyme complex. The distances r between chlorophenols and lysozyme were calculated to be 1.94nm, 2.75nm, 3.54nm, and 3.76nm for 2-CP, 2,4-DCP, 2,4,6-TCP, and PCP, respectively. The effects of chlorophenols on the conformation of lysozyme were analyzed using CD, synchronous fluorescence and three-dimensional fluorescence spectra.  相似文献   

10.
The 1-octyl-3-methylimidazolium hexafluorophosphate ([C8MIM][PF6]) ionic liquid was immobilized in the pores of a polypropylene hollow fiber for hollow fiber-protected liquid-phase microextraction. Analytes including 4-chlorophenol (4-CP), 3-chorophenol (3-CP), 2,4-dichlorophenol (2,4-DCP) and 2,4,6-trichlorophenol (2,4,6-TCP) were extracted into this ionic liquid membrane, and back extracted into 10microL sodium hydroxide acceptor solution in the lumen of the hollow fiber. Then, the acceptor solution was withdrawn into the high-performance liquid chromatography (HPLC) microsyringe connected to the hollow fiber, and directly injected into the HPLC system for analysis. Some parameters that might affect the extraction efficiency were optimized, and low detection limits (0.5microgL(-1) for 4-CP, 3-CP, DCP and 1.0microgL(-1) for TCP) were obtained. Good repeatability was achieved because of the stability of the hollow fiber-supported ionic liquid membrane. The proposed procedure was applied for direct determination of the four chlorophenols in some real water samples including groundwater, river water, wastewater and tap water. All of the four chlorophenols in these water samples were under the limits of determination, and the recoveries were in the range of 70.0-95.7% at 5microgL(-1) spiked level.  相似文献   

11.
A modified headspace liquid-phase microextraction (HS-LPME) method was studied for the extraction of chlorophenols (CPs) from aqueous samples with complicated matrices, before gas chromatographic (GC) analysis with electron capture detection (ECD). Microwave heating was applied to accelerate the evaporation of CPs into the headspace, and an external-cooling system was used to control the sampling temperature. Conditions influencing extraction efficiency, such as the LPME-solvent, the sampling position of LPME, the sampling temperature, microwave power, and irradiation time (the same as sampling time), sample pH, and salt addition were thoroughly optimized. Experimental results indicated that the extraction of CPs from a 10mL aquatic sample (pH 1.0) was achieved with the best efficiency through the use of 1-octanol as solvent, microwave irradiation of 167W, and sampling at 45 degrees C for 10min. The detections were linear in the concentration of 5.0-100microg/L for 2,4-dichlorophenol (2,4-DCP), and 0.5-10microg/L for 2,4,6-trichlorophenol (2,4,6-TCP), 2,3,4,6-tetrachlorophenol (2,3,4,6-TeCP) and pentachlorophenol (PCP). Detection limits were found to be 0.7, 0.04, 0.07, and 0.08microg/L for 2,4-DCP, 2,4,6-TCP, 2,3,4,6-TeCP, and PCP, respectively. A landfill leachate sample was analyzed with recovery between 83 and 102%. The present method was proven to serve as a simple, sensitive, and rapid procedure for CP analysis in an aqueous sample.  相似文献   

