首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A method for the simultaneous extraction of four tricyclic antidepressants from human plasma samples using pipette tip SPE with MonoTip C(18) tips is presented. Human plasma (0.1 mL) containing four tricyclic antidepressants (amitriptyline, amoxapine, imipramine, and trimipramine) and an internal standard (IS), protriptyline, was mixed with 0.4 mL of distilled water and 100 microL 1 M NaOH solution. After centrifugation of the mixture, the supernatant was extracted to the C(18) phase of the tip by 20 repeated aspirating/dispensing cycles using a manual micropipettor. The analytes retained in the tip were eluted with methanol by five repeated aspirating/dispensing cycles. Without evaporation and reconstitution, the eluate was directly injected into a gas chromatograph injector and detected by a mass spectrometer with SIM in the positive-ion electron impact mode. Recovery of the four antidepressants and IS spiked into human plasma was 80.2-92.1%. The regression equations for the four antidepressants showed excellent linearity in the range of 0.2-40 ng/0.1 mL. LODs and LOQs for the four drugs were 0.05-0.2 ng/0.1 mL and 0.2-0.5 ng/0.1 mL, respectively. Intra- and interday CVs for the four drugs in plasma were no greater than 9.5%.  相似文献   

2.
A highly sensitive liquid chromatography-tandem mass spectrometry method for the simultaneous quantification of midazolam and its major metabolites 1'-hydroxymidazolam and 4-hydroxymidazolam in human plasma was developed and validated. Stable isotope-labeled midazolam-D(4) and 1'-hydroxymidazolam-D(4) were used as internal standards. Compounds were extracted from 0.5 mL plasma by liquid-liquid extraction with ethyl acetate-heptane (1:4). Chromatography was achieved using a Sunfire C(18) column. The mobile phase was a gradient with 10 m m formic acid in Milli-Q water and methanol at a flow rate of 0.3 mL/min. Total run time was 10 min. Detection was performed using a tandem mass spectrometer with positive electrospray ionization. Calibration curves were linear over the range of 0.10-50.0 ng/mL for midazolam and 0.025-25.0 ng/mL for both metabolites. For all compounds the lower limit of quantification was 0.10 ng/mL. Imprecision was assessed according to the NCCLS EP5-T guideline and was below 10% for all compounds. Mean recoveries were between 94 and 109% for midazolam and its metabolites. The validated method was successfully applied in a pharmacokinetic study investigating in vivo CYP3A-activity in a large cohort of renal allograft recipients using sub-therapeutic doses of midazolam as a drug-probe.  相似文献   

3.
A sensitive, accurate and reliable bioanalytical method for the enantioselective determination of metoprolol in plasma and saliva samples utilizing liquid chromatography–electrospray ionization tandem mass spectrometry was developed and validated. Human plasma and saliva samples were pretreated by microextraction by packed sorbent (MEPS) prior to analysis. A new MEPS syringe form with two inputs was used. Metoprolol enantiomers and internal standard pentycaine (IS) were eluted from MEPS sorbent using isopropanol after removal of matrix interferences using aliquots of 5% methanol in water. Complete separation of metoprolol enantiomers was achieved on a Cellulose‐SB column (150 × 4.6 mm, 5 μm) using isocratic elution with mobile phase 0.1% ammonium hydroxide in hexane–isopropanol (80:20, v/v) with a flow rate of 0.8 mL/min. A post‐column solvent‐assisted ionization was applied to enhance metoprolol ionization signal in positive mode monitoring (+ES) using 0.5% formic acid in isopropanol at a flow rate of 0.2 mL/min. The total chromatographic run time was 10 min for each injection. The detection of metoprolol in plasma and saliva samples was performed using triple quadrupole tandem mass spectrometer in +ES under the following mass transitions: m/z 268.08 → 72.09 for metoprolol and m/z 303.3 → 154.3 for IS. The linearity range was 2.5–500 ng/mL for both R‐ and S‐metoprolol in plasma and saliva. The limits of detection and quantitation for both enantiomers were 0.5 and 2.5 ng/mL respectively, in both matrices (plasma and saliva). The intra‐ and inter‐day precisions were presented in terms of RSD values for replicate analysis of quality control samples and were <5%; the accuracy of determinations varied from 96 to 99%. The method was able to determine the therapeutic levels of metoprolol enantiomers in both human plasma and saliva samples successfully, which can aid in therapeutic drug monitoring in clinical laboratories. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

