This paper reports a system for three-dimensional electrochromatography in a chip format. The steps involved included trypsin digestion, copper(II)-immobilized metal affinity chromatography [Cu(II)-IMAC] selection of histidine-containing peptides, and reversed-phase capillary electrochromatography of the selected peptides. Trypsin digestion and affinity chromatography were achieved in particle-based columns with a microfabricated frit whereas reversed-phase separations were executed on a column of collocated monolithic support structures. Column frits were designed to maintain constant cross sectional area and path length in all channels and to retain particles down to a size of 3 microm. Cu(II)-IMAC selection of histidine-containing peptides from standard peptide mixtures and protein digests followed by reversed-phase chromatography of the selected peptides was demonstrated in the electrochromatography mode. The possibility to run a comprehensive proteomic analysis by combining trypsin digestion, affinity selection, and a reversed-phase separation on chips was shown using fluorescein isothiocyanate-labeled bovine serum albumin as an example.  相似文献   

2.
This paper describes a procedure for quantitative proteomics that selects peptides containing both cysteine and histidine residues from tryptic digests of cell lysates. Cysteine-containing peptides were selected first by covalent chromatography using thiol disulfide exchange. Following the release of cysteine-containing peptides from the covalent chromatography column with reductive cleavage, histidine-containing peptides were captured by passage through an immobilized metal affinity chromatography column loaded with copper. Quantification was achieved in a four-step process involving (i) differential labeling of control and experimental samples with isotopically differing forms of succinic anhydride, (ii) mixing the two globally labeled samples, (iii) fractionating the labeled peptides by reversed-phase liquid chromatography, and (iv) determining the isotope ratio in individual peptides by mass spectrometry. The results of these studies indicate that by selecting peptides containing both cysteine and histidine, the complexity of protein digests could be substantially reduced. Up-regulated proteins from plasmid bearing Escherichia coli that had been induced with isopropyl beta-thiogalacto-pyranoside were identified and quantified by the global internal standard technology (GIST) described above. Database searches were greatly simplified because the number of possible peptide candidates was reduced more than 95%.  相似文献   

3.
An on-line affinity selection method using a polymeric monolithic support is proposed for the retention of histidine-containing peptides and their subsequent separation by capillary zone electrophoresis (CZE). Monolithic capillary columns were prepared in fused-silica capillaries of 150 mum inner diameter (ID) by ionizing radiation-initiated in situ polymerization and cross-linking of diethylene glycol dimethacrylate and glycidyl methacrylate, and chemically modified with iminodiacetic acid (IDA) and copper ion. Monolithic microextractors were coupled on-line near the inlet of the separation capillary (fused-silica capillary, 75 mum ID x 28 cm from the microextractor to the detector). Model peptide mixtures of histidine-containing and histidine-noncontaining peptides were assessed. Peptides were released from the sorbent by a 5 mM imidazole solution and then separated by CZE with ultraviolet detection. Relative standard deviation values for migration times and corrected peak areas were found to be lower than 5.8 and 10.5%, respectively. IDA-Cu(II) ion modified monolithic microextractors showed a chromatographic behavior and could be reused at least 25 times. The use of monolithic supports proved to be an advantageous alternative to packed particles for the preparation of microextractors.  相似文献   

4.
Zhang L  Zhang L  Zhang W  Zhang Y 《Electrophoresis》2005,26(11):2172-2178
An iminodiacetic acid (IDA)-type adsorbent is prepared at the one end of a capillary by covalently bonding IDA to the monolithic rods of macroporous poly(glycidyl methacrylate-co-ethylene dimethacrylate). Cu(II) is later introduced to the support via the interaction with IDA. By this means, polymer monolithic immobilized metal affinity chromatography (IMAC) materials are prepared. With such a column, IMAC for on-line concentration and capillary electrophoresis (CE) for the subsequent analysis are hyphenated for the analysis of peptides and proteins. The reproducibility of such a column has been proved good with relative standard deviations (RSDs) of dead time of less than 5% for injection-to-injection and 12% for column-to-column (n = 3). Through application on the analysis of standard peptides and real protein samples, such a technique has shown promising in proteome study.  相似文献   

