首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Carbohydrates and proteins are among the most abundant naturally occurring biomolecules and so suitable methods for their reliable stable isotope analysis by gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS) are required. Due to the non-volatile nature of these compounds they require hydrolytic cleavage to their lower molecular weight subunits and derivatisation prior to GC/C/IRMS analysis. The addition of carbon to the molecules and any kinetic isotopic fractionation associated with derivatisation must be accounted for in order to provide meaningful stable isotope values and estimates of propagated errors. To illustrate these points amino acid trifluoroacetate/isopropyl esters and alditol acetates were prepared from authentic amino acids and monosaccharides, respectively. As predicted from the derivatisation reaction mechanisms, a kinetic isotope effect was observed which precludes direct calculation of delta(13)C values of the amino acids and monosaccharides by simple mass balance equations. This study shows that the kinetic isotope effect associated with derivatisation is both reproducible and robust, thereby allowing the use of correction factors. We show how correction factors can be determined and accurately account for the addition of derivative carbon. As a consequence of the addition of a molar excess of carbon and the existence of a kinetic isotope effect during derivatisation, errors associated with determined delta(13)C values must be assessed. We illustrate how such errors can be quantified (for monosaccharides +/-1.3 per thousand and for amino acids between +/-0.8 per thousand and +/-1.4 per thousand). With the magnitude of the errors for a given delta(13)C value of a monosaccharide or amino acid quantified, it is possible to make reliable interpretations of delta(13)C values, thereby validating the determination of delta(13)C values of amino acids as TFA/IP esters and monosaccharides as alditol acetates.  相似文献   

2.
A novel method for deducing the origins of heroin and the reagent used for acetylation was established based on delta(13)C determinations of heroin and its hydrolysate, morphine, using gas chromatography (13)C isotope ratio mass spectrometry (GC-C-IRMS). The alkaline and acid hydrolysis conditions of heroin were optimized. Both yield and purity of morphine produced could meet the requirement for a GC-C-IRMS analysis. Using (2-diethylaminoethyl-2,2- diphenylvalerate) as internal standard the determinations of heroin and morphine contents were performed with a GC method in a linear range of 0.2 to 2.0 mg ml(1) that was required to gain the isotope ratio results. The hydrolysis and synthesis of heroin did not change the delta(13)C value of morphine. The precision for delta(13)C detection of both heroin and morphine was sufficient for origin differentiation of heroin samples. The information about the origins of acetylation reagents could be deduced from the difference of delta(13)C values between heroin and morphine. The results for origin differentiation of 10 heroin samples grouped into different regions and their acetylating agents were satisfactory.  相似文献   

3.
In this paper we present an automated system for simultaneous measurement of CO(2) concentration, delta(13)C and delta(18)O from small (<1 mL) air samples in a short period of time (approximately 1 hour). This system combines continuous-flow isotope ratio mass spectrometry (CF-IRMS) and gas chromatography (GC) with an inlet system similar to conventional dual-inlet methods permitting several measurement cycles of standard and sample air. Analogous to the dual-inlet method, the precision of this system increases with the number of replicate cycles measured. The standard error of the mean for a measurement with this system is 0.7 ppm for the CO(2) concentration and 0.05 per thousand for the delta(13)C and delta(18)O with four replicate cycles and 0.4 ppm and 0.03 per thousand respectively with nine replicate cycles. The mean offset of our measurements from NOAA/CMDL analyzed air samples was 0.08 ppm for the CO(2) concentration, 0.01 per thousand for delta(13)C and 0.00 per thousand for delta(18)O. A specific list of the parts and operation of the system is detailed as well as some of the applications for micrometeorological and ecophysiological applications.  相似文献   

4.
5.
A simple and rapid method to measure naturally occurring delta(13)C values of headspace CO(2) of sparkling drinks has been set up, using direct injections on a gas chromatograph coupled to an isotope ratio mass spectrometer, through a combustion interface (GC/C/IRMS). We tested the method on CO(2) gas from several origins. No significant isotopic fractionation was observed nor influences by secondary compounds eventually present in the gas phase. Standard deviation for these measurements was found to be <0.1 per thousand.  相似文献   