4.
A new method is described for the qualitative and quantitative analysis of midazolam, a short-acting 1,4-imidazole benzodiazepine, in human plasma. It involves a plasma deproteinization step, solid-phase microextraction (SPME) of midazolam using an 85-microm polyacrylate fiber, and its detection by gas chromatography/mass spectrometry (GC/MS) in selected ion monitoring (SIM) mode, using pinazepam as internal standard. The assay is linear over a midazolam plasma range of 1.5-300 ng/mL, relative intra- and inter-assay standard deviations at 5 ng/mL are below 7%, and the limit of detection is 1 ng/mL. The method is simple, fast and sufficiently sensitive to be applied in clinical and forensic toxicology as well as for purposes of therapeutic drug monitoring.  相似文献   

5.
An isocratic reversed-phase high-performance liquid chromatography method with UV detection is developed and validated for the simultaneous determination of ketamine, xylazine, and midazolam in canine plasma. Analytes are extracted from alkalinized samples into diethyl ether-methylene chloride (7:3, v:v) using single-step liquid-liquid extraction. Chromatographic separation is performed on a C(18) column using a mobile phase containing an acetonitrile-methanol-10 mM sodium heptanesulfonate buffer adjusted to pH 3, with glacial acetic acid (44:10:46, v:v) at a detection wavelength of 210 nm, with a total runtime of 10 min. The calibration is linear over the range of 78.125-5000 ng/mL for ketamine and 15.625-1000 ng/mL for xylazine and midazolam. The limits of detection are 17.8, 10.3, and 15.1 ng/mL for ketamine, xylazine, and midazolam, respectively. The extraction recoveries are 76.1% for ketamine, 91.0% for midazolam, and 78.2% for xylazine. The method is successfully used for clinical and pharmacokinetic studies of the three-drug fixed dose combination formulations.  相似文献   

6.
A rapid and sensitive method for the analysis of delta9-tetrahydrocannabinol (THC) in preserved oral fluid was developed and fully validated. Oral fluid was collected with the Intercept, a Food and Drug Administration (FDA) approved sampling device that is used on a large scale in the U.S. for workplace drug testing. The method comprised a simple liquid-liquid extraction with hexane, followed by liquid chromatography-tandem mass spectrometry (LC-MS-MS) analysis. Chromatographic separation was achieved using a XTerra MS C18 column, eluted isocratically with 1 mM ammonium formate-methanol (10:90, v/v). Selectivity of the method was achieved by a combination of retention time, and two precursor-product ion transitions. The use of the liquid-liquid extraction was demonstrated to be highly effective and led to significant decreases in the interferences present in the matrix. Validation of the method was performed using both 100 and 500 MicroL of oral fluid. The method was linear over the range investigated (0.5-100 ng/mL and 0. 1-10 ng/mL when 100 and 500 microL, respectively, of oral fluid were used) with an excellent intra-assay and inter-assay precision (relative standard deviations, RSD <6%) for quality control samples spiked at a concentration of 2.5 and 25 ng/mL and 0.5 and 2.5 ng/mL, respectively. Limits of quantification were 0.5 and 0.1 ng/mL when using 100 and 500 microL, respectively. In contrast to existing GC-MS methods, no extensive sample clean-up and time-consuming derivatisation steps were needed. The method was subsequently applied to Intercept samples collected at the roadside and collected during a controlled study with cannabis.  相似文献   

