首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 203 毫秒
1.
The chiral resolving ability of a novel single-isomer cationic β-cyclodextrin (CD), mono-6A-propylammonium-6A-deoxy-β-cyclodextrin chloride (PrAMCD), as a chiral selector in capillary electrophoresis (CE) is reported in this work for the enantioseparation of hydroxy, carboxylic acids and amphoteric analytes. The effect of chiral selector concentration on the resolution was studied. Good resolutions were achieved for hydroxy acids. Optimum resolutions were obtained even at 3.5 mM CD concentration for carboxylic acids. The electrophoretic method showed good linearity and reproducibility in terms of migration times and peak areas, which should make it suitable for routine analysis. In addition, baseline chiral separation of a six-acid mixture was achieved within 20 min. PrAMCD proved to be an effective chiral selector for acidic analytes.  相似文献   

2.
Surfactants such as dioctadecyldimethylammonium bromide (DODAB) form semi-permanent coatings that effectively prevent adsorption of cationic proteins onto the fused silica capillary in capillary electrophoresis (CE). The bilayer coating is generated by flushing the capillary with a 0.1 mM surfactant solution. However, formation of the bilayer is strongly dependent on the coating electrolyte. The effect of counter-ions, electrolyte concentrations and buffer co-ions were monitored based on: the separation of basic model proteins; the adsorption kinetics of DODA+ onto fused silica; and dynamic light scattering (DLS) to determine vesicle size. Low concentrations (≤10.0 mM) and/or weakly associating buffers such as phosphate (pH 3.0), acetate (pH 4.0) and chloride should be used for DODAB coating solutions. Dissolving the surfactant in strongly associating electrolyte, such as phosphate at pH 7.0, results in poor coating of the capillary surface. Effective cationic bilayer coatings are formed if the buffer conditions favor formation of vesicles with diameters < 300 nm. Monitoring turbidity at 400 nm provides a convenient means of verifying vesicle diameter variation of <5 nm; that is, that the coating solution is effective.  相似文献   

3.
In this work, a new physically adsorbed coating for CE is presented. This coating is based on a poly(N,N‐dimethylacrylamide‐co‐4‐(ethyl)‐morpholine methacrylamide) (DMA/MAEM) copolymer synthesized in our laboratory. It is demonstrated that the direction and magnitude of the EOF in CE can be modulated by varying the composition of the DMA/MAEM copolymer and the type and pH of the BGE. Moreover, the DMA/MAEM coating provides %RSDn = 5 values for migration times lower than 0.9% for the same capillary and day, whereas the %RSDn = 25 obtained for the interday assay was lower than 2.9%. The stability of the coating procedure is also tested between capillaries obtaining %RSDn = 15 values lower than 2.9%, demonstrating that this physically adsorbed copolymer gives rise to a stable and reproducible coating in CE. Finally, the usefulness of this new cationic copolymer as CE coating is demonstrated through different applications. Namely, it is demonstrated that the CE separation of basic proteins, nucleotides and organic acids is achieved in a fast and easy way by using the DMA/MAEM coated capillary. The use of fused bare silica capillaries did not allow the separation of these compounds under the same analytical conditions. These results demonstrate that this type of coating in CE provides the option of using BGEs that are useless when utilized together with bare silica capillaries making wider the application and possibilities of this analytical technique.  相似文献   

4.
The reactions of salts of the anion [2-B10H9(N≡CMe)] with aliphatic alcohols ROH (R = C n H2n+1 (n = 1–6) CH2CH2(OEt), Pri, Bui, But, i-C5H11) are studied. These reactions result in hydrolytically stable imidates [2-B10H9{NH=C(OR)Me}]. Their structures were confirmed by the data from mass spectrometry, IR, 1H, 11B, and 13C NMR spectroscopy. The molecular geometry of [2(Z)-B10H9{NH=C(OBu)Me}], which formed in nucleophilic addition reaction of n-butyl alcohol to [2-B10H9(N≡CMe)], was established by X-ray diffraction analysis.  相似文献   