5.
Protein phosphorylation regulates many aspects of cellular function, including cell proliferation, migration, and signal transduction. An efficient strategy to isolate phosphopeptides from a pool of unphosphorylated peptides is essential to global characterization using mass spectrometry. We describe an approach employing isotope tagging reagents for relative and absolute quantification (iTRAQ) labeling to compare quantitatively commercial and prototypal immobilized metal affinity chelate (IMAC) and metal oxide resins. Results indicate a prototype iron chelate resin coupled to magnetic beads outperforms either the Ga(3+)-coupled analog, Fe(3+), or Ga(3+)-loaded, iminodiacetic acid (IDA)-coated magnetic particles, Ga(3+)-loaded Captivate beads, Fe(3+)-loaded Poros 20MC, or zirconium-coated ProteoExtract magnetic beads. For example, compared with Poros 20MC, the magnetic metal chelate (MMC) studied here improved phosphopeptide recovery by 20% and exhibited 60% less contamination from unphosphorylated peptides. With respect to efficiency and contamination, MMC performed as well as prototypal magnetic metal oxide-coated (TiO(2)) beads (MMO) or TiO(2) chromatographic spheres, even if the latter were used with 2,5-dihydroxybenzoic acid (DHB) procedures. Thus far, the sensitivity of the new prototypes reaches 50 fmol, which is comparable to TiO(2) spheres. In an exploration of natural proteomes, tryptic (phospho)peptides captured from stable isotopic labeling with amino acids in cell culture (SILAC)-labeled immunocomplexes following EGF-treatment of 5 x 10(7) HeLa cells were sufficient to quantify stimulated response of over 60 proteins and identify 20 specific phosphorylation sites.  相似文献   

6.
Cation exchange chromatography using conventional resins, having either diffusive or perfusive flow paths, operated in bind-elute mode has been commonly employed in monoclonal antibody (MAb) purification processes. In this study, the performance of diffusive and perfusive cation exchange resins (SP-Sepharose FF (SPSFF) and Poros 50HS) and a convective cation exchange membrane (Mustang S) and monolith (SO(3) Monolith) were compared. All matrices were utilized in an isocratic state under typical binding conditions with an antibody load of up to 1000 g/L of chromatographic matrix. The dynamic binding capacity of the cation exchange resins is typically below 100 g/L resin, so they were loaded beyond the point of anticipated MAb break through. All of the matrices performed similarly in that they effectively retained host cell protein and DNA during the loading and wash steps, while antibody flowed through each matrix after its dynamic binding capacity was reached. The matrices differed, though, in that conventional diffusive and perfusive chromatographic resins (SPSFF and Poros 50HS) demonstrated a higher binding capacity for high molecular weight species (HMW) than convective flow matrices (membrane and monolith); Poros 50HS displayed the highest HMW binding capacity. Further exploration of the conventional chromatographic resins in an isocratic overloaded mode demonstrated that the impurity binding capacity was well maintained on Poros 50HS, but not on SPSFF, when the operating flow rate was as high as 36 column volumes per hour. Host cell protein and HMW removal by Poros 50HS was affected by altering the loading conductivity. A higher percentage of host cell protein removal was achieved at a low conductivity of 3 mS/cm. HMW binding capacity was optimized at 5 mS/cm. Our data from runs on Poros 50HS resin also showed that leached protein A and cell culture additive such as gentamicin were able to be removed under the isocratic overloaded condition. Lastly, a MAb purification process employing protein A affinity chromatography, isocratic overloaded cation exchange chromatography using Poros 50HS and anion exchange chromatography using QSFF in flow through mode was compared with the MAb's commercial manufacturing process, which consisted of protein A affinity chromatography, cation exchange chromatography using SPSFF in bind-elute mode and anion exchange chromatography using QSFF in flow through mode. Comparable step yield and impurity clearance were obtained by the two processes.  相似文献   

7.
We prepared iminodiacetic acid (IDA)-modified and Cu(II)-IDA-modified capillaries through polymerization of N-(vinylbenzylimino) diacetic acid. The fundamental performance of these capillaries was examined in capillary liquid chromatography (LC) and immobilized metal chelate affinity capillary electrophoresis (IMACE). Copper(II), cobalt(II), and hematin were detected at different retention times by means of capillary LC with a chemiluminescence detector, during which the IDA-modified capillary was used. The difference in the retention times was attributed to the difference in the interaction between metal ions or complex and IDA moieties on the inner wall of the capillary. In addition, human serum albumin (HSA) and human serum gamma-globulin (HgammaG) were separated and detected using IMACE with an absorption detector, during which the Cu(II)-IDA-modified capillary was used. The separation of HSA and HgammaG was achieved through the interaction between proteins and Cu(II) chelate moieties on the inner wall of this capillary.  相似文献   