12.
Chung LW  Lee MR 《Talanta》2008,76(1):154-160
Determination of trace chlorophenols (CPs) in environmental samples has been evaluated using liquid-phase microextraction (LPME) coupled with gas chromatography-mass spectrometry (GC-MS) without derivatization. The LPME procedure used to extract CPs from water involved 15 microL 1-octanol as acceptor solution in a 5.0 cm polypropylene hollow fiber with an inner diameter of 600 microm and a pore size of 0.2 microm. Under the optimal extraction conditions, enrichment factors from 117 to 220 are obtained. The obtained linear range is 1-100 ng mL(-1) with r(2)=0.9967 for 2,4-dichlorophenol (2,4-DCP); 1-100 ng mL(-1) with r(2)=0.9905 for 2,4,6-trichlorophenol (2,4,6-TCP); 5-500 ng mL(-1) with r(2)=0.9983 for 2,3,4,6-tetrachlorophenol (2,3,4,6-TeCP), and 10-1000 ng mL(-1) with r(2)=0.9929 for pentachlorophenol (PCP). The limits of detection range from 0.08 to 2 ng mL(-1), which is comparable with the reported values (12-120 ng mL(-1)). Recoveries of CPs in various matrices exceed 85% with relative standard deviations of less than 10%, except for PCP in landfill leachate. The applicability of this method was examined to determine CPs in environmental samples by analyzing landfill leachate, ground water and soil. The 2,4-DCP and 2,4,6-TCP detected in the landfill leachate are 6.68 and 2.47 ng mL(-1). The 2,4,6-TCP detected in ground water is 2.08 ng mL(-1). All the studied CPs are detected in contaminated soil. The proposed method is simple, low-cost, less organic solvent used and can potentially be applied to analyze CPs in complex environmental matrices.  相似文献   

13.
The aim of this work was to investigate the efficiency of various MWCNTs as SPE materials for the preconcentration of chlorophenols. The COOH-functionalized MWCNTs and MWCNTs were used as SPE sorbents. To evaluate the capability of MWCNTs for the preconcentration of chlorophenols from water samples, 2,4-chlorophenol, 4-chlorophenol, 2,4,6-chlorophenol, 2,6-chlorophenol, 3,4-chlorophenol, and 2-chlorophenol were used as model compounds. Chlorophenols were extracted with acetone, methanol, ethanol, and dichloromethane, and determined by gas chromatography–mass spectrometry. COOH-functionalized MWCNTs <8 nm were found to be the best sorbent for the tested chlorophenols. For COOH-functionalized MWCNTs <8 nm, the recovery rates for all chlorophenols were higher than 50% when acetone or ethanol was used as eluents. In the case of dichloromethane elution, recovery rates for chlorophenols were from 62.0% for 2,6-DCP to 116.8% for 2,4-DCP; only for 2,4,6-TCP was the recovery rate 30.6%. Similar percentage recoveries were achieved with methanol as the eluent.  相似文献   

14.
Two solid-phase extraction (SPE) methods, based on hydrophobic and selective (antibody-antigen) interactions, have been established and evaluated as clean-up methods prior the immunochemical analysis of 2,4,6-trichlorophenol (2,4,6-TCP) in urine samples. Without a clean-up method the extent of interferences caused by the urine matrix in the ELISA [R. Galve, M. Nichkova, F. Camps, F. Sanchez-Baeza, M.-P. Marco, Anal. Chem. 74 (2002) 468] varies depending on individual urine samples and accurate measurements are only possible when 2,4,6-TCP concentration levels are higher than 40 μg L−1. Both sample preparation methods improve detectability of the immunochemical method getting rid of the variability due to the intrinsic individual differences within the urine samples. Even though, the immunosorbent (IS)-SPE method developed has proven to be a superior sample preparation method eliminating completely matrix effects caused by both, non-hydrolyzed (NH) and hydrolyzed urine samples. The LOD reached by the C18-SPE-ELISA method (∼4 μg L−1 for free and total chlorophenols) is sufficient for exposure assessment of the occupationally exposed population. However, the detectability (0.66 and 0.83 μg L−1 in NH and hydrolyzed urine samples, respectively) accomplished by the IS-SPE-ELISA allows also biomonitoring potential exposure of non-occupationally exposed groups. Moreover, the specificity of the IS-SPE procedure can be modulated to provide a group-specific (9 chlorophenols and 2 bromophenols are extracted with an efficacy superior to 85%) or a more selective protocol (only 2,3,4,6-TtCP, 2,4,6-TCP are extracted with a recovery superior to 80% and 2,4,6-tribromophenol with a 70% recovery). On the other hand, the IS-SPE extracts produce cleaner chromatograms allowing quantitation by GC-ECD (or GC-MS) after toluene extraction and derivatization with a LOD near 0.1 μg L−1 in NH and hydrolyzed urine samples. The IS-SPE-ELISA method has been validated with GC-ECD using spiked and real urine samples. This study also provides evidences of the general exposure of the population to organochlorinated and organobrominated substances. Measurable levels of 2,4,6-TCP, 2,4,5-TCP, 2,3,4,6-TtCP, 2,4,6-TBP and 2,4-DBP have been detected in some of the samples used in this study.  相似文献   

