首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Ma HL  Tanner PA 《Talanta》2008,77(1):189-194
An isotope dilution method has been developed for the speciation analysis of chromium in natural waters which accounts for species interconversions without the requirement of a separation instrument connected to the mass spectrometer. The method involves (i) in-situ spiking of the sample with isotopically enriched chromium species; (ii) separation of chromium species by precipitation with iron hydroxide; (iii) careful measurement of isotope ratios using an inductively coupled plasma mass spectrometer (ICP-MS) with a dynamic reaction cell (DRC) to remove isobaric polyatomic interferences. The method detection limits are 0.4 μg L−1 for Cr(III) and 0.04 μg L−1 for Cr(VI). The method is demonstrated for the speciation of Cr(III) and Cr(VI) in local nullah and synthetically spiked water samples. The percentage of conversion from Cr(III) to Cr(VI) increased from 5.9% to 9.3% with increase of the concentration of Cr(VI) and Cr(III) from 1 to 100 μg L−1, while the reverse conversion from Cr(VI) to Cr(III) was observed within a range between 0.9% and 1.9%. The equilibrium constant for the conversion was found to be independent of the initial concentrations of Cr(III) and Cr(VI) and in the range of 1.0 (at pH 3) to 1.8 (at pH 10). The precision of the method is better than that of the DPC method for Cr(VI) analysis, with the added bonuses of freedom from interferences and simultaneous Cr(III) determination.  相似文献   

2.
We have developed a micro-electrothermal vaporization (μETV) device for the multiple collector-ICP-mass spectrometry (μETV-MC-ICPMS) to improve analytical precision in the 182W/183W and 184W/183W ratio measurements from nanogram quantities of W. The W solution was loaded onto the Re-filament, and the gradual evaporation of W was achieved by controlling the incident current onto the Re filament and D-Glucose. With the W evaporation under the Ar atmosphere, the measured W isotope ratios became erroneous mainly due to the contribution of signal spikes Ala-Arg-Gly-Phy-Tyr. In strike contrast, signal intensity profile became smooth when the He ambient/carrier gas was employed, and this resulted in better precision in the isotope ratio measurements. The measured UV–vis isotope ratio data obtained with present μETV technique were significantly deviated from the ratio data obtained with solution nebulization technique, mainly due to the contribution of the isotope fractionation effect through the evaporation process. Rigorous testing for the correction of the isotope fractionation processes pH–activity curve revealed that the Rayleigh fractionation law, rather than the conventional exponential law, provided the most reliable ratio data (1.851720 ± 0.000018 for 182W/183W and 2.141248 ± 0.000028 for 184W/183W ratios), which agreed well with the ratio data obtained through the conventional solution nebulization technique (1.851718 ± 0.000039 for 182W/183W and 2.141248 ± 0.000022 for 184W/183W). Moreover, mass dependency for the mass fractionation law suggested that W was evaporated as oxides (WO3), rather than the metallic form (W), from the Re filament, and therefore, information concerning the chemical form of the analytes could also be derived by the ETV technique developed in this study. The data presented here demonstrate clearly that the ETV sample introduction technique has a potential to become a sensitive tool for the precise isotope analysis for the MC-ICPMS technique.  相似文献   

3.
The paper describes the application of laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) for the isotopic analysis of individual uranium-oxide particles. The procedure developed is suitable for the accurate measurement of 234U, 235U, 236U and 238U isotopes in single actinide particles with lateral dimensions down to 10 μm. The 235U/238U isotope ratios can be obtained with a precision of a few percent relative standard deviation using a single collector ICP-MS instrument. The precision could be improved by the use of slow ablation and by taking several LA-ICP-MS replicate spectra on the same particle investigated. For the minor isotopes use of higher mass resolution (R = 4000) was necessary in some cases to avoid spectral interferences. The technique developed offers a rapid and accurate possibility for the isotopic composition determination of uranium-containing individual particles in environmental and safeguards samples.  相似文献   