8.
This preliminary investigation tests the premise that biologically relevant (1) peptide-metal ion interactions, and (2) metal ion-dependent macromolecular recognition events (e.g., peptide-peptide interactions) may be modeled by biomimetic affinity chromatography. Divinylsulfone-activated agarose (6%) was used to immobilize three different synthetic peptides representing metal-binding protein surface domains from the human plasma metal transport protein histidine-rich glycoprotein (HRG). The synthetic peptides represented 1-3 multiple repeat units of the 5-residue sequence (Gly-His-His-Pro-His) found in the C-terminal of HRG. By frontal analyses, immobilized HRG peptides of the type (GHHPH)nG, where n = 1-3, were each found to have a similar binding capacity for both Cu(II) ions and Zn(II) ions (31-38 mumol/ml gel). The metal ion-dependent interaction of a variety of model peptides with each of the immobilized HRG peptide affinity columns demonstrated differences in selectivity despite the similar internal sequence homology and metal ion binding capacity. The immobilized 11-residue HRG peptide was loaded with Cu(II) ions and used to demonstrate selective adsorption and isolation of proteins from human plasma. These results suggest that immobilized metal-binding peptides selected from known solvent-exposed protein surface metal-binding domains may be useful model systems to evaluate the specificity of biologically relevant metal ion-dependent interaction and transfer events in vitro.  相似文献   

9.
Several commercial immobilized metal affinity chromatography sorbents were evaluated in this study for the analysis of two small peptide fragments of the amyloid β‐protein (Aβ) (Aβ(1–15) and Aβ(10–20) peptides) by on‐line immobilized metal affinity SPE‐CE (IMA‐SPE‐CE). The performance of a nickel metal ion (Ni(II)) sorbent based on nitrilotriacetic acid as a chelating agent was significantly better than two copper metal ion (Cu(II)) sorbents based on iminodiacetic acid. A BGE of 25 mM phosphate (pH 7.4) and an eluent of 50 mM imidazole (in BGE) yielded a 25‐fold and 5‐fold decrease in the LODs by IMA‐SPE‐CE‐UV for Aβ(1–15) and Aβ(10–20) peptides (0.1 and 0.5 μg/mL, respectively) with regard to CE‐UV (2.5 μg/mL for both peptides). The phosphate BGE was also used in IMA‐SPE‐CE‐MS, but the eluent needed to be substituted by a 0.5% HAc v/v solution. Under optimum preconcentration and detection conditions, reproducibility of peak areas and migration times was acceptable (23.2 and 12.0%RSD, respectively). The method was more sensitive for Aβ(10–20) peptide, which could be detected until 0.25 μg/mL. Linearity for Aβ(10–20) peptide was good in a narrow concentration range (0.25–2.5 μg/mL, R2 = 0.93). Lastly, the potential of the optimized Ni(II)‐IMA‐SPE‐CE‐MS method for the analysis of amyloid peptides in biological fluids was evaluated by analyzing spiked plasma and serum samples.  相似文献   

10.
Carbohydrate-binding peptides of several anti-H(O) leguminous lectins were obtained from endoproteinase Asp-N or Lys-C digests of L-fucose-binding Lotus tetragonolobus lectin (LTA) and Ulex europeus lectin I (UEA-I) and from that of a di-N-acetylchitobiose-binding Ulex europeus lectin II (UEA-II) by affinity chromatography on columns of Fuc-Gel (for LTA and UEA-I) and on a column of a mixture of several oligomers of N-acetyl-D-glucosamine (GlcNAc) coupled to Sepharose 4B (GlcNAc oligomer-Sepharose 4B) (for UEA-II). These peptides were retained on the Fuc-Gel or GlcNAc oligomer-Sepharose 4B column and were presumed to have an affinity for the columns. The amino acid sequences of the retarded peptides were determined using a protein sequencer.  相似文献   

11.
唐晋滨  黄骏雄 《化学学报》1996,54(4):392-397
本实验采用非线性色谱的展开方式之一-超载洗脱, 在普通的分析型离子交换柱TSK Gel-5PW (Φ7.5×75mm)上, 一次进样蛋白质混合样150mg, 成功地进行了溶菌酶的分离纯化, 回收率达90%。收集的馏份经透析和冰冻干燥后,通过高效毛细管电泳(HPCE)测定纯度, 得到了满意的结果, 活性回收率达88%。  相似文献   