15.
《Analytical letters》2012,45(2):262-272
Abstract

Hydrophobic deep eutectic solvents (DESs) were synthesized and developed for the preconcentration of three chlorophenols from wastewater by dispersive liquid–liquid microextraction (DLLME). The analyte concentrations were determined by high-performance liquid chromatography (HPLC). The hydrophobic DESs were prepared with the combination of hydrogen bond donors of decanoic acid or octanoic acid with different hydrogen bond acceptors of quaternary ammonium salts of tetrabutylammonium chloride, tetraoctylammonium chloride, methyltrioctylammonium chloride, and tetraheptylammonium chloride). Following the study of the stability and characterization by Fourier transform infrared spectroscopy, the hydrophobic DESs were developed as extractants and employed for the removal of 4-chlorophenol (4-CP), 2,4-dichlorophenol (2,4-DCP), and 2,4,6-trichlorophenol (2,4,6-TCP) from wastewater. Using hydrophobic DESs as the microextraction solvents, several key parameters were optimized, including the type and volume of the hydrophobic DES, pH, and time of the extraction procedure. Under the optimized conditions, good recoveries from 90.8% to 93.0% were obtained for the three chlorophenols. The limits of detection were less than 0.05?µg/mL with relative standard deviations between 1.8% and 3.1%. The method was applied for the isolation and determination of synthetic chlorophenols in wastewater.  相似文献   

16.
Liquid phase catalytic oxidation of chlorophenols (CPs) was carried out over Cu-Al hydrotalcite/clay composite at ambient temperature and pressure using hydrogen peroxide as oxidant. The results showed that the catalyst had high catalytic activity, with complete oxidation of 4-CP within 40 min at 40 °C. The content and position of chlorine on the aromatic ring had significantly different effects on the oxidation rate of CPs, with the rate sequence of phenol > monochlorophenol (MCP) > dichlorophenol (DCP) > trichlorophenol (TCP), 3-CP > 2-CP > 4-CP, and 3,5-DCP > 3,4-DCP > 2,5-DCP > 2,4-DCP > 2,6-DCP. This was ascribed to the interactions among σ-electron withdrawing conductive effect, π-electron donating conjugative effect, and steric hindrance effect of chlorine. It was evidenced that the catalytic peroxide oxidation of CPs in the first step was selective and rate-limiting, where chlorinated 1,4-benzoquinones formed.  相似文献   

17.
In this study we on-line coupled hollow fiber liquid–liquid–liquid microextraction (HF-LLLME), assisted by an ultrasonic probe, with high-performance liquid chromatography (HPLC). In this approach, the target analytes – 2-chlorophenol (2-CP), 3-chlorophenol (3-CP), 2,6-dichlorophenol (2,6-DCP), and 3,4-dichlorophenol (3,4-DCP) – were extracted into a hollow fiber (HF) supported liquid membrane (SLM) and then back-extracted into the acceptor solution in the lumen of the HF. Next, the acceptor solution was withdrawn on-line into the HPLC sample loop connected to the HF and then injected directly into the HPLC system for analysis. We found that the chlorophenols (CPs) could diffuse quickly through two sequential extraction interfaces – the donor phase – SLM and the SLM – acceptor phase – under the assistance of an ultrasonic probe. Ultrasonication provided effective mixing of the extracted boundary layers with the bulk of the sample and it increased the driving forces for mass transfer, thereby enhancing the extraction kinetics and leading to rapid enrichment of the target analytes. We studied the effects of various parameters on the extraction efficiency, viz. the nature of the SLM and acceptor phase, the compositions of the donor and acceptor phases, the fiber length, the stirring rate, the ion strength, the sample temperature, the sonication conditions, and the perfusion flow rate. This on-line extraction method exhibited linearity (r2 ≥ 0.998), sensitivity (limits of detection: 0.03–0.05 μg L−1), and precision (RSD% ≤ 4.8), allowing the sensitive, simple, and rapid determination of CPs in aqueous solutions and water samples with a sampling time of just 2 min.  相似文献   