7.
A simple, sensitive and rapid liquid chromatography/electrospray ionization mass spectrometry (LC/ESI-MS) method was developed and validated for the quantification of valproic acid, an antiepileptic drug, in human plasma using benzoic acid as internal standard (IS). Following solid-phase extraction, the analytes were separated using an isocratic mobile phase on a reversed-phase C18 column and analyzed by MS in the single ion monitoring mode using the respective [M-H]- ions, m/z 143 for valproic acid and m/z 121 for the IS. The assay exhibited a linear dynamic range of 0.5-60 microg/mL for valproic acid in human plasma. The lower limit of quantification was 500 ng/mL with a relative standard deviation of less than 10%. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. The average absolute recoveries of valproic acid and the IS from spiked plasma samples were 96.1+/-4.2 and 95.6+/-2.7%, respectively. A run time of 4.5 min for each sample made it possible to analyze more than 250 human plasma samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability and bioequivalence studies.  相似文献   

8.
A confirmatory method has been developed and validated for the determination of chlormadinone acetate (CMA), megestrol acetate (MGA), melengestrol acetate (MLA) and medroxyprogesterone acetate (MPA) in bovine and porcine plasma. Analytes are extracted from plasma samples using matrix-assisted liquid-liquid extraction (LLE) on Extrelut NT columns followed by C18 solid-phase extraction (SPE). Analytes were analysed using liquid chromatography-tandem mass spectrometry (LC-MS/MS), and quantification was performed using matrix-matched calibration standards in combination with deuterated internal standards. In accordance with Commission Decision 2002/657/EC, two ion transitions were monitored for each analyte. Decision limits (CCalpha) were estimated by analysing 20 blank plasma samples and ranged from 0.1 to 0.2 ng mL(-1). Detection capabilities (CCbeta) were estimated using 20 plasma samples fortified at 0.5 ng mL(-1) and were <0.5 ng mL(-1). In the range 0.5-2 ng mL(-1), the mean intra-laboratory reproducibility of the analytes ranged from 6 to 18% (%R.S.D.). Analytes were shown to be stable in fortified plasma samples for >8 months when stored at -20 degrees C.  相似文献   

9.
A liquid chromatography/mass spectrometry method, for rapid determination of five cytochrome P450 (CYP) probe drugs and their relevant metabolites in human plasma and urine, is described. The five specific probe substrates/metabolites, caffeine/paraxanthine (CYP1A2), tolbutamide/4-hydroxytolbutamide/carboxytolbutamide (CYP2C9), omeprazole/5-hydroxyomeprazole (CYP2C19), debrisoquine/5-hydroxydebrisoquine (CYP2D6) and midazolam/1'-hydroxymidazolam (CYP3A), together with the internal standards (phenacetin and paracetamol), in plasma and urine, were extracted using solid-phase extraction. The chromatography was performed using a C18 column with an isocratic mobile phase consisting of acetonitrile and 0.1% formic acid in water (70:30). The triple-quadrupole mass spectrometer was operated in both positive and negative modes, and multiple reaction monitoring was used for quantification. The method was validated over the concentration ranges 0.05-5 microg/mL for caffeine and paraxanthine, 0.02-2 microg/mL for tolbutamide, 0.1-20 microg/mL for 4-hydroxytolbutamide, carboxytolbutamide, debrisoquine and 5-hydroxydebrisoquine, 5-2500 ng/mL for omeprazole and 5-hydroxyomeprazole, and 1-100 ng/mL for midazolam and 1'-hydroxymidazolam. The intra- and inter-day precision were 0.3-13.7% and 1.9-14.3%, respectively, and the accuracy ranged from 93.5-107.2%. The lower limit of quantification varied between 1 and 100 ng/mL. The present method provides a robust, fast and sensitive analytical tool for the five-probe drug cocktail, and has been successfully applied to a clinical phenotyping study in 16 subjects.  相似文献   

10.
制备了一种新型的聚苯乙烯纳米纤维, 将其作为固相萃取吸附剂装填制成固相萃取柱, 与高效液相色谱联用建立了干辣椒、 水果饮料及红酒中罗丹明B的定量分析方法. 高效液相色谱以3 g/L磷酸缓冲液-甲醇混合溶液(体积比3∶7, pH=7.0)为流动相. 通过对提取条件的优化, 得到该方法对干辣椒中罗丹明B的检出限为0.1 ng/g, 最低定量限为0.6 ng/g; 对水果饮料和红酒中罗丹明B的检出限均为0.2 ng/mL, 最低定量限均为0.5 ng/mL. 此方法对干辣椒中罗丹明B的提取回收率为98.2%~110.3%; 对水果饮料中罗丹明B的提取回收率为94.6%~102.2%; 对红酒中罗丹明B的提取回收率为90.4%~104.6%. 该方法的线性范围为1~100 ng/mL(ng/g), 相对标准偏差为2.3%~9.0%. 该方法灵敏度高、 选择性好, 可用于干辣椒、 水果饮料及红酒中罗丹明B的定量分析.  相似文献   