4.
A new method for the determination of seawater Pb isotope compositions and concentrations was developed, which combines and optimizes previously published protocols for the separation and isotopic analysis of this element. For isotopic analysis, the procedure involves initial separation of Pb from 1 to 2 L of seawater by co-precipitation with Mg hydroxide and further purification by a two stage anion exchange procedure. The Pb isotope measurements are subsequently carried out by thermal ionization mass spectrometry using a 207Pb–204Pb double spike for correction of instrumental mass fractionation. These methods are associated with a total procedural Pb blank of 28 ± 21 pg (1sd) and typical Pb recoveries of 40–60%. The Pb concentrations are determined by isotope dilution (ID) on 50 mL of seawater, using a simplified version of above methods. Analyses of multiple aliquots of six seawater samples yield a reproducibility of about ±1 to ±10% (1sd) for Pb concentrations of between 7 and 50 pmol/kg, where precision was primarily limited by the uncertainty of the blank correction (12 ± 4 pg; 1sd). For the Pb isotope analyses, typical reproducibilities (±2sd) of 700–1500 ppm and 1000–2000 ppm were achieved for 207Pb/206Pb, 208Pb/206Pb and 206Pb/204Pb, 207Pb/204Pb, 208Pb/204Pb, respectively. These results are superior to literature data that were obtained using plasma source mass spectrometry and they are at least a factor of five more precise for ratios involving the minor 204Pb isotope. Both Pb concentration and isotope data, furthermore, show good agreement with published results for two seawater intercomparison samples of the GEOTRACES program. Finally, the new methods were applied to a seawater depth profile from the eastern South Atlantic. Both Pb contents and isotope compositions display a smooth evolution with depth, and no obvious outliers. Compared to previous Pb isotope data for seawater, the 206Pb/204Pb ratios are well correlated with 207Pb/206Pb, underlining the significant improvement achieved in the measurement of the minor 204Pb isotope.  相似文献   

5.
A fission track technique was used as a sample preparation method for subsequent isotope abundance ratio analysis of individual uranium containing particles with secondary ion mass spectrometry (SIMS) to measure the particles with higher enriched uranium efficiently. A polycarbonate film containing particles was irradiated with thermal neutrons and etched with 6 M NaOH solution. Each uranium containing particle was then identified by observing fission tracks created and a portion of the film having a uranium containing particle was cut out and put onto a glassy carbon planchet. The polycarbonate film, which gave the increases of background signals on the uranium mass region in SIMS analysis, was removed by plasma ashing with 200 W for 20 min. In the analysis of swipe samples having particles containing natural (NBL CRM 950a) or low enriched uranium (NBL CRM U100) with the fission track–SIMS method, uranium isotope abundance ratios were successfully determined. This method was then applied to the analysis of a real inspection swipe sample taken at a nuclear facility. As a consequence, the range of 235U/238U isotope abundance ratio between 0.0276 and 0.0438 was obtained, which was higher than that measured by SIMS without using a fission track technique (0.0225 and 0.0341). This indicates that the fission track–SIMS method is a powerful tool to identify the particle with higher enriched uranium in environmental samples efficiently.  相似文献   

6.
The determination of uranium isotope ratios in individual particles is of great importance for nuclear safeguards. In the present study, an analytical technique by inductively coupled plasma mass spectrometry (ICP-MS) with a desolvation sample introduction system was applied to isotope ratio analysis of individual uranium particles. In ICP-MS analysis of individual uranium particles with diameters ranging from 0.6 to 4.2 μm in a standard reference material (NBL CRM U050), the use of the desolvation system for sample introduction improved the precision of 234U/238U and 236U/238U isotope ratios. The performance of ICP-MS with desolvation was compared with that of a conventionally used method, i.e., secondary ion mass spectrometry (SIMS). The analysis of test swipe samples taken at nuclear facilities implied that the performance of ICP-MS with desolvation was superior to that of SIMS in a viewpoint of accuracy, because the problems of agglomeration of uranium particles and molecular ion interferences by other elements could be avoided. These results indicated that ICP-MS with desolvation has an enough ability to become an effective tool for nuclear safeguards.  相似文献   