5.
A simple and economical capillary electrophoresis method has been developed for the analysis of four model basic proteins by employing a polymeric ionic liquid (PIL), poly(1-vinyl-3-butylimidazolium) bromide, as the dynamic coating additive. When a small amount of PIL was present in the background electrolyte, a cationic coating on the inner surface of fused-silica capillary was established. These PIL modified capillaries not only generated a stable reversed electroosmotic flow, but also effectively eliminated the wall adsorption of proteins. Several important parameters such as the PIL concentration in the background electrolyte, pH values and concentrations of the background electrolyte were optimized to improve the separation of basic proteins. Consequently, under the optimum conditions, a satisfied separation of basic proteins with peak efficiencies ranging from 247,000 to 540,000 (plates m−1) had been accomplished within 11 min. The run-to-run RSDs (n = 3) of the migration times for the four basic proteins were all less than 0.37%.  相似文献   

6.
Two methods for separation of transferrin (Tf) sialoforms, capillary electrophoresis (CE) and high performance liquid chromatography (HPLC) with conventional UV absorbance detection, have been investigated and compared. First, conditions affecting the separation of the Tf isoforms by capillary zone electrophoresis and HPLC were carefully optimized. The use of 15 mmol L−1 borate buffer (pH 8.4) containing 3 mmol L−1 diaminobutane (DAB) as additive enabled good separation of the Tf isoforms by CE (75 cm×50 μm i.d. fused silica capillary) at 25 kV. In HPLC, a gradient of ammonium acetate (from 0 to 250 mmol L−1 in 45 min) buffered at pH 6 (Tris-HCl) proved suitable for separation of Tf isoforms on a Mono-Q HR 5/5 anion-exchange column. On-line specific detection of the iron associated with the different Tf isoforms, after Fe saturation, by inductively coupled plasma mass spectrometry (ICP–MS) was studied in detail to compare its analytical performance with UV detection. For both CE and HPLC an octapole reaction system (ORS) ICP–MS instrument was used to minimize polyatomic interferences on the 56Fe major isotope. Limits of detection of the different isoforms were in the range of 0.02–0.04 μmol L−1 Tf for HPLC–ICP (ORS)–MS. This hybrid technique proved more selective and reliable detection of transferrin isoforms with 2, 3, 4, 5, and 6 sialic acid residues (S2, S3, S4, S5, and S6) in real serum samples. Interesting results from iron speciation of Tf in serum from healthy individuals and from pregnant women are given.  相似文献   

7.
Compounds (Bu4N)[2-B10H9{NH=C(NHR)CH3}] are obtained by reactions of the tetrabutylammonium salt of the [2-B10H9(N≡CCH3)] anion with aliphatic and aromatic primary amines RNH2 (R = n-C3H7, n-C4H9, cyclo-C5H9, C6H5, cyclo-C6H11, n-C6H13, C7H7, C8H8NH2, C6H4NO2, and C18H37) and identified by IR, ESI/MS, and NMR (1H, 11B, and 13C) spectroscopy. The structures of the amidine-type derivatives [2-B10H9{Z-NH=C(NH-cyclo-C5H9)CH3}] and [2-B10H9{Z-NH=C(NH-C7H7)CH3}] are determined by X-ray diffraction.  相似文献   

8.
《Electrophoresis》2017,38(24):3104-3110
Overcoming proteins adsorption on the inner surface of capillary has attracted increasing attention recently. By using the unique photochemistry reaction of diazoresin (DR), a new covalent capillary coating was prepared on the fused‐silica capillary through layer‐by‐layer self‐assembly of DR with polyglycerol (PG) dendrimer. The separation performance of covalently DR/PG‐dendrimer coated capillary noticeably exceeded the bare capillary and the noncovalently linked DR/PG‐dendrimer capillary. A baseline separation of lysozyme, myoglobin, bovine serum albumin, and ribonuclease A was achieved using CE within 20 min. Besides, the covalently linked DR/PG‐dendrimer coating has the remarkable stability and reproducibility. Especially, compared with the traditional method which use highly toxic and moisture‐sensitive silane coupling agent, this method seems to be a simple and environmental friendly way to prepare the covalently coated capillaries for CE.  相似文献   