11.
建立了血液样本中8种苯二氮卓类药物的高效液相色谱-三重四极杆复合线性离子阱质谱(QTRAP HPLC-MS/MS)检测方法。血液样本经乙腈沉淀蛋白法处理,离心取上清液,过滤后采用分段多反应监测结合信息依赖性采集与增强离子扫描(sMRM-IDA-EPI)模式分析,结合EPI二级谱库检索确证可疑检出物,以sMRM数据采用外标法定量检测。8种苯二氮卓类药物在0.5~50 ng/mL范围内线性关系良好(r>0.998);检出限为0.01~0.10 ng/mL,定量下限为0.10~0.25 ng/mL;化合物在1.0、5.0、20 ng/mL 3个加标水平下的回收率为79.3%~112%,基质效应为79.8%~97.2%,相对标准偏差为4.3%~11%。该方法操作简便,结果准确,适用于中毒患者病情的快速确诊与评估,可为医疗急救与中毒检测提供技术支持。  相似文献   

12.
A liquid chromatography/mass spectrometry method for simultaneous determination of paracetamol and dextropropoxyphene in human plasma is described. Paracetamol and dextropropoxyphene, together with their internal standards (tolbutamide and pyrroliphene), were extracted from 0.5 mL of plasma using solid-phase extraction. The chromatography was performed using a Thermo Hypersil APS-2 Amino column (250 mm x 4.6 mm, 5 microm) with a mobile phase consisting of acetonitrile and 0.4% glacial acetic acid in water (20:80). The total run time was 6 min for each sample. The triple-quadrupole mass spectrometer was operated in both positive (for detection of dextropropoxyphene and its IS pyrroliphene) and negative (for detection of paracetamol and its IS tolbutamide) modes using a polarity-switching technique. Multiple reaction monitoring was used for quantification. The method was linear over the concentration range of 0.1-20 microg/mL for paracetamol and 0.5-80 ng/mL for dextropropoxyphene. The intra- and inter-day precision were less than 10%, and the accuracy ranged from 92.2-110.9%. The lower limits of quantification were 0.1 microg/mL for paracetamol and 0.5 ng/mL for dextropropoxyphene. The present method provides a robust, fast and sensitive analytical tool for both paracetamol and dextropropoxyphene, and has been successfully applied to a clinical bioequivalence study in 14 subjects.  相似文献   

13.
建立了同时检测动物血浆中黄曲霉毒素B1等21种霉菌毒素或其代谢物残留的液相色谱-串联质谱方法.动物血浆样品中加入0.1%甲酸-乙腈溶液、NaCl和无水MgSO4进行萃取,无水MgSO4和C18,PSA,A-AL对提取液进行脱水净化,经浓缩、复溶和离心后,再进行测定.采用反相C18色谱柱分离,以0.1%甲酸-0.5 mmol/L乙酸铵溶液和0.1%甲酸-甲醇溶液作为流动相进行梯度洗脱,采用电喷雾离子源(ESI)多反应监测离子模式(MRM)进行检测,基质标准曲线外标法进行定量分析,线性范围在0.05 ~ 100 ng/mL之间,方法的定量限为0.05 ~0.5 ng/mL.在高、中、低3个添加浓度水平下,21种霉菌毒素的平均回收率为62.0% ~ 116.4%,相对标准偏差小于19%.  相似文献   