7.
A mass spectrometric method to determine the absolute intramolecular (position-dependent) nitrogen isotope ratios of nitrous oxide (N2O) has been developed. It is based on the addition of different amounts of doubly labeled 15N2O to an N2O sample of the isotope ratio mass spectrometer reference gas, and subsequent measurement of the relative ion current ratios of species with mass 30, 31, 44, 45, and 46. All relevant quantities are measured by isotope ratio mass spectrometers, which means that the machines inherent high precision of the order of 10–5 can be fully exploited. External determination of dilution factors with generally lower precision is avoided. The method itself can be implemented within a day, but a calibration of the oxygen and average nitrogen isotope ratios relative to a primary isotopic reference material of known absolute isotopic composition has to be performed separately. The underlying theoretical framework is explored in depth. The effect of interferences due to 14N15N16O and 15N14N16O in the 15N2O sample and due to 15N 2 + formation are fully accounted for in the calculation of the final position-dependent nitrogen isotope ratios. Considering all known statistical uncertainties of measured quantities and absolute isotope ratios of primary isotopic reference materials, we achieve an overall uncertainty of 0.9 (1). Using tropospheric N2O as common reference point for intercomparison purposes, we find a substantially higher relative enrichment of 15N at the central nitrogen atom over 15N at the terminal nitrogen atom than measured previously for tropospheric N2O based on a chemical conversion method: 46.3±1.4 as opposed to 18.7±2.2. However, our method depends critically on the absolute isotope ratios of the primary isotopic reference materials air–N2 and VSMOW. If they are systematically wrong, our estimates will also necessarily be incorrect.  相似文献   

8.
A new method was proposed for the accurate determination of mercury in cosmetic samples based on isotopic dilution (ID)-photochemical vapor generation (PVG)-inductively coupled plasma mass spectrometry (ICP MS) measurement. Cosmetic samples were directly dissolved in formic acid solution and subsequently subjected to PVG for the reduction of mercury into vapor species following by ICP MS detection. Therefore, the risks of analyte contamination and loss were avoided. Highly enriched 201Hg isotopic spike is added to cosmetics and the isotope ratios of 201Hg/202Hg were measured for the quantitation of mercury. With ID calibration, the influences originating from sample matrixes for the determination of mercury in cosmetic samples have been efficiently eliminated. The effects of several experimental parameters, such as the concentration of the formic acid, and the flow rates of carrier gas and sample were investigated. The method provided good reproducibility and the detection limits were found to be 0.6 pg mL−1. Finally, the developed method was successfully applied for the determination of mercury in six cosmetic samples and a spike test was performed to verify the accuracy of the method.  相似文献   

9.
Tin isotopes were fractionated by the liquid-liquid extraction technique with a crown ether, dicyclohexano-18-crown-6. The isotopic ratios of mSn/120Sn (m: 116, 117, 118, 119, 122 and 124) were measured by multi-collector inductively coupled plasma spectrometry (MC-ICP-MS) on a Nu Plasma 500 with a precision better than 0.05 permil amu−1 on each isotopic ratio. Odd atomic mass isotopes (117Sn and 119Sn) showed depletions compared to the even atomic mass isotopes (116Sn, 118Sn, 122Sn and 124Sn). We show that this odd-even staggering property originates from the nuclear field shift effect. The contribution of the nuclear field shift effect to the observed isotope enrichment factor was estimated to be ∼35%.  相似文献   

10.
Iron isotope fractionation between liquid and vapor iron pentacarbonyl was measured in a closed system at ∼0 and ∼21 °C to determine if Fe isotope analysis of iron pentacarbonyl vapor is viable using electron-impact, gas-source mass spectrometry. At the 2σ level, there is no significant Fe isotope fractionation between vapor and liquid under conditions thought to reflect equilibrium. Experiments at ∼0 °C indicate iron pentacarbonyl vapor is ∼0.05 per mil (‰) greater in 56Fe/54Fe than liquid iron pentacarbonyl, which is just resolvable at the 1σ level. Partial decomposition of iron pentacarbonyl vapor or liquid to an iron oxide or iron metal shows that significant isotopic fractionation occurs, where the decomposed product has a lower 56Fe/54Fe ratio as compared to the starting iron pentacarbonyl. It follows that methods to decompose iron pentacarbonyl must be quantitative to obtain accurate isotope values.  相似文献   