12.
This paper addresses the issue of automating the multidimensional chromatographic, signature peptide approach to proteomics. Peptides were automatically reduced and alkylated in the autosampler of the instrument. Trypsin digestion of all proteins in the sample was then executed on an immobilized enzyme column and the digest directly transferred to an affinity chromatography column. Although a wide variety of affinity columns may be used, the specific column used in this case was a Ga(III) loaded immobilized metal affinity chromatography (IMAC) column. Ga(III)-IMAC is known to select phosphorylated peptides. Phosphorylated peptides selected by the affinity column from tryptic digests of milk were automatically transferred to a reversed-phase liquid chromatography (RPLC) column. Further fractionation of tryptic peptides on the RPLC column was achieved with linear solvent gradient elution. Effluent from the RPLC column was electrosprayed into a time-of-flight mass spectrometer. The entire process was controlled by software in the liquid chromatograph. With slight modification, it is possible to add multiple columns in parallel at any of the single column positions to further increase throughput. Total analysis time in the tandem column mode of operation was under 2 h.  相似文献   

13.
通过在肽段的N端引入磺酸基,从而使含组氨酸的肽段与其他肽段在pH<3.0的条件下产生电荷差异,建立了一种基于强阳离子交换色谱(SCX)结合生物质谱富集鉴定含组氨酸肽段的方法,并以含有组氨酸的标准蛋白质为模型,进行了方法学考察。结果表明,经N端磺酸化后,含组氨酸的肽段能有效地被阳离子交换色谱富集,且在肽的N端引入磺酸基促进了肽的裂解,使之产生简单而信息丰富的二级质谱图,从而得到完美的质谱鉴定结果。这说明磺化修饰结合强阳离子交换色谱用于含组氨酸肽段的富集鉴定是可行的,且具有在蛋白质组研究中应用的潜力。  相似文献   

14.
Abstract

Two types of high performance aqueous size exclusion columns have recently been developed, one a rigid spherical silica-based packing containing a new hydrophilic bonded phase (MicroPak TSK Gel Type SW) and the other an organic-based, semi-rigid gel (MicroPak TSK Gel Type PW). Characteristics of MicroPak TSK SW and PW columns were compared to other commercially available aqueous SEC columns packed with similar supports. Chromatographic performance of prepacked columns containing microparticulate support materials were compared for exclusion separations of water-soluble organic polymers, biopolymers, and small water-soluble oligomers. Amino acid probes were used to investigate non-exclusion effects of MicroPak TSK SW and PW columns.  相似文献   

15.
Silica particles of different porosity were functionalised with iminodiacetic acid (IDA) and loaded with Fe(III) to yield immobilised metal affinity chromatography stationary phases (Fe(III)-IDA-silica) for phosphopeptide enrichment. The elution step of bound phosphopeptides was optimised with a 32P radioactive labelled peptide by a comprehensive study. Several elution systems, including phosphate buffers of different pH and concentration and ethylenediaminetetraacetic acid solutions were employed. Furthermore the effect of support porosity on elution behaviour was investigated. Under best conditions recoveries higher than 90% were achieved. A solid-phase extraction (SPE) protocol was developed for fractionation of phosphorylated and non-phosphorylated peptides and desalting of the fractions which is essential for subsequent mass spectrometric analysis by the combination of Fe(III)-IDA-silica and C18-silica particles. The pH of the loading buffer was found to be a critical parameter for the efficiency of the SPE protocol. As tryptic digests of alpha-lactalbumin, lysozyme and ribonuclease A mixed with three synthetic phosphopeptides were fractionated, pH 2.5 provided minimal proportion of unspecific bound peptides when comparing the fractions after mu-LC-electrospray ionization MS separation. The effect of a sample derivatisation reaction (methylation) on the efficiency of phosphopeptide enrichment was further investigated. Blocking carboxylate groups by methyl ester formation totally prevented unspecific interaction with the immobilised Fe(III) ions, but generated partially methylated phosphopeptides that increased the complexity of the phosphorylated fraction.  相似文献   

16.
High-performance affinity chromatography was performed on five ligand-bound columns in an attempt to purify tissue-type plasminogen activator (t-PA), which is a glycoprotein with a high affinity for fibrin and also has two Kringle structures and finger-domain in its molecule. The five columns were concanavalin A-5PW, p-aminobenzamidine-5PW, imidinodiacetic acid-5PW, boric acid-5PW and lysine-5PW. All five were able to rapidly separate t-PA from contaminating proteins, with high resolution and recovery.  相似文献   