18.
Two methods of determining the equilibrium constant of the reaction of the diphenyl-aminyl radical with 2,4,6-tri-tert-butylphenol were proposed; they are based on the high reactivity of aminyl radicals in cleavage of a H atom from phenol and phenoxyl radicals in cleavage of an H atom from an amine. In the first method (generation of aminyl radicals in a system containing phenol and amine), the forward reaction goes into quasiequilibrium, and the maximum concentration of phenoxyl radical formed and the concentrations of the other components calculated from the stoichiometry are used for calculating the equilibrium constant. In the second method (kinetic features of consumption of the phenoxyl radical in the presence of amine and phenol), the reverse reaction goes into quasiequilibrium, and the equilibrium constant is calculated in this case using the initial segments of the kinetic curve of consumption of phenoxyl. Both methods give similar values of the equilibrium constant.Translated from Izvestiya Akademii Nauk SSSR, Seriya Khimicheskaya, No. 8, pp. 1750–1755, August, 1989.We would like to thank E. T. Denisov for his valuable critical comments.  相似文献   

19.
R.M. Callejon  A.M. Troncoso  M.L. Morales   《Talanta》2007,71(5):1610-2097
A complete methodology for the determination of chloroanisoles and chlorophenols in cork material is proposed. The determination is accomplished by means of a previous liquid–solid extraction followed by stir bar sorptive extraction (SBSE) coupled to gas chromatography–mass spectrometry (GC–MS). Two different liquid–solid extraction experiments were conducted and eight compounds considered (2,6-dichloroanisole, 2,4-dichloroanisole, 2,4,6-trichloroanisole, 2,4,6-trichlorophenol, 2,3,4,6-tetrachloroanisole, 2,3,4,6-tetrachlorophenol, pentachloroanisole and pentachlorophenol). From the results obtained we can conclude that high volume extraction extending extraction time up to 24 h is the best choice if we have to release compounds from the inner surfaces of cork stoppers. Recovery percentages ranged from 51% for pentachloroanisole to 81% for 2,4-dichloroanisole. This method allows the determination of an array of compounds involved in cork taint at very low levels from 1.2 ng g−1 for 2,4,6-tricholoroanisole to 23.03 ng g−1 for 2,3,4,6-tetrachlorophenol.  相似文献   

20.
A porous and highly efficient polyaniline‐based solid‐phase microextraction (SPME) coating was successfully prepared by the electrochemical deposition method. A method based on headspace SPME followed by HPLC was established to rapidly determine trace chlorophenols in water samples. Influential parameters for the SPME, including extraction mode, extraction temperature and time, pH and ionic strength procedures, were investigated intensively. Under the optimized conditions, the proposed method was linear in the range of 0.5–200 μg/L for 4‐chlorophenol and 2,4,6‐trichlorophenol, 0.2–200 μg/L for 2,4‐dichlorophenol and 2–200 μg/L for 2,3,4,6‐tetrachlorophenol and pentachlorophenol, with satisfactory correlation coefficients (>0.99). RSDs were <15% (n = 5) and LODs were relatively low (0.10–0.50 μg/L). Compared to commercial 85 μm polyacrylate and 60 μm polydimethylsiloxane/divinylbenzene fibers, the homemade polyaniline fiber showed a higher extraction efficiency. The proposed method has been successfully applied to the determination of chlorophenols in water samples with satisfactory recoveries.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号