11.
Isotope-labelling exchange experiments were carried out to investigate the kinetic stability of Cr(III) complexes with humic substances (HS). To compare the results with those of an ion, not expected to form kinetically stable HS complexes with respect to its electron configuration, Cu(II) was investigated under the same conditions. HS solutions of different origin were therefore spiked with 53Cr(III) or 65Cu(II) after saturation of HS with chromium and copper of natural isotopic composition. In fractions of metal/HS complexes with different molecular weight, obtained by ultrafiltration and HPLC/ICP-MS using size exclusion chromatography (SEC), respectively, the isotope ratios of chromium and copper were determined by ICP and thermal ionisation mass spectrometry. Distinct differences in the isotopic composition of chromium were found in the permeate of the ultrafiltration compared with the corresponding unseparated solution, which indicates kinetically stable Cr(III)/HS complexes. On the other hand, the copper isotopic composition was identical in the permeate and the unseparated solution, which shows that a total exchange of Cu2+ ions took place between free and HS complexed copper ions. The SEC/ ICP-MS experiments also resulted in a different isotopic distribution of chromium in the chromatographically separated complexes whereas the copper complexes, separated by SEC, showed identical isotopic composition. The kinetic stability of Cr(III)/HS complexes could be explained by the d3 electron configuration of Cr3+ ions, a fact which is well known from classical Cr(III) complexes, and influences substantially the mobility of this heavy metal in the environment.  相似文献   

12.
Isotope-labelling exchange experiments were carried out to investigate the kinetic stability of Cr(III) complexes with humic substances (HS). To compare the results with those of an ion, not expected to form kinetically stable HS complexes with respect to its electron configuration, Cu(II) was investigated under the same conditions. HS solutions of different origin were therefore spiked with 53Cr(III) or 65Cu(II) after saturation of HS with chromium and copper of natural isotopic composition. In fractions of metal/HS complexes with different molecular weight, obtained by ultrafiltration and HPLC/ICP-MS using size exclusion chromatography (SEC), respectively, the isotope ratios of chromium and copper were determined by ICP and thermal ionisation mass spectrometry. Distinct differences in the isotopic composition of chromium were found in the permeate of the ultrafiltration compared with the corresponding unseparated solution, which indicates kinetically stable Cr(III)/HS complexes. On the other hand, the copper isotopic composition was identical in the permeate and the unseparated solution, which shows that a total exchange of Cu2+ ions took place between free and HS complexed copper ions. The SEC/ ICP-MS experiments also resulted in a different isotopic distribution of chromium in the chromatographically separated complexes whereas the copper complexes, separated by SEC, showed identical isotopic composition. The kinetic stability of Cr(III)/HS complexes could be explained by the d3 electron configuration of Cr3+ ions, a fact which is well known from classical Cr(III) complexes, and influences substantially the mobility of this heavy metal in the environment. Received: 7 December 1998 / Revised: 25 March 1999 / Accepted: 27 March 1999  相似文献   

13.
Isotope dilution-thermal ionisation mass spectrometry (ID-TIMS) analysis has been applied to the determination of tin in a fly ash sample supplied by the EC Joint Research Centre (Ispra, Italy). The proposed procedure includes the silica gel/phosphoric acid technique for tin thermal ionisation activation and a strict heating protocol for isotope ratio measurements. Instrumental mass discrimination factor has been previously determined measuring a natural tin standard solution. Spike solution has been prepared from 112Sn-enriched metal and quantified by reverse isotope dilution analysis. Two sample aliquots were spiked and tin was extracted with 4.5 M HCl during 25 min ultrasound exposure time. Due to the complex matrix of this fly ash material, a two-step purification stage using ion-exchange chromatography was required prior TIMS analysis. Obtained results for the two sample-spike blends (10.11 ± 0.55 and 10.50 ± 0.64 μmol g−1) are comparable, both value and uncertainty. Also a good reproducibility is observed between measurements. The proposed ID-TIMS procedure, as a primary method and due to the lack of fly ash reference materials certified for tin content, can be used to validate more routine methodologies applied to tin determination in this kind of samples.  相似文献   

14.
This paper demonstrates the application of composite multi-walled carbon nanotube (MWNT) polyvinylchloride (MWNT-PVC) based on 1,5-diphenylcarbazide as chromium ionophore in potentiometric measurement. The sensor shows a good Nernstian slope of 19.52 ± 0.40 mV/decade in a wide linear range concentration of 6.3 × 10−8 to 1.0 × 10−2 M for Cr(NO3)3. The detection limit of this electrode was found to be 3.2 × 10−8 M of Cr(NO3)3 and is applicable in a pH range of 3.0-6.8. It has a short response time of about 10 s. This chromium electrode has a good selectivity over 16 various metal ions. The practical analytical utility of this electrode was demonstrated by measurement of Cr(III) in drinking water and mineral water samples without any serious preliminary pre-treatment and chromium in multivitamin.  相似文献   