6.
A gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS) method is described and validated for measurement of delta(13)C values of the acetate derivatives of urinary etiocholanolone and androsterone. The analysis was performed with only 2 mL of urine. The sample preparation consisted of deconjugation with beta-glucuronidase, solid phase extraction, and derivatization with acetic anhydride and pyridine. The within-assay precision of two quality control (QC) urine samples ranged from 0.5 to 2.1 CV%. The between-assay precision in the same QC urines ranged from 1.7 to 3.4 CV%. Administration of testosterone enanthate to a subject resulted in a 6 per thousand decrease in delta(13)C values from -25 per thousand (baseline) to -31 per thousand. Two weeks after testosterone administration was discontinued, the delta(13)C values remained abnormally low while the urine testosterone/epitestosterone (T/E) ratio returned to less than 6. This relatively simple method is useful for rapidly screening a large number of urine samples, including those with T/E <6.  相似文献   

7.
A reference method to accurately define kinetics in response to the ingestion of glucose in terms of total, exogenous and endogenous glucose is to use stable‐isotope‐labelled compounds such as 2H and 13C glucose followed by gas chromatography/mass spectrometry (GC/MS) and gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS) analysis. The use of the usual pentaacetyl (5Ac) derivative generates difficulties in obtaining accurate and reproducible results due to the two chromatographic peaks for the syn and anti isomers, and to the isotopic effect occurring during acetylation. Therefore, the pentaacetylaldononitrile derivative (Aldo) was validated for both isotopes, and compared with the 5Ac derivative. A correction factor including carbon atom dilution (stoichiometric equation) and the kinetic isotopic effect (KIE) was determined. Analytical validation results for the 2H GC/MS and 13C GC/C/IRMS measurements produced acceptable results with both derivatives. When 2H enrichments of plasma samples were ≤1 mol % excess (MPE), the repeatability (RSDAldo Intra assay and Intra day <0.94%, RSD5Ac Intra assay and Intra day <3.29%), accuracy (Aldo <3.4%, 5Ac <29.0%), and stability of the derivatized samples were significantly better when the Aldo derivatives of the plasma samples were used (p < 0.05). When the glucose kinetics were assessed in nine human subjects, after glucose ingestion, the plasma glucose 2H enrichments were identical with both derivatives, whereas the 13C enrichments needed a correction factor to fit together. Due to KIE variation, this correction factor was not constant and had to be calculated for each batch of analyses, to obtain satisfactory results. Mean quantities of exogenous glucose exhibit marked difference (20.9 ± 1.3g (5Ac) vs. 26.7 ± 2.5g (Aldo)) when calculated with stoichiometric correction, but fit perfectly when calculated after application of the correction factor (22.1 ± 1.3g (5Ac) vs. 22.9 ± 1.9g (Aldo)). Finally, the pentaacetylaldononitrile derivative, used here in GC/C/IRMS for the first time, enables measurement of 2H and 13C enrichments in plasma glucose with a single sample preparation. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

8.
A simple method for the determination of nanomole amounts of (13)CO(2) generated from an in vitro reaction is reported. The incubation medium contains a known amount of unlabeled sodium bicarbonate and the gaseous (13)CO(2) enriches the atmosphere upon which a measurement of the isotopic enrichment ((13)CO(2)/(12)CO(2)) is made corresponding to a reverse isotope dilution. The quantification of the (13)CO(2) was performed by gas chromatography/isotope ratio mass spectrometry. This assay was validated in terms of linearity, accuracy and precision using three different substrates which produce (13)CO(2) either by enzymatic reaction [(13)C]urea, sodium [(13)C]formate) or by chemical reaction (sodium [(13)C]bicarbonate). Four calibration curves were tested for each (13)C-labeled substrate, allowing the quantification of (13)CO(2) from 25 pmol to 150 nmol. The dynamics of the assay were obtained as a function of the quantity of unlabeled sodium bicarbonate added to each sample.  相似文献   