9.
CE offers the advantage of flexibility and method development options. It excels in the area of separation of ions, chiral, polar and biological compounds (especially proteins and peptides). Masking the active sites on the inner surface of a bare fused silica capillary wall is often necessary for CE separations of basic compounds, proteins and peptides. The use of capillary surface coating is one of the approaches to prevent the adsorption phenomena and improve the repeatability of migration times and peak areas of these analytes. In this study, new capillary coatings consisting of (i) derivatized polystyrene nanoparticles and (ii) derivatized fullerenes were investigated for the analysis of peptides and protein digest by CE. The coated capillaries showed excellent run‐to‐run and batch‐to‐batch reproducibility (RSD of migration time ≤0.5% for run‐to‐run and ≤9.5% for batch‐to‐batch experiments). Furthermore, the capillaries offer high stability from pH 2.0 to 10.0. The actual potential of the coated capillaries was tested by combining CE with MALDI‐MS for analysing complex samples, such as peptides, whereas the overall performance of the CE‐MALDI‐MS system was investigated by analysing a five‐protein digest mixture. Subsequently, the peak list (peptide mass fingerprint) generated from the mass spectra of each fraction was entered into the Swiss‐Prot database in order to search for matching tryptic fragments using the MASCOT software. The sequence coverage of analysed proteins was between 36 and 68%. The established technology benefits from the synergism of high separation efficiency and the structure selective identification via MS.  相似文献   

10.
From extraction experiments and γ-activity measurements, the extraction constant corresponding to the equilibrium Cs+ (aq) + A (aq) + 1(nb) \rightleftarrows \rightleftarrows 1·Cs+(nb) + A(nb) taking place in the two-phase water–nitrobenzene system (A = picrate, 1 = dibenzo-30-crown-10; aq = aqueous phase, nb = nitrobenzene phase) was evaluated as log K ex (1·Cs+, A) = 4.0 ± 0.1. Further, the stability constant of the 1·Cs+ complex in nitrobenzene saturated with water was calculated for a temperature of 25 °C: log β nb (1·Cs+) = 5.9 ± 0.1. Finally, by using quantum–mechanical DFT calculations, the most probable structure of the resulting cationic complex species 1·Cs+ was derived.  相似文献   

11.
A novel method for the preparation of covalently linked capillary coatings of poly(N‐vinyl aminobutyric acid) (PVAA) obtained from hydrolyzed polyvinylpyrrolidone was demonstrated using photosensitive diazoresin (DR) as a coupling agent. A layer‐by‐layer self‐assembled film of DR and PVAA based on ionic bonding was first fabricated on the inner wall of capillary, then ionic bonding was converted into covalent bonding after treatment with UV light through a unique photochemical reaction of DR. The covalently bonded coatings suppressed protein adsorption on the inner surface of the capillary, and thus a baseline separation of lysozyme, cytochrome c, BSA, amyloglucosidase, and myoglobin was achieved using CE. Compared with bare capillary or noncovalently bonded DR/PVAA coatings, the covalently linked DR/PVAA capillary coatings not only improved the CE separation performance for proteins, but also exhibited good stability and repeatability. Due to the replacement of the highly toxic and moisture‐sensitive silane coupling agent by DR in the covalent coating preparation, this method may provide a green and easy way to make covalently coated capillaries for CE.  相似文献   

12.
A capillary zone electrophoresis method with HP-β-CD as chiral selector was established for the chiral separation of four stereoisomers of 1-(4-hydroxy-3-methoxy)-phenyl-2-[4-(1,2,3-trihydroxy-propyl)-2-methoxy]-phenoxy-1,3-propandiol for the first time, which were isolated from Hydnocarpus annamensis. The effects of chiral selector type and concentration, buffer composition, pH and concentration, and cartridge temperature on the enantioseparation were investigated. A baseline separation of the four stereoisomers was achieved in less than 18 min under the optimized conditions: 40 mmol L−1 Borax–NaOH buffer (pH 10.02) in the presence of 100 mmol L−1 HP-β-CD at 15°C and 30 kV. The experimental results showed that the method by capillary zone electrophoresis for the separation of four stereoisomers is powerful, sensitive and fast, requires less amounts of reagents, and can be employed as a reliable alternative to other methods.  相似文献   