17.
Titanium dioxide metal oxide affinity chromatography (TiO2‐MOAC) is widely regarded as being more selective than immobilized metal‐ion affinity chromatography (IMAC) for phosphopeptide enrichment. However, the widespread application of TiO2‐MOAC to biological samples is hampered by conflicting reports as to which experimental conditions are optimal. We have evaluated the performance of TiO2‐MOAC under a wide range of loading and elution conditions. Loading and stringent washing of peptides with strongly acidic solutions ensured highly selective enrichment for phosphopeptides, with minimal carryover of non‐phosphorylated peptides. Contrary to previous reports, the addition of glycolic acid to the loading solution was found to reduce specificity towards phosphopeptides. Base elution in ammonium hydroxide or ammonium phosphate provided optimal specificity and recovery of phosphorylated peptides. In contrast, elution with phosphoric acid gave incomplete recovery of phosphopeptides, whereas inclusion of 2,5‐dihydroxybenzoic acid in the eluant introduced a bias against the recovery of multiply phosphorylated peptides. TiO2‐MOAC was also found to be intolerant of many reagents commonly used as phosphatase inhibitors during protein purification. However, TiO2‐MOAC showed higher specificity than immobilized gallium (Ga3+), immobilized iron (Fe3+), or zirconium dioxide (ZrO2) affinity chromatography for phosphopeptide enrichment. Matrix‐assisted laser desorption/ionization mass spectrometry (MALDI‐MS) was more effective in detecting larger, multiply phosphorylated peptides than liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI‐MS/MS), which was more efficient for smaller, singly phosphorylated peptides. Copyright © 2009 Crown in the right of Canada. Published by John Wiley & Sons, Ltd.  相似文献   

18.
Poly(2-hydroxyethyl methacrylate-co-glycidyl methacrylate) [poly(HEMA-GMA)] cryogel was synthesized by cryopolymerization technique at frozen temperature. Iminodiacetic acid (IDA) was then attached covalently to the cryogel as a chelating agent. Then, poly(HEMA-GMA)-IDA cryogel was chelated with Ni(II) ions and this novel metal affinity support was used for adsorption of urease from its aqueous solution. Urease adsorption experiments were carried out in a continuous system by using a peristaltic pump. Maximum urease adsorption onto poly(HEMA-GMA)-IDA-Ni(II) cryogel was found to be 11.30 mg/g cryogel at pH 5.0 acetate buffer and in 25 °C medium temperature. Urease adsorption capacity decreased with increasing ionic strength and increasing chromatographic flow rate. Adsorption kinetics of urease onto poly(HEMA-GMA)-IDA-Ni(II) cryogel was also investigated and it was found that Langmuir adsorption model is applicable for this adsorption study. This novel immobilized metal affinity chromatography support was used 10 times without any decrease at their adsorption capacity. It was also observed that urease enzyme was repeatedly adsorbed and desorbed without significant lost in enzymatic activity.  相似文献   

19.
An undeca-nuclear nickel substituted POM, namely [Ni(H(2)O)(6)][Ni(11)(PW(9)O(34))(2)(IDA)(3)(en)(2)(Hen)(2)(OH)(6)]·(H(2)O)(7)·(H(2)en)(2) (1) (en = 1,2-ethylenediamine, H(2)IDA = iminodiacetic acid), was synthesized through hydrothermal reaction of Na(6)PW(9)O(34), en, H(2)IDA and NiCl(2)·6H(2)O. Single-crystal structure reveals that 1 can be viewed as Ni(6)PW(9) and Ni(5)PW(9) units linked by a μ(3)-O bridge and two IDA(2-) ligands. Magnetic investigation indicates the presence of dominantly ferrimagnetic interactions within the Ni(11) core. Electrochemistry study shows that 1 displays a stable and reproducible voltammetric graph.  相似文献   

20.
Three hydrophilic immobilized metal affinity chromatographic packings for HPLC have been synthesized by chemical modification of 3.0 µm monodisperse non‐porous poly(glycidyl methacrylate‐co‐ethylenedimethacrylate) (PGMA/EDMA) beads. The retention behavior of proteins on the metal ion chelated columns loaded with copper(II), nickel(II) and zin(II) ion was studied. The effect of pH on the protein retention was investigated on both the naked and metal ion chelated columns in the range from 4.0 to 9.0. Four proteins were quickly separated in 3.0 min with linear gradient elution at a flow rate of 3.0 mL/min by using the synthesized Ni2+‐IDA (iminodiacetic acid) packings. The separation time was shorter than other immobilized metal affinity chromatography reported in the literature. Purification of lysozyme from egg white and trypsin on the commercially available trypsin was performed on the naked‐IDA and Cu2+‐IDA columns, respectively. The purities of the purified trypsin and lysozyme were more than 92% and 95%, respectively.  相似文献   