15.
MeHg and inorganic Hg compounds were measured in aqueous media for isotope ratio analysis using aqueous phase derivatization, followed by purge-and-trap preconcentration. Compound-specific isotope ratio measurements were performed by gas chromatography interfaced to MC-ICP/MS. Several methods of calculating isotope ratios were evaluated for their precision and accuracy and compared with conventional continuous flow cold vapor measurements. An apparent fractionation of Hg isotopes was observed during the GC elution process for all isotope pairs, which necessitated integration of signals prior to the isotope ratio calculation. A newly developed average peak ratio method yielded the most accurate isotope ratio in relation to values obtained by a continuous flow technique and the best reproducibility. Compound-specific isotope ratios obtained after GC separation were statistically not different from ratios measured by continuous flow cold vapor measurements. Typical external uncertainties were 0.16‰ RSD (n = 8) for the 202Hg/198Hg ratio of MeHg and 0.18‰ RSD for the same ratio in inorganic Hg using the optimized operating conditions. Using a newly developed reference standard addition method, the isotopic composition of inorganic Hg and MeHg synthesized from this inorganic Hg was measured in the same run, obtaining a value of δ 202Hg = −1.49 ± 0.47 (2SD; n = 10). For optimum performance a minimum mass of 2 ng per Hg species should be introduced onto the column.  相似文献   

16.
Urinary creatinine (CRE) is an important biomarker of renal function. Fast and accurate quantification of CRE in human urine is required by clinical research. By using isotope dilution extractive electrospray ionization tandem mass spectrometry (EESI–MS/MS) a high throughput method for direct and accurate quantification of urinary CRE was developed in this study. Under optimized conditions, the method detection limit was lower than 50 μg L−1. Over the concentration range investigated (0.05–10 mg L−1), the calibration curve was obtained with satisfactory linearity (R2 = 0.9861), and the relative standard deviation (RSD) values for CRE and isotope-labeled CRE (CRE-d3) were 7.1–11.8% (n = 6) and 4.1–11.3% (n = 6), respectively. The isotope dilution EESI–MS/MS method was validated by analyzing six human urine samples, and the results were comparable with the conventional spectrophotometric method (based on the Jaffe reaction). Recoveries for individual urine samples were 85–111% and less than 0.3 min was taken for each measurement, indicating that the present isotope dilution EESI–MS/MS method is a promising strategy for the fast and accurate quantification of urinary CRE in clinical laboratories.  相似文献   

17.
Ulfbeck D  Baker J  Waight T  Krogstad E 《Talanta》2003,59(2):365-373
A new method for rapid sample digestion and efficient chemical separation of Hf and REE from rock samples for precise isotopic analysis is presented. Samples are digested by fusion in the presence of a lithium borate flux at 1100 °C and dissolved whilst molten in dilute nitric or hydrochloric acid. Prior to chemical separation using ion exchange techniques, Li and B from the flux material and Si from the sample are separated from the remaining major elements, REE and high field strength elements (HFSE) in the sample by Fe-hydroxide co-precipitation. The chemical separation of Hf is a two-stage procedure designed to first remove the remaining matrix elements (e.g. Fe, Ba) in the sample using standard cation exchange techniques, followed by separation of Hf from the REE and HFSE on TEVA extraction chromatographic resin. Hf yields are >90% and total procedural blanks are ca. 50 pg. Hf isotope ratios of a synthetic standard solution and replicate digestions of international rock standards BHVO-1 and BCR-1 measured on multi-collector inductively coupled plasma mass spectrometer (MC-ICPMS) reproduce similarly to ≤50 ppm (2 S.D.). The following elemental ratios are routinely obtained for elements, which interfere isobarically or may affect the ionisation and/or fractionation behaviour of Hf during analysis: 176Yb/176Hf<0.0001; 176Lu/176Hf<0.00001; Ti/Hf<0.05. This technique also provides a means of separating Nd from the REE fraction for isotopic analysis and, potentially, may be adapted for measurement of Lu/Hf ratios by isotope dilution techniques.  相似文献   