13.
The potentialities of new ionic liquids (ILs) based on choline were evaluated as an electrophoretic medium in capillary electrophoresis for the analysis of alkaline and alkaline earth cations (Li+, K+, Na+, Cs+, Mg2+, Ba2+, Ca2+, and Sr2+) with indirect UV detection. Two types of capillaries were tested: an untreated fused silica and fused silica coated with a film of polyvinylalcohol. The coated capillary proved to be the best adapted for the metal ions studied. Moreover, it appeared that the nature of the ionic liquid anion influenced the baseline stability, and the bis(trifluoromethylsulfonyl) imide (NTf2 ) anion seemed to be the most efficient. These preliminary studies led us to synthesize a new ionic liquid, 2-hydroxy-N,N,N-trimethyl-1-phenylethanaminium NTf2 (phenylcholine NTf2). This liquid was able to act as the running electrolyte and probe, generating the background signal in indirect UV light and consequently simplifying the electrophoretic medium. Excellent baseline stability, good reproducibility, as well as good sensitivity of detection were obtained with this new ionic liquid. Thus, 510,000 plates/meter for Li+ with 40 mM IL were successfully obtained. The optimal concentration of IL was 20 mM with a detection limit ranging from 28 μg L−1 for Li+ to 1,000 μg L−1 for Cs+. This method (phenylcholine NTf2 with polyvinylalcohol capillary) was applied to analyze different commercial source and mineral waters. Finally, the potentiality of this ionic liquid in nonaqueous capillary electrophoresis was explored. The use of phenylcholine NTf2 with a fused silica capillary, in pure methanol medium and in the presence of acetic acid, made it possible to obtain separation selectivity different from that obtained in aqueous medium.  相似文献   

14.
From extraction experiments and γ-activity measurements, the extraction constant corresponding to the equilibrium Cs+(aq) + A(aq) + 1(nb) ⇆ 1·Cs+(nb) + A (nb) taking part in the two-phase water–nitrobenzene system (A = picrate, 1 = hexaarylbenzene-based receptor; aq = aqueous phase, nb = nitrobenzene phase) was evaluated as log K ex (1·Cs+, A) = 2.8 ± 0.1. Further, the stability constant of the hexaarylbenzene-based receptor·Cs+ complex (abbrev. 1·Cs+) in nitrobenzene saturated with water was calculated for a temperature of 25 °C: log β nb (1·Cs+) = 4.7 ± 0.1. By using quantum mechanical DFT calculations, the most probable structure of the 1·Cs+ complex species was solved. In this complex having C 3 symmetry, the cation Cs+ synergistically interacts with the polar ethereal oxygen fence and with the central hydrophobic benzene bottom via cation–π interaction. Finally, the calculated binding energy of the resulting complex 1·Cs+ is −220.0 kJ/mol, confirming relatively high stability of the considered cationic complex species.  相似文献   

15.
Summary Nonaqueous capillary electrophoresis (NACE) has been used to achieve rapid separations of basic drugs. A high electric field was obtained by using short capillaries. Baseline separations of basic drugs, including amphetamines, tropane alkaloids and local anesthetics, were achieved in 1 min by selection of the appropriate organic solvent and electrolyte composition. Thus, high-throughput analyses can be performed. Peak efficiency up to 9154 theoretical plates s−1 was achieved in a separation performed at 923V cm−1. No discernible loss in resolution was observed when a conventional capillary (64.5cm) was replaced by a short (32.5 cm) capillary.  相似文献   

16.
Fast electrophoretic separations in fused silica capillaries (CE) coupled to time-of-flight mass spectrometry (TOF-MS) are presented. CE separations of the model analytes (epinephrine, norepinephrine, dopamine, histidine, and isoproterenol) under conditions of high electric field strengths of up to 1.25 kV cm−1 are completed in 20 s. Coupling of CE with TOF-MS is accomplished using a coaxial sheath liquid electrospray ionization interface. The influence of parameters inherent to the interface and their effects, including suction pressure and dilution, are discussed. In addition to standard capillaries of 75 and 50 μm inner diameter (ID), separations in capillaries with IDs of 25, 15, and 5 μm have been successfully applied to this setup. The analytical performance is compared over this range of capillary dimensions, and both advantages and disadvantages are discussed.  相似文献   

17.
A simple and economical CE method has been developed for the analysis of four model basic proteins by employing N‐methyl‐2‐pyrrolidonium methyl sulfonate ionic liquid (IL) as the dynamic coating material based on the interaction of both between electrostatic attraction and hydrogen bond, and between the organic cations of IL and the inner surface of bare fused‐silica capillary. The N‐methyl‐2‐pyrrolidonium‐based IL modified capillary not only generated a stable suppressed electroosmotic flow, but also effectively eliminated the wall adsorption of proteins. Several important parameters such as the IL concentration, pH values, and concentrations of the background electrolyte were optimized to improve the separation of basic proteins. Consequently, under the optimum separation conditions, a satisfied separation of basic proteins including lysozyme, cytochrome c, ribonuclease A, and α‐chymotrypsinogen A with theoretical plates ranging from 2.09 × 105 to 4.48 × 105 plates/m had been accomplished within 15 min. The proposed method first illustrated the effect of hydrogen bond between coating material and inner capillary surface on the coating, which should be a new strategy to design and select more effective coating materials to form more stable coatings in CE.  相似文献   