14.
采用固相支撑液液萃取-超高效液相色谱-串联质谱(SLE-UPLC-MS/MS)技术建立了生物样本血液、尿液和肝组织中地高辛(DG)及其3种代谢物的分析方法。生物样本经匀浆、蛋白沉淀后,通过含有硅藻土的固相支撑液液萃取(SLE)柱净化富集,经洗脱、定容后进行LC-MS/MS分析。结果表明,血液基质中,地高辛在0.1~100 ng/mL浓度范围内线性关系良好;肝脏和尿液基质中,地高辛在0.2~100 ng/mL浓度范围内线性关系良好,地高辛的3种代谢物在0.5~100 ng/mL浓度范围内线性关系良好,3个浓度水平(10, 50和100 ng/mL)的加标回收率为60.5%~95.6%,基质效应80.7%~113.6%,日内、日间相对标准偏差(RSD)均小于13%,检出限为0.1~0.5 ng/mL。所建立的方法可用于生物样本中地高辛及其代谢物的定性定量分析。  相似文献   

15.
A high performance liquid chromatographic-mass spectrometric (LC/MS) assay was developed and validated for the determination of BMS-204352 in dog K(3)EDTA plasma. A 0.5 mL aliquot of control plasma was spiked with BMS-204352 and internal standard (IS) and buffered with 1 mL of 5 mM ammonium acetate. The mixture was then extracted with 3 mL of toluene. After separation and evaporation of the organic phase to dryness using nitrogen at 40 degrees C, the residue was reconstituted in the mobile phase and 25 microL of the sample were injected onto a Hypersil C(18) column (2 x 50 mm; 3 microm) at a flow rate of 0.5 mL/min. The mobile phase was consisted of two solvent mixtures (A and B). Solvent A was composed of 5 mM ammonium acetate and 0.1% triethylamine in 75:25 v/v water:methanol, pH adjusted to 5.5 with glacial acetic acid, and solvent B was 5 mM ammonium acetate in methanol. A linear gradient system was used to elute the analytes. The mass spectrometer was programmed to admit the de-protonated molecules at m/z 352.7 (IS) and m/z 357.9 (BMS-204352). Standard curves of BMS-204352 were linear (r(2) > or = 0.998) over the concentration range of 0.5-1000 ng/mL. The mean predicted quality control (QC) concentrations deviated less than 5.1% from the corresponding nominal values (ie 4, 80, 400 and 2000 ng/mL); the within- and between-assay precision of the assay were within 5.5% relative standard deviation. Stability of BMS-204352 was confirmed after at least three freeze/thaw cycles and BMS-204532 was stable in dog plasma when stored frozen at or below -20 degrees C for at least 16 weeks in spiked QC samples and for at least 4 1/2 weeks for in vivo study samples. BMS-204352 and IS were stable in the injection solvent at room temperature for at least 24 h. The assay was applied to delineate the pharmacokinetic disposition of BMS-204352 in dogs following a single intravenous dose administration. In conclusion, the assay is accurate, precise, specific, sensitive and reproducible for the pharmacokinetic analysis of BMS-204532 in dog plasma.  相似文献   

16.
A sensitive and selective high-performance liquid chromatography-positive ion electrospray tandem mass spectrometry method was developed and validated for the quantification of amisulpride in 100 microL of human plasma. Following liquid-liquid extraction, the analytes were separated using an isocratic mobile phase on a reverse-phase column and analyzed by MS/MS in the multiple reaction monitoring mode using the respective (M + H)(+) ions, m/z 370-242 for amisulpride and m/z 341-112 for the internal standard. The assay exhibited a linear dynamic range with a lower range of 0.1-100 ng/mL and a higher range of 1-500 ng/mL of amisulpride in human plasma. The lower limit of quantification was 0.1 ng/mL with a relative standard deviation of less than 10%. Acceptable precision and accuracy were obtained for both linearity ranges. A run time of 2.0 min for each sample made it possible to analyze more than 275 human plasma samples per day. The validated method has been successfully used to analyze plasma samples for application in pharmacokinetic studies.  相似文献   