9.
Gas isotope ratio mass spectrometers usually measure ion current ratios of molecules, not atoms. Often several isotopologues contribute to an ion current at a particular mass‐to‐charge ratio (m/z). Therefore, corrections have to be applied to derive the desired isotope ratios. These corrections are usually formulated in terms of isotope ratios (R), but this does not reflect the practice of measuring the ion current ratios of the sample relative to those of a reference material. Correspondingly, the relative ion current ratio differences (expressed as δ values) are first converted into isotopologue ratios, then into isotope ratios and finally back into elemental δ values. Here, we present a reformulation of this data reduction procedure entirely in terms of δ values and the ‘absolute’ isotope ratios of the reference material. This also shows that not the absolute isotope ratios of the reference material themselves, but only product and ratio combinations of them, are required for the data reduction. These combinations can be and, for carbon and oxygen have been, measured by conventional isotope ratio mass spectrometers. The frequently implied use of absolute isotope ratios measured by specially calibrated instruments is actually unnecessary. Following related work on CO2, we here derive data reduction equations for the species O2, CO, N2O and SO2. We also suggest experiments to measure the required absolute ratio combinations for N2O, SO2 and O2. As a prelude, we summarise historic and recent measurements of absolute isotope ratios in international isotope reference materials. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

10.
There is a growing interest in the use of (13)C-enriched substrates to investigate metabolic processes in humans. The non-invasive nature of (13)C breath tests makes them attractive to clinicians, particularly because they can be safely used in children. The availability of suitable (13)C-enriched substrates can limit the application of this biotechnology. We have used isotope ratio mass spectrometry to assay the chemical purity and isotopic enrichment of substrates that were synthesised to study gut transit and colonic fermentation. Lactose ureide and lactose [(13)C]ureide were synthesised by acid-catalysed condensation of lactose and urea or (13)C urea, respectively. Glucose ureide and glucose [(13)C]ureide were synthesised by similar methods but required an additional purification step to remove urea of crystallisation. Substrates were analysed by standard analytical techniques and combustion isotope ratio mass spectrometry for carbon and nitrogen content and (13)C-enrichment. Monitoring the C/N ratio proved to be a sensitive assay of chemical purity. Analysis of the percentage composition of C and N (and hence O + H) suggested that lactose ureide crystallises as the dihydrate. It was synthesised with approximately 99% chemical purity and with the theoretical enrichment. Glucose ureide was synthesised with approximately 98% chemical purity but with lower than theoretical enrichment.  相似文献   

11.
Gas chromatography/combustion/mass spectrometry (GC-C-MS) and elemental analysis/mass spectrometry (EA-MS) techniques are proposed to estimate delta(13)C and delta(15)N values in heroin, morphine, cocaine and hemp leaves, for the purposes of tracing the geographical origins of seized drugs. The values of isotope ratios for pure drugs and drugs with impurities were compared. It was demonstrated that large samples (up to 3 x 10(-6) g C) were combusted completely, so that the results obtained were valid. The data are considered to be an essential supplement to a wide-scale database designed specifically for the delta(13)C and delta(15)N values of drugs. The potential forensic and academic significance of the results is discussed.  相似文献   

12.
Compound-specific deltaD and delta13C analyses of gas mixtures are useful indicators of geochemical and environmental factors. However, the relative concentrations of individual components in gas mixtures (e.g., H2, CO2, methane, ethane, propane, i-butane, n-butane) may vary over several orders of magnitude. The determination of hydrogen and carbon compound-specific stable isotope ratios requires that the hydrogen and carbon dioxide produced from each separated component has a concentration adjusted to match the dynamic range of the stable isotope mass spectrometer. We present a custom-built gas sampling and injection system (GASIS) linked with a Delta Plus XP mass spectrometer that provides flexibility, ease of operation, and economical use of small gas samples with wide ranges of analyte concentrations. The overall on-line GC-ox/red-IRMS (Gas Chromatography - oxidation/reduction - Isotope Ratio Mass Spectrometry) system consists of (i) a customized GASIS inlet system and (ii) two alternative reactors, namely an oxidative Cu-Ni-Pt reactor at 950 degrees C for production of CO2 and a reductive graphitized Al2O3 reactor at 1420 degrees C for production of H2. In addition, the system is equipped with (iii) a liquid nitrogen spray-cooling unit for cryo-GC-focusing at -20 degrees C, and (iv) a Nafion dryer for removal of water vapor from product CO2. The three injection loops of the GASIS inlet allow flexibility in the volume of injected analyte gas (e.g., from 0.06 to 500 microL) in order to measure reproducible deltaD and delta13C values for gases at concentrations ranging from 100% down to 10 ppm. We calibrate our GC-ox/red-IRMS system with two isotopically distinct methane references gases that are combusted off-line and characterized using dual-inlet IRMS.  相似文献   

13.
Compound-specific stable carbon isotope analysis of amino acids by gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS) is a highly selective and sensitive method for probing the biosynthetic/diagenetic pathways, pool size and turnover rates of proteins, previously intractable to bulk isotope analyses. However, amino acids are polyfunctional, non-volatile compounds which require derivatisation prior to GC analysis. While a wide range of derivatives exist for the GC analysis of amino acids only a handful have been utilised for their GC/C/IRMS analysis. Significantly, none of those derivatives currently employed appear completely satisfactory and a thorough assessment of their relative utility is lacking. Seven derivatives (three previously reported and four novel) for obtaining delta(13)C values of amino acids via GC/C/IRMS analysis were compared. More specifically, standard mixtures of 15 protein amino acids were converted into N-acetylmethyl (NACME) esters, N-acetyl n-propyl (NANP) esters, N-acetyl i-propyl (NAIP) esters, N-trifluoroacetyl-i-propyl (TFA-IP) esters, N-pivaloyl methyl (NPME) esters, N-pivaloyl n-propyl (NPNP) esters and N-pivaloyl i-propyl (NPIP) esters. Each derivative was assessed with respect to its applicability to carbon isotope determinations of all the common alpha-amino acids, reaction yield, chromatographic resolution, stability, analyte-to-derivative carbon ratio, kinetic isotope effects and errors associated with their carbon isotope determinations. The NACME derivative was concluded to be the preferred derivative mainly due to the highest analyte-to-derivative carbon ratio being achieved, resulting in the lowest analytical errors for amino acid delta(13)C value determinations, ranging from +/-0.6 per thousand for phenylalanine, leucine and isoleucine to +/-1.1 per thousand for serine and glycine.  相似文献   

14.
15.
Past atmospheric composition can be reconstructed by the analysis of air enclosures in polar ice cores which archive ancient air in decadal to centennial resolution. Due to the different carbon isotopic signatures of different methane sources high-precision measurements of delta13CH4 in ice cores provide clues about the global methane cycle in the past. We developed a highly automated (continuous-flow) gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS) technique for ice core samples of approximately 200 g. The methane is melt-extracted using a purge-and-trap method, then separated from the main air constituents, combusted and measured as CO2 by a conventional isotope ratio mass spectrometer. One CO2 working standard, one CH4 and two air reference gases are used to identify potential sources of isotope fractionation within the entire sample preparation process and to enhance the stability, reproducibility and accuracy of the measurement. After correction for gravitational fractionation, pre-industrial air samples from Greenland ice (1831 +/- 40 years) show a delta13C(VPDB) of -49.54 +/- 0.13 per thousand and Antarctic samples (1530 +/- 25 years) show a delta13C(VPDB) of -48.00 +/- 0.12 per thousand in good agreement with published data.  相似文献   

16.
This study was directed towards investigating suitable compounds to be used as stable isotope reference materials for gas chromatography combustion isotope ratio mass spectrometry (GC-C-IRMS) calibration. Several compounds were selected from those used in the 'Grob-test' mixture. Oxygen- and nitrogen-containing substances were added to these compounds to allow the mixture to be used as a possible multi-isotopic calibration tool for 2H/1H, 13C/12C, 15N/14N and 18O/16O ratio determinations. In this paper we present the results of delta13C measurements performed by the consortium of the five laboratories taking part in this inter-calibration exercise. All the compounds were individually assessed for homogeneity, short-term stability and long-term stability by means of EA-IRMS, as required by the bureau communitaire de reference (BCR) Guide for Production of Certified Reference Materials. The results were compared then with the GC-C-IRMS measurements using both polar and non-polar columns, and the final mixture of selected compounds underwent a further certification exercise assessing limits of accuracy and reproducibility under specified GC-C-IRMS conditions.  相似文献   