18.
Bo T  Wiedmer SK  Riekkola ML 《Electrophoresis》2004,25(12):1784-1791
A phospholipid coating with lysozyme as chiral recognition reagent permeated into the phospholipid membrane was developed for the chiral capillary electrophoretic (CE) separation of D- and L-tryptophan. As a kind of carriers, coated as phospholipid membranes onto the inner wall of a fused-silica capillary, liposomes are able to interact with basic proteins such as lysozyme, which may reside on the surface of the phospholipid membrane or permeate into the middle of the membrane. The interaction results in strong immobilization of lysozyme in the capillary. Coatings prepared with liposomes alone did not allow stable immobilization of lysozyme into the phospholipid membranes, as seen from the poor repeatability of the chiral separation. When 1-(4-iodobutyl)-1,4-dimethylpiperazin-1-ium iodide (M1C4) was applied as a first coating layer in the capillary, the electroosmotic flow (EOF) was effectively suppressed, the phospholipid coating was stabilized, and the lysozyme immobilization was much improved. The liposome composition, the running buffer, and the capillary inner diameter all affected the chiral separation of D- and L-tryptophan. Coating with 4 mM M1C4 and then 1 mM phosphatidylcholine (PC)/phosphatidylserine (PS) (80:20 mol%), with 20 mM (ionic strength) Tris at pH 7.4 as the running buffer, resulted in optimal chiral separation with good separation efficiency and resolution. Since lysozyme was strongly permeated into the membrane of the phospholipids on the capillary surface, the chiral separation of D- and L-tryptophan was achieved without lysozyme in the running buffer. The effects of different coating procedures and separation conditions on separation were evaluated, and the M1C4-liposome and liposome-lysozyme interactions were elucidated. The usefulness of protein immobilized into phospholipid membranes as a chiral selector in CE is demonstrated for the first time.  相似文献   

19.
Oxidation of the cyclohexadienyl complex Fe(η5-C5H5)(1-5-75-6-exo-C5H5-C6H6) (2) by (Ph3C)PF6 (CH2Cl2, from −30 to +20 °C) occurs as two concurrent processes: elimination of an H atom from the cyclohexadienyl ligand and replacement of an H atom in the cyclopentadienyl ring by a CPh3 fragment. A mixture of cationic complexes [Fe(η5-C5H5) (η6-Ph-C5H5]+ (1+) and [Fe(η5-C5H4CPh3) (η6-Ph-C5H5]+ (4+) (4 +) with PF6 anions is obtained. Deprotonation of the mixture of 1+ and 4+ complexes under the action of Bu t OK inm-xylene followed by boiling of the reaction mixture gives phenylferrocene (7) as the product of η66 haptotropic rearrangement. Translated fromIzvestiya Akademii Nauk. Seriya Khimicheskaya, NO. 5, pp. 1045–1047, May, 1997.  相似文献   

20.
A novel and simple coating method was developed by coating bovine serum albumin (BSA) onto the inner surface of a fused-silica capillary, to avoid the adsorption of analytes during CE. The advantage presented here was that the coating process is more simple, fast, stable, and reproducible. The coated capillary avoided the adsorption of analytes onto the inner surface of a fused-silica capillary and might be a promising candidate for separation of complex biological samples with further development. Meanwhile, the efficiencies of the coated capillary were evaluated by EOF, chromatographic peak shape, and theoretical plate number (N m?1) of RNase A. The optimal coating conditions were obtained from the results. The pH value of coating buffer PB was 4.2, the standing time was 12 h at 4 °C, and the coating concentration of BSA was 1.5 mg mL?1. The stability of the coating on the inner wall of the capillary and the reproducibility of the coated capillaries were good. The theoretical plate number values of RNase A were over 1.3 × 105 (N m?1) in the coated capillary. After successive electrophoresis for 48 h using the coated capillary, the RSD values of EOF and the theoretical plate number were 4.14 % and 9.14 %, respectively. In addition, the RSD values of EOF and the theoretical plate number (N m?1) in the coated capillaries were 13.19 % and 8.96 %, respectively. Finally, the coated capillary was successfully applied to separate the mixture of four basic proteins (RNase A, lysozyme, trypsin and myoglobin).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号