17.
A high performance liquid chromatographic method for the measurement of bemoradan levels in plasma/serum is described. This method uses Varian's AASP (Varian Associates, Sunnyvale, CA, USA), a semi-automatic liquid/solid extraction sample preparation system. It requires only small volumes of plasma/serum samples (0.2-1 mL) and needs no organic solvent for sample preparation. The mean recovery of bemoradan at plasma or serum concentrations of 0.5-100 ng/mL is 82%. The assay has a detection limit of 0.5 ng/mL (when 1 mL of plasma/serum is used) and is linear in the concentration range 0.5-500 ng/mL.  相似文献   

18.
Automated online SPE‐HPLC‐MS was established for the determination of deca‐bromodiphenyl ether in human serum. The online SPE with large volume injection was utilized to enhance the sensitivity. Online SPE with dilution line greatly decreased matrices effect, which enabled serum samples to be injected directly into pre‐column. Washing line was designed for the system to solve the serious residual phenomenon and reduce the risk of sample wastage and contamination. Under the optimized conditions, the linear of the method was in the range 0.1–10 ng/mL with the LOD of 0.026 ng/mL. The recoveries of serum samples spiked with deca‐bromodiphenyl ether at 0.5 ng/mL was in the range from 83.30 to 102.7% with RSD in interday less than 8.67%. The satisfactory results demonstrated that the method of online sample pretreatment and cleanup recycle were reliable for human serum analysis.  相似文献   

19.
A selective method using three-phase liquid-phase microextraction (LPME) in conjunction with LC-MS-MS was devised for the enantioselective determination of chloroquine and its n-dealkylated metabolites in plasma samples. After alkalinization of the samples, the analytes were extracted into n-octanol immobilized in the pores of a polypropylene hollow fiber membrane and back extracted into the acidic acceptor phase (0.1 M TFA) filled into the lumen of the hollow fiber. Following LPME, the analytes were resolved on a Chirobiotic V column using methanol/ACN/glacial acetic acid/diethylamine (90:10:0.5:0.5 by volume) as the mobile phase. The MS detection was carried out using multiple reaction monitoring with ESI in the positive ion mode. The optimized LPME method yielded extraction recoveries ranging from 28 to 66%. The method was linear over 5-500 ng/mL and precision (RSD) and accuracy (relative error) values were below 15% for all analytes. The developed method was applied to the determination of the analytes in rat plasma samples after oral administration of the racemic drug.  相似文献   

20.
林强  杨超  李美丽  王佳  侯瀚然  邵兵  牛宇敏 《色谱》2023,41(3):274-280
人体生物基质中麻痹性贝类毒素的检测对其引起的食物中毒诊断和救治具有重要意义。研究建立了超高效液相色谱-串联质谱法测定血浆、尿液中14种麻痹性贝类毒素的分析方法。实验比较了不同固相萃取柱的影响,优化了前处理条件和色谱条件,血浆样品采用0.2 mL水、0.4 mL甲醇、0.6 mL乙腈提取后直接上机测定,尿液样品采用0.2 mL水、0.4 mL甲醇、0.6 mL乙腈提取,聚酰胺(PA)固相萃取柱净化后上机测定。采用Poroshell 120 HILIC-Z色谱柱(100 mm×2.1 mm,2.7μm)对14种贝类毒素进行分离,流动相为含0.1%(v/v)甲酸的5 mmoL/L甲酸铵缓冲溶液和0.1%(v/v)甲酸乙腈溶液,流速为0.50 mL/min。在电喷雾模式(ESI)下进行正负离子扫描,采用多反应监测(MRM)模式检测,外标法定量。结果表明,对于血浆和尿液样品,14种贝类毒素分别在0.24~84.06 ng/mL范围内线性关系良好,相关系数均大于0.995。尿液检测的定量限为4.80~34.40 ng/mL,血浆检测的定量限为1.68~12.04 ng/mL。尿液和血浆样品在1、2和10倍定量限加标水平下平均回收率为70.4%~123.4%,日内精密度为2.3%~19.1%,日间精密度为4.0%~16.2%。应用建立的方法对腹腔注射14种贝类毒素小鼠血浆和尿液进行测定,20份血浆样本中检出含量分别为19.40~55.60μg/L和8.75~13.86μg/L。该方法操作简便,样品取样量少,方法灵敏度高,适用于血浆和尿液中麻痹性贝类毒素的快速检测。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号