17.
The effect of the feeding on the 13C/12C isotope ratio of four endogenous steroid hormones testosterone (T), epi-testosterone (epi-T), dehydroepiandrosterone (DHEA) and etiocholanolone (ETIO) in bovine urine was investigated. An analytical method to determine the accurate isotope ratio was developed including an extensive clean up followed by enrichment of the analytes in two steps of HPLC fractionation. Feeding experiments with four young animals were performed using C3 and C4 plants (grass, maize silage, hay, etc.) over a time period of about 280 days. One cattle was used as a control animal with no change of its diet over the full period. The detection of the 13C/12C isotope ratio of the acetylated extracts was performed by gas chromatography/combustion isotope ratio mass spectrometry. After the first change of the feeding from C4 to C3 plants significant changes of the delta 13C % values were observed from the -19 to -23% level to the -24 to -32% level for etiocholanolone and epi-testosterone in urine of three animals, whereas the DHEA values remained under the level of the two metabolites. Testosterone could not be detected with GC-C-IRMS due to its low concentration in young animals. After the second change of the diet from C3 to C4 plants (after 222 days), the measured delta 13C % values have been stabilised at the original level. The results show that in case of the feeding with only C3 plants the endogenous delta values of -32% can be reached. In this case the contribution of exogenous material with a delta value of -32% could not be detected independently of the concentration. If the diet contains C4 plants the difference or the ratio of the delta 13C % values becomes the determinant in the discriminatory power. For validation of the method a human and a cattle were treated with testosterone and the delta 13C % values were measured in incurred human and cattle urine.  相似文献   

18.
19.
A new procedure for the determination of carbon dioxide (CO(2)) (13)C/(12)C isotope ratios, using direct injection into a GasBench/isotope ratio mass spectrometry (GasBench/IRMS) system, has been developed to improve isotopic methods devoted to the study of the authenticity of sparkling drinks. Thirty-nine commercial sparkling drink samples from various origins were analyzed. Values of delta(13)C(cava) ranged from -20.30 per thousand to -23.63 per thousand, when C3 sugar addition was performed for a second alcoholic fermentation. Values of delta(13)C(water) ranged from -5.59 per thousand to -6.87 per thousand in the case of naturally carbonated water or water fortified with gas from the spring, and delta(13)C(water) ranged from -29.36 per thousand to -42.09 per thousand when industrial CO(2) was added. It has been demonstrated that the addition of C4 sugar to semi-sparkling wine (aguja) and industrial CO(2) addition to sparkling wine (cava) or water can be detected. The new procedure has advantages over existing methods in terms of analysis time and sample treatment. In addition, it is the first isotopic method developed that allows (13)C/(12)C determination directly from a liquid sample without previous CO(2) extraction. No significant isotopic fractionation was observed nor any influence by secondary compounds present in the liquid phase.  相似文献   

20.
A common elemental analyzer system connected to a temperature-controlled gas chromatography (GC) column and coupled to an isotope ratio mass spectrometer was improved to decrease the determination limit for a simultaneous stable isotope ratio measurement of nitrogen and carbon dioxide. The additional use of a special ashtray system to collect the combustion residuals permitted more time-efficient work. These modifications to the elemental analyzer allowed precise measurements to be made down to 1.5 microg nitrogen and 10 microg carbon for stable isotope analysis. Low system background values and an acceptable signal-to-noise ratio have made an additional blank correction for these low sample measurements unnecessary. We provide a precision of this stable isotope analysis for lowest amounts of 1.2-2 microg nitrogen with a standard deviation of +/-0.496 per thousand (n = 27) and for 8.2-15 microg carbon with a standard deviation of +/-0.257 per thousand (n = 31) across different sample runs under stipulated conditions. This application can be established in an automatic mode without cryofocusing procedures.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号