18.
Isotope dilution is a useful technique to measure the labile metal pool, which is the amount of metal in soil in rapid equilibrium (<7 days) with the soil solution. This is normally performed by equilibrating soil with a metal isotope, and sampling the labile metal pool by using an extraction (E value), or by growing plants (L value). For Cu, this procedure is problematic for E values, and impossible for L values, due to the short half-life of the 64Cu radioisotope (12.4 h), which makes access and handling very difficult. We therefore developed a technique using enriched 65Cu stable isotope and measurement of 63Cu/65Cu ratios by quadrupole inductively coupled plasma mass spectrometry (ICP-MS) to measure labile pools of Cu in soils using E value techniques. Mass spectral interferences in detection of 63Cu/65Cu ratios in soil extracts were found to be minimal. Isotope ratios determined by quadrupole ICP-MS compared well to those determined by high-resolution (magnetic sector) ICP-MS. E values determined using the stable isotope technique compared well to those determined using the radioisotope for both uncontaminated and Cu-contaminated soils.  相似文献   

19.
The precision of isotopic measurements of Pb by thermal ionization mass spectrometry (TIMS) is limited by the fact that this element does not possess an invariant isotope ratio that can be used for the correction of mass fractionation by internal normalization. Multiple-collector inductively coupled plasma mass spectrometry (MC-ICPMS) can overcome this limitation, because with plasma ionization, elements with overlapping mass ranges are thought to display identical mass discrimination. With respect to Pb, this can be exploited by the addition of Tl to the sample solutions; the mass discrimination factor obtained for Tl can then be used for the correction of the measured Pb isotope ratios. In this article we present the results of a detailed study that investigates the accuracy and precision of such an external correction technique for mass discrimination based upon the results of multiple analyses of a mixed standard solution of NIST SRM-981 Pb and SRM-997 Tl. Our data indicate that normalization of the Pb isotope ratios to the certified isotopic composition of SRM-997 Tl produces Pb isotopic results that are significantly lower than recently published reference values by TIMS. This systematic offset can be eliminated by renormalization of the Pb data to a different Tl isotopic composition to obtain an empirically determined mass discrimination factor for Pb that generates accurate results. It is furthermore shown that a linear law is least suited for the correction of mass discrimination, whereas a power or exponential law function provide significantly more accurate and precise results. In detail, it appears that a power law may provide the most appropriate correction procedure, because the corrected Pb isotope ratios display less residual correlations with mass discrimination compared to the exponentially corrected data. Using an exponential or power law correction our results, obtained over a period of over seven months, display a precision (2σ) of better than 60 parts per million (ppm) for 208Pb/206Pb and 207Pb/206Pb and of better than 350 ppm for 206Pb/204Pb, 207Pb/204Pb/204Pb, and 208Pb/204Pb. This represents a significant improvement compared to conventional TIMS techniques and demonstrates the potential of MC-ICPMS for routine, high-precision measurements of Pb isotopic compositions.  相似文献   

20.
A simple and sensitive multicommutated flow procedure, implemented by employing a homemade light emitting diode (LED) based photometer, has been developed for the determination of chromium (VI) and total chromium in water. The flow system comprised a set of four solenoid micro-pumps, which were assembled to work as fluid propelling and as commutating devices. The core of the detection unit comprised a green LED source, a photodiode and a homemade flow cell of 100 mm length and 2 mm inner diameter. The photometric procedure for the speciation of chromium in natural waters was based on the reaction of Cr (VI) with 1,5-diphenylcarbazide. Cr (III) was previously oxidized to Cr (VI) and determined as the difference between total Cr and Cr (VI). After carrying out the assays to select the best operational conditions the features of the method included: a linear response ranging from 10 to 200 μg l−1 Cr (III) and Cr (VI) (r = 0.999, n = 7); limits of detection of 2.05 and 1.0 μg l−1 for Cr (III) and Cr (VI), respectively; a relative standard deviation lower than 2.0% (n = 20) for a typical solution containing 50 μg l−1 Cr; a sampling throughput of 67 and 105 determinations per hour for total Cr and Cr (VI), respectively, and recovery values within the range of 93-108% for spiked concentrations of the order of 50 μg l